HomeMy WebLinkAboutBOAT LIFT ENGINEERING SPECIFICATIONS° URJ� JCANE BOAT Li i"TS 8 POLE LIFT ENGINEERING SPECIFICATIONS Stainless Steel Plling Mount Bracket With 2-3/8' Bolts Connecting The Bracket To The Assembly. 1-3/8'x3' Stainless Steel Lag Bolts Into Each Side Of Piling DETAIL King Penetration To Be 10' Into The Sand Bottom Or 5' Into The Rock Strata 3 RECOMPINDED PILING SPACEING A B C 40,000# 60' 204' 192' 50,000# 60' 204' 216' 60,000# 60' 216' 216' 5 6 7 8 y. lU 11 1e 141 14 1z) 10 If Lo Lift BDTTDM PULLEY CARPETED BUNK T� DRIVE GUIDE �T DRIVE HOTOR P RING HT MIN. AMOUNT BUNK CABLES �+TR� SHAFT POST WEIGHTS HARDY MATERIAL HP 6 Cap. •I, BEAM BOARD BRACKET BEAM 0 EACH) C4 EAICH) pTY, BRACKETS PILING 13F . (4 EA�(*DS SIZE PILINGS 12'x7',dW �� 5•xl0'x16• HEAVY w1r. 65' )aPI1R 6,x4,�, 54' DW 2.Y PVC Aux 0) STEEL fi061 T6 DIRECT L3 10 STAILESS !0•-12• 40,0000 D1L &uIIING °°' fLA,� u' aoa RE70TTE SMID SCH 40 STAHTDINS WEIGHTS SS 304 MARINE DRIVE STEM 0 EAT)D 4• AL AD.L AL 4 PT- . CONTRM. a EACD ,.UMINXIN W Lam Ir wr WAGE AL D350 (4 EA) ADi D1NE'IFR ST CUSTOI VDaFR I2'x7•x216' WKM 5'x,a'x16• HEAVY 7/)6•x 65' �� 8•x5•s60• 6• n!A E7• PVC ALIW <O STEEL 6061 T6 DIRECT Q STAINLESS w 50,000# DIL RUSHING �' FLAMM SS a04 TaxmE Sam SCH is STA ram UEIGHT5 5s 3" MARINE DRIVE STEEL D Q EADO 7• AL CUSSIMM A0.L AL 4 PT- CGKT DL N �� ALUMINUM M ID' LONG I w 120• WADE AL D350 <4 EN Ant DIAMETER 12'x7'x216' 6T�tlE 5'x1G'x20• HrAVY 7/I6•x 6s' WTW 6• ➢G P3' PVC aLUL <4) siETL 6061 Tfi DIRECT 2 STAOLESS �• 60,000# n� FA15Falfi �L P1.A<AGE �' 3C4 REMOTE SOLID . ST)1 10 STANi®'IS VF3GlITS 304 AR08i _AL DRIVE STEELAINUE 9 !P El1aD S• AL CUSTT,DI AD.L AL o PT- cmlTam a EAOD � la' L6vG l2• LEA' �� �• D500 U W AI � DEAILETER THE WORK SPECIFIED HEREIN HAS BEEN DESIGNED & ALL WORK SHALL BE IN ACCORDANCE WITH STRUCTURAL PROVISIONS OF THE 6th EDITION 2017 FLORIDA BUILDING CODE. NOTE: THIS LIFTING STRUCTURE HAS BEEN DESIGNED TO WITHSTAND WIND LOADS ASSOCIATED WITH WIND SPEEDS OF V,A%= 180 MPH, VAIN = 139 MPH (3 SEC. GUST) EXPOSURE 'D' WITHOUT A BOAT ON THE LIFT PER ASCE 7-10 USING ABOVE GROUND SIGN/WALL METHOD, THE LIFTING STRUCTURE INCLUDING BOAT HAS BEEN DESIGNED TO WITHSTAND WIND SPEEDS OF Wilt=90 MPH IN EXPOSURE 'C' OR 80 MPH IN EXPOSURE V. OWNER RESPONSIBLE TO REMOVE BOAT FROM LIFT DURING WINDSTORM EVENT IN EXCESS VUSU AS CALATED BELOW, PER FBC 3105.5.3 STRUCTURES DESIGNED TO BE READILY REMOVED OR REPOSITIONED DURNING PERIODS OF HIGH WIND VELOCITY SHALL BE POSTED WITH A LEGIBLE AND READILY VISIBLE DECAL OR PAINTED INSTRUCTIONS TO BE THE OWNER OR TENANT TO REMOVE OR REPOSITION THE STRUCTURE OR PART THEREOF DURNING SUCH PERIODS OF TIME AS ARE DESIGNATED BY THE U.S. WEATHER BUREAU AS IS CERTIFICATION OF BOAT LIFT TO EXISTING STRUCTURE AND ALL ELECTRICAL OR MECHANICAL CERTIFICATIONS ARE BY OTHERS; ENGINEER SEAL CERTIFIES ASSEMBLY OF LIFT ONLY. THIS DETAIL IS PREPARED AS A GENERAL NON —SITE SPECIFIC MASTER PLAN SHEET DETAIL TYPICAL FIELD CONDITIONS ARE ASSUMED IN THE DESIGN. WOOD PILES SHALL BE SEASONED WOOD WITH G=0.55 OR BETTER. SHOULD ANY SPECIFIC LOCATION DIFFER FROM THAT SPECIFIED HEREIN, OR STANDARD FIELD CONDITIONS, ADDITIONAL SPECIFIC ENGINEERING AS BE:REQUIRED, AS DETERMINED BY THE BUILDING INSPECTOR=AND PERMITTING.CONTRACTOR: CARE'SHALL BE TAKEN BY CONTRACTOR IN ALL APPLICATIONS OF 'THIS DETAIL AS THIS IS NOT A SITE SPECIFIC DRAWING, IT IS THE RESPONSIBIUTY•'OF OTHERS' TO ENSURE THE INTEGRITY OF INSTALLATION TO THE HOST STRUCTURE. ALUMINUM ' 1 , !'•''' ::i, n I. . , I: l .1 MATERIAL• 6061 T6 ALUMINUM ) 'I ALL WELDS ARE MIN. 1//4- FULL FILLET WELD USING 5556 FILLER ALLOY. ALL-WELDING•MUST. CONFORM:TO,AISC STEEL! CONSTRUCTION MANUAL 13TH ED AS INSPECTED AND ,VERIFIED BY:OTHERS.THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALUMINUM,MEMBERS'FROM"DISSIMILAR'METALS '-TO PREVENT ELECTROLYSIS. FASTENERS 'AL I: NCHDRS TO BE HILTI BRANDIOR"LFli EQUIVALENT. ALL BOLTS SHALL BE;HOT'DIPPED GALVANIZED; 'OR STAINLESS'STEEL & MEET THE REQUIREMENTS OF ASTM A304 WITH HARDENED.WASH,ERS,AND HEX NUTS.,WASHERS,SHgLL BE USED BETWEEN WOOD & SOLTiHEAD,& BETWEEN WOOD •& NUT. r WHERE, GENERIC FASTENERS ARE LABELED IN DETAILS, CAPACITIES SHALL SE'EQUAL TO; OR GREATER THAW HILT] KWIK BOLT II OR RED•HEAQTHRU'BOLTS., EMBEDMENT -DEPTHS SPECIFIED HEREIN ARE DEPTHS INTO SOLID SUBSTRATE AND DO NOT INCLUDE THICKNESS OF STUCCO OR OTHER FINISHES. ALUMINUM MEMBERS IN CONTACT WITH CONCRETE AND WOOD SHALL BE PROTECTED BY "KOPPERS BITUMINOUS PAINT" OR POLYETHYLENE TAPE UHMW (ULTRA HIGH MOLECULAR, . WEIGHT) 11.7 mils (0.30 mm) MIN. TOTAL THICKNESS IN ACCORDANCE WITH CURRENT FLORIDA BUILDING CODE. ALL WELDS PER FLORIDA BUILDING CODE. SPECIALTY ENGINEERING SERVICES & SOLUTIONS INC. HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. SPECIALTY ENGINEERING SERVICES & SOLUTIONS INC. SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE VERIFIED PRIOR TO. CONSTRUCTION. SPECIALTY ENGINEER SERVICES'& SOLUTIONS. SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION ;PRIOR TO MODIFICATION; OF EXISTING( FIELD• CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. 'ENGINEERING SEAL AFFIXED HERETO'VAUDA$ES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. pl. INDCAIKC,,lES, &, SAVES HARMLESS THIS ENGINEER FOR ALL'COSTS & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATi3O:4,'SYSTEM ERECiON & CONSTRUCTION PRACTICES BEYOND, THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES &' FORM DEVIATIONS OF THIS ,PLAN, EXCEPT AS, EXPRESSLY PROVIDED IN. HEREIN, NO CER11FICATION OR AFFIRMATIONS ARE INTENDED. T}iIS' SPECIFiCATION SHEET GOOD ONLY AT THIS NAME AND ADDRESS-- VOID"WITHOUT HURRICANE SEAL OVER NAME _ . NAMEi ADDRESS,,—_L� CITY, STATEI ZIP, HURRICANE- BOAT LIFTS 3301 S,E, Stater Street Stuart, Florida 34997 (77E)-781-255E Fax (772)-781-4854 Revised, 1/15/18 SPECGICATIMS SUBJECT TD CHANGE AT ANY TIME JMFERY C. FRIANT P.E., GATE: Rep; Floddr� Nc,•F';EC060994 SPM0lALTV[ N®1R78ER1NQ , _ e?J(a _ FRV1020 &9OLUIT10l1ojX .-7 _ : 18540 126th TERRACE N. JUPITER, FL 33478 PH: (561) 412-8287 wxw.SESS—incoom In6�,.i3n11wnnin . r;nnc�vaen¢ran, _ .'+' . i11. JJJJ CONOFALED FASTENERS OR ATTACHMgNTS ARE THE RESPONSIBILITY OF THE CONTRAICTOP, OF RECORD 1 5-C7367 ST. LUCRE COUNTY ]3iJILL�E�TO THESE PUNS AND ALL PROPOSED WORK REVIEWED FOR COI RL i ARE SUBJECT TO ANY CORRECTIONS REVIEWED BY REQUIRED BY FIELD INSPECTORS THAT DATE f PLANS AND PERMIT MUST A KEPT 9N JOB MAYBE NECESSARY IN ORDER TO OR NO MPECTION WML =Ea OOMPLY WITH ALL A,PPWCAPO �®019d '` i ISLAND DUNES YACHT CLUB, INC. 8735 S. Ocean Drive Jensen Reach, FL 34957 (772)229-0803 March 15, 2018 Eric Nicholson 8600 S Ocean Drive, PI-I-1 Jensen Beach, Ft. 34957 j Dear Sir/Madam: Please accept this letter as permission to install a boat lift in you slip. Respectfully, j I ROV, Zf/lfftae ra Roy Williams President Indian River County '11). St. Lucie County tl I I I ¢ f 0' 1 b6i. A Ultimate Design 1 I S 1 11 I 1 Wind sr�:,o 99e Vatbaay , 1 st L.! env , Speeds G23a Belcher G.`31a111a a� Risk Category I Buildings l l 1 I - I ' I ore, Are + 1 I 3n E r i 1 Nature of Occupancy 30001 + + 1 , 1 �1 Buildings and other structures that represent a OrangeAve ' A e I low hazard to human life in the event of failure, 7.including but not limited to: 1 1 I rR t I �� �, .� 3 1 a � 1 ,g � , a, _ � t � -. .�1 �9 • Agricultural facilities + + V k 't 1 I + + 1 t F c 1 • Certain temporary facilities + + + 1 l ` i� �l • Minor storage facilities Screen enclosures — _ - 0- - - - - - 1 - ---I - - west tM& r Rd 1 - - x0 f I tk] a I I j City Limits d i C-23 caed r . fk 1 r A A o 1 A i a m of F iv�c1 nd 1 ` jJ I U.:. t a 1•r -d° A 1 ` W E 6 j N ' i 1 betll6oir Ge�N ti b a.;, d • .S . { I tKm -- + 1 m Martin Co anty 1' ? 0 2 4 rizl Cantu 1 �.. 1......_.:....Y.Y.t Miles Martin County Map prepared December 5, 2011 0 Rick ``ao 9aPaFlorida Department of Governor Environmental Protection � Carlos Lopez -Canters Bob Martinez Center Lt. Governor 2600 Blair Stone Road Noah Valenstein Tallahassee, Florida 32399-2400 Secretary Receipt for Submission I i SELF CERTIFICATION FOR A PROJECT AT A PRIVATE, SINGLE-FAMILY RESIDENCE 04/27/2018 Self Certification File No.: 0160206003EE File Name: 8735 S Ocean Dr Ste 2 Jensen Beach, FL 34957 - Self -Certification Modify With Boat Lift (Aquatic Preserves) Dear Ron A. DeGrazia: On, 04/27/2018, you used the Florida Department of Environmental Protection's electronic Self Certification Process to certify compliance with the terms and conditions of the Federal State Programmatic General Permit (SPGP) Self Certification Process for a project at private, single-family residence located at: LAT - Degrees: 27 Minutes: 18 Seconds: 20.2242 LONG - Degrees: -80 Minutes: 13 Seconds: 19.7201 SITE ADDRESS: 8735 S Ocean Dr Ste 2 Jensen Beach, FL 34957 COUNTY: St. Lucie For: Eric Nicholson 8600 S Ocean Drive PH1 Jensen Beach, FL 34957 You have certified that the project you propose to construct at the above location meets all the conditions of the Self -Certification Process. A project that is built in conformance to those conditions (attached for reference) will: 1. Qualify for a regulatory exemption under Section 403.813(1)(b) of the Florida Statutes (F.S.) and Chapter 62-330, Florida Administrative Code (F.A.C.). As such, it is exempt from the need to obtain a DEP Environmental Resource Permit.; 2. Qualify for Consent by Rule or Letter of Consent (as applicable) under Chapter 253, F.S. and Chapter 18-21, F.A.C. (and Chapter 258, F.S. and Chapter 18- 20, F.A.C., if applicable), when the project is located on submerged lands owned by the State of Florida.; i Your Self -Certification is based solely on the information you provided under this process, and applies only to the statutes and rules in effect when your certification was completed. The certification is effective only for the specific project proposed, and only if the project is constructed, operated, and maintained in conformance with all the terms, conditions, and limitations stated in the Self -Certification Process. In addition, any substantial modifications in your plans should be submitted to the Department for review, as changes may result in a permit being required. You have acknowledged that this Self Certification will automatically expire if: 1. Construction of the project is not completed within one year from the self - certification date; 2. site conditions materially change; 3. the terms, conditions, and limitations of the Self Certification are not followed; or 4. the governing statutes or rules are amended before construction of the project. Completion of the Self Certification constitutes your authorization for Department or Corps personnel to enter the property for purposes of inspecting for compliance. Receipt of this Self -Certification constitutes authorization to use sovereignty/state- owned submerged lands, as required by rule 18-21.005, F.A.C. The authorization must be visibly posted duririg all construction activities. In waters that are accessible to manatees, obtain information on your mandatory Manatee Protection sign by clicking here. FEDERAL STATE PROGRAMMATIC GENERAL PERMIT (SPGP) You have certified that the project you propose to construct at the above location meets all the conditions of the SPGP Self -Certification Process and will be built in conformance to those conditions (attached for reference). Your proposed activity as certified is in compliance with the SPGP program. U.S. Army Corps of Engineers (Corps) Specific conditions apply to your project, attached. No further permitting for this activity is required by the Corps. In the event of the transfer of ownership of the property by sale or by any other means, when the structures or work authorized by this SPGP Self -Certification are still in existence at the time the property is transferred, the terms and conditions of this SPGP Self -Certification will continue to be binding on the new owner(s)of the property. Although the construction period for works authorized by Department of the Army permits is finite, the permit itself, with its limitations, does not expire. To validate the transfer of this SPGP Self -Certification and the associated responsibilities associated with compliance with its terms and conditions, the attached transfer of SPGP Self -Certification request must be completed and submitted to the Department at the time. of transfer of ownership. The address is given below on the attached transfer form. This SPGP Self -Certification is based solely on the information you provided under this process, and applies only to the statutes and rules in effect when your certification was completed. You have recognized that your certification is effective only for the specific project proposed, and provided the project is constructed, operated, and maintained in conformance with all the terms, conditions, and limitations stated, in the SPGP Self -Certification Process. This Self -Certification will not apply if any substantial modifications are made to the project. You agree to contact the Department for review of any plans to construct additional structures or to modify the project, as changes may result in a permit being required. You have acknowledged that this Self -Certification will automatically expire if: 1. construction of the project is not completed by midnight, July 25, 2021, unless construction commenced or a contract to construct was executed before July 25, 2021, in which case the time limit for completing the work authorized by the SPGP ends at midnight, July 25, 2022. However, in no case can construction continue for more than one year beyond the Self -Certification date; 2. site conditions materially change; 3. the terms, conditions, and limitations of the Self -Certification are not followed; or 4. the governing statutes or rules are amended before construction of the project. Completion of the Self -Certification, constitutes your authorization for Department or Corps personnel to enter the property for purposes of inspecting for compliance. If you have any questions, please contact your local Department District Office. Contact information can be found at: https://floridadep.gov/water/submerged- lands-environmental-resources-coordination/documents/district-office-contacts. For further information, contact the Corps directly at: http://www.saj.usace.army.mil/Missions/Regulatory.aspx. When referring to your project, please use the SPGP Self -Certification file number listed above. Authority for review - an agreement with the U.S. Army Corps of Engineers entitled Coordination Agreement between the U. S. Army Corps of Engineers (Jacksonville District) and the Florida Department of Environmental Protection State Programmatic General Permit, Section 10 of the Rivers and Harbor Act of 1899 and Section 404 of the Clean Water Act. i i I i i i ADDITIONAL INFORMATION I i This Self -Certification Process does not relieve you from the responsibility of obtaining other permits or authorizations from other agencies (federal, state, Water Management District, or local) that may be required for the project. Failure to obtain all applicable authorizations prior to construction iof the project may result in enforcement. If you have any problems with the attached documents, please call the ERP Coordinator at (850) 245-8495 or by e-mailinglus at ERP eApps(a-dep.state.fl.us. i i Sincerely, Florida Department of Environmental Protection �I •. 0 Island Dunes Country Club Slip #2 Install (8) New Marine Grade Pilings & (1) New Cat 5 - 40,000# Hurricane Cradle Lift * see attached Engineered Specifications IF IsIand ®cartes Country Club Inc 8735 5 Ocean Dr ensew Beach;. FL 34557 N a` w 4 d co YX 0 CD 1.0 00