HomeMy WebLinkAboutNOA'Sa • �r
_ — 3 SCANNED
a
a our,98 Co nn y
a
MI•DiADE
DEPARTMENT OF REGULATORY AND ECONOMIC
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA
RECE D
MAY 1 6 7n16
Permitting Department
(RER) St. Lucie County
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidadc.sov/economy
Petersen Aluminum Corporation
102 Northpoint Parkway, B1dg.106
Acworth, GA. 30102
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date s
(In Miami Dade County) and/or the AHJ (in areas oth(
or material tested for quality assurance purposes. If thi
manufacturer will incur the expense of such testing an,
of such product or material within their jurisdiction. P
determined by Miami -Dade County Product Control S
of the applicable building code.
This product is approved as described herein, and has
including the High Velocity Hurricane Zone of the Flc
ted below. The Miami -Dade County Product Control Section
than Miami Dade County) reserve the right to have this product
product or material fails to perform in the accepted manner, the
the AHJ may immediately revoke, modify, or suspend the use
iR reserves the right to revoke this acceptance, if it is
,tion that this product or material fails to meet the requirements
designed to comply with the Florida Building Code
Building Code.
DESCRIPTION: Edge-Loc 1.0: x 16" wide x 24 ga. Steel Panel over Wood Deck
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a! renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or (process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number precede ld by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA 14-0129.11 and consists of pages 1 through 5.
The submitted documentation was reviewed by Freddy Semino 301
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category
Roofing
Sub -Category:
Metal, Pa
Materials:
Steel
Deck Type:
Wood
Maximum Design Pressure
—101 psf.
TRADE NAMES OF PRODUCTS MANUFAC
Product Dimensions
Edge-Loc 1.0 Length: various
Width: 16"
Height: 1"
Thickness 0.024" (24 ga.)
Min. Yield Strength: 50 ksi
Trim Pieces Length: varies
Width: varies
Thickness 0.024" (24 ga.)
EVIDENCE SUBMITTED:
Test Agency Test Identif
Valspar 433X515
Valspar 433B173
Force Engineering & Testing 72-0314T-06.
Inc.
Farabaugh Engineering and T158-07�
Testing Inc.
I
I
I
D OR LABELED BY APPLICANT:
Test Product
ecifications Description
TAS 110 Corrosion resistant, prefmished, coated
galvanized, galvalume, standing seam, metal
panels.
N/A Corrosion resistant, prefinished, coated
galvanized, galvalume, standing seam, metal
panels.
Test Name/Report
Date
ASTM B 117
11/21/11
ASTM D 4587, ASTM G 23
11/21/11
TAS 125
03/24/07
TAS 100 04/14/07
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 2 of 5
APPROVED ASSEMBLIES:
System: Edge-Loc 1.0 Panel x 16" W
Deck Type:
Deck Description:
Slope Range:
Maximum Uplift
Pressure:
Wood, Non -Insulated
New Construction 19/32" or
greater plywood.
2": 12" or greater
See Table A below
x 24 ga. Steel
plywood or wood plank, or for re -roofing 15/32" or
I --
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum
15/32") The above attachment lmethod must be in addition to existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4"
side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps
and 12 gauge 1 ''/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered
rows 12" o.c. in the field of thi roll. Or; any approved underlayment having a current NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with PAC Contractors As current published installation instructions.
I
Metal Panels and Install the "Edge-Loc 1.0 Panel" and accessories in compliance with the current published
Accessories: installation instructions and details in PAC Contractors Association's Installation Manual.
Flashings, penetrations, valley construction and other details shall be constructed in
compliance with Roofing Application Standard RAS 133.
Panels shall be secured at a spacing listed below in Table A with corrosion resistant 410-13
x 1" pancake head screws of ufficient length to penetrate through the sheathing a minimum
3/16 of an inch.
The adjacent panel shall overlap and be secured to each other when The female rib of panel
is snapped over the male rib i of panel.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Corner'
Maximum Design Pressures
—59.75 pst
—101 psf.
Maximum Screw Spacing
16" o.c.
6.75" o.c.
1. Extrapolation shall not be allowed
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 3 of 5
SYSTEM LIMITATIONS
I. Fire classification is not part of this acceptance; refer
ratings of this product.
a current Approved Roofing Materials Directory for fire
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapola lion shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. Panels may be rolls formed in continuous lengths fro eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133.
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city, state, and the following
statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control
Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or
model.
MIAMI-DADE COUNTY
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
6. Panels maybe shop or jobsite roll formed with machine models # 10110884, E00578860, or 01110072 from
PAC Contractors Association or manufactured at Petersen Aluminum Corporation's plant in Acworth, GA.
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 4 of 5
Field Condition
EDGE-Loc 1.0 PANEL SYSTEM
END OF THIS ACCEPTANCE
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 5 of 5
{
RECEIVED
THESE PLANS AND ALL PROPOSED WOF
MRE SUBJECT TO ANY CORRECTIONS
IMAMQUIRED BY FIELD INSPECTORS THAT
Y BE NECESSARY IN ORDER TO
WN OMPLY WITH ALL APPLICABLE CODES
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURC
BOARD AND CODE ADMINISTRATION DIVISION
Tr -
NOTICE OF ACCEPTANCE I
MAY -1 61018
Permitting Department
St. Lucie County
MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
(RER)
11805 SW 26 Street, Room 208
05 D Li -
Miami, Florida 33175-2474
,, rat__
��Lkc "'"-
T (786) 315-2590 F (786) 315-2599
www.miamidade.sov/economv
. a-v\ .1- _WWII I I o�llLV11VV U1 OWN
Owens Corning REVIEWED FOR COMPLIANC
One Owens CorningParkway REVIEWMEpI B
Toledo, OH 43659 DATE 3'L
PLANS AND PERMIT MUST BE KEPT ON JOB
SCOPE: SITE OR ND INSPECTION(S) WILL BE MADE
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted b) Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated
(In Miami Dade County) and/or the AHJ (in areas other that
product or material tested for quality assurance purposes. If
manner, the manufacturer will incur the expense of such test
suspend the use of such product or material within their juri
if it is determined by Miami -Dade County Product Control
requirements of the applicable building code.
This product is approved as described herein, and has been
including the High Velocity Hurricane Zone of the Florida I
DESCRIPTION: WeatherlocV Specialty Tile & Metal
elow. The Miami -Dade County Product Control Section
Miami Dade County) reserve the right to have this
his product or material fails to perform in the accepted
ng and the AHJ may immediately revoke, modify, or
diction. RER reserves the right to revoke this acceptance,
-ction that this product or material fails to meet the
to comply with the Florida Building Code
Code.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expirati,
materials, use, and/or manufacture of the product or process
for sales, advertising or any other purposes shall automatica
of this NOA shall be cause for termination and removal of r
ADVERTISEMENT: The NOA number preceded by
by the expiration date may be displayed in advertising
it shall be done in its entirety.
n date or if there has been a revision or change in the
Misuse of this NOA as an endorsement of any product,
y terminate this NOA. Failure to comply with any section
words Miami -Dade County, Florida, and followed
ature. If any portion of the NOA is displayed, then
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 13-1010.03 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
x
i ER'e'S OR ATTACHN{I= Vi TS
E RESPONSIBILITY OF THE NOA No.: 17-0522.01
CMIAMI.M= CONTRACTOR OR RECORD Expiration Date: 07/31/18
Approval Date: 07/27/17
FILE COPY Page 1 of 4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS
TRADE NAMES OF PRODUCTS MANUFACTURED
Test
Product Dimensions Specificat
Weatherlock® 36" x 33.3' rolls TAS 10:
Specialty Tile & 36" x 66.7' rolls ASTM D 1
Metal Underlayment
MANUFACTURIGN LOCATION:
1. Brentwood,. NH.
2. Houston, TX.
EVIDENCE SUBMITTED:
Test Agency
Underwriters Laboratories, Inc.
IRT-Arcon, Inc.
PRI Asphalt Technologies, Inc.
PRI Construction Materials
Technologies, LLC.
Test Identifier
R14610
02-012
NEI-006-02-01
NEI-008-02-01
NEI-045-02-01
NEI-053-02-01
NEI-076-02-01
NEI-034-02-02
OCF-312-02-01
OCF-320-02-01
LABELED BY APPLICANT:
Product
Description
SBS self -adhering asphalt sheet material with a
white or green glass re -enforced polyester
surfacing fabric; for use as an underlayment in
sloped roof assemblies.
Test Name/Report
Follow up Service
TAS 103
TAS 103
TAS 114 (H)
ASTM D 4798 & ASTM G 155
ASTM D 4798 & ASTM G 155
TAS 103 / ASTM D4798
ASTM D 1970
ASTM D 1623
TAS 103
Date
03/28/02
02/28/02
04/01/02
07/30/02
08/08/07
05/01/08
02/14/11
10/28/13
07/03/17
06/28/17
NOA No.:. 17-0522.01
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 2 of 4
APPROVED ASSEMBLIES:
Deck Type 1: Wood, non -insulated, new construction
Deck Description: 15/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened deck, membrane adhered.
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" side lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane: One or more plies of Weatherlock® Specialty Tile & Metal Underlayment with a minimum 3"
side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied. Vertical strapping of the roof (with Weatherlock® Specialty Tile & Metal Underlayment
is acceptable.
Surfacing: Approved for Adhered Roof Tile using, TILE BOND or AH-160, Mechanically Fastened Roof
Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies.
NOA No.: 17-0522.01
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 3 of 4
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications.
applicable building code. Weatherlock® Specialty
compliance with applicable Building Code.
3. Weatherlock® Specialty Tile & Metal underlayment sl
free of irregularities.
4. Weatherlock® Specialty Tile & Metal underlayment
recover, but may be applied over roofing Base/Anchor
5. Weatherlock® Specialty Tile & Metal underlayment s.
90 days of application.
6. The standard maximum roof pitch for Weatherlock® S
are loaded directly to the Weatherlock® Specialty 'I
required on roof pitches greater than 6:12".
[mum deck requirements shall. be in compliance with
& Metal underlayment shall be installed in strict
be applied to a smooth, clean and dry surface with deck
1 not be applied over an existing roof membrane as a
;t underlayment.
not be left exposed as a temporary roof for longer than
alty Tile & Metal underlayment shall be 6:12 when tiles
& Metal underlayment; loading boards or battens are
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
8. Tiles shall be stored on battens on roof pitches greater than 6:12".
9. Weatherlock® Specialty Tile & Metal underlayment may be used with any approved roof covering Notice of
Acceptance listing Weatherlock® Specialty Tile & Metal underlayment as a component part of an assembly in the
Notice of Acceptance. If Weatherlock® Specialty Tile & Metal underlayment is not listed, a request may be made
to the Authority Having Jurisdiction (AHJ) or the Miani-Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance,
and fire testing results.
10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior io application.
11. When applying the membrane in the valley, start at the lew point and work to the high point, rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice ofAcceptance and applicable Building Code.
14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Weatherlock® Specialty
Tile & Metal underlayment shall be applied over the underlayment.
15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and
the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product
Control Seal as shown below.
MIAMI•DADE COUNTY
END OF THIS ACCEPTANCE
MIAMI•DADE COUNTY
NOA No.: 17-0522.01
Expiration Date: 07/31/18
Approval Date: 07/27/17