Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTSI !,30ANNED BY St Lucie Countv Business & Professional Regulation Ems Home Lag In .User Registration Mot Top. Submit Surcharge Stats & Facts Publications FBC Staff BaS Site Map i Unla I Search j flolida ail Product Approval M USER: Public User Product Approval Menu > Product or Aplilieatlon Search > lotion LJ > Application.Datail RECEIVED FL # FL2569-R14 Application Type Revision Code Version 2017Application Status Approved Comments Archived ❑ Product Manufacturer Soprema, Inc. (Canada) Address/Phone/Email 1640 rue Haggarty I Drummondville, NON -US 00000 (819)478-2400 memathieu@soprema.ca Authorized Signature Marc -Etienne Mathieu imemathieu@soprema.ca I Technical Representative Marc -Etienne Mathieu Address/Phone/Email I j,�1D� 1688Jean-Berchmans-Michaud• r. Jl t_fAT WIJ K I Drummondville, NON -US 00000�t� (819) 478-2400 Ext 3327 memathieu@soprema.ca �C- ST. LUCIE COUNTY BUILDING DIVISION Quality Assurance Representative Jean -Francois Cote, Ph.D. �r- REVIEWED FOR COMPLIANCE Address/Phone/Email i 1640 rue Haggarty REVIE Drummondville DATE a' tKON (888) 811-3145 i jfcote@soprema.ca PLANS AND PERMIT MUST BE JOB SITE OR NO INSPECTIONS) WILL BE MADE Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD, INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. r` Roofing Underlayments Evaluation Report from a Florida Registered Architect or Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Robert J. M. Nieminen PE-59166 UL LLC 07/18/2020 John W. Knezevich, PE G Validation Checklist - Hardcopy Received Standard Year ASTM D1970 2015 ASTM D4798 2011 ASTM D6163 2008 FM 4474 2011 FRSA/TRI April 2012 (04-12) 2012 UL 1897 CONCEALED FASTE4ft OR ATTACHMENTS ARE, THE RESPONSIBILITY OF THE 6QNTRACTOR OR RECORD V Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 02/12/2018 02/14/2018 02/17/2018 04/10/2018 FL # Model, Number or Di scription Name 2569.1 Soprema Roof Self adhering roof underlayments Underlayments - Limits of Use. Installation Instructions Approved for use in HVHZ: No FL2569 R14 II 2018 02 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569- R14.Ddf Approved for use outside HVHZ: Yes Impact.Resistant: N/A Verified By: Robert Nieminen, P.E. PE-59166 by Independent Third Party: Yes Design Pressure: +N/A/-150 Created Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The design pressure Evaluation Reports !FL2569 R14 AE 2018 02 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569- R14. noted herein pertains to underlayment systems used beneath adhesive -set the I Created by Independent Third Party: Yes systems. Refer to ER Section 5.6.4 for details. I--- ck Next Contact Us:: 7601 Blair Stone Raad. Tallahassee FL 32399 Phane: 850-467-1824 The State of Florida is an AA/EEO employer. Coovrlaht 2007-2013 State of Florida.:: Privacy Statement :: Ar2eS51bllity Statement :: Refund Statement Under Florida law, email addrescs are public records. If you do not want your e-mall address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395, -pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please. provide the Department with an email addresslwhlch can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please 1 click ere . Product Approval Accepts: ®®WON 99® I Credit Card Safe ENGINEER EVALUATE. TEST Soprema, Inc. 1640 rue Haggerty Drummondville, Quebec J2C 5P8 Canada (819)478-2400 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 CONSULT CERTIFY Evaluation Report S18010.06.09-1112 FL2569-R14 Date of Issuance: 06/15/2009 Revision 12: 02/12/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction'materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,. P.E. for- use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated folr compliance with the 6 h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall. be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. i CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The EvaluationReport number' preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in Its entirety. INSPECTION: Upon request, a copy of this entire .Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for.inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59266, Florida DCAANE1983 `Sl,1cM. A "•'•;o s, o,:. `a:�,�_�•; • The facsimile seal appearing was authorized by Robert 'kS"• °��•"E9• Nleminen, P.E. on 02/12/201B. This does not serve as an ,,•A /.•�"., .,.,� ` electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will It acquire, a financial interest in any company, manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled) by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not, have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued: 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is,a building code evaluation. Neither NEMOjetc. nor Robert Nieminen, P.E. are; in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: . Underlayment Compliance Statement: Roof Underlayments, Las produced by Soprema, have demonstrated compliance with the following sections of the.e Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Pro a ::.`::. <. Standard :. ear.. 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift 1 UL 1897 2012 1507.2.4/ 1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012 (04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Enti Examination=,� Reference Date. ERD (TST6049) ASTM D1970 / TAS 110 2968.05.04-2 05/14/2004 ERD (TST6049) Physical Properties 2757.02.05 02/03/2005 ERD (TST6049) ASTM D1970 / TAS 110 2974.03.05-2 05/17/2005 ERD (TST6049) Wind Resistance! 2778.07.05 07/15/2005 ERD (TST6049) Wind Resistance, 2779.11.05-R1 04/18/2007 ERD (TST6049) TAS 103 / TAS 110 S7120.11.07-2 11/02/2007 ERD (TST6049) ASTM D1970/TXS 110 S13190.02.09-R1 04/01/2010 ERD (TST6049) ASTM D1970 / TAS 110 S31370.03.10=1-R1 04/07/2010 ERD (TST6049) Physical Properties /Tensile Adhesion S11150.05.10-R1 09/09/2010 ERD (TST6049) Physical Properties / Tensile Adhesion S11150.05.09-112 10/05/2010 ERD (TST6049) ASTM D1970 S37210.11.11 11/09/2011 ERD (TST6049) ASTM D1970 S40540.02.13-1 02/19/2013 ERD (TST6049) Physical Properties/Tensile Adhesion S43530.02.14-1 02/21/2014 ERD (TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-RI 06/07/2017 M-D (CER1592) HVHZ Compliance 15-0508.04 09/24/2015 ICC-ES (EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 PRI (TST5878) Physical Properties SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control Service Confirmation Exp. 07/18/2020 4. PRODDESCRIPTION: 4.1 Lastobond TU HT is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12). 4.2 Lastobond Shield is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch; meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment; available in 3.3 ft x 65 ft rolls; meets ASTM D1970. 4.4• Lastobond Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment; meets ASTM D1970. NEMO ETC, LLC Evaluation Report S18010.06.09-1112 Certificate ofAothorizotlon #32455 67 EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R34 Soprema Roof Underlayments Revision 12: 02/22/2018 Page 2 of 8 110 ONEMO etc. 4.5 . Lastobond Pro HT-N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths, 36 and 45 inch; meets ASTM D1970, 4.6 Lastobond Pro 'HT S is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.7 EnviroShield is a.self-adhering, woven polyethylene surfaced, high temperature,. SBS modified bitumen roof underlayment; meets ASTM D1970. 4.8 Lastobond 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.9 Lastobond Eaves Protection Sheet is a self-adi ering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.10 Lastobond Eco is a self -adhering, glass -mat rel,nforced, sand -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 1 4.11 Lastobond Smooth Seal HT is a self -adhering, glass -mat reinforced, film -surfaced; SBS modified bitumen roof underlayment; meets ASTM D1970. 4.12 RESISTO LB1236 is a self -adhering, glass -mat reinforced, sand-su'rfaced, SBS modified bitumen roof underlayment, with, a 36-inch sheet width; meets ASTM D1970. 4.13 PrimeSource .Grip -Rite Eave. & Valley Protector Is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen. roof underlayment, with a 36-Inch sheet width; meets ASTM D1970: 4.14 RESISTO LB1244 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 44-inch sheet width; meets ASTM D1970. 4.15 Colphene FIR GR is a self -adhering, fiberglass, reinforced, granule -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12). 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any -project on which this Evaluation Report,or previous versions thereof, is/was. used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation'Report is not for use in FBC HVHZ jurisdictions. i 5.3 Fire Classificati.on.is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product.. 5.4 Soprema Roof Underlayments may be usetl with any. prepared roof cover where the product is specifically referenced within FBC approval. documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS I .. Wood or Slate or Asphalt Nail -On -Foam-On . Composite_ Underlayment Shingled` Tile Tile Metal _ Shakes& Composite Slate Shingles LastobondTU HT :::,;:..::... •.. Yes •. <.'. "Yes ;:.' :'..: : • • .- .: Yes. Yes : Yes See..5.5.1 .:. . Lastobond Shield / Pro HT-N / Yes *Tldr'�'�J ��r Noy�� a z 4, c rd No 52, Sri+ j rY IVo r '. Yes Yes RESISTO SA SMOOTH PLY 40 i} 4 Lastobond Shield HT/Pro HT-S' Yes, ,1,. . grtH ¢. ,7i�, _.c Yes ..; :. ; '. 'Yes . Yes; , EnviroShield Yes '' §$.wn:.No° Nid , r,,,, c Yes ,..,. Yes : ` Yes NEMO ETC, U-C Certificate ofAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Soprema Roof Underlayments i Evaluation Report S18010.06.09-Ri2 FL2569-R14 Revision 12: 02/12/2018 Page 3 of 8 f I i ONEMOletc. TABLE 1: ROOF C• Wood or Slate.or Underlayment. Asphalt Nail -On Foarwft Metal Composite Composite - Shingles Tile file Shakes ' Shingles Slate.. Lastobond Eaves Protection Sheet/ i�L4 Yes E r m No m� 4:x�10 Y J1lo S �: Yes Yes Lastobond 195 ,,. ,�r �� ti Lastobond ECO / RESISTO LB1236, drip -Rite Eave &Valle Protector Y / Yes ` Nb� "�u, N ��a� , �z o s es Y01, Yes' RESISTO LB1244 Lastobond Smooth Sea] HT Yes Yes Yes Yes 3 Colphene FR GR Yes Yes y No Yes Yes ' See 5.5 1 5.5.1 "Foam -On Tile" is limited to use of following Adhesive tile adhesives / underlayment combinations. Approval Underloyments Dow TileBondT' FL22525 Lastobond TU HT - ICP Adhesives Polyset° AH-160 FL6332 Lastobond TU HT or Colphene FR GR 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Lastobond Shield, Lastobond Pro HT-N, RE91STO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO 181236, Grip -Rite Pave & Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. Colphene FR GR applied to: ➢ Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete.' 'Note: ➢ While not required over plywood,.OSB or Southern Yellow Pine'substrates, Soprema recommends priming_ with Elastocol Stick or Elastocol"600c ifithe final roof cover is not slated for installation. within 24 hours. ➢ Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.6.2 Bond -to -Insulation: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO L61236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ! ➢ Dens Deck Prime; SECUROCK Gypsum, ' -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on the systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment systel-hrin accordance with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix J or UL1807. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report S18010.06.09-1112 Certificate ofAuthoriration #32455 eH EDITION (2017) FEIC NON-HVHZ EVALUATION FL2569-R34 Soprema Roof Underlayments Revision 12: 02/12/1018 i Page 4 of 8 foNmoletc. 5.6.3 Bond to Mechanically Attached -Base Laver: Lastobond Shield, Lastobond Pro HT-N,.RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO; RESISTO LB1236, Grip -Rite Eave & Valley Protector, ,RESISTO LB1244, Lastobond Smooth Seal HT or -Colphene FR GR applied to: ➢ ASTM D226, Type I or li felt; Sopra-G; Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2612 (04-12). 5.6.4 address wind uplift resistance of all un underlayment forms part of the load -path. that are not addressed in FRSA/TRI April Design, Pressure is the result of testing for v ultimate passing pressure divided by 2 (the Refer to FRSA/TRI April 2012 (04412) or FBC Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not rlayment systems beneath foam -on file systems, where the e following wind uplift limitations apply to underlayment systems .2 (04-12) and are used in foam -on the applications. Maximum d load resistance based on allowable wind loads, and reflects the to 1 margin of safety per FBC 1504:9 has already been applied). 09 for determination of design wind pressures. #1 Maximum Design Pressure = -45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project.- requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol600c Underlayment: Lastobond TU HT or Colphene FR GR„ self -adhered. #3 Maximum Design Pressure = -150.0 asf: Deck: Min. 15/32-inch APA requirements to satisf Deck Preparation:. Plywood shall be thoh sheathing fasteners s projections shall be re Primer: (Optional) RESISTO EX Underlayment: Lastobond TU HT, sel roller.to ensure there laps. !d BCX plywood '(rriay . be installed C-side up) to meet project n of Authority Having Jurisdiction.. ly cleaned to remove, dust and debris that. may inhibit adhesion. All be driven flush with the surface. All sharp splinters and wood )R PRIMER iered, shall be thoroughly roll using hand roller and/or weighted no voids, and ensure there are no voids/bridging at side and end- #4 Maximum Design Pressure =-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.12) spaced 6-inch d.c. at the 4-inch laps and 6-inch'o.c. in three (3); equally spaced rows in the center of the sheet! Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered 5.6.4.1 All other direct -deck, adhered Soprenna underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. NEMO ETC, LLC Evaluation Report S18010.06:09432 Certificate ojAuthoriiadon #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R34 topreina-Roof Underlayments Revision I.2:02/12/2018 Page 5 of 8 I . I ONEMOletc. 5.6.4.2 • For mechanically attached Base Sheet, the maximum design pressure for the.selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional'to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDi, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip=Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield; Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT- S, EnviroShield shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene Flit GR shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlaymerif in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can onlv be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS :lJnde' daymeint : Tile Profile Sta in Method. g ,g Maximum Slope Flat Max:10-tile stack 6:12 Lugged Max. 10-tile stack. 5:12 Max.10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) Lastobond TU HT I Lugged I 'i Colphene FR GR Flat Max. 10-tile stack 5:12 Lugged Max.10-tile stack 6:12 NEMO ETC, LLC Evaluation Report S18010.05.09-1112 CerdJlcate ofAatharization #3z955 67N EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R34 Soprema Roof Underiayments Revision 12: 02/12/2019 Page 6 of 8 6.2 subject to the Limitations set forth in Section 5 lierein.and the specifics. noted below. Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any -dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER (if applicable)., I . 6.3 Lastobond TU H7, Lastobond Shield;.-,Lastobond :Pro: HT-N, RESISTO SA SMOOTH PLY 4% Lastobond :Shield HT; Lastobond Pro HT=S, EnyiroShiefdJastobond Eaves Protection Sheet, Lastobbod 195,.1astobond Eco; Lastobond Smooth Seal HT, RESISTO LB1236,:Grip-Rite Eave & Valley•Protector, RESISTO1131244.or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installetl. - 6.3.2 Non -Tile Applications: While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out lapproximately 10 ft of membrane and peel back the first 3 ft of release film. ' Adhere the exposed part to the substrate and unlroll the remaining membrane as far as possible. Once the entire length of membrane is in placer, peel -off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to ach'ieve'a bond. Horizontal seams should be minimum 3-inches, configured to'shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps shall be sealed using either heat -welding or hot air welding techniques. When installing at slopes above 8:12, Sopremalrecommends back -nailing in the overlap area at the top of the sheet at 12-incho.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place; working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications (Lastobond TU HT or Colohene FR GR only): Reference is made to FRSA/TRI April 2012 (04-1-2) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on the applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12)� Tile shall be loaded and staged in a manner that;prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and Soprema published requirements for tile staging.- . As required. by the Building Official or Authority Having Jurisdiction in 'order to properly evaluate the installation of this product. I NEMO ETC, LLC Evaluation Report S18010.06.09-Ri2 t:ertPJitate ojauthorizatlon #32455 6t" EDITION (2017) FBC NON-HVIiZ EVALUATION FL2569-R34 Soprema Roof Underlayments Revision 12:02/12/2018 Page 7 of 8 i I i . fONEMOjetc. MANUFACTURING PLANTS: Contact the noted QA agency for information oni product locations covered for F.A.C. 61G20-3.QA requirements. The following plants have qualified products under their respective physical properties specifications. Plant Specification Product(sj .. Lastobond Shield, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT; Lastobond Pro HT<N, Lastobond Pro HT-S, Enviro5hield, Lastobond 195, Drummondville, ASTM D1970 Lastobond Eaves Protection Sheet, Lastobond Eco, Lastobond Smooth QC (Canada) Seal.HT, RESISTO.LB1236, PrimeSource Grip -Rite Eave & Valley Protector, RESISTO LB1244 ASTM D1970 & FRSA/TRI 04-12 Colphene FR GR Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco, Wadsworth, OH ASTM D1970 Lastobond Smooth Seal HT, RESISTO LB3236, PrimeSource Grip -Rite Eave & Valley Protector, RESISTO LB1244 ASTM D1970 & FRSA/TR104-12 Lastobond TU HT; Colphene FR GR Lastobond 195, Lastobond Eaves. Protection Sheet,. Lastobond Eco, Gulfport, MS ASTM D1970 Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley Protector, RESISTO LB1244 I 111LUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (314)578=3406; k.chancellor6Ius.ul.com - END OF EI ALUA71ON REPORT - I iI i NEIIAO ETC, LLC Evaluation Report S18010.06.09-R12 certificate ofAuMorfzathn #32455 6m EDITION (2017) FDIC NON-HVHZ EVALUATION F1.2569-11134 Soprema Roof Underlayments Revision 12:02/12/2018 Page 8 of 8