HomeMy WebLinkAboutENGINEERINGc GENERAL NOTES 1. DESIGN CRITERIA: SCANNED APPLICABLE CODES, REGULATIONS & STANDARDS: �� 1. THE 2017 FLORIDA BUILDING CODE, 6TH EDITION SPECIF CALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23 WOOD. 2. ASCE 7-10. & SEI7 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. AC1318 CONCRETE REFRENCE MANUAL. 5. PCI PRECAST & PRESTRESSED CONCRETE. 6. AA ASM 35 & AA ADM 1 WIND LOADS: 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. SCREENED ROOF ENCLOSURE FBC 2017 CH. 20 TABLE 2002.4 CONCRETE & FOUNDATION DESIGN: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: A. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 - ASTM C 150 11. AGGREGATES - LARGE AGGREGATE 3/4" MAX. - ASTM C 33 III. AIR ENTRAINING +/- 1 % - ASTM C 260 IV. WATER REDUCING AGENT - ASTM C 494 V. CLEAN POTABLE WATER VI. OTHER ADMIXTURES NOT PERMITTED B. METAL ACCESSORIES SHALL CONFORM TO: ALUMINUM SPECIFICATIONS: 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE SPECIFIED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 .SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. FASTNER SPECIFICATIONS: 1. FASTNERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG.) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, AND FASTENERS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4"X3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1 "X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4"X2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14X2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10X1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE VX2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS: lobs-o43c ST. LL1C.rE COLNTV RUILL�T''� c REVIEWED FOcZ COI�LL E RE,,VIE'" ED BY DATE PLANS AND PERMIT MUST B KEPT OR NO WSPECTION WILL B , MADE. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND INSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. I. REINFORCING BARS - ASTM A615, GRADE 60 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD 11. WELDED WIRE FABRIC - ASTM A185 HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" ON TYPE M OR S MORTAR. OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT 2. ALL MORTAR SHALL BE TYPE M OR S. PERMITTED. 3. ALL GROUT-SJ=IALLBE2000_P_SLMINIMU.M-ANlD-HAVE _ -D-PREPARE & PLACE -CONCRETE -PER AMERrc-WCONCRETE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING INCLUDING HOT WHEATHER RECOMMENDATIONS. REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN E. MOIST CURE OR POLYETHYLENE CURING PERMITTED. HEIGHT. F. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE MISCELLANEOUS: FBC. (CATEGORY 2 ROOMS ONLY) 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL G. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC BARRIER. (CATEGORY 2 ROOMS ONLY) R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. FOOTING SIZE: EXISTING CONCRETE SLAB. NO ADDITIONAL 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH SLAB (3000 PSI) IS PROVIDED IN SOUND CONDITION, FREE WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO FROM STRUCTURAL CRACKING, SPALLING & OTHER ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE THE FIELD. VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI 3. WHEN APPLICABLE FOR ATTACHING NEW FOOTER TO EXISTING, GROUT WITH BONDING AGENT. DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED (OR EQUAL) TYP. ALL LOCATIONS. STRUCTURE. 4. WHEN INSTALLING 4" CONCRETE SLAB -ADD ADJACENT TO 6. ALL 2X4 & GREATER ARE TO BE SMB UNLESS OTHERWISE INDICATED. EXISTING-DOWELL INTO EXISTING CONCRETE 48" O/C W/8" #5 REBARS- DRILL 3/4" HOLE 4" EMBEDMENT- EPDXY W/ RESPONSIBILITIES: NON -SHRINKING "SIMPSON EPDXY TIE" (OR EQUAL). 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHER WISE CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING NOTED. CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. LEGEND: (ALL MAY NOT APPL SCR = SCREEN KP = KICK PLATE PW = PICTURE WINDOW X = HORIZ. SLIDING WINDOW O = HORIZ. STATIONARY WINDOW DH = DOUBLE HUNG WINDOW SH= SINGLE HUNG WINDOW SIP = SOLID INSULATED PAN0CF.ALED F STENERS OR ATTACHMENTS CT = CABLE TIE SG = SUPER GUTTER ARE THE f ESFONSIBILITY OF THE CS = CLEAR SPAN COJ�IT ACTOR OF KB = KNEE BRACE RF GORD HOLLOW SECTIONS 2 x 2: 2"x2"x0.044" 2 x 3: 2"x3"x0.044" THESE PLANS j IIND ALL PROPOSED WORK 2 x 4: 2"x4"4.044" ARE SUBJECT TO ANY CORRECTIONS 2 x 5: 2"x5"x0.050" REQUIRED BY f IELD INSPECTORS THAT OPEN BACK SECTIONS MAY ®E NECKS IARY IN ORDER TO 1 x 2: 1 "x2"x0.044" GOMPhY WITH PAR Li GGDES. 1 x 3: 1 "x3"x0.044"-- . __-,PPW SNAP SECTIONS 2 x 2 SNAP: 2"x2"x0.050" 2 x 3 SNAP: 2"x3"x0.050" 2 x 4 SNAP: 2"x4"x0.045" SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044"x0.100" 2 x 5 SMB: 2"x5"x0.050"x0.100" 2 x 6 SMB: 2"x6"x0.050"x0.120" 2 x 7 SMB: 2"x7"x0.057"x0.120" 2 x 8 SMB: 2"x8"x0.072"x0.124" 2 x 9 SMB: 2"x9"x0.082"x0.124" 2 x 10 SMB: 2"x10"x0.092"x0.398" NOTE: AS INDICATED ABOVE MEMBER PROFILES ARE INDIffl. I "' a mpv, IN INCHES. L _ __ _ , U d.. m zz J Ill z_� V z� LLJ Q Q OLo J "T LL. It C) co 00 co co ap U p U � cm Lo 'L � N co c 2 � U a. N 00 t- 0 w U U rn 0 00 T_ DESIGN DATE: 5/4/2018 REVISION 1: DATE GE: REVISION 2: DATE I� SCALE: NTS I G WALL HEIGHT PER PLAA o;0 3m �l 00 0 m I x I \ m I > I I \ v I A I I \\ Fn m I N �3'-0" 3X2 2X5SM N X X - W W 2X5SM B v O 2X5SM B X X w O 2X5SM B N N v co w 0 2X5SM B 2X3 DJ 1 2X3 DJ 1X3 N 8 -01 10'-511 cn ;u x v CONTRACTOR: m Fn U5 cn 5 KRUGER CONSTRUCTION z z v CORP. N � � m Z —Di PROJECT ADDRESS: m m a, o LEITHER 9400 PINEBARK CT N m FORT PIERCE, FL a HO w X N N X W 1X3 2X3 i ......... w 1X3 HOST 24" O/H STRUC. GUTTER 8' HEIGHT 3X2 N w 2X6SMB N X co 2X6SMB ; O I � I XN ;O w i\ 2 07 I 2X6SMB c n 1 G) q I � m I 2X6SM6 0 cn i= I m I _ O w I X i� w I -------L----- 3X2----1------------. 24" O/H STRUC. GUTTER 8' HEIGHT 21'-011 eGENg �cr0 No'. 60102 ' FLORIDA ENGINEERING LLC 4456 TAM IAM I TRAIL, UNIT B 14STATE OF :0.� PORT CHARLOTTE, FLORIDA 33980 (941) 391-5980 www.fiengineeringlic.com UA g E. Gun on, P.E. #60102 PROJECT NO. 1811019 CA CERT. #30782E: 5/3/2018 r SELF -MATING OR 1/8"x2"x2"x3" ANGLE -_.SNAP SECTION TYP. 1/8"x2"x2" ANGLE 2 - #12 SMS INTO COLUMN z I'W" O.B. BASE PLATE-TYP. 0 0 2-1/4" x l/4" MASONRY ANCHOR 3/8" x 4" TAPCON 1-Y4" MIN. CONC. - o ANCHOR EMBEDMENT MIN 4" SLAB 3000 PSI 2" MIN. INCREASE DISTANCE CONC. w/FIBERMESH WHEN GREATER THAN 2x4 UPRIGHT IS USED CONC. FOOTING BELOW SIDE VIEW NOTE WHERE PAVERS ARE PRESENT USE 5/16" TAPCON XL (RED HEAD MFG.) MASONRY ANCHORS TO PENETRATE UNDERLYING CONCRETE FOOTING 2-1/4" (MIN.) BEAM 2 - #12 SMS INSTALL BF 3/8" x 4" TAPCON 2 @ SLAB (BEYOND) TO CORNE' 2-1/4" X 1/4" TAPCON 2 @ 1x3 BASE NOTE' BR/ HAVE 2" TC FROM COR 1"x3" BASE PLATE ANCHORED ........ TO CONCw/ 1/4" MASONRY ANCHOR 6" MAX EACH SIDE OF POST AND 24" O.C. MAX CONC. FOOTING BELOW FRONT VIEW DETAIL "B" - 2"x4" OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: NTS 2x2X3 ANGLE (3)-#.14 TEKS EACH SIDE 2x2x125 ANGLE W/ (4) #14x3/4" TEKS EACH SIDE 'HORIZONTAL OR SLOPED 2x2xl/8 ANGLE EAVE RAIL TO POST W/ (6) #14 EA. CLIP 0 0 0 0 0 BEAM PER PLAN NOTCHED TO RECEIVE COLUMN WITHIN 2X2X.125 ANGLE W/ (4) #14 TEKS COLUMN PER PLANS DETAIL E - UPRIGHT TO BEAM CONNECTION SCALE: NTS 2x2x 125 ANGLE W/ (2) #10 SMS INTO COL. & 3/8" x 2" TAPCON THRU 13ASEPLATEINTO CONCRETE 1-112" (MIN.) EMBEDMENT\ DETAIL "D" - ROOF BRACING CONNECTION DETAIL SCALE: NTS FASTEN TOP OF HEADER TO INTERSECTING 2"x3" MEMBER w/(2) #10 SMS w/l" PENETRATION INTO SCREW BOSS OF 2'W" MEMBER - TYP. BOTH SIDES 2"53" DOOR JAMB WHEN Z-BAR IS USED - FASTEN Z-BAR TO COL/HEADER AT EACH CORNER AND 18" O/C ALTERNATE BASE PLATE CONNECTION ATTACH 2"x3" TO BASE PLATE (INTERNAL) w/(2) #10x2" SMS 1/4" TAPCON (RED HEAD MFG. OR EQUAL) WITHIN 6" OF COLUMN 1112" PENETRATION INTO UNDERLYING FOOTING DETAIL "F" - DOOR JAMB & HEADER N 1-1/2"x2x.062 RECEIVER CHANNEL ALUMINUM INTERNAL OR EXTERNAL �� •• W/ (4) #124/4" TEKS RECEIVING CHANNEL w/(4) #10x3/4" \ Q (V LL LLI EACH SIDE (TYP.) INTO GIRT OR PURLIN & (4) #14x3/4" - O LL - J 0_ INTO BEAM OR UPRIGHT 0.062 ANGLE _= Z Q 0 (4) #10x11/2" SMS INTO CLIPS MAYBE USED I - (D• U (oQ _ _ n SCREW BOSSES = 5 )GE MEMBER 2 PURLIN PURLIN MEMBER i 1 d' CN UPRIGHT, BEAM -SNAP, �J C) J co 00 I0 L SELF MATING, OR HOLLOW I I J m o � �-- M co zZ Q o (0) U DETAIL "C" - GIRT OR PURLIN TO BEAM U � OR POST DETAIL SCALE: NTS O W -1 0 0 WLL U L Z Q� LLI o M � — H ^ c 2"x2"x063" - DIM. TO MATCH PURLIN O r SIZE RECEIVING CHANNEL PURLIN W (4) #12 SMS INTERNAL TO EAVE RAIL (2) #12 EACH SIDE INTO PURLIN Q 0 o U o------- o ( � - ------ . EAVE RAJ L - 3x2 I o �/ 0 Lo T- c:) i O �� 2x2xl25ANGLE 1x3OPEN BACK i UPRIGHT W/ (4) #14X3/4" TEKS EXTRUSION L1� co EACH SIDE I I 2x2xl/8 ANGLE EAVE RAIL T POST W/ (6) #14 EA CLIP i I I O I I U W DETAIL "G" - SLOPED PURLIN CONNECTION SCALE: NTS O Z _O H U D z LLi QU O m U U) W 2 w wz= r W o W a °- j� ¢ M�� �O YU w -jrnLL 0 z p J a DESIGN DATE: 5/4/2618 REVISION 1: DATE PAGE: REVISION 2: DATE SCALE: NTS BEAM 0 0 0 o o n CLOSE BOTTOM OF BEAM WHEN TRIMMED .044 RECEIVING CHANNEL, FASTEN w/(2) #12 SMS EACH SIDE OF BEAM 2x2x4x1/8" ANGLE EA. SIDE OF BEAT w/(4) #14 TEKS EACH LEG EACH FOR BEAMS ABOVE 2x8 INSTALL GUTTER BRACE AT MIDPOINT BETWEEN BEAMS & INCLUDE 2" GUTTER BRACE AT EACH BEAM LOCATION CORNER POST 1 ( —(2) #14x2" WOOD #12 SMS v I SCREW 18" O.C. 00 2x2x4 ANGLE W/ (4) #14 TEKS ® ro, SIDE VIEW l�h�— SCALE: NTS NOTE F INSTALL FASTENERS ALONG PERIMETER OF GUSSET -BEAM JOINT 3/8" MIN, FROM EDGE. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 FASTENER PATTERN MAY APPEAR DIFFERENT FROM ILLUSTRATION. MAINTAIN 1/2" SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8" MIN, FASTENER SEPARATION FROM BEAM JOINT OR EDGE OF BEAM LAP FASTENERS MAY BE EVENLY SPACED AROUND EDGE OF GUSSET WITHIN 3/8" OF BEAM JOINT. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 FASTEN GUTTER TO FASCIA w/ #14x2" WOOD SCREW 18" O.C. (2) #12 SMS (2)#14x2" WOODSCREW EXISTING WOOD FASCIA STRUCTURAL GUTTER 5052-H32 GUSSET bUKLVV UUANI I T 2X6 AND LESS THAN 3 ROWS OF (4) #14 FOR 2X7 AND GREATER 4 ROWS OF(4) #14 `NOTE: FOR SPANS OVER 33' ADD ANOTHER ROW DETAIL "K" GUSSET CONNECTION SCALE: NTS (2) #12 TEKS (IYP.) EA. MEMBER (FOR SPANS OVER 32' USE #14 TEKS) EAVE RAIL Vx3"O.B. PATIO SECTION x 3 x 0.05 CE (TYP.) K-BRACE LATERAL "W'-BRACING CONNECTION DETAILS (2) #12 SMS 2x2x1/8" ANGLE w/(2) GIRT #12 SMS EA. LEGS 1/8"x2"x4" STRAP (2) #12 SMS INTO BEAM (2) #12 SMS INTO GUTTER 2x2x1/8" ANGLE w/(2) #12 SMS EA. LEG . (2) #14 WOOD SCREWS INTO FASCIA 0 1, o I \ �i GIRT SIDE VIEW \ ' STRUCTURAL GUTTER GIRT GUTTER BRACES E FASCIA EACH SMS INTO GUTTER & (2) #14 WOOD SCREWS INTO FASCIA (2) #12 SMS SMB 00 1/8"x2"x4" STRAP (2) #12 SMS INTO BEAM GIRT (2) #12 SMS INTO GUTTER STRUCTURAL GUTTER ALTERNATELY USE 2x2x1/8 ANGLE TOP VIEW DETAIL "L" CORNER CONNECTION SCALE: NTS 6063-T6 ALLOY PLATE (ONE SIDE) OR STRONGER K-BRACE 2 x 3 x 0.050 CHAIR RAIL K-BRACE 2x3x0.050 BRACE-(TYP )- LATERAL "K"-BRACING CONNECTION DETAILS .050" GUTTER STIFFNER FASTEN TO FASIA w(2) #12x2" WOOD SCREW FASTEN TO GUTTER w(2) #12 SMS 1 x 3 x 0.050 RACE (TYP.) DETAIL "M" BEAM & PURLIN TO GUTTER CONNECTION SCALE: NTS \1-- C --- O O ----------- 0O 1-71 (2) #12 TEKS (lYI EA MEMBER-(FO SPANS OVER 32' USE #14 TEKS) \\\�1111111111111//////// N rr O J 'i 4t \ 4(/ N LL 4:.. LLI co O O �.J H cr, a- D- 00 _(D1W � 0 %y > Z cl) C1` M in m00 Ur co co Z 7 — Q Q U of p U W -J 000 r C M C c Z G O - COLUMN W < a) � 5 0 Lo �� o GIRT (CHAIR RAIL) LL WHEN BEAM & PURLIN HIT ON CORNER - FASTEN OUTSIDE OF BEAM & PURLIN w/ 1/8"x2"x2" ANGLE & (4) #12 SMS EACH LEG FASTEN INSIDE CORNER (BEAM TO PURLIN) w/ 1/8"x2'k2" ANGLE w/(2) #12 SMS INTO EA MEMBER (BEAM & PURLIN) N 00 0 M W U U d) O oo T_ z U LL1 0 a Z O I— U 1--' U_j U) Y Z LLi QU U 6 LU w of Z W W O U� o a W�a 201— U ~ O w � � U W't0 YU w .jrnLL Z O O a DESIGN DATE: 5/4/2018 REVISION 1: DATE PAGE: REVISION 2: DATE SCALE: NTS