HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILESFlorida Building Code Online
Page 1 of 2
*+,bs
;. V I�
SCANNED
s.
LA
BY
St Lucie County l
�.
1 i
i FBC Staff BCIS Site Map i Links Search
BQS Home Log In User Registration ; Hot Topic I s ;
Submit Surcharge Stats & Facts
Publications
0,'TeProductApproval
USER: Public User
Product Approval Menu > Product of Application Search I> Applicatio Lis n Application Detail
Application Type
I Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Entegra Roof Tile, LLC
1289 NE 9th Avenue
Okeechobee, FL 34972
(602) 515-6933
thomas.jemmett@boral.com
Thomas Jemmett
tliomas.jemmett@boral.com
Roofing
Roofing Tiles
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name wh10 developed Robert Nieminen
the Evaluation Report
Florida license
Quality Assurance Entity
Quality Assurance Contract Expiration) Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
PE-59166
PRI Construction Materials Technologies, LLC
11/02/2018
John W. Knezevich, PE
J. Validation Checklist - Hardcopy Received
FL7804 R10 COI 2016 01 COI Nleminen.pdf
Standard
year
ASTM C1492
2003
FRSA/TRI April 2012
2012
SSTD 11
1997
TAS 100
1995
TAS 101
1995
TAS 102
1995
TAS 102(A)
1995
TAS 112
1995
httn://ww.floridabuilding,.org/pr/pr app
w_dtl.asp:c?paratn=,k&,GEVXQwtD±7uovojOMG/o2bA... 4/4/2019
Florida Building Code Online
Page 2of2
a �
Sections from the Code
I
Product Approval Method Method 1 Option D
Date Submitted
10/17/2017
Date Validated
10/19/2017
Date Pending FBC Approval
10/22/2017
Date Approved
12/12,1201-
I
Summary of Product.
FL #
Model, Number or Name
Description
17804.1
Entegra Concrete Roof Tiles (HVHZ
Concrete Roof Tile
jurisdictions)
I Limits of Use I Installation Instructions
i Approved for use in HVHZ: Yes FL7804_._R10- II__20L7__10 _FINAL ER__ENTEGRA__ FL7304
Approved for use outside HVHZ: No R10_ HVHZ,ptif
impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: NJA Created by Independentihird Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports
Section 6 for Installation. FL7804 R10 AE 2017 SO FINAL ER ENTEGRA FL7804-
R10 HVHZ.pdf
Created by Independent Third Party: Yes
r•--ter-- �re--•.
7804.2 t
1Egra Gdncrete Roof TIIes n n '
'Concrete Roof Tile
HUHZ,Iurisdlctio
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL7804 _RI,D II 2017 10 FINAL ER _ENTFGRAFL7804�
Approved for use outside HVHZ: Yes
R10 NON_HV�iZ.pdf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits,' of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7804 RIO AE 2017 10 FINAL ER ENTEGRA FL7804-
RIO NON-HVHZ.pdf
Created by Independent Third Party: Yes
Saclt Nc.
I
Contact Usl:: 2601 Blair Stone Road Tallahassee FL 3Z399 Phone: 950-497-1824
The Stale of Florida Is an AA/EEO employer. tyonvrioht 2007-2013 State of florida.:: Privacy Statement :: AttessibillN Statement :: Refund Statement
Under Florida law, email addresses are public relcords. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. `Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emaik provided may be used jfor official communication v6th the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, FS., please click here .
Product Approval Accepts:
Tfl 50 EtFri M
Credii. Card
Safe
-M f7 , i.
http: //wwav_fl or-i dabLiil ding. oi-gJpr/pr_app_dtl. aspx?parai7i=wGEVXQwtDquovoi OHI%2bA... 4/4/2018
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
ERD OXFORD, CT 06478
(203)262-9245
EVALUATION REPORT
i Entegra Roof Tile, LLC Evaluation Report E39310.11.11-2-R5
YNTEGRA 1289 NE 9th Avenue FL7804-R10
" e5l�. I ° ^ f.. i Okeechobee, FL 34972 Date of Issuance: 11/02/2011
(602) 515-6933 I Revision 5 :10/17/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated fir compliance with the a Edition (2017) Florida Building Code (non-
HVHZ) sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles (non- HVHZ jurisdictions)
LABELING: Labeling shall be in accordance vlitll the requires ens the Aer_sedlted Quavkt- AScLt53?lca 1�AP 1C\{ nt?t?�
herein. I
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
I
t�Sitt�Fc,YS�'IdiE14�: �Tre�rvdrerdi�rrtl'?� ,rri Trfrrn'rrc'f,FYIEL %>✓`'�'uy&tE!v�tertus"iTli7tt�YyE%3��diiiaiEtS" m-aVbedisplayedin
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59156, Florida DCA AIVE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10117/2017. This does not serve as an
electrortcally signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any —way, the Designer of Record for arty
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing I
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the 6`h Edition (2017) Florida Building Code through testing in accordance
with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of
Use set forth herein.
2. STANDARDS:
Section
Pro a I
Standard
Year
1507.3.5, R905.3.5
Physical Propertiesi
ASTM C1492
2003(2009)
1507.3.7, R905.3.7
Attachment Requi ements
FRSA/TRI April 2012 (04-12)
2012
1504.2.1.1
Overturning Moment
SSTD 11
1997
3" REFERENCES:
Entity
Examination
Reference
Date
ATL(TST3782)
Physical Properties
RT0615.01-11
06/28/2011
ATL(TST3782)
Physical Properties
RT0615.02-11
06/28/2011
ATL(TST3782)
PhysicalProperti6
RT0615.03-11
06/28/2011
ATL(TST3782)
Physical Properties
RT0615.04-11
06/28/2011
ATL(TST3782)
Physical Properties
RT0615.05-11
06/28/2011
ATL(TST3782)
Physical Properties
RT0316.01-12
05/31/2012
ATL (TST 3782)
Physical Properties
RT1103.01-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT2103.02-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.03-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.04-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.05-15
11/07/2015
PRI (TST5878)
Physical Properties
ESI-001-02-01
11/06/2006
PRI (TST5878)
Physical Properties
ESI-002-02-01
11/06/2006
PRI (TST5878)
Physical Properties
ESI-003-02-01
11/06/2006
PRI (TST5878)
Physical Properties
ESI-004-02-01
11/06/2006
PRI (T5-T3878)
Trhysical Properties
1 51-0U3-02-01
12117112006
PRI (TST5878)
Physical Properties
HRT-023-02-01
11/19/2007
PRI (TST5878)
Physical Properties
HRT-026-02-01
01/08/2008
Tile Roof Institute
SSTD 11 1Membership
Confirmation
Current
PRI (QUA9110)
Quality Assurance
I
Service Confirmation
Exp. 11/02/2018
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-2-R5
Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 5: 10/17/2017
Page 2 of 6
4. PRODUCT DESCRIPTION:
4.1 1 ASTM C14492, Type III (law -profile) .
1-1/TS'
T
I
Y
BE
Horizon Flat
u .� 1 ERD
T
BERMUDA FLAT, PLANTATION FEAT and HORIZON FLAT
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-2-RS
Certificate ojAuthorizotion #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision S: 10/17/2017
Page 3 of 6
i
I '
ED
I
4.2 ASTM D7 492Y Type (l: (medium -profile) 13ELLA IiIGH "S"� EsTAit "S"'and:HAciENbA .
- L
Bella High "S"
Estate "S"
4.3 ASTiyi C1492, Type.1(high-profile) GALENA SPANISH "S" and REGAL
Galena Spanish "S"
Exterior Research and Design, I.I.C.
Certificate oJAuthorization #9503
6" EDITION:(2017) FBC NON-HVHZ EVALUATION
i Entegra Roof Tiles
Regal
Evaluation Report E39310.11.11-2-R5
FL7804-R10
Revision 5: 10117/2017
Page 4 of 6
f TRINITY:; ERD
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer otRecord for any project on w'hicn this Evaluattion Report, or previous versions thereof, Is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire classification is not part of this evaluation; refer to FBC 1505.2, Exception 2 (for non-combustible deck)
or listing by an approved testing agency for fire rating of this product.
5.4 Underlayment shall hold Florida Local or Statewide Product Approval for use with tile roofing. systems. The
underlayment Product Approval shag' specr€y allor;sa:,-ge 'WstaNa V--, �i 7t'Cric?irf a�i
attachment, mortar -set and/or adhesive -set) for use with the specific underlayment. For mortar -set or
adhesive -set tile roofing applications ,1 the underlayment Product Approval shall specify attachment methods
for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April
2012 (04-12).
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6. (p(,STArl LET R,'
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of FBC
1507.3, the FRSAJTRI April 2012 (04-12) and, for mortar -set or adhesive -set applications, the mortar or
adhesive manufacturer's Product Approval.
6.2 Underlayment shall be installed in' accordance with FRSAJTRI April 2012 (04-12) or the underlayment
manufacturer's current Product Approval. For mortar -set or adhesive -set tale roofing applications, the
underlayment current Product Apprbval shall specify attachment methods for the underlayment system to
resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12).
6.3 Attachment:
6.3.1 Mechanically Attached Tile:
Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift
Moment determined in Table 2A or 26 of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3.
6.3.2 Mortar -Set Tile:
Wind load resistance shall be in accordance with Table 2A or 213 of FRSAJTRI April 2012 (04-12) or FBC
1609.5.3 in conjunction with the mortar manufacturer's Product Approval.
6.3.3 Adhesive -Set Tile:
Wind load resistance shall be in accordance with Table 2A or 213 of FRSA/TRI April 2012 (04-12) or FBC
1609.5.3 in conjunction with the adhesive manufacturer's current Product Approval. Refer to the current
version of the referenced Florida Product Approval for data,..
TILE ADHESIVES FOR ADHESIVE-SETTILE SYSTEMS
Manufacturer
Product s
Florida Product Approval
DAP Foam, Inc.
'Touch N' Seal Storm Bond"
FL14506
'Touch N' Seal Storm Bond 2"
FL21374
Dow Chemical
'TILE BOND""
FL22525
If-9 Adhe ken &,Sealants, inc-
IPc k,;sa: ' AH 1:60,,
F. Ln332.
E.,cteriorResearch and Design, LLC. 712 R5
Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 5: 10/1712017
Page 5 of 6
� f
TRI I ; ERD
6.3.4 Hip and Ridge Tile:
Tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge the installations
atop hip and ridge meta), refer to th!e hip and ridge meta) manufacturer's current Product Approva) (e.g.,
FL5374) or test report in accordance with SSTD 11 for allowable loads to resist those determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12).
7. LABELING:
7.1 Each unit shall bear the imprint and /ior identifiable marking of the manufacturer's name or logo. Tile lots
shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Autho lty Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant
Profiles
Okeechobee, F1
Bermuda Flat Plantation Flat Estate "S", B&j.1z. igh "S", Galena -Spanish "S'
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC.,—QUA9110; (813) 621-5777
- ENd OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-2-RS
Certificate oJAuthorization 09503 6" EDITION (2017) FSC NON-FiVHZ EVALUATION FL7804-RIG
Entegra Roof Ties Revision 5:10/17/2017
Page 6 of 6
Florida Building Code Online
Page 1 of 2
SCANNED
Lucie iCountt
sZvn'�§
BQS Home i Log In User Registration Hot Topics i Submit Surcharge ' Slats & Facts i Publications ? FBC Staff BCIS Site Map i Links i Search
Product Approval
01 -01E1: Public User
;. N
Product AWroval Menu > Product or,Apptication Search �> Application Lisp > Application Detail
FL #
4L6332-V1%
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer ICP Adhesives & Sealants, Inc.
Address/Phone/Email 12505 NW 44th Street
Coral Springs, FL 33065
! (888) 774-1419 Ext201
i ryiipelkonen@icpadhesives.com
Authorized Signature Riku Ylipelkonen
rylipelkonen@icpadhesives.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
Roof Tile Adhesives
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Robert Nieminen
the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
02/07/2021
Validated By
John W. Knezevich, PE
✓ Validation Checklist - Hardcopy Received
Certificate of Independence
FL6332 R8 COI 2017 01 COI Nieminen.pdf
Referenced Standard and Year (of Standard)
Standard Year
SSTD 11 1997
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
http://w-N,v-,v.floridabuilding.org/pr/pt_app_dt asp-%.? param=wGEVXQwtDquanCtKft6f°lo2f... 4/4/2018
Florida Building Code Online Page 2 of 2
Date Submitted 10/12/2017
Date Validated 10/14/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12,12017
Summary of Products
FL #
Model, Number or Name
Description
6332.1
ICP Adhesives Polyset AH-160
Dual component expanding polyurethane roof tile adhesive
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6332 R8 II 2017 10 FINAL ER ICP AH160 FL6332-
R8. dfdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +n/a/-178
Created by Independent Third Party: Yes
Other: 1.) The design pressure limitation in this application
refers to hip and ridge tiles in one configuration, Refer to
Evaluation Reports
FL6332 R8 AE 2017 10 FINAL ER ICP AH160 FL6332-
RB.pdf
Created by Independent Third Party: Yes
Table 2 of ER for all hip and ridge tile limitations. 2.) Field
tiles are designed based on overturning moment resistance.
Refer to Table 1 of ER for field tile limitations. 3.) Refer to
ER Sections 5 for other Limitations of Use.
Contact Us ::I 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850487-1824
The State of Florida is an AA/EEO employer. ,�vriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not %rant your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4S5, F.S. must provide the Department with an email address if
they have one. The email$ provided may be used foC official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which an be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
inn rr;)
Credit Care)
Safe
http://vww.flondabuilding.org/pr/pi_app_ il.aspx?param=wGEVXQwtDquanCtKft6t""%2f... 4/4/2018
TRIN1117v ERD
EVALUA T ICON REPORT
1CP Adhesives and Sealants, Inc.
12505 NW 44th Street
Coral Springs, FL 33065
(888) 774-1419
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT 13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report 02768.03.06-RE
FL6332-R8
Date of Issuance: 08/08/2008
Revision 8:10/12/2017
SCOPE: I
This Evaluation Deport is issued under Rule 61d120-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. ThiT documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6th Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: ICP Adhesives Polysetcl Ali-160
I
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COrv'IPUANCE. This Evaluation Report is iVand Jntrl Such tinge as the named productis% clTjng--5S. :-Q ref ra^�
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity(ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity ( ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be clone in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation- Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
T('_F-e,-simi e seaI Q==fiRU wds autho,!xe:d by Robcr t
Nieminen, P.C. on 10/12/2017. This does not serve as an
efectronicaflysiFneddocument.
CERTIFiCATiON OF INDEPENDENCE:
2 Exterit-)r RpseatCh & Design, 1. C. d1b(a Trinity, I FRO does riot have, nor doe; i, Intend to acquire or will it acquire, a financial interest
'rn 2rrry WrirpaYry•rncfn*UiaZtcn'rrrbvUt IMAt"?acrcrcA adrurdtc�.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company aanufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is ? building cirliP (wifluation. Neither Trinity) t Ri s?ar Z,;I?eft r.E. af'r3, iz: :ay rvvay, rho Desigaer -f Record or an},
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
Roomic. COMPONENT EVAI_UATIm,
1. SCOPE:
Product Category: Roofing
Sub -Category: Roof Tile Adhesives
Compliance Statement: ICP Adhesives PolysetO AM-160, as produced by ICP Adhesives and Sealants, Inc., has
demonstrated compliance vilth the 6trEdition; (2017) Florida Building Code through testing in accordance with the
Standards set forth herein. Compliance is slut jest to the installation Requirements and Limitations, Conditions of
Use set forth herein.
2. STANDARDS:
Sections
Proper
Standard
Year
1504.2.1.1
Overturning, es stance
5STD 11
1997
3. REFERENCES:
Entity
&arniriatfon
Reference
Date
ERD (TST6049)
Static Uplift-SSTD 11
P39740.02.12
02/20/2012
ERD (TST 6049)
Static Uplift—SSTD 11
P39740.11.13-131
01102/2015
ICC-ES (EVL2396)
2012 IBC Compliance
ESR-1709
12/01/2016
Miami -Dade (CER 1592)
HVHZ compliance
17-0322.03
04/27/2017
PRI (TST 5878)
Static Uplift—SSTD 11
ECM-001-02-01
09/21/2001
PRI (TST 5878)
Static Uplift — S_ISTD 11
PFI-006-02-01
05/09/2005
PRI (TST 5878)
Static Uplift—SSTD 11
PFP-006-02 n2
051109/2.005
PRI (TST5878)
Static Uplift—SSTD 11
PH-007-02-01
10/11/2005
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-008-02-04
02/21/2006
PRI (TST 5878)
Static Uplift—SSTD 11
PFI-009-02-03
02/21/2006
PRI (TST 5878)
Static Uplift—SSTD 11
TGRI-001-02-03
10/30/2006
PRI (TST 5878)
Static Uplift—SSTD 11
TGRI-001-02-03
10/30/2006
PRI (TST 5878)
Static Uplift—SSTD 11
PFPI-010-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SISTD 11
PFPI-011-02-01
12/07/2006
PRI (TST 5878)
Static Uplift — SSTD 11
PFPi-012-02-01
12/07/2006
PRI (TST 5878)
Static Uplift— 56TD 11
PFP(-018,02-01
12/07/2006
PRI (TST 58781
Static Uplift— SSTD 11
PFPI-014-02-01
12107/2006
PRI (TST 5878) 1Static
Uplift—SSTD 11
ECM-003-02-01
06/13/2008
PRI (TST 5878)
Static Uplift— SSTD 11
ECM-004-02-01
06/13/2008
PRI (TST 5878)
Static Uplift— SSTD 11
ECM-005-02-01
06/13/2008
PRI (TST 5878)
Static Uplift — SSTD 11
ECM-006-02-01
06,/1-4/2008
PRI (TST 5878)
Static Uplift — SSTD 11
ECM-007-02-01
06/13/2008
PRI (TST 5878)
Static Uplift—SSTD 11
ECM-008-02-01
06/13/2008
UL LLC (QUA 9625)
Quality Assurance
Service Confirmation
Exp. 0610512013
4. PRODUCT DESCRIPTION:
4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding. polyurethane roof tile adhesive that is mixed
and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are
available in refillable tanks or disposable cylinders (ICI' Adhesives ProPacl:'! 30 & 100).
S. e ififllT zoivs:
5.1 T,his ss a tisitding cede evaluation. Neithe Trinity(ERD nor Robert iNierninen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
Ex�edor Research and Design, LC. Evaivation'Report 132758.133 t S-R&
L2rhYrare ofAutharkarion #YS03 6' EDMON (2017) FSC NON-HVHZ EVALUAT10N FL6332-R8
ICP Adhesives'PoIVset1' AH-160: (989) 774-1419 Revision 8:10/12/2017
Page 2 of 9
TRINITY : E D
5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings
of this product and FBC 1505.2.
5.4 ICP Adhesives Polyset® AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof
assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority
Having Jurisdiction.
5.5 Minimum underlayment shall be peer FRSA/TRI April 2012 (04-12) or having a current Florida Statewide
Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives
Polyset® AH-160.
5.6 cietd fifes, tneef1trg the t[mikauoos tiT Eac Lisag s,:a, 4.LsinZ iCP Adhesives Pniyseto XK-1650 are limited to
projects having an Aerodynamic Uplift Moment (M.), determined in accordance with FBC 1609.5.3 or Tables
2A and 2B of FRSA/TRI April 2012 504-12), not greater than the following Allowable Overturning Moment
values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for
Adhesive Paddy Placement details.
TALE 1: F�ELD
TILES ir4 ICP ADHESIVES POLyScT� AH-160
ALLOWABLE
OVERTURNING MOMENT PERFORMANCE DATA
_ '. .2It71NrffRGMCOFSRFEIYHLREHOYFF.'PUL77
FDRlSODEPtl4YJElYf(Sl79GLEOtrCU10'RWr70USYitUfri"%YL'Rtt7VltNf
4-T0.'�MAR6/NOF5AFE7YALREADY,APPVED
FOR INTERDEPENDENT.(TWOPADDY) :�PLACEMENT ' -�
Tile (FBC 1609.5.3)
Adhesive Paddy Placement
Allowable
overturning
Type
Profile
I
Moment (ft-lbf)
Independent; Single Paddy, Medium (2x7-inch, -30 gram)
60
Clay
Fiat
Independent; Single Paddy, Large (2x10-inch, -45 gram)
112
Concrete
interdependent; ,wo Paddy (4x4-inch on underlayment, 2x4-inch attile overlap)
54
Independent; Single Paddy, Medium (2x7-inch, ^30 gram)
39
Clayor
Low/
Independent; Single Paddy, Large (2x10-inch, -54 gram)
67
Concrete
Medium
Interdependent;ITwo
Paddy (44-inch on underlayment 2x4-inch at tile overlap)
58
Clay
High
Independent; Si�gle
Paddy, Large (WO -inch, -45 gram)
134
Independent; Si{
gle Paddy, Medium (2x7-inch, -3D gram)
65
Clayor
High
Independent; Si
gle Paddy, Large (2x10-inch, -63 grain)
109
Concrete
Interdependent; tpvo
Paddy (4x4-inch on underlaymen4 2x4-inch at the overlap)
40
Clay
Barrel
2x10-inch x-35
gram for pans; 2 @ 1x10-inch x -17 gram for cap
147
Concrete
Barrel
2x10-inch x ^35 gram for pans; 2 @ 1x10-inch x-17 gram for cap
107
Clay
Cap atop 2x
independent: Cqntinuous
Paddy (^34 gram/ft)
135
stringer
I
Concrete
Capp 2x
a
independent: Continuous
Paddy (-34
116
at
strCta
gram/ft)
�r ,
Cap atop 2x
Interdependent:
1a5
stringer
Head: One (1) #10
x 2%" screw; Overlap: 1 x 6 inch (-10.5 gram)
Concrete
Cap atop 2x
Interdependent: .
I
76
stringer
Head: One (1) #10 x 2W' screw; Overlap: 1 x 6 inch (-10.5 gram)
5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRl April
2012 (0442). Alternate underlayment systems include those having a current Florida Statewide Product
Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP
Adhesives Poiyset4 A14-160.
5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with
ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard
TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in
SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning
moment'.
Exterior Research and Design, LLC. e'vaiva;fott Report 0276E.03.06-R8
Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-118
ICP Adhesives Polyseto AH-160; (888) 774-1419 Revision 8:1011212017
Page 3 of 9
TRINITY��
5.7 Hip and ridge tiles using ICP Adhesives PolysetO AN-160 are limited to projects having hip/ridge design pressure
requirements, determined in accordance with Table 1A of FRSA,TRI April 2012 (04-12), not greater than the
following values. Refer to ICP Adhesi i es and Sealants, Inc. published installation instructions for Adhesive
Paddy Placement details.
TABLE 2: Hip &iR@GETILES W ICP ADHESIVES" POLySE'rm 41i-160 "
ALLowAdLE UPLIFT RESISTANCE PERFORMANCE DATA
2 To 1 MARGIN OF SAFETY ALREADYAPPVED FOR INDEPENDENT-f CONTINUOUS PADDY) PLACEMENT .
4 TO 1 MARGIN OF SAF_F"e VAI READYAPPOED FOR INTERVEPS46ENr?LACE7V su—
Allowable
Tile
Substrate
Attachment Method
Design Pressure
(psf)
Clay
2x PT ridge board
Independent: Continuous Paddy (-34 gram/ft)
116
Concrete
2x PT ridge board
Independent: Continuous Paddy (- 34 gram/ft)
107
Clay
2x PT ridge board
Interdependent: Head: One (1) #10 x 2/:" screw;
90
Overlap: 1 x 6 inch 1-10.5 gram)
canuete
2xPT xidge baasd
Interdependent: !lead: One (1) €t10 x 2/" screw;
56
Overlap: 1 x 6 inch (-10.5 gram)
Clay or
Hip & Ridge Channel Metal (FL5374):
Independent: Continuous Paddy (^34 gram/ft)
169
Concrete
galvanized only
Clay or
Trim LockM (FL5374): alutninu4
Independent: Continuous Paddy {�34 gramJft)
173
Concrete
galvanized, GalvalumeO or stainless steel
Clay or
Trim Lock- Plus (FL5374): aiurriinu:n,
Independent: Continuous Paddy (� 34 bramJfi)
278
Concrete
galvanized, Galvalurne", orstainlless steel
i
Clay I
Top Notch (FL8095)
Independent: Continuous Paddy 32 gram/ft)
125
Concrete
Top Notch (FL8095)
Independent: Continuous Paddy 32 gram/ft)
146
6. INSTALLATION:
6.1 ICP Adhesives PolysetO AH-160 and the tile roof assembly shall be installed in accordance with FRSA%TRI
April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the
limitations outlined in Section 5.
6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12).
Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product
Approval.
6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP
Adhesives and Sealants, Inc. �
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
8. MANUFACTURING PLANTS:
Tomball, TX
9. QUALITy ASSURANCE ENTITY:
UL, LLC.-QUA9625; (847) 664-3623; LeAnna.Gracleckl@u1.corn
i
Exterior Research and Design, LLC. Evaluation Report 02768.03.06-RR
Certificate ofAuthorizodan #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-118
ICP Adhesives PolysetO AH-150; (888) 774-1419 Revision 9:10/12/2017
Page 4 of 9
i
TRIN@per®qy
ERD
10. PADDY PLACEMENT OF -TAILS (FROM St=P'AoKESws AND SEALANTS, INC. PUBLISHED LITERATURE)'
10.1 Independent, Medium Paddy:
Flax/Low ProfileTile.
Exterior Research and Design, LLC.
Certificate oJAathorization #9503
Nall through plastic cement
(when required)
Paddy (Beneath Tile)
Und?rlaymenx �_
r
t2in.
Battens optional I
��-- EaveClosure
Save Course �,: f` f —Fascia
High Profile Tile
i
6- EDITION (2017) FBC NON-HVHZ EVALUATION
ICP Adhesives Polyse , AH-160, 1989) 774-1419
I
I �
Medium ProfileTile
Evaluation Report 02768.03.06-RS
FL6332-R8
Revision 8:10f 12f 2017
Page 5 of 9
Independent, Large PaddV:
High ProfileTile
f
Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-RS
Certificate of Authorization 99503 6n1 EDITION (2017) F6C NON-HVHZ EVALUATION FL6332-RS
ICP Adhesives Poh/seV AH-160; (888) 774-1419 Revision 8:1011212017
Page 6 of 9
Lj
10.3 Interdependent, Two PaddV:
Flat/Low Profile Tile
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
it through plastic cetnent
hen required)
[tens
L al ion,
Z S
S(nqfv paddy
ontop ofthe
¢4x4in.
Caddy on
High Profile Tile
6' EDITION 2017) FBC NON-HVHZ EVALUATION
ICP Adhesives Polyset) AH-160; (898)774-1419
TRINITY, ERD
Paddy under the
Paddy (between tiles)
iJ Paddy (under tile)
0
Fascia
Medium ProfileTile
Evaluation Report 02768.03.05-118
FL6332-R8
Revision S; 10]1212017
Page 7 of 9
TRINITY, ER D
10.4 Two Piece Barrel (Cap & Pan) Tiler
11 Place enough adhesive to achieve 65 to 7(l
in contact with the pan tile.
2) Turn Covers upside down. Place adhaDh-c
112 in. to 1 Inch in from qulside edge of cover tile.
Install cover lllr..
Ensure 20 to 25 sq. in. contact area anI
cacti side of comr hle.l
Underlayment
�• , i �'P�
10.5
Steep pitch applications
(when required)
(motarshown)��
t":aephoie'`� �
Fascia Bloard
Remove top portion of the eave course cover tile.Abut to second course of
pan tiles. Ensure eaveiend of pan and cover tiles are Flush at eave line.
Twoj Piece Barrel -High Profile Tile
Abtad.=PPc4}":e17tAi{-ihdmaIt+v.11pSMwo-. da^1't!'ri 'fo::it:*aE�L:i:-:i:=v.'y at��"b!'e:9f:si:•c_St?11{.!!sir,_•s1
fit. i%!zi 0 .7 : d:', ; : xrtl Qr z.+�ti:.".8: . • ;ypb M Ary:.'i` ('E' iz w r.v!l :SCR i7.'i t' ;'i4uJ _,r _i.ai
11"o frame to provide ealhrltaac sm fr+me.
Exterior Research and Design, I.I.C. i Evaluation Report 02768.03.06-RB
Certificate of Authorization #9303 6m EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset° AH-160; 1888) 774-1419 Revision 8:1011212017
Page 8 of 9
10.6
Nip and Ridge (interdependent placements:
EVALUATION REPORT-
Exterior Research and Design, LLC. Evaluation Report 02768.03.06-RS
Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-RS
ICP Adhesives PolysetO AH-160; (888) 774-1419 Revision 8:10112/2017
Page 9 of 9
Florida Building Code Online
Page 1 of 3
SCI5 Homes I Log In I User Registration
Product Approval
USER: Public User
RMudAoor=al racy >
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
address/Phone/Email
Category
Subcategory
Compliance Method
SCANNED
BY _
St Lude COUnt/
{ SWxWt Surcharge I Stats & Fads { Publkatlans i Fac staff { aCIS Site Map I Links I Search
Sit > d4Wlcatlan Ust > Appltcatlan OOrall
FL9777-R11
Revision
2017
Approved
❑i
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscornIng.com
Greg Keeler
greg.keeler@owenscorning.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report- Hardoopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report I
Florida License
PE-74021
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
LZ(31/2020
Validated By
Locke Bowden P.E.
® Validation Checklist - Hardcopy Received
Certificate of Independence
FI 97T( all COI_OL'R14002 8a 2017 FBG Evaluation
Reeort
Weatherlack Non-HVHZ.odf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D 1970
2015
ASTM D 226
2009
ASTM G 155
2005
TAS 103
1995
UL 1897
20L2
Equivalence of Product Standards
Certified By
Sections from the Code
i
I
https://www.floridabuilding.org/pr/pr app_4tl.aspx?param=wGEVXQwtDgtgkcMGblcW7... 5/16/2018
Florida Building Code Online
Page 2 of 3
Product Approval Method
Method 1 Option D
Date Submitted
10/11/2017
Date Validated
10/11/2017
Date Pending FBC Approval
10/17/2017
Date Approved
1V12/2017
Summary of Products
PL #
Model, Number or Name
Description.
9777.1
Weatherlock G
Weatherproofing Underlayment
Limits of Use
installation Instructions
Approved for use In HVHZ: No
FL9777 R11 11 0CR140Q2.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.odF
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Others See evaluation report for limits of use.
Evaluation Reports
FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report
Watbe lode Non-HVHZ.odf
Created by Independent Third Party: Yes
9777.2
WeatherLocklG
(High Tear)
Weatherproofing Underlayment
Limits of Use
I
Installation Instructions
Approved for use in HVHZ: No
FL9777 1111 11 OCR14002.83 2017 FBC Evaluation Reoort
Weathercock Non-HVHZ.ndf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other. See evaluation report for limits of use.
Evaluation Reports
FL9777 RI AE OCR14002.88a 2017 FBC Evaluation Renort
Non-HVHZ.odf
Matherio
Created by Independent Third Party: Yes
9777.3
Weatherlock MAT
Waterproofing Underlayment
Limits of use
Installation Instructions
Approved for use in HVHZ: Yes
FL977Z RSl 1I OCR14002.8h 2017 FBC Evaluation Report
Weatherc%k HVHZ.odf
Approved for use outside HVHZ: No
Impact Resistant N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report For limits of use.
Evaluation Reports
EL9777 III AE OCR14002.8b 2017 FBC Evaluation Renort
Weathercock HVHZ.odf
Created by Independent Third Party: Yes
9777.4
WeatheriocklMAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
Fi4777 RII II OCRI4002.8a 2017 FBC Evaluation Sgggft
Weatherlaek Non-HVHZ.odf
Verified By: Zachary R. Priest 74022
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
other: See evaluation report far limits of use.
Created by Independent Third Party: Yes
Evaluation Reports
EL9777 1111 AE OCRi4002.8a 2017 FBC Evaluation Reap
Weathercock Non-HVHZ.pdf
Created by Independent Third Party: Yes
9777.5 WeatherLock Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use In HVHZs No FL9777 1111 11 OCR14002.8a 2017 FBC Evaluation gg=
Approved for use outside HVHZ: Yes Weatherlack Non-HVHZ.odf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
Created by Independent Third Party: Yes
9777.E Weatherl-ock Metal Weatherproofing Underlayment
Limits of use Installation Instructions
Approved for use in HVHZ: Yes FL9777 Rii lr OCR14002.8b 2017 FB val uallo_ n Report
Approved for use outside HVHZ: No Weatherlock HVHZ.odf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design pressures N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
111 .86 2017 FBC Evaluation
https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtgkcMGbieW7,,, 5/16/2018
Florida Building Code Online
Page 3 of 3
Weatherlack HVH_Z.odf
Created by Independent Third Party: Yes
?77 . Weath rL cae k,Specialty Tile & Metal Weatherproofing underlayment
:units of Use
Approved for use In HVHZs No
Ye
Approved for use outside HVHZ:s
Installation Instructions
FL9777 Ril 11 OCR14002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.odf
Impact Resistant.. N/A
Verified By: Zachary R, Priest 74021
Design Pressurea +0/-142.5
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL977] R11 AE 0CR14002.2p 2Q17 FBC Evaluation Report
WeatherlogN Non- V
Created by Independent Third Party: Yes
each
Contact WA :: 2601 Blair Stone Read. Tallahassee FL 3RS99 Phone; BSGAIZ-1821
The State of Flodda Is an AA/EED employer.! Convrloht 2pp7-2013 Aceesslblllty Statement :: Refund Statement
Under Florida law, ema9 addresses are public records. If you do not want your e-mail address released In response to a publk•recards request, do not Sand
elocbonk mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.139S. *Pursuant to
Section 455.275(1), Florida Statutes, effectiveOctober 1, 2012, Ikensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The amails provided may be used for official communization with the licensee. Howerer emall addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
Chapter 455, F.S., please dick hm ,
Product Approval Accoptsi
r6dit Gard
a
https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtgkcMGblcW7... 5/16/2018
CREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer:
Manufacturing Location:
Quality Assurance:
SCOPE
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE, a EDI11ON (2017)
OWENS CORNING ROOFING AND ASPHALT LLC
1 Owens Corning Parkway .
Toledo, OH 43657
(800) 438-7465
Brentwood, NH
Houston, TX
UL LLC
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1504.3.1, 1507.1.1
Properties:
Physical properties
REFERENCES
E tit �
issued October 11, 2017
PRI Construction Materials Technologies (TST5878)
NEI-03399.02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-042-02-01 REV2
ASTM D 1970
2016
PRI Construction Materials Technologies (TST5878)
NEI-045.02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-045.02-01
ASTM G 165
2005a
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-093.02-02
ASTM D 1970
2015
PRI Constructlon Materials Technologies (TST5878)
0CF-213-02-01
ASTM D 1623
2009
PRI Construdlon Materials Technologies (TST5878)
OCF-237-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2016
PRI Construction Materials Technologies (TST5878)
OCF-272-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-296-02-02
ICC-ES AC 188'
2012
ICC-ES AC 48
2012
PRI Construction Materials Technologies {TST5878)
OCF-297-02-01,1
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-318-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
OCF-321-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
CCF-322-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF,355-02-01
UL 1897
2012
'Determined to be equivalent to ASTM D 226.09, Type I
and 11
OCR14002.8a
This evaluation report is provided for State of Florida product approval under Rule 61G20.3. The manufbcturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughput the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
WeatherLock® G WeatherLock® G Is an ASTM D 1970 self-adhesive underlayment constructed from SBS
(Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied lin 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLockO G Is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock® Mat
Weetherl-oclk® Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH or
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, TX)
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft. 1
WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days
WeatherLock® Metal
WeatherLock® Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock® Metal Is permitted to be used as prescribed In FBC Section 1607.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days'.
I
WeatherLock@
WeatherLock® Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tfle & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied In 2.14 sq, rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, TX)
WeatherLock® Specialty Tile & Metal Is permitted to be used as prescribed in FBC
Section 1507.1.1.1 WeatherLockQD Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICI?
Adhesives and Sealants, Inc.) or TILE BONCm Roof 'Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock® G (High
WeatherLock® GI(High Tear) Is a self -adhered, underlayment used as an alternative to
Tear)
ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer
(Houston, 7X)
modified bitumen;underlayment. The underlayment Is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and Is surfaced with granules. The
product is supplied with a nominal thickness of 50 mlls in 1.95-sq rolls with nominal
dimensions of 3-ft x 65-ft.
Weatherl-ockO G (High Tear) is permitted to be used as prescribed In FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
OCR14002.8a FL9777-R11 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shelf notify CREEK
Technical Senrices, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
Weatherl-ockD Setf-Seating Ice & Water Barriers
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
Min. Roof Slope: 2:12 In accordance with the FBC
Application: All underlayments I hall be installed in accordance with me FBC.
Deck substrates shall be clean, dry, and free from any tnegulariftes and debris. A#
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning Installation, the undedayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlaymentlshall be installed with the release backer removed and pressed thinly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the save, starting at the eave, and with minimum 3" side
laps and minimurrj 6" end laps staggered min. 64from preceding course. Additionally, If
applying WeatherLock@ Specialty Tile &,Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 Inches across the width
of the lap.
It is permissible to back nail the undedayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, WeatherLock@ Specialty Tile & Metal shall be back nailed
when installed on Iroof slopes greater than 3:12.
Min. Application 40°F; Contact thel manufacturer when instaft at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlayment System No.1 — Weatherl-ock SpecialtyTile & Metal Only
Roof Deck: Min. 15/32-Inch CDX plywood attached to wood supports spaced a maximum 24" o.m
Undedayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnalled along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-Inch 0 tin caps spaced 12" o.c. The applied
undedayment shall be rolled with a minimum 751b steel roller Immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a
FL9777-Rll
3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20,3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor Imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TRCHNICAL SERVICES, LLC
GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock(D Self -Seating Ice & Water Barriers
1) This evaluation report is not use in the'HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions.' Where discrepancies exist between these sources, the more restrictive and FBC
compliant Installation detail shall prevail.
4) The roof deck shalt be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall tie properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed toy shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding In accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a ;given underlayment shall most or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code dh Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
`,, srstrtrrr����,
No 74021
r �
STATE OF
i0i�•.•A
i ......•' Cam`
�,'SS,ONA, ti��0,•
CERTIFICATION OF INDEPENDENCE
09:06:29
04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9841
CREEK Technical Services, LLC does not have, nor will it acquire, a 11nanclal Interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14002.8a FL9777-R11 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Flonda.Building Code Online
Page 1 of 2
� �,. T.� '��� i' �
��. SCANNED i r r.
�tt
BQS Home i Log In i User Registration 4 Hot Topics I Sub 1 h ei Publications ;�FBC State i BCIS Site Map Unks Search
"4r t fi� Product Approval
13! USER: Public User
2.
it Product Aooroval Menu > eroduct oDlication Search > implication L st > Application Detail
FL # FL5374 RS
` Application Type Affirmation
Code Version 2017
Application Status Approved
Comments
Archived 0
Product Manufacturer
East Coast Metals, Inc.
Address/Phone/Email
2301 West 8 Lane
Hialeah, FL 33010
(305) 885-9991
I
acastellanos@eastcoast-metals.com
Authorized Signature
Tom Castellanos
i
acastellanos@eastcoast-metals.com
I
technical Representative
Tom Castellanos
Address/Phone/Email
2301 West 8 Lane
Hialeah, FL 33010
(305)885-9991
tcastellanos@eastcoast-metals.com
Quality Assurance Representative Howard Callender Jr.
Address/Phone/Email 2301 West 8 Lane
Hialeah, FL 33010
(305)885-9991
hca (lender@eastcoast-metals.com
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing
System
Compliance Method Evaluation Report from a Florida Registered Architect or a
Licensed Florida Professional Engineer
- Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who; developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Robert Nieminen
PE-59166
Architectural Testing, Inc., an Intertek company
12/31/2018
John W. Knezevich, PE
13 Validation Checklist - Hardcopy Received
FL5374 R5 COI 2015 O1 COI Nieminen Ddf
Standard
Year
FRSA/TRI April 2012 (04-12)
2012
RAS 118
1995
RAS 119
1995
RAS 120
1995
SBCCI SSTD 11
1997
TAS 101
1995
http://www.floridabuilding.org/prlpi_app_dtl.aspx?param=wGEVXQwtDgtVSv8n7ODFXf... 5/ 17/2018
Monda Building Code Online
! J
Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
''MiI affirm that there are no changes in the new Florida
Building Code which affect my product(s) and my product(s)
are in compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity "'Yes -::.,No ` IN/A
FL5374 R5 COC 2017 09 AFFIRMATION ECM FL5374 6th
Edition (2017).pdf
I
Product Approval Method
Method 1 Option D
Date Submitted
09/06/2017
Date Validated
09/06/2017
Date Pending FBC Approval
Date Approved
I
09/10/2017
Summary of Products
FL #
Model, Number or Name
Description
5374.1
East Coast Metals Channel Metals
Preformed metal channels designed for use as a hip & ridge
base to which roof tiles are bonded.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5374 RS II 2015 03 FINAL ER ECM Trim
Approved for use outside HVHZ: Yes
Lock FL5374-R4. ddf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-178
Created by Independent Third Party: Yes
Other: 1.) Refer to Evaluation Report Sections 5.2 and 5.3
Evaluation Reports
for Limits of Use in HVHZ and non-HVHZ jurisdictions,
FL5374 R5 AE 2015 03 FINAL ER ECM Trim
respectively. 2.) The design pressure herein pertains to use
Lock_ FL5374-R4.Ddf
In non-HVHZ jurisdictions in conjunction with Table 3A of
Created by Independent Third Party: Yes
FRSA/TRI April 2012 (04-12). Refer to Tables 2A and 2B In
the Evaluation Report for all options and associated
allowable design pressures.
back rdext
Contact Us :: 2601 Blair Stone Road. Tallahassee 32399 Phone: 850-487-1824 '
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
Chapter 455, FS., please click here ,
Product Approval Accepts:
Credit Card
.Safe
http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGE VXQwtDgtVSv8n7ODFXf... 5/17/2018
ti RINITY I ERD
EVALUATION REPORT
East Coast Metals, Inc.
2301 West 8 Lane
Hialeah, FL 33010
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate ofAuthorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report E10240.08.08-R4
FL5374-R4
Date of Issuance: 09/03/2008
Revision 4: 03/17/2015
SCOPE:
I
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 15th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
I
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
�; ;';� .+� r The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M. Nieminen, P.E. fi c
Florida Re istration No. 59166, Florida DCA ANE1983 �yFu^^'� �, ., P.E. on 03f17/2015. This does not serve as an electronically signed
9 1,,.�. L
t 0 document. Signed, seated hardcopies have been transmitted to the
dig:ruwna�
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity] ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
1 TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subjectto the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property i
Standard
Year
1507.3.7
Installation, non-HVHZ
FRSA/TRI April 2012 (04-12)
2012
1518.8.1
Installation, HVHZ
RAS 118,119 & 120
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1711.2.1
Static Uplift Resistance
SBCCI SSTD 11
1997
3. REFERENCES:
i
Entity
Examination
Reference
Date
ERD (TST6049)
Static Uplift Resistance
E42730.08.13
08/23/2013
ERD (TST6049)
Static Uplift Resistance
ECM-SC6795.12.14-1
02/27/2015
ERD (TST6049)
Static Uplift Resistance
ECM-SC6795.12.14-2
02/27/2015
Florida TEC (TST7393)
TAS 101
S10-628R
10/27/2010
PRI (TST5878)
TAS 101
ECM-001-02-01
09/21/2001
PRI (TST5878)
TAS 101
ECM-003-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-004-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-005-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-006-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-007-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-008-02-01
06/13/2008
Florida Building Code
Attachment Requirements
FRSA/TRI April 2012 (04-12)
04/2012
Florida Building Code - HVHZ
Attachment Requirements
RAS 118, 119 and 120
1995
East Coast Metals
Metal Quality
Mill Certifications
Various
Architectural Testing (QUA1844)
Quality Control
Participation Letter
Exp. 12/31/2018
4. PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive.
Hip & Ridge Channel Metal is available in 119-3/8-inch (±
3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch (± 3/8-inch)
heights with 1.5-inch (± 1/16-inch) deck -flanges.
Exterior Research and Design, LLC.
Certificate of Authorization 09503
Evaluation Report E10240.08.08-R4
FL5374-R4
Revision 4: 03/17/2015
Page 2 of 7
\"]'T'�'_�INITYIERD
4.2 Trim Lock Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive.
i
Trim Lock Channel Metal is available in 119-3/8-inch (±
3/8") length by 3, 3.5, 4, 5 or 6-inch (±i 3/8-inch) heights
with 1.5-inch (±1/16-inch) deck -flanges.,
4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof the adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC
Approved roof tile adhesive, which flows -through and
interlocks with the underlying adhesive
Trim Lock Plus Channel Metal is available in 119-3/8-inch
(±3/8") length by 3, 3.5, 4, 5 or 6-inch (±3/8-inch) heights
with 1.5-inch (± 1/16-inch) deck -flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
➢ Galvanized Steel: Min. 0.019 ±0.002-inch, ASTM A653 (G-90), min. 33 KSI.
➢ Galvalume Steel: Min. 0.019 ±0.002-inch, ASTM A792, AZ55, min. 35 KSI.
➢ Aluminum: Min. 0.032 ±0.002-inch, ASTM B209; 3003-H14, min. 21 KSI.
➢ Stainless Steel: Min. 0.019 ±0.002-inch, ASTM A240/A480, T304, min. 35 KSI.
5. LiMiTATioNs:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design, LLC. Evaluation Report E10240.08.08-R4
Certificate oJAuthorization #003 FL5374-114
Revision 4: 03/17/2015
Page 3 of 7
� TRINITY I ER®
I
5.2 FOR HVHZJURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein. 1
5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
120, and the data in Tables 1A and 1B is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance (Mr) or uplift resistance (Fr),
as determined in accordance with RAS 127, not greater than the following values.
Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement' means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are :not bonded. This method is limited to 2-part tile adhesives. Allowable
performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
"INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE.Z14 PERFORNIANCEUMITATiDNS'HVHZ,INDEPENDENTPADDYP.LACEMENT
-„(2To,1MARGINOFSAF#YALRFADYAPPCIEDl
Hip/Ridge Metal
rile
Adhesive
Allowable Performance
Design
g
Metal Type
yp
Type
Placement
Moment Based
Uplift Based
MI(ft-lbf)
F' (Ibf)
Hip & Ridge
galvanized
g
clay or
3M' 2-Component Foam
Independent
127
169
Channel Metal
concrete
Roof Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume",
clay or
3M' 2-Component Foam
independent
171
159
aluminum or stainless steel
concrete '
Roof Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume°,
clay or
3M— 2-Component Foam
Independent
177
165
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
TABLE 1B PERFORMANCE LI
"RATIONS HUHZ, INTERDEPENDENT PAbbY;PLACEMENT
t ; �Q TOZMARQIAlOF¢AFEIY-AtREA1)YAPPtlED�_,`
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
Type
Placement
Moment Based
Uplift Based
Mf (ft Ibf)
F' (lbf)
Trim Lock or Trim
galvanized, Galvalumem,
clay or
3M— 2-Component Foam
Lock Plus
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Interdependent
95
88
Trim Lock
galvanized, Galvalume°,
clay or
3M— Roof Tile Adhesive
Interdependent
99
94
stainless steel
concrete
RTA-1
Trim Lock
aluminum
clay or
3MTM Foam Roof Tile
Interdependent
90
84
concrete
Adhesive RTA-1
Trim Lock Plus
galvanized, Galvalume®,
clay or
3M— Foam Roof Tile
Interdependent
90
84
aluminum or stainless steel
concrete
Adhesive RTA-1
Trim Lock
galvanized, Galvalume° or
clay or
TILE BOND"' Roof Tile
stainless steel
concrete
Adhesive
Interdependent
123
117
Trim Lock
aluminum
clay or
TILE BOND" Roof Tile
Interdependent
79
73
concrete
Adhesive
Trim Lock Plus
galvanized, Galvalume°,
clay or
TILE BOND" Roof Tile
Interdependent
79
73
aluminum or stainless steel
concrete
Adhesive
Trim Lock
galvanized, Galvalume° or
clay or
Touch'n Seal Storm Bond
stainless steel
concrete
Roof Tile Adhesive
Interdependent
146
139
Trim Lock
Aluminum
clay or
Touch'n Seal Storm Bond
Interdependent
58
54
concrete
Roof Tile Adhesive
Trim Lock Plus
galvanized, Galvalumem,
clay or
Touch'n Seal StormBond
Interdependent
58
54
aluminum or stainless steel
concrete
Roof Tile Adhesive
Exterior Research and Design, I.I.C. Evaluation Report E30240.08.08-R4
Certificate of Authorization #9303 FL5374•R4
Revision 4: 03/17/2015
Page 4 of 7
TRIM' j ERD
5.3 FOR NON-HVHZJURISDICTIONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal, refer to the installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-parttile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE2A .PERFORMANCELIMRA7IONS NON�IVHZrINDEPENDENTPADDYPtACEMENT i
;•
. •- ' - _ - MAg6jA10 SAFE7YALREgDYAPP_L!_EDf
Hip/Ridge Metal
Tile
Adhesive
Adhesive
Uplift
(pso
Design
n
Meta1T a
Type
Type
Placement
Hip & Ridge
g alvanized
clay or
3MT" 2-Component Foam Roof
Independent
169
Channel Metal
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume°, aluminum or
clay or
3MT" 2-Component Foam Roof
Independent
173
stainless steel
concrete
Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume®, aluminum or
clay or
310P" 2-Component Foam Roof
Independent
178
stainless steel
cohcrete
Tile Adhesive AH-160
"' TABLE26 PERFORMANCELimrrA ONS NON H!/HZ INTERDEPENDENT PADDYPLACEiV1ENT, -
oTOIMA$GINOFSAFE7YALREADYAPPLIED�:;" t
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(Ps f)
n Desi
g
MetalT a
Yp
Type
Placement
Trim Lock or Trim
galvanized, Galvalume°, aluminum or
clay or
3MT" 2-Component Foam Roof
Lock Plus
stainless steel
concrete
Tile Adhesive AH-160
Interdependent
98
Trim Lock
galvanized, Galvalume° or stainless
clay or
3MT" Foam RoofTile Adhesive
steel
concrete
RTA-1
Interdependent
110
Trim Lock
aluminum
clay or
3MT" Foam Roof Tile Adhesive
Interdependent
93
concrete
RTA-1
Trim Lock Plus
galvanized, Galvalume°, aluminum or
clay or
3MT" Foam RoofTile Adhesive
stainless steel
concrete
RTA-1
Interdependent
93
Trim Lock
galvanized, Galvalume° or stainless
clay or
TILE BOND— RoofTile Adhesive
Interdependent
152
steel
concrete
Trim Lock
aluminum
or
TILE BOND" RoofTile Adhesive
Interdependent
82
concrete
te
Trim Lock Plus
galvanized, Galvalume°, aluminum or
clay or
TILE BOND" RoofTile Adhesive
Interdependent
82
stainless steel
concrete
Trim Lock
galvanized, Galvalume° or stainless
clay or
Touch'n Seal Storm Bond Roof
steel
concrete
Tile Adhesive
Interdependent
148
Trim Lock
Aluminum
clay or
Touch'n Seal Storm Bond Roof
Interdependent
61
concrete
Tile Adhesive
Trim Lock Plus
galvanized, Galvalume°, aluminum or
clay or
Touch'n Seal StormBond Roof
stainless steel
concrete
Tile Adhesive
Interdependent
61
Exterior Research and Design, I.I.C. Evaluation Report E10240.08.08-R4
Certificate oJAuthoriration 49503 FL5374-R4
Revision 4: 03/17/2015
Page 5 of 7
TRINITY ER®
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1%-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be
positioned %-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to
FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1:5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
View of Polyset AH260 Placement for Trim Lock Plus Channel Metal Installation
6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not
disturbed prior to or during placement ofthe ridge tiles.
6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved
use of the subject tile adhesive.
Exterior Research and Design, LLC. Evaluation Report E10240.08.08-R4
Certificate ofAuthorkation #9503 FL5374-R4
Revision 4: 03/17/2015
Page 6 of 7
TRINITY I ER D
6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved, published
installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118, RAS 119, RAS 120 requirements.
Hip / Ridge Tile
Tile Adhesive
Trim Lock Plus
Mortar or Weather Block
Adhesive
Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
S. MANUFACTURING PLANTS:
Contactthe named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc. — QUA1844; (717) 764-7700
- END, OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4
Certificate of Authorization #9503 FL5374-R4
Revision 4: 03/17/2015
Page 7 of 7