Loading...
HomeMy WebLinkAboutREVISION 10-29-15.4 - n J 01 MEN 1. 4 s HALL UTILITY 17 23 35 6 4 8 17 4 17 28 0 EIF 23 o I WOMEN 9M, ' 4 9 17 23 35 uL- STORAGE KIM J 4 9 17 23 �lol� _ r I r j2HEATq� II I n r I I I I I I I 9ERVENb I II u LJ-� L__J LDJ LJ II I y_ -�- _- � ATTENDANT J I ffri r 1 1 4 17 TYP I 28 El STORAGE 4 9 17 35 I I I O a 2.0 cc 5 6 5 6 \ \ / \ II II I --�.�---_-_JL_--JL__-_J z7 5 6 3 I II II II I I I I II II II I I I � 37 � // / 5 6 \> 2 SALES uwWl AREA / 4 17 28 � 38 - - - - - - - - - - - I L_ FLOOR DEMOLITION PLAN SCALE: 1/4" = 1'-0" 6 6 0 r- nr WALK4N COOLER ffm 'ALK-IN 1 IE�E--ZER Oar J FLOOR DEMOLITION PLAN NOTES: 1. EQUIPMENT / FURNITURE TO REMAIN. COORDINATE ANY REPAIRS WITH PROJECT MANAGER, 2. EQUIPMENT / FURNITURE TO BE REMOVED AND STORED IN A SAFE PLACE TO BE REINSTALLED IN NEW LOCATION PER REMODEL PLANS. COORDINATE WORK WITH PROJECT MANAGER. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND INSTALLATION OF EQUIPMENT PER PLANS AND INSTRUCTIONS OF PROJECT MANAGER. REMOVE ALL PLUMBING AND ELECTRICAL ASSOCIATED WITH EQUIPMENT BACK TO SOURCE UNLESS OTHERWISE NOTED ON PLUMBING AND ELECTRICAL DRAWINGS. 3. EQUIPMENT / FURNITURE TO BE REMOVED. COORDINATE WORK WITH PROJECT MANAGER. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF EQUIPMENT UNLESS OTHERWISE INSTRUCTED BY PROJECT MANAGER. REMOVE ALL PLUMBING AND ELECTRICAL ASSOCIATED WITH EQUIPMENT BACK TO SOURCE UNLESS OTHERWISE NOTED ON PLUMBING AND ELECTRICAL DRAWINGS, 4. WALL(S) / PARTITION(S) TO REMAIN. REFER TO FLOOR PLAN FOR EXTENT OF NEW WORK REQUIRED ON EXISTING WALL. FINISH MATERIALS TO REMAIN UNLESS OTHERWISE NOTED. REFER TO FINISH PLAN. 5. PROJECT MANAGER AND CONTRACTOR SHALL COORDINATE WITH MARKETING DEPARTMENT FIELD MERCHANDISER FOR REMOVAL OF EXISTING GONDOLA EQUIPMENT. 6. REMOVE MERCHANDISING AND STORAGE RACKS, AND/OR SHELVING. COORDINATE WITH PROJECT MANAGER FOR REUSE OF SHELVING AND STORAGE OF MERCHANDISE. GONDOLA SHELVING RELOCATION MAY ALREADY BE COMPLETED BY OTHERS BEFORE REMODEL. VERIFY AT BID WALK. 7. NOT USED 8. NOT USED 9. EXISTING EQUIPMENT AND FURNITURE TO REMAIN AS IS. 10. REMOVE WALL FINISHES, GRAPHICS, AND APPLICATIONS TO ALLOW FOR INSTALLATION OF NEW CABINETRY AND/OR MERCHANDISING EQUIPMENT, INSTALL STRAIGHT AND PLUMB. REFER TO FINISH PLAN. COORDINATE WITH PROJECT MANAGER. 11. REMOVE WALL / PARTITION. REMOVE ACCESSIBLE GAS, PLUMBING, ELECTRICAL, AND TELEPHONE FEEDERS PER ELECTRICAL DEMOLITION PLAN. CAP ALL INACCESSIBLE UTILITIES PER APPLICABLE CODES AND INDUSTRY STANDARDS. 12. REMOVE COOLER PANELS AND COOLER DOORS AS NEEDED FOR NEW COOLER LAYOUT. 13. REMOVE FREEZER DOOR. 14. NOT USED 15. NOT USED 16. NOT USED 17. EXISTING FLOOR TILE TO REMAIN. 18. EXISTING SIDEWALK TO REMAIN. 10 MOT I ICGIj 20. NOT USED Q3 21. Ivdl uS1=b 22. REFER TO MPE DRAWINGS FOR EXTENT OF MECHANICAL, PLUMBING, AND ELECTRICAL DEMOLITION. 23• EXISTING PLUMBING FIXTURES TO REMAIN. 24. NOT USED 25. NOT USED 26. NOT USED 27. REMOVE EXISTING EVAPORATOR FOR RELOCATION. DISCONNECT POWER AND REFRIGERANT PIPING. REFER TO MECHANICAL SHEETS. 28. EXISTING CAMERAS AND SPEAKERS TO REMAIN. 29. NOT USED 30. EXISTING ELECTRICAL EQUIPMENT TO REMAIN. 31. NOT USED 32. REMOVE EXISTING COOLER DOORS AND 5-DOOR FRAME. STORE THE FOUR BEST COOLER DOORS FOR REUSE. 33. NOT USED 34. NOT USED 35. NO DEMOLITION IN THIS AREA. 36. EXISTING CANOPY TO REMAIN. 37. EXISTING COOLER/FREEZER EVAPORATORS TO REMAIN. 38. REMOVE METAL COLUMN COVERS AND ACCESSORIES. 39. NOT USED 40. NOT USED FLOOR DEMOLITION LEGEND O SEE DEMOLITION PLAN NOTES - _ - EXISTING WALLS, EQUIPMENT, - FURNITURE, & ETC. TO BE REMOVED EXISTING WALLS, EQUIPMENT, F- - I APPROXIMATE LOCATION OF FURNITURE, &ETC. TO REMAIN L _ J CONCRETE SLAB SAW CUTS THESE PLANS AND ALL PROPOSED t"JORf ARE SUBJECT TO ANY COMECT;ONS REQUIRED BY FIELD INSPECXRS THAT MAY BE NECMSAS1Y IN Of4MM TO GO;:;r LY U;1TH ALL A?PLIGAiZIE CODES. FLOOR DEMOLITION GENERAL NOTES: A. THESE DRAWINGS DO NOT INDICATE THE FULL EXTENT OF THE WORK DETAILS REQUIRED TO COMPLETE THIS REMODEL PROJECT. VERIFY EXISTING CONDITIONS FOR THE FULL EXTENT OF THE WORK REQUIRED TO COMPLETE THIS PROJECT IN A WORKMANLIKE MANNER PER ALL APPLICABLE CODES AND THESE DRAWINGS. COORDINATE WORK WITH THE PROJECT MANAGER. B. DEMOLISH EXISTING CONSTRUCTION ONLY TO THE EXTENT NECESSARY TO COMPLETE THE NEW CONSTRUCTION. CUT BACK EXISTING FINISHED SURFACES TO SQUARE, LEVEL, AND PLUMB LINES. C. CAREFULLY REVIEW PLANS AND DETERMINE UTILITIES THAT ARE REQUIRED TO BE DISCONNECTED AND THOSE THAT WILL REMAIN FUNCTIONAL. COORDINATE WORK WITH THE APPROPRIATE UTILITY PROVIDER. SCHEDULE WORK FOR A MINIMUM OF INTERRUPTION, D. REMOVE AND SECURE ALL GAS, PLUMBING, ELECTRICAL, AND OTHER UTILITIES ASSOCIATED WITH EQUIPMENT REMOVED FROM SITE. INSTALL REQUIRED MATERIALS TO SECURE AND MAKE SAFE ALL UTILITIES TO REMAIN. E. PREVENT PUBLIC ACCESS TO THE WORK AREA. INSTALL BARRIERS AND SIGNAGE TO ALERT THE GENERAL PUBLIC, EMPLOYEES, AND CONTRACTORS OF DANGERS. F. GENERAL CONTRACTOR SHALL PROTECT ALL EQUIPMENT THAT WILL REMAIN FOLLOWING REMODEL BY PLACING IT IN STORAGE FOR THE DURATION OF THE PROJECT. COORDINATE WITH THE PROJECT MANAGER. G. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING WORK PERMITS AND COMMUNICATING WITH UTILITY PROVIDER(S) PRIOR TO ANY WORK AFFECTING SERVICES. FIELD VERIFY LOCATION OF ALL SERVICES. H. CONTRACTOR SHALL VERIFY w/ PROJECT MANAGER ALL EQUIPMENT & FURNITURE TO BE REMOVED AND RELOCATED PRIOR TO COMMENCING WITH THE WORK. I. ANY WALLS BEING PROPOSED FOR REMOVAL SHALL BE CONFIRMED BY THE CONTRACTOR AS BEING NON -LOAD BEARING BEFORE PROCEEDING WITH REMOVAL. IF LOAD -BEARING WALLS) ARE FOUND DUE TO UNFORESEEN CONDITIONS, IT SHOULD BE BROUGHT DIRECTLY TO THE PROJECT MANAGER'S ATTENTION BEFORE PROCEEDING WITH THE REMOVAL OF THAT WALL. NOTE: THE ARCHITECT HAS MADE ASSUMPTIONS BASED ON PREVIOUS DRAWINGS AND THE EXISTING CONDITIONS THAT ARE VIEWABLE. HE HAS USED HIS BEST JUDGMENT TO DETERMINE ALL LOAD -BEARING WALLS. FILE COPY 0 O N I M 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634,7000 T WDPARTNERS.COM K. OCT 21 2W a 0 0 0 U 3 N 0 0 U M Mm np TCO mf6y= a-p yO �yc� aa)uo a :%i Lu W =N O H U.) O J co Z Q C I W Lu JQ 2 O _� 1 (00 Dom.. ILL. STORE OR 6485 BIDE N0. oQ m3 �w Ow f LL 00 z'i yw y ZoZo QU iG �Q 0, W Cm a MD W Ln Zow W U goo �w NW F0 0 VERSION OR AFE NO. SCALE: I0 ISO 4' DESIGN TEAM DATE DGNR. J. YOUST W22-2015 PM./DP. D. TIMMER 05-22.2015 RVR./DP. B. BU7ARD 05.22.2015 DRWG. NO. D- 4 Ol FINISH PLAN r SCALE: 1/4" = 1'-0" rLUUK ANU WALL HNlbHt5 & AUUL6bUKlt5 bUHtUULt REF DESCRIPTION SIZE COLOR ORDER NO. GROUT CT-X CERAMIC FLOOR TILE 12"x12" I EXISTING --- --- ElCERAMIC FLOOR TILE 12"02" WHITE CROSSVILLE TO MATCH CT-2X CERAMIC FLOOR TILE 12"x12" GRAY CROSSVILLE TO MATCH CT-3X CERAMIC FLOOR TILE 12"x12" GREEN CROSSVILLE TO MATCH ANTI -FATIGUE MAT CUSTOM GRAY 4489, 12K4 CUT FM-1 A I VINYL COVE BASE 4" MATCH EXISTING --- FRP-1 Hl WASHABLE FIBERGLASS 4'x8', x10% x12' WHITE REINF. POLYESTER PANELS FRP-2 WASHABLE FIBERGLASS 4'x8', x10% x12' LIGHT GREY REINF. POLYESTER PANELS CORNER GUARD 2"x2"x48" LENGTH STAINLESS STEEL CG-51-48 V-i 3M CONTROLTAC PLUS SERIES 180C GRAPHIC FILM ARDEX K301 SELF -LEVELING CEMENT -BASED T 1 TOPPING WITH 8+9 SEALER FINISH NOTES PLASTIC LAMINATE & CABINET FINISHES SCHEDULE 6 6 REF PROTO DESCRIPTION MFR COLOR ORDER # FINISH SCHED NOTES 6 SS-1 V3900 1/2" STAINLESS STEEL #D315-TM051 12,11 6 F-1 V3900 SOLID SURFACE WILSONART #1530-TM 12,11 7 F-2 V3900 PLASTIC LAMINATE WILSONART (MAROON) #4662-60 12,11 2 F-3 V3900 PLASTIC LAMINATE WILSONART PEAR - MATTE NATURAL #D7061-60 12,11 3,4 F-4 NOT USED. 3,4 F-5 V3900 PLASTIC LAMINATE WILSONART BLACK #1595-60 12,11 8 F-6 V3900 PLASTIC LAMINATE PIONITE WINTER WHITE #SW-836 CLASS "A" F-7 V3900 PLASTIC LAMINATE WHITE CABINET LINER NON -SLIP FINISH & F-9 V3900 PLASTIC LAMINATE A IONITE FOLKSTONE GREY #SG-241 CLEAR SEALER FINISH PLAN NOTES: FINISH PLAN GENERAL NOTES: 1. PYISTnNG ri OOR TILE TO REMAIN, A. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIALS AND EQUIPMENT 2. NOT USED Q REQUIRED FOR A COMPLETE INSTALLATION PER ALL APPLICABLE CODES AND THESE 3 DRAWINGS, UNLESS OTHERWISE NOTED. 3. EXISTING VCT TO REMAIN. B. ALL EXISTING FLOORS, WALLS, OR OTHER SURFACES TO RECEIVE A FINISH MATERIAL md 4. NOT USED SHALL BE MADE SQUARE, LEVEL, AND PLUMB. 5. NOT USED C. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCING 6. NOT USED WORK, IF ANY DISCREPANCIES EXIST, CONTRACTOR SHALL NOTIFY PROJECT 7. NOT USED MANAGER IMMEDIATELY. D. UNLESS NOTED OTHERWISE, ALL MATERIAL AND EQUIPMENT WILL BE FURNISHED AND 8. NEW ANTI -FATIGUE MAT. INSTALLED BY THE GENERAL CONTRACTOR. THIS NOTE APPLIES TO ALL DRAWINGS. 9. EXISTING SEALED CONCRETE TO REMAIN. E. NOT USED. 10. PAINT ALL EXPOSED GYPSUM BOARD. F. CONTRACTOR TO VERIFY WITH PROJECT MANAGER ALL WALLS, DOORS, AND FRAMES 7007 DISCOVERY BLVD 11. INSTALL STEEL CORNER GUARDS ON ALL OUTSIDE CORNERS, TYP. REFER TO TO BE PAINTED. DUBLIN, OH 43017 FLOOR AND WALL FINISHES & ACCESSORIES SCHEDULE G. ALL "SCHEDULE FINISH MATERIAL" AND THE CORRESPONDING "ROOM FINISH SCHEDULE 614.634.7000 T 12. NOT USED NOTES" MAY NOT APPLY TO THE SCOPE OF WORK. THE FINISH MATERIALS ARE SHOWN 13. NO WORK IN THIS AREA, FOR REFERENCE FOR ANY ADDITIONAL WORK THAT MAY BE REQUESTED OR REQUIRED WDPARTNERS.COM 14, PAINT ONLY AT DIRECTION OF PROJECT MANAGER. OUTSIDE THE SCOPE OF WORK. 15. PAINT EACH SIDE OF DOOR AND FRAME TO MATCH ADJACENT WALLS, NOTE THAT H. PREP & CLEAN ALL SURFACES BEFORE APPLYING NEW FINISHES. EACH SIDE OF DOOR MAY DIFFER IN COLOR. 16. DO NOT PAINT BEHIND TAN GRAPHICS PANELS. TAPE EDGES AND PAINT PER PLAN. PLAN KEY PAINT SCHEDULE �E OF•F�O SEE FINISH PLAN Pt "SHERWIN-WILLIAMS" #EXTRA WHITE (WHITE) �� K. �O CONSTRUCTION NOTES Q P2 "SHERWIN-WILLIAMS" #SW2130 - PERMA WHITE •%• tN,'� SEE SCHEDULES _: • THIS SHEET P3 "SHERWIN-WILLIAMS" #7034 STATUS BRONZE c):C) AREA OF NEW SLAB AND CERAMIC TILE p4 "SHERWIN-WILLIAMS" #SW4056 - (TO MATCH ••,'�� � PMS-249C'BLUE' - MFD BY BREAK THROU 3H) A,"" A G� AREA OF NEW TILE PS "SHERWIN-WILLIAMS" #SW7031 -MEGA GRAIGE ON EXISTING SLAB P6 " OCT B ®�. 2015 SHERWIN-WILLIAMS"#SW7029-AGREEABLE GRAY ROOM FINISH SCHEDULE NOTES: ° P7 "SHERWIN-WILLIAMS" #SW6105 DIVINE WHITE 1. ALL FLOOR & WALL TILE WILL BE MANUFACTURED BY CROSSVILLE. 2. 4" VINYL COVE BASE MANUFACTURED BY ROPPE CO. a 0) 3. FIBERGLASS REINFORCED POLYESTER (FRP) PANELS ARE CLASS A MATERIAL, MANUFACTURED BY MARLITE OR NUDO PRODUCTS. CONTRACTOR TO PLACE ORDER BY CONTACTING: 0 MARLITE (ORDER FRF FRP-1: #P-100, COLOR=WHITE & FRP-2: #P-151, COLOR=LIGHT GREY) Ti{� (~L,R7\I5 Alp ALL PRQPOsJfl WORK0 COVER, T: (3 0) 34 ARE SUBJECT TO ANY COWECT.Ot9S - CONTACT: (330) 343-6621 � OR REOUIRM BY FIELD fNSPECX RS THAT N NUDO PRODUCTS (ORDER FIBER-LITE .090 LINER #LP-F9, FRP-1: COLOR WHITE 050 �qY �.�EC SAAY IN TO U0 & FRP-2: COLOR LIGHT GREY 750) BE1500 TAYLOR AVE C if •LY Ul T H ALL .��tAJL.ICAr�' .E CODES. SPRINGFIELD, ILLINOIS 62703 m M CONTACT: MARK SIMPSON (800) 826-4132 bA� T 0 4. CONTRACTOR SHALL PROVIDE NECESSARY TRIMS, CLOSURES AND ACCESSORIES FOR A FINISHED INSTALLATION. m @ y = n � 0 O � 5. FLOOR GROUT TO BE PROVIDED BY: 20Cc y •yp O CUSTOM BUILDING PRODUCTS a In W W 13001 SEAL BEACH DRIVE SANTA MONICA, CA 90740 I L PHONE: 562-598-8808 6. GROUT TO MATCH EXISTING. EEO U U ly­ 7. ANTI -FATIGUE MAT SHALL BE WEARWELL "ERGO -STANCE" #489 AS MANUFACTURED BY: TENNESEE MAT COMPANY, INC. 1414 FOURTH AVENUE SOUTH NASHVILLE, TN 37210 PHONE: 800-264-3030 MAT DIMENSION IS CUSTOM WIDTH WHICH MUST BE END -TRIMMED TO MEET BOUNDARY OF TILE. MATS SHALL BE FITTED SO AS TO PROVIDE FULL COVERAGE OF a ATTENDANT AREA WITH MAT -TO -TILE JUNCTION BUTTED TIGHTLY AND FIRMLY ADHERED, SO AS TO PREVENT A TRIPPING HAZZARD. 8. CORNER GUARD FURNISHED AND INSTALLED BY CONTRACTOR PER MANUFACTURS INSTRUCTIONS. PLACE ORDER BY CONTRACTING PAWLING CORPORATION PHONE (914) K+ _9oa 373-8712. INSTALL ON ALL OUTSIDE CORNERS. .o $ �o S w 9. ALL FLOOR TILE GROUT SHALL BE SEALED WITH AQUA MIX GROUT SEALER. (800) 366-6877. SEALANT SHALL BE APPLIED TO THE GROUT ONLY. FLOOR TILE NOT TO BE oN SEALED. 10. INSTALL ALUMINUM TRANSITION EDGE AT DOOR OPENINGS. EDGE IS MODEL TRANZ 1132 BY CERAMIC TOOL COMPANY, INC. U 11. INTERIOR LAMINATED WINDOWSILLS PROVIDED BY CABINET VENDOR INSTALLED BY CONTRACTOR. LAMINATE MANUFACTURED BY WILSONART. � <w 12. CABINET FINISH: MATERIAL MANUFACTURED BY WILSONART. L) w� CABINETS TO BE FABRICATED & SUPPLIED BY CABINET VENDOR, a yw CABINETS FINISHES MAY ONLY APPEAR ON CABINET DRAWINGS AS PREPARED BY CABINET VENDOR. w oy x W 13. CONTRACTOR SHALL FURNISH AND INSTALL AN ELASTORMERIC ANT -FRACTURE MEMBRANE OVER ALL CONTROL JOINTS AND SHRINKAGE CRACKS ON ALL AREAS RECEIVING N 3 w CERAMIC FLOOR TILE. AVAILABLE PRODUCTS INCLUDE: p NMD LEVEL QUIK WATERPROOFING & ANTIFRACTURE MEMBRANE O a Z xC CUSTOM BUILDING PRODUCTS ¢ w PHONE: 800-272-8786 OR o zo HYDROMENT ULTRA -SET CRACK ISOLATION MEMBRANE ¢ a$ BOSTIK FLOORING z oy PHONE: 800-726-7845 z s W �o 14. PROVIDE NEW TILE WHERE TILE WAS REMOVED DUE TO DEMOLITION. 15. NOT USED REVISION o z 14 m ROOM FINISH SCHEDULE ROOM I I FLOOR BASE WALLS CEILING SALES AREA '�■■■ I-�'®■-■■■ ATTENDANT AREA MIME MIMEMIllMMM �v QP � <P 0 .G O °C• 5 O ° REMARKS SEE ROOM FINISH SCHEDULE NOTES #7 FLOOR IS VCT. FINISH RM AT DISCRETION OF PM FLOOR IS VCT. FINISH RM AT DISCRETION OF PM FINISH ROOM AT DISCRETION OF PM PAINT CEILING AND TOP 12" OF WALL P4. w E N � Z 10 O-zt Q L u 0 J 0 U LL Q Lu - � J Z S2 U) LL Z � LL CD d 06 (.0 NOR 6485 AFE NO. \LE: TEAM DATE J. YOUST 0&22.2015 D. TIMMER 05-22.2015 '. B. BUZARD 05-22.2015 NO. A-3