HomeMy WebLinkAboutPRODUCT REPORTCompliant with Florida Building Code 201
Compliant with Florida Product Approval
Compliant: Keystone Certifications
Product: 1" Nailstrip 26GA Steel Roof
Yield strength: 50 ksi min.; A
Wood Deck w/ 0.42 specific
Rib Height 1"
Corrosion Resistant Compliant: FBC S,
Fastener 1: #10 x 1" (min.) Pancake Hi
bottom of support.
Adhesive/Sealant : Bostik 9151 Chem
3/16" continuous bead application alc
seam.
Underlayment: To be compliant with
Slope: Shall be in compliance with FBC
Install Details: Table A Allowable Loads
DESIGN PRESSURE*
FASTENER SPACING
SEAM ADHESIVE
SCANNED
2160 SW Poma Drive
Palm City, FL 34990
(6th ed.) RECEIVED
ule # 61G20-3
MAY 16 2018
ST. Lucie countyt Permitting
FBC Sec.1507.4.2
ed to min.15/32" plywood or
ty with 16" Coverage (Max.)
1507.4.3
Wood Screw to penetrate 3/16" (min.) thru
alk one component, polyurethane adhesive with
base of male rib vertical flange at each panel
Sec 1507.1.1
1507.
M_E-THOD_i_, METHOD 2
-97.25 PSF Perimeter
a!AFO 6" O.C.
Not.rei ed 3/16" continuous bead
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
EQUIVALENCY- UL1897-04 is equivalent to Test Standard UL1897--12. *Design Pressure margin of safety 2:1
Certificate of independence:
Locke Bowden, P.E. does not have, not will acquire a;financial iiStli11y, cc
under this evaluation. C • gr3L`; ;�
Locke Bowden, P.E. is not owned, operated, or controlleel��i►�y'�c d ai
report.
x
•.a. •�=
•� STATE OF
NAL. ;;...
manufacturing or distributing products
, or distributing products under this
'17
seal
i
I
I
i
FL 17022.6 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details
1" Nail Strip Roof Panel
Deck:
15132" or greater Plywood, or
Wood plank
Fastener
#10 X 1" Min. per Table "A"
Pancake Head Wood Screw
Isometric View
Seam Adhesive Application:
For Method 2
Apply 3116" Bead Bostik 915Tm Sealant
Continuous Along Male Rib Vertical Flange
(Refer to Table "A")
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6"' ed..
2. Minimum slope to be compliant with Florida Building Code 2017 6t° ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for °project specific approval by local authorities wfjudsdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 61h ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading. 1
7. This report does not imply warranty, installation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
ranee rroine
16" o.c.
� Deck:
-15/32" or greater Plywood, or
- Wood plank
__----.Integral Snap Lock
For METHOD 2:
Apply 3/16" Bead Bostik 915Tm Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 X 1" Min. perTable "A"
Pancake Head Wood Screw
i
(Typical Fasi ening Pattern Across Width)