HomeMy WebLinkAboutREVISION 10-29-15.4
- n
J
01
MEN
1.
4 s HALL UTILITY
17 23 35 6
4 8 17
4 17 28
0 EIF 23
o I
WOMEN
9M, '
4 9
17 23 35
uL-
STORAGE
KIM
J 4 9
17 23
�lol�
_ r I r j2HEATq� II I
n r I I I I I I I 9ERVENb I II
u LJ-� L__J LDJ LJ II I
y_ -�- _-
�
ATTENDANT
J
I ffri r
1
1 4 17
TYP
I 28
El
STORAGE
4 9
17 35
I
I
I
O
a 2.0 cc
5 6 5 6
\ \ / \
II II I
--�.�---_-_JL_--JL__-_J
z7 5
6 3
I II II II I I I
I II II II I I I �
37 �
// /
5 6
\>
2
SALES
uwWl AREA /
4 17 28 �
38
- - - - - - - - - - - I L_
FLOOR DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
6 6 0
r-
nr
WALK4N
COOLER
ffm
'ALK-IN 1
IE�E--ZER
Oar J
FLOOR DEMOLITION PLAN NOTES:
1. EQUIPMENT / FURNITURE TO REMAIN. COORDINATE ANY REPAIRS WITH PROJECT MANAGER,
2. EQUIPMENT / FURNITURE TO BE REMOVED AND STORED IN A SAFE PLACE TO BE REINSTALLED IN NEW LOCATION PER REMODEL
PLANS. COORDINATE WORK WITH PROJECT MANAGER. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND INSTALLATION
OF EQUIPMENT PER PLANS AND INSTRUCTIONS OF PROJECT MANAGER. REMOVE ALL PLUMBING AND ELECTRICAL ASSOCIATED
WITH EQUIPMENT BACK TO SOURCE UNLESS OTHERWISE NOTED ON PLUMBING AND ELECTRICAL DRAWINGS.
3. EQUIPMENT / FURNITURE TO BE REMOVED. COORDINATE WORK WITH PROJECT MANAGER. GENERAL CONTRACTOR SHALL BE
RESPONSIBLE FOR REMOVAL AND DISPOSAL OF EQUIPMENT UNLESS OTHERWISE INSTRUCTED BY PROJECT MANAGER. REMOVE
ALL PLUMBING AND ELECTRICAL ASSOCIATED WITH EQUIPMENT BACK TO SOURCE UNLESS OTHERWISE NOTED ON PLUMBING
AND ELECTRICAL DRAWINGS,
4. WALL(S) / PARTITION(S) TO REMAIN. REFER TO FLOOR PLAN FOR EXTENT OF NEW WORK REQUIRED ON EXISTING WALL. FINISH
MATERIALS TO REMAIN UNLESS OTHERWISE NOTED. REFER TO FINISH PLAN.
5. PROJECT MANAGER AND CONTRACTOR SHALL COORDINATE WITH MARKETING DEPARTMENT FIELD MERCHANDISER FOR
REMOVAL OF EXISTING GONDOLA EQUIPMENT.
6. REMOVE MERCHANDISING AND STORAGE RACKS, AND/OR SHELVING. COORDINATE WITH PROJECT MANAGER FOR REUSE OF
SHELVING AND STORAGE OF MERCHANDISE. GONDOLA SHELVING RELOCATION MAY ALREADY BE COMPLETED BY OTHERS
BEFORE REMODEL. VERIFY AT BID WALK.
7. NOT USED
8. NOT USED
9. EXISTING EQUIPMENT AND FURNITURE TO REMAIN AS IS.
10. REMOVE WALL FINISHES, GRAPHICS, AND APPLICATIONS TO ALLOW FOR INSTALLATION OF NEW CABINETRY AND/OR
MERCHANDISING EQUIPMENT, INSTALL STRAIGHT AND PLUMB. REFER TO FINISH PLAN. COORDINATE WITH PROJECT MANAGER.
11. REMOVE WALL / PARTITION. REMOVE ACCESSIBLE GAS, PLUMBING, ELECTRICAL, AND TELEPHONE FEEDERS PER ELECTRICAL
DEMOLITION PLAN. CAP ALL INACCESSIBLE UTILITIES PER APPLICABLE CODES AND INDUSTRY STANDARDS.
12. REMOVE COOLER PANELS AND COOLER DOORS AS NEEDED FOR NEW COOLER LAYOUT.
13. REMOVE FREEZER DOOR.
14. NOT USED
15. NOT USED
16. NOT USED
17. EXISTING FLOOR TILE TO REMAIN.
18. EXISTING SIDEWALK TO REMAIN.
10 MOT I ICGIj
20. NOT USED Q3
21. Ivdl uS1=b
22. REFER TO MPE DRAWINGS FOR EXTENT OF MECHANICAL, PLUMBING, AND ELECTRICAL DEMOLITION.
23• EXISTING PLUMBING FIXTURES TO REMAIN.
24. NOT USED
25. NOT USED
26. NOT USED
27. REMOVE EXISTING EVAPORATOR FOR RELOCATION. DISCONNECT POWER AND REFRIGERANT PIPING. REFER TO MECHANICAL
SHEETS.
28. EXISTING CAMERAS AND SPEAKERS TO REMAIN.
29. NOT USED
30. EXISTING ELECTRICAL EQUIPMENT TO REMAIN.
31. NOT USED
32. REMOVE EXISTING COOLER DOORS AND 5-DOOR FRAME. STORE THE FOUR BEST COOLER DOORS FOR REUSE.
33. NOT USED
34. NOT USED
35. NO DEMOLITION IN THIS AREA.
36. EXISTING CANOPY TO REMAIN.
37. EXISTING COOLER/FREEZER EVAPORATORS TO REMAIN.
38. REMOVE METAL COLUMN COVERS AND ACCESSORIES.
39. NOT USED
40. NOT USED
FLOOR DEMOLITION LEGEND
O SEE DEMOLITION PLAN NOTES - _ - EXISTING WALLS, EQUIPMENT,
- FURNITURE, & ETC. TO BE
REMOVED
EXISTING WALLS, EQUIPMENT, F- - I APPROXIMATE LOCATION OF
FURNITURE, &ETC. TO REMAIN L _ J CONCRETE SLAB SAW CUTS THESE PLANS AND ALL PROPOSED t"JORf
ARE SUBJECT TO ANY COMECT;ONS
REQUIRED BY FIELD INSPECXRS THAT
MAY BE NECMSAS1Y IN Of4MM TO
GO;:;r LY U;1TH ALL A?PLIGAiZIE CODES.
FLOOR DEMOLITION GENERAL NOTES:
A. THESE DRAWINGS DO NOT INDICATE THE FULL EXTENT OF THE WORK DETAILS REQUIRED TO COMPLETE THIS REMODEL
PROJECT. VERIFY EXISTING CONDITIONS FOR THE FULL EXTENT OF THE WORK REQUIRED TO COMPLETE THIS PROJECT IN A
WORKMANLIKE MANNER PER ALL APPLICABLE CODES AND THESE DRAWINGS. COORDINATE WORK WITH THE PROJECT
MANAGER.
B. DEMOLISH EXISTING CONSTRUCTION ONLY TO THE EXTENT NECESSARY TO COMPLETE THE NEW CONSTRUCTION. CUT BACK
EXISTING FINISHED SURFACES TO SQUARE, LEVEL, AND PLUMB LINES.
C. CAREFULLY REVIEW PLANS AND DETERMINE UTILITIES THAT ARE REQUIRED TO BE DISCONNECTED AND THOSE THAT WILL
REMAIN FUNCTIONAL. COORDINATE WORK WITH THE APPROPRIATE UTILITY PROVIDER. SCHEDULE WORK FOR A MINIMUM OF
INTERRUPTION,
D. REMOVE AND SECURE ALL GAS, PLUMBING, ELECTRICAL, AND OTHER UTILITIES ASSOCIATED WITH EQUIPMENT REMOVED FROM
SITE. INSTALL REQUIRED MATERIALS TO SECURE AND MAKE SAFE ALL UTILITIES TO REMAIN.
E. PREVENT PUBLIC ACCESS TO THE WORK AREA. INSTALL BARRIERS AND SIGNAGE TO ALERT THE GENERAL PUBLIC, EMPLOYEES,
AND CONTRACTORS OF DANGERS.
F. GENERAL CONTRACTOR SHALL PROTECT ALL EQUIPMENT THAT WILL REMAIN FOLLOWING REMODEL BY PLACING IT IN STORAGE
FOR THE DURATION OF THE PROJECT. COORDINATE WITH THE PROJECT MANAGER.
G. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING WORK PERMITS AND COMMUNICATING WITH UTILITY PROVIDER(S) PRIOR
TO ANY WORK AFFECTING SERVICES. FIELD VERIFY LOCATION OF ALL SERVICES.
H. CONTRACTOR SHALL VERIFY w/ PROJECT MANAGER ALL EQUIPMENT & FURNITURE TO BE REMOVED AND RELOCATED PRIOR TO
COMMENCING WITH THE WORK.
I. ANY WALLS BEING PROPOSED FOR REMOVAL SHALL BE CONFIRMED BY THE CONTRACTOR AS BEING NON -LOAD BEARING
BEFORE PROCEEDING WITH REMOVAL. IF LOAD -BEARING WALLS) ARE FOUND DUE TO UNFORESEEN CONDITIONS, IT SHOULD BE
BROUGHT DIRECTLY TO THE PROJECT MANAGER'S ATTENTION BEFORE PROCEEDING WITH THE REMOVAL OF THAT WALL. NOTE:
THE ARCHITECT HAS MADE ASSUMPTIONS BASED ON PREVIOUS DRAWINGS AND THE EXISTING CONDITIONS THAT ARE VIEWABLE.
HE HAS USED HIS BEST JUDGMENT TO DETERMINE ALL LOAD -BEARING WALLS.
FILE COPY
0
O
N
I
M
7007 DISCOVERY BLVD
DUBLIN, OH 43017
614.634,7000 T
WDPARTNERS.COM
K.
OCT 21
2W
a
0
0
0
U
3
N
0
0
U
M
Mm
np
TCO
mf6y=
a-p yO
�yc�
aa)uo
a :%i Lu W
=N
O
H U.)
O
J
co
Z
Q
C I
W
Lu JQ
2
O
_�
1
(00 Dom..
ILL.
STORE OR 6485
BIDE N0.
oQ
m3
�w
Ow
f LL
00
z'i
yw
y
ZoZo
QU
iG
�Q
0,
W
Cm
a
MD
W
Ln
Zow
W
U
goo
�w
NW
F0
0
VERSION
OR AFE NO.
SCALE: I0
ISO
4'
DESIGN TEAM
DATE
DGNR.
J. YOUST
W22-2015
PM./DP.
D. TIMMER
05-22.2015
RVR./DP.
B. BU7ARD
05.22.2015
DRWG. NO.
D-
4
Ol FINISH PLAN r
SCALE: 1/4" = 1'-0"
rLUUK ANU WALL HNlbHt5 & AUUL6bUKlt5 bUHtUULt
REF DESCRIPTION SIZE COLOR ORDER NO. GROUT
CT-X
CERAMIC FLOOR TILE
12"x12"
I EXISTING
---
---
ElCERAMIC
FLOOR TILE
12"02"
WHITE
CROSSVILLE
TO MATCH
CT-2X
CERAMIC FLOOR TILE
12"x12"
GRAY
CROSSVILLE
TO MATCH
CT-3X
CERAMIC FLOOR TILE
12"x12"
GREEN
CROSSVILLE
TO MATCH
ANTI -FATIGUE MAT
CUSTOM
GRAY
4489, 12K4 CUT
FM-1
A
I
VINYL COVE BASE
4"
MATCH EXISTING
---
FRP-1
Hl
WASHABLE FIBERGLASS
4'x8', x10% x12'
WHITE
REINF. POLYESTER PANELS
FRP-2
WASHABLE FIBERGLASS
4'x8', x10% x12'
LIGHT GREY
REINF. POLYESTER PANELS
CORNER GUARD
2"x2"x48" LENGTH
STAINLESS STEEL
CG-51-48
V-i
3M CONTROLTAC PLUS
SERIES 180C
GRAPHIC FILM
ARDEX K301 SELF -LEVELING CEMENT -BASED
T 1
TOPPING WITH 8+9 SEALER
FINISH NOTES
PLASTIC LAMINATE & CABINET FINISHES
SCHEDULE
6
6
REF
PROTO
DESCRIPTION
MFR
COLOR
ORDER #
FINISH SCHED NOTES
6
SS-1
V3900
1/2" STAINLESS STEEL
#D315-TM051
12,11
6
F-1
V3900
SOLID SURFACE
WILSONART
#1530-TM
12,11
7
F-2
V3900
PLASTIC LAMINATE
WILSONART
(MAROON)
#4662-60
12,11
2
F-3
V3900
PLASTIC LAMINATE
WILSONART
PEAR - MATTE NATURAL
#D7061-60
12,11
3,4
F-4
NOT USED.
3,4
F-5
V3900
PLASTIC LAMINATE
WILSONART
BLACK
#1595-60
12,11
8
F-6
V3900
PLASTIC LAMINATE
PIONITE
WINTER WHITE
#SW-836
CLASS "A"
F-7
V3900
PLASTIC LAMINATE
WHITE CABINET
LINER
NON -SLIP FINISH &
F-9
V3900
PLASTIC LAMINATE
A IONITE
FOLKSTONE GREY
#SG-241
CLEAR SEALER
FINISH PLAN NOTES: FINISH PLAN GENERAL NOTES:
1. PYISTnNG ri OOR TILE TO REMAIN, A. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIALS AND EQUIPMENT
2. NOT USED Q REQUIRED FOR A COMPLETE INSTALLATION PER ALL APPLICABLE CODES AND THESE
3 DRAWINGS, UNLESS OTHERWISE NOTED.
3. EXISTING VCT TO REMAIN. B. ALL EXISTING FLOORS, WALLS, OR OTHER SURFACES TO RECEIVE A FINISH MATERIAL md
4. NOT USED SHALL BE MADE SQUARE, LEVEL, AND PLUMB.
5. NOT USED C. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCING
6. NOT USED WORK, IF ANY DISCREPANCIES EXIST, CONTRACTOR SHALL NOTIFY PROJECT
7. NOT USED MANAGER IMMEDIATELY.
D. UNLESS NOTED OTHERWISE, ALL MATERIAL AND EQUIPMENT WILL BE FURNISHED AND
8. NEW ANTI -FATIGUE MAT. INSTALLED BY THE GENERAL CONTRACTOR. THIS NOTE APPLIES TO ALL DRAWINGS.
9. EXISTING SEALED CONCRETE TO REMAIN. E. NOT USED.
10. PAINT ALL EXPOSED GYPSUM BOARD. F. CONTRACTOR TO VERIFY WITH PROJECT MANAGER ALL WALLS, DOORS, AND FRAMES 7007 DISCOVERY BLVD
11. INSTALL STEEL CORNER GUARDS ON ALL OUTSIDE CORNERS, TYP. REFER TO TO BE PAINTED. DUBLIN, OH 43017
FLOOR AND WALL FINISHES & ACCESSORIES SCHEDULE G. ALL "SCHEDULE FINISH MATERIAL" AND THE CORRESPONDING "ROOM FINISH SCHEDULE 614.634.7000 T
12. NOT USED NOTES" MAY NOT APPLY TO THE SCOPE OF WORK. THE FINISH MATERIALS ARE SHOWN
13. NO WORK IN THIS AREA, FOR REFERENCE FOR ANY ADDITIONAL WORK THAT MAY BE REQUESTED OR REQUIRED WDPARTNERS.COM
14, PAINT ONLY AT DIRECTION OF PROJECT MANAGER. OUTSIDE THE SCOPE OF WORK.
15. PAINT EACH SIDE OF DOOR AND FRAME TO MATCH ADJACENT WALLS, NOTE THAT H. PREP & CLEAN ALL SURFACES BEFORE APPLYING NEW FINISHES.
EACH SIDE OF DOOR MAY DIFFER IN COLOR.
16. DO NOT PAINT BEHIND TAN GRAPHICS PANELS. TAPE EDGES AND PAINT PER PLAN. PLAN KEY PAINT SCHEDULE
�E OF•F�O
SEE FINISH PLAN Pt "SHERWIN-WILLIAMS" #EXTRA WHITE (WHITE) �� K. �O
CONSTRUCTION NOTES Q
P2 "SHERWIN-WILLIAMS" #SW2130 - PERMA WHITE •%• tN,'�
SEE SCHEDULES _: •
THIS SHEET P3 "SHERWIN-WILLIAMS" #7034 STATUS BRONZE
c):C)
AREA OF NEW SLAB AND CERAMIC TILE p4 "SHERWIN-WILLIAMS" #SW4056 - (TO MATCH ••,'��
�
PMS-249C'BLUE' - MFD BY BREAK THROU 3H) A,"" A G�
AREA OF NEW TILE PS "SHERWIN-WILLIAMS" #SW7031 -MEGA GRAIGE
ON EXISTING SLAB P6 " OCT B ®�. 2015
SHERWIN-WILLIAMS"#SW7029-AGREEABLE GRAY
ROOM FINISH SCHEDULE NOTES: ° P7 "SHERWIN-WILLIAMS" #SW6105 DIVINE WHITE
1. ALL FLOOR & WALL TILE WILL BE MANUFACTURED BY CROSSVILLE.
2. 4" VINYL COVE BASE MANUFACTURED BY ROPPE CO. a
0)
3. FIBERGLASS REINFORCED POLYESTER (FRP) PANELS ARE CLASS A MATERIAL, MANUFACTURED BY MARLITE OR NUDO PRODUCTS.
CONTRACTOR TO PLACE ORDER BY CONTACTING: 0
MARLITE (ORDER FRF FRP-1: #P-100, COLOR=WHITE & FRP-2: #P-151, COLOR=LIGHT GREY) Ti{� (~L,R7\I5 Alp ALL PRQPOsJfl WORK0
COVER, T: (3 0) 34 ARE SUBJECT TO ANY COWECT.Ot9S -
CONTACT: (330) 343-6621 �
OR REOUIRM BY FIELD fNSPECX RS THAT N
NUDO PRODUCTS (ORDER FIBER-LITE .090 LINER #LP-F9, FRP-1: COLOR WHITE 050 �qY �.�EC SAAY IN TO U0
& FRP-2: COLOR LIGHT GREY 750) BE1500 TAYLOR AVE C if •LY Ul T H ALL .��tAJL.ICAr�' .E CODES.
SPRINGFIELD, ILLINOIS 62703 m M
CONTACT: MARK SIMPSON (800) 826-4132 bA�
T 0
4. CONTRACTOR SHALL PROVIDE NECESSARY TRIMS, CLOSURES AND ACCESSORIES FOR A FINISHED INSTALLATION. m @ y =
n � 0 O
�
5. FLOOR GROUT TO BE PROVIDED BY: 20Cc y •yp O
CUSTOM BUILDING PRODUCTS a In W W
13001 SEAL BEACH DRIVE
SANTA MONICA, CA 90740 I L
PHONE: 562-598-8808
6. GROUT TO MATCH EXISTING.
EEO U U ly
7. ANTI -FATIGUE MAT SHALL BE WEARWELL "ERGO -STANCE" #489 AS MANUFACTURED BY:
TENNESEE MAT COMPANY, INC.
1414 FOURTH AVENUE SOUTH
NASHVILLE, TN 37210
PHONE: 800-264-3030
MAT DIMENSION IS CUSTOM WIDTH WHICH MUST BE END -TRIMMED TO MEET BOUNDARY OF TILE. MATS SHALL BE FITTED SO AS TO PROVIDE FULL COVERAGE OF a
ATTENDANT AREA WITH MAT -TO -TILE JUNCTION BUTTED TIGHTLY AND FIRMLY ADHERED, SO AS TO PREVENT A TRIPPING HAZZARD.
8. CORNER GUARD FURNISHED AND INSTALLED BY CONTRACTOR PER MANUFACTURS INSTRUCTIONS. PLACE ORDER BY CONTRACTING PAWLING CORPORATION PHONE (914) K+ _9oa
373-8712. INSTALL ON ALL OUTSIDE CORNERS. .o $ �o
S w
9. ALL FLOOR TILE GROUT SHALL BE SEALED WITH AQUA MIX GROUT SEALER. (800) 366-6877. SEALANT SHALL BE APPLIED TO THE GROUT ONLY. FLOOR TILE NOT TO BE oN
SEALED.
10. INSTALL ALUMINUM TRANSITION EDGE AT DOOR OPENINGS. EDGE IS MODEL TRANZ 1132 BY CERAMIC TOOL COMPANY, INC.
U
11. INTERIOR LAMINATED WINDOWSILLS PROVIDED BY CABINET VENDOR INSTALLED BY CONTRACTOR. LAMINATE MANUFACTURED BY WILSONART. � <w
12. CABINET FINISH: MATERIAL MANUFACTURED BY WILSONART. L) w�
CABINETS TO BE FABRICATED & SUPPLIED BY CABINET VENDOR, a yw
CABINETS FINISHES MAY ONLY APPEAR ON CABINET DRAWINGS AS PREPARED BY CABINET VENDOR. w oy
x
W
13. CONTRACTOR SHALL FURNISH AND INSTALL AN ELASTORMERIC ANT -FRACTURE MEMBRANE OVER ALL CONTROL JOINTS AND SHRINKAGE CRACKS ON ALL AREAS RECEIVING N 3 w
CERAMIC FLOOR TILE. AVAILABLE PRODUCTS INCLUDE: p NMD
LEVEL QUIK WATERPROOFING & ANTIFRACTURE MEMBRANE O a
Z xC
CUSTOM BUILDING PRODUCTS ¢ w
PHONE: 800-272-8786
OR o zo
HYDROMENT ULTRA -SET CRACK ISOLATION MEMBRANE ¢ a$
BOSTIK FLOORING z oy
PHONE: 800-726-7845 z s
W �o
14. PROVIDE NEW TILE WHERE TILE WAS REMOVED DUE TO DEMOLITION.
15. NOT USED REVISION o
z 14 m
ROOM FINISH SCHEDULE
ROOM I I FLOOR BASE WALLS CEILING
SALES AREA
'�■■■ I-�'®■-■■■
ATTENDANT AREA
MIME MIMEMIllMMM
�v
QP � <P 0 .G O °C•
5
O
° REMARKS
SEE ROOM FINISH SCHEDULE NOTES #7
FLOOR IS VCT. FINISH RM AT DISCRETION OF PM
FLOOR IS VCT. FINISH RM AT DISCRETION OF PM
FINISH ROOM AT DISCRETION OF PM
PAINT CEILING AND TOP 12" OF WALL P4.
w
E
N
�
Z
10
O-zt
Q
L u
0 J
0
U
LL
Q
Lu
-
�
J
Z
S2
U)
LL
Z
�
LL
CD d
06
(.0
NOR 6485
AFE NO.
\LE:
TEAM DATE
J. YOUST 0&22.2015
D. TIMMER 05-22.2015
'. B. BUZARD 05-22.2015
NO. A-3