Loading...
HomeMy WebLinkAboutARCHITECTUAL-ENGINEERING PLANSJ REMODEL # 6485 H2500�M 6601 US HIGHWAY 1 SOUTH PORT ST. LUCIE, FL 34952 r, ■ I r , 11 SPEEDWAY D'T ENON, OH 45323 937-864-3000 ARCHITECTURAL 1 ENGINEERING: 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T I <V, w aan Waft *.1 1tl ieb -wr0 0 Cl HI r10ffl iv C80i.- r y r ram` i ® J, ,ta rtne A' •,ri71.,1 idYfILLLCoUtrS m I 1 l us31 T.yit. "i 4 GacisllSeaul6tu 9awirr fa'-itlOr ,4tst'.nros.?1Nts[F Y �+. 6letnetil?eny SchGfi STORE # 6485 6601 US HIGHWAY 1 SOUTH PORT ST. LUCIE, FL 34952 LOCATION M (NO SCALE) n BUILDING CODE SUMMARY EXISTING BUILDING AREA 2480 S.F. USE 'M' AREA (INCLUDING REST ROOMS ATTENDANT AREA, ALCOVE) 1285 S.F. ACCESSORY STORAGE AREAS & COOLER 642 S.F. USE'B' AREA 553 S.F. OCCUPANT LOAD FACTOR PER COKE 'M' = 30 GROSS 'S' = 300 GROSS 'B' =100 GROSS CALCULATED OCCUPANT LOAD MERCANTILE'M' 1285/30 43 STORAGE'S' 642/300 3 BUSINESS'B' 553/100 6 TOTAL NUMBER OF OCCUPANTS 52 EXITS REQUIRED 2 EXITS PROVIDED 2 BUILDING HT. TO TOP OF ROOF 22'-0" V.I.F. NUMBER OF STORIES 1 USE GROUP (MIXED USE, NON -SEPARATED) M / S / B TYPE OF CONSTRUCTION 5B NOTE: GROSS BUILDING SQUARE FOOTAGE HAS NOT CHANGED FROM EXISTING. ADOPTED CODES THE BUILDING DESIGN SHALL COMPLY WITH THE FOLLOWING CODES: 2010 FLORIDA BUILDING CODE 2010 FLORIDA EXISTING BUILDING CODE 2010 FLORIDA MECHANICAL CODE 2010 FLORIDA PLUMBING CODE 2011 NATIONAL ELECTRICAL CODE 2010 FLORIDA ENERGY CONSERVATION CODE 2014 FIRE PREVENTION CODE - FIFTH EDITION 2010 FLORIDA ACCESSIBILITY CODE SITE SPECIFIC CV COVER SHEET STRUCTURAL S1 FOUNDATION PLAN & SECTIONS S2 STRUCTURAL ROOF FRAMING PLAN S3 STRUCTURAL DETAILS ARCHITECTURAL D1 FLOOR DEMOLITION PLAN D2 CEILING DEMOLITION PLAN Al FLOOR CONSTRUCTION PLAN A2 CEILING CONSTRUCTION PLAN A3 FINISH PLAN & FINISH SCHEDULE A4 ROOF PLAN A4.1 ROOF DETAILS A5 EXTERIOR ELEVATIONS A7 EXTERIOR DETAILS A8 WALK-IN DETAILS EQ1 EQUIPMENT PLANS EQ2 EQUIPMENT SCHEDULE & DETAILS PLUMBING P1 DOMESTIC WATER PLAN P2 SANITARY SYSTEM PLAN P3 PLUMBING SCHEDULES & DETAILS P4 PLUMBING DETAILS MECHANICAL M1 MECHANICAL PLAN M2 HVAC SCHEDULES & DETAILS ELECTRICAL E1 POWER PLAN E2 LIGHTING PLAN E3 COMMUNICATION & SECURITY PLAN E4 PANEL SCHEDULES E5 EQUIPMENT SCHEDULES & SINGLE LINE RISER DIAGRAM SCANNED By St Lucie County al Li � Il- C O -� , � r: } 1 4 STx41C'�SEE 4.1 REAR ThIE:E ?LANE AND ALL PROPOSWi WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY PIELD NSPEC'R[ p Tr :T GdAY BE N£ct96Atity Ire IS M TO COMPLY WITH ALL APPLICABLE CO®ES. ST. LUCIE PLAN R r DATE: MECH DATE: COPY 0 Z 0 7007 DISCOVERY BL DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.CON MAY 222` a d 0 c 0 U 7 r N 0 U m4,w 0GC @'fix m a -0d �yc= 0.r_ �aNWW = N Lo W Q co LU r ¢ C= L W g J _ Cn O U Z) I— I m CD 0 CID EL 19 c STORE O BLDG NOR 6485 1 VERSION OR AFE NO. SCALE: 0 4 DESIGN TEAM DATE DGNR. J. YOUST 05-22.2015 PM./DP. D. TIMMER 05-22.2015 RVR./DP. B. BUZARD 05-22-2015 DRWG. NO. Cv A N 7 C im i C9 m co 59'-10" Y-5" 3" 14'-1 1/2" 3" 11'-3" 3" 14'-2 3/4" 3" 9'-3 3/4" 3" C12 x 20.7 I I I I I I I I I I l I I I I I I 1 I I I 1 I I I I I I I L I I I I I I 1 1 I I I I I I 6_x, 1 01 0 1 01 0 1 o al o 0 q 0 _l I� xl xI xl xl xI xl _o xl _, xl X1 xi xi Ix xl NI x co I 0 m i ;I co 3 o 1 � I co�I co co 0 c1 cap 0 ro 31 � I I I I I I I I t I EXISTING FLOOR I I I I I I 1 I 1 FRAMING, TYP,— I t / \ C10x20 — \ C10x20 \ \ �-- 1 L L I fJ I i I I I 1 I I I I 1 I I I I I I I I I I I I I I I I I I I h I I I I I I I n O O O O O I O O O O O O i N N x x x 1 X I X OI X co x 01 I X x �I x �I x �I x 01 X 01 X 01 xI N J co 01 coI I >�I STRUCTURAL SLAB DEMOLITION L, - AND EXISTING. PIER, G I REPLACEMENT- TYP. SEE DETAILS ON I — S-1, TYP. / C10x20 \ \ \ C10x20 \ \ x N co x 0 O 61 OI of of of OI OI of 0 Lq cm x 1 Ix x 0 0 x co �I x 0 31 x m �I o) xl co �I x 0 �I x co 31 x 0 31 x 0 31 x 0 �I x co C8 x 11.5 13 31 0 I. 1 x co xl 1 I i I I I I I 1 I I I I 1 I I I I I I I I l I I I I C12x20.7 1 0 - FOUNDATION PLAN - DEMOLITION SCALE: 1/4" = 1'-0" 6" MIN., SAW CUT AND REMOVE EXIST. SLAE AND METAL DECK 4" MIN. C/C EXIST. FLOOR BEAMS SPAN VARIES 4" MIN. CHIP CUT EXIST. CONCRETE AND EXPOSE EXISTING MIN. REINFORCING STEEL AT EACH SIDE AND END OF SAW CUT SECTION "DECK ETAL REMAIN 0 TYP. FLOOR FOR PLUMBING INSTALLATION SCALE: 1" = 1'-0" SECTION DETAIL EXIST. W8 BEAM N M MIN. CONCRETE SLAB (F'c = 4,000 PSI MIN.) ON 1 1/2", 22 GA. TYPE'F' METAL DECK. REINFORCE WITH WWF 4X4-W2.9XW2.9. C/C EXIST. FLOOR BEAMS SPAN VARIES NEW METAL DECK TO OVERLAP EXIST. DECK. FASTEN DECK TO SUPPORTS WITH SELF -TAPPING SCREWS #14X3/4" LONG AT 12" O.C. 6" MIN. FASTEN SIDE LAPS WITH TWO (2) #10 SCREWS PER SPAN. GI EXIST. W8 BEAM ®TYP. FLOOR SLAB ON DECK REPLACEMENT DETAIL SCALE. 1" = 1'-0" SECTION DETAIL GENERAL NOTES: • THE CONTRACTOR SHALL CONDUCT ALL OPERATIONS IN STRICT ACCORDANCE WITH THE SAFETY REQUIREMENTS IMPOSED BY THE OWNER AND OSHA. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS GOVERNING THIS WORK. • THIS STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER COMPLETED. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE DEMOLITION PROCEDURES AND SEQUENCES, AND TO INSURE THE STABILITY OF THE STRUCTURE AND ITS COMPONENT PARTS. THIS INCLUDES THE ADDITION OF WHATEVER TEMPORARY BRACING, GUYS, OR TIE -DOWNS THAT MIGHT BE NECESSARY. SUCH MATERIAL IS NOT SHOWN ON DRAWINGS. IF APPLIED, THEY SHALL BE REMOVED AS CONDITIONS PERMIT AND SHALL REMAIN THE CONTRACTOR'S PROPERTY. • THE CONTRACTOR SHALL REMOVE ALL DEBRIS FROM THE OWNER'S PROPERTY AND DISPOSE OF THEM ACCORDING TO LOCAL REGULATIONS. • ALL DEVIATIONS FROM THIS DRAWING SHALL BE SUBMITTED IN WRITTEN FORM TO THE OWNER OR THEIR REPRESENTATIVE FOR APPROVAL. • EXISTING UTILITIES AND ALL OTHER OBSTRUCTIONS TO WORK SHALL BE TEMPORARILY REMOVED BY THE CONTRACTOR AND REINSTALLED (INCLUDING NECESSARY MODIFICATIONS) BY THE CONTRACTOR AFTER COMPLETION OF WORK. • EXCAVATION AND DEMOLITION SHALL PROCEED WITH CARE TO AVOID DAMAGE TO UNKNOWN UNDERGROUND SERVICES. • BACKFILL SHALL BE GRANULAR MATERIAL, FREE FROM CLAY, LOAM, OR PERISHABLE MATERIALS. THE APPROVED GRANULAR . MATERIAL SHALL BE COMPACTED TO A DENSITY EQUIVALENT TO 95% MODIFIED PROCTOR. • CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY THE OWNER BEFORE PROCEEDING IF ANY CONDITIONS ARE NOT / AS SHOWN OR IF EXISTING CONSTRUCTION IS DETERIORATED. • WHEN PATCHING EXISTING SLABS OR SIDEWALKS PROVIDE MATCHING SAW CUT OR TOOLED JOINTS. • COORDINATE STRUCTURAL SLAB DEMOLITION WITH ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. TYP. • STRUCTURAL SLAB DEMOLITION SHOWN IS AN APPROXIMATE LOCATION AND SIZE, ACTUAL DEMOLITION SHALL BE AS NECESSARY TO COMPLETE THE WORK. • CONTRACTOR SHALL PROVIDE DIMENSIONED LOCATIONS OF STRUCTURAL SLAB DEMOLITION AND REPAIR ON THE AS -BUILT DRAWINGS. PLAN NOTES: 1 REFER TO SHEET S-2 FOR GENERAL STRUCTURAL NOTES. 2. ANY CHANGES MADE TO THE DESIGN IDENTIFIED ON THESE DRAWINGS AND/OR ASSOCIATED HALL BE SUBMITTED TO THE ENGINEER/ ARCHITECT F RECORD FOR REVIEW SPECIFICATIONS S S I CT O R GO O AND APPROVAL PRIOR TO MAKING ANY MODIFICATIONS TO THE PROJECT. ANY LIABILITY AS A RESULT OF DESIGN MODIFICATIONS, AS WELL AS ANY COSTS ASSOCIATED WITH SUCH MODIFICATIONS, MADE WITHOUT THE WRITTENAPPROVAL OF ENGINEER/ARCHITECT OF RECORD SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 3. CONTRACTOR SHALL VERIFY ALL RELEVANT CONDITIONS AND DIMENSIONS OF EXISTING CONSTRUCTION BEFORE PROCEEDING WITH THE WORK. CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND UTILITIES. IF EXISTING STRUCTURE IS DIFFERENT FROM WHAT IS SHOWN ON PLAN, CONTACT STRUCTURAL ENGINEER BEFORE PROCEEDING WITH ANY WORK IN THAT AREA. 4. THE CONTRACTOR SHALL SAFELY SHORE EXISTING CONSTRUCTION WHEREVER EXISTING SUPPORTS ARE REMOVED TO ALLOW INSTALLATION OF NEW WORK TOP OF SLAB 3 1/2" MIN. 6 1/2" MAX 3" O OPENING FOR SANITARY LINE (2) EXISTING C10X20 BACK TO BACK EXISTING PIERS TYP. 04 OPENING IN STEEL DETAIL SCALE: 1" = 1'-0" SECTION DETAIL CONTRACTOR COPY THESE PLAIN'S AND ALL PROP0850 WORK ARE SUBJECT TO ANY COE#iEC-fiCPJS REOUIRL"D BY PICLD rNSPFC15DRS THAT F41AY HE NECESSARRY IP10141DM TO COMPLY WITH ALL APPLICABLE CODES. REMOVE AND REPLACE SLAB AS NEEDED, SEE DETAILS 2 AND 3 ON S-1 EXIST. W8X10 z 0 > 7007 DISCOVERY BLVD DUBLIN, OH. 43017 614.634.7000 T WDPARTNERS.COM A. Re,-"Ao i kE: W4u 1S�0NA� MAY 2 2 2015 O a m 0 c O 0 0 N C 0 U NO c: 0 i mO00 a3NO 2yc� a a1'nn o �acc =N Q Lo LL O z ® co }u- �' _ 5 Q w LD J ® cn = _ ® (D 0- STORE OR 6485 BLDG NO. VERSION OR AFE NO. SCALE: 0 4 DESIGN TEAM JDATE DGNR. J. YOUST 05-22-2015 PM./DP. D. TIMMER 05.22.2015 RVR./DP. C. REZABEK 05.22.2015 DRWG. NO. S- ° - ------ -------�---- (E)C8x1_1.5- I f I I I I I I I U c co cn I cocn I cn W I co W I W.f w l w l w I w I wl I w I Bj) I I I I I I I I I A ( I A dE) (2) Cis x 33.91 --� - - - I -- - - - -- - - - L-- I I I I I I I I I I I I x I ^k C'S cn w ca cn co cn U wl I WI wl w1 wl w1 vl I I I I I I I I I I I 1 I I I I I I I I I I I I itLJ I I I N CU-1 I I I IL--- JI I I I I I I I I I I I I (E)C4x5.4_ I I I I I I I I I I A I RTU-1 ® I I E7 I f I (E)C4 x5.4 ao r afil al I n I I ^L ^I I x I LOI LO of x I� x 6 x 05 x �t .t UC x x x x x v d' U UI x It U x VI �r UI. co C7I IU NI NI aI UI �I vl I WI vl C/3I W I W I ILL! I W w� (E) (2) C15 x 33.9 -_ co Gu I 1 I I (E)C6x8_2- F I W.I ---- (E) W8x18 IjIj I I I I 1 I I I I (E) G6x6.2 of r Ix- N-----IN 00 � n �I U al cn �I cn �I U (E) C6 x 8.2 x t� U I _-__ (�6x8.2 I-- -I x �I x vl x �I x v'I w vl w Vf ILL vl IL I ---Lul I I w VI w vl w vl w vl k (E)G6.X 6..2 I I I I-- I --I82 TE)Cfix - (E)C6x8.2 I I I I I I (E)CIS x8_2 I--------- - - - - - - -- (E)C8x11.5 ----------I(E)W8x18 -- O j 3x2x3/1 -- --- (E)C8x11.5 (E)CIS x8.2--- SCALE: 1/4" = 1'-0" co U I Lu w I I rJ THESE PLMS AND ALL PROPOS50 WORK, ARE SUBJECT TO ANY CORdiECTICNS REQUIRED BY FIELD NSPEC PORS THAT r4AY BE NECINA'RY IN OnDn TO COMPLY WITH ALL APPLICACLE CODES, PLAN NOTES: 1- REFER TO SHEET S-2 FOR GENERAL STRUCTURAL NOTES. 2. ANY CHANGES MADE TO THE DESIGN IDENTIFIED ON THESE DRAWINGS AND/OR ASSOCIATED SPECIFICATIONS SHALL BE SUBMITTED TO THE ENGINEER/ ARCHITECT OF RECORD FOR REVIEW AND APPROVAL PRIOR TO MAKING ANY MODIFICATIONS TO THE PROJECT. ANY LIABILITY AS A RESULT OF DESIGN MODIFICATIONS, AS WELL AS ANY COSTS ASSOCIATED WITH SUCH MODIFICATIONS, MADE WITHOUT THE WRITTEN APPROVAL OF ENGINEER/ARCHITECT OF RECORD SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 3. CONTRACTOR SHALL VERIFY ALL RELEVANT CONDITIONS AND DIMENSIONS OF EXISTING CONSTRUCTION BEFORE PROCEEDING WITH THE WORK. CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND UTILITIES. IF EXISTING STRUCTURE IS DIFFERENT FROM WHAT IS SHOWN ON PLAN, CONTACT STRUCTURAL ENGINEER BEFORE PROCEEDING WITH ANY WORK IN THAT AREA. 4. THE CONTRACTOR SHALL SAFELY SHORE EXISTING CONSTRUCTION WHEREVER EXISTING SUPPORTS ARE REMOVED TO ALLOW INSTALLATION OF NEW WORK 5. EXISTING (E) EQUIPMENT FOR REFERENCE. NO STRUCTURAL SCOPE. ROOF FRAMING PLAN KEYED NOTES: (A NEW ROOFTOP MECHANICAL UNIT. REFER TO DETAILS ON S-3. 0 SUSPENDED EXHAUST HOOD. SEE 87 FOR SUPPORT' DETAILS. STRUCTURAL GENERAL NOTES:. A.GENERAL 1. ANY CHANGES MADE TO THE DESIGN IDENTIFIED ON THESE DRAWINGS AND/OR ASSOCIATED SPECIFICATIONS SHALL BE SUBMITTED TO THE ENGINEER/ARCHITECT OF RECORD FOR REVIEW AND APPROVAL PRIOR TO MAKING ANY MODIFICATIONS TO THE PROJECT. ANY LIABILITY AS A RESULT OF DESIGN MODIFICATIONS, AS WELL AS ANY COSTS ASSOCIATED WITH SUCH MODIFICATIONS, MADE WITHOUT THE WRITTEN APPROVAL OF ENGINEER/ARCHITECT OF RECORD, SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 2. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS WHICH MIGHT BE NECESSARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER THE COMPLETION OF THE PROJECT. 3. IT'S SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. 4. EQUIPMENT FRAMING LOADS, OPENINGS AND STRUCTURE IN ANY WAY RELATED TO HVAC, PLUMBING OR ELECTRICAL REQUIREMENTS ARE SHOWN FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL OBTAIN APPROVAL OF THE INVOLVED TRADES BEFORE PROCEEDING WITH SUCH PORTION OF THE WORK. EXCESS COST RELATED TO VARIATION IN THESE REQUIREMENTS TO BE BORNE BY THE APPROPRIATE CONTRACTOR. 5. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE PLANS CONFLICT WITH THESE STRUCTURAL NOTES, THE SPECIFICATIONS OR WITH EACH OTHER, THE STRICTEST PROVISION SHALL GOVERN. 6, ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE VERIFIED BY THE CONTRACTOR AND SHALL CONFORM TO THOSE SHOWN ON THE ARCHITECTURAL DRAWINGS. 7. PROVIDE TEMPORARY SUPPORTS AND OTHER MEASURES AS REQUIRED TO PREVENT DAMAGE TO THE EXISTING BUILDING DURING CONSTRUCTION. FIELD VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS WHICH AFFECT THE NEW CONSTRUCTION. 8. WHERE EXISTING FIREPROOFING IS TO BE DISTURBED TO ALLOW INSTALLATION OF NEW BRACING OR SIMILAR CONSTRUCTION, CONTRACTOR SHALL REPLACE IN KIND AFTER ALL NEW CONSTRUCTION IS IN PLACE. ALL STEEL STRUCTURES MUST BE COVERED BY ADEQUATE F.R. MATERIAL OR MAINTAIN WITH SAME F.R. MATERIAL. 9. CONTRACTOR SHALL SUBMIT TO THE ENGINEER, FOR REVIEW, SPECIFICATIONS FOR ANY ITEMS INTENDED TO BE USED AS A SUBSTITUTIONS FOR ITEMS SPECIFIED IN THESE DRAWINGS. CONTRACTOR SHALL NOT PROCEED UNTIL THE SUBSTITUTION HAS BEEN REVIEWED AND APPROVED BY THE ENGINEER. B. GOVERNING CODE INFORMATION 1. CONTROLLING BUILDING CODE: 2010 FLORIDA BUILDING CODE WITH 2012 AMENDMENTS A. DEAD LOADS 1) DESIGN ROOF DEAD LOAD = 20 PSF (10 PSF FOR UPLIFT CALCULATIONS) B. LIVE LOADS 1) DESIGN ROOF LIVE LOAD = 20 PSF C. SNOW LOADS (N/A) D. WIND LOADS (RISK CATEGORY II) 1) ULTIMATE WIND SPEED, Vult = 158 MPH (EXPOSURE C) E. SEISMIC DESIGN PARAMETERS (N/A) C. EXISTING CONSTRUCTION 1. EXISTING CONSTRUCTION SHOWN ON THE STRUCTURAL DRAWINGS WAS OBTAINED FROM EXISTING DRAWINGS SUPPLIED BY OWNER. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT/ENGINEER OF ANY EXCEPTIONS BEFORE PROCEEDING WITH THE WORK. 2. THE REMOVAL, CUTTING, DRILLING, ETC. OF EXISTING WORK SHALL BE PERFORMED WITH GREAT CARE AND SMALL TOOLS IN ORDER NOT TO JEOPARDIZE THE STRUCTURAL INTEGRITY OF THE BUILDING. IF STRUCTURAL MEMBERS, NOT INDICATED FOR REMOVAL, INTERFERE WITH THE NEW WORK, THE STRUCTURAL ENGINEER SHALL BE NOTIFIED IMMEDIATELY, AND PRIOR APPROVAL OBTAINED, BEFORE REMOVAL OF THE MEMBER. 3. THE CONTRACTOR SHALL SAFELY SHORE EXISTING CONSTRUCTION WHEREVER EXISTING SUPPORTS ARE REMOVED TO ALLOW INSTALLATION OF THE NEW WORK. THE EXISTING CONSTRUCTION SHALL BE CONNECTED AND/OR EMBEDDED INTO THE NEW CONSTRUCTION AS SHOWN OR SPECIFIED. D. STRUCTURAL STEEL 1. MATERIALS: A. STRUCTURAL STEEL: WIDE FLANGE BEAMS: ASTM A992, Fy=50 KSI CHANNELS & ANGLES: ASTM A36, Fy=36 KSI STRUCTURAL PIPES: ASTM A53 OR A501, Fy=35 KSI MIN. SQUARE & RECTANGULAR TUBING: ASTM A500, Fy=46 KSI HIGH STRENGTH BOLTS` ASTM A325 OR A490 ANCHOR RODS: ASTM F1554 GRADE 36 RODS: ASTM A36 EXPANSION ANCHORS: HILTI "KWIK BOLT-TZ" ([CC ESR-1917) WELDING ELECTRODES: E70XX 2. SPECIFICATIONS: WELDING PERSONNEL AND PROCEDURES ARE TO BE CERTIFIED PER AWS D1.1, UNLESS SPECIFICALLY SHOWN OTHERWISE. 3. DESIGN, FABRICATION AND ERECTION TO BE GOVERNED BY THE LATEST EDITION OF: A. AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS. B. AISC CODE OF STANDARD PRACTICE. C. STRUCTURAL WELDING CODE, AWS D1.1 OF THE AMERICAN WELDING SOCIETY. D. SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. 4. CONNECTIONS: A. SHOP CONNECTIONS CAN BE BOLTED OR WELDED. FIELD CONNECTIONS CAN BE FIELD WELDED PER DETAILS. B. FOLLOW INSTRUCTIONS ON DRAWINGS FOR GENERAL ARRANGEMENT OR PARTICULAR DETAILS. FIELD CONNECTIONS NOT OTHERWISE NOTED TO BE BOLTED. 5. MISCELLANEOUS: A. EMBEDMENT LENGTH OF EXPANSION BOLTS INTO SOLID MASONRY OR CONCRETE SHALL BE AS FOLLOWS: 1/2" DIAMETER BOLTS - 2 1/4" EMBEDMENT U.N.O. 518" DIAMETER BOLTS - 23/4" EMBEDMENT U.N.O. 6. GALVANIZING: ALL SHELF ANGLES, LINTELS IN EXTERIOR WALLS, AND ALL EXTERIOR STEEL EXPOSED TO THE ELEMENTS SHALL BE HOT -DIPPED GALVANIZED AFTER FABRICATION. 7. STEEL SUPPORTING OR CONNECTED TO HVAG AND OTHER EQUIPMENT AND ROOF OPENINGS AS SHOWN ON THE DRAWINGS IS SHOWN FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL RECONCILE EXACT SIZE AND LOCATION BEFORE PROCEEDING WITH THE WORK. 8. PROVIDE SPECIAL INSPECTIONS TO MEET REQUIREMENTS OF CHAPTER 17 OF THE GOVERNING BUILDING CODE. E. CAST -IN -PLACE CONCRETE 1. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS, WITH A WATER CEMENT RATIO = .50 (MAXIMUM). CONCRETE EXPOSED TO WEATHER SHALL BE AIR -ENTRAINED AT6% t 1.5%. SUBMIT CONCRETE MIXES FOR REVIEW BEFORE PLACING CONCRETE IN ACCORDANCE TO ACI 301. 2. ALL REINFORCING' STEEL SHALL BE NEW DOMESTIC DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 GRADE 60. 3. WELDED WIRE REINFORCEMENT SHALL CONFORM TO ASTM A-185 DELIVERED IN FLAT SHEETS. 4. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH "SPECIFICATION FOR STRUCTURAL CONCRETE" ACI 301, AND "GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION" ACI 302. 5. ALL REINFORCING DETAILS SHALL CONFORM TO "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES' ACI 315, UNLESS DETAILED OTHERWISE ON THE STRUCTURAL DRAWINGS. 6. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL OPENINGS, SLEEVES, ANCHOR RODS, INSERTS, ETC., AS REQUIRED BY OTHER TRADES BEFORE CONCRETE IS PLACED. 7. CONTRACTOR SHALL PROVIDE SPACERS, CHAIRS, BOLSTERS, ETC., NECESSARY TO SUPPORT REINFORCING STEEL. CHAIRS WHICH BEAR ON EXPOSED CONCRETE SURFACES SHALL HAVE ENDS WHICH ARE PLASTIC TIPPED OR STAINLESS STEEL. B. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT: 3" CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH. 2" CONCRETE EXPOSED TO EARTH OR WEATHER, #6 THRU #18 BARS. 1-1/2" CONCRETE EXPOSED TO EARTH OR WEATHER, #5 BAR & SMALLER. 1-1/2" CONCRETE NOT EXPOSED TO WEATHER NOR IN CONTACT WITH EARTH FOR THE PRIMARY REINFORCEMENT, TIES, STIRRUPS AND SPIRALS IN BEAMS AND COLUMNS. 3/4" CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH EARTH FOR SLABS, WALLS AND JOISTS, #11 BAR & SMALLER. CONTIRACTiR COPY SPECIAL INSPECTIONS REQUIRED PER THE IBC 1. THE OWNER WILL EMPLOY THE SERVICES OF ONE OR MORE SPECIAL INSPECTORS TO PROVIDE SPECIAL INSPECTIONS DURING CONSTRUCTION 2. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL AND THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. 3. DUTIES AND RESPONSIBILITIES OF THE SPECIAL INSPECTOR: A. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. THE INSPECTOR MAY NOT ALTER, MODIFY, ENLARGE OR WAIVE ANY OF THE REQUIREMENTS OF THE DOCUMENTS. B. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, THE PROFESSIONAL OF RECORD, AND THE CONTRACTOR. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, SUBMIT A COMPLETE LIST OF ALL OUTSTANDING DISCREPANCIES ON A WEEKLY BASIS TO THE OWNER, THE BUILDING OFFICIAL, AND THE PROFESSIONAL OF RECORD UNTIL ALL CORRECTIONS HAVE BEEN COMPLETED. C. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION' WAS, TO THE BEST OF THE INSPECTOR'S KNOWLEDGE, IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE. 4. WHERE SPECIAL INSPECTION REQUIREMENTS DUPLICATE THE REQUIREMENTS OF SPECIFIED QUALITY ASSURANCE TESTING, DUPLICATE INSPECTIONS SHALL NOT BE REQUIRED. 5. PROVIDE CONTINUOUS SPECIAL INSPECTIONS FOR ALL STEEL CONSTRUCTION AS REQUIRED PER IBC SECTION 1705.2, 1705.11.6, AND AISC 360-10. 6. PROVIDE CONTINUOUS SPECIAL INSPECTIONS FOR ALL POST -INSTALLED ANCHORS INTO CONCRETE/MASONRY PER MANUFACTURER INSTRUCTIONS PER IBC SECTION 1705.3 AND TABLE 1705.3. 0 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM .•`��rc. A. R �•4!•i• ..... _"49•i• r� 8 T 0 tub: �cFS.4ORNOP ♦♦`` NAL ♦�`� 0 z 0 w rr MAY 2 2 2015 a 0 C 0 +r U 0 c U bll T � m�`y= 20❑� ono �¢al aNCL wW LL = N °co co -J J LL f LL of (D Q LU cc Gcn J) :D :D c) d BLDGNO. 6485 VERSION OR AFE NO. SCALE: 0 4 DESIGN TEAM I DATE DGNR. J. YOUST 05-22.2015 PM./DP. D. TIMMER 05-22.2015 RVR./DP. C. REZABEK 05-22.2015 DRWG. NO. ry/ S2 1 1/2" METAL DECK CONDENSER STAND. C6x8.2 STEEL REFER TO SECTION CHANNEL (FLAT) BELOW WELD THROUGH DECK, TYP. 3/16 3 — VARIES T.O. JOIST REFER TO PLAN FOR STEEL SHAPE AND SIZE. c TYPICAL STAND HOLD-DOWN V J SCALE: NONE SECTION DETAIL TIE -DOWN STRI ROUND TUBING & BASE PLATE WATER SEALANT - SEE ARCH ITECTURAL—�. DWGS FOR ROOF MATERIAL WATERPROOF MEMBRANE ROOFDECK STEEL ANGLE - L5" x 3"—'� U-BOLT W/ NUTS & WASHER 1 1;4-20 X 1/2" THRUBOLTS TO INTERLOCK SQUARE TUBING A/C UNIT ISOLATOR PADS BEYOND 1/4" FILLET WELD FULL POST CIRCUMFERENCE TO BASE PLATE CHANNEL 1/4-20 X 112" GALVANIZED BOLT; FULLY TIGHTEN TO REFUSAL PROVIDE FILLET WELD FOR FULL VISIBLE CIRCUMFERENCE OF'C' CHANNEL TO ROUND TUBING ROOFING FLASHING FILLED WITH TAR SEALING �-1 "X 22ga CONTINUOUS GALV STEEL STRAP SHALL PASS OVER UNIT TO I -BEAM ON OPPOSITE SIDE, MIN (2) PER UNIT (2) #14 SMS AT EACH; STRAP END TO UNDERSIDE OF I -BEAM —1.9" ROUND TUBING U-BOLT W/ NUT & WASHER TO STRUCTURAL STEEL MEMBERS, SIZE AS NEEDED TO SECURE CURB —4"X4" BASE PLATE CURB CON IGURATIONS: MAINTAIN ALL LEG SPACING/UNIT CONFIGURATIONS AS SHOWN. DISTRIBUTE WEIGHT EVENLY. VERIFY ALL DESIGNS AND ACTUAL LOCATION OF CURB WITH STRUCTURAL ENGINEER. CENTER LEG LOCATIONS TO BE DESIGNED SO THAT BASE PLATE CAN BE SECURELY ATTACHED TO ROOF DECK. SINGLE UNIT DOUBLE UNIT 700 LBS 350 LBS 350 L13S MAX MAX MAX WEIGHT WEIGHT WEIGHT TRIPLE UNIT 350 LBS 350 LBS 350 LBS MAX MAX MAX WEIGHT WEIGHT WEIGHT Y J1 EO EO 6'-0' MAX I- 6'-0" MAX I 9'-0" MAX 1 NO1 ES: 1 • CONDENSING UNIT RACK TO BE HEAVY DUTY ALUMINUM RACK BY: PRECISION ALUMINUM PRODUCTS (954) 480-6919 ACSTANDS.COM • CURB RAIL, FLASHING, AND ALL FASTENERS TO BE PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. • CONDENSING UNIT PROVIDED BY TI IE PANTRY ROOF CONDENSER CURB DETAIL ®4 SCALE: NONE ISOMETRIC SPLAY WIRE ATTACH TO FRAMING WITH CEILING CLIP EXISTING STEEL CHANNEL AND ROOF DECK. 5/16"x1 3/4"xt 3/4" SQUARE WASHER TOP & BOTTOM - TIGHT AGAINST BACK OF CHANNEL 5/16"xi 3/4"x1 3/4" SQUARE WASHER TOP DETAIL A & BOTTOM, TYP. (*) (2) 12GA. WIRES SPLAYED 90 DEGREES FROM EACH OTHER AND MAX. 45 DEGREES FROM CEILING PLANE, TYP. EACH CORNER (8 TOTAL), FASTEN TO FRAMING PER DETAIL "A" HOOD PER MECHANICAL DRAWINGS —� 5/16"x1 3/4"x1 3/4" SQUARE WASHER TOP & BOTTOM - TIGHT AGAINST BACK OF CHANNEL. - UNISTRUT P5000HS, TYP SPLAY WIRE ATTACH TO FRAMING WITH DETAIL A L3x3x1/4 FRAME EXISTING TYP, AROUND METAL ROOF OPENING IN METAL DECK DECK, ANGLE TO CHANNEL, 3/16 TYP. EXISTING STRUCTURAL MEMBER DETAIL C L3x3x1/4 FRAME TYP. AROUND OPENING IN METAL DECK. 6" MAX. 10 5/16"x1 3/4"xt 3/4" SQUARE WASHER TOP & BOTTOM - TIGHT AGAINST BACK OF CHANNEL. - P5000 HS UNISTRUT CONT. ACROSS MIN. 2 STEEL CHANNELS AT HOOD SUPPORT ROD LOCATIONS ALL -THREADED HANGER ROD PER MECH. EQUIP. REQUIREMENTS (100 LBS MAX. PER ROD). (2) HEX NUTS AT WIRE CONNECTION, MECHANICALLY TIGHTEN AFTER SPLAY WIRES HAVE BEEN TIED. — UNISTRUT P2786 BEAM CLAMP, TYP. 01 SUSPENDED HOOD AND BRACING DETAILS SCALE: NONE SECTION DETAIL 5/16"x1 3/4"xt 3/4" SQUARE WASHER TOP & BOTTOM - TIGHT AGAINST BACK OF CHANNEL. SELF-LOCKING NUT UNISTRUT P2786 BEAM CLAMP, (TYP. OPTION "A" OR "B") F TYP. 5/16"x1 3/4"xt 3/4" SQUARE WASHER BOTTOM, TYP. \� NEW HVAC UNIT - SEE MECHANICAL SHEETS 1/2" ALL THREAD +� SUSPENDED MECHANICAL L SCALE: 4" = 1'-O" PLAN DET THESE PLANS AND ALL PROPOSED N. okK ARE SUBJECT TO ANY CORRECTIONS REQUIReD BY FIELD MISPECIORS THAT MAY BE NECP%Aly IN QRDM TO COMPLY WITH ALL APPLICABLE COL F& EXISTING METAL ROOF DECK ANGLE TO CHANNEL, 3/16 TYP. EXISTING CHANNEL DETAIL B 3/16 OPENING IN METAL DECK AS — REQUIRED. _ V.I.F. 3/0 TRUSS COORDINATE ROD LENGTH & QUANTITY WITH EQUIPMENT SPECIFICATIONS (2) 12GA. WIRES SPLAYED 90 DEGREES FROM EACH OTHER AND MAX. 45 DEGREES FROM CEILING PLANE, TYP. EACH CORNER (8 TOTAL), FASTEN TO FRAMING PER DETAIL "A" IPMENT DETAIL CONT14CTOR COPY Mrs 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM A. gE2q '�i i 3F • 9�� �� UO� Z z z 0 W w A'4ORID S/ONAL, 4i a k� N n c O u H1 c O co 04 Oo bA 3:0 0 0 >A:2 dya vac= �dtAWW w ¢ �o — L3x3x1/4 FRAME TYP. AROUND OPENING IN METAL DECK. W L5x3 1/2x3/8x0'-10" LLV, TYP. COPE J HORIZONTAL LEG TO FIT BETWEEN DECK RIBS. = N ~ M �. i OU m - 4B J } LL � B Typ' INDICATES SPAN DIRECTION OF EXTG. METAL ROOF DECK. EXTG. ROOF STEEL J ¢w < 3 U � J U) U) U �F_ Of CD U) NOTE: COORDINATE SIZE AND LOCATION OF �i OPENINGS WITH MECHANICAL SUPPLIER AND ARCHITECTURAL REQUIREMENTS. STORE OR 6485 BLDG NO. VERSION OR APE NO. L5 3 5/16 LLV TYP AT EQUIP CURB SCALE: I SEE PLAN x x AS NOTED ROOF MOUNTED MECH SUPPORT DESIGN TEAM DATE 03 SCALE:4" = 1'—O" DGNR. J. YOUST 05-22-2015 PLAN DET_ ,PM./DP. D. TIMMER 05-22-2015 RVR./DP. C. REZABEK 05.22-2015 DRWG. NO. S-3 FLOOR DEMOLITION PLAN NOTES: 1. EQUIPMENT / FURNITURE TO REMAIN. COORDINATE ANY REPAIRS WITH PROJECT MANAGER. 2. NOT USED 3. EQUIPMENT / FURNITURE TO BE REMOVED. COORDINATE WORK WITH PROJECT MANAGER. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF EQUIPMENT UNLESS OTHERWISE INSTRUCTED BY PROJECT MANAGER. REMOVE ALL PLUMBING AND ELECTRICAL ASSOCIATED WITH EQUIPMENT BACK TO SOURCE UNLESS OTHERWISE NOTED ON PLUMBING AND ELECTRICAL DRAWINGS. 4. WALL(S) / PARTITION(S) TO REMAIN. REFER TO FLOOR PLAN FOR EXTENT OF NEW WORK REQUIRED ON EXISTING WALL. FINISH MATERIALS TO REMAIN UNLESS OTHERWISE NOTED. REFER TO FINISH PLAN. 5. PROJECT MANAGER AND CONTRACTOR SHALL COORDINATE WITH MARKETING DEPARTMENT FIELD MERCHANDISER FOR REMOVAL OF EXISTING GONDOLA EQUIPMENT. 6. REMOVE MERCHANDISING AND STORAGE RACKS, AND/OR SHELVING. COORDINATE WITH PROJECT MANAGER FOR REUSE OF SHELVING AND STORAGE OF MERCHANDISE. GONDOLA SHELVING RELOCATION MAY ALREADY BE COMPLETED BY OTHERS BEFORE REMODEL. VERIFY AT BID WALK. 7. NOT USED 8. NOT USED 9. EXISTING EQUIPMENT AND FURNITURE TO REMAIN AS IS. 10. REMOVE WALL FINISHES, GRAPHICS, AND APPLICATIONS TO ALLOW FOR INSTALLATION OF NEW CABINETRY AND/OR MERCHANDISING EQUIPMENT. INSTALL STRAIGHT AND PLUMB. REFER TO FINISH PLAN. COORDINATE WITH PROJECT MANAGER. 11. REMOVE WALL / PARTITION. REMOVE ACCESSIBLE GAS, PLUMBING, ELECTRICAL, AND TELEPHONE FEEDERS PER ELECTRICAL DEMOLITION PLAN. CAP ALL INACCESSIBLE UTILITIES PER APPLICABLE CODES AND INDUSTRY STANDARDS. 12. REMOVE COOLER PANELS AND COOLER DOORS AS NEEDED FOR NEW COOLER LAYOUT. 13. NOT USED 14. NOT USED 15. NOT USED 16. NOT USED 17, EXISTING FLOOR TILE TO REMAIN. 18. EXISTING SIDEWALK TO REMAIN. 19. NOT USED 20. COORDINATE SAWCUTS OF CONCRETE WITH PLUMBING AND ELECTRICAL DRAWINGS. 21. NOT USED 22. REFER TO MPE DRAWINGS FOR EXTENT OF MECHANICAL, PLUMBING, AND ELECTRICAL DEMOLITION. 23. EXISTING PLUMBING FIXTURES TO REMAIN. 24. NOT USED 25. NOT USED 26. NOT USED 27. NOT USED 28. EXISTING CAMERAS AND SPEAKERS TO REMAIN. 29. NOT USED 30. EXISTING ELECTRICAL EQUIPMENT TO REMAIN. 31. NOT USED 32. REMOVE EXISTING COOLER DOORS AND 5-DOOR FRAME. STORE THE FOUR BEST COOLER DOORS FOR REUSE. 33. NOT USED 34. NOT USED 35. NO DEMOLITION IN THIS AREA. 36. EXISTING CANOPY TO REMAIN. 37. EXISTING COOLER/FREEZER EVAPORATORS TO REMAIN. 38. REMOVE METAL COLUMN COVERS AND ACCESSORIES. 39. NOT USED 40, NOT USED FLOOR DEMOLITION LEGEND O SEE DEMOLITION PLAN NOTES - EXISTING WALLS, EQUIPMENT, - FURNITURE, & ETC. TO BE REMOVED EXISTING WALLS, EQUIPMENT, F - APPROXIMATE LOCATION OF FURNITURE, & ETC. TO REMAIN _7 CONCRETE SLAB SAW CUTS 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000T WDPARTNERS.COM P� R K F` �O 9 MAY 2 2 2015 .1i a d) c O 0 U 7 a c 0 U GN t9 M nay a�N® a IV Uo V1tW a FLOOR DEMOLITION GENERAL NOTES: z O A. THESE DRAWINGS DO NOT INDICATE THE FULL EXTENT OF THE WORK DETAILS REQUIRED TO COMPLETE THIS REMODEL w PROJECT. VERIFY EXISTING CONDITIONS FOR THE FULL EXTENT OF THE WORK REQUIRED TO COMPLETE THIS PROJECT IN A WORKMANLIKE MANNER PER ALL APPLICABLE CODES AND THESE DRAWINGS. COORDINATE WORK WITH THE PROJECT MANAGER. B. DEMOLISH EXISTING CONSTRUCTION ONLY TO THE EXTENT NECESSARY TO COMPLETE THE NEW CONSTRUCTION. CUT BACK EXISTING FINISHED SURFACES TO SQUARE, LEVEL, AND PLUMB LINES. C. CAREFULLY REVIEW PLANS AND DETERMINE UTILITIES THAT ARE REQUIRED TO BE DISCONNECTED AND THOSE THAT WILL REMAIN FUNCTIONAL. COORDINATE WORK WITH THE APPROPRIATE UTILITY PROVIDER. SCHEDULE WORK FOR A MINIMUM OF INTERRUPTION. 0 D. REMOVE AND SECURE ALL GAS, PLUMBING, ELECTRICAL, AND OTHER UTILITIES ASSOCIATED WITH EQUIPMENT REMOVED FROM SITE. INSTALL REQUIRED MATERIALS TO SECURE AND MAKE SAFE ALL UTILITIES TO REMAIN. E. PREVENT PUBLIC ACCESS TO THE WORK AREA. INSTALL BARRIERS AND SIGNAGE TO ALERT THE GENERAL PUBLIC, EMPLOYEES, AND CONTRACTORS OF DANGERS. F. GENERAL CONTRACTOR SHALL PROTECT ALL EQUIPMENT THAT WILL REMAIN FOLLOWING REMODEL BY PLACING IT IN STORAGE z cu FOR THE DURATION OF THE PROJECT. COORDINATE WITH THE PROJECT MANAGER. O Lo rn G. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING WORK PERMITS AND COMMUNICATING WITH UTILITY PROVIDER(S) PRIOR a) TO ANY WORK AFFECTING SERVICES. FIELD VERIFY LOCATION OF ALL SERVICES. �- O co H. CONTRACTOR SHALL VERIFY w/ PROJECT MANAGER ALL EQUIPMENT & FURNITURE TO BE REMOVED AND RELOCATED PRIOR TO J J O = I. ANY WALLS BE IN PROP SED FOR REMOVAL SHALL BE CONFIRMED BY THE CONTRACTOR AS BEING NON -LOAD BEARING Q LU FLOOR DEMOLITION PLAN BEFORE PROCEEDING WITH REMOVAL, IF LOAD -BEARING WALLS)F ARE FOUND DUE TO UNFORESEEN CONDITIONS, IT SHOULD BE w J � J SCALE: 1 /4" = 1 �-O" BROUGHT DIRECTLY TO THE PROJECT MANAGER'S ATTENTION BEFORE PROCEEDING WITH THE REMOVAL OF THAT WALL. NOTE: THE ARCHITECT HAS MADE ASSUMPTIONS BASED ON PREVIOUS DRAWINGS AND THE EXISTING CONDITIONS THAT ARE VIEWABLE. ® 0- I HE HAS USED HIS BEST JUDGMENT TO DETERMINE ALL LOAD -BEARING WALLS. �/ a ® �CE ® � EL LL THEE PLAINS AND ALL PROPOSSD W011K ARE SUBJECT TO ANY CORAECTICNS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECINA2Y IN ORDER TO COMPLY WITH ALL APPLICABLE CODES, CONTRACTOR COPY STORE BLDG NO. 6485 VERSION OR AFE NO. SCALE: ❑a w3 wo w mw a N FOw zz IN y zz0 ¢o �z ¢w ok w� wo ow ))'N F2 ¢a aw 0� wi ND zw U 30 �o oa yw 0 I DESIGN TEAM I DATE II DGNR. J. YOUST 106-22.20151 PM./DP. D. TIMMER 105-22.20151 RVR./DP. B. BUZARD05-22.2015 DRWG. NO. D-1 I MEN HALL UTILITY 1 7 14 TYP SALES AREA UNO TYP SALES AREA UNO CEILING DEMOLITION PLAN SCALE: 1/4" = 1'-0" CEILING DEMOLITION PLAN NOTES: 1. EXISTING CEILING GRID AND TILE TO REMAIN. REPLACE ANY DAMAGED OR DIRTY TILES WITH NEW TO MATCH EXISTING. md 2. EXISTING CEILING GRID TO REMAIN, REMOVE EXISTING TILE. REFER TO SHEET A2 FOR EXTENTS OF NEW TILE. 3. NOT USED 4. NOT USED 5. NOT USED 6. NOT USED 7007 DISCOVERY BLVD DUBLIN, OH 43017 7. EXISTING DIFFUSERS AND RETURN GRILLES TO REMAIN. 614.634.7000T 8. NOT USED 9. EXISTING CEILING MOUNTED EXHAUST FAN TO REMAIN. WDPARTNERS.COM 10. NOT USED 11. NOT USED 12. NOT USED �j QrER FC. O 9jO 13. IF NECESSARY, REMOVE AND RELOCATE MOTION SENSORS, DOOR CONTACTS, CAMERAS AND SECURITY SYSTEM EQUIPMENT. VERIFY WITH PROJECT • _ _ �N'. MANAGER. REFER TO SECURITY PLAN FOR NEW AND RELOCATED CAMERAS AND ASSOCIATED WIRING- n 14. EXISTING LIGHT FIXTURE TO REMAIN. • 15. REMOVE EXISTING LIGHT FIXTURE AND PULL WIRE AND CONDUIT BACK TO NEXT REMAINING DEVICE. MAINTAIN POWER CONNECTION TO REMAINING DEVICES IN CIRCUIT. REFER TO ELECTRICAL DRAWINGS FOR NEW WORK OR REUSE OF SALVAGED FIXTURES. C) 16. EXISTING EXIT /EMERGENCY UNIT TO 17. REMOVE EXIT LIGHT/EMERGENCY TREMAIN. UNIT AND PULL WIRE AND CONDUIT BACK TO NEXT REMAINING DEVICE. MAINTAIN POWER CONNECTION TO REMAINING RFD ARG�\�� DEVICES IN CIRCUIT. REFER TO ELECTRICAL DRAWINGS FOR NEW WORK OR REUSE OF SALVAGED FIXTURES. 18. EXISTING CEILING RECEPTACLES TO REMAIN. 19. NOT USED MAY 2 2 2015 20. NOT USED 21. EXISTING BULKHEAD TO REMAIN. 22. REMOVE AND RELOCATE EXISTING EVAPORATOR. SEE MECHANICAL DRAWINGS. 23. NOT USED 24. EXISTING SOFFIT TO REMAIN. S N 0 0 CEILING DEMOLITION GENERAL NOTES: A. THESE DRAWINGS DO NOT INDICATE THE FULL EXTENT OF THE WORK DETAILS REQUIRED TO COMPLETE THIS REMODEL PROJECT. VERIFY EXISTING a CONDITIONS FOR THE FULL EXTENT OF THE WORK REQUIRED TO COMPLETE THIS PROJECT IN A WORKMANLIKE MANNER PER ALL APPLICABLE CODES AND THESE DRAWINGS. COORDINATE WORK WITH THE PROJECT MANAGER. U B. DEMOLISH EXISTING CONSTRUCTION ONLY TO THE EXTENT NECESSARY TO COMPLETE THE NEW CONSTRUCTION. CUT BACK EXISTING FINISHED SURFACES TO SQUARE, LEVEL, AND PLUMB LINES. m cr) C. CAREFULLY REVIEW PLANS AND DETERMINE UTILITIES THAT ARE REQUIRED TO BE DISCONNECTED AND THOSE THAT WILL REMAIN FUNCTIONAL. r COORDINATE WORK WITH THE APPROPRIATE UTILITY PROVIDER. SCHEDULE WORK FOR A MINIMUM OF INTERRUPTION. T cu2 D. REMOVE AND SECURE ALL GAS, PLUMBING, ELECTRICAL, AND OTHER UTILITIES ASSOCIATED WITH EQUIPMENT REMOVED FROM SITE. INSTALL REQUIRED 0a -0 y O MATERIALS TO SECURE AND MAKE SAFE ALL UTILITIES TO REMAIN. m o c 1= E. PREVENT PUBLIC ACCESS TO THE WORK AREA. INSTALL 6'-0" HEIGHT FENCE AND SIGNAGE TO ALERT THE GENERAL PUBLIC, EMPLOYEES, AND v Q. c C CONTRACTORS OF DANGERS, a en w w F. GENERAL CONTRACTOR SHALL FROTECT ALL EQUIPMENT THAT WILL REMAIN FOLLOWING REMODEL BY PLACING IT IN STORAGE FOR THE DURATION OF THE PROJECT. COORDINATE WITH THE PROJECT MANAGER. G- NOT USED. H. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING WORK PERMITS AND COMMUNICATING, WITH UTILITY PROVIDER(S) PRIOR TO ANY WORK AFFECTING SERVICES. FIELD VERIFY LOCATION OF ALL SERVICES. I. CONTRACTOR SHALL VERIFY w/ PROJECT MANAGER ALL EQUIPMENT & FURNITURE TO BE REMOVED AND RELOCATED PRIOR TO COMMENCING WITH THE WORK. J. ANY WALLS BEING PROPOSED FOR REMOVAL SHALL BE CONFIRMED BY THE CONTRACTOR AS BEING NON -LOAD BEARING BEFORE PROCEEDING WITH REMOVAL. IF LOAD -BEARING WALL(S) ARE FOUND DUE TO UNFORESEEN CONDITIONS, IT SHOULD BE BROUGHT DIRECTLY TO THE PROJECT MANAGER'S ATTENTION BEFORE PROCEEDING WITH THE REMOVAL OF THAT WALL. NOTE: THE ARCHITECT HAS MADE ASSUMPTIONS BASED ON PREVIOUS DRAWINGSQ AND THE EXISTING CONDITIONS THAT ARE VIEWABLE. HE HAS USED HIS BEST JUDGMENT TO DETERMINE ALL LOAD -BEARING, WALLS. m > gk w¢ 'oo �o ii w w ma w O'N �� r0 no ZZ NN ZO aU Qw w3 y0 0, >>w FS ¢a w aw o °�5 CONTRACTOR COPY wy aw w zo mm oa yw 0 z O = N H Lo F-0-4 1 CEILING DEMOLITION PLAN LEGEND: z a w EXISTING 1 X 4 TROFFER 0 EXISTING DOWNLIGHT W Q � U © EXISTING CEILING -MOUNTED CAMERA " Q J 2 -1 0J �� EXISTING STRIP LIGHT 2 1- o EXISTING CEILING -MOUNTED SPEAKER V � EXISTING 2 X 4 TROFFER z Z H EXISTING GASKETED LIGHT FIXTURE ® EXISTING THERMOSTAT00 J r L1J ( a P EXISTING 2 X 2TROFFER, CLOSED g EXISTING WALL -MOUNTED LIGHT ���I ❑ CEILING TILE AND PADS PRISMATIC DIFFUSER i i U TO BE REMOVED AND REPLACED EXISTING 2 X 2 TROFFER, OPEN EXISTING EXIT LIGHT WITH EMERGENCY LIGHT CEILING TILE AND GRID STORE OR (� QF PARABOLIC DIFFUSER CI EXISTING EXIT LIGHT TO BE REMOVED BLDG NO. 6485 VERSION OR AFE NO. SCALE: 0 4 THESE P"NS AND ALL PROPOS O WORK NONE ARE SUBJECT TO ANY COMECTIONS DESIGN TEAM DATE RC©UIRED BY FIELD MSPECIOR$ THAT DGNR. J. YOUST 05-22.2015 MAY BE NECISSA'SY IN ORDLO R TO COMPLY WITH ALL APPLICABLE CODE'S, RD. TIMMER 05-22-2015 RVR./DR./DP. B. BUZARD 05-22.2015 DRWG. NO. Ury -^/7 L - - - - 01 FLOOR CONSTRUCTION PLAN SCALE: 1 /4" = 1'-0" A5 5/"GYPSUM BOARD, PAINTED BTM OF ROOF TRUSS DROP CEILING SEE CLG PLAN wAV FINIS 100 -0 SLIP TRACK SUSPENDED ACOUSTICAL DROP CEILING � DROP CEILING SEE CLG PLAN 6" METAL STUDS MAY OCCUR (SEE PLAN) 3-5/8"METAL STUDS @ 16" O.C. FHP, PLYWOOD, OR TILE MAY OCCUR (SEE FINISH PLAN) FINISH FLOOR OZINTERIOR WALL CONSTRUCTION SCALE: 1/2" = 1'-0" SECTION DETAIL ri 15 16 18 e 30" 10 15 0119 I s 03 I I I I I �I I I 9' MIN. (L 6' 8' Q SETON CO. ADA SIGN BLUE BACKGROUND o WHITE SYMBOLS o RAISED SYMBOLS MEN. ISED LETTERS � BRAILLE REQUIRED SIGNAGE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR. CONTRACTOR TO PRE -DRILL SIGNAGE AND MOUNT USING VANDAL RESISTANT SCREWS ACCESSIBILITY SIGNAGE FLOOR CONSTRUCTION PLAN NOTES: 1. NOT USED 2. NOT USED 3. PAINT INTERIOR PER CURRENT PAINT SCHEDULE SHEET A-3. 4. CONTRACTOR TO INSTALL CURRENT GRAPHIC STANDARDS. COORDINATE WITH THE PROJECT MANAGER. 5. NOT USED 6. NOT USED 7. PATCH EXISTING WALLAS NEEDED. FINISH AS PER FINISH PLAN OR MATCH EXISTING. 8. NOT USED 9. COOLER WALLS: GLUE FRP OR 1/2" GYP. BOARD TO ALL EXPOSED FACES PER FINISH PLAN. GYP. BOARD SHALL EXTEND FROM FLOOR TO ROOF DECK OR GYP. BOARD CEILING ABOVE. FRP OR GYP. BOARD SHALL EXTEND FROM COOLER CORNER TO WALL. 10. NOT USED 11, REMOVE EXISTING AND INSTALL NEW WALL FINISHES. SEE INTERIOR ELEVATIONS, FINISH PLAN, AND FINISH SCHEDULES. 12. EXISTING SOFFIT ABOVE. 13. EXISTING EQUIPMENT/FURNITURE TO REMAIN. 14. NOT USED 15. NEW EQUIPMENT/FURNITURE. SEE EQUIPMENT PLAN. 16. NEW WALK IN COOLER, SEE EQUIPMENT PLAN. 17. NOT USED 18. ALIGN NEW COOLER WALL WITH EXISTING COOLER WALL. 19. NEW CAVE WALL PANELS, MERCHANDISING DOORS, ENTRY DOOR. 20. ALL ATTENDANT SALES &BEVERAGE COUNTERS, CANDY RACKS, ROLLER GRILLE, AND CONDIMENT ISLANDS, CUP HOLDERS,. LID DISPENSERS, SLATWALL, TRENDAR SHELVES (IF REQUIRED), AND ALL SIMILAR FIXTURES SHALL BE FABRICATED BY CABINET VENDOR AND INSTALLED BY CONTRACTOR. NEW CABINETS PROVIDED BY CABINET MAKER AND INSTALLED BY CONTRACTOR. COORDINATE WITH PROJECT MANAGER. 21. INSTALL 4" VINYL COVE BASE ON ALL CABINETS TO BE SUPPLIED BY THE GENERAL CONTRACTOR. SEE FINISH PLAN &FINISH SCHEDULES. 22. STAINLESS STEEL CORNER GUARDS FOR CABINETRY TO BE FURNISHED BY CABINET VENDOR AND INSTALLED BY CONTRACTOR. 23. INSTALL MERCHANDISING RACKS AND SHELVING PER MARKETING PLANQGRAM FOR THIS BUILDING TYPE. COORDINATE LAYOUT WITH SPEEDWAY FIELD MERCHANDISER. FOR STORAGE SHELVING LAYOUT -SEE EQUIPMENT PLAN DRAWING "EQ-1". 24. IF FIRE EXTINGUISHER IS NOT EXISTING, INSTALL'4A608C' FIRE EXTINGUISHER INACCESSIBLE LOCATION WITH 36" CLEAR SPACE AROUND. EXTINGUISHER SHALL HAVE LABEL OF AN APPROVED AGENCY AND BE MOUNTED IN ACCORDANCE WITH NFPA. 25, PROVIDE AND INSTALL TACTILE EXIT SIGNS AT BUILDING EXIT DOORS IF NOT EXISTING. 26. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE PLACED BESIDE ACCESSIBLE RESTROOM DOORS IF NOT EXISTING. MOUNT 5'-0" O/C ABOVE FINISH FLOOR. SEE DETAILS ON THIS SHEET. 27. NOT USED 28, CONTRACTOR SHALL MODIFY ELECTRICAL AND PLUMBING AS REQUIRED FOR NEW EQUIPMENT LOCATIONS PER REQUIRED CODE. SEE ELECTRICAL AND PLUMBING DRAWINGS. 29. NOT USED 30. EXISTING ELECTRICAL PANELS &EQUIPMENT. SEE ELECTRICAL DRAWINGS. 31. NOT USED 32. NEW STONE / EIFS CLADDING AT COLUMNS. 33. NOT USED 34. NOT USED 35. NOT USED 36. NO WORK THIS AREA. 37, NEW COOLER ENTRY DOOR BY COOLER MFR. 38. NOT USED 39, NOT USED 40. NOT USED 41. NOT USED FLOOR PLAN GENERAL NOTES: A. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIALS AND EQUIPMENT REQUIRED FOR A COMPLETE INSTALLATION PER ALL APPLICABLE CODES AND THESE DRAWINGS, UNLESS OTHERWISE NOTED. B. ALL EXISTING FLOORS, WALLS, OR OTHER SURFACES TO RECEIVE A FINISH MATERIAL SHALL BE MADE SQUARE, LEVEL, AND PLUMB. CLEAN &PREP EXISTING WALLS AS NEEDED FOR NEW FINISH INSTALLATION AS PER MFR. RECOMMENDATIONS. C. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS &EXISTING CONDITIONS PRIOR TO COMMENCING WORK. IF ANY DISCREPANCIES EXIST,. CONTRACTOR SHALL NOTIFY PROJECT MANAGER IMMEDIATELY. D. COORDINATE ALL WORK WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. IF DISCREPANCY EXISTS, CONTACT PROJECT MANAGER. E. UNLESS NOTED OTHERWISE, ALL MATERIAL AND EQUIPMENT WILL BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. THIS NOTE APPLIES TO ALL DRAWINGS. F. INTERIOR STUD WALLS SHALL. EXTEND FROM FLOOR TO BOTTOM OF TRUSSES. 4" (NOM.) STUD WALLS TO BE CONSTRUCTED OF 3625125-30 METAL STUDS AND 6" (NOMJ STUD WALLS TO BE CONSTRUCTED OF 550S125-30 METAL STUDS INCLUDING BOTTOM PLATES WITH HORIZONTAL BLOCKING BETWEEN STUDS AT MID -POINT BETWEEN FLOOR AND CEILING UNLESS OTHERWISE NOTED. ALL STUDS SHALL BE SPACED AT 16" O.C. WITH %"MINIMUM SHEATHING OF PLYWOOD, AND / OR GYPSUM BOARD. SHEATHING SHALL EXTEND FROM Y2' ABOVE FLOOR SLAB TO 8" (MIN.) ABOVE ADJACENT CEILING LINE. G. WOOD BLOCKING OR ACX PLYWOOD SHALL BE INSTALLED BEHIND ALL WALL -MOUNTED EQUIPMENT, FIXTURES, SHELVING, AND RACKS. ALL WOOD BLOCKING TO BE FRT. H. ALL PLYWOOD ON THE INTERIOR SHALL BE ACX EXTERIOR GRADE. INSTALL w/ THE SANDED -SIDE OUT. FASTEN WITH #Sxi-15/16" PHILLIPS TRUMPET HEAD SCREWS BY ITN/ BUILDEX OR EQUAL INTO METAL STUDS OR FRAMING MEMBERS AT 16" O.C. MAX. I. THE CABINET VENDOR SHALL FURNISH SHOP DRAWINGS TO THE SPEEDWAY FIELD REPRESENTATIVE FOR HIS REVIEW PRIOR TO FABRICATING. J. ALL RESTROOM ACCESSORIES SHALL BE MOUNTED WITH VANDAL -RESISTANT METAL FASTENERS INTO WOOD BLOCKING. K. ALL GYPSUM BOARD ON RESTROOM CEILINGS SHALL BE 5/8" WATER RESISTANT GRADE. L. ANY INSULATION CONCEALED IN WALLS SHALL HAVE A FLAME SPREAD OF 25 MAX. M. COOLER PANELS SHALL CONFORM TO FM 4880, UL 1040, NFPA 286 OR UL 1715. N. WALK-IN BOX MANUFACTURER SHALL DESIGN ANCHORAGE OF EXTERIOR OR PARTIALLY -EXTERIOR BOXES. COORDINATE REQUIREMENTS WITH GENERAL CONTRACTOR AND ANCHORAGE POINTS AVAILABLE ON SITE. )FLOOR PLAN LEGEND SEE CONSTRUCTION FLOOR PLAN � NEW INTERIOR WALLS -SEE WALL �l NOTES TYPES OSEE DOOR SCHEDULE &DETAILS, = NEW COOLER WALL SHT A7 CONTRAC7C3R COPY THE, GiSlAg ,41,1p ALL RROPOSfsD WOrif& lanE SUBJECT TO ANY COflRECrICrJS RcQUiflL'D BY PIELfO MSPEC'PDRS THAT raav 13E NEcP9SA4ly 111 QAM ro COMPLY WITH ALL APPLICABLE C©DES, 7007 DISCOVERY BLVD DUBLM, OH 43017 614.634.7000 T WOPARTNERS.COM MAY 2 2 2010 OQI I I I Ip3.1 yw �o r, Lei U � � co T J Z ® 0- C7 � U = U) J STORE OR ��tC)� BLDG NO. a VERSION OR AFE NO. . SOSALE: �0 DESIGN TEAM DATE DGNR. J. YOUST 05-22-2015 PM./DP. D. TIMMER 05•22-2015 RVR./DP'. B. BUZARD 05-22.2015 f717tyLe#>•5a] AM SCALE: NONE CEILING CONSTRUCTION PLAN NOTES: 1, EXISTING SOFFIT TO REMAIN. vw 2. EXISTING ACT CEILING GRID AND TILES TO REMAIN, REPLACE DAMAGED/DIRTY TILES. 3. NEW ACT CEILING TILES WITHIN EXISTING CEILING GRID. REFER TO LEGEND FOR TILE TYPE. 4. NOT USED 5. NOT USED 6. EXISTING DIFFUSER / GRILLE. REFER TO MECHANICAL DRAWINGS. 7. NOT USED 8. EXISTING LIGHT FIXTURES. REFER TO ELECTRICAL DRAWINGS. 9. NEW OR RELOCATED LIGHT FIXTURES. REFER TO ELECTRICAL DRAWINGS. 7007 DISCOVERY BLVD 10. EXISTING EMERGENCY LIGHT. REFER TO ELECTRICAL DRAWINGS. DUBLIN, OH 43017 11. NEW OR RELOCATED EMERGENCY LIGHT. REFER TO ELECTRICAL DRAWINGS. 614.634.7000T MEN HALL UTILITY 12. NOT USED WDPARTNERS.COM 13. EXISTING BARREL VAULTED CEILING TO REMAIN. 14. PROVIDE PROTECTIVE LAMP SLEEVES FOR THIS FIXTURE. 8' p" 9'-4" 15. EXISTING EXTERIOR SOFFIT LIGHT FIXTURES TO REMAIN. 16, LINE OF COOLER WALL, OF FAO 2 6 8: 2 B 8 2 6 8 17. EXISTING COOLER/FREEZER EVAPORATORS TO REMAIN. �P�(G 18. NEW COOLER EVAPORATOR, SEE MECH. DWGS. NOT USED O 4/ _ 19. • F -`7120. REPAIR SOFFIT/CEILING TO MATCH EXISTING WHERE COLUMN COVERS HAVE BEEN REMOVED. " 21. NOT USED 2 6 8 TYP SALES AREA UNO TYP SALES AREA UNV BRACING AS PER 01 CEILING CONSTRUCTION PLAN GENERALNOTES SCALE: 114" = 1'-0" 3-5/8" METAL STUDS @ 16" O.C. SUSPENDED ACOUSTICAL DROP CEILING - �6 DROP CEILING SEE CLG PLAN Y"1 %"GYPSUM BOARD, -� PAINTED BTM BULKHEAD 107 -2 2x CONT. WOOD PLATE 11 FINISH FLOOR 100'-0 SUSPENDED ACOUSTICAL DROP °O CEILING DROP CEILING J� SEE CLG PLAN 1/2" STEEL ALL THREAD HANGER ROD W/ DEL NUT & WASHERS @ 48" O/C %"GYPSUM BOARD, PAINTED OZBULKHEAD DETAIL SCALE: 1/2" = 1'-0" SECTION DETAIL BOTTOM CHORD OF JOIST SLIP TRACK SECTION TOP OF METAL STUD WALL. NOTE: WALL MUST BE FREE TO MOVE VERTICALLY WITHIN OVERSIZED CEILING TRACK STOP GYPSUM BOARD 8" ABOVE CEILING CEILING 5/8" GYPSUM BOARD ON STUD CLOSURE FRAMING ABOVE TOP OF COOLER COOLER PANELS SHALL CONFORM TO FM 4880, UL 1040, NFPA 286 OR UL 1715 1/2" GYPSUM BOARD ADHERED TO EXPOSED FACE OF COOLER WALLS BEFORE INSTALLING DOOR FRAMES 03 WALL CLOSURE AT COOLER SCALE: 1/2" = 1'-0" SECTION DETAIL CEILING PLAN GENERAL NOTES: A. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIALS AND EQUIPMENT REQUIRED FOR A COMPLETE INSTALLATION PER ALL APPLICABLE CODES AND THESE DRAWINGS, UNLESS OTHERWISE NOTED. B. CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIALS NECESSARY TO PROVIDE A COMPLETE AND SERVICEABLE SUSPENDED CEILING SYSTEM. MAY 2 2 2015 C. AREAS WITHOUT GRID REFERENCE DIMENSIONS ASSUME 2' x 2' OR 2' x 4' GRID LAYOUT CENTERED WITHIN MAJOR DIMENSIONS OF ROOM AND ORIENTED AS SHOWN. D. BULKHEADS SHALL EXTEND TO BOTTOM OF TRUSSES. 4" (NOM.) STUD WALLS TO BE CONSTRUCTED OF 362S125-30 METAL STUDS AND 6" (NOM.) STUD WALLS TO BE CONSTRUCTED OF 550S125-30 METAL STUDS. ALL STUDS SHALL BE SPACED AT 16" O.C. WITH %- MINIMUM SHEATHING OF PLYWOOD, AND / OR GYPSUM BOARD. SHEATHING SHALL EXTEND TO 8" (MIN.) ABOVE ADJACENT CEILING LINE. CONTRACTOR TO PROVIDE SUFFICIENT BRACING FOR SUPPORT OF BULKHEADS. Q. E. INSTALL WATER RESISTANT GYPSUM BOARD CEILING IN RESTROOMS, IF NEEDED. 0 0 F. REMOVE SUSPENDED CEILING SYSTEM AS REQUIRED FOR ABOVE -CEILING WORK. REPLACE TILES AND GRID, OR REPLACE WITH NEW TO MATCH EXISTING c IF SYSTEM IS DAMAGED. 4 O 7 N C O mm 'OA. u) t6 Ty �o 0 ACOUSTICAL CEILING NOTES: wMrr a` N w w 1. ALL CEILING TILES AND SUSPENSION: SYSTEM WILL BE SUPPLIED BY ACOUSTICAL AND INTERIOR DISTRIBUTORS, INC. CONTRACTOR SHALL PLACE TILE ORDERS BY CONTACTING: ACOUSTICAL & INTERIOR DISTRIBUTORS, INC. 6186 CENTRE PARK DRIVE WEST CHESTER, OHIO 45069 513/779-9229 (FAX) ATTN: BRUCE KOEHN AND GREG HUMBERT 800-875-9200 MARATHON JOB QUOTE #CCA920 2. SUSPENSION SYSTEM: 15/16" FACE FULLY EXPOSED WITH SINGLE FLANGE CHANNEL EDGE MOLDING AND 1-1/2" DEEP MAIN RUNNERS. EQUAL TOE. ARMSTRONG FIREGUARD GRID SYSTEM. FINISH TO BE BAKED WHITE ENAMEL, UNLESS OTHERWISE NOTED. 3. CEILING TILES: REFER TO LEGEND BELOW. � oa w a y3 0. w mn w 00 �a 80 w Z. � ZZ' o EN �p w �p z 6 ¢w x .3 a y,o ON w CONTRACTOR COPY ¢ww w Z o O aO y wx > xr '3: 0w REFLECTED CEILING LEGEND: ZU <O om ® EXISTING 1 X 4 TROFFER, OPEN ( EXISTING CEILING -MOUNTED CAMERA �o. e PARABOLIC DIFFUSER �! o EXISTING 2 X 4 TROFFER, OPEN � EXISTING THERMOSTAT PARABOLIC DIFFUSER z N NEW 2 X 4 TROFFER - PROVIDE TUBE SLEEVES IN TYPE B/D CEILING AREAS EXISTING CEILING -MOUNTED SPEAKER z L'1 J � EXISTING 2 X 2 TROFFER WITH Q�,i �" _ rn CLOSED PRISMATIC LENS a EXISTING EXIT / EMERGENCY LIGHT z U J QQQQ C 0 T LL EXISTING 2 X 2 TROFFER WITH OPEN z Q LLI PARABOLIC DIFI"USER - PROVIDE dH EXISTING EXIT LIGHT U SLEEVES IN TYPE B/D CEILING AREAS J V Q EXISTING DOWNLIGHT NEW CEILING TILE/NEW GRID V _ EXISTING TILE/EXISTING GRID fn Kn ® NEW DOWNLIGHT z EXISTING STRIP LIGHT 0 �� AREA OF NEW CEILING TILE Oco CD NEW STRIP LIGHT IN EXISTING GRID V EXISTING GASKETED LIGHT FIXTURE QR ® SUPPLY DIFFUSER. STORE oR 6 A H5 EXISTING WALL -MOUNTED LIGHT SEE MECH. DWGS. BLDG NO. u�} VERSION NEW WALL -MOUNTED LIGHT RETURN OR Z ® SEE MECH.RDWGS.UST GRILLE OR ALE NO. NEW LED LIGHT, REFER TO ELECTRICA --��� SCALE: 0- 4 TYPE "A" SUSPENDED CEILING (24x48x5/8") TYPE "C" SUSPENDED CEILING (24"x24"x5/8") ARMSTRFISSURE ARMSTRONG ITEM #1728, FINE FISSURED,DATE CLASS AO(UL), NG ITEM TE,, SUSP NSION SYSDEM, C PCLASS ARELUDE 115/16 EXPOSED S T. NSION SYSTEM, THESE PUNS AND ALL PROPOSSD WORK DESIGN N TEAM J. YOUST 0522.2015 PRELUDE 1.5/16" EXPOSED T. ARE SUBJECT TO ANY COMECTICN i DGN REQUIRED BY PIELD INSPECXRS THAT PM./DP. D. TIMMER 05-ZZ-2015 TYPE "B" SUSPENDED CEILING (24"x48"x5/8")DCLEAN TYPE "D' SUSPENDED CEILING (24"x24"x5/8") MAY BE NECISsAmy IN ORM TO RVR./oP. B. BuzARD os-z2.za15 ARMSTRONG ITEM #793, GEORGIAN, ARMSTRONG ITEM #794, GEORGIAN, CLASS A (UL), WHITE, SUSPENSION SYSTEM,CLASS A (UL), WHITE, SUSPENSION SYSTEM, COMPLY WITH ALL APPLICABLE CODES, DRWG. No. B CLEAN ROOM SYSTEM, 15/16" T. ROOM SYSTEM, 15/16" T. A-2 FINISH PLAN NOTES: FINISH PLAN GENERAL NOTES: 01 FINISH PLAN® SCALE: 1/4" = 1'-0" FLOOR AND WALL FINISHES & ACCESSORIES SCHEDULE REF DESCRIPTION SIZE COLOR ORDER NO. GROUT CT-X CERAMIC FLOOR TILE 12"x12" EXISTING --- --- CT-iX CERAMIC FLOOR TILE 12"x12" WHITE - CROSSVILLE TO MATCH CT-2X CERAMIC FLOOR TILE: 12"x12" GRAY CROSSVILLE TO MATCH CT-3X CERAMIC FLOOR TILE 12N12" GREEN CROSSVILLE TO MATCH M 11 ANTI -FATIGUE MAT CUSTOM GRAY #489, 12K4 CUT F7A VINYL COVE BASE 4" MATCH EXISTING --- FRP-1 WASHABLE FIBERGLASS 4'x8', x10', x12' WHITE REINF. POLYESTER PANELS FRP-2 WASHABLE FIBERGLASS 4'x8', x10', x12' LIGHT GREY REINF. POLYESTER PANELS Fp CORNER GUARD 2"x2N48" LENGTH STAINLESS STEEL CG-51-48 - SERIES 160C V-1 3M CONTROLTAC PLUS GRAPHIC FILM ARDEX K301 SELF -LEVELING T-1 CEMENT -BASED TOPPING FINISH NOTES PLASTIC LAMINATE & CABINET FINISHES SCHEDULE 6 REF PROTO DESCRIPTION MFR COLOR ORDER # FINISH SCHED NOTES 6 SS-1 V3900 1/2" STAINLESS STEEL #D315-TMO51 12,11 6 F-1 V3900 SOLID SURFACE WILSONART #1530-TM 12,11 6 F-2 V3900 PLASTIC LAMINATE WILSONART (MAROON) #4662-60 12,11 7 F-3 V3900 PLASTIC LAMINATE WILSONART NATURAL PEAR - MATTE #D7061-60 12,11 2 3,4 F-4 NOT USED. V3900 PLASTIC LAMINATE WILSONART BLACK #1595-60 12,11 3,4 F-5 V3900 PLASTIC LAMINATE PIONITE WINTER WHITE #SW-836 8 F-6INATE WHITE CABINET CLASS "A" F-7 V3900 PLASTIC LAMINATE LINER V3900 PLASTIC LAMINATE PIONITE FOLKSTONE GREY #SG-241 NON -SLIP FINISH & F-9 CLEAR SEALER 1. EXISTING FLOOR TILE TO REMAIN. A. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIALS AND EQUIPMENT 2. PATCH/REPLACE FLOOR TILE TO MATCH EXISTING, REFER TO ROOM FINISH REQUIRED FOR A COMPLETE INSTALLATION PER ALL APPLICABLE CODES AND THESE SCHEDULE. DRAWINGS, UNLESS OTHERWISE NOTED. 3. EXISTING VCT TO REMAIN. B. ALL EXISTING. FLOORS, WALLS, OR OTHER SURFACES TO RECEIVE A FINISH MATERIAL 4. NOT USED SHALL BE MADE SQUARE., LEVEL, AND PLUMB. 5. NOT USED C. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCING 6. NOT USED WORK. IF ANY DISCREPANCIES EXIST, CONTRACTOR SHALL NOTIFY PROJECT ' MANAGER IMMEDIATELY. 7. NOT USED D. UNLESS NOTED OTHERWISE, ALL MATERIAL AND EQUIPMENT WILL BE FURNISHED AND 8. NEW ANTI -FATIGUE MAT. INSTALLED BY THE GENERAL CONTRACTOR. THIS NOTE APPLIES TO ALL DRAWINGS. 9. EXISTING SEALED CONCRETE TO REMAIN. E. NOT USED. 10. PAINT ALL EXPOSED GYPSUM BOARD. F. CONTRACTOR TO. VERIFY WITH PROJECT MANAGER ALL WALLS, DOORS, AND FRAMES 11. INSTALL STEEL CORNER GUARDS ON ALL OUTSIDE CORNERS, TYP. REFER TO TO BE PAINTED. FLOOR AND WALL FINISHES & ACCESSORIES SCHEDULE G. ALL "SCHEDULE FINISH MATERIAL" AND THE CORRESPONDING "ROOM. FINISH SCHEDULE 12. NOT USED NOTES" MAY NOT APPLY TO THE SCOPE OF WORK. THE FINISH MATERIALS ARE SHOWN 13. NO WORK IN THIS AREA. FOR. REFERENCE FOR ANY ADDITIONAL WORK THAT MAY BE REQUESTED OR REQUIRED 14. PAINT ONLY AT DIRECTION OF PROJECT MANAGER. OUTSIDE THE SCOPE OF WORK. 15. PAINT EACH SIDE OF DOOR AND FRAME TO MATCH ADJACENT WALLS. NOTE THAT H. PREP & CLEAN. ALL SURFACES BEFORE APPLYING NEW FINISHES. EACH SIDE OF DOOR MAY DIFFER IN COLOR. 16. DO NOT PAINT BEHIND TAN GRAPHICS PANELS. TAPE EDGES AND PAINT PER PLAN. A KEY PLAN KE 1 PAINT SCHEDULE SEE FINISH PLAN P1 "SHERWIN-WILLIAMS" #EXTRA WHITE (WHITE) CONSTRUCTION NOTES Q P2 "SHERWIN-WILLIAMS" #SW2130 - PERMA. WHITE SEE SCHEDULES THIS SHEET P3 "SHERWIN-WILLIAMS" #7034 STATUS BRONZE AREA OF NEW SLAB P4 "SHERWIN-WILLIAMS" #SW4056 - (TO MATCH AND CERAMIC TILE PMS-249C'BLUE' - MFD BY BREAK THROUGH) AREA OF NEW TILE p5 "SHERWIN-WILLIAMS"#SW7031-MEGA GRAIGE. ON EXISTING SLAB P6 "SHERWIN-WILLIAMS" #SW7029 -AGREEABLE GRAY ROOM FINISH SCHEDULE NOTES. P7 .SHERWIN-WILLIAMS"#SW6105 DIVINE WHITE 1. ALL FLOOR & WALL TILE WILL BE MANUFACTURED BY CROSSVILLE. 2. 4" VINYL COVE BASE MANUFACTURED BY ROPPE CO. 3. FIBERGLASS REINFORCED POLYESTER (FRP) PANELS ARE CLASS AMATERIAL, MANUFACTURED BY MARLITE OR NUDO PRODUCTS. CONTRACTOR TO PLACE ORDER BY CONTACTING: MARLITE (ORDER FRP FRP-1: #P-100, COLOR=WHITE & FRP-2: #P-151, COLOR=LIGHT GREY) DOVER, OHIO 44622 CONTACT: (330) 343-6621 OR NUDO PRODUCTS (ORDER FIBER-LITE .090 LINER #LP-F9, FRP-1: COLOR WHITE 050 & FRP-2: COLOR LIGHT GREY 750) 1500 TAYLOR AVE SPRINGFIELD, ILLINOIS 62703 CONTACT: MARK SIMPSON (800) 826-4132 4. CONTRACTOR SHALL PROVIDE NECESSARY TRIMS, CLOSURES AND ACCESSORIES. FOR A FINISHED INSTALLATION, 5. FLOOR GROUT TO BE PROVIDED BY: CUSTOM BUILDING PRODUCTS 13001 SEAL BEACH DRIVE SANTA MONICA, CA 90740 THE l',LA1'VS AND ALL PROPOSSO 1,YUF�I•� PHONE: 562-598-8808 ARE SUBJECT TO ANY COMECTICNS, 6. GROUT TO MATCH EXISTING. REQUIRED BY FIC-LID lNSAECIioR.S'I'� 7. ANTI -FATIGUE MAT SHALL BE WEARWELL "ERGO -STANCE" #489 AS MANUFACTURED BY: MAY BE NECLOBSA r�RY IN O RiDM 10 TENNESEE MAT COMPANY, INC. COMPLY WITH ALL APPLICABLE CUD<7', , 1414 FOURTH AVENUE SOUTH NASHVILLE, TN 37210 PHONE: 800-264-3030 MAT DIMENSION IS CUSTOM WIDTH WHICH MUST BE END -TRIMMED TO MEET BOUNDARY OF TILE. MATS SHALL BE FITTED SO AS TO PROVIDE FULL COVERAGE OF ATTENDANT AREA WITH MAT -TO -TILE JUNCTION BUTTED TIGHTLY AND FIRMLY ADHERED,. SO AS TO PREVENT A TRIPPING HAZZARD. 8. CORNER GUARD FURNISHED AND INSTALLED BY CONTRACTOR PER MANUFACTURS INSTRUCTIONS. PLACE ORDER BY CONTRACTING PAWLING CORPORATION PHONE (914) 373-8712. INSTALL ON ALL OUTSIDE CORNERS. 9. ALL FLOOR TILE GROUT SHALL BE SEALED WITH AQUA MIX GROUT SEALER. (800) 366-6877. SEALANT SHALL BE APPLIED TO THE GROUT ONLY. FLOOR TILE NOT TO BE SEALED. 10. INSTALL ALUMINUM TRANSITION EDGE AT DOOR OPENINGS. EDGE IS MODEL TRANZ 1132 BY CERAMIC TOOL COMPANY, INC. 11. INTERIOR LAMINATED WINDOWSILLS PROVIDED BY CABINET VENDOR INSTALLED BY CONTRACTOR. LAMINATE MANUFACTURED BY WILSONART. 12. CABINET FINISH: MATERIAL, MANUFACTURED BY WILSONART. CABINETS TO BE FABRICATED & SUPPLIED BY CABINET VENDOR. CABINETS FINISHES MAY ONLY APPEAR ON CABINET DRAWINGS AS PREPARED BY CABINET VENDOR. 13. CONTRACTOR SHALL FURNISH AND INSTALL AN ELASTORMERIC ANT -FRACTURE MEMBRANE OVER ALL CONTROL JOINTS AND SHRINKAGE CRACKS ON ALL AREAS RECEIVING CERAMIC FLOOR TILE. AVAILABLE PRODUCTS INCLUDE: LEVEL QUIK WATERPROOFING & ANTIFRACTURE MEMBRANE CUSTOM BUILDING PRODUCTS PHONE: 800-272-8786 OR HYDROMENT ULTRA -SET CRACK ISOLATION. MEMBRANE _ BOSTIK FLOORING PHONE: 800-726-7845 CONTRACTOR COPY 14. PROVIDE NEW TILE WHERE TILE WAS REMOVED DUE TO DEMOLITION. 15. ENTRANCE FLOOR MAT BY SPACE LINKS INTERNATIONAL. PRODUCT LINE IS DESIGN LINKS 11. MAT IS FLEXIBLE,INJECTION MOLDED, PVC MODULES SURROUNDED BY 0.75"xO.50" ANODIZED ALUMINUM FRAMES, THE SYSTEM PROVIDES 1.125" HORIZONTAL REMOVABLE CARPET STRIPS EVERY 1.25". MAT TO BE INSTALLED IN 0.50" DEEP, SMOOTH, HARD SURFACE WELL. INCLUDE ALL APPROPRIATE ANCHORS AND FASTENERS TO INSTALL SYSTEM COMPLETE. CONTRACTOR. TO SUPPLY. ROOM FINISH SCHEDULE ROOM I I FLOOR BASE WALLS CEILING c p ��� J�� �QQ C 2 2? 5 v 2 JQ� P cj REMARKS SEE ROOM FINISH SCHEDULE NOTES #15 SEE ROOM FINISH SCHEDULE NOTES-#7 FLOOR. IS VCT. FINISH RM AT DISCRETION OF PM FLOOR IS VCT. FINISH RM AT DISCRETION OF PM SEE ROOM FINISH SCHEDULE NOTES#15 FINISH ROOM AT DISCRETION OF PM SEE ROOM FINISH SCHEDULE NOTES #15 PAINT CEILING AND TOP 1.2" OF WALL P4. 0 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM MAY 2 2 2015 N 0 C O Y U 7 N 0 O clj M N IM 'OA Ts� mma�_ v(D=tj n AI u0 V)WW y Lu J � N Z p O'* J W I-i LL U <Ly - T J Z U) cn U) C F7 b 0 NO 6485 AFE NO. 1LE: I IDESIGN TEAM I DATE II DGNR. J. YOU6T OS-22-2015 PM./DP. D. TIMMER OS-22-2015 RVRJDP. B. BUZARD 05.22.2015 DRWG. NO. A-3 E F ol PIPE FLASHING SCALE: 3" = l'-O" SECTION DETAIL THESE PLANS AND ALL PROPOS50 WORK ARE SUBJECT TO ANY COMECTICNS REOUIRLD BY FIELD RJSPEC70RS THAT 14 AY BE NECMAtY IN ORDM TO COMPLY WITH ALL APPLICABLE CODES, 7007 DISCOVERY BLVD DUBLIN, ON 43017 614.634.7000 T WDPARTNERS.COM K. MAY 2 2 2015 N VJ � ff O? J 0 M Q J r u- <L w Q 2 :D LL (D J o co 0 Z)� OO 19 a - CD E O BLDGNO.. 6485 LDG VERSION OR AFE NO. SCALE: DESIGN TEAM DATE DGNR. J. YOUST 05-22.2015 PM./DP. D. TIMMER 05-22-2015 RVR./DP. B. BUZARD 05-22.2015 DRWG. NO. A- 4.1 EXISTING METAL ROOF EXISTING MASONRY EXISTING GLAZING 'EXISTING STAINLESS TO REMAIN STEEL COVER REPLACED WITH NEW STONE VENEER. 03 SEE DETAILS AND A7 SECTIONS, SHEET olFRONT ELEVATION SCALE: 3/16" = 1'-0" OZRIGHT ELEVATION SCALE: 3/16" = 1 °-0" 03 REAR ELEVATION SCALE: 3/16" = 1 °-0" A7 EXISTING STAINLESS STEEL COVER REPLACED WITH NEW EIFS. SEE DETAILS AND SECTIONS, SHEET A7. we EXISTING EIFS SIGN BAND EXISTING EIFS _ EXISTING METAL ROOF EXISTING EIFS SIGN BAND EXISTING MASONRY EXISTING METAL ROOFBEYOND EXISTING EIFS EXISTING EIFS SIGN BAND EXISTING EIFS 04 LEFT ELEVATION SCALE: 3/16" = 1'-0" EXISTING METAL ROOF STING MASONRY md 7007 DISCOVERY BLVD DUBLIN, OR 43017 614.634.7000 T WDPARTNERS.COM �OF'FL—N, ZrA ill MAY Sea9, 2015 .: a d 0 0 0 Y N 0 0 O P9 04 RM toLo a C a�T do y 0 = '050 �a(AWW N z 0 U) Z O _ F- N Lr) Q � M T LL L u I Q LU Lu = ry (j J O ry _ F— LU 60 ��/ (.0 0— �/ X L L] STORE OR BLDG NO. 6485 VERSION OR AFE NO. SCALE: DESIGN TEAM DATE DGNR. J. YOUST 05-22-2015 PM./DP. D. TIMMER 05-22.2015 RVR./DP. B. BUZARD 05.22-2015 DRWG. NO. A- 5 EXTERIOR FINISH SCHEDULE CEMENT PLASTER HIGH VELOCITY HURRICANE ZONES MANUFACTURER: STO CORPORATION STYLE: STO POWERWALL HI WALL PANEL SYSTEM COLOR: MATCH EXISTING NOA NO: 12-0821.15 CEMENT PLASTER NON -HIGH VELOCITY HURRICANE ZONES MANUFACTURER: STO CORPORATION STYLE: STO POWERWALL COLOR: MATCH EXISTING ICC-ES: ESR-2323 CULTURED STONE (STONE VENEER) MANUFACTURER:BORAL STYLE: PRO -FIT LEDGESTONE COLOR: PLATINUM FL NO: FL15047-R2 ICC-ES: ESR-1364 EXTERIOR INSULATION FINISH SYSTEM HIGH VELOCITY HURRICANE ZONES MANUFACTURER: DRYVIT STYLE: OUTSULATION OF SYSTEM COLOR: MATCH EXISTING NOA NO: 12-0312.04 FL NO: FL2030-R6 EXTERIOR INSULATION FINISH SYSTEM NON -HIGH VELOCITY HURRICANE ZONES MANUFACTURER: DRYVIT STYLE: OUTSULATION SYSTEM COLOR: MATCH EXISTING FL NO: FL3423-R4 ICC-ES: ESR-1232 - SEALANT 1N EIFS ON 1" RIGID INSULATION BOARD EXTERIOR GRADE CEMENTBOARD TRTD 2x4 WOOD FRAMING w EXTERIOR GRADE CEMENTBOARD EIFS ON 1" RIGID — INSULATION BOARD FLASHING & SEALANT (COLOR TO MATCH EIFS) THIN SET STONE VENEER ON MORTAR BED Y HEAD DETAIL SCALE: 3" = 1'-O" SECTION DETAIL 05 EIFS SILL FLASHING SCALE: 3" = 1'-0" SECTION DETAIL V EXTERIOR GRADE CEMENTBOARD THIN SET STONE VENEER MORTAR BED FLASHING & SEALANT Uw to � p> g L 04WALL BASE SCALE: 3" = 1'-0" N SECTION DETAIL 03 SECTION AT COLUMN SCALE: 1" = 1'-O" EXISTING INTERIOR — GYP. BD. SHEATHING TO REMAIN TRTD 2X4 SHOT INTO EXISTING 3" X 3" TUBE STEEL W/ HILT[ X-U52 KNURLED SHANK FASTENERS @ 6" O.C. VERTICALLY. TRTD 2X4 SCREWED AND GLUED TO 2X4 W/ 2 1/2" SELF EXISTING 3x3 TUBE STEEL EXISTING ALUMINUM STOREFRONT & GLAZING RUBBER BACKER ROD AND SEALANT (TYP.) LINE OF EIFS OR STUCCO ABOVE TAPPING WOOD SCREWS @ 6" MORTAR BED O.C. THIN SET STONE VENEER 02 PLAN AT EIFS COLUMN z SCALE: 1" PLAN DETAIL w VIF EXISTING INTERIOR ¢ 3„ 6„ �, GYP. BD. SHEATHING L TO REMAIN EIFS ON 1" RIGID INSULATION BIDS — 1/2" EXTERIOR GRADE CEMENT BOARD ALIGN FACE OF BD WITH BACK SIDE OF EXISTING STOREFRONT FRAMING 01 THE, PLANS AND ALL PROPOSO WORK ARE SUBJECT TO ANY CORRECTICNS REQUIRED BY FIELD INSPECIORS THAT GIAY BE NECINANY IN OFSDL'IR TO COMPLY WITH ALL APPLICABLE CODES. PLAN AT STONE SCALE: 1" = 1'-O" PLAN DETAIL RUBBER BACKER ROD AND SEALANT (TYP.) — TRTD 2X4 SHOT INTO EXISTING 3" X 3" TUBE STEEL W/ HILTI X-U52 KNURLED SHANK FASTENERS @ 6" O.C. VERTICALLY. — TRTD 2X4 SCREWED AND GLUED TO 2X4 W/ 2 1/2" SELF TAPPING WOOD SCREWS @ 6" O.C. BASE CONTRACTOF; COPY 0 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM EOF I a K. MAY 2 2 2015 r+ O. d 0 O Y U N C U cq bA TCo m0`y= aID N4) too �yCC m Mac c �aNWW y ow Q W w UU = N F a) OCO r —1 LL Q LU 2 5 0cn J Z) H- 0fr C BLDG NOR 6485 1 VERSION OR AFE NO. SCALE DESIGN TEAM DATE DGNR. J. YOUST 05-22-2015 PM./DP. D. TIMMER 05.22-2015 RVR./DP. B. BUZARD 05.22-2015 DRWG. NO. A-7 w EXTERIOR GRADE CEMENTBOARD EIFS ON 1" RIGID — INSULATION BOARD FLASHING & SEALANT (COLOR TO MATCH EIFS) THIN SET STONE VENEER ON MORTAR BED Y HEAD DETAIL SCALE: 3" = 1'-O" SECTION DETAIL 05 EIFS SILL FLASHING SCALE: 3" = 1'-0" SECTION DETAIL V EXTERIOR GRADE CEMENTBOARD THIN SET STONE VENEER MORTAR BED FLASHING & SEALANT Uw to � p> g L 04WALL BASE SCALE: 3" = 1'-0" N SECTION DETAIL 03 SECTION AT COLUMN SCALE: 1" = 1'-O" EXISTING INTERIOR — GYP. BD. SHEATHING TO REMAIN TRTD 2X4 SHOT INTO EXISTING 3" X 3" TUBE STEEL W/ HILT[ X-U52 KNURLED SHANK FASTENERS @ 6" O.C. VERTICALLY. TRTD 2X4 SCREWED AND GLUED TO 2X4 W/ 2 1/2" SELF EXISTING 3x3 TUBE STEEL EXISTING ALUMINUM STOREFRONT & GLAZING RUBBER BACKER ROD AND SEALANT (TYP.) LINE OF EIFS OR STUCCO ABOVE TAPPING WOOD SCREWS @ 6" MORTAR BED O.C. THIN SET STONE VENEER 02 PLAN AT EIFS COLUMN z SCALE: 1" PLAN DETAIL w VIF EXISTING INTERIOR ¢ 3„ 6„ �, GYP. BD. SHEATHING L TO REMAIN EIFS ON 1" RIGID INSULATION BIDS — 1/2" EXTERIOR GRADE CEMENT BOARD ALIGN FACE OF BD WITH BACK SIDE OF EXISTING STOREFRONT FRAMING 01 THE, PLANS AND ALL PROPOSO WORK ARE SUBJECT TO ANY CORRECTICNS REQUIRED BY FIELD INSPECIORS THAT GIAY BE NECINANY IN OFSDL'IR TO COMPLY WITH ALL APPLICABLE CODES. PLAN AT STONE SCALE: 1" = 1'-O" PLAN DETAIL RUBBER BACKER ROD AND SEALANT (TYP.) — TRTD 2X4 SHOT INTO EXISTING 3" X 3" TUBE STEEL W/ HILTI X-U52 KNURLED SHANK FASTENERS @ 6" O.C. VERTICALLY. — TRTD 2X4 SCREWED AND GLUED TO 2X4 W/ 2 1/2" SELF TAPPING WOOD SCREWS @ 6" O.C. BASE CONTRACTOF; COPY 0 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM EOF I a K. MAY 2 2 2015 r+ O. d 0 O Y U N C U cq bA TCo m0`y= aID N4) too �yCC m Mac c �aNWW y ow Q W w UU = N F a) OCO r —1 LL Q LU 2 5 0cn J Z) H- 0fr C BLDG NOR 6485 1 VERSION OR AFE NO. SCALE DESIGN TEAM DATE DGNR. J. YOUST 05-22-2015 PM./DP. D. TIMMER 05.22-2015 RVR./DP. B. BUZARD 05.22-2015 DRWG. NO. A-7 XISTING PARTITION 1/2" METAL FURRING '2" GYPSUM BOARD ,DHERED TO COOLER JALLS COOLER WALL CLOSURE 04 SCALE: 1 1/2" = 1'-0" PLAN DETAIL COOLIE COOLER SHELL REACH -IN COOLER DOOR SILL WALL BY COOLER MFR. —� SALES DRYWALL PAINTED, SEE FINISH PLAN TOP OF DOOR107' FRAMED, -2" PERIMETER DOOR FRAME DRYWALL PAINTED, SEE FINISH PLAN VINYL COVE BASE C FINISHED 1 03 COOLER SILL DETAIL SCALE: 12" = 1 SECTION DET (L NOTE: INSULATION SHOWN FOF COOLER BOTTOM CHORD OF JOIST SLIP TRACK SECTION TOP OF METAL STUD WALL. NOTE: WALL MUST BE FREE TO MOVE VERTICALLY WITHIN OVERSIZED CEILING TRACK STOP GYPSUM BOARD 8" ABOVE CEILING 5/8" GYPSUM BOARD ON STUD CLOSURE FRAMING ABOVE TOP OF COOLER COOLER PANELS SHALL CONFORM TO FM 4880, UL 1040, NFPA 286 OR UL 1715 1/2" GYPSUM BOARD ADHERED TO EXPOSED FACE OF COOLER WALLS BEFORE INSTALLING DOORFRAMES SALES/UTILITY OZWALL CLOSURE DETAIL SCALE:: 1 1/2" = 1'-O" SECTION DETAIL CONTRACTOR COPY THE,. PLAjNS AJND ALL PROPOSSD W01 K ARE SUBJECT TO ANY COMIECTICHS REQUIRED BY PIELD INSPEC70RS THAT r4AY BE NECPNANY IN OR+OM TO COMPLY WITH ALL APPLICABLE CODES. 0 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM OF MAY L 2 2015 Q 0 c 0 N G 0 U CO bA a) too �a(nWW C4 o¢ w� w ma 00 F0 0z zZ �w w z0 <0 w z 0 w Z U) J ~ LO O m Q F_ w J ILL F ® Q W Q 0 S 0 Z U-' ID J o W = F- O Ir W U coo a � STORE OR 6485 BLDG NO. VERSION OR AFE NO. SCALE: 0 4 DESIGN TEAM DATE DGNR. J. YOUST 05-22.2015 PM./DP. D. TIMMER 05-22.2015 RVR./DP. B. BUZARD 05-22.2015 DRWG. NO. A- 8 3 t�D MEN l: WOMEN roil 3' 4 314" STORAGE 9ml STORAGE WIM. TAN PANELS !�HALL DUNKIN � PASTRY � 3 CP.SE 3 rjli=ram ATTENDANT rG1i 124A X 12'-6 V4" 0 11 1060 ( 3 T-0"V.I.F. — -- NEW=ABINET— _ 2 O O 2 2 r� 2 2 � PO. y 34V WALK-IN CAVE v 2 L 12 SALES AREA TAN PANELS . o SIM BM.1 26 LR1 94 42A 4' POP SHELVES O 88E 88E -------I 'F- 30" 10 I ------ WALK-IN 30" 9 COOLER I 30" g 30" 7 I, 30" 6 30,,5 , 30,, 4 30" 3 I I „21 I WALK-IN 30" 1 !COOLER 37 I 1E INTERIOR GRAPHICS MOUNTING GUIDELINES 1. ANCHOR POINTS TO BE SECURED AT 100 POUNDS MINIMUM 2. MOUNT WITH EYEUP BOLTS TO ROOF TRUSS OR STRUCTURALLY ADEQUATE BRIDGING 3DE MATERIAL (SUCH AS SLOTTED ANGLE IRON) ONLY. x 3. NO ANCHORING TO ROOF GRID, MECHANICAL, OR ELECTRICAL BUILDING COMPONENTS. SHEET KEY XXX REFER TO EQUIPMENT SCHEDULE XXX REFER TO SIGNAGE & GRAPHIC SCHEDULE XXX REFER TO WALL MOUNTED SHELVING SCHEDULE w Z 0 0 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM OF a K. MAY 2 2 2015 a m 0 C 0 V 7 a c 0 U M 11 m Uq Tc� mf6m= aD �� E cLnA k_�WWLU° c EQUIPMENT PLAN Lo 01 SCALE: 1 /4" = 1'-O" O) M r J F— } LL z Q W w S (�j J 0- _ � ZD Lu CD 0 CONTRACTOR COPY co a - THEE PLANS AND ALL PROPOSED W02K ARE SUBJECT TO ANY CORRECTICHS REQUIRED BY PIELD NSPEC11ORS THAT MAY BE NECr96AlIY IN CIRO 1l TO COMPLY WITH ALL APPLICABLE CODES, STORE OR 6485 1 BLDG NO. IVERSION OR AFE NO. SCALE AS NOTED DESIGN TEAM DATE DGNR. J. YOUST 05.22-2015 PM./DP. D. TIMMER 05-22-2015 RVR./DP. B. BUZARD 05.22-2015 DRWG. NO. EQ-1 F— T BW3 MW, HDCN T CD4 I EX. C TO BE DEMOI CO L 2 DL3ST 3. HDCN L3ST CD4 SIN 19'-4" 0„ 12,-6„ T-0„ EXISTING COUNTER TO REMAIN NEW COUNTER Tn LnnrnN A HOT DOG & FOUNTAIN CABINETS 5C41 5CFZ SCALE: 1/4" = V-0" ICAL EQUIPMENT INSTALLATION RESPONSIBILITYWOR�PLUMBNG INAL CONTRACCTIONS TORS IN ALL CASES) ITEM NO. DESCRIPTION RESPONSIBILITY CONTRACTOR VENDOR 1 WALK-IN COOLER INSTALL SLEEVES & WIRING FOR EXTERIOR CIRCUITS ON. ADJACENT WALLS x ERECT WALK-IN COOLER X PROVIDE ROOF AND/OR WALL PENETRATIONS REQUIRED FOR REFRIGERANT LINES X SET REMOTE CONDENSING. UNIT x RUN CONDENSATE DRAIN LINE FROM EVAPORATOR COILS TO FLOOR DRAIN X RUN, SECURE AND CONNECT COPPER REFRIGERANT LINES FROM EVAPORATOR COIL TO COND. UNI X START UP OF UNIT x SET POSTMIX DISPENSER, ICEMAKER, S-1-B RACK AND CARBONATORS X 253 POSTMIX PROVIDE ROOF AND/OR WALL PENETRATIONS REQUIRED FOR REFRIGERANT LINES X 25U GAGA -BOX 25W.1 CARBONATORS SET REMOTE CONDENSING UNIT FOR ICEMAKER X RUN CONDENSATE AND DRIP TRAY DRAIN' LINES TO DRAIN X RUN, SECURE & CONNECT REFRIGERATION LINES FROM EVAPORATOR COIL TO CONDENSING UNIT X. 25X BAG -IN -BOX RUN, SECURE AND CONNECT CO2 LINES FROM BULK TANK TO CARRONATORS X 25Y ICE MAKER RUN, SECURE & CONNECT FILTERED WATER LINES TO ICEMAKER, CARBONATORS & POSTMIX DISP SER X ORIENT ICE MAKER SUCH THAT SERVICEABLE PARTS ARE ACCES81BLE X RUN, SECURE & CONNECT SYRUP LINES FROM B-1-B RACK TO POSIMIX DISPENSER START UP OF UNITS X x SET FCB DISPENSER. X 80H(FCB DISPENSER) RUN, SECURE AND CONNECT CO LINE FROM BULK TANK X RUN, SECURE & CONNECT FILTERED WATER LINE x RUN., SECURE & CONNECT SYRUP LINES FROM B-1-B RACK X START UP OF UNIT x EQUIPMENT SCHEDULE: ITEM # QUANTITY MANUFACTURER MODEL NUMBER ITEM DESCRIPTION AND MODEL # ( NOTE: 0 - OWNER, V - VENDOR, C - CONTRACTOR, P - PLUMBER, M - MECHANICAL, & E - ELECTRICIAN) FURN. BY NSTL. BY 1E 2 MODIFIED WALK-IN COOLER 1X EXISTING --- --- WALK-IN COOLER 0 C DISPLAY SHELVING 2* SEE PLAN KENT - GONDOLA SHELVING, END CAPS AND WALL SHELVING 0 C 2B* SEE PLAN -- --- 24" 2-LITER POP SHELVING - AVAILABLE IN 3' AND 4' SECTIONS 0 0 STORAGE & WALL SHELVING 3 SEE PLAN --- -- FREE STANDING STORAGE SHELVING 0 C 3A SEE PLAN OPTION ASTER --- HEAVY DUTY MODULAR STORAGE SHELVING - BEER CAVE - 24"W X 30"D (STD), 24'W X24'D (OPT), 30"D CORNER SECTION (STD) 0 C LR1* 1 - --- LITERATURE RACK 0 0 SR1* 1 - — SPINNER RACK 0 0 SR3* 1 — SUNGLASSES RACK 0 CABINETRY 5C41* 1 NELCO HOT DOG WALL CABINETS - SINGLE GRILL 0 5C97* 1 DISPLAY INDUS. - MAGAZINE AND NEWSPAPER RACK 0 5CFZ 1 NELCO - CUSTOM FOUNTAIN CABINETS 0 ir POS EQUIPMENT 8M* 1 RADIANT P1550 SPEEDY REWARDS REWARD TERMINAL 0 8M.1* 1 FRANK MAYER 9745 ASSY CU SPEEDY REWARDS STAND 0 HOT DOG ROLLER GRILLS9L* 1 NEMCO TBD RETHERMALIZATION DRAWER (HOTDOG WARMER - BULLPEN) O 9Mi* NEMCO 8075SXW-SLT-RC NEMCO ROLLER GRILLS w/NON-SLIP GRIPSLTCOATING (75 CAPACITY) (INCLINED SURFACE) 0 C HOT DOG BUN WARMERS 10i* 1 NEMCO 8027-BW BUN WARMER DRAWER (CAPACITY = 32 BUNS) 0 C HOT DOG SNEEZE GUARDS 11J* 1 STAR 75SG-2D STAR FULL COVER 2DR SNEEZE GUARD FOR NEMCO 75 HOT DOG ROLLER GRILL 0 C MISCELLANEOUS DELI EQUIPMENT 14B* 1 GEHLS CHILI/ CHEESE DISPENSER 0 C 14C* 1 WIRE SHELF FOR NACHO CHIP BAGS 0 C 15B 1 - ICE COOLER 0 C CONDIMENT UNITS 24Z* 1 APW WYOTT RTR-4 REFRIGERATED COUNTERTOP CONDIMENT UNIT 0 C 24X1* 1 PLASTIC PRODUC CC-13 SA CONDIMENT BIN: 2-TIEF, SINGLE -SIDED, HALF-SIZE, SUPPLIED BY CABINET VENDOR 0 C FOUNTAIN BEVERAGE DISPENSER / POST MIX EQUIPMENT T25B CORNELIUS 621057601 FLAVOR FUSION (4 HEAD - 16 FLAVORS) MIDNIGHT BLACK 0 C 25U* 2 MBS 10-1-3W-SF-MBS BAG -IN -BOX RACK: 4Hx3W PRE -FITTED w/ PUMPS, TUBING, FITTINGS, BAG CONNECTORS AND TOP SHELF 0 C 25V* 1 --- — 1 BULK LIQUID CO2 SUPPLY SYSTEM, 20" DIAMETER X61" HIGH, WT. 290 LBS. 0 0 25W.1* 1 McCANN'S E400397 McCann's BIG MAC CARBONATOR 0 C 25X* 2 MBS BAG -IN -BOX RACK: 4Hx1W PRE-FITTEDw/ PUMPS, TUBING, FITTINGS, BAG CONNECTORS AND TOP SHELF 0 C T25Y 1 SCOTSMAN C0830 FOUNTAIN CUBE ICE MAKER 1400 lb. (AIR COOLED - REMOTE) 0 C T25YA 1 SCOTSMAN ERC311 REMOTE CONDENSER FOR 1400lb. CHEWY ICE MACHINE 0 C DISPLAY (SALES FLOOR) FREEZERSK 42A* OPTION MASTER-BILT BLG-27HD SINGLE DOOR DISPLAY FREEZER, SELF-CONTAINED 0 C STORAGE (BACKROOM)FREEZERS k �` 44B* 1 MASTERBILT T-49F DOUBLE DOOR STORAGE FREEZER, SELF-CONTAINED 0 C 44BR 1 MASTERBILT T 49F-RC DOUBLE DOOR STORAGE FREEZER, REMOTE CONDENSOR O C CONVECTION OVENS w �k w= z w 49D TURBOCHEF TORNADO - CONVECTION/MICROWAVE PIZZA OVEN 0 C 49E* TURBOCHEF NGC TORNADO 2 - CONVECTION/MICROWAVE PIZZA OVEN 0 C EH3* FAN & HOOD GREENHECK --- MTC EXHAUST HOOD (48"X48") & FAN SYSTEM WITH 10" DUCTWORK AND SWITCH - STANDARD EXTERNAL BOTTOM OF FAN HGT = 1Y-0" WHERE POSSIBLE 0 C EH4* FAN & HOOD GREENHECK — GNG/MFN EXHAUST HOOD (42"X60") & FAN SYSTEM WITH 10" DUCTWORK AND SWITCH - STANDARD EXTERNAL BOTTOM OF FAN HGT = 10'- 0" WHERE POSSIBLE 0 C 58X EXISTING --- --- BAKERY CASE 0 C 58Y CSC WORLDWIDE CUSTOM PACKAGE PASTRY DISPLAY CASE - WISCONSIN 6' 0 C 58Y.1 CSC WORLDWIDE CUSTOM PACKAGE PASTRY DISPLAY CASE - WISCONSIN 4'-10" 0 C AS1* 1 M 80H*� 2 88E* 2 94` 1 CO. 1248* 1 (COMPANY — 21E 1 AMANA SIGNAGE AND GRAPHICS SCHEDULE �� SUPPLIED BY VENDOR/ INSTALLED BY CONTRACTOR BASE Vomela part # QUANTITY ITEM DESCRIPTION AND MODEL # 014-20-X)OC COFFEE S 57* 1 SPEEDWAY SINGLE SICCED HOT BEVERAGES MENU BOARD - 33" X 14' - WALL MOUNT OR COUNTER MINT. WILEGS S 6T 1 ADJUSTABLE LEGS FOR 33" x 14" HOT BEVFRAGES MENU BOARD FOR COUNTER MOUNTING HOT DOG SHADOW BOX HEADER - 2"'NICK x 33" WIDE x 48" LONG WITH "What's Gdllin'?" GRAPHIC PANEL, OVAL AND C 172 1 MENU BOARD - SUSPENDED I ICOOLER - WAYFINDERS S 99-811-328- 10 CUSSPEDAA - (99-811-328) - SSA WAYFINGER SLEEVES - 1 SLEEVE EA/COOLER DOOR POST 112 PER BOX S 99-811-329* 10 CUSSPEDAB - (99-811-329) - SSA WAYFINDER BRACKET- 1 BRACKET EA/COOLER DOOR POST / 12 PER BOX- SILVER 'FOUNTAIN C 170 1 FOUNTAIiI SHADOW BOX HEADER - 2" THICK x 33" WIDE x 96" LONG WITH OVAL AND MEN HOT SANDWICH/P ZAIGRAB-N-GO S 252 1 FRESH FROM THE OVEN SHADOW BOX - 2" THICK x 33" WIDE x 48" LONG - SUSPENDED S 200C* 1 VOrAELA SHROUD GRAPHICS - (USED ON PI7ZA WARMER ONLY) HATCO FLAV-R-FRESH S TAN TAN PANELS — TBD RESTROOM / PLUMBING EQUIPMENT 8"x 8" ADA SIGNS ADA SIGN- BLUE BACKGROUND WHITE LETTERS, 6" RAISED SYMBOLS, 5/8" RAISED LETTER RESISTANT SCREWS FROZEN CARBONATED BEVERAGE DISPENSER VIPER 4 FROZEN CARBONATED BEVERAGE FREEZER, 4-HEAD, TOP EXHAUST BAG ICE MERCHANDISERS LP-460AS ICE MERCHANDISER, OUTDOOR, LOW PROFILE ATMS --- ATM TERMINAL, CASH DISPENSING ONLY ANTI -FATIGUE MATS "ERGO -STANCE" WEARWELL ANTI -FATIGUE & SAFETY FLOOR MAT FOR HORSESHOE CHECKOUT COUNTERS #489 COMMON COOKING EQUIPMENT FOR CAFE AND GNG LD-10 MICROWAVE OVEN (GNG: HOT DOG ISLAND, MFG: COFFEE ISLAND) 0 0 Z 0 0 �c THEE :' *IS AND ALL PROPOSSD WORK AIRE SUBJECT TO ANY CORSECTICNS REQUIRED BY PIELD INSPECKIRS THAT f4AY BE NECISBARY IN Oi41 M TO COMPI-Y WITH ALL APPLICABLE CODES. CONTRACTOR COPY 0 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634,7000 T WDPARTNERS.COM K. • MAY 2 2 2015 o. m c 0 ca w 0 U mLO nD T 0 r IOL NUDo �o aNWlil Z H CV Q Z) Lo CD O J z Q IJ LIJ = (�j J _U) F- Q- Lu m STORE BLDG NO. 6485 VERSION OR AFE NO. SCALE DESIGN TEAM DATE DGNR. J. YOUST 05-22.2015 PM./DP. D. TIMMER 05.22-2015 RVR./DP. B. BUZARD 0S22.2015 ORWG. NO. EQ-2 WOMEN 3 ' 1 I \ 12 SA-1 (TYP.) 7 20 (E) WF-1 5 1 10 RP-1 29 (E)SS-2 314' -- 17 314' 18 112" HW \� INSTALL INSIDE o n --� - CABINET (E) WH 4 11 BF-2 T25Y 14 15 C ECKV6EAND B LAN AG VALVE (j AQUASTAT FOR RECIRC PUMP � STORAGE DUNKIN 30 (E) SS-3 I r ( `N1 i�jJl1 a lr STORAGE r _ ATTENDANT Em (ICEMAKER) DOMESTIC WATER PLUMBING PLAN ®� SCALE: 1 /4" = 1'-0" PLUMBING LEGEND: DOMESTIC COLD WATER (CW) « DOMESTIC HOT WATER (HW, HWR) �A � A - FILTERED WATER (LINE, "A") B � B - FILTERED WATER (LINE "B") TEMPERED WATER(TW) G NATURAL GAS PIPING - - - - - - - TRAP PRIMER TUBING (E) EXISTING (N) NEW (R) RELOCATED CONNECT TO EXISTING PRIOR TO ANY WORK FIELD VERIFY EXACT LOCATION OF WATER SERVICE PIPING UNDER THE FLOOR AND WATER EIRANCHES UNDER THE FLOOR. COORDINATE NEW TRENCH LOCATION WITH ELECTRICAL AND EXISTING UNDERFLOOR PIPING. DUAL CHECK BACK FLOW PREVENTER ISOLATION VALVE CARBONATOR PUMP WATER HAMMER ARRESTER HOT WATER RECIRCULATION PUMP 13 116 LT25E (DISPENSER) SALES AREA 11 - REFER TO ARCHITECTURAL DRAWINGS FOR EQUIPMENT SCHEDULE NOTES: REFER TO EQUIPMENT SCHEDULE FOR SPECIFICATIONS OF EQUIPMENT PROVIDED BY OWNER. .L INSIDE CABINET _ 13 16 80H BF-2�, WALK-IN CAVE gm, WALK-IN COOLER ffm WALK-IN FREEZER mmi. GENERAL NOTES: A. CONTRACTORS SHALL SUPPLY (6) COPIES OF SHOP DRAWINGS TO PROJECT MANAGER SO THAT QUALITY OF CONTRACTOR SUPPLIED EQUIPMENT, FIXTURES, APPLIANCES, AND MATERIALS CAN BE REVIEWED PRIOR TO INSTALLATION CONTRACTOR AND VENDOR PLUMBING vw DRAWINGS SHALL INCLUDE: 1. PLAN VIEW, SECTIONS, AND ELEVATIONS OF ADDITIONAL PLUMBING SYSTEMS, EQUIPMENT, FIXTURES, AND APPLIANCES. 2. APPLICABLE CODES FOR INSTALLATION. B. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, INSPECTIONS, LICENSES, AND FEES NECESSARY TO COMPLETE WORK PER CONSTRUCTION DOCUMENTS AND APPLICABLE CODES. CONTRACTOR SHALL REQUEST AND MAKE ARRANGEMENTS FOR NEW AND TEMPORARY UTILITY SERVICES PRIOR TO START OF CONSTRUCTION. C. SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT CONTRACTOR HAS FAMILIARIZED THEMSELVES WITH THE CONSTRUCTION DOCUMENTS, CONSTRUCTION SITE, AND IS PREPARED TO PROVIDE A COMPLETE INSTALLATION PER THESE CONSTRUCTION 7007 DISCOVERY BLVD DOCUMENTS, ALL APPLICABLE CONSTRUCTION CODES, AND MANUFACTURER'S RECOMMENDATIONS. WHERE CONDITIONS REQUIRE THAT DUBDN, off 43017 si4ss4.7oos T CHANGES BE MADE TO THE CONTRACT DOCUMENTS, AND THOSE CHANGES DO NOT ALTER THE SCOPE OR NATURE OF THE ORIGINAL WORK, CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT ADDITIONAL COST TO OWNER. WDPARTNERS.COM D. THE OWNER SHALL SUPPLY ONLY EQUIPMENT, FIXTURES, AND APPLIANCES SPECIFIED AS -OWNER SUPPLIED'. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL OWNER SUPPLIED EQUIPMENT, FIXTURES AND APPLIANCES, AND FOR PROVIDING AND INSTALLING ALL OTHER EQUIPMENT, FIXTURES, APPLIANCES AND MATERIALS NOT SUPPLIED AND INSTALLED BY VENDORS. ALL EQUIPMENT, FIXTURES, APPLIANCES, AND MATERIALS PROVIDED BY CONTRACTOR SHALL BE NEW, UNUSED, LISTED AND LABELED FOR USE. CONTRACTOR SHALL JJ��I P• BOLVq���i� INSTALL ALL EQUIPMENT, FIXTURES, AND APPLIANCES IN COMPLIANCE WITH LABELING OF LISTING AGENCY, MANUFACTURER'S INSTRUCTIONS, `�P�• GEN SE • 90'�i APPLICABLE CODES AND REGULATIONS, AND CONSTRUCTION DOCUMENTS. WHERE CONFLICT EXISTS, NOTIFY ENGINEER OF RECORD FOR ADJUDICATION. ZtpET�324 E. WATER SERVICE AND DISTRIBUTION PIPE, TUBE AND FITTINGS SHALL CONFORM TO NSF 61. ALLOWABLE WATER SERVICE MATERIALS ARE TYPE _ 'L' COPPER COIL PER ASTM B75. ALLOWABLE MATERIALS FOR UNDERGROUND DISTRIBUTION ARE TYPE W COPPER COIL PER ASTM B75. ONLY * IV CC FOR TRAP PRIMERS PEX PER ASTM F877 MAY BE USED UNDER GROUND. UNDERGROUND TUBING SHALL HAVE NO JOINTS. ALLOWABLE STRfi�� MATERIALS FOR ABOVE GROUND DISTRIBUTION ARE TYPE'M' STRAIGHT AND TYPE'L' COIL COPPER PER ASTM B75, PEX PER ASTM F877, AND y P • �� CPVC PLASTIC PER ASTM D2846. COPPER JOINTS SHALL BE MADE WITH LEAD-FREE SOLDER. �c •.F(O R F. SANITARY BELLOW-GROUND CONDENSATE DRAIN PIPING SHALL BETYPEDULE 40 PER ASTM D2665. ABOVE L' COPPER COIL WITHOUT JOINTS. GROUND CONDENSATE DRAIN PIPING '',,FSS' pl l P SHALL BE PVC ; ��`•` G. INSTALL ACCESSIBLE MANUAL SHUTOFF VALVE AND UNION ON EVERY FIXTURE, AND AT WATER SERVICE CONNECTIONS TO EQUIPMENT AND APPLIANCES. TAG ALL VALVES TO IDENTIFY EQUIPMENT SERVED. H. STERILIZE DOMESTIC WATER SYSTEM USING CHLORINE OR CHLORINE COMPOUND PER AWWA-C652 OR CS186. REPEAT DISINFECTION PROCESS UNTIL RESULTS ARE ACCEPTABLE TO THE PLUMBING INSPECTOR. MAY 2 2 2915 I. CONTRACTOR SHALL PERFORM IN -PLACE, FULL FUNCTIONAL TESTS OF ALL PLUMBING SYSTEMS, EQUIPMENT, FIXTURES AND APPLIANCES: AND THESE SYSTEMS SHALL BE MADE TO OPERATE PER MANUFACTURER'S SPECIFICATIONS PRIOR TO JOB COMPLETION. INSULATE ALL DOMESTIC HOT AND TEMPERED WATER LINES WITH 3/4" FLEXIBLE ELASTOMERIC INSULATION COMPLYING WITH ASTM C534, TYPE I OR EQUAL. J. INSULATE ALL ABOVE GROUND DOMESTIC COLD WATER LINES WITH 1/2" FLEXIBLE ELASTOMERIC INSULATION COMPLYING WITH ASTM C534, TYPE I OR EQUAL. a K. ABOVE GROUND COMPRESSED AIR PIPING SHALL BE TYPE 'L' COPPER, AND SHALL BE SOLDERED WHERE POSSIBLE. THREAD PIPE FOR DEVICE a) CONNECTIONS. APPLY PIPE SEALING COMPOUNDS TO MALE THREADS (2) THREADS BACK FROM END. ABOVE -GROUND HOSE SHALL BE EPDM c RUBBER OR PVC WITH NYLON REINFORCEMENT RATED FOR 200 PSI. o L. PROVIDE PIPING SUPPORT AND INSULATION ON ALL ACTIVE EXISTING WATER DISTRIBUTION PIPING AS NEEDED. M. IN THE INSTALLATION OR REMOVAL OF ANY PART OF A DRAINAGE SYSTEM, DEAD ENDS SHALL BE PROHIBITED. N U CONSTRUCTION KEY NOTES: ❑ a04 m 1. ALL PLUMBING UNDER LAVATORIES SHALL BE COVERED OR INSULATED WITH "TRAP WRAP" BY BROCAR-PRODUCTS, INC.. T»ALO 2. NOT USED. % 3 m O =bE 3. CONNECT TO APPROPRIATE EXISTING WATER PIPING (DOMESTIC WATER, HOT WATER, FILTERED WATER) THAT IS TO REMAIN. a nA o a`tnW W 4. EXISTING 20 GAL. RHEEM XE20PO6PU2OUO WATER HEATER TO REMAIN. 5. EXISTING WATER FILTER SYSTEM TO REMAIN. MAKE CONNECTIONS PER MANUFACTURER'S INSTRUCTIONS AND DETAIL 2ON SHEET P4. EXTEND FILTERED COLD WATER'A' AND'B' TO EQUIPMENT AS SHOWN 6. EXISTING THREE -COMPARTMENT SINK (SS-1) TO REMAIN. 7. EXISTING MOP SINK (SS-2) TO REMAIN. 8. EXISTING HAND SINK (SS-3) TO REMAIN.Q w� 9. NOT USED. gw �Q 10. EXISTING LAVATORY TO REMAIN. R �w a �m ma 11. EXISTING WATER CLOSET TO REMAIN.F °o a O 12. INSTALL WATER HAMMER ARRESTER ON WATER SUPPLY LINE. �� Ny z zo 13. PROVIDE AND INSTALL NSF APPROVED BACKFLOW PREVENTER AHEAD OF EQUIPMENT SHUTOFF VALVE. BEVERAGE DISPENSERS PROTECTED <w WITH INTEGRAL BACKFLOW PREVENTERS PER ASSE #1032 SHALL ALSO HAVE A BACKFLOW PREVENTER PROTECTING THE WATER SUPPLY o k CONNECTION, PER ASSE #1022. INSTALL A DISCHARGE VENT FROM BACKFLOW PREVENTER(S) PROTECTING CARBONATED BEVERAGE a PIPING/TUBING. DISCHARGE ABOVE FLOOR DRAIN. DO NOT INSTALL COPPER TUBE OR PIPE ON DOWNSTREAM SIDE OF THIS BACKFLOW LLw PREVENTER.¢ WX 14. PROVIDE AND INSTALL ASSE 1022 APPROVED DUAL CHECK BACK FLOW PREVENTER WITH ATMOSPHERIC VENT, IN FILTERED WATER LINE'B'. o ¢5 INSTALL VALVE AT ACCESSIBLE LOCATION AS SHOWN. DISCHARGE VENT PIPE INDIRECTLY INTO FLOOR DRAIN. w ao w 15. PROVIDE AND INSTALL FDA APPROVED NATURAL COLOR REINFORCED BRAIDED POLYETHYLENE TUBING (PREFERRED) OR 3/8" COPPER COIL (IF wo ow REQUIRED) TO ALLOW MOVEMENT OF BEVERAGE EQUIPMENT FOR CLEANING, zo so 16. INSTALL FILTERED COLD WATER W TO CARBONATOR PUMPS. BACKFLOW PREVENTER SHALL BE INSTALLED AHEAD OF REMOTE CARBONATOR. ' w REMOTE CARBONATORS SHALL BE INSTALLED WITHIN 8'-0" FROM BEVERAGE DISPENSERS. INSTALL SYRUP TUBING BETWEEN BAG-N-BOX AND Io. COLD/FROZEN BEVERAGE DISPENSERS. 17. INSTALL FILTERED COLD WATER'B' TO COFFEE MAKER(S), TEA DISPENSER(S), ICEMAKER(S), DRINKING WATER DISPENSER(S), AND MILKSHAKE o BLENDER. 18. INSTALL CARBONATED AND FILTERED WATER LINE `.A' FROM CARBONATOR PUMPS TO COLD CARBONATED BEVERAGE DISPENSERS.. 19. NOT USED. N THCE':,E PLA!,UB A1ND ALL PROPOSso L^ o l W `o Z)0) 20. NOT USED. ARE SUBJECT TO ANY CORRECTIC?J - 00 M REQUIRED BY PIE•LD NSPEC�Rs liij�'(' -I 21. NOT USED. &LAY BE NECCj6ASBT IN OtgL-" i C T LL CC7�tPi3°!�/IIu�/,•�fi_,Pnl �, Z Q W 22. NOT USED. (ir�r _9� ���E CCr V 23. NOT USED. �r J 24. NOT USED. uj cl) ,� C 25. NOT USED. C�N75 TRACTM. copy ® 0 0 26. NOT USED. �+ A fl ���II�' 27. NOT USED. 28. NOT USED. STORE OR 6485 29. PROVIDE RE -CIRCULATION PUMP AND CONNECT TO INLET LINE OF EXISTING WATER HEATER SEE DETAIL 6 ON P4. BLDG NO. VERSION 30. CONNECT NEW HOT WATER RETURN PIPING TO EXISTING HOT WATER SUPPLY PIPING SERVING EXISTING HAND SINK. CORDINATE WITH OTHER OR AFE NO. TRADES. SCALE: 04 DESIGN TEAM DATE DGNR. J. YOUST 04-27-2015 PM./DP. D. TIMMER 04.27.2015 RVR./DP. R. NAHHAS O4.27-2015 DRWG. NO. P1 I MEN LGT:i� HALL �- 1 I (TYP.) (E) FD i E)SAN Ii �.... Jp O�(E)` (TYP.) I � I L 7 (E) FD WOMENRi1Ti7 L -(E)SAN--T I f. I i _ (E)SS-3 STORAGE T25Y 18 16 I _ T256 18 16 i DUNKIN ff 1 �I �1'7_ (E)SS-3 01 SANITARY SYSTEM PLUMBING PLAN SCALE: 1/4" = V-0" PLUMBING LEGEND: EXISTING ABOVE GROUND SANITARY EXISTING UNDERGROUND SANITARY NEW ABOVE SLAB SANITARY WASTE BAN NEW BELOW SLAB SANITARY WASTE GW NEW BELOW SLAB GREASE WASTE --------------- NEW VENT PIPING -� D NEW CONDENSATE PIPING (E) EXISTING (N) NEW (R) RELOCATED CONNECT TO EXISTING PRIOR TO ANY WORK, FIELD VERIFY EXACT LOCATION AND INVERT OF ALL INCOMING SANITARY PIPING. COORDINATE NEW TFIENCH LOCATIONS WITH ELECTRICAL AND EXISTING UNDERFLOOR PIPING. 2 (E) FD l 31 FS-1 O SALES AREA 11 - REFER TO ARCHITECTURAL DRAWINGS FOR EQUIPMENT SCHEDULE NOTES: REFER TO EQUIPMENT SCHEDULE FOR SPECIFICATIONS OF EQUIPMENT PROVIDED BY OWNER, -u (E) SS-3 17 18 80H EVAP-2A r 21 EVAP-26 22 0 0 U w a w w' WALK-IN COOLER 20 I' ¢ IC i 27 LU IL J �1 1s l tt _ I � Q I- 3 u 'w' 0 w i WALK-IN FREEZER a ■ > w w GENERAL NOTES A. ALL ABOVE GROUND CONDENSATE LINES AND DRAINS SHALL BE TYPE M COPPER. B. ALL UNDERGROUND CONDENSATE LINES AND DRAINS SHALL BE TYPE L COPPER. C. ALL UNDERGROUND WASTE PIPING SHALL BE 4" SERVICE WEIGHT CAST IRON OR PVC WITH NEOPRENE PUSH GASKETS. D. ALL ABOVE GROUND WATER SUPPLY LINES SHALL BE TYPE L COPPER. E. ALL ABOVE GROUND CIWV PIPING SHALL BE METALLIC; TYPE M COPPER, OR CAST IRON WITH NO -HUB JOINTS. F. PVC FLOOR DRAINS ARE NOT PERMITTED. ALL MATERIALS SHALL BE METALLIC. G. PRIOR TO COMPLETION OF WORK, DRAIN ALL TANKS, GREASE INTERCEPTOR, AND ALL PLUMBING FIXTURES, EXAMINE ALL TRAPS, SUPPLIES, SHUTOFF VALVES, PIPING INSULATION AND CLEAN AND REMOVE ALL DEBRIS FROM ALL FIXTURES. FILL AND RETURN TO FULL SERVICE. REPORT TO THE CONSTRUCTION MANAGER ANY DAMAGE, DEFICIENCY IN OPERATION OR ANY CONDITION WHICH PREVENTS OPERATION OF ANY DEVICE, EQUIPMENT OR FIXTURE. REPLACE ALL DAMAGED COMPONENTS AND REPAIR AS DIRECTED BY CONSTRUCTION MANAGER DURING THE COURSE OF THE WORK. CONSTRUCTION KEY NOTES: ❑ 1. THOROUGHLY CLEAN EXISTING SANITARY. 2. VERIFY EXISTING SANITARY LINE INVERT ELEVATION AND ROUTING BEFORE ROUTING NEW SANITARY LINE. IF POSSIBLE ROUTE PIPING COMPLETELY UNDERNEATH SLAB STRUCTURAL STEEL AND CONNECT TO EXISTING SANITARY LINE. IF REQUIRED ROUTE PIPING TO PENETRATE EXISTING SLAB STRUCTURAL STEEL PER DETAILS SHOWN ON ARCHITECTURAL SHEETS (6/A5). INSTALL BUILDING DRAIN WITH PITCH OF 1/8" PER FOCI (1%). SEE DWV ISOMETRIC FOR SIZES. 3. NOT USED. 4. NOT USED. 5. CLEAN EXISTING MOP SINK TO LIKE NEW CONDITION. 6. CLEAN EXISTING THREE COMPARTMENT SINK TO LIKE NEW CONDITION. 7. CLEAN WATER CLOSET/URINAL TO LIKE NEW CONDITION. 8. CLEAN EXISTING LAVATORY TO LIKE NEW CONDITION. 9. CLEAN EXISTING HAND SINK TO LIKE NEW CONDITION. 10. NOT USED. 11, NOT USED. 12. NOT USED. 13. INSTALL FLOOR SINK WITH "P" TRAP. ELEVATE ABOVE FINISHED FLOOR PER OWNER REQUIREMENTS. REFER TO DETAIL 1 ON SHEET P4-. REUSE EXISTING FLOOR SINK IF IN A REUSABLE LOCATION AND SUFFICIENT SIZE. 14. NOT USED. 15. INSTALL FIXTURE VENT CONCEALED IN WALL. DO NOT OFFSET LESS THAN 6" ABOVE FLOOD LEVEL RIM OF FIXTURE SERVED. CONNECT TO NEAREST VENT THRU ROOF. 16. INSTALL 3/4" INDIRECT CONNECTED DRAIN AT A MINIMUM 1% PITCH FROM EQUIPMENT TO FLOOR DRAIN. MAINTAIN 1-1/2" AIR GAP AT FLOOR DRAIN. DO NOT MANIFOLD INDIRECT DRAINS. INSTALL TRAP AT EQUIPMENT CONNECTION WHERE DEVELOPED LENGTH OF DRAIN EXCEEDS 2 HORIZONTALLY OR 4' TOTAL. 17. INSTALL 1-1/4" INDIRECT CONNECTED DRAIN AT A MINIMUM 2% PITCH FROM EQUIPMENT TO FLOOR DRAIN. MAINTAIN 2-1/2" AIR GAP AT FLOOR DRAIN. CONTRACTOR SHALL CUT 1-1/4" HOLE IN FROZEN BEVERAGE DRAIN PAN AND ENSURE DRIP PROOF CONNECTION. 18. EXTEND BACKFLOW PREVENTER VENT LINE AND DISCHARGE OVER FLOOR DRAIN PER MANUFACTURER'S REQUIREMENTS. DO NOT MANIFOLD INDIRECT DRAINS. 19. EXISTING WALK-IN COOLERS TO BE REWORKED. MAINTAIN EXISTING CONDENSATE AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. 20. RECONNECT CONDENSATE LINE FROM RELOCATED EVAPORATOR AT POINT SHOWN. SLOPE CONDENSATE LINE AT 1/8"=V-0" TOWARDS EXISTING FLOOR SINK. ADJUST MOUNTING HEIGHT OF EXISTING DRAIN PIPING TO ALLOW MINIMUMSLOPE . 21. INSTALL 1" CONDENSATE DRAIN AT MINIMUM 1% PITCH FROM EVAPORATORS TO COOLER WALL PENETRATION. SECURE CONDENSATE DRAIN TO COOLER WALL 22. INSTALL PVC SLEEVE WHERE CONDENSATE LINE PENETRATES WALLS. COMPLETELY SEAL BOTH SIDES OF ANNULAR SPACE WITH EXPANDABLE FOAM INSULATION. EXTEND CONDENSATE DRAIN TO CONNECT TO EXISTING CONDENSATE DRAIN PIPING. 23. NOT USED. 24. NOT USED. 25. NOT USED. 26. NOT USED. 27. RELOCATE EXISTING EVAPORATOR TO LOCATION SHOWN, OR AS DIRECTED BY REFRIGERATION SYSTEM VENDOR'S REPRESENTATIVE. COORDINATE WITH OTHER TRADES. 28. MAKE CONNECTION TO EXISTING BUILDING SANITARY PIPING FROM THIS LOCATION TO EXISTING SANITARY MAIN. VERIFY EXISTING SANITARY LINE LOCATION AND INVERT BEFORE ROUTING NEW SANITARY PIPING. THEE PLANS AND ALL PROPOSaSO WORK ARE SUBJECT TO ANY CORRECTICNS REOUIRED BY MILD INSPEC70RS THAT MAY BE NECESSARY IN QWM TO COMPLY WITH ALL APPLICABLE CODES. CONTRACTOR COPY wd 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM %'o Ip' BC_L y,9����e �P� .... E N S �132A pE STA """s S I O N N�n I0% MAY It % 2015 a m 0 0 U 0 N e 0 U l6Lo no Aca mor a -CI N o a �a)uo a`tnww y Lu N ~ OMU) T J U) W of (j J Q _ F- U) cf) Z I CE STORE OR 648.5 BLDG NO. VERSION OR AFE NO. SCALE: DESIGN TEAM DATE DGNR. J. YOUST 04.27-2015 PM./DP. D. TIMMER 04-27-2015 RVR./DP. R. NAHHAS O4-27.2015 DRWG. NO. 12 CA U T 10 N° Seto, the taeperat. rlrtor dw hoc. pmv Wee hotter water, which increases eta nsk of scald mJvy O F as, ew , erbeN cure ha g emIaMtlrfwildae OO ad wM twg.twMasacqt O Fed vice Man hetlmq or sl wed m padr�met O ." omdiwePca vrdwmd �awbadwltado Yoa idawsua awemssve+has ndwtbd+Wie^e9e ®m nw mJUeMvp ofWF.4i&4"nv.h'-oww SCALD WARNING LABEL TO BE PROVIDED AT EACH MIXING VALVE AND FAUCET DISPENSING 140a WATER 5 SCALD WARNING LABEL NOT TO SCALE WATER FILTER "WF-1" FLOWC:-- ? 3/4" COLD WATER SUPPLY O O o FILTERED WATER FLOW FLOWC� TOP VIEW NO SCALE MANIFOLD (TYP 2) —\ 3/4" COLD WATER SUPPLY (BEHIND TAP "A") FLOW FILTER TAP "A" CARBONATOR PUMP(S) FROZEN BEVERAGES, (SIZE PER PLAN) — 34" CLEARANCE TO NEAREST OBSTRUCTION OR 60" A.F.F. MAY MOUNT ABOVE DOOR FILTER TAP'B' COFFEE MAKER(S), CAPPUCCINO DISPENSER(S), MILKSHAKE DISPENSER(S), ICE MAKER(S), ICE TEA DISPENSER(S), DRINKING WATER C� (SI;E PER PLAN) SERVICE VALVE (TYP) SERVICE UNION (FYP) SCALE INHIBITOR CARTRIDGE FILTER (TYP 2) FINISHED FLOOR 2 WATER FILTER DETAIL -FRONT VIEW NOT TO SCALE (E) HOT WATER DISTRIBUTION (E) WATER HEATER RECIRCULATION PUMP (RP-1) CHECKVALVE 12" (E)COLD WATER SUPPLY PROVIDE NEW T&P RELIEF VALVE. CONNECT VALVE OUTLET PIPING TO 6" ABOVE MOP SINK FLOOD RIM LEVEL. 3/4" FINISHED FLOOR 6 WATER HEATER DETAIL NOT TO SCALE 19LIE101:4 atell] .1 O 0af md 7007 DISCOVERY BLVD DUBLIN, OH 43017 LINE ---q TO EXISTING HAND SINK 614.634.7000 T IN STORAGE AREA I W DPARTNERS.COM INDIRECT WASTE FROM BEVERAGE EQUIPMENT (TYP) FLOWo SIOUX CHIEF MODEL #861-3PN 3" PVC FLOOR SINK WITH HALF OPEN SANITARY SEWER CAST NICKEL STRAINER AND RING AND ALUMINUM DOME BOTTOM PITCH AWAY STRAINER FROM FIXTURE TRAP 1 ISLAND SINK WITH AIR GAP NOT TO SCALE THEE FLANS AND ALL PROPOSGO Wovi ARE SUBJECT TO ANY CORAECTICNS REQUIRED BY PIELD INSPECXRS THAT f4AY BE NECI%AaY IN OADM TO COMPLY WITH ALL APPLICABLE CODES. CONTRACTOR COPY `,`�tttu udddfd��� p. BOt :w= ��'bFSSI ON P��.�`�• MAY 2 2 2015 r C. 0 C O V N G U M 04 (a r rca m 4a'rx M�0o dyc� aOwo m0.cc y a`fnWW N � rn O M W J T LL ® Q 0 Li U z ('3 J = U) U)ZD cm G H 0 J (D a STORE O BLDG NO.. 6485 LDG VERSION OR AFE NO. SCALE: 0 4 DESIGN TEAM DATE DGNR. J. YOUST 05-22-2015 PM./DP. D. TIMMER 05-22-2015 RVR./DP. R. NAHHAS 05-22-2015 17►FifLeaR� is, ❑ 13 110 CFM ar I i ❑ 13 110 CFM WOMEN ❑7 ❑ 100 CFM 200 CFM — -- 7 200 CFM STORAGE 200 CFM P I 7 900 CFM EVAP-2A 1EVAP-213 UTILITY ❑ 20❑ T Cu Cu WALK-IN 10 CAVE 3 . I-- 11.1.. .,., .....,,1, lii " nTMn un nao% inn ecnn ❑ JI I 300 CFM �� it III _1 7 [ f' ❑ �—�—— ❑ I -yl _ 3000❑FM� L 300CFM J ❑ CU ❑ 0 J ❑ " I � 1 I C. 300 CFM I � I i 18 1 20 RTU-1 4 1 I i 4 ❑ ..... 1 1 (ICEMAKER) I iJ C I 0 u 300 CFM MECHANICAL PLAN ® 1 SCALE: 1 /4" = MECHANICAL LEGEND I El 350 CFM 10 350 CFM i 9 6 300 CFM 12X16 RECTANGULAR DUCT �� TURNINGVANES (FIRST DIMENSION IS SIDE SHOWN) 12' 6 ROUND DUCT FLEXIBLE DUCT ® SUPPLY DIFFUSER WITH VOLUME FLOW RATE AND 300 CFM SECTORIZING BLADE INDICATORS MANUAL VOLUME DAMPER � BALANCE INDICATOR ® RETURN GRILLE # DUCTWORK CHANGE IN ELEVATION SO DUCT MOUNTED SMOKE DETECTOR RISE (R) DROP (D) F EXHAUST FAN WITH E 2'-X12' 12'X HORIZONTAL ECCENTRIC TRANSITION TAG FOR DESCRIPTION Fit N ELECTRIC MOTOR WITH FOB VERTICAL ECCENTRIC TRANSITION M_1 TAG FOR DESCRIPTION FLAT ON BOTTOM (FOB), FLAT ON TOP (FOT) 100 10 3460 CFM ❑ 300 CFM 300 CFM 14 I L E CU J 350 CFM ' 350 CFM' -I !. ------I -- i Q THERMOSTAT O REMOTE SENSOR AO SMOKE ALARM ANNUNCIATOR REMOTE TEMPERATURE SENSOR — GAS — NATURAL GAS PIPING —,� -- GATE VALVE — BALL VALVE --� F— CHECK VALVE — — — — NEW EQUIPMENT ON ROOF — EXISTING EQUIPMENT ON ROOF 15 w 16 a ❑ lal � Lu ICI I LL J WALK-IN COOLER gm WALK-IN COOLER — ii� a W_ 21 LD rl_15 GENERAL NOTES: A. CONTRACTORS SHALL SUPPLY (6) COPIES OF SHOP DRAWINGS TO PROJECT MANAGERS SO THAT QUALITY OF CONTRACTOR SUPPLIED EQUIPMENT, FIXTURES, APPLIANCES, AND MATERIALS CAN BE REVIEWED PRIOR TO INSTALLATION. CONTRACTOR AND VENDOR MECHANICAL DRAWINGS SHALL INCLUDE: 1. PLAN VIEW, SECTIONS, AND ELEVATIONS OF ADDITIONAL MECHANICAL SYSTEMS, EQUIPMENT, FIXTURES, AND APPLIANCES. 2. APPLICABLE CODES FOR INSTALLATION. B. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, INSPECTIONS, LICENSES, AND FEES NECESSARY TO COMPLETE WORK PER CONSTRUCTION DOCUMENTS AND APPLICABLE CODES, CONTRACTOR SHALL REQUEST AND MAKE ARRANGEMENTS FOR NEW AND TEMPORARY UTILITY SERVICES PRIOR TO START OF CONSTRUCTION. C. SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT CONTRACTOR HAS FAMILIARIZED HIMSELF WITH THE CONSTRUCTION DOCUMENTS, CONSTRUCTION SITE, AND IS PREPARED TO PROVIDE A COMPLETE INSTALLATION PER THESE CONSTRUCTION DOCUMENTS, ALL APPLICABLE CONSTRUCTION CODES, AND MANUFACTURER'S RECOMMENDATIONS. WHERE CONDITIONS REQUIRE THAT CHANGES BE MADE TO THE CONTRACT DOCUMENTS, AND THOSE CHANGES DO NOT ALTER THE SCOPE OR NATURE OF THE ORIGINAL WORK, CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT ADDITIONAL COST TO OWNER. D. THE OWNER SHALL SUPPLY ONLY EQUIPMENT, FIXTURES, AND APPLIANCES SPECIFIED AS'OWNER SUPPLIED'. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL OWNER SUPPLIED EQUIPMENT, FIXTURES AND APPLIANCES, AND FOR PROVIDING AND INSTALLING ALL OTHER EQUIPMENT, FIXTURES, APPLIANCES AND MATERIALS NOT SUPPLIED AND INSTALLED BY VENDORS. ALL EQUIPMENT, FIXTURES, APPLIANCES, AND MATERIALS PROVIDED BY CONTRACTOR SHALL BE NEW, UNUSED, LISTED AND LABELED FOR USE. CONTRACTOR SHALL INSTALL ALL EQUIPMENT, FIXTURES, AND APPLIANCES IN COMPLIANCE WITH LABELING OF LISTING AGENCY, MANUFACTURER'S INSTRUCTIONS, APPLICABLE CODES AND REGULATIONS, AND CONSTRUCTION DOCUMENTS. WHERE CONFLICT EXISTS, NOTIFY ENGINEER OF RECORD FOR ADJUDICATION. E. BALANCE UNIT FANS PER DESIGN STATIC PRESSURE DIFFERENTIALS, SPEEDS AND AMPERAGE DRAWS. SUBMIT AN AIR BALANCE REPORT TO PROJECT MANAGER. F. ALL DUCT SIZES ARE INSIDE DIMENSIONS. CONSTRUCT AND INSTALL DUCT SYSTEM PER'SMACNA' DUCT CONSTRUCTION STANDARDS. SEAL ALL TRANSVERSE AND LONGITUDINAL JOINTS USING ADHESIVES, GASKETS OR TAPE COMPATIBLE WITH DUCT CLASSIFICATION. PRESSURE SENSITIVE TAPE SHALL NOT BE USED AS A PRIMARY SEALANT. PROVIDE A SEAL AGAINST BOTH POSITIVE AND NEGATIVE PRESSURES. G. ALL AIR -HANDLING DUCT SHALL BE THERMALLY INSULATED TO MINIMUM R-6. RECTANGULAR DUCT MAY BE SHEET METAL OR 1" FIBERGLASS, CLASS 1 DUCT BOARD, LISTED PER UL 181. RCUND DUCT MAY BE SHEET METAL OR FLEXIBLE FIBERGLASS. FLEXIBLE DUCT SHALL NOT BE USED AS AN ELBOW. "ONLY NEW" FLEXIBLE DUCT SHALL NOT EXCEED 4' IN LENGTH. ALL DUCT SHALL BE INSTALLED PER'SMACNA' STANDARDS AND MANUFACTURER'S RECOMMENDATIONS. TURNING VANES SHALL BE PROVIDED IN ALL RECTANGULAR DUCT ELBOWS. H. RUNOUT DUCT SIZES SHALL BE SAME SIZE ROUND DUCT AS DIFFUSER NECK SIZE UNLESS INDICATED OTHERWISE. I. ALL FIELD INSTALLED ELECTRICAL WIRING SHALL BE STRANDED COPPER CONDUCTORS WITH 75 DEG C. WATER-RESISTANT INSULATION, AND BE INSTALLED PER THE LATEST EDITION OF NFPA 70. J. CONTRACTOR SHALL PERFORM IN -PLACE, FULL FUNCTIONAL TESTS OF ALL MECHANICAL SYSTEMS, EQUIPMENT, FIXTURES AND APPLIANCES: AND THESE MECHANICAL SYSTEMS SHALL BE MADE TO OPERATE PER MANUFACTURER'S SPECIFICATIONS PRIOR TO JOB COMPLETION. K. ALL ABANDONED DUCTWORK SHALL BE REMOVED FROM SITE. CONSTRUCTION KEY NOTES: 1. NOT USED. 2. NOT USED. 3. NOT USED. 4. EXISTING ROOFTOP UNIT TO REMAIN. REFER TO SCHEDULE ON SHEET M2 FOR UNIT INFORMATION. PROVIDE AND INSTALL MANUAL OUTSIDE AIR DAMPER AND REBALANCE TO CFM INDICATED IN BUILDING AIR BALANCE SCHEDULE ON DRAWING M2. 5. NOT USED. 6. EXISTING REMOTE TEMPERATURE SENSORS ON SALES AREA CEILING TO REMAIN. FIELD VERIFY EXACT LOCATION, 7. EXISTING SUPPLY AIR DIFFUSER TO REMAIN. REBALANCE TO CFM INDICATED. 8. NOT USED. 9. NOT USED. 10. EXISTING RETURN AIR GRILLE TO REMAIN. 11. NOT USED. 12. NOT USED. 13. EXISTING RESTROOM EXHAUST FAN TO REMAIN. 14. EXISTING CONDENSER TO REMAIN. 15. EXISTING EVAPORATOR TO REMAIN. 16. RELOCATE EXISTING EVAPORATOR. PURGE, MODIFY, AND RECHARGE REFRIGERANT LINES AS NECESSARY. 17. INSTALL VENDOR SUPPLIED EVAPORATOR IN CAVE PER MANUFACTURER'S REQUIREMENTS. I& INSTALL LINE-SETFROM AND 4 CONDUCTOR CONTROL WIRING OM [ROOF / PAD] MOUNTED CONDENSING UNIT TO UNIT COOLERS/ MERCHANDISING EQUIPMENT. DO UBLE OUBLE INSULATE AND PROTECT EXTERIOR LINE SET USING 2" FOAM WRAP AND SCHAO PVC CONDUIT TO [ROOF f WALL PENETRATION. [INSTALL LINE SET THROUGH CHEMICAL EMICAL CURB OR SIMILAR ROOF PENETRATION SEALING SYSTEM.] INSULATE BOTH LIQUID AND SUCTION LINES INSIDE BUILDING USING 1" FOAM WRAP. PROVIDE ADDITIONAL REFRIGERANT WHERE LENGTH OF LINE -SET EXCEEDS FACTORY CHARCONNECTIONS. GE CAPACITY. MAKE FINAL CONTRACTOR IS RESPONSIBLE FOR SEALING ALL [ROOF / BUILDING] PENETRATIONS FOR MECHANICAL EQUIPMENT WATERTIGHT, COORDINATE WITH OTHER TRADES. 19. INSTALL ROOF MOUNTED CONDENSING UNIT ON EQUIPMENT RAILS SPANNING STANDING ROOF SEAMS. CONDENSING UNIT FURNISHED BY OWNER. MAINTAIN MINIMUM REQUIRED CLEARANCES: 3'-0" TO PARAPET WALLS, AND 2'-0" TO ADJACENT UNITS. 20. INSTALL NEW ROOF MOUNTED EQUIPMENT TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA MECHANICAL CODE SECTION 301.12 REGARDING WIND RESISTANCE. 21. MODIFY EXISTING WALK-IN FREEZER TO COOLER. FIELD VERIFY. COORDINATE WITH OTHER TRADES 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000T WDPARTNERS.COM BO(yq��.,4 .CENSE eC ' pE71324Lli '• OF I O N z O MAY 2 2 2015 a d 0 r O 3 e N C O U bA (DC) m @'(D 2 a�y0 vy�= m �vacs a`tl1WW nQ y3 =w o z ow w ZoZo 60 3w w3a ww w� Oy w w a a� O wx x� �3 ow w zU a0 QQ yw ❑ s� FQ O = N H Lo J Q co U r-i Z } Li = J =� LCLJ DO V) C = F- THESE PLANS AND ALL PROPOSM VIORK 00 CCD 0- D ARE SUBJECT TO ANY COWSCTICNS REQUIRED BY FIELD INSPEC PDRS THAT Gi4'AY BE NECENANY IN OIRLEM TO COMPLY IVITH ALL APPLICABLE CODES. " BLDGNOR 6465 VERSION OR AFE NO. SCALE: 0 4 DESIGN TEAM DATE CONTRACTt�R ODP. COPY PMN D.TMMER 05-22.2015 RVR./DP. R..NAHHAS 05.22-2015 DRWG. NO. M1 WALK-IN CAVE RFFRIGFRATION EQUIPMENT SCHEDULE MANUFACTURER/ CAPACITY TAG MODEL# DESCRIPTION (BTUH) VOLTS HP CU-2 RUSSELL WALK-IN CAVE CONDENSING UNIT; 253 LBS 24690 230 1 RLH301M44-D EVAP-2 (A,B) RUSSELL MEDIUM -TEMP LOW PROFILE UNIT EVAPORATOR WITH AIR DEFROST TIMER; 24500 115 1 AA56-245B-AE 180 LBS BRANCH DUCT L=W/4 (4" MIN.) RECTANGULAR 1" MIN. ON TOP AND BOTTOM MAIN DUCT W BALANCING DAMPER WHERE INDICATED ON THE DWG., MINIMUM OF (1) DUCT DIA. FROM MAIN DUCT. RECTANGULAR TO ROUND TAKEOFF ROUND DUCT 1 ROUND BRANCH CONNECTION DETAIL SCALE: NO SCALE THERMALLY INSULATED RECTANGULAR MAIN DUCT. MANUAL VOLUME DAMPER JOINTS SHALL BE CONNECTED USING MIN. 4"SLEEVE AND DRAW BAND. SEAL AGAINST POSITIVE AND NEGATIVE PRESSURES USING APPROVED SEALANT. PRESSURE SENSITIVE TAPE SHALL NOT BE PRIMARY SEAL. R-6 INSULATION ON ALL DUCT. SHEET METAL ROUND DUCT FABRICATED PER "SMACNA"STANDARDS SHEET METAL ELBOW. PROVIDE AND INSTALL TRANSITION IF REQUIRED. FLEXIBLE DUCT SHALL NOT BE USED AS ELBOW. CEILING 2 FLEXIBLE SUPPLY DUCT DETAIL SCALE: NO SCALE CONDENSING UNIT SCHEDULE(PACKAGED UNIT DIMENSIONS REFRIGERANT HEIGHT WIDTH DEPTH TYPE CHARGE (LBS) TAG EQUIPMENT MAKE WEIGHT N') NOTES CU-1 ICEMAKER (T24Y.4) SCOTSMAN 29.125 34 38.47 95 R-404A A,B,C ERC311-1 CU-2 WALK-IN CAVE RUSSELL 28.25 39.75 20.25 253 R-404A A,B,C CONDENSING UNIT RLH301M44•D DOUBLE DOOR FREEZER A,B,C CU-3 ITEM #44BR NOTES: A. CONTRACTOR IS RESPONSIBLE FOR ALL ROOF AND WALL PENETRATIONS (INCLUDING SLEEVES) AND SETTING OF THE OWNER AND VENDOR SUPPLIED REFRIGERATION AND HVAC EQUIPMENT. B. CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING REFRIGERATION LINES (IF NEEDED) AND THE START-UP OF THE EQUIPMENT. C. INFORMATION CONTAINED ON THIS SCHEDULE IS FOR INFORMATION REGARDING A SPECIFIC MANUFACTURER'S PRODUCT DATA. CONTRACTOR SHALL COORDINATE WITH ALL TRADES REGARDING ANY EQUIPMENT SUPPLIED BY ALTERNATIVE MANUFACTURERS FOR DIFFERENCES IN ANY DATA FROM THAT MENTIONED WITHIN SCHEDULE. MECHANICAL EQUIPMENT SCHEDULE MARK MAKE MODEL DESCRIPTION FAN RPM CFM ESP, MG AMPS POWER (HP) SONES DIMENSIONS (LxWxD) WEIGHT (E) RTU-1 TRANE EXISTING 12.5 TON UNIT 5000 TCD151C30OBB (E) EF-1 RESTROOM EXHAUST EXISTING FAN CEILING MOUNTED 110 (E) EF-2 RESTROOM EXHAUST EXISTING FAN CEILING MOUNTED 110 Ll I VENTILATION RATE SCHEDULE Based upon 2010 Florida Building Code-MechanIcaI(Table 403.3) 0 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM qR �p el j 324 :cC= P o MAY 2 2 2015 F1 a m c 0 Y 7 N c U mLO VD �c0 mf6d= a •3p 41� a a+'un o �a4AWW y �w eQ io - pQ w jo w ww ma Qm u •w F LL ?Q 0O 2z yW y z0 QU aw ok w3w a ywm 0, I� ¢W w uw O a0 wx > >on xti w o3 ¢ W 0. Zo La I¢ 0 Room Area Area CIA Rate Default Occupancy Occupancy People CIA Rate Total OA Room Name Classification (sq.ft.) (cfm/sq.ft.) (#/1000sq.ft.) (#) (cfm/person) (cfm) Sales Area Sales 1132 0.12 15 25 7.5 323 Attendant Area Sales 279 0.12 15 3 7.5 56 PIPE INSULATION Storage Area Shipping/Receiving 181 0.12 - - - 22 INSULATED REFRIGERATION Manager's Office Office Spaces 206 0.06 5 1 5 17 W PIPE STAINLESS STEEL BAND POSITIONED 114•INCH FROM Walk-in Cave 150 - - J O M STAINLESS STEEL BAND TOP OF THE STACK FLASHING 0.1 14 Hall Space 80 Q J T LL Walk-in Cooler/Equip. 331 W DURO-LAST PREFABRICATED VENT STACK FLASHING Men* UJI (lfixtures) Restroom 53 U LLJ = Women* M J MINIMUM 5, (lfixtures) Restroom 51 :E ~ Total (square feet) 2463 Required 432 Design 440 Air Balance Schedule = C NOTES: 1. MEMBRANE ATTACHMENT AROUND THE PENETRATION WILL BE THE SAME AS THE DECK MEMBRANE, MAX. 1 8-INCHES ON CENTER, AND A MINIMUM OF ONE PLATE/FASTENER PER FLASHING. 2. FILL RESULTING VERTICAL AND HORIZONTAL GAPS WITH A URETHANE FOAM AND TAPE CLOSED. 3 ROOF PENETRATION - INSULATED REFRIGERANT PIPE SCALE: NO SCALE Tag Outside Air(cfm) ReturnAir(cfm) SupplyAir(cfm) ExhaustAir(cfm) Pressure (cf m) %Outside Air (E)RTU-1 440 4560 5000 - 440 (E)EF-l* - - - 110 -110 (E)EF-2* 110 -110 Total: 220 220 *Minimum Exhaust air required by code is 70cfm/fixture. THESE PLANS AND ALL PROPOSSO WORK ARE SUBJECT TO ANY CORRECTICPIS REQUIRED BY FIELD NSPEC?ORS THAT UAY BE NECINASlY IN OROM TO COMPLY WITH ALL APPLICABLE CODES, CONTRACTOR COPY STORE O BLDG NOR 6485 1 VERSION OR AFE NO. SCALE: 0 4 DESIGN TEAM DATE DGNR. J. YOUST 05.22-2015 PM./DP. D. TIMMER 05.22-2015 RVR./DP. R. NAHHAS 05-22.2015 DRWG. NO. M2 Ir /y r EXISTING PANELS m^ 'MDP', 'A', 'B', r, 000 3 EXISTING EXISTING METER & CT CABINET. A-16 A-3 5 A-8 10 A-21,23 A-17,19 T25S T25Y 25Y 807H 80H _ T C-12 C-30 WP 901, 901, WP WP Wp WP Wp EVAP-2A EVAP-2B A-1 A-1 (TIE) (TIE) B-37 B-39 I A-20,22,24 013 I - N r CU 2 I I 303 22 _ LT J NN .� L__;,_ J 3012 - 8 A-13,15 I� (TYP) (TYP) - F C-41 F8_8_El 188E POWER PLAN 0 l SCALE: 1 /4" = 1'-0" ELECTRICAL LEGEND: El 4" DEEP ROUND STEEL ADJUSTABLE FLOOR BOX W/1/2", 3/4"AND 1 HUBBELL #B252 7 HUBBELL #S3725 COVER FOR SIMPLEX RECEPTACLE e- SIMPLEX RECEPTACLE, COMPACT, SPECIFICATION GRADE a GFCI RECEPTACLE, COMMERCIAL SPECIFICATION GRADE HUBBELL #S3925 COVER FOR DUPLEX RECEPACLE 15A, 125V NEMA 5-15R, IVORY: 20A, 120V NEMA 5-20R, IVORY: HUBBELL #HBL-52511 HUBBELL #GFR-53521A HUBBELL #S7 STAINLESS STEEL COVER PLATE HUBBELL #S26 STAINLESS STEEL COVER PLATE r__�9 DISTRIBUTION PANELBOARD WP-HUBBELL #HBL-7423WO THERMOPLASTIC WEATHERPROOF COVER OPEN WP-HUBBELL #WP826MP POLYCARBONATE WEATHERPROOF IN -USE VERTICAL COVER L SIMPLEX TWIST -LOCK RECEPTACLE WP-HUBBELL #WP826MHP POLYCARBONATE WEATHERPROOF IN -USE HORIZONTAL COVER ��LL3,,R DISCONNECT SWITCH 15A, 125V, 1 HP NEMA L5-15R, BLACK: HUBBELL #S7 DOUBLE DUPLEX ISOLATED -GROUND RECEPTACLE 1--13013 F -FUSIBLE N - NON -FUSIBLE STAINLESS HUBBELL #S7 STAINLESS STEEL COVER PLATE 20A, 125V, NEMA 5-20R, WHITE 3R - NEMA RATING WP-HUBBELL #HBL-7423WO THERMOPLASTIC WEATHERPROOF COVER OPEN 30/3 -AMP RATING/PHASE DUPLEX RECEPTACLE, HEAVY-DUTY, COMMERCIAL SPECIFICATION GRADE �G CEILING MOUNTED, DUPLEX RECEPTACLE, COMMERCIAL SPECIFICATION GRADE 20A, 125V NEMA 5-20R, WHITE: MOTOR HUBBELL #CR-5362W HUBBELL #S8 STAINLESS STEEL COVER PLATE SPECIAL-PURPOSE RECEPTACLE OUTLET. REFER TO MECHANICAL OR VVJP-HUBBELL #WP826MP POLYCARBONATE WEATHERPROOF IN -USE VERTICAL COVER COMMERCIAL KITCHEN EQUIPMENT SCHEDULE FOR NEMA © MAGNETIC CONTACTOR WP-HUBBELL #WP826MHP POLYCARBONATE WEATHERPROOF IN -USE HORIZONTAL COVER CONFIGURATIONS. RECEPTACLES SHALL BE MANUFACTURED BY DUPLEX ISOLATED -GROUND RECEPTACLE, SPECIFICATION GFIADE BRYANT OR EQUAL. SINGLE -POLE HEAVY-DUTY, COMMERCIAL SPEC GRADE TOGGLE SWITCH Ed20A, VARIABLE FREQUENCY DRIVE 125V NEMA 5-20R, ORANGE: HUBBELL NEMA 62W 20A, 120-277V, 1HP RATING, WHITE: HUBBELL #S8 STAINLESS STEEL COVER PLATE HUBBELL # W STAINLESS STEEL COVER PLATE HUBBELL #Sl S1 STAINLESS C SECURITY CAMERA WP-HUBBELL #HBL-1795 WEATHERPROOF COVER PLATE CCTV CCTV COAXIAL CABLE AND POWER OUTLET Q POWER KEYNOTES: 1. EXISTING SERVICE EQUIPMENT. COORDINATE ALL NEW WORK WITH 18. NOT USED. GENERAL CONTRACTOR. SEE ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULES FOR DETAILS. 19. FRACTIONAL HP HOT WATER RECIRCULATION PUMP. INSTALL HP RATED TOGGLE SWITCH. COORDINATE WITH PLUMBING CONTRACTOR AND G.C. IN 2. PROVIDE PLACARD TO LABEL EACH CIRCUIT BREAKER IN PANEL MDP AS FIELD. SERVICE DISCONNECT. 20. INSTALL RECEPTACLE WITH WEATHERPROOF WHILE IN USE COVER FOR 3. CORE DRILL OPENING IN ELECTRIC ROOM. FISH CIRCUITS IN WATER TIGHT NEW ICE MERCHANDISER. NOTE THAT THE EXISTING RECEPTACLE ON THIS FLEXIBLE CONDUIT UNDER FLOOR STRUCTURE TO EQUIPMENT LOCATION. EXTERIOR WALL IS FOR THE EXISTING ICE MERCHANDISER. 4. NOT USED. 21. NOT USED. 5. NOT USED. 22. NEW CONDENSING UNIT. REFER TO MECHANICAL EQUIPMENT SCHEDULE FOR CIRCUIT AND DISCONNECT SPECIFICATIONS. INSTALL PER 6. NOT USED. MANUFACTURER'S RECOMMENDATIONS. COORDINATE EXTERIOR/ROOF PENETRATIONS WITH THE MECHANICAL CONTRACTOR'S REFRIGERANT 7. NOT USED. LINE -SET. SEAL CONDUIT TO PREVENT CONDENSATION. INSTALL LIQUID TIGHT FLEXIBLE METAL CONDUIT WITH LISTED CONNECTORS BETWEEN 8. NEW WALK-IN CAVE DOOR LIGHTS AND DOOR HEATERS. INSTALL DOOR DISCONNECT AND EQUIPMENT. HEATER CONTROLLER. SEAL CONDUIT AT WALL OPENINGS. 9. NOT USED. 23. ATM RELOCATION MAY ALREADY BE COMPLETED BY OTHERS BEFORE REMODEL. VERIFY AT BID WALK. 10. INSTALL CLASS W GROUND -FAULT CIRCUIT INTERRUPTION CIRCUIT 24. INSTALL CIGARETTE FLEX FRAME OUTLETS HORIZONTALLY AT 88" AFF. BREAKER. WIRE DOWNSTREAM DEVICES AS SHOWN. LABEL EACH DEVICE GFCI PROTECTED'. GFCI RECEPTACLES PER LEGEND MAY ONLY BE USED 25. E.C. TO COORDINATE COOLER SIZE REDUCTION REQUIREMENTS AT SITE. IN PLACE OF CIRCUIT BREAKERS WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION. 26. PROVIDE FLOOR BOX FLUSH WITH FINISHED FLOOR. 11. PROVIDE RECEPTACLE OUTLET BELOW COUNTER WITHIN REACH OF 27. PROVIDE CONTROL WIRING BETWEEN OUT DOOR CONDENSING UNIT AND INTEGRAL CORD AND PLUG. INDOOR EVAPORATING UNIT(S) PER MANUFACTURER'S REQUIREMENTS. CONTROL WIRING TO BE INSTALLED ALONGSIDE OF LINESET. 12. PROVIDE RECEPTACLE OUTLET ABOVE COUNTER WITHIN REACH OF INTEGRAL CORD AND PLUG. 28. COORDINATE EXISTING FREEZER TO COOLER CONVERSION AT SITE. 13. ELECTRICAL SERVICES FED IN CONDUIT(S) UNDER SLAB FOR THESE 29. REMOTE CONDENSING UNIT CU-1A/CU-1 B POWERED BY RESPECTIVE ICE LOCATIONS UTILIZING SLAB CUTS AS SHOWN ON ARCHITECTURAL MAKER. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. DRAWINGS, ADDITIONAL SLAB CUTS SHALL BE KEPT TO A MINIMUM AND COORDINATE EXTERIOR/ROOF PENETRATIONS WITH THE MECHANICAL ONLY WHERE NECESSARY. COORDINATE WITH GENERAL CONTRACTOR CONTRACTOR'S REFRIGERANT LINE -SET. SEAL CONDUIT TO PREVENT AND PLUMBING CONTRACTOR. CONDENSATION. INSTALL LIQUID TIGHT FLEXIBLE METAL CONDUIT WITH LISTED CONNECTORS BETWEEN DISCONNECT AND EQUIPMENT. 14. NOT USED. 30. REMOTE CONDENSING UNIT CU-3 POWERED BY FREEZER, EQ# 44BR. 15. NOT USED, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE EXTERIOR/ROOF PENETRATIONS WITH THE MECHANICAL CONTRACTOR'S 16. NOT USED. REFRIGERANT LINE -SET. SEAL CONDUIT TO PREVENT CONDENSATION. INSTALL LIQUID TIGHT FLEXIBLE METAL CONDUIT WITH LISTED 17. NOT USED. CONNECTORS BETWEEN DISCONNECT AND EQUIPMENT. GENERAL POWER NOTES: A. THESE DRAWINGS MAY NOT SHOW ALL REQUIREMENTS NECESSARY FOR COMPLETE EQUIPMENT INSTALLATION. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH ALL MANUFACTURER'S INSTALLATION REQUIREMENTS AND TO PROVIDE A COMPLETE FUNCTIONAL SYSTEM. B. RECEPTACLE LOCATIONS SHOWN ON PLAN ARE APPROXIMATE. VERIFY EXACT LOCATIONS WITHIN CABINETRY AND TO FIXED EQUIPMENT PRIOR TO ROUGH -IN. ATTENDANT COUNTER RECEPTACLES SHALL BE MOUNTED WITHIN THE CABINETRY, UNLESS OTHERWISE NOTED. C. VERIFY AND COORDINATE EXACT LOCATIONS FOR CONDUIT STUB -UPS IN WALLS AND TO EQUIPMENT PRIOR TO ROUGH -IN. D. ELECTRICAL CONTRACTOR TO VERIFY THAT FINAL TOTAL CONNECTED LOAD OF ELECTRICAL PANELS DO NOT EXCEED PANEL RATING. REDISTRIBUTE LOAD TO PANELS WITH LESS CONNECTED LOAD IF NECESSARY. E. ALL MOUNTING HEIGHTS SHOWN ARE REFERENCED ABOVE FINISHED FLOOR. UNLESS OTHERWISE NOTED. F. ALL CONDUIT AND WIRING NOT USED IN EXISTING OR NEW CIRCUITS SHALL BE REMOVED BACK TO PANELS. G. EXTEND OR TRUNCATE EXISTING WIRING WHERE NECESSARY FOR CIRCUITS LABELED AS EXISTING. H. ALL SWITCH AND RECEPTACLE DEVICES SHALL BE WHITE IN COLOR. ALL DEVICE COVER PLATES SHALL BE WHITE PLASTIC, UNLESS OTHERWISE NOTED. I. OVERHEAD CONDUITS WITHIN THE BUILDING SHALL BE EMT OR TYPE MC CABLE WITH (1)#12 EQUIPMENT GROUND. ALL UNDERGROUND CONDUITS SHALL BE GALVANIZED RIGID STEEL (GRS) OR SCHEDULE 40 PVC, UNLESS OTHERWISE NOTED. J. INSTALL A SEPARATE PROPERLY SIZED GROUNDED CONDUCTOR (NEUTRAL) FOR EVERY CIRCUIT REQUIRING ONE. THE GROUNDED CONDUCTOR SHALL NOT BE WIRED TO THE EQUIPMENT GROUND BUS IN THE PANELBOARDS. INSTALL A SEPARATE GROUND BAR IF NECESSARY. K. INSTALL A PROPERLY SIZED GROUND FOR EVERY CIRCUIT. CONDUIT SHALL NOT BE USED AS THE SOLE EQUIPMENT GROUND BUT MAY BE USED AS A PARALLEL PATH. BOND EQUIPMENT GROUNDS AT ALL JUNCTION BOXES. THE EQUIPMENT GROUND SHALL NOT BE WIRED TO THE GROUNDED CONDUCTOR BUS. INSTALL A SEPARATE GROUND BAR IF NECESSARY. L. ALL WIRING SHALL BE INSULATED COPPER. RATED 600 VOLTS AND NO SMALLER THAN #12 AWG. INSULATED THHN OR THWN UNLESS OTHERWISE NOTED. M. WIRING FOR ISOLATED GROUND TYPE RECEPTACLE CIRCUITS SHALL BE (2)#12, (1)#12 EQUIPMENT GROUND, AND (1)#12 ISOLATED GROUND. ISOLATED GROUNDS SHALL BE INSULATED AND INSTALLED CONTINUOUS FROM THE SERVICE GROUND BUS TO EQUIPMENT WITH NO OTHER CONNECTIONS BETWEEN. N. SOME CIRCUITS MAY NOT BE REQUIRED OR SOME MAY HAVE TO BE ADDED. ALL REVISIONS MUST BE NOTED ON THE "AS BUILT" PRINTS. ALL PANELS AND CIRCUIT BREAKERS MUST BE LABELED. O. CONDUIT AND WIRE SIZES SHOWN IN PANEL SCHEDULES ARE MINIMUMS. CONTRACTOR SHALL INCREASE SIZES (DUE TO VOLTAGE DROP, QUANTITY OF CURRENT CARRYING CONDUCTORS, ETC.) AND ARRANGE CONDUIT ENTRY INTO WIREWAY AS REQUIRED BY NATIONAL ELECTRIC CODE. P. MOUNT ALL RECEPTACLES WITHIN REACH OF ASSOCIATED EQUIPMENT CORD & PLUG. Q. ALL POS TERMINALS, DISPENSERS, VEEDER ROOT D-BOX, TIGER AND OTHER FUEL EQUIPMENT MUST BE ON THE SAME PHASE. MTv CCTV MONITOR OUTLET 17 TELEPHONE OUTLET W/CONDUIT & PULLSTRING V TELEPHONE/DATA OUTLET W/CONDUIT & PULLSTRING ♦ DATA OUTLET W/CONDUIT & PULLSTRING 'LOW VOLTAGE WIRING BY OWNER OT THERMOSTAT E E - ELECTRIC L - LINE VOLTAGE LV- LOW VOLTAGE PB PUSHBUTTON ES EMERGENCY STOP PUSHBUTTON Fx-xXI EQUIPMENT NUMBER %\ ��� PHASE CONDUCTORS) \\�`—GROUNDED CONDUCTOR = GROUNDING CONDUCTOR ISOLATED GROUND DEMOLITION NOTES: 1. SEE DEMOLITION PLAN D1 FOR EXTENT OF DEMOLITION. 2. LABEL ALL CIRCUITS MADE SPARE AS "SPARE" ON UPDATED PANEL DIRECTORY. THE;"c PLAJNS AND ALL PROPOSSD Wo1 r, ARE SUBJECT TO ANY COWECTICNS REQUIRED BY FIELD NSP&CKIRS THAT UTAY BE NECI!%ASlY IN Of4M TO COMPLY WITH ALL APPLICABLE CODES. fi 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM r :X STATE OF *4u t �C `Q% MAY 2 2015 O i m 0 C 0 V 7 N 0 U clj ULO rca m@`yx 0 Boy= �ad"o co% aNCL WW 0 z 0 w = N H- Lo z O M Q J J r Ll_ Q L,; LLj C7 J I 00 CD a STORE OR BLDG NO. 648.5 VERSION OR AFE NO. SCALE: DESIGN TEAM DATE DGNR. J. YOUST 05.22-2015 PM./DP. D. TIMMER 05-22-2015 RVR./DP. G. HOLMAN 05-22-2015 DRWG. NO. E1 n LIGHTING PLAN SCALE: 1/4" = 1'-0° LIGHT FIXTURE SCHEDULE SYMBOL QTY WATTS MANUFAC. CATALOG # VOLT. LAMP TYPE REMARKS I 3 70 CREE PKG-EDG-40-DM-04-D-UL-WH- 120 'CREE' LED 40 DEGREE DISTRIBUTION, LED FIXTURE, ENCLOSED AND GASKETED WITH ELECTRONIC s7 525-40K BALLAST. LISTED FOR WET LOCATIONS. EX1 INTEGRAL LED (2) COMBINATION EXIT/EMERGENCY LIGHT WITH 90 MINUTE EMERGENCY BAT?ERY WITH 'Y` 1 10 COOPER LPXH70RWHDHNC 120 INTEGRAL INCANDESCENT REMOTE HEAD CAPACITY. LISTED FOR DAMP LOCATIONS. NICKEL -CADMIUM BATTERY TO ALLOW LOW -TEMP OPERATION.. WHITE HOUSING WITH 6" RED LED LETTERING. EX2 INTEGRAL LED (2) COMBINATION EXIT/EMERGENCY LIGHT WITH 90 MINUTE EMERGENCY BATTERY WITH 2 10 COOPER LPXH70RWHDH 120 INTEGRAL INCANDESCENT REMOTE HEAD CAPACITY. LISTED FOR DAMP LOCATIONS. WHITE HOUSING WITH 6" RED LED LETTERING. EDI 2 10 COOPER. 6X7DWWH 6 (2) SEALED BEAM INCANDESCENT EXIT DISCHARGE SPOT LIGHT. LISTED FOR WET LOCATIONS. NOTE: LIGHTING FIXTURES ON THIS SCHEDULE SHALL BE PROVIDED PY CONTRACTORS. (E) = EXISTING TO REMAIN, SEE GENERAL NOTE K. (R) = RELOCATED. REFER TO SHEET A2 SEE GENERAL. NOTE K: GENERAL LIGHTING NOTES: A. THESE DRAWINGS MAY NOT SHOW ALL REQUIREMENTS NECESSARY FOR COMPLETE EQUIPMENT INSTALLATION. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH ALL MANUFACTURER'S INSTALLATION REQUIREMENTS. AND TO PROVIDE A COMPLETE FUNCTIONAL SYSTEM. B. EXTEND OR TRUNCATE EXISTING WIRING WHERE NECESSARY FOR CIRCUITS LABELED AS EXISTING. C. ALL CONDUIT AND WIRING NOT USED IN NEW OR EXISTING CIRCUITS SHALL BE REMOVED BACK TO PANELS D. ALL SWITCH AND RECEPTACLE DEVICES SHALL BE WHITE IN COLOR. ALL DEVICE COVER PLATES SHALL BE WHITE PLASTIC UNLESS OTHERWISE NOTED. E. OVERHEAD CONDUITS WITHIN THE BUILDING SHALL BE EMT OR TYPE MC CABLE WITH (1) #12 EQUIPMENT GROUND. ALL UNDERGROUND CONDUITS SHALL BE GALVANIZED RIGID STEEL (GRS) OR SCHEDULE 40 PVC UNLESS OTHERWISE NOTED. F. INSTALL A SEPARATE PROPERLY SIZED GROUNDED CONDUCTOR (NEUTRAL) FOR EVERY CIRCUIT REQUIRING ONE. THE GROUNDED CONDUCTOR SHALL NOT BE WIRED TO THE EQUIPMENT GROUND BUS IN THE PANELBOARDS. INSTALL A SEPARATE GROUND BAR IF NECESSARY, G. INSTALL A PROPERLY SIZED GROUND FOR EVERY CIRCUIT. CONDUIT SHALL NOT BE USED AS THE SOLE EQUIPMENT GROUND BUT MAY BE USED AS A PARALLEL PATH. BOND EQUIPMENT GROUNDS AT ALL JUNCTION BOXES. THE EQUIPMENT GROUND SHALL NOT BE WIRED TO THE GROUNDED CONDUCTOR BUS. INSTALL A SEPARATE GROUND BAR IF NECESSARY. H. ALL WIRING SHALL BE INSULATED COPPER. RATED 600 VOLTS, AND NO SMALLER THAN #12 AWG. INSULATED THHN OR THWN UNLESS OTHERWISE NOTED. I. CONNECT NEW LIGHTS AS SHOWN. J. WIRE EXIT SIGNS/EMERGENCY LIGHTING UNITS AHEAD OF LOCAL SWITCHING/MOTION SENSOR CONTROL. K. ALL FIXTURES EXISTING TO REMAIN SHALL BE CLEANED AND RELAMPED. Q LIGHTING KEYNOTES: 1. NOT USED. 2. NOT USED. 3. NOT USED. 4. INSTALL SURFACE MOUNTED LUMINAIRE IN WALK-IN COOLER/FREEZER. SEAL COOLER PENETRATION AND INSTALL A LISTED CONDENSATION SEAL COMPATIBLE WITH WIRING. 5. NOT USED. 6. NOT USED. 7, NOT USED. B. INSTALL SURFACE -MOUNT EMERGENCY LIGHT/UNIT EQUIPMENT ON WALL @106" AFF. AIM LAMPS FOLLOWING THE INSTALLATION OF STORE FIXTURES TO LIGHT THE PATH OF EGRESS. CONNECT TO LOCAL LIGHTING CIRCUIT AND SUPPLY POWER TO BATTERY AHEAD OF ALL SWITCH LEGS. 9. SURFACE -MOUNT EXIT LIGHT IN COOLER. AIM LAMPS FOLLOWING THE INSTALLATION OF STORE FIXTURES TO LIGHT THE PATH OF EGRESS. CONNECT TO NEAREST LIGHTING CIRCUIT. SUPPLY POWER TO BATTERY AHEAD OF ALL SWITCHING. THE: E !'LA.NS A,yp ALL PROPO8SD WORK ARE SUBJECT TO ANY COMECTICNS R EOUIRLD BY PILL® NSPEC1IORS THAT KAY BE NECINAtlY IN ORDN TO COMPLY WITH ALL APPLICABLE CODES, CdNTRA&oR copy me 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM 91 ;TATE OF :�44/� 4 O R I Q p MAY 2 2 2015 a a� c 0 U 0 0 U @N bA �co m@'yx y0 200� o d 0 � r aVIWW - r ?� 6 �� ww ON ti 0 FF 2Z NW N ZO 3w w o[ i3 yo 0 }Q}y F2 z aw 0 ¢j y 10 w r� 0 o. w zo 30 Oa �O 2 N 0 rn Q O M LL. } Ur ¢ Lu Z = Z) C_7 —� 0 0 f '�7 STORE OR 6485 BLDG N0. VERSION OR AFE NO. SCALE: 0 4 DESIGN TEAM. DATE DGNR. J. YOUST 05-22.2015 PM./DP. D. TIMMER 05-22-2015 RVR./DP. G. HOLMAN 05-22.2015 DRWG. NO. E2 01 COMMUNICATION & SECURITY PLAN SCALE: 1/4" = V-0" i I I I I PHONE/DATA SCHEDULE TAG# DESCRIPTION P2 STORE 2ND (OFFICE & ATTENDANT PHONES) P3 POINT -OF -SALE CPU P.O.S. ACCESSORY P4 OFFICE COMPUTER P5 ATM P6 LOTTERY P8 MONEY ORDER MACHINE P10 VEEDER-ROOT. RED JACKET P13 L.E.D. READER BOARD P14 SPEEDY REWARDS P15 ELECTRONIC SAFE P16 INTERCOM STATION P18 R/F SYSTEM pig DVR p23 I LOYALTY PRINTER p24 I FAX MACHINE THESE PLki`IS AND ALL PROPOSSID WOVIK ARE SUBJECT TO ANY COE3rA ECTICNS REQUIRED BY FIELD NSPEC70PS THAT ULAY BE NECI!ti36AaY IN OlIlDe 1 TO COMPLY WITH ALL APPLICABLE CODES. GENERAL COMMUNICATIONS AND SECURITY NOTES: A. INSTALL ALL CONDUIT AND WIRING FOR DATA, COMMUNICATIONS AND SECURITY SYSTEMS PER'RESPONSIBILITIES LIST,' THIS SHEET, UNLESS OTHERWISE NOTED. B. ALL WIRING SHALL BE PERFORMED IN ACCORDANCE WITH NEC ARTICLE 352 FOR RIGID NON-METALLIC CONDUIT. C. ALL WIRING SHALL BE PERFORMED IN ACCORDANCE WITH NEC 800 SECTION V. D. COMMUNICATION CABLES SHALL NOT BE RUN IN SAME CONDUIT AS POWER CONDUCTORS. O COMMUNICATIONS & SECURITY KEYNOTES 1. NOT USED. 2. NOT USED. 3. NOT USED. 4. NOT USED. 5. NOT USED. 6. NOT USED. 7. PROVIDE (1)1" RNC AND (2) PAIR TELEPHONE CABLE FROM TELEPHONE BACKBOARD TO ATM. INSTALL DEVICE(S) AND MAKE FINAL CONNECTIONS. ATM RELOCATION MAY ALREADY BE COMPLETED BY OTHERS BEFORE REMODEL. VERIFY AT BID WALK. 8. PROVIDE (1)1" RNC AND (2) PAIR CAT-5 CABLE FROM NETWORK EQUIPMENT TO SPEEDY REWARDS. INSTALL DEVICE(S) AND MAKE FINAL CONNECTIONS. 9. VERIFY EXISTING ALARM SYSTEM SIGNALING DEVICE(S) ARE IN PROPER WORKING ORDER. ITEMS TO VERIFY INCLUDE: KEYPAD, MOTION SENSORS, DOOR CONTACTS AND PANIC BUTTONS. 10. NOT USED. 11. EXISTING SECURITY CAMERA TO REMAIN. 12, NEW OR RELOCATED SECURITY CAMERA. PROVIDE AND INSTALL SEPARATE DATA CABLES BETWEEN DVR AND EACH SECURITY CAMERA LOCATION. SUPPORT WIRING FROM STRUCTURAL CEILING. CABLES TO BE RG59/18-2, SIAMESE BLACK WITH 10' COIL AT EACH END. SPEEDWAY MAINTENANCE TO FURNISH AND INSTALL SECURITY CAMERAS. 13. NOT USED. 14. NOT USED. 15. NOT USED. 16. NOT USED. 17. EXISTING EMERGENCY STOP PUSH BUTTON. ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION V TELEPHONE/DATA OUTLET v DATA OUTLET. TELEPHONE OUTLET. JO JBOX. CEILING OR WALL MTD. SIZE AND TYPE AS REQD ® PANIC BUTTON SECURITY CAMERA - DOME STYLE Q SECURITY CAMERA - WEATHERPROOF BULLET STYLE SECURITY CAMERA - DIRECTIONAL STYLE �M MOTION DETECTOR DC DOOR CONTACT �K SECURITY KEYPAD ® EMERGENCY STOP PUSH BUTTON CONTRACTOR COPY md 7007 DISCOVERY BLVD DUBLIN, OH 43017 614,634.7000 T WDPARTNERS.COM B. 4 STATE OF : 44f FS'c� O R 1 P�: % MAY2,Y2015 Y Q m C 0 L N c 0 U fM coM bA Tc� m1rr= �ym0 c d c n �aruo cc a(nWW y 0 a o ¢S � d0 > 2= W F� W ND zW o 30 oa r� LW 0 Z Z �Lr) O Q o M ,LL 0- J ¢ LLI Off cZ G �.0 m 0 cf) 0 q STORE OR 6485 BLDG NO. VERSION OR AFE NO. SCALE: 0 4 DESIGN TEAM I DATE DGNR. J. YOUST 1 05.22-2015 PM./DP. D. TIMMER 05.22-2015 RVRJDP. G. HOLMAN 05-22-2015 DRWG. NO. E3 EX. PANELBOARD: A SIZE: 225 AMP MLO SERVICE ENTRANCE: NO MOUNTING: SURFACE LOCATION: ELECTRIC ROOM FEEDER: EXISTING CU SETS: LENGTH: 20 FT CONDUIT TYPE: ST VOLTAGE', 20SY/I2DV CONFIG: 3 PHASE 4 WIRE FED FROM, MOP DIRECTION: TOP OPTIONS', NONE NEMA: 1 TYPE: LIGHTING & APPLIANCE VOLTAGE DROP:. N/A NEUTRAL: 100% TVSS: NO BRANCH MOUNT', BOLT -ON BUS MATERIAL: CU EQUIPMENT NO. CIRGUIT N0. OC RATING a `� ag ¢ w a z. DESCRIPTION KW PER PHASE KW PER PHASE DESCRIPTION w w w0 b wEVAP-2 GO pAT NG C NOUIT EQUNPOMENT A B C A B C 1 20 1 10.8 OM EVAPS 2ti&2B 1.23 330 COOLER CONDENSER FE OM 333 3 2 X KT25YC 3 2 30 OM REMOTE ICE CUBE MACHINE 0.30 3.80 COOLER CONDENSER OM 33.3 3 45 4 X KT25YC 5 15 2 3.0 OM REMOTE ICE CUBE MACHINE 0.30 3,80 COOLER CONDENSER OM 33.3 3 6 X 7 3- E SPARE 1.87 REMOTE ICE CUBE MACHINE ON 18,9 2 30 8 KT25Y 9 20 3 E SPARE REMOTE ICE CUBE MACHINE OM 189 2 10 KT25Y14 3 E SPARE R1.87 0.36 COOLEREVAPORATOR E OM 3.2 1 20 12 XCU-3 13 2. 2.7 OM CONDENSER UNITNS 027 SPARE i 20 14 CU-3 15 2 2.7 OM CONDENSER UNIT#3 0.2F SERVEND 20 HEAD FOUNT OM 3.5 1 15 16 KT25S KBOH 17 2 20.0 KM FRZ CARS BEV FREEZER F>< 1.98 0.40 CONDENSATE PUMPS. E OM 3,5 1 20 18 X K80H 19 30 2 20D KM FRZ CARE BEV FREEZER 1.98 1.78 CONDENSER UNIT#2 OM 15.6 3 20 CU-2 KBOH 21 2 20.0 KM FRZ GARB BEV FREEZER 1.98. 1.7& CONDENSER UNIT#2 OM 15.6 3 25 22 GU-2 K80H 23 30 2 20.0 KM FRZ CARS BEV FREEZER 1.98 1.78 CONDENSER UNIT#2 CM 15.6 3 24 CU-2 X 25 20 1 6.0 R CIGARATTE DISPLAY 0.72 0.36jj�E RECEPTACLES E R 3.0 1 20 26 X X 27 15 1 5.3 OM E VACUUM 0.60 0.74 CARBONATOR OM 65 1 15 28 K25W,1 X 29 20 1 4.7 KM E DUNKIN CASE 0.54 1.20 AIR TOWER E OM 10:5 1 30 30 X X 31 20 i 10.0 KR E WARMER 1.20 0.60 VACUUM E OM 5.3 1 15. 32 X K44B 33 20 1 11.3 KM E DOUBLE DdOR FREEZER 129 0.36 COOLER LIGHTS E Li 3.2 1 15 34 X X 35 25. 1 12.5 WH E WATER HEATER 3:E ><I1.50. 0.36 FZR HEAT TAPE E H 3.0 i 15 36 X K44BR 37 20 1 11.3 CM DOUBLE DOOR FREEZER 1.29 0,36 FZR DOOR HEATERS E H 3.0 1 15 38 X -1 rpx 39 15 1 0.7 OM HW RECIRC PUMP 0.08 0.36 FZR DOOR HEATERS E H 3.0. 1' 15 40 X 41AI41B 20120 1 5.0 0 E EXISTING LOAD 0.60 0.36 BLOCKBUSTER E 0 3.0 1 20 42 X GROUND: SOLID SCCR: 42IAIC SPEC. SECTION 262416 DIVERSITY: 93% 15.4 KW -A 13.8 KW-B 15.2 KW-C BALANCE: 94% CONNECTED: 44.4 KW 128.9 AMPS PP 96% DEMAND: 412 KW 119.7 AMPS TYPE: H-HEATING, C-COOLING KR-KITCHEN RESISTIVE, KM -KITCHEN MOTOR, WH-WATER HEATER, OM -OTHER MOTOR, 1.1,1­2 OR 1-3-LIGHTING, TL-TRACK LIGHTING, S-SIGNS, SW -SHOW WINDOW, R-RECEPTACLES, SF -SUB FEED, 0-OTHER, E-EXISITNG SIZE: MLO-MAIN LUG ONLY, MCB-MAIN CIRCUIT BREAKER NOTE: GF-GROUND FAULT, AF-ARC FAULT, &EXISTING TC-VIA TIME CLOCK, ST-SHUNT TRIP, LC -LOCK ON, PC -PHOTO CELL CONTROLLED OPTIONS: SFL-SUB FEED LUGS, FTL-FEED THRU LUGS EX, PANELBOARD: C SIZE: 225 AMP MLO SERVICE ENTRANCE: NO MOUNTING: SURFACE LOCATION: ELECTRIC ROOM FEEDER: EXISTING CU SETS: LENGTH: 20 FT CONDUITTYPE'. ST VOLTAGE: 20BY1120V CONFIG: 3 PHASE 4 WIRE FED FROM: MOP DIRECTION: TOP OPTIONS: NONE NEMA: i TYPE', LIGHTING B APPLIANCE VOLTAGE DROP. NIA NEUTRAL: 100% TVSS: NO BRANCH MOUNT', BOLT -ON. BUS MATERIAL: CU EQUIPMENT NO. CIRCUIT NO. OC RATING W n a 8. r z DESCRIPTION KW PER PHASE KW PER PHASE DESCRIPTION w p z w m ¢ y n OC RATING CIRCUIT N0, EQUIPMENT NO. A B C A B C 1 1 3.0 0 E POS COMPUTBR 0.36 0.12 INTERCOM SVSTEM E 0 1.0 1 15 2 IC1 3 1 38 KR GF BUN WARMER 0.46 0.36 DUCT DETECTOR&HALL 0 3.0 1 15 4 X 5 1 2.5 0 E TIMER 0.30 1.82 MED TEMP MERCHANDISER GF OM 16.0 1 20 6 K34V rKlOi 7 r2O 1' 5.0 0 E. GCTV 0:60 0.12 SECURITY SYSTEM E 0 1.0 1 15 8 SEC-1 9 1 5.4 KR RETI11 DRAWER 065 0.34 BAG -IN -BOX RACK OM 3,0 1 15 10 K25X111 5.3 KM E GRINDER 0.60 RE 0,36 WALK-IN RECEPT. OF R 3D 1 20 12 X BM 13 20 1. 5.0 0 SPEEDY REWARDS O.fiQ. 0.36 i�E MANAGER COMP E 0 3.0 1 - 15 - 14 - X - X 15 20 1 3.2 KM E CHECKOUT 0.36 1.80 COFFEE MACHINE E ---- KM 18.2 2 30 16 X X 17 20 1 5.0 0 E SATELLITE DEI-CER 0.60 LBtr COFFEE MACHINE E KM 182 2 18 X .X 19 15 i 5.0 0 E ALLEDIGSMIDBOX 0.603:E 0.36igE POS COMPUTER E 0 3,0 1 15. 20 X X 21 15 1 3,0 0 E VCRIMONITOR TRAINING 0.36. j:E 1.80 EXPRESSO MACHINE E KM 18.2 2 30 22 X K21E 23 20 1 13.3 KM GF MICROWAVE OVEN 1.52' 1.80 EXPRESSOMACHINE E KM 18.2 2 24 X 94 25 20 1 2.1 0 E ATM TERMINAL 025 >< 0.36. DD COMP E 0 3.0 4 20 26 X K24Z 27 20 1 3.0 OM GF REF. C.TOP CONDIMENT UNIT 0.34 0.36 EXTERIOR RECEPT R 3.0 1 20 28. X K42A 29 20 1 13.9 OM. GF SINGLE DOOR FREEZER CHILLIICHEESE DISPENSER COFFE MACHINE 1.58 0,36 EPT. GF R. 3,0 1 20 30 X K148 31 20 1 1.7 OM GF 0.19 14.00 RD:D E SF 139.2 2 90 32 D X 33 2 18.2 KM E 1.80 3.00 RD: D nEE E SF 29,8 2 34 D X 35 30 2 18.2 KM E COFFE MACHINE 1.80 IP 36 K09M 37 20 1 16..0 KR OF ROLLER GRILLS 1.92 9,26 RD: E E SF 80.9 3 38 E K88E 39 20 1 6.8 KM GF ICE MERCHANDISER 0.78 8.70 ARD: E E SF 76.0 3 70 40 E K88E 41 20 1 6.8 KM GF ICEMERCHANDISER 0.7B 8,20 EX. PANELBOARD: E E SF 71'fi 3 42 E GROUND: SOLID SCCR: 42 kAIC SPEC. SECTION 262416 DIVERSITY: 87% 29.1 KW -A 21.1 KW-B 21.5 KW-C BALANCE: 79% CONNECTED', 71.7 KW 2070,AMPS PF: 96% DEMAND: 62.6 KW 180.5 AMPS TYPE: H-HEATING, C-COOLING,. KR-KITCHEN RESISTIVE, KM -KITCHEN MOTOR, WH-WATER HEATER, OM -OTHER MOTOR, 1­1,LZ OR LZ-LIGHI ING, I L-I KAGK uuH I INS, 5-NUIXP, Wv-anvvv vvINUUM R-RECEPTACLES, SF -SUB FEED, O-OTHER, E-EXISITNG SIZE: MLO-MAIN. LUG ONLY, MCB-MAIN CIRCUIT BREAKER NOTE: GF-GROUND FAULT, AF-ARC FAULT, E-EXISTING TC-VIA TIME CLOCK, ST-SHUNT TRIP, LC -LOCK ON, PC -PHOTO CELL CONTROLLED OPTIONS: SFL-SUB FEED LUGS, FTL-FEED THRU LUGS EX. PANELBOARD: D SIZE: 125 AMP MLO SERVICE ENTRANCE. NO MOUNTING: SURFACE LOCATION: ELECTRIC ROOM FEEDER: EXISTING CU SETS: LENGTH: 5 FT CONDUIT TYPE: ST VOLTAGE: 2081129V CONEG: 1 PHASE 3 WIRE FED FROM PANEL C DIRECTION: TOP OPTIONS: NONE NEMA: 1 VOLTAGE DROP: N/A NEUTRAL: 100% TVSS: NO BRANCH MOUNT: BOLT -ON BUS MATERIAL: CU EQUIPMENT N0, CIRCUIT NO. OC RATING rn a w a ¢ w a w z DESCRIPTION KW PER PHASE KW PER PHASE DESCRIPTION a 0 a1 OCCIRCUIT RATING N0. EQUIPMENT NO A B A B E .SPACE 1.10 FUEL DISPENSER#1 FE OM 9.6 1 203 2 X 0.0 E SWITCHED NEUTRAL 0.00 0.00 SWITCHED NEUTRAL 0.0 420 5 1 9.6 OM E FUEL DISPEN8ER#7 1.10 1.10 DISPENSER#2 OM 9.6 1 6ZO7 0.0 E SWITCHED NEUTRAL 0.00 0.00 SWITCHED NEUTRAL 0.0. 8 9 20' 1 9.6 OM E FUEL DISPENSER#8. 4,1p DISPENSER#3 E ON 9.6 1 ?0 10 11 0,0 E SWITCHED NEUTRAL 0I00 SWITCHED NEUTRAL E 0.0 12 13 20 1 9.6 OM E FUEL DISPENSER#0 1,10 DISPENSER#4 E OM 96 1 20 14 15 0,0 E SWITCHED NEUTRAL [E3 0.00 SWITCHED NEUTRAL E 0.0 16 17 20 1 8.6 OM E FUEL DISPENSE10 1.10. DISPENSER#5 E OM 9.6 1 20 18 19 2 ?5.0 KR E DUNKIN OVEN 0.00 SWITCHED NEUTRAL E 0.0 20 3021 2 25.0 KR E DUNKIN OVEN 1.10 DISPENSER#6 E OM 9.6 1 20 22 23 SPACE 0.00 SWITCHED NEUTRAL E 0.0 24 GROUND: SOLID SCCR: 22 IIAIC SPEC, SECTION 262416 DIVERSITY', 100% 14.0 KW -A 3.0 KW-B BALANCE: 30% CONNECT: 170 KW 84.5 A PF: 97% DEMAND: 17.0 KW 84.5 A TYPE: H-HEATING, C-COOLING, KR-KITCHEN. RESISTIVE, KM -KITCHEN MOTOI WH-WATER HEAT EK, UM-U I HEK MUI UK, LIXZ UK Ls-uOn I ING, TL.TmADK UGH iNG, S-SIGNS, Svi-SH0 v WiNvvv., R-RECEPTACLES, SF -SUB FEED, 0-OTHER, E-EXISITNG SIZE: MLO-MAIN LUO ONLY, MCB-MAIN CIRCUIT BREAKER NOTE: GF-GROUND FAULT, AF-ARC FAULT, E-EXISTING, F-FUTURE TC-VIA TIME CLOCK, ST-SHUNT TRIP, LC -LOCK ON, PC -PHOTOCELL CONTROLLED OPTIONS: SFL-SUB FEED LUGS, FTL-FEED THRU LUGS EX. PANELBOARD: B SIZE: 225 AMP MLO SERVICE ENTRANCE', NO MOUNTING: SURFACE LOCATION: ELECTRIC ROOM FEEDER: EXISTING CU SETS LENGTH'. 20 FT CONDUITTYPE: ST VOLTAGE', 208YI120V CONFIG: 3.PHASE4WIRE FED FROM. MOP DIRECTION: TOP OPTIONS: NONE NEMA: 1 TYPE: LIGHTING& APPLIANCE VOLTAGE DROP: N/A NEUTRAL: 100% LASS: NO BRANCH MOUNT: BOLT -ON BUS MATERIAL: CU EQUIPMENT N0. CIRCUIT N0, w OC w, RATING n w a t a o z DESCRIPTION KW PER PHASE KW PER PHASE DESCRIPTION w o z w w ¢ o n OC RATING CIRCUIT N0, EQUIPMENT N0. A B C A B C X 1 2 12.1 Li E YARD LIGHTING 1.20 0.90 FAST FOOD LTG E L1 79 1 15 2 X X 3 30 2 12.1 Li E YARD LIGHTING 1.20 0,60 CASHIER LIGHTING E Li 5.3 1 16 4 x X 5 20 1 10.5 Li E YARD LIGHTING I, 1,20 0.60 UTILITYIREST ROOM LTG E L1 5.3 1 15 6 _ x X 7 20 1 7.9 L1 E DECK LIGHTS 0.90 0.90 DECK LIGHTS E Li 7.9 1 20 8 x X 9 20 1 7.9 L1 E DECK LIGHTS 0.90 175< 0.90 DECKLIGHTS E Li 7.9 1 20 10 x X: 11 20 1 79 Li E DECK LIGHTS 0.90 i* 0.90 DECK LIGHTS E L1 7,9 1 20 12 X X 13 ZO 1 7,9 Ll E CANOPY FASCIA 0,90 0.90 CANOPY FASCIA E Li 7.9 1 20 14 X X 15 20 1 7.9 Ll E CANOPY FASCIA 0.90 0.90 CANOPY FASCIA E Ll 7.9 1 20 16 X X 17 20 1 7.9 L1 E CANOPY FASCIA 0,90 0.90 CANOPY FASCIA E Li 7.9 1 20 18 X X 19 15: 1 7.9 Ll E BUILDINGFASCIA 0.90 0.90 CANOPY FASCIA E Li 7.9 1 20 20 X X 21 15� 1 79 Li E BUILDING FASCIA 0.90 0,21 WALK-IN CAVE LTS Ll 1.8 1 20 22 X X 23 20 1 7,0 Ll E 10. SIGN HESS 0.80 0.90 PRICE SIGN E S 7.9 1 20 24 X X 25 20 1 5.3 Li E PAY PHONE LTG 0,60 0.90 HESS EXPRESS SIGN E S 7,9 1 20 26 X X 27 20 1 7.9 Li E SECURITY LTG, 090 0.90 WALL SIGN QSR E S 7.9 1 15 28 X X 29 15 1 7.9 S E WALL QSR 0.90 0,90 CANOPY FASCIA E L1 7.9. 1 20 30 X X 31 15 1 7,9 Li E SALES LTG. 0.90 0.90 CANOPY FASCIA E Li 7.9 1 20 32 X 33 20. 1 70 Li E SECURITY LTG. 0.90 090 CANOPY FASCIA E Li 7.9 1 20 34 X 35 15 1 70 S E NEON"HESS EXPRESS' 0,80 0.90 CANOPY FASCIA E Li 79 1 20 36 X Lxx 37 20 i 6.7 H WALK-IN CAVE DR HTR 0.80 0,90 CANOPY FASCIA E L1 7.9 1 20 38 X 39 20 1 3.5 Li WALK-IN CAVE DR LTS 0.40 0.90 LTG CONTACTOR POWER E R 7.5 1 15 40 X 41 15 1 7,9 Li E SALES LTG. 0.90 0,90 ATRIUM LIGHTING E L1 7.9 1 15 42 1 X GROUND: SOLID SCCR, 42 kAIC SPEC. SECTION 262416 DIVERSITY: 124% 12b KW -A 11,4 KW-B 12,4 KW-C BALANCE: 94% CONNECTED: 36.3 KW 105.8 AMPS PF: 95% DEMAND:. 45.0 KW 131.1 AMPS - -14A TYPE: H-HEATING, C-COOLING, KR-KITCHEN RESISTIVE, KM -KITCHEN MOTOR, WH-WATER HEATER, OM -OTHER MOTOR, 1­1,1­2 OR -3-LIGHTING, TL-TRACK LIGHTING, S-SIGNS, SW -SHOW WINDOW, - R FAULT E-EXISTING LT AF A C R NOTE: GF-GROUND FAULT, , R-RECEPTACLES, BF -SUB FEED, 0-OTHER, E-EXISITNG SIZE: MLO-MAIN LUG ONLY, MCB-MAIN CIRCUIT BREAKER TC-VIA TIME CLOCK, ST-SHUNT TRIP, LC -LOCK ON, PC -PHOTOCELL CONTROLLED OPTIONS: SFL-SUB FEED LUGS, FTL-FEED THRU LUGS EX. PANELBOARD: E SIZE: 125 AMP MLO SERVICE ENTRANCE: NO MOUNTING: SURFACE LOCATION: ELECTRIC ROOM FEEDER: EXISTING CU SETS: LENCTH. 20 FT CONDUIT TYPE: ST VOLTAGE', 238YI120V CONFIG, 3 PHASE 4 WIRE FED FROM, C DIRECTION: TOP OPTIONS, NONE NEMA: 1 TYPE: LIGHTING & APPLIANCE VOLTAGE DROP: NIA NEUTRAL: 100% TVSS: NO BRANCH MOUNT, BOLT -ON BUSMATERIAC CU EQUIPMENT N0. CIRCUIT NO. ,� OC RATING a w ¢ w a o z DESCRIPTION KW PER PHASE KW PER PHASE DESCRIPTION r i a w m a J 0 a CC RATING CIRCUIT NO. EQUIPMENT N0. A B C. A B C X 1 3 15.8 OM E STP I UNLEADED. 1,80 2.00 ICE TEA EREWER E KM 20,2 ? 30 2 X X 3 20 3 15.8 OR E STP 1 UNLEADED 1.80 200 ICE TEA BREWER E KM 20.2 2 4 X X 5 3 15.8 OM E STP 1 UNLEADED 1.80 1,50 HOT CHOCOLATE E KM 15.2 2 20 6 X X 7 3 15.8 OM E STF 2 PLUS 1,80 1.50 HOT CHOCOLATE E KM 152 2 8 X X 9 20 3 15.8 OM E. STP 2PLUS 1,80 1,00 TOASTER E KR 9.6 2 20 10 X X 11 3 15.8 OM E STP 2PLUS 1.80 1.00 TOASTER E KR 9.6 2 12 X X 13 3 15,8 OM E STP3PREMIUM 1.80 0.36jj:� COMPUTER E. 0 3.0 1 15 ib X X 15 20 3 15.8 OM E STP3 PREMIUM 1.80 0.30 FLAVOUR MACHINE E KM 2.6 1 20 i6 X X 17 3 15.8 OM E STP3PREMIUM 1.80 0,30 CREAMER MACHINE E KM 2.6 1 20 18 X 19 E' SPACE SPACE E 20 21 E SPACE SPACE E 1 22 23 E SPACE SPACE E 24 GROUND: SOLID SCCR: 42 kAIC SPECSECTION 262416 DIVERSITY: 89% 9,3 KW -A 8.7 KW-B 82 KW-C BALANCE: 93% CONNECTED: 26Z KW 76A AMPS PF: 95% DEMAND: 23,3 KW 67S AMPS TYPE: H-HEATING, C-COOLING, KR-KITCHEN RESISTIVE, KWKITCHEN MOTOR, WH-WATER HEATER, OM -OTHER MOTOR, L1,1­2 OR L3-LIGHTING, TL-TRACK LIGHTING, S-SIGNS, SW -SHOW WINDOW, R-RECEPTACLES, SF -SUB FEED, O-OTHER, E-EXISITNG SIZE: MLO-MAIN LUG ONLY, MCB-MAIN CIRCUIT BREAKER NOTE: GF-GROUND FAULT, AF-ARC FAULT, E-EXISTING TC-VIATIME CLOCK, ST-SHUNT TRIP, LC -LOCK ON, PC -PHOTO CELL CONTROLLED OPTIONS: SFL-SUB FEED LUGS, FTL-FEED THRU LUGS THE E rLA,NS AJND ALL PROPOSsD rjoHIa ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY PIELD NSPECXRS THAT GGAY BE NECL"S"Y It/ ORtL" TO COMPLY WITH ALL APPLICABLE CODES, CONTRACTO COPY 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS,COM \\\\`ov � B. /yo • Z L.,--*CCEEN`S12'/,'tl�yi: . yr .510 N A� 1101111111\ MAY 2 2 2W5 fl. 0) 0 O U 7 L w C U M �N 0� TG� m 3'Qx a�)mo c 0)bA0 a0ww V J W Lo O cof� � J L u %- 11 _ � U U = c U J J = ~ W pm ■ STORE O BDGN6485 LDG NO.. VERSION OR APE NO. SCALE: DESIGN TEAM DATE DGNR. J. YOUST 05-22-2015 PM./DP. D.TIMMER 05-22-2015 RVR./DP. G. HOLMAN 05-22-2015 DRWG. NO. E4 MECHANICAL EQUIPMENT SCHEDULE EQUIPMENT IDENTIFICATION EQUIPMENT ELECTRICAL CHARACTERISTICS EQUIPMENT CIRCUIT EQUIPMENT STARTING & PROTECTION EQUIPMENT DISCONNECT EQUIP. CONTROL OOP BRANCH CIRCUIT SIZE N 00 LOCATION D N LOCATION W C S 0 E M I I E C W 0 T E N M B N M U N 0 U N R p N A R E. A E P S 0 A E P P S N V P S B L ¢ 1° R D R L M N Q. P T N Q q P T T 0 P T T P S. V w E U T 0 A. E A R 8 L A N S E U R N L A R L L A NOTES Y H 0 A M LL S E N T U E U L N E E L 0 L TAG EQUIPMENT NAME A L MAX HP I KW C �„ m T R A C M M. S I L E Z C M L L L T L P S W T R A w T BRANCH CIRCUIT T D S L 0 P C E E C E L P B E E A E E E E I S T T 0 N 0 C W D D T 0 0 D D T E D D. A h S P T Z E T A E T 0 G m E Y 1''. Y E S N E Y B T S N E A B Y B R z P P P U. T T Y B Y U T R Y B P Y B' D - E E R Y Y R D Y E Y E E P E E E 94 O ATM TERMINAL 1 3 120 2.1 0.3 2-.6 15 20 1 #12 W/#12 G IN 3/4' C. CU ST V V V V IN V V 8M 0 SPEEDY REWARDS 1 3 120' 5.0 0.6 6.3 20 - 20 1 #12 W/#12 G IN 34' C CU ST V V V V IN V V CU-IAICU-iB OM CONDENSER UNIT#1 1 3 120 2.7 0.3 3.4 15 15 1 #12 W/#12 G IN 314" C, CU ST V V 30 3R E) C C IN V V 2' CU-2 OM . CONDENSER UNIT#2 3 4 208 15.6 5.3 19.5 25 25 1 #12 W/#12 G IN 3I4" C. CU ST V V ]NF 30 IR D C C IN V V CU-3 OM CONDENSER UNIT#3 1'. 3. 208 2.7 0.5 &4 15 15 1 #12 W/#12 G IN 3I4"C. CU ST V V 30 3R D C C' IN V V 3 EVAP-2 OM EVAPS ZA & 2B 1 3 120 10.8 1.2 13.5 20 20 1 #12 WI#12G IN 3/4" C. CU ST V V 15 1 D C C IN V V RP-1 OM HW RECIRC PUMP 1 3 120 1/25 0.7 01 09. 15 15 1 #12 WI#12 G IN 3/4"C. CU ST V V M 30 1 D C C IN RTU-1 H ROOF TOP UNIT#1: 3 4 208 64.0 231 640 80 80 EXISTING CU ST V V D V V WT 24 C C 1 TYPE: H HEATING C-COOLING,KR-KITCHEN RESISTIVE,. KWKITCHEN. MOTOR, WH-WATER HEATER, OM -OTHER MOTORS STARTER TYPE: M-MANUAL, FM -FRACTIONAL MANUAL, IM-INTEGRAL MANUAL, C-CONTACTOR, NR-NON-REVERSING, REV-REVERSING,RV-REDUCED VOLTAGE SOFT START, VFD-VARIABLE FREQUENCY DRIVE OVERLOAD TYPE: OL-BUILT-INTHERMAL OVERLOAD, MA -MELTING ALLOY, SS -SOLID STATE (REFER TO MOTOR NAMEPLATE DATA FOR. PROPER OVERLOAD SIZING) COMBINATION TYPE: N-NONE, F-FUSED, NF-NON-FUSED, MCCB-MOLDED CASE CIRCUIT BREAKER DISCONNECT TYPE: HP -HP RATED SWITCH, C&P-CORD &PLUG, LC&P-LOCKING CORD, PLUG, F-FUSED, NF-NON-FUSED, MCCB-MOLDED CASE CIRCUIT BREAKER, EL -ELEVATOR CONTROL SWITCH CONTROL TYPE: M-MANUAL, IL -INTERLOCKED, IN -INTEGRAL, IT -INTEGRAL THEROMOSTAT, ET -EXTERNAL THERMOSTAT, TC-TIME CLOCK, DDC-DIGITAL SUPPLIED/INSTALLED BY: ECGELECTRICAL CONTRACTOR HC-HVAC CONTRACTOR,PC-PLUMBING CONTRACTOR', FPC-FIRE PROTECTION CONTRACTOR, ES -EQUIPMENT SUPPLIER, ATC-AUTOMATIC TEMPERATURE CONTROLS CONTRACTOR "VOLTAGE DROP CALCULATION FORMULAS COURTESY OF COOPERBUSSMANN. NOTES: 1-EXISTING 2-POWERED FROM ICE MAKER 3-POWERED FROM FREEZER 0 COMMERCIAL KITCHEN EQUIPMENT SCHEDULE EQUIPMENT IDENTIFICATION EQUIPMENT ELECTRICAL CHARACTERISTICS EQUIPMENT CIRCUIT EQUIPMENT DISCONNECT OOP BRANCH CIRCUIT SIZE LOCATION W C S I W 0 U N R F I N E IF P S P E V L w E D U T S N R A N T A T H S 0 A M w L NOTES TAG Y P EQUIPMENT NAME A W L MAX HP / KW C y m S E T P Z M I M L I L S 7 R A g m BRANCH CIRCUIT T E E A 0 B E E E / S w m S Y T M T 0 D D G A F z E P N E R: Rt N T Y 8 D E D Y K09L KR RETHERM DRAWER 1 3 120 5.4 0B 6.8 20 20 1 #12 W/#12 G IN 314" C. CU ST C&P 15 5-15 1 D V V 2 K09M KR ROLLER GRILLS 1 3'. 120 16.0 1.9 16.0 20 20 1 #12 W/#12 G IN 3/4'' C. CU ST - C&P 20 5-20 D V V 2 K10I KR BUN WARMER 1 3 120 3.8. 0,5 4.8 20 20 1 012 Wl#12 G IN 3/4" C. CU ST C&P 15 5-15 D V V 2 K21E KM MICROWAVE OVEN 1 3 120 13.3 1,5 16.6 20 20 1 #12 WI#12G IN 34'C. CU ST C&P 20 5-20 D V V 2 K24Z OM. REF. C TOP CONDIMENT UNIT 1 3 120 3.0. 0.3 3.8 20 20 1 #12 W/#12G IN 314"C. CU ST C&P 15 5-15 0 V V 2 KT25S OM SERVENDP20 HEAD FOUNT 1 3 120 3.5 0.4 4.4 15 15 1 912 WI#12G IN 3/4'C. CU ST C&P 15 5-15 D V. V 2 K25W.1 OM CAR13ONATOR 1 3 120 6.5 07' &1 15 15 1 #12 W/#12 G IN 3/4' C. CU ST C&P 15 5-15 D '9 V V 2 K42A OM SINGLE DOOR FREEZER 1 3 120 13.9 1.6 17.4 20 20 1 #12 Wl#12 G IN 3W C. CU ST C&P 20 5-20 0 V. V 2 K448 OM DOUBLE DOOR FREEZER 1 3 1 120. 11.3 1.3 141 20 20 1 #12 Wi#I 2 G IN 3W C. CU ST C&P 16 5-15 0 V V 2 K80H KM FRZ CARIB BEV FREEZER 1 3 208 20.0 4.0' 25.0 30 30. 1 #10 W/#10 G IN 3W C. CU ST LC&P 30 L6-30 D V V 2 K88E KM ICE MERCHANDISER 1 3; 120 68 0.8 8.5 20 20 1 #12 W/#12 G IN 314" C. CU ST C&P 15 5-15 0 "• V V 2 K44BR OM DOUBLE DOOR FREEZER 1 3 120 11.3 1.3 14.1 20 20 1 #12 W/#12 G IN 3/4" "C, CU ST C&P 15 5-15 0 V V 2 KT25Y OM REMOTE ICE CUBE. MACHINE. 1 4 208 18.9 3.7 23.6 30 30 1 #10 W1#10G IN 3/4"C, CU ST C&P 30 14-30 D ES- ES 4 KT25YC ON REMOTE ICE CUBE MACHINE 1 4 208 100 2:0 12.5 15 15 1 #12 WI#12G IN 34' C. CU ST C&P 20 14-20 E) ES ES 4 TYPE: H-HEATING, C-COOLING,. KR-KITCHEN RESISTIVE, KM -KITCHEN MOTOR, WH-WATERHEATER, OM -OTHER MOTORS, O-OTHER DISCONNECT TYPE: HP -HP RATED. SWITCH, CRP -CORD & PLUG, LC&P-LOCKINGCORD & PLUG, F-FUSED, NF-NON-FUSED, MCCB-MOLDED CASE CIRCUIT BREAKER SUPPLIEDIINSTALLED' BY: EC -ELECTRICAL CONTRACTOR HC-HVAC CONTRACTOR, PC -PLUMBING CONTRACTOR, ES -EQUIPMENT SUPPLIER `VOLTAGE DROP CALCULATION FORMULAS COURTESY OF COOPER BUSSMANN. NOTES', 1- REQUIRES SHUNT TRIP PROTECTION 2-CORD & PLUG SUPPLIED AND INSTALLED BY ES. EC SHALL PROVIDE RECEPTACLE. 3- CORD & PLUG SUPPLIED AND INSTALLED BY ES. RECEPTACLE SUPPLIED BY ES AND INSTALLED BY EC. 4-CORD, PLUG & RECEPTACLE SUPPLIED AND INSTALLED BY EC. 5 - SINGLE PHASE, THREE WIRE EQUIPMENT. PROVIDE NEUTRAL CONDUCTOR AND GROUND 6 -THREE PHASE, FOUR WIRE EQUIPMENT. PROVIDE NEUTRAL CONDUCTOR AND GROUND, 7- OUTLETS SUPPLIED AND INSTALLED BY ES, CONDUIT& WIRING PROVIDED BY EC. B-FUTURE :w NEC ELECTRICAL LOAD SUMMARY ELECTRICAL LOAD CONNECTED NEC DEMAND USE NEC REFERENCE LIGHTING ZONE-L1. VAIFT2 3.00 30,570 38,213 ST 220.12,42 LIGHTING ZONE-1_2 VA/FT2 0,00 0 0 220.12,42 LIGHTING ZONE-L3 VAIFT2 0,00 0 0 0 220, 12,42 220.43(8) TRACK - TL(FT) 0 SIGNS -S(EA) 7 4,400 7,980 220.14(F) SHOW WINDOW -SW (FT) oil 0 220.14(G)143(A) OF = DIVERSITY FACTOR RECEPTACLES -R 3,060 3,060 100% 220.14(H,I&K),44 KITCHEN RESISTIVE'-KR 12,224 7946 65% 220.56 KITCHEN MOTORS -KM 32,159 20,903 65% 220.56 COOLING MOTORS -C 0. 0 100% 220.40,50,60 HEATING -H' 24,937 24,937 100% 220,40,50,51,60 OTHER MOTORS -OM 59,993 59,993 100% 220.40,50 MAX MOTOR HP 2 N/A 1 215 220A0,50 WATER 'HEATERS -WH 1,500 11500 100% 220.40 OTHER-0 6,672 6,672 100% 220.40 TOTAL KW 175.5 171A POWER FACTOR: 96% LIGHTING AREA - Al Z500 FT2 LIGHTING -L4 12.23 W/FT2 LIGHTING AREA -A2- FT2 LIGHTING -L2 0.00 W/FT2 LIGHTING AREA AS FT2 LIGHTING -L3 0.00 W/FT2 LIGHTING AREA 2.800 FT2 TOTAL LIGHTS: 12.23 W/FT2 COOLING AREA. 2,600 FT2 .COOLING -C 0.00 W/FT2 HEATING AREA 2,500 FT2 HEATING -H 9B7 W/FT2 CONNECTED', 70,21 WIFT2 NEC DEMAND: 68.57 WIFT2 SYSTEM VOLTAGE'. 208 VOLTS PHASES: 3 CONNECTED, 505.8 AMPS NEC DEMAND: 493.9 AMPS MOTOR CONTRIBUTION: 92.2 KW' CONFIGURATION: 3PHASE 4WIRE USE: A -ARMORIES AND AUDITORIUMS, B'-BANKS,. BS-BARBER SHOPS AND BEAUTY' PARLORS, CH -CHURCHES, CL-CLUBS, OR -COURT ROOMS, DU -DWELLING UNITS, GGARAGES, HOS-HOSPITAL, HM-HOTEUMOTEL, ICB-INDUSTRIAL COMMERCIAL (LOFT) BUILDINGS, _R-LODGE ROOMS, OB-OFFICE BUILDING, RS-RESTAURANTS, SC -SCHOOLS, ST-STORES, W-WAREHOUSE AH-ASSEMBLY HALLS AND AUDITORIUMS', HC-HALLS, CORRIDORS,CLOSETS, STAIRWAYS, SS -STORAGE SPACES. EX. DISTRIBUTION PANELBOARD: MDP SIZE: 600 AMP MLO FEEDER: EXISTING CU SETS: GF PROTECTION': NO NEMA: 1 SERVICE ENTRANCE: YES LENGTH: 20 FT CONOUITTYPE', ST NEUTRAL: 100% VOLTAGE DROP: N/A 'MOUNTING: SURFACE VOLTAGE: 20BY/120V CONFIG: 3PHASE4WIRE SEISMIC: NO TVSS: NO FUNGUS PROOF: NO FEED TYPE: CABLE PULL SECTION: NO UTILTIY METERING: YES UTILITY: LOCATION: ELECTRIC ROOM FED FROM: UTILITY DIRECTION: BOTTOM CUSTOMER METERING', NO BUS MATERIAL: CU w S o m FEEDER SIZE KW PER PHASE CIRCUIT DEVICE DESCRIPTION PF NOTES NO. TYPE w a LL a SETS CABLEBUSWAY A BTO 1 MCCB 225 200 ABC SF EX. PANELBOARD: A 128.9 EXISTING 15.4 13.8 15.2 96% 1 2 MCCB 225 200 ABC SF EX. PANELBOARD: C 207.0 EXISTING 29.1 21,1 21,5 96% 1 3: MCCB 225 200 ABC SF EX. PANELBOARD: B 105.8 EXISTING 125 11,4 12.4 95% 1 4 SPACE 5 MCCB 100 BO ABC H ROOF TOPUNIT#1 64.0 EXISTING 7.7 7.7 7.7 10tl% i 6 SPACE GROUND: SOLID BALANCE: 89% CONNECTED: 175.5 KW 505.8 AMPS 647 54,0' 568 SPEC. SECTION' SOCK 65 kAIC PF', 96% DEMAND: 171.9 KW 495.3 AMPS 26 24 16 DIVERSITY: 98% TYPE: H-HEATING, C-COOLING, KR-KITCHEN RESISTIVE, KM -KITCHEN MOTOR, WH-WATER HEATER, OM -OTHER MOTOR, L1,L2 OR 1-3-LIGHTING, TL-TRACK LIGHTING, SSIGNS, SW -SHOW WINDOW, R-RECEPTACLES, SF -SUB FEED, O-OTHER E-EXISTING SIZE: MLO-MAIN LUG ONLY, MCB-MAIN CB, MFS-MAIN FUSED SWITCH- DEVICE TYPE: FS-FUSIBLE SWITCH, MCC134OLDED CASE CB NOTES: 1. EXISTING OUTSIDE BUILDING ELECTRICAL CLOSET OUTSIDE EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING PANEL PANELW PANEL'B' " PANEL'C' PANEL'D' PANEL'E' POLE 'MDP' 225A 225A 225A 100A 1UOA MOUNTED SODA 208YI120V 208Y/120V 208Y/120V 120V - 20BY1120V UTILITY 20BY/120V 30,4W 30,4W 30,4W 10,3W 30,4W TRANSFORMER M EXISTING 30AW MLO MLQ MLO MLO MLO 208Y/120V - 600A, MLO 30,4W EXISTING TRANSFER ENERGY SWITCH METER. - & CT CABINET EXISTING m. EXISTING v GENERATOR TAP BOX EXISTING I....�...___ GROUNDING TO REMAIN RISER DIAGRAM THC:::1PLABS AND ALL PROPOSSD WA WK ARE SUBJECT TO ANY COMECTICNS REQUIRED BY PIELD INSPEC11OIRS THAT MAY BE NEC!•NMY IN ORDLO R TO COMPLY WITH ALL APPLICABLE CODES. m z 0 0 7007 DISCOVERY BLVD DUBLIN, ON 43017 614.634.7000 T WDPARTNERS.COM Nc 7401111111 STATE OF :�44/, O A, i�",5'0 N A L e.'%%% MAY 2 2 2015 O LO G4 T ro0 00[V= Syc� �aa�nuo aLlIWW y R�1 LLI J rn o m U) LULU Q �LL ¢ Lu U W = F- 00 to CL yo STORE OR 6A 85 BLDG NO..vl�o VERSION OR AFE NO. SCALE: 0 4 I DESIGN TEAM I DATE I DGNR. J. YOUST 1 05-22.2015 PM./DP. D. TIMMER 05-22.2015 RVR./DP. G. HOLMAN 05-22.2015 SCALE: N.T.S. E5