HomeMy WebLinkAboutPRODUCT APPROVALay rdim 0-114, rL a&+»v Compliant with Florida Building Code 2017 (611 ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient- length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads fit. METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" o.c. 16" O.C. 8" G.C. 6" o.c. FASTENER -SPACING (ALONG Panel width) 12" o.c. 12" o.c. 12" o.c. 12" o.c. FASTENER SIZE 1 #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test Report 1315893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1 *Design pressure margin of safety 2:1 Ir fnrri Locke Bowden, P.E. does not have, not will acquire a financial in4t1q��cggym.AWfacturing or distributing products under this evaluation. - • Locke Bowden, P.E. is not owned, operated, or controlled by a& coApar(Vpmbililiatturep, or distributing products under this report. ' 1 � �$Ti11 is 4 e IrCOUNTY BUILD DIVISION I L 0•.�COft1C�®a".yc;� REVIEWED FOR COMP E r�!@ �i��t +j` f ° r .. • J�o?' REVIEWED W E �/ ONAL - •rt::.,►►ti►e PLANS A ERM MUST BE KEPT ON ]OE SITE OR NO INSPECTIONS) WILL BE MADI FL17022.1 i,�Crimp (26GA Steel), 24" Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th -ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. — Fasteners - #9 x 11/2' Min. or #10 x 1-1/2° Min. per Table A' for Row 5-V Crimp Roof Panel Spacing and Design Pressures Hex Washer Head Wood Screws Deck: -15132" or greater Plywood, or -Wood plank 247 12" 3/8" T_ OP7l0NA1 STRIATIONS Panel Profile Nominal12" _ Nominal12" O.C. O.C. Fasten 9 x -1/2" Min. or #10 x 1-1/2" Min. per "Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or -Wood plank