Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILESFlorida Building Code Online Page 1 of 2 *+,bs ;. V I� SCANNED s. LA BY St Lucie County l �. 1 i i FBC Staff BCIS Site Map i Links Search BQS Home Log In User Registration ; Hot Topic I s ; Submit Surcharge Stats & Facts Publications 0,'TeProductApproval USER: Public User Product Approval Menu > Product of Application Search I> Applicatio Lis n Application Detail Application Type I Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Entegra Roof Tile, LLC 1289 NE 9th Avenue Okeechobee, FL 34972 (602) 515-6933 thomas.jemmett@boral.com Thomas Jemmett tliomas.jemmett@boral.com Roofing Roofing Tiles Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name wh10 developed Robert Nieminen the Evaluation Report Florida license Quality Assurance Entity Quality Assurance Contract Expiration) Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By PE-59166 PRI Construction Materials Technologies, LLC 11/02/2018 John W. Knezevich, PE J. Validation Checklist - Hardcopy Received FL7804 R10 COI 2016 01 COI Nleminen.pdf Standard year ASTM C1492 2003 FRSA/TRI April 2012 2012 SSTD 11 1997 TAS 100 1995 TAS 101 1995 TAS 102 1995 TAS 102(A) 1995 TAS 112 1995 httn://ww.floridabuilding,.org/pr/pr app w_dtl.asp:c?paratn=,k&,GEVXQwtD±7uovojOMG/o2bA... 4/4/2019 Florida Building Code Online Page 2of2 a � Sections from the Code I Product Approval Method Method 1 Option D Date Submitted 10/17/2017 Date Validated 10/19/2017 Date Pending FBC Approval 10/22/2017 Date Approved 12/12,1201- I Summary of Product. FL # Model, Number or Name Description 17804.1 Entegra Concrete Roof Tiles (HVHZ Concrete Roof Tile jurisdictions) I Limits of Use I Installation Instructions i Approved for use in HVHZ: Yes FL7804_._R10- II__20L7__10 _FINAL ER__ENTEGRA__ FL7304 Approved for use outside HVHZ: No R10_ HVHZ,ptif impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: NJA Created by Independentihird Party: Yes Other: Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports Section 6 for Installation. FL7804 R10 AE 2017 SO FINAL ER ENTEGRA FL7804- R10 HVHZ.pdf Created by Independent Third Party: Yes r•--ter-- �re--•. 7804.2 t 1Egra Gdncrete Roof TIIes n n ' 'Concrete Roof Tile HUHZ,Iurisdlctio Limits of Use Installation Instructions Approved for use in HVHZ: No FL7804 _RI,D II 2017 10 FINAL ER _ENTFGRAFL7804� Approved for use outside HVHZ: Yes R10 NON_HV�iZ.pdf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits,' of Use. Refer to ER Evaluation Reports Section 6 for Installation. FL7804 RIO AE 2017 10 FINAL ER ENTEGRA FL7804- RIO NON-HVHZ.pdf Created by Independent Third Party: Yes Saclt Nc. I Contact Usl:: 2601 Blair Stone Road Tallahassee FL 3Z399 Phone: 950-497-1824 The Stale of Florida Is an AA/EEO employer. tyonvrioht 2007-2013 State of florida.:: Privacy Statement :: AttessibillN Statement :: Refund Statement Under Florida law, email addresses are public relcords. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. `Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaik provided may be used jfor official communication v6th the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, FS., please click here . Product Approval Accepts: Tfl 50 EtFri M Credii. Card Safe -M f7 , i. http: //wwav_fl or-i dabLiil ding. oi-gJpr/pr_app_dtl. aspx?parai7i=wGEVXQwtDquovoi OHI%2bA... 4/4/2018 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 ERD OXFORD, CT 06478 (203)262-9245 EVALUATION REPORT i Entegra Roof Tile, LLC Evaluation Report E39310.11.11-2-R5 YNTEGRA 1289 NE 9th Avenue FL7804-R10 " e5l�. I ° ^ f.. i Okeechobee, FL 34972 Date of Issuance: 11/02/2011 (602) 515-6933 I Revision 5 :10/17/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated fir compliance with the a Edition (2017) Florida Building Code (non- HVHZ) sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles (non- HVHZ jurisdictions) LABELING: Labeling shall be in accordance vlitll the requires ens the Aer_sedlted Quavkt- AScLt53?lca 1�AP 1C\{ nt?t?� herein. I CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. I t�Sitt�Fc,YS�'IdiE14�: �Tre�rvdrerdi�rrtl'?� ,rri Trfrrn'rrc'f,FYIEL %>✓`'�'uy&tE!v�tertus"iTli7tt�YyE%3��diiiaiEtS" m-aVbedisplayedin advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59156, Florida DCA AIVE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10117/2017. This does not serve as an electrortcally signed document. CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any —way, the Designer of Record for arty project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing I Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the 6`h Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a I Standard Year 1507.3.5, R905.3.5 Physical Propertiesi ASTM C1492 2003(2009) 1507.3.7, R905.3.7 Attachment Requi ements FRSA/TRI April 2012 (04-12) 2012 1504.2.1.1 Overturning Moment SSTD 11 1997 3" REFERENCES: Entity Examination Reference Date ATL(TST3782) Physical Properties RT0615.01-11 06/28/2011 ATL(TST3782) Physical Properties RT0615.02-11 06/28/2011 ATL(TST3782) PhysicalProperti6 RT0615.03-11 06/28/2011 ATL(TST3782) Physical Properties RT0615.04-11 06/28/2011 ATL(TST3782) Physical Properties RT0615.05-11 06/28/2011 ATL(TST3782) Physical Properties RT0316.01-12 05/31/2012 ATL (TST 3782) Physical Properties RT1103.01-15 11/07/2015 ATL (TST 3782) Physical Properties RT2103.02-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.03-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.04-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.05-15 11/07/2015 PRI (TST5878) Physical Properties ESI-001-02-01 11/06/2006 PRI (TST5878) Physical Properties ESI-002-02-01 11/06/2006 PRI (TST5878) Physical Properties ESI-003-02-01 11/06/2006 PRI (TST5878) Physical Properties ESI-004-02-01 11/06/2006 PRI (T5-T3878) Trhysical Properties 1 51-0U3-02-01 12117112006 PRI (TST5878) Physical Properties HRT-023-02-01 11/19/2007 PRI (TST5878) Physical Properties HRT-026-02-01 01/08/2008 Tile Roof Institute SSTD 11 1Membership Confirmation Current PRI (QUA9110) Quality Assurance I Service Confirmation Exp. 11/02/2018 Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-2-R5 Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 5: 10/17/2017 Page 2 of 6 4. PRODUCT DESCRIPTION: 4.1 1 ASTM C14492, Type III (law -profile) . 1-1/TS' T I Y BE Horizon Flat u .� 1 ERD T BERMUDA FLAT, PLANTATION FEAT and HORIZON FLAT Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-2-RS Certificate ojAuthorizotion #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision S: 10/17/2017 Page 3 of 6 i I ' ED I 4.2 ASTM D7 492Y Type (l: (medium -profile) 13ELLA IiIGH "S"� EsTAit "S"'and:HAciENbA . - L Bella High "S" Estate "S" 4.3 ASTiyi C1492, Type.1(high-profile) GALENA SPANISH "S" and REGAL Galena Spanish "S" Exterior Research and Design, I.I.C. Certificate oJAuthorization #9503 6" EDITION:(2017) FBC NON-HVHZ EVALUATION i Entegra Roof Tiles Regal Evaluation Report E39310.11.11-2-R5 FL7804-R10 Revision 5: 10117/2017 Page 4 of 6 f TRINITY:; ERD S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer otRecord for any project on w'hicn this Evaluattion Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire classification is not part of this evaluation; refer to FBC 1505.2, Exception 2 (for non-combustible deck) or listing by an approved testing agency for fire rating of this product. 5.4 Underlayment shall hold Florida Local or Statewide Product Approval for use with tile roofing. systems. The underlayment Product Approval shag' specr€y allor;sa:,-ge 'WstaNa V--, �i 7t'Cric?irf a�i attachment, mortar -set and/or adhesive -set) for use with the specific underlayment. For mortar -set or adhesive -set tile roofing applications ,1 the underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12). 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. (p(,STArl LET R,' 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of FBC 1507.3, the FRSAJTRI April 2012 (04-12) and, for mortar -set or adhesive -set applications, the mortar or adhesive manufacturer's Product Approval. 6.2 Underlayment shall be installed in' accordance with FRSAJTRI April 2012 (04-12) or the underlayment manufacturer's current Product Approval. For mortar -set or adhesive -set tale roofing applications, the underlayment current Product Apprbval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12). 6.3 Attachment: 6.3.1 Mechanically Attached Tile: Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift Moment determined in Table 2A or 26 of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3. 6.3.2 Mortar -Set Tile: Wind load resistance shall be in accordance with Table 2A or 213 of FRSAJTRI April 2012 (04-12) or FBC 1609.5.3 in conjunction with the mortar manufacturer's Product Approval. 6.3.3 Adhesive -Set Tile: Wind load resistance shall be in accordance with Table 2A or 213 of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3 in conjunction with the adhesive manufacturer's current Product Approval. Refer to the current version of the referenced Florida Product Approval for data,.. TILE ADHESIVES FOR ADHESIVE-SETTILE SYSTEMS Manufacturer Product s Florida Product Approval DAP Foam, Inc. 'Touch N' Seal Storm Bond" FL14506 'Touch N' Seal Storm Bond 2" FL21374 Dow Chemical 'TILE BOND"" FL22525 If-9 Adhe ken &,Sealants, inc- IPc k,;sa: ' AH 1:60,, F. Ln332. E.,cteriorResearch and Design, LLC. 712 R5 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 5: 10/1712017 Page 5 of 6 � f TRI I ; ERD 6.3.4 Hip and Ridge Tile: Tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge the installations atop hip and ridge meta), refer to th!e hip and ridge meta) manufacturer's current Product Approva) (e.g., FL5374) or test report in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12). 7. LABELING: 7.1 Each unit shall bear the imprint and /ior identifiable marking of the manufacturer's name or logo. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Autho lty Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Plant Profiles Okeechobee, F1 Bermuda Flat Plantation Flat Estate "S", B&j.1z. igh "S", Galena -Spanish "S' Ft. Myers, FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat, Hacienda, Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC.,—QUA9110; (813) 621-5777 - ENd OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-2-RS Certificate oJAuthorization 09503 6" EDITION (2017) FSC NON-FiVHZ EVALUATION FL7804-RIG Entegra Roof Ties Revision 5:10/17/2017 Page 6 of 6 Florida Building Code Online Page 1 of 2 SCANNED Lucie iCountt sZvn'�§ BQS Home i Log In User Registration Hot Topics i Submit Surcharge ' Slats & Facts i Publications ? FBC Staff BCIS Site Map i Links i Search Product Approval 01 -01E1: Public User ;. N Product AWroval Menu > Product or,Apptication Search �> Application Lisp > Application Detail FL # 4L6332-V1% Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer ICP Adhesives & Sealants, Inc. Address/Phone/Email 12505 NW 44th Street Coral Springs, FL 33065 ! (888) 774-1419 Ext201 i ryiipelkonen@icpadhesives.com Authorized Signature Riku Ylipelkonen rylipelkonen@icpadhesives.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roof Tile Adhesives Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 02/07/2021 Validated By John W. Knezevich, PE ✓ Validation Checklist - Hardcopy Received Certificate of Independence FL6332 R8 COI 2017 01 COI Nieminen.pdf Referenced Standard and Year (of Standard) Standard Year SSTD 11 1997 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D http://w-N,v-,v.floridabuilding.org/pr/pt_app_dt asp-%.? param=wGEVXQwtDquanCtKft6f°lo2f... 4/4/2018 Florida Building Code Online Page 2 of 2 Date Submitted 10/12/2017 Date Validated 10/14/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12,12017 Summary of Products FL # Model, Number or Name Description 6332.1 ICP Adhesives Polyset AH-160 Dual component expanding polyurethane roof tile adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL6332 R8 II 2017 10 FINAL ER ICP AH160 FL6332- R8. dfdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +n/a/-178 Created by Independent Third Party: Yes Other: 1.) The design pressure limitation in this application refers to hip and ridge tiles in one configuration, Refer to Evaluation Reports FL6332 R8 AE 2017 10 FINAL ER ICP AH160 FL6332- RB.pdf Created by Independent Third Party: Yes Table 2 of ER for all hip and ridge tile limitations. 2.) Field tiles are designed based on overturning moment resistance. Refer to Table 1 of ER for field tile limitations. 3.) Refer to ER Sections 5 for other Limitations of Use. Contact Us ::I 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850487-1824 The State of Florida is an AA/EEO employer. ,�vriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not %rant your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4S5, F.S. must provide the Department with an email address if they have one. The email$ provided may be used foC official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which an be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: inn rr;) Credit Care) Safe http://vww.flondabuilding.org/pr/pi_app_ il.aspx?param=wGEVXQwtDquanCtKft6t""%2f... 4/4/2018 TRIN1117v ERD EVALUA T ICON REPORT 1CP Adhesives and Sealants, Inc. 12505 NW 44th Street Coral Springs, FL 33065 (888) 774-1419 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT 13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report 02768.03.06-RE FL6332-R8 Date of Issuance: 08/08/2008 Revision 8:10/12/2017 SCOPE: I This Evaluation Deport is issued under Rule 61d120-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. ThiT documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: ICP Adhesives Polysetcl Ali-160 I LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COrv'IPUANCE. This Evaluation Report is iVand Jntrl Such tinge as the named productis% clTjng--5S. :-Q ref ra^� Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity(ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity ( ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be clone in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation- Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 T('_F-e,-simi e seaI Q==fiRU wds autho,!xe:d by Robcr t Nieminen, P.C. on 10/12/2017. This does not serve as an efectronicaflysiFneddocument. CERTIFiCATiON OF INDEPENDENCE: 2 Exterit-)r RpseatCh & Design, 1. C. d1b(a Trinity, I FRO does riot have, nor doe; i, Intend to acquire or will it acquire, a financial interest 'rn 2rrry WrirpaYry•rncfn*UiaZtcn'rrrbvUt IMAt"?acrcrcA adrurdtc�. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company aanufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is ? building cirliP (wifluation. Neither Trinity) t Ri s?ar Z,;I?eft r.E. af'r3, iz: :ay rvvay, rho Desigaer -f Record or an}, project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Roomic. COMPONENT EVAI_UATIm, 1. SCOPE: Product Category: Roofing Sub -Category: Roof Tile Adhesives Compliance Statement: ICP Adhesives PolysetO AM-160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance vilth the 6trEdition; (2017) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is slut jest to the installation Requirements and Limitations, Conditions of Use set forth herein. 2. STANDARDS: Sections Proper Standard Year 1504.2.1.1 Overturning, es stance 5STD 11 1997 3. REFERENCES: Entity &arniriatfon Reference Date ERD (TST6049) Static Uplift-SSTD 11 P39740.02.12 02/20/2012 ERD (TST 6049) Static Uplift—SSTD 11 P39740.11.13-131 01102/2015 ICC-ES (EVL2396) 2012 IBC Compliance ESR-1709 12/01/2016 Miami -Dade (CER 1592) HVHZ compliance 17-0322.03 04/27/2017 PRI (TST 5878) Static Uplift—SSTD 11 ECM-001-02-01 09/21/2001 PRI (TST 5878) Static Uplift — S_ISTD 11 PFI-006-02-01 05/09/2005 PRI (TST 5878) Static Uplift—SSTD 11 PFP-006-02 n2 051109/2.005 PRI (TST5878) Static Uplift—SSTD 11 PH-007-02-01 10/11/2005 PRI (TST 5878) Static Uplift —SSTD 11 PFI-008-02-04 02/21/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFI-009-02-03 02/21/2006 PRI (TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-010-02-01 12/07/2006 PRI (TST 5878) Static Uplift —SISTD 11 PFPI-011-02-01 12/07/2006 PRI (TST 5878) Static Uplift — SSTD 11 PFPi-012-02-01 12/07/2006 PRI (TST 5878) Static Uplift— 56TD 11 PFP(-018,02-01 12/07/2006 PRI (TST 58781 Static Uplift— SSTD 11 PFPI-014-02-01 12107/2006 PRI (TST 5878) 1Static Uplift—SSTD 11 ECM-003-02-01 06/13/2008 PRI (TST 5878) Static Uplift— SSTD 11 ECM-004-02-01 06/13/2008 PRI (TST 5878) Static Uplift— SSTD 11 ECM-005-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM-006-02-01 06,/1-4/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM-007-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-008-02-01 06/13/2008 UL LLC (QUA 9625) Quality Assurance Service Confirmation Exp. 0610512013 4. PRODUCT DESCRIPTION: 4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding. polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available in refillable tanks or disposable cylinders (ICI' Adhesives ProPacl:'! 30 & 100). S. e ififllT zoivs: 5.1 T,his ss a tisitding cede evaluation. Neithe Trinity(ERD nor Robert iNierninen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. Ex�edor Research and Design, LC. Evaivation'Report 132758.133 t S-R& L2rhYrare ofAutharkarion #YS03 6' EDMON (2017) FSC NON-HVHZ EVALUAT10N FL6332-R8 ICP Adhesives'PoIVset1' AH-160: (989) 774-1419 Revision 8:10/12/2017 Page 2 of 9 TRINITY : E D 5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this product and FBC 1505.2. 5.4 ICP Adhesives Polyset® AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.5 Minimum underlayment shall be peer FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives Polyset® AH-160. 5.6 cietd fifes, tneef1trg the t[mikauoos tiT Eac Lisag s,:a, 4.LsinZ iCP Adhesives Pniyseto XK-1650 are limited to projects having an Aerodynamic Uplift Moment (M.), determined in accordance with FBC 1609.5.3 or Tables 2A and 2B of FRSA/TRI April 2012 504-12), not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TALE 1: F�ELD TILES ir4 ICP ADHESIVES POLyScT� AH-160 ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA _ '. .2It71NrffRGMCOFSRFEIYHLREHOYFF.'PUL77 FDRlSODEPtl4YJElYf(Sl79GLEOtrCU10'RWr70USYitUfri"%YL'Rtt7VltNf 4-T0.'�MAR6/NOF5AFE7YALREADY,APPVED FOR INTERDEPENDENT.(TWOPADDY) :�PLACEMENT ' -� Tile (FBC 1609.5.3) Adhesive Paddy Placement Allowable overturning Type Profile I Moment (ft-lbf) Independent; Single Paddy, Medium (2x7-inch, -30 gram) 60 Clay Fiat Independent; Single Paddy, Large (2x10-inch, -45 gram) 112 Concrete interdependent; ,wo Paddy (4x4-inch on underlayment, 2x4-inch attile overlap) 54 Independent; Single Paddy, Medium (2x7-inch, ^30 gram) 39 Clayor Low/ Independent; Single Paddy, Large (2x10-inch, -54 gram) 67 Concrete Medium Interdependent;ITwo Paddy (44-inch on underlayment 2x4-inch at tile overlap) 58 Clay High Independent; Si�gle Paddy, Large (WO -inch, -45 gram) 134 Independent; Si{ gle Paddy, Medium (2x7-inch, -3D gram) 65 Clayor High Independent; Si gle Paddy, Large (2x10-inch, -63 grain) 109 Concrete Interdependent; tpvo Paddy (4x4-inch on underlaymen4 2x4-inch at the overlap) 40 Clay Barrel 2x10-inch x-35 gram for pans; 2 @ 1x10-inch x -17 gram for cap 147 Concrete Barrel 2x10-inch x ^35 gram for pans; 2 @ 1x10-inch x-17 gram for cap 107 Clay Cap atop 2x independent: Cqntinuous Paddy (^34 gram/ft) 135 stringer I Concrete Capp 2x a independent: Continuous Paddy (-34 116 at strCta gram/ft) �r , Cap atop 2x Interdependent: 1a5 stringer Head: One (1) #10 x 2%" screw; Overlap: 1 x 6 inch (-10.5 gram) Concrete Cap atop 2x Interdependent: . I 76 stringer Head: One (1) #10 x 2W' screw; Overlap: 1 x 6 inch (-10.5 gram) 5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRl April 2012 (0442). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP Adhesives Poiyset4 A14-160. 5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning moment'. Exterior Research and Design, LLC. e'vaiva;fott Report 0276E.03.06-R8 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-118 ICP Adhesives Polyseto AH-160; (888) 774-1419 Revision 8:1011212017 Page 3 of 9 TRINITY�� 5.7 Hip and ridge tiles using ICP Adhesives PolysetO AN-160 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA,TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesi i es and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 2: Hip &iR@GETILES W ICP ADHESIVES" POLySE'rm 41i-160 " ALLowAdLE UPLIFT RESISTANCE PERFORMANCE DATA 2 To 1 MARGIN OF SAFETY ALREADYAPPVED FOR INDEPENDENT-f CONTINUOUS PADDY) PLACEMENT . 4 TO 1 MARGIN OF SAF_F"e VAI READYAPPOED FOR INTERVEPS46ENr?LACE7V su— Allowable Tile Substrate Attachment Method Design Pressure (psf) Clay 2x PT ridge board Independent: Continuous Paddy (-34 gram/ft) 116 Concrete 2x PT ridge board Independent: Continuous Paddy (- 34 gram/ft) 107 Clay 2x PT ridge board Interdependent: Head: One (1) #10 x 2/:" screw; 90 Overlap: 1 x 6 inch 1-10.5 gram) canuete 2xPT xidge baasd Interdependent: !lead: One (1) €t10 x 2/" screw; 56 Overlap: 1 x 6 inch (-10.5 gram) Clay or Hip & Ridge Channel Metal (FL5374): Independent: Continuous Paddy (^34 gram/ft) 169 Concrete galvanized only Clay or Trim LockM (FL5374): alutninu4 Independent: Continuous Paddy {�34 gramJft) 173 Concrete galvanized, GalvalumeO or stainless steel Clay or Trim Lock- Plus (FL5374): aiurriinu:n, Independent: Continuous Paddy (� 34 bramJfi) 278 Concrete galvanized, Galvalurne", orstainlless steel i Clay I Top Notch (FL8095) Independent: Continuous Paddy 32 gram/ft) 125 Concrete Top Notch (FL8095) Independent: Continuous Paddy 32 gram/ft) 146 6. INSTALLATION: 6.1 ICP Adhesives PolysetO AH-160 and the tile roof assembly shall be installed in accordance with FRSA%TRI April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the limitations outlined in Section 5. 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc. � 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Tomball, TX 9. QUALITy ASSURANCE ENTITY: UL, LLC.-QUA9625; (847) 664-3623; LeAnna.Gracleckl@u1.corn i Exterior Research and Design, LLC. Evaluation Report 02768.03.06-RR Certificate ofAuthorizodan #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-118 ICP Adhesives PolysetO AH-150; (888) 774-1419 Revision 9:10/12/2017 Page 4 of 9 i TRIN@per®qy ERD 10. PADDY PLACEMENT OF -TAILS (FROM St=P'AoKESws AND SEALANTS, INC. PUBLISHED LITERATURE)' 10.1 Independent, Medium Paddy: Flax/Low ProfileTile. Exterior Research and Design, LLC. Certificate oJAathorization #9503 Nall through plastic cement (when required) Paddy (Beneath Tile) Und?rlaymenx �_ r t2in. Battens optional I ��-- EaveClosure Save Course �,: f` f —Fascia High Profile Tile i 6- EDITION (2017) FBC NON-HVHZ EVALUATION ICP Adhesives Polyse , AH-160, 1989) 774-1419 I I � Medium ProfileTile Evaluation Report 02768.03.06-RS FL6332-R8 Revision 8:10f 12f 2017 Page 5 of 9 Independent, Large PaddV: High ProfileTile f Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-RS Certificate of Authorization 99503 6n1 EDITION (2017) F6C NON-HVHZ EVALUATION FL6332-RS ICP Adhesives Poh/seV AH-160; (888) 774-1419 Revision 8:1011212017 Page 6 of 9 Lj 10.3 Interdependent, Two PaddV: Flat/Low Profile Tile Exterior Research and Design, I.I.C. Certificate of Authorization #9503 it through plastic cetnent hen required) [tens L al ion, Z S S(nqfv paddy ontop ofthe ¢4x4in. Caddy on High Profile Tile 6' EDITION 2017) FBC NON-HVHZ EVALUATION ICP Adhesives Polyset) AH-160; (898)774-1419 TRINITY, ERD Paddy under the Paddy (between tiles) iJ Paddy (under tile) 0 Fascia Medium ProfileTile Evaluation Report 02768.03.05-118 FL6332-R8 Revision S; 10]1212017 Page 7 of 9 TRINITY, ER D 10.4 Two Piece Barrel (Cap & Pan) Tiler 11 Place enough adhesive to achieve 65 to 7(l in contact with the pan tile. 2) Turn Covers upside down. Place adhaDh-c 112 in. to 1 Inch in from qulside edge of cover tile. Install cover lllr.. Ensure 20 to 25 sq. in. contact area anI cacti side of comr hle.l Underlayment �• , i �'P� 10.5 Steep pitch applications (when required) (motarshown)�� t":aephoie'`� � Fascia Bloard Remove top portion of the eave course cover tile.Abut to second course of pan tiles. Ensure eaveiend of pan and cover tiles are Flush at eave line. Twoj Piece Barrel -High Profile Tile Abtad.=PPc4}":e17tAi{-ihdmaIt+v.11pSMwo-. da^1't!'ri 'fo::it:*aE�L:i:-:i:=v.'y at��"b!'e:9f:si:•c_St?11{.!!sir,_•s1 fit. i%!zi 0 .7 : d:', ; : xrtl Qr z.+�ti:.".8: . • ;ypb M Ary:.'i` ('E' iz w r.v!l :SCR i7.'i t' ;'i4uJ _,r _i.ai 11"o frame to provide ealhrltaac sm fr+me. Exterior Research and Design, I.I.C. i Evaluation Report 02768.03.06-RB Certificate of Authorization #9303 6m EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset° AH-160; 1888) 774-1419 Revision 8:1011212017 Page 8 of 9 10.6 Nip and Ridge (interdependent placements: EVALUATION REPORT- Exterior Research and Design, LLC. Evaluation Report 02768.03.06-RS Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-RS ICP Adhesives PolysetO AH-160; (888) 774-1419 Revision 8:10112/2017 Page 9 of 9 Florida Building Code Online Page 1 of 3 SCI5 Homes I Log In I User Registration Product Approval USER: Public User RMudAoor=al racy > FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative address/Phone/Email Category Subcategory Compliance Method SCANNED BY _ St Lude COUnt/ { SWxWt Surcharge I Stats & Fads { Publkatlans i Fac staff { aCIS Site Map I Links I Search Sit > d4Wlcatlan Ust > Appltcatlan OOrall FL9777-R11 Revision 2017 Approved ❑i Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscornIng.com Greg Keeler greg.keeler@owenscorning.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report- Hardoopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report I Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date LZ(31/2020 Validated By Locke Bowden P.E. ® Validation Checklist - Hardcopy Received Certificate of Independence FI 97T( all COI_OL'R14002 8a 2017 FBG Evaluation Reeort Weatherlack Non-HVHZ.odf Referenced Standard and Year (of Standard) Standard Year ASTM D 1970 2015 ASTM D 226 2009 ASTM G 155 2005 TAS 103 1995 UL 1897 20L2 Equivalence of Product Standards Certified By Sections from the Code i I https://www.floridabuilding.org/pr/pr app_4tl.aspx?param=wGEVXQwtDgtgkcMGblcW7... 5/16/2018 Florida Building Code Online Page 2 of 3 Product Approval Method Method 1 Option D Date Submitted 10/11/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/17/2017 Date Approved 1V12/2017 Summary of Products PL # Model, Number or Name Description. 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use installation Instructions Approved for use In HVHZ: No FL9777 R11 11 0CR140Q2.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.odF Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Others See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report Watbe lode Non-HVHZ.odf Created by Independent Third Party: Yes 9777.2 WeatherLocklG (High Tear) Weatherproofing Underlayment Limits of Use I Installation Instructions Approved for use in HVHZ: No FL9777 1111 11 OCR14002.83 2017 FBC Evaluation Reoort Weathercock Non-HVHZ.ndf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other. See evaluation report for limits of use. Evaluation Reports FL9777 RI AE OCR14002.88a 2017 FBC Evaluation Renort Non-HVHZ.odf Matherio Created by Independent Third Party: Yes 9777.3 Weatherlock MAT Waterproofing Underlayment Limits of use Installation Instructions Approved for use in HVHZ: Yes FL977Z RSl 1I OCR14002.8h 2017 FBC Evaluation Report Weatherc%k HVHZ.odf Approved for use outside HVHZ: No Impact Resistant N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report For limits of use. Evaluation Reports EL9777 III AE OCR14002.8b 2017 FBC Evaluation Renort Weathercock HVHZ.odf Created by Independent Third Party: Yes 9777.4 WeatheriocklMAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use In HVHZ: No Fi4777 RII II OCRI4002.8a 2017 FBC Evaluation Sgggft Weatherlaek Non-HVHZ.odf Verified By: Zachary R. Priest 74022 Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A other: See evaluation report far limits of use. Created by Independent Third Party: Yes Evaluation Reports EL9777 1111 AE OCRi4002.8a 2017 FBC Evaluation Reap Weathercock Non-HVHZ.pdf Created by Independent Third Party: Yes 9777.5 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use In HVHZs No FL9777 1111 11 OCR14002.8a 2017 FBC Evaluation gg= Approved for use outside HVHZ: Yes Weatherlack Non-HVHZ.odf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports Created by Independent Third Party: Yes 9777.E Weatherl-ock Metal Weatherproofing Underlayment Limits of use Installation Instructions Approved for use in HVHZ: Yes FL9777 Rii lr OCR14002.8b 2017 FB val uallo_ n Report Approved for use outside HVHZ: No Weatherlock HVHZ.odf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design pressures N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports 111 .86 2017 FBC Evaluation https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtgkcMGbieW7,,, 5/16/2018 Florida Building Code Online Page 3 of 3 Weatherlack HVH_Z.odf Created by Independent Third Party: Yes ?77 . Weath rL cae k,Specialty Tile & Metal Weatherproofing underlayment :units of Use Approved for use In HVHZs No Ye Approved for use outside HVHZ:s Installation Instructions FL9777 Ril 11 OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.odf Impact Resistant.. N/A Verified By: Zachary R, Priest 74021 Design Pressurea +0/-142.5 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL977] R11 AE 0CR14002.2p 2Q17 FBC Evaluation Report WeatherlogN Non- V Created by Independent Third Party: Yes each Contact WA :: 2601 Blair Stone Read. Tallahassee FL 3RS99 Phone; BSGAIZ-1821 The State of Flodda Is an AA/EED employer.! Convrloht 2pp7-2013 Aceesslblllty Statement :: Refund Statement Under Florida law, ema9 addresses are public records. If you do not want your e-mail address released In response to a publk•recards request, do not Sand elocbonk mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.139S. *Pursuant to Section 455.275(1), Florida Statutes, effectiveOctober 1, 2012, Ikensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The amails provided may be used for official communization with the licensee. Howerer emall addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please dick hm , Product Approval Accoptsi r6dit Gard a https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtgkcMGblcW7... 5/16/2018 CREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Manufacturer: Manufacturing Location: Quality Assurance: SCOPE Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 FLORIDA BUILDING CODE, a EDI11ON (2017) OWENS CORNING ROOFING AND ASPHALT LLC 1 Owens Corning Parkway . Toledo, OH 43657 (800) 438-7465 Brentwood, NH Houston, TX UL LLC Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties REFERENCES E tit � issued October 11, 2017 PRI Construction Materials Technologies (TST5878) NEI-03399.02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) NEI-042-02-01 REV2 ASTM D 1970 2016 PRI Construction Materials Technologies (TST5878) NEI-045.02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) NEI-045.02-01 ASTM G 165 2005a PRI Construction Materials Technologies (TST5878) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) NEI-093.02-02 ASTM D 1970 2015 PRI Constructlon Materials Technologies (TST5878) 0CF-213-02-01 ASTM D 1623 2009 PRI Construdlon Materials Technologies (TST5878) OCF-237-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-253-02-02 ASTM D 1970 2016 PRI Construction Materials Technologies (TST5878) OCF-272-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) OCF-296-02-02 ICC-ES AC 188' 2012 ICC-ES AC 48 2012 PRI Construction Materials Technologies {TST5878) OCF-297-02-01,1 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-318-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) OCF-321-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST5878) CCF-322-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST5878) OCF,355-02-01 UL 1897 2012 'Determined to be equivalent to ASTM D 226.09, Type I and 11 OCR14002.8a This evaluation report is provided for State of Florida product approval under Rule 61G20.3. The manufbcturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughput the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND LIMITS OF USE OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers WeatherLock® G WeatherLock® G Is an ASTM D 1970 self-adhesive underlayment constructed from SBS (Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied lin 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLockO G Is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock® Mat Weetherl-oclk® Mat is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- Houston, TX) sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. 1 WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days WeatherLock® Metal WeatherLock® Metal is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® Metal Is permitted to be used as prescribed In FBC Section 1607.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days'. I WeatherLock@ WeatherLock® Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tfle & Metal constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric. (Brentwood, NH or The product is supplied In 2.14 sq, rolls with nominal dimensions of 3-ft x 71.3-ft. Houston, TX) WeatherLock® Specialty Tile & Metal Is permitted to be used as prescribed in FBC Section 1507.1.1.1 WeatherLockQD Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICI? Adhesives and Sealants, Inc.) or TILE BONCm Roof 'Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock® G (High WeatherLock® GI(High Tear) Is a self -adhered, underlayment used as an alternative to Tear) ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer (Houston, 7X) modified bitumen;underlayment. The underlayment Is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and Is surfaced with granules. The product is supplied with a nominal thickness of 50 mlls in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. Weatherl-ockO G (High Tear) is permitted to be used as prescribed In FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.8a FL9777-R11 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shelf notify CREEK Technical Senrices, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK OWENS CORNING ROOFING AND ASPHALT LLC Weatherl-ockD Setf-Seating Ice & Water Barriers TECHNICAL SERVICES, LLC PRODUCT APPLICATION Min. Roof Slope: 2:12 In accordance with the FBC Application: All underlayments I hall be installed in accordance with me FBC. Deck substrates shall be clean, dry, and free from any tnegulariftes and debris. A# fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning Installation, the undedayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlaymentlshall be installed with the release backer removed and pressed thinly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the save, starting at the eave, and with minimum 3" side laps and minimurrj 6" end laps staggered min. 64from preceding course. Additionally, If applying WeatherLock@ Specialty Tile &,Metal, end laps shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 Inches across the width of the lap. It is permissible to back nail the undedayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Additionally, WeatherLock@ Specialty Tile & Metal shall be back nailed when installed on Iroof slopes greater than 3:12. Min. Application 40°F; Contact thel manufacturer when instaft at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No.1 — Weatherl-ock SpecialtyTile & Metal Only Roof Deck: Min. 15/32-Inch CDX plywood attached to wood supports spaced a maximum 24" o.m Undedayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnalled along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1-5/8-Inch 0 tin caps spaced 12" o.c. The applied undedayment shall be rolled with a minimum 751b steel roller Immediately following application. Maximum Design -142.5 psf Pressure: OCR14002.8a FL9777-Rll 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20,3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TRCHNICAL SERVICES, LLC GENERAL LIMITATIONS OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock(D Self -Seating Ice & Water Barriers 1) This evaluation report is not use in the'HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions.' Where discrepancies exist between these sources, the more restrictive and FBC compliant Installation detail shall prevail. 4) The roof deck shalt be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall tie properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed toy shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding In accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a ;given underlayment shall most or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code dh Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. `,, srstrtrrr����, No 74021 r � STATE OF i0i�•.•A i ......•' Cam` �,'SS,ONA, ti��0,• CERTIFICATION OF INDEPENDENCE 09:06:29 04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9841 CREEK Technical Services, LLC does not have, nor will it acquire, a 11nanclal Interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14002.8a FL9777-R11 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Flonda.Building Code Online Page 1 of 2 � �,. T.� '��� i' � ��. SCANNED i r r. �tt BQS Home i Log In i User Registration 4 Hot Topics I Sub 1 h ei Publications ;�FBC State i BCIS Site Map Unks Search "4r t fi� Product Approval 13! USER: Public User 2. it Product Aooroval Menu > eroduct oDlication Search > implication L st > Application Detail FL # FL5374 RS ` Application Type Affirmation Code Version 2017 Application Status Approved Comments Archived 0 Product Manufacturer East Coast Metals, Inc. Address/Phone/Email 2301 West 8 Lane Hialeah, FL 33010 (305) 885-9991 I acastellanos@eastcoast-metals.com Authorized Signature Tom Castellanos i acastellanos@eastcoast-metals.com I technical Representative Tom Castellanos Address/Phone/Email 2301 West 8 Lane Hialeah, FL 33010 (305)885-9991 tcastellanos@eastcoast-metals.com Quality Assurance Representative Howard Callender Jr. Address/Phone/Email 2301 West 8 Lane Hialeah, FL 33010 (305)885-9991 hca (lender@eastcoast-metals.com Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer - Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who; developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Robert Nieminen PE-59166 Architectural Testing, Inc., an Intertek company 12/31/2018 John W. Knezevich, PE 13 Validation Checklist - Hardcopy Received FL5374 R5 COI 2015 O1 COI Nieminen Ddf Standard Year FRSA/TRI April 2012 (04-12) 2012 RAS 118 1995 RAS 119 1995 RAS 120 1995 SBCCI SSTD 11 1997 TAS 101 1995 http://www.floridabuilding.org/prlpi_app_dtl.aspx?param=wGEVXQwtDgtVSv8n7ODFXf... 5/ 17/2018 Monda Building Code Online ! J Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code ''MiI affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity "'Yes -::.,No ` IN/A FL5374 R5 COC 2017 09 AFFIRMATION ECM FL5374 6th Edition (2017).pdf I Product Approval Method Method 1 Option D Date Submitted 09/06/2017 Date Validated 09/06/2017 Date Pending FBC Approval Date Approved I 09/10/2017 Summary of Products FL # Model, Number or Name Description 5374.1 East Coast Metals Channel Metals Preformed metal channels designed for use as a hip & ridge base to which roof tiles are bonded. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5374 RS II 2015 03 FINAL ER ECM Trim Approved for use outside HVHZ: Yes Lock FL5374-R4. ddf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-178 Created by Independent Third Party: Yes Other: 1.) Refer to Evaluation Report Sections 5.2 and 5.3 Evaluation Reports for Limits of Use in HVHZ and non-HVHZ jurisdictions, FL5374 R5 AE 2015 03 FINAL ER ECM Trim respectively. 2.) The design pressure herein pertains to use Lock_ FL5374-R4.Ddf In non-HVHZ jurisdictions in conjunction with Table 3A of Created by Independent Third Party: Yes FRSA/TRI April 2012 (04-12). Refer to Tables 2A and 2B In the Evaluation Report for all options and associated allowable design pressures. back rdext Contact Us :: 2601 Blair Stone Road. Tallahassee 32399 Phone: 850-487-1824 ' The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, FS., please click here , Product Approval Accepts: Credit Card .Safe http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGE VXQwtDgtVSv8n7ODFXf... 5/17/2018 ti RINITY I ERD EVALUATION REPORT East Coast Metals, Inc. 2301 West 8 Lane Hialeah, FL 33010 EXTERIOR RESEARCH & DESIGN, LLC. Certificate ofAuthorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report E10240.08.08-R4 FL5374-R4 Date of Issuance: 09/03/2008 Revision 4: 03/17/2015 SCOPE: I This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 15th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: East Coast Metals Channel Metals I LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: �; ;';� .+� r The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M. Nieminen, P.E. fi c Florida Re istration No. 59166, Florida DCA ANE1983 �yFu^^'� �, ., P.E. on 03f17/2015. This does not serve as an electronically signed 9 1,,.�. L t 0 document. Signed, seated hardcopies have been transmitted to the dig:ruwna� Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity] ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 1 TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subjectto the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property i Standard Year 1507.3.7 Installation, non-HVHZ FRSA/TRI April 2012 (04-12) 2012 1518.8.1 Installation, HVHZ RAS 118,119 & 120 1995 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 1711.2.1 Static Uplift Resistance SBCCI SSTD 11 1997 3. REFERENCES: i Entity Examination Reference Date ERD (TST6049) Static Uplift Resistance E42730.08.13 08/23/2013 ERD (TST6049) Static Uplift Resistance ECM-SC6795.12.14-1 02/27/2015 ERD (TST6049) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2015 Florida TEC (TST7393) TAS 101 S10-628R 10/27/2010 PRI (TST5878) TAS 101 ECM-001-02-01 09/21/2001 PRI (TST5878) TAS 101 ECM-003-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-004-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-005-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-006-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-007-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-008-02-01 06/13/2008 Florida Building Code Attachment Requirements FRSA/TRI April 2012 (04-12) 04/2012 Florida Building Code - HVHZ Attachment Requirements RAS 118, 119 and 120 1995 East Coast Metals Metal Quality Mill Certifications Various Architectural Testing (QUA1844) Quality Control Participation Letter Exp. 12/31/2018 4. PRODUCT DESCRIPTION: 4.1 Hip & Ridge Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Hip & Ridge Channel Metal is available in 119-3/8-inch (± 3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch (± 3/8-inch) heights with 1.5-inch (± 1/16-inch) deck -flanges. Exterior Research and Design, LLC. Certificate of Authorization 09503 Evaluation Report E10240.08.08-R4 FL5374-R4 Revision 4: 03/17/2015 Page 2 of 7 \"]'T'�'_�INITYIERD 4.2 Trim Lock Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Trim Lock Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive. i Trim Lock Channel Metal is available in 119-3/8-inch (± 3/8") length by 3, 3.5, 4, 5 or 6-inch (±i 3/8-inch) heights with 1.5-inch (±1/16-inch) deck -flanges., 4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof the adhesive. Trim Lock Plus Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive and its perforated deck flanges, designed for installation atop the roof underlayment via placement in FBC Approved roof tile adhesive, which flows -through and interlocks with the underlying adhesive Trim Lock Plus Channel Metal is available in 119-3/8-inch (±3/8") length by 3, 3.5, 4, 5 or 6-inch (±3/8-inch) heights with 1.5-inch (± 1/16-inch) deck -flanges. 4.4 East Coast Metals Channel Metals are fabricated of the following metals: ➢ Galvanized Steel: Min. 0.019 ±0.002-inch, ASTM A653 (G-90), min. 33 KSI. ➢ Galvalume Steel: Min. 0.019 ±0.002-inch, ASTM A792, AZ55, min. 35 KSI. ➢ Aluminum: Min. 0.032 ±0.002-inch, ASTM B209; 3003-H14, min. 21 KSI. ➢ Stainless Steel: Min. 0.019 ±0.002-inch, ASTM A240/A480, T304, min. 35 KSI. 5. LiMiTATioNs: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Exterior Research and Design, LLC. Evaluation Report E10240.08.08-R4 Certificate oJAuthorization #003 FL5374-114 Revision 4: 03/17/2015 Page 3 of 7 � TRINITY I ER® I 5.2 FOR HVHZJURISDICTIONS: 5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation instructions herein. 1 5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and 120, and the data in Tables 1A and 1B is supplemental to these prescriptive allowances. Installations of Trim Lock Plus are limited to projects having a required moment resistance (Mr) or uplift resistance (Fr), as determined in accordance with RAS 127, not greater than the following values. Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details. ➢ "INDEPENDENT" paddy placement' means each individual tile is bonded to the Channel Metal in its own, single foam paddy; tile head laps are :not bonded. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLE.Z14 PERFORNIANCEUMITATiDNS'HVHZ,INDEPENDENTPADDYP.LACEMENT -„(2To,1MARGINOFSAF#YALRFADYAPPCIEDl Hip/Ridge Metal rile Adhesive Allowable Performance Design g Metal Type yp Type Placement Moment Based Uplift Based MI(ft-lbf) F' (Ibf) Hip & Ridge galvanized g clay or 3M' 2-Component Foam Independent 127 169 Channel Metal concrete Roof Tile Adhesive AH-160 Trim Lock galvanized, Galvalume", clay or 3M' 2-Component Foam independent 171 159 aluminum or stainless steel concrete ' Roof Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalume°, clay or 3M— 2-Component Foam Independent 177 165 aluminum or stainless steel concrete Roof Tile Adhesive AH-160 TABLE 1B PERFORMANCE LI "RATIONS HUHZ, INTERDEPENDENT PAbbY;PLACEMENT t ; �Q TOZMARQIAlOF¢AFEIY-AtREA1)YAPPtlED�_,` Hip/Ridge Metal Tile Adhesive Allowable Performance Design Metal Type Type Placement Moment Based Uplift Based Mf (ft Ibf) F' (lbf) Trim Lock or Trim galvanized, Galvalumem, clay or 3M— 2-Component Foam Lock Plus aluminum or stainless steel concrete Roof Tile Adhesive AH-160 Interdependent 95 88 Trim Lock galvanized, Galvalume°, clay or 3M— Roof Tile Adhesive Interdependent 99 94 stainless steel concrete RTA-1 Trim Lock aluminum clay or 3MTM Foam Roof Tile Interdependent 90 84 concrete Adhesive RTA-1 Trim Lock Plus galvanized, Galvalume®, clay or 3M— Foam Roof Tile Interdependent 90 84 aluminum or stainless steel concrete Adhesive RTA-1 Trim Lock galvanized, Galvalume° or clay or TILE BOND"' Roof Tile stainless steel concrete Adhesive Interdependent 123 117 Trim Lock aluminum clay or TILE BOND" Roof Tile Interdependent 79 73 concrete Adhesive Trim Lock Plus galvanized, Galvalume°, clay or TILE BOND" Roof Tile Interdependent 79 73 aluminum or stainless steel concrete Adhesive Trim Lock galvanized, Galvalume° or clay or Touch'n Seal Storm Bond stainless steel concrete Roof Tile Adhesive Interdependent 146 139 Trim Lock Aluminum clay or Touch'n Seal Storm Bond Interdependent 58 54 concrete Roof Tile Adhesive Trim Lock Plus galvanized, Galvalumem, clay or Touch'n Seal StormBond Interdependent 58 54 aluminum or stainless steel concrete Roof Tile Adhesive Exterior Research and Design, I.I.C. Evaluation Report E30240.08.08-R4 Certificate of Authorization #9303 FL5374•R4 Revision 4: 03/17/2015 Page 4 of 7 TRIM' j ERD 5.3 FOR NON-HVHZJURISDICTIONS: 5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus Channel Metal, refer to the installation instructions herein 5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details. ➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy; tile head laps are not bonded. This method is limited to 2-parttile adhesives. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. ➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLE2A .PERFORMANCELIMRA7IONS NON�IVHZrINDEPENDENTPADDYPtACEMENT i ;• . •- ' - _ - MAg6jA10 SAFE7YALREgDYAPP_L!_EDf Hip/Ridge Metal Tile Adhesive Adhesive Uplift (pso Design n Meta1T a Type Type Placement Hip & Ridge g alvanized clay or 3MT" 2-Component Foam Roof Independent 169 Channel Metal concrete Tile Adhesive AH-160 Trim Lock galvanized, Galvalume°, aluminum or clay or 3MT" 2-Component Foam Roof Independent 173 stainless steel concrete Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalume®, aluminum or clay or 310P" 2-Component Foam Roof Independent 178 stainless steel cohcrete Tile Adhesive AH-160 "' TABLE26 PERFORMANCELimrrA ONS NON H!/HZ INTERDEPENDENT PADDYPLACEiV1ENT, - oTOIMA$GINOFSAFE7YALREADYAPPLIED�:;" t Hip/Ridge Metal Tile Adhesive Allowable Uplift (Ps f) n Desi g MetalT a Yp Type Placement Trim Lock or Trim galvanized, Galvalume°, aluminum or clay or 3MT" 2-Component Foam Roof Lock Plus stainless steel concrete Tile Adhesive AH-160 Interdependent 98 Trim Lock galvanized, Galvalume° or stainless clay or 3MT" Foam RoofTile Adhesive steel concrete RTA-1 Interdependent 110 Trim Lock aluminum clay or 3MT" Foam Roof Tile Adhesive Interdependent 93 concrete RTA-1 Trim Lock Plus galvanized, Galvalume°, aluminum or clay or 3MT" Foam RoofTile Adhesive stainless steel concrete RTA-1 Interdependent 93 Trim Lock galvanized, Galvalume° or stainless clay or TILE BOND— RoofTile Adhesive Interdependent 152 steel concrete Trim Lock aluminum or TILE BOND" RoofTile Adhesive Interdependent 82 concrete te Trim Lock Plus galvanized, Galvalume°, aluminum or clay or TILE BOND" RoofTile Adhesive Interdependent 82 stainless steel concrete Trim Lock galvanized, Galvalume° or stainless clay or Touch'n Seal Storm Bond Roof steel concrete Tile Adhesive Interdependent 148 Trim Lock Aluminum clay or Touch'n Seal Storm Bond Roof Interdependent 61 concrete Tile Adhesive Trim Lock Plus galvanized, Galvalume°, aluminum or clay or Touch'n Seal StormBond Roof stainless steel concrete Tile Adhesive Interdependent 61 Exterior Research and Design, I.I.C. Evaluation Report E10240.08.08-R4 Certificate oJAuthoriration 49503 FL5374-R4 Revision 4: 03/17/2015 Page 5 of 7 TRINITY ER® 6. INSTALLATION: 6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in accordance with FBC Chapter 23 to the satisfaction of the AHJ. 6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1%-inch long x 3/8-inch head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be positioned %-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. 6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons of tile adhesive centered beneath each 1:5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet adhesive and allow it to set-up prior to installation of roof tiles. View of Polyset AH260 Placement for Trim Lock Plus Channel Metal Installation 6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not disturbed prior to or during placement ofthe ridge tiles. 6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved use of the subject tile adhesive. Exterior Research and Design, LLC. Evaluation Report E10240.08.08-R4 Certificate ofAuthorkation #9503 FL5374-R4 Revision 4: 03/17/2015 Page 6 of 7 TRINITY I ER D 6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved, published installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS 118, RAS 119, RAS 120 requirements. Hip / Ridge Tile Tile Adhesive Trim Lock Plus Mortar or Weather Block Adhesive Tile Adhesive View of Trim Lock Plus Channel Metal Installation after Weather Blocked 6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Contactthe named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: Architectural Testing, Inc. — QUA1844; (717) 764-7700 - END, OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4 Certificate of Authorization #9503 FL5374-R4 Revision 4: 03/17/2015 Page 7 of 7