Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GENERATOR
SCANNED By St Lucie Count,/ 16/20/22 kW INCLUDES: • True PowerT"° Electrical Technology • Two Line LCD Multilingual Digital Evolution TM Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Capability to be installed within 18" (457 mm) of a building* FEATURES • GENERAL001=1111011M - GUARDIAN® SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Mode s G007036-0, G007037-0 (Aluminum - Bisque) -16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz odels,G007043 1_,.G0070421(ALuminurLhBisque)_. 2 kW 60 Hz O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER' ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. c Rus Q' / LISTED vJ" Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAL TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAL POWER SYSTEMS. One reason for this J SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY confidence is that the GENERAL product line includes its own transfer systems and controls for total system compatibility. w G E N E R A C atT"3s y4� _ ; • ®• *©* Mobile, i I— PROMISE `TTONEP `r0 �4RRP�` Link "Bull( In the BSA wing domesda and lamlon parts. GENERAC® 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased1fuel efficiency. Plateau honed cylinderwalls and plasma moly rings helpsthe engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability prlovide long engine life. • Electronic ignition/spark advance These features combine to assure smooth! quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearing means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit thatioperates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents i damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution pai el for simple, low-cost installation. Evolution- Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to, ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown setpoint approximately 1 minute. • Programmable exercise i Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when leeded at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System • 1 It (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. I GENERAG 16/20/22 W specification; Generator Model G007035-0, 0007036-0, G007038-0, G007039-0 13007042-11, G007043-1 G007037-0 (16 kW) (20 kW) (22 kW) _0j' raq ff'(CP ffiW5L- _fflff Rated Maximum Continuous Power Capacity (NG) 16,000 Wafts* 18,000 Wafts* 19,500 U12% 'r". N.R. ®RN ,,Rat ii.lffltii M 4 011 Rated Maximum Continuous Load Current - 240 Volts (LP/NG) 66.6/66.6 83.9fl5 91.6/81.3 2 1-M M_02, HE It MORld 5 PAU Rp,'E �`T �r 1P my.mc;R @fN C,6052N NEW E MR2,;'M M ,E _ Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Eg ffT� g rgw FEE MR, Number of Rotor Poles 2 2 2 Power Factor 1 0 1 0 10 a Unit Weight (lb/kg) 6/211 Sound output in dB(A) at 23 it (7 m) with generator operating at normal load** 66 66 67 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Displacement 999 cc 999 cc 999 cc @W—Rd..'r-RIVNE Valve Arrangement Overhead Valve Overhead Valve Overhead Valve ..agg g MR, pg p.; g- ��Pjg rbI@—ds1aL!ff aggogfg-t Pl�,,-�XWRN54 41R.-'1P 0.10, A * 't M—MMM Mlv.-,�-ffiom ;il" , gqwg g7 Governor System Electronic Electronic Electronic Controls 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. MIMN 0-� TE L Zqk� 11'1� "I i I V., e R. Ed Nt fal- Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 2-1500 Smart Battery Charger Standard Warning I Standard Overcurrent Protection Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard g�j�7 z 15—ff-KeEs CLdt�LhNq_�N Rr Lq_n_�� CvRsr 'IT High Engine Temperature Shutdown Standard Common External Fault Standard —Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator maybe higher depending on installation parameters. Rating definitions -Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability Is available for this raring. (All ratings In accordance with BS5514, IS03046 and DIN6271). *Maximurn kilovolt amps and current are subject to and limited by such factors as fuel Btur/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percentior each 6 IG (101F) above 16113 (60*F). i GENERAC' MEMENON 16/20/22 kW switch options Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 210-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resis- tive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240, to Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 G007036.0 Rating (Amps) 100 Monitor (Fixed)' 80% 65% bi-weekly for 5 minutes"t Standard Circuits Available 24 Circuit Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly 1- DEPTH G007037.0 (16 kW)/G007039-0 (20 kW)/ Model G007043-0 (22 kW) jIN'o of:Pores ��.� �°..y�.:..y;�:t.�:"t? �,�:'=-,.T_.,-,��...^2 a�,��;�"—,rw:.<.�"`•�� Current Rating (Amps) 200 Utility Voltage Monitor (Fixed)' -Pick-up 80% I -Dropout 65% Return toUtllity"7221e13�se_c*'dv� Exercises bi-weekly for 5 minutes' Standard 1.t1Sed gay r r "y O��P 'Sta and r_3� Enclosure Type NEMA(UL 3R LOIrcwC9_reaker Protected i Lug Range 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly L DEPTH -1 16/20/22 kW GENERAC available accessories RE=�,c3",t:.g'T, ,�-,t„_""".L a� -..,.t .t �`.'" Model #' ��Rroduct G007005-0 ;T'F'� 'a'+ `= 1 J3� if%3'L' s•" v�� �Descrtptton 1Wi-Fi LP Fuel Level Monitor -+.�::.. �^`' L'?_ ;i-i'"""� i�,"q v'„J "1 '".- "L'".x ti '�S�' T,�� t'r 't"• !+. Y x Hfi 1 ? t. $ s` hr r ,�� �r y r µ�W. Si.. 7q The W!-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon; itoring the LP tank's fuel leve� is an important step in making sure your generator is ready to run during an0 unexpected powerfailure. Status alerts are available through a free application to notify when your LP tank i is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac G006463-4 Mobile Link'" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or! U.S. j G005819-0 I 26R Wet Cell Battery text message when a change in the generator's status occurs. Available in the only, I Every standby generator requires a batteryto startthe system. Generac offers the recommended 26R wet; cell I battery for use with all air-cooled standby product (excluding PowerPact®). i -._.er F:•- 1The warmer rests underthebattery. Recommended for use •Ifthe temperature regularly falls below 0°F.j 0071....._,,_ ! G007101-0 Battery Pad Warmer atteyPa pad (Not necessary for use with AGM -style batteries). Oil warmer slips directly over' the oil filter. Recommended for use if the temperature regularly falls below G007102 0 I Oil Warmer 0°F s Auxiliary Transfer Switch fThe auxiliary transfer switch bontact kit allows the transfer switch to lock out a single large electrical load G005621 0 Contact Kit !you may not need. Not compatible with 50 amp pre -wired switches. V G007027-0 - Bisque _ Fascia Base Wrap Kit r (Standard on 22 kW) {The fascia base wrap snaps sleek, contoured appearance together around the bottom of the new air cooled generators. This offers a as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0 - Bisque Paint Kit If the generator enclosure is Ifuture corrosion. The paint kit scratched or damaged, it is important to touch-up the paint to protect from I includes the necessary paint to properly maintain or touch-up a generator enclosure. G006 G006 485 0 Scheduled Maintenance Kit � Generac's scheduled mainte kits provide all the hardware necessary to perform complete routine arTjance on a Generac h tomatic standby generator.. G006873-0 �h -maintenance Smart Management Modulesl are used in conjunction with the Automatic Transfer Switch to increase INS Smart Management Module (50 Amps) power management capabilities. It provides additional power management flexibility notfound in any other power management system. Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO LEFT SIDE VIEW taax Ini FROM VIEW dimensions & UPCs THESE DIMENSIONS FOR INSTALLATION PURPOSES. Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 0007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 GENE RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 100000001 94-F 5/3/17 N N O to ro T 5of5 =110 volt duplex receptacle Cat 5 data drops