NOTICE OF ACCEPTANCE (NOA) vww.miamidade.aov/economy
Petersen Aluminum Corporation THESE PLANS AND ALL PROPOSED WORK
102 Northpoint Parkway, Bldg.106 i ARE SUBJECT TO ANY CORRECTIONS
Acworth, GA. 30102 REQUIRED BY FIELD INSPECTORS THAT
COMPLMAY SCOPE: �
NECESSARY
WITH ALL APPLOICABLE CODES.
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
1
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of 'such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Edge-Loc 1.0if x 16" wide x 24 ga. Steel Panel over Wood Deck
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County;Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code;negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for, termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official. CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
This NOA renews and revises NOA 14-0129.11 and consists of pages 1 through 5. CONTRACTOR OR RECORD
The submitted documentation was reviewed by Freddy Semino
FILE y�ri
ST. LUCIE COUNTY BUILDING DIVISION J NOA No.: 17-1002.16
MAMNDADECOUNTY REVIEWED FOR COMPLIANCE/` Expiration Date: 03/16/24
REVIEWED D Approval Date: 11/02/17
DATE XG I y Page 1 of 5
PLANS AND PERMIT MUST BE K ON JOB
SITE OR NO INSPECTIONS) WILL BE MADE
ROOFING ASSEMBLY APPROVAL I
Roofing
Category
Sub -Category:
Metal, Pan
Materials:
Steel /
Deck Type:
Wood
Maximum Design Pressure
—101 �PSL
TRADE NAMES OF PRODUCTS
Product
Edge-Loc 1.0
ACTURED OR LABELED BY APPLICANT:
Test Product
Dimensions 1 Specifications Description
Length: various; TAS 110 Corrosion resistant, prefmished, coated
Width: 16" galvanized, galvalume, standing seam, metal
Height: 1" panels.
Thickness 0.024" (24 ga.)
Min. Yield Strength: 50 ksi
Trim Pieces Length: varies
Width: varies
Thickness 0.024I' (24 ga.)
EVIDENCE SUBMITTED: l�
Test Agency �' Test Identifier
Valspar 433X515
Valspar 433B173
Force Engineering & Testing ! 72-0314T-06A-C
Inc.
1
Farabaugh Engineering and T158-07A
Testing Inc.
N/A Corrosion resistant, prefmished, coated
galvanized, galvalume, standing seam, metal
panels.
Test Name/Report
Date
ASTM B 117
11/21/11
ASTM D 4587, ASTM G 23
11/21/11
TAS 125
03/24/07
TAS 100 04/14/07
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 2 of 5
APPROVED ASSEMBLIES:
System: Edge-Loc 1.0 Panel x 116" Wide x 24 ga. Steel
Deck Type:
Deck Description:
Slope Range:
Maximum Uplift
Pressure:
Wood, Non -Insulated
New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or
greater plywood.
2": 12" or greater I
See Table A below i
Deck Attachment:
i
In accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6" lo.c. In reroofing, where the deck is less than 19/32" thick -(Minimum
15/32") The above attachment method must be in addition to existing attachment.
Underlayment:
Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4"
side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps
and 12 gauge 1 1/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered
rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA.
Fire Barrier Board:
Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See (limitation # 1.
Valleys:
Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with PAC Contractors Association's current published installation instructions.
Metal Panels and
Install the "Edge-L I c 1.0 Panel" and accessories in compliance with the current published
Accessories:
installation instructions and details in PAC Contractors Association's Installation Manual.
Flashings, penetrations, valley construction and other details shall be constructed in
compliance with Roofing Application Standard RAS 133.
Panels shall be secu, red at a spacing listed below in Table A with corrosion resistant #10-13
x 1" pancake head screws of sufficient length to penetrate through the sheathing a minimum
3/16 of an inch.
The adjacent panel shall overlap and be secured to each other when The female rib of panel
is snapped over the male rib of panel.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Corners
Maximum Design Pressures
—59.75 psf.
—101 psf.
Maximum Screw Spacing
16" o.c.
6.75" o.c.
1. Extrapolation shall not be allowed
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 3 of 5
SYSTEM LIMITATIONS
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners): Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133.
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city, state, and the following
statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control
Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or
model.
5. All products listed herein shall have a quality assui
Rule 61 G20-3 of the Florida Administrative Code.
6. Panels may be shop or jobsite roll formed with m
PAC Contractors Association or manufactured at
audit in accordance with the Florida Building Code and
models # 10110884, E00578860, or 01110072 from
;n Aluminum Corporation's plant in Acworth, GA.
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 4 of 5
T
1
PROFILE DRAWINGS
16"
Fastener Relief, Stiffening Ribs and Striations are Optional
Field Condition
EDGE-LOC 1.0 PANEL SYSTEM
END OF THIS ACCEPTANCE
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 5 of 5
RECEIVED
MAY 1 61010
HAW Permitting Department
® St. LurJe County
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION il
NOTICE OF ACCEPTANCE
Owens Corning
One Owens CorningParkway
Toledo, OH 43659
MIAMI-DADS COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/economv
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Weatherlock® Specialty Tile & Metal Underlayment
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 13-1010.03 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0522.01
MLAMi•DADE COUNTY Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 1 of 4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
Weatherlock® 36" x 33.3' rolls TAS�1103 SBS self -adhering asphalt sheet material with a
Specialty Tile & 36" x 66.7' rolls ASTM D 1970 white or green glass re -enforced polyester
Metal Underlayment surfacing fabric; for use as an underlayment in
sloped roof assemblies.
MANUFACTURIGN LOCATION:
1. Brentwood, NH.
2. Houston, TX.
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Underwriters Laboratories, Inc.
R14610
Follow up Service
03/28/02
IRT-Arcon, Inc.
02-012
TAS 103
02/28/02
PRI Asphalt Technologies, Inc.
NEI-006-02-01
TAS 103
04/01/02
NEI-008-02-01
TAS 114 (H)
07/30/02
PRI Construction Materials
NEI-045-02-01
ASTM D 4798 & ASTM G 155
08/08/07
Technologies, LLC.
NEI-053-02-01
ASTM D 4798 & ASTM G 155
05/01/08
NEI-076-02-01
I TAS 103 / ASTM D4798
02/14/11
NEI-034-02-02
ASTM D 1970
10/28/13
OCF-312-02-01
ASTM D 1623
07/03/17
OCF-320-02-01
TAS 103
06/28/17
I
NOA No.: 17-0522.01
MLAMi•Dane COUNTY
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 2 of 4
APPROVED ASSEMBLIES:
Deck Type 1: Wood, non -insulated, new construction
Deck Description: 15/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened deck, membrane adhered.
i
Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626 with a minimum 4" side lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane: One or more plies of Weatherlock® Specialty Tile & Metal Underlayment with a minimum 3"
side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied.. Vertical strapping of the roof with Weatherlock® Specialty Tile & Metal Underlayment
is acceptable. I
Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH-160, Mechanically Fastened Roof
Tile, Metal Roofing, Wood Shake & 'Shingles, and Asphaltic Shingle assemblies.
NOA No.: 17-0522.01
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 3 of 4
LINIITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. Weatherlock® Specialty Tile & Metal underlayment shall be installed in strict
compliance with applicable Building Code.
3. Weatherlock® Specialty Tile & Metal underlayment shall be applied to a smooth, clean and dry surface with deck
free of irregularities.
4. Weatherlock® Specialty Tile & Metal underlayment shall not be applied over an existing roof membrane as a
recover, but may be applied over roofing Base/Anchor sheet underlayment.
5. Weatherlock® Specialty Tile & Metal underlayment shall not be left exposed as a temporary roof for longer than
90 days of application.
6. The standard maximum roof pitch for Weatherlock® Specialty Tile & Metal underlayment shall be 6:12 when tiles
are loaded directly to the Weatherlock® Specialty Tile & Metal underlayment; loading boards or battens are
required on roof pitches greater than 6:12".
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
8. Tiles shall be stored on battens on roof pitches greater than 6:12".
9. Weatherlock® Specialty Tile & Metal underlayment, may be used with any approved roof covering Notice of
Acceptance listing Weatherlock® Specialty Tile & Metal underlayment as a component part of an assembly in the
Notice of Acceptance. If Weatherlock® Specialty Tile & Metal underlayment is not listed, a request may be made
to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance,
and fire testing results.
10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior, to application.
11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions. i
12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Weatherlock® Specialty
Tile & Metal underlayment shall be applied over the underlayment.
15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and
the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product
Control Seal as shown below.
END OF THIS ACCEPTANCE
NOA No.: 17-0522.01
MuvMI•oane cour�rr Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 4 of 4