HomeMy WebLinkAboutBUILDING PLANSI o MARTIN COUNTY, FL 11'-8" X 24'=O" SHELTER M� t«'>1 EME NO SMOI�MG o a o 0 0 0 0 0 Building Notes: - These plans comply w/ Rule 6TG20-3.006 for product approval The sealed set of plans are on file in the third party agency's office as directed by the DBPR This building has NOT been designed or approved for placement in High Velocity Hurricane Zones (HVHZ) This building is subject to review and approval of the fire inspector on site w/ compliance w/ Ch, 633 Fire Safety Code The manufacturer's data sheet and the state (DBPR) nsigria shall be permanently mounted to or about the electrical panel This structure has been designed for erection or installation on a site built permanent foundation and is not designed to be moved once erected or installed Light Frame Construction Identification Placards (on site or details provided) SPECIAL CONDITIONS / LIMITATIONS I. SEPARATION FROM EXISTING STRUCTURES TO BE 10' OR GREATER. 2. THI5 STRUCTURE 15 NOT DESIGNED FOR INSTALLATION IN A FLOOD HAZARD AREA. 3. THIS STRUCTURE 15 NOT DESIGNED FOR HUMAN OCCUPANCY EXCEPT FOR SHORT TIME PERIODS FOR EQUIPMENT MAINTENANCE. 4. THERMOBOND WILL NOT BE RESPONSIBLE FOR INSTALLATION OF ANY SPRINKLER SYSTEM, WHICH MAY BE REQUIRED BY LOCAL BUILDING OFFICIAL. S. THERMOBOND WILL NOT BE RESPONSIBLE FOR ANY ANTENNA INSTALLATION ASSOCIATED WITH THIS BUILDING. 6. THIS BUILDING SHALL NOT BE LOCATED AT A SITE THAT EXCEEDS THE LISTED DESIGN LOADS. 7. IF BATTERIES W/ AN ELECTROLYTE CAPACITY OF MORE THAN 50 GAL. ARE TO BE INSTALLED IN THIS BUILDING, ONE OF THE FOLLOWING MUST BE INSTALLED BY OTHERS ON SITE: a. AN EXHAUST FAN W/ A HYDROGEN LIMIT SWITCH TO LIMIT THE HYDROGEN TO 1% OF THE TOTAL VOLUME OF THE ROOM. b. CONTINUOUS VENTILATION SHALL BE PROVIDED AT A RATE NOT LE55 THAN I CU.FT. PER MINUTE PER 50.FT. OF FLOOR AREA OF THE ROOM. 8. THI5 BUILDING IS NOT INTENDED FOR OCCUPANCY. THE LIGHTING SHOWN IS REQUIRED FOR A SERVICE TECHNICIAN TO FUNCTION SAFELY. DESIGN LOADS OCCUPANCY TYPE (RISK CAT.): IV FLOOR LIVE LOAD: 300 psF ROOF DESIGN LOAD (STRENGTH): 150 psf ROOF DESIGN LOAD (DEFLECTION): 75 psf Pf - (0.7) * (Ce) * (1) * (Ct) * (Pg) WIND DESIGN WIND SPEED: 168 Vult (ASCE 7-10) EXPOSURE: D Iw=1.15 a=3Ft GCpi = t 0.18 (PER ASCE 7) ENCLOSED BUILDING INTERNAL PRESSURE EXPOSURE FACTOR Ce = 1.0 ZONE 1: P= + 24.20 PSF P= - 5q.50 PSF IMPORTANCE FACTOR Is = 1.15 ZONE 2 P= + 24.20 PSF P= - 9q.90 PSF THERMAL FACTOR Ct = 1.0 ZONE 3: P= + 24.20 PSF P= - 150.30 PSF GROUND SNOW LOAD Pg = 60 ZONE 4: P= + 54.50 PSF P= - 5q.50 P5F ZONE 5: P= + 54.50 PSF P= - 6q.60 P5F ITEMS TO BE INSTALLED ON SITE AND ARE SUBJECT LOCAL INSPECTION ; 1, Installation of foundation Tie Down Plates, 2, Installation of door canopy. 3. Installation of 70kw generator, SHIPPING INFORMATION: SEISMIC DESIGN: COPY BUILDING DEAD LOAD: 72,000 LBS SHIPPING HEIGHT: 10'-5 1/8" BUILDING FOOT PRINT: 280 50. FT. SHIPPING WIDTH: 11'-8" SEISMIC DESIGN CATEGORY: D SHIPPING LENGTH: 24-0" BA51C SEISMIC -FORCE -RESISTING SYSTEM: INTERMEDIATE PRE -CAST WALL SHIPPING WEIGHT: 72,000 LBS ANALYSIS PROCEDURE: ELF ASSUMED SITE CLASS: D DESIGN SPECTRAL RESPONSE ACCELERATION: 55 ■ 1.50 51 = 0.10 SITE COEFFICIENTS: FA = 1.00 FV = 2.2 DESIGN BASE SHEAR: V = CSW = (0.375) (72,000% = 27000 LBS W - ESTIMATED WEIGHT WITH EQUIPMENT le - 15 SCA1>nNE-4 13Y St Lucie County sgezk)2 St LUCIE PLAN R DATE: DATE: PLUMB: _ DATE: MECH: DATE DRAWING INDEX SHEET DESCRIPTION REV 12 REV =VREV REV 5 REV 6 Cl COVER SHEET C2 MATERIALS L15T Al FLOOR PLAN A2 ELEVATIONS A3 FOUNDATION El ELECTRICAL SCHEMATIC ELI ELECTRICAL PANELS E1.2 ALARM DIAGRAM E2 GROUNDING LAYOUT E2.1 GROUNDING DETAILS E3 WIRE MOLD E4 ELECTRICAL DIMENSIONS E5 ELECTRICAL DETAILS 51 FLOOR CASTINGS 52 WALL CASTINGS 52.1 WALL CASTINGS DETAILS 53 ROOF CASTINGS 54 GRO55 SECTION T1 TRANSPORT CONNECTIONS T2 INSTALL DETAILS RELEASE DATES STATUS RELEASED TO BY DATE P=PROGRESS F=FINAL R=REVISED PR=PRODUCTION C=CUSTOMER 5=STATE/THIRD PARTY REVISIONS REV DESCRIPTION BY DATE I _ 2 3 4 5 6 7 FLORIDA OCCUPANT LOAD: I CONSTRUCTION TYPE: 56 USE GROUP: 52 CODES: 2011 NATIONAL ELECTRIC CODE 2014 FLORIDA STATE BUILDING CODE -BUILDING 2014 FLORIDA STATE BUILDING CODE -MECHANICAL 2014 FLORIDA STATE BUILDING CODE -ENERGY (EXEMPT FROM FLORIDA ENERGY CODE PER. SEC. 101.4.8.5 FOR EQUIPMENT SHELTERS) �I FT ° 439 - Model AGE3959G " e sues i . dp FL OW ...9.+m. STAMPS AND SEALS Ja��WttM^z za wZ p pi j�0O N ut~��ZZappu� of W in ^ �' V/ W 2_ J LL s �o O p N C) . O 2 60 r (40 J LL Ln Alma 9+ O V im LLI QL z � z w �z ry a a DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Na ner SERIAL NUMBER: 1603-105 SCALE 24X36: NONE SHEET: C 1 IL MATERIALS LIST ITEM QTY UM DESCRIPTION MANUFACTURER MFR PART NUMBER TBB PART NUMBER NOTE i EA 300A PANELBOARD INTERIOR SQUARE D N0421-2C 200-0276 8,12 1 1 EA 300A PANELBOARD MCB KIT SQUARE D NQM54LA 200-0467 8 1 EA MAIN CKT BKR, 2/300A SQUARE D LAL26300 200-0598 8 1 EA 300A PANELBOARD BOX SQUARE D MH62 200-0464 B 2 1 EA 300A PANELBOARD COVER SQUARE D NC62S 200-0465 8 3 2 EA IGROUND BAR SQUARE D PK15GTA 700-0022 6 4 1 EA CKT BKR, 2/15A SQUARE D 00216 200-0023 8 5 2 EA CKT BKR, 1/15A SQUARE D Q0115 200-0051 8 6 2 EA CKT BKR, I/BOA SQUARE D 00130 200-0054 8 7 2 EA CKT BKR, 2/50A SQUARE D =50 200-0065 8 8 I EA CKT BKR, 2/60A SQUARE D 00260 200-0066 8 q 2 EA CKT BKR, 2/125A SQUARE D Q02125 200-0070 8 10 106 EA JCKT BKR, 1/20A SQUARE D 00120 200-0052 8 11 2 EA 200A SUB -PANEL, 1�/3W SQUARE D 0014ON200 200-0152 8 12 2 EA SUB -PANEL COVER SQUARE D QOC40US 200-0164 8 13 4 EA GROUND BAR SQUARE D PKI8GTA 700-0022 6 14 4 EA GROUND BAR ISOLATOR KIT SQUARE D PKGTAB 200-01g7 8 15 1 EA CKT BKR ENCLOSURE, 400A WITH NEUTRAL KIT SQUARE D LA40OS/4005N 200-0601 200-0346 8,12 I6 I EA CKT BKR, 2/300A SQUARE D 04L2300 200-0602 8 17 1 EA CKT BKR ENCLOSURE, 100A SQUARE D 00210OBNS 200-01% 8112 IS 1 EA JCKT BKR, 2/60A SQUARE D 00260 200-0066 6 Ig 1 EA SURGE ARRESTOR, TYPE 2 - MOV, 120/2401 1�/3W TRAN5TECTOR DSAPEXIMAX608MM 100-0065 8,12 20 1 EA SURGE ARRESTOR, TYPE 1 - SAD/MOV, 120/240, Io/3W TRANSTECTOR DSAPEXIMAX808 100-0087 8112 21 4 EA SURGE PROTECTION, 120V MODULE TRANSTECTOR 12R-ICP120V 100-0181 8 22 5 EA SURGE PROTECTION, 13V MODULE TRANSTECTOR D5WPHO3 101-0526 B,12 23 1 EA ENCLOSURE, 3R, 6 X 6 X 4 HOFFMAN A6R64NK 300-0172 7 24 3 EA ENCLOSURE, NI, 6 X 6 X 4 HOFFMAN ASEGX6XANK BOO-0173 7 25 2 EA ENCLOSURE, NI, 12 X 12 X 6 HOFFMAN ASE12X12XGNK 300-0174 7 26 2 EA INEAT14ERPROOF GFCI RECEPTACLE PASS 4 SEYMOUR 2095TRWRl 800-0034 8 27 8 EA IDUPLEX RECEPTACLE LEVITON CR20-1 800-0031 7112 28 3 EA SINGLE POLE SWITCH LEVITON C5120-21 BOO-0058 7 2q 8 EA 48" 32H 2-BULB FLUORESCENT LITHONIA 58 2 32 120 RE BDP 500-Olg2 7 30 31 1 EA EMERGENCY/EXIT LIGHT LITHONIA LHQM 5 W 3 R 600-0019 7 32 I EA LED EXTERIOR LIGHT W/PHOTOCELL LITHONIA OLW14 500-0040 2,7 33 2 EA 48,000 BTU HVAG W/5KW HEAT MARVAIR AVPA46ACA05ON Sqq-035q 8 34 2 EA SUPPLY GRILL MARVAIR 80676 S99-0026 8 35 2 EA RETURN GRILL MARVAIR 80679 899-002q 8 36 1 EA LEADLAG MARVAIR COMMSTAT 3 100-0030 8,12 37 38 1 EA ENTRY PORT, 4 X 3 MICROFLECT B1334 Iqq-0085 8 3q 1 EA GROUND BAR KIT HARDER EPK12MOT 200-0116 8 40 3 EA 66 BLOCK W/AMPNENOL CONNECTOR SIEMON 566M12-5W 050-0022 7112 41 3 EA AMPHENOL CABLE ORTRONICS OR-804025PCO50-IGY 752-0080 7 42 150 EA BRIDGE CLIP SIEMON SAl-55-100 050-0004 7 43 1 EA DOOR ALARM SENTROL 1047T 500-0106 7,12 44 1 EA 3070 DOOR, RP OUTSWING (FL4553) CECODOOR 0q8-1120 d 0%-0120 4 45 1 EA IDEADBOLT COMPASS Oq8-2230 7 46 1 EA ICORE, 7-PIN, A -TYPE CENTRAL IN HARDWARE 003-1012 7 47 1 EA PA55AGE LEVER SET COMPASS 0%-2110 7 48 I EA NRP-SS HINGES, SET OF 3 SOMMER B55000-N-652 OqB-3110 7 4q I EA MAGNETIC WEATHER STRIPPING (3070) PEMKO 2815 OqB-3210 7 50 1 EA 36" THRESHOLD REESE 5205 Oq8-3310 7 51 1 EA 36" NEOPRENE STYLE DOOR SWEEP REESE 323C OqB-3410 7 52 1 EA ANTI -PICK PLATE LATCH GUARD LGIOOZ/SF Oq8-3650 7 53 1 EA 36" THRESHOLD STOP REESE 095-3311 7 54 1 EA 40" DRIP CAP COMPASS Oq8-3610 7 55 I EA HYDRAULIC DOOR CLOSER WITH HOLD OPEN ADVANTAGE 8001 Oq8-3522 7 56 1 EA 13070 DOOR CANOPY B*T OqB-3660 2,4 57 1 EA IOLB CO2 FIRE EXTINGUISHER KIDDE PROIOCDM 3qq-0051 2,7 56 1 EA 120LB DRY CHEM FIRE EXTINGUISHER KIDDE PP020TCM Sq9-0067 2,7 5q I EA METAL WALL POCKET SAFCO 21DIgq 001-2048 7 60 1 EA EYE WASH HONEYWELL GRAINGER# 3ARD6 3q9-0255 7 61 1 EA FIRST AID KIT NORTH GRAINGER# 4EYg2 3qq-0254 7 62 1 EA NO SMOKING SIGN BRADY GRAINGER# 4T676 3qq-0108 7 63 1 EA ELECTRO EMISSION SIGN RICHARD TELL ASSOCIATES TE55CQ# 2037q 3qq-0109 7 64 1 EA TELCO BOARD, 3' X 4' X 3/4", GRAY THFRM050ND 753-2191 65 1 EA POWER FAIL RELAY W/BASE DAYTON GRAINGER# 3X740/5X852 100-0034 fi 100-0001 7,12 66 50 FT 24" CABLE LADDER W/HARDWARE CENTRAL STEEL FABRICATORS 10024 001-2231 7113 67 10 FT 6" CABLE LADDER W/HARDWARE CENTRAL STEEL FABRICATORS 10006 001-2232 7113 68 1 EA JAASTE BASKET TOUGH GUY GRAINGER# 4PGN2 3qq-Olgq 117 6q I EA IDUST PAN TOUGH GUY GRAINGER# IVAJ7 3qq-0054 117 70 1 EA BROOM TOUGH GUY GRAINGER# IVAC2 101-0301 1,7 71 1 EA UTILITY HOLDER BATTALION GRAINGER# 4466 101-0528 7 72 1 EA 4" WIREWAY, IOFT B-LINE 44120 G NK 300-0037 7 73 2 EA 4" WIREWAY, 4FT B-LINE 4448 G NK 300-0039 7 74 I EA 4" WIREWAY, 3FT B-LINE 4436 G NK BW-0107 7 75 2 EA 4" WIREWAY END CAP B-LINE 44 E NK 300-0028 7 76 1 4 1 EA 4" WIREWAY CONNECTER B-LINE 44 C. 300-0049 7 77 0.1 1 EA JIOFT WIREMOLD WIREMOLD ALA480OB-10 001-2327 8 78 3 EA 18FT WIREMOLD WIREMOLD ALA480OB-8 001-2327 8 WIREMOLD END CAP WIREMOLD ALA45106 001-2340 8 W1REMOLD BLANK COVER WIREMOLD ALA-BL 001-232q 6 WIREMOLD 4 HOLE COVER WIREMOLD ALA-BL (SEE E3) 001-232q 8 fffO0 WIREMOLD 2 HOLE COVER W1REMOLD ALA-BL (SEE E3) 001-232q 8 WIREMOLD RECEPTACLE PASS $ SEYMOUR 5358 800-0105 7,12 20 KVA UPS LIEBERT A54DONCYHNN8 50-I115UPS BYPASS SWITCH ILIEBERT NMBHW81/202816GI 8,12 MATERIALS LIST ITEM QTY UM DESCRIPTION MANUFACTURER MFR PART NUMBER TBB PART NUMBER NOTE 86 1 EA 70 KW GENERATOR GENERAC LPV700D 025-0321 6,1 87 1 EA 300A ATS, I0/3W, 240V GENERAC GTS STYLE 025-02% E 025-02% 8,12 88 1 EA SMOKE DETECTOR WITH AUXILIARY RELAY BRK 7010/RM4 100-0185 # 100-0184 7 Bq 2 EA 125A SUB -PANEL, 10/3W SQUARE D Q0124MI25 200-0149 8 qO 2 EA SUB -PANEL COVER SQUARE D QOC24US 200-0161 8 ql 2 EA GROUND BAR SQUARE D PKI5GTA 700-00lq 8 112 2 EA GROUND BAR ISOLATOR SQUARE D PKGTAB 200-01C17 8 93 1 EA BAIT WIRE SYSTEM HARDER MOTOGBALARMKT 001-2257 8 q4 q5 96 q7 98 qq 100 101 102 103 104 105 lob 107 3 EA GROUND STRAP BARS 108 3 EA GROUND STRAP COVERS 650-0048 I IOq 60 EA RIVETS 110 4 EA LIFTING LUGS 1 111 4 EA TIE DOWN PLATES 112 8 EA TIE DOWN BOLTS 113 B EA BLACK PLASTIC BASE PLUGS 114 10 EA FLOOR TILES I 115 1 1 1 EA ITUBE OF BRILLIANT WHITE CAULK 1 116 4 EA TUBES OF BEIGE DYMONIC CAULK 1 117 1 EA PINT CAN OF TELECOM BROWN PAINT 1 118 1 EA PINT CAN OF ELASTOMERIC COURSE PAINT 1 Ilq 25 EA 1/8" SHIMS FOR SHELTER SET 120 25 EA 1/4" SHIMS FOR 514ELTER SET MATERIAL LIST NOTES: I, SHIP LOOSE 2. PREINSTALL REMOVE FOR SHIPMENT 3. FABRICATED ITEM 4. PAINT - TELECOM BROWN 5. PAINT - TELECOM GRAY 6. PAINT - COLOR DESIGNATED 7. OR EQUIVALENT 8. NO SUBSTITUTIONS ALLOWED q. NO PART NUMBER SPECIFIED 10. MAY BE DELIVERED AT SIGHT 11. PROVIDED BY OTHERS 12. LABEL 13. QUANTITY ESTIMATED STAMPS AND SEALS No TwSCa( -Q�Q ,pu Q Za wZ�o � ��o�c�QCie�ao�g ,J IN F- nc w W uj 'A Q V/ V/ o J Q A�pr li. ON W F- X a G r r C w � m z �z4 ki w 0.. a DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Na ner SERIAL NUMBER: 1(003 -105 SCALE 24X36: NONE SKEET: C 2 _. 00 9'-1 3/4" WALL D 4'-2" MAX. 20 22 EXT EXT 66 ff------ in 88 ROW 3 WALL C 24' -0" 78 79 80 81 83 29 ROW 2 ROW 1 ` m ��■L,J■���■Ilfil� � ISO IIII ■ NMI Elio' � :, ■�■��lilll��■__■��II��I .III■ '■■ ■■�I �IIIIII('= ►� '■IIIIIIII! �IIIIIIII �� �••�I•�■III�I■11■Illllrj II!I■r 'IIII■I�� IIII■I(�� ': :;IIII■ !!lllllll■� IIIIIIII� WALL A FLOOR PLAN SCALE I/2"=1'-0" COMMERCIAL POWER: 120/240VAC, 300AMP SINGLE PHASE SERVICE, CONDUIT RUNS: I. ALL CONDUIT RUNS TO BE EMT UNLESS STATED OTHERWISE. 2. ALL CONDUIT RUNS TERMINATING AT SERVICE ENTRANCE EQUIPMENT SHALL CONTAIN BONDED BUSHINGS. 3, WIREWAYS CARRYING 3 OR MORE CURRENT CARRYING CONDUCTORS SHALL BE DERATED PER TABLE 310-15(5)(3)(o) OF APPLICABLE EDITION OF THE NEC. 4. CONDUIT FILL IS BASED ON CHAPTER 9, APPENDIX C OF THE NEC. CABLE LADDER: I. CABLE LADDER IS TO BE 8'-0" A.F.F. AND INSTALLED IN ACCORDANCE WITH ARTICLE 392 OF THE NEC LEVEL TO WITHIN 1/8" IN 10' OR SIMILAR. GROUNDING: I. ALL GROUNDING EXCEPT FOR CABLE LADDER TO CONFORM TO ARTICLE 250 OF THE NEC. 2. CABLE LADDER GROUNDING TO CONFORM TO ARTICLE 392.60 OF THE NEC, GENERAL NOTES: I. LABEL FACE OF ALL ELECTRICAL EQUIPMENT WITH PHENOLIC LABELS. BLACK WITH WHITE LETTERS. EXTERNAL BYPASS, TI, SDI, $ LAI. EXCEPTION SHALL BE ALL UPS EQUIPMENT SHALL HAVE PHENOLIC LABELS RED WITH WHITE LETTERS. EX UPSITPI, UPSI, WIREMOLD RECEPTACLES. 2. CONNECT ALARMS TO UPS WITH A DB25 PIN CONNECTOR. 3, CONNECT CIRCUITS PPI-22 $ PPI-24 TO THE EXTERIOR SURGE PROTECTOR AND LABEL. 4. COIL AND TAG 50' OF ALARM WIRE FOR GENERATOR ALARMS. S. CONNECT GENERATOR ALARMS TO THE DSWP03 SURGE PROTECTION MODULES. 6. COIL AND TAG 12" OF #10 WIRE FOR CIRCUITS, PPI-2 $ 4. 7. COIL 12" OF ALARM WIRE FOR TOWER LIGHT ALARM. TBI-25 $ 26. 8. COIL 50' OF #18 AWG FOR GENERATOR CONTROL WIRE. M WALL B STAMPS AND SEALS 4�=�mw�zz�d a�ZQ0rzw3.i�i a LO c ~i co 0 IUD co oN d v I O O O W CD O LO A O w � J �= Q Q cf) J J_ a O CDW qqT ON O X J O_ LL r r DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Wagner SERIAL NUMBER: 1603-105 SCALE " 2AX36: NONE SHEET: Al 2" OVERHANG TYP TEME NO SN01(ING q. I Po o Q Q Q 4'-5 7/8" 3'-4 1/4" 24-0" (TYP) (o" TYP T-8" FRONT ELEVATION (WALL A) SCALE: NONE REAR ELEVATION (WALL C) 5C41-E: NONE 11 O I/All I" NIPPLE FOR TOWER LIGHT ALARM I" NIPPLE FOR TOWER LIGHT ALARM I" PVC FOR BAIT WIRE (2) 3" PVC FOR TELCO ENTRY 1" PVC AT 45' #2 MECHANICAL LUG (2 PLACES) Lr14Yi L�JCi.J G�J m RVAI L____J I RIGHT ELEVATION (WALL B SCALE: NONE LEFT ELEVATION (WALL D SCALE: NONE EXTERIOR FINISH SCHEDULE ITEM SURFACE FINISH PAINT COLOR ROOF TROWELED SMOOTH SEALED, ELASTOMERIC COURSE TELECOM BROWN PAINT WALLS EXPOSED WASHED OKITE STAIN (2 COATS) - AGGREGATE DOORS STEEL, RATED PAINT TELECOM BROWN JOINTS AS FINISHED SEALED PER DETAILS SHEET TEL BROWN ELEVATION NOTES: I. SEE MATERIALS LIST FOR SHIPPED LOOSE ITEMS. 2. SEE MATERIALS LIST FOR DOOR HARDWARE. OR GENERATOR )R GENERATOR STAMPS AND SEALS W Z �oN��fl�a d zaEwZ zF Of J LL �1 C0 m Lu ■� w Q � � z � z w�za wry IL Ll DATE: 3/8M SALES MANAGER: D. Brunswick DRAWN BY: J. Wagner SERIAL NUMBER: 1603-10= SCALE " 24XBG: NONE SPEET: A2 LOOSE SAND OR GRAVEL BACKFILL NOTES: 15, 16 AND 17 SHIMS (TYP) (2) #4 REBAR AROUND PERIMETER WALL m #3 STIRRUP AT IS O.G. AROUND PERIMETER WALL SEE NOTE: 9 BUILDING FLOOR SYSTEM (2) #4 REBAR AROUND PERIMETER WALL =I v'UNDISTURBED OR COMPACTED SOIL NOTES: 5 AND 10 (3) #4 REBAR AROUND PERIMETER WALL BASE SECTION A -A SCALE: NONE TYPICAL EACH WAY SEE NOTES FOR SPECIFIC INFORMATION ON MATERIALS AND OTHER REQUIREMENTS #3 STIRRUP AT 18" O.C. AROUND PERIMETER WALL (3) #4 REBAR AROUND PERIMETER WALL BASE SEE NOTE: L005E SAND OR GRAVEL BACKFILL OPTIONAL VAPOR BARRIER SEE NOTE: 16 6"x6" MIN. PERIMETER CHAMFER SHIMS (TYP) (2) #4 REBAR AROUND PERIMETER WALL GRADE OI III Plll.1, I.1 z rn m CONCRETE SLAB -BUILDING FLOOR SYSTEM (2) #4 REBAR AROUND PERIMETER WALL TIE DOWN PLA1 (SEE DETAIL LI BELOW) #3 STIRRUP AT IV' O.C. AROUND UNDISTURBED OR PERIMETER WALL COMPACTED SOIL SEE NOTE: 9 NOTES: 5 AND 10 (3) #4 REBAR AROUND PERIMETER WALL BASE 2 SECTION A -A (OPTIONAL) SCALE: NONE TYPICAL EACH WAY SEE NOTES FOR SPECIFIC INFORMATION ON MATERIALS AND OTHER REQUIREMENTS A L A i 7 A-] FOUNDATION PLAN SCALE: 1 /2" =1'-0" SHIMS TYPICAL (SEE NOTE 12) A '_�_WWF 6x6 W2.9 x W2.9 IN SLAB, WHEN SLAB 15 USED � sHIMs #3 STIRRUP AT ANCHOR 18" O.C. AROUND (SUPPLIED BY PERIMETER WALL OTHERS) (3) #4 REBAR AROUND PERIMETER WALL BASE FRONT VIEW WALL IFTING TEE ASSEMBLY FLOOR ® 3/4" �/ pal J , BOLT a b FOUNDATION 3/4" X 3 3/8" SS ANCHOR MINIMUM I" CHAMFER (TYP.) (3) 1-1/8" DIAMETER HOLES NOTES: 1. PRIME AND PAINT THORO PRODUCTS COCOA, OR AS OTHERWISE SPECIFIED 2. THIS PART TO BE SNIPPED LOOSE WITH - BUILDING A (4) 3/8" X 6" X loll TIE DOWN PLATES 3 TIE DOWN DETAIL SCALE: 1-1/2" = I'-0" THIS DRAWING IS NOT FOR CONSTRUCTION SEE NOTE: 13 FOUNDATION NOTES: I. ALL FOUNDATION WORK BY OTHERS AND SUBJECT TO LOCAL INSPECTION AND APPROVAL. 2. FOUNDATION SURFACE SHALL BE LEVEL TO WITHIN +/- 1/8" PER 10 LINEAL FEET IN ANY DIRECTION. 3. FOUNDATION SHALL BE SQUARE TO WITHIN +/- 1/4" 4. BASE FOUNDATION WALL FOOTING MUST BE ESTABLISHED A MIN. OF 6" BELOW FROST LINE AND ON UNDISTURBED SOIL, 5. SOIL BEARING CAPACITY SHALL NOT BE LESS THAN 3000 PSF. 6. CONCRETE STRENGTH SHALL NOT BE LESS THAN 3000 PSI, AS DETERMINED BY ASTM G31,C39,072, LATEST REVISION. 7, REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, LATEST REVISION, 8. CONCRETE MIX DESIGN, BATCHING AND CONSTRUCTION PRACTICES SHALL CONFORM TO ACI 318, ACI 305R, ACI 306.1 LATEST REVISIONS. 9. DETAILING, FABRICATION AND PLACEMENT OF REINFORCING STEEL SHALL COMPLY WITH ACI 315, ACI 3181 ACI 306R, AWSDI.4 LATEST REVISIONS, AND WITH CRSI STANDARDS, 10. COMPACTION REQUIREMENTS TO BE DETERMINED BY ENGINEERING ANALYSIS OF SITE SPECIFIC DATA. 11. TIE DOWN PLATES, IF USED, MUST BE ENTIRELY ABOVE GRADE. 12. SHELTER MUST BE SHIMMED. 13. THIS INFORMATION IS PROVIDED FOR REFERENCE ONLY. FINAL DESIGN BASED ON SITE SPECIFIC DATA 15 THE RESPONSIBILITY OF THE SITE CONTRACTOR, 14. PROVIDE PROPER DRAINAGE AWAY FROM FOUNDATION AT GRADE, 15. SLAB REINFORCEMENT TO BE LOCATED IN UPPER THIRD OF SLAB. 16. BACKFILL DEPTH REQUIREMENTS TO BE DETERMINED BY ENGINEERING ANALYSIS OF SITE SPECIFIC DATA (4" MIN.). 17. BACKFILL DEPTH REQUIREMENTS TO BE DETERMINED BY ENGINEERING ANALYSIS OF SITE SPECIFIC DATA (4" MIN.). FOUNDATION LOADS: 2. DEAD LOAD:1375 PLF 3. LIVE LOAD: 2700 PLF STAMPS AND SEALS Qp[=� �-mwW Qzz ZsaZwZ Lp.L Qoa��-r'Oz �i3 .iYi za Q=�= �-zaiw�oao~ r f- a� od,NF W Ll2 mF� zf a w W In J W Q cn J 0 O ® cm � o0 r to 44 LL w w ■� �+ m a z�zQwz oQ wr C. Q DATE: 3/8/1 SALES MANAGER: D. Brunswic DRAWN BY: J. Wagnie 1603-IC SCALE 2436: NON SI IEET: A3 UTILITY SERVICE WITH GROUND 120/240 VAC 14/3W 60Hz (BY OTHERS, SUBJECT TO LOCAL CODES) SERVICE GROUND BONDED TO EXTERIOR GROUND RING WHERE ENTRY PORT 15 BONDED 120/240 vac 10/3W 60Hz 70kW UPS GROUND CONNECTED FROM GROUND ON UPS TERMINAL STRIP TO MASTER GROUND BAR. ONE -LINE WIRING DIAGRAM SCALE NONE NEUTRAL SHALL BE PULLED WHEN REQUIRED BY UPS MANUFACTURER UPS GROUND CONNECTED FROM GROUND ON UPS TERMINAL STRIP TO MASTER GROUND BAR. ONE -LINE DIAGRAM NOTES: I. ALL GROUNDING TO CONFORM TO ARTICLE 250 OF THE NEC 2. WIREWAYS CARRYING 3 OR MORE CURRENT CARRYING CONDUCTORS SHALL BE DERATED PER TABLE 310-15(15)(3)(d) OF THE APPLICABLE EDITION OF THE NEC 3. CONDUIT FILL 15 BASED ON CHAPTER q, APPENDIX C OF THE NEC 4. INCLUDE THE NEUTRAL TO GROUND BOND SCREW TO BE DONE ON SITE BY OTHERS. 5. MINIMUM CONDUIT SIZE SHALL BE i" (TRADE SIZE 16) SCHEMATIC LEGEND ON SITE BY OTHERS LUGGED LOAD CENTER ELECTRICAL EQUIPMENT LOAD CENTER WITH BREAKER TRANSFER SWITCH GENERATOR H \ F SURGE ARRESTOR PIG TAIL GROUND OFF-0 BY —0 �• 3 POSITION SWITCH NOR— O CIRCUIT BREAKER v / F INVERTER CONVERTER GROUND • CONNECTION STAMPS AND SEALS �oa�w�w�o 7dgN��o�t��u3pG�� z�aLwZpo��o t, 0 @ 1—izu Lu IrmLm Lo co Q 4 z0 Q) 04 O� CA L0 �C co +� I CCQ 0 �I O r�l c m W .co " a M/ NN W H � a W W Q cl) V J - O � 0 - a ®N 0. 2 co V t w r J w to J LL Lo A _ 0) � M o W --LLI Lij co c z w z � Q DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Na ner SERIAL NUMBER: 1603-105 SCALE 24X36: NONE S{IEET: E1 PP1 300A, 120/240VAC, 1(p/3W, 60Hz, M.BKR LOAD VOLT AMPS WIREBREAKER BREAKER WIRE VOLT AMPS LOAD A I B I ITRIPIP I I A I B UPS) FEED 8400 1 2 125 1 2 30 1 10 3 4 30 1 10 8 2 50 5 (350 2 8 I 20 g 10 60 2 4 11 12 13 14 15 1 1 12 1 20 15 16 20 1 12 12 2 15 17 18 20 1 12 Ig —40 20 20 1 12 12 1 15 21 22 20 1 12 23 24 20 1 12 25 26 27 28 2g 30 31 32 1 33 34 35 36 I 2 125 37 5 40 WIRE TYPE TO BE THHN UNLESS NOTED LOAD OTHERS AS REQUIRED 250 TOWER LIGHT 8400 250 TOWER LIGHT HVAC #1 3300 3300 HVAC #2 3300 3300 SPARE 60 SURGE ARRESTOR BLANK 60 BLANK SPARE LIGHTS INT It EXT 1110 160 BAIT WIRE POWER FAIL 120 1260 RECEPTACLES 120 360 RECEPTACLE GFCI SMOKE DETECTOR 120 120 BLOCK HEATER* BLANK 120 BATT. CHARGER* BLANK BLANK BLANK BLANK BLANK BLANK BLANK BLANK BLANK BLANK BLANK BLANK UPS2 FEED 8400 BLANK 8400 BLANK VA PER PHASE 20340 21330 4gg0 4270 VA PER PHASE + CALCULATED AT 125% CONNECTION BY OTHERS $ GROUND FAULT PROTECTION FOR CONTINUOUS BY 25330 25600 TOTAL VA PER PHASE 211 213 AMPS PER PHASE 50.9 TOTAL KVA 234 AMPS X 110% UPS1TP3 125A, 120/240VAC, 1(p/3W, 60Hz, M.BKR LOAD VOLT AMPS WIRE BREAKER BREAKER WIRE VOLT AMPS LOAD A B P TRIP TRIP P A B ROW I RECEPT #1 ROW I RECEPT #3 ROW I RECEPT #5 ROW I RECEPT #7 ROW 1 RECEPT #q ROW I RECEPT #11 ROW I RECEPT #13 ROW 1 RECEPT #15 BLANK BLANK BLANK TELCO RECEPT #1 VA PER PHASE 180 180 80 180 720 1 1 180 180 180 180 80 900 1 12 12 12 12 12 12 12 12 12 I 20 I 1 20 3 I 20 5 1 20 7 1 20 9 1 20 11 1 20 13 1 20 15 17 ig 21 I 20 23 WIRE TYPE TO BE THHN 2 20 1 4 20 1 6 20 I 8 20 1 10 20 1 12 20 1 14 20 1 16 20 1 18 20 22 24 20 1 UNLESS NOTED 12 12 12 12 12 12 12 12 12 1 180 150 150 I80 1 720 1440 12 ROW I RECEPT #2 150 ROW I RECEPT #4 ROW 1 RECEPT #6 180 ROW I RECEPT #8 ROW I RECEPT #10 160 ROW I RECEPT #12 ROW I RECEPT #14 160 ROW I RECEPT #16 BLANK BLANK BLANK 180 TELCO RECEPT #2 900 VA PER PHASE 1800 TOTAL VA 15 TOTAL AMPS/PHASE 3.2 TOTAL KVA 17 AMPS X 110% UPS1TP1 200A, 120/240VAC, 1(0/3W, 60Hz, M.BKR LOAD VOLT AMPS ''I I'': BREAKER WIRE VOLT AMPS LOAD A B P ITRIP ITRIP1 P I I A B ROW 3 RECEPT #1 180 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 1 20 1 1 1 20 3 1 1 1 20 5 1 20 7 1 1 1 20 g 1 1 20 it 1 20 13 1 20 15 1 20 17 1 20 Ig 1 20 21 1 20 23 1 20 25 1 20 27 1 20 2q 1 20 31 33 35 37 39 WIRE TYPE TO BE THHN 2 20 1 4 20 1 6 20 1 8 20 1 10 20 1 12 20 1 14 20 1 16 20 1 18 20 1 20 20 1 22 20 1 24 20 1 26 20 1 28 20 1 30 20 1 32 20 1 34 36 38 40 UNLESS NOTED 1 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 1 1&0 ROW 3 RECEPT #2 ROW 3 RECEPT #3 180 180 ROW 3 RECEPT #4 ROW 3 RECEPT #5 150 180 ROW 3 RECEPT #6 ROW 3 RECEPT #7 180 180 ROW 3 RECEPT #8 ROW 3 RECEPT #q 180 180 ROW 3 RECEPT #10 ROW 3 RECEPT #11 180 180 ROW 3 RECEPT #12 ROW 3 RECEPT #13 180 I80 ROW 3 RECEPT #14 ROW 3 RECEPT #15 180 180 ROW 3 RECEPT #16 ROW 2 RECEPT #17 180 160 ROW 2 RECEPT #18 ROW 2 RECEPT #19 180 180 ROW 2 RECEPT #20 ROW 2 RECEPT #21 180 180 ROW 2 RECEPT #22 ROW 2 RECEPT #23 180 180 ROW 2 RECEPT #24 ROW 2 RECEPT #25 180 180 ROW 2 RECEPT #26 ROW 2 RECEPT #27 180 1130 ROW 2 RECEPT #25 ROW 2 RECEPT #2q 180 180 ROW 2 RECEPT #30 ROW 2 RECEPT #31 180 180 ROW 2 RECEPT #32 BLANK BLANK BLANK BLANK BLANK BLANK BLANK BLANK VA PER PHASE 1 1440 1 1440 1440 VA PER PHASE K240 2880 TOTAL VA 24 TOTAL AMPS/PHASE 5.8 TOTAL KVA 26 AMPS X 110% UPS2TP4125A, 120/240VAC, 1(p/3W, 60Hz, M.BKR LOAD VOLT AMPS WIREBREAKER BREAKER WIRE VOLT AMPS LOAD A B P TRIP TRIP P A B ROW I RECEPT #1 ROW 1 RECEPT #3 ROW 1 RECEPT #5 ROW I RECEPT #7 ROW I RECEPT #q ROW 1 RECEPT #11 RQW 1 RECEPT #13 ROW 1 RECEPT #15 BLANK BLANK BLANK TELCO RECEPT #3 VA PER Fi�ASE 180 180 180 180 720 180 180 180 180 180 900 1 12 12 12 12 12 12 12 12 12 1 20 1 20 1 20 1 20 1 20 1 20 1 2013 i 1 20 I 20 WIRE TYPE 1 3 5 7 q 11 15 17 lg 21 23 TO BE THHN 2 20 1 4 20 1 6 20 1 8 20 1 10 20 1 12 20 1 14 20 1 16 20 1 18 20 22 24 20 1 UNLESS NOTED 12 12 12 12 12 1 12 1 12 12 12 160 ROW 1 RECEPT #2 150 ROW I RECEPT #4 180 ROW I RECEPT #6 160 ROW I RECEPT #8 180 ROW 1 RECEPT #10 180 ROW 1 RECEPT #12 150 ROW I RECEPT #14 180 RQW I RECEPT #16 BLANK BLANK BLANK 180 TELCO RECEPT #4 720 900 VA PER PHASE 1440 1800 TOTAL VA 12 15 TOTAL AMPS/PHASE 3.2 TOTAL KVA 17 AMPS X 110% ` UPS2TP2 200A, 120/240VAC, 1(p13W, 60Hz, M.BKR LOAD VOLT AMPS WIREBREAKER JBREAKERJNIREJVOLT AMPS LOAD A B I I P TRIP1 TRIP1 P I A IB ROW 3 RECEPT #I 180 12 12 12 12 12 12 12 12 12 12 12 12 12 12 1 20 1 1 20 3 1 20 5 1 20 7 1 20 g 1 20 11 1 20 13 1 20 15 1 20 17 1 20 lg 1 20 21 I 20 23 1 20 25 1 20 27 1 20 2q 1 20 31 33 35 37 3g WIRE TYPE TO BE THHN 2 20 1 4 20 1 6 JO 1 8 20 1 10 20 1 12 20 1 14 20 1 16 20 1 18 20 1 20 20 1 22 20 1 24 20 1 26 20 1 28 20 1 30 20 1 32 20 1 34 36 Be 40 UNLESS NOTED 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 180 ROW 3 RECEPT #2 ROW 3 RECEPT #3 180 180 ROW 3 RECEPT #4 ROW 3 RECEPT #5 180 180 ROW 3 RECEPT #6 ROW 3 RECEPT #7 180 180 ROW 3 RECEPT #8 ROW 3 RECEPT #q 180 ISO ROW 3 RECEPT #10 ROW 3 RECEPT #11 180 180 ROW 3 RECEPT #12 ROW 3 RECEPT #13 180 180 ROW 3 RECEPT #14 ROW 3 RECEPT #15 150 180 ROW 3 RECEPT #1(o ROW 2 RECEPT #17 180 180 ROW 2 RECEPT #18 ROW 2 RECEPT #19 180 180 ROW 2 RECEPT #20 ROW 2 RECEPT #21 180112 180 ROW 2 RECEPT #22 ROW 2 RECEPT #23 I80 ROW 2 RECEPT #24 ROW 2 RECEPT #25 15012 180 ROW 2 RECEPT #26 ROW 2 RECEPT #27 I80 ROW 2 RECEPT #28 ROW 2 RECEPT #29 I80 180 ROW 2 RECEPT #30 ROW 2 RECEPT #31 180 180 ROW 2 RECEPT #32 BLANK BLANK BLANK BLANK BLANK BLANK BLANK BLANK VA PER PHASE 1440 1440 1440 VA PER PHASE K24 2880 TOTAL VA 24 TOTAL AMPS/PHASE 5.8 TOTAL KVA 26 AMPS X 110Y Arm` I= rr- 'I 'b Lo to 9 �0 ...r� z0 en O � N O W to LO �co 0 cv d U I 0 W o0 cv� co 0 4 X W V) 00 J W co W Z 2= a 0® Q 0 tV 0. t� 2 J 00 r W r CD J me LL n A � M C) W � m < z � z l-Wi 3 d Q (Y (Y IL Q DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Na ner SERIAL NUMBER: 1603-105 SCALE 24X36: NONE SHEET: E1.1 ALARM NOTES: L ALL ALARMS TO BE NORMALLY CLOSED. 2. UNSHIELDED SINGLE TWISTED PAIR WIRE IN STANDARD. TO TBG IN BYPASS ALARM BLOCK #1 (NC -RED) ALARM BLOCK #2 ALARM BLOCK #3 TO TBG IN BYPASS BRIDGE CLIP (TYP) (C-BLK) RED 1 0 0 0 0 1 0 0 0 0 DOOR ALARM DAl-NC 2 2 GEN PRE HIGH COOLANTS( GP#CT5-NC 2 C #22 SOLID DAI-C WHITE 0 o WHITE 0 0 0 o TEMP SHUTDOWN l GPNCTS-C 0 0 0 o 3 o 0 0 o RED 3 o #22 SOLID 3 0 0 0 0 C DOOR ALARM GEN ROOM ff 1 DA2-NC 4 UPS2 RUN J r UPSI 12-NC 4 GEN LOW COOLANT 1 GLCTW-NC #22 SOLID l DA2-C 0 0 0 0 o #22 SOLID l UPSI 14-C WHITE o TEMP WARNING 1 GI-C 4 0 0 0 0 o C 5 5 #22 SOLID 5 [ RED O RED O 0 RED 0 0 SMOKE DETECTOR r 1 DI -NC 6 UP52 BYPASS J r UPSI 12-NC 6 E�jGEN LOW COOLANT LEVEL GLTL-NC 6 tt22 SOLID l DI-C WHITE � � tt22 SOLID 1 UPSI 17-C WHITE O � tt22 SOLID GLTL-C WHITE o 0 �-1 7 �] O � o RED 7 � � RED 7 O 0 [ FIRE PANEL TROUBLE NPT-NC { $ UP52 POWER FAIL { UPSI I2-NC 6 GEN COOL TEMP FAIL { GCTSF-NC 8 tt22 SOLID NPT-C O 0 O O tt22 SOLID UP51 II-C WHITE tt22 SOLID GCTSF-C WHITE 0 RED 9 � O RED 9 0 O RED 9 O O � r L HIGH/LOW TEMP r J NTA-NC 10 UPS2 FAIL J UPSI 12-NC 10 GEN HIGH BATT VOLTAGE GNBVW-NC 10 tt22 SOLID l PTA-C WHITE 0 0 tt22 SOLID l UPSI 14-C NHITE = #22 SOLID GLBVW-G NHITE 0 0 11 � 0 0 o RED 11 0 O RED 11 0 0 � HIGH/LOW HUMIDITY PHA -NC 12 UP52 LOW BATTERY UPSI 12-NC 12 GEN LOW BATT VOLTAGE { GLBVW-NC 12 tt22 SOLID HHA-C 0 tt22 SOLID UPSI 17-C NHITE #22 SOLID GLBVW-C WHITE O O �E RED 13 0 0 RED 13 � � 0 13 � � � 0 O [ AC POWER FAIL J PFA-NC 14 UPS2 SUMMARY { UPSI 12-NC 14 GEN #22HSOLID { GNF-NC 14 C #22 SOLID l PFA-C WHITE #22 SOLID UPSI 11-C WHITE GNF-C O O O 0 o RED 15 0 0 15 0 0 0 o C SURGE ARRESTOR #2 J LA2-NC GEN RUN J GRN-NC 16 GEN LOW FUEL SHUT GLFS-NC 16 [ tt22 SOLID 1 LA2-00 o tt22 SOLID l GRN-C WHITE 0 0 tt22 SOLID GLFS-C 0 0 0 o 0 o RED 17 o a RED 17 0 0 C #VAC FAIL 1 NVAC LO-NC GEN FAIL GFL-NC 18 GEN LOW FUEL { GLF-NC 18 C tt22 SOLID 1 NVAC LO-00 o tt22 SOLID GFL-C WHITE 0 0 tt22 SOLID GLF-C WHITE 0 0 123 0 0 o RED 19 0 0 19 O [ IST ALARM JFIRE 5YS-NC GEN DISABLE { GDA-NC 20 GEN DL/##22TSOLID O GGDLFTINC 20 [ #22 SOLID l FIRE SYS-00 0 0 tt22 SOLID GDA-C WHITE 0 o IDI o 0 0 o 21 0 0 0 o 21 0 0 0 o GEN ROOM IST ALARM i(FIRE SYS-NC GEN OVERSPEED { GOS-NC 22 GEN DL/LP TANK 2 { GDLFT2-NC 22 C #22 SOLID l FIRE SYS-C 0 0 0 #22 SOLID GOS-G 0 0 0 0 #22 SOLID GDLFT2-C 0 0 o a 0 0 0 23 0 0 0 0 23 0 0 0 o RF LN DEHYDRATOR (DENYDTR-NC 24 GEN UNDERSPEED GUS-NC 24 GEN DL/LP TANK 3 j GDLFT3-NC 24 C tt22 SOLID SOLID l DENYDTR-C O O O 0 tt22 SOLID GUS-C 0 0 0 0 1 tt22 SOLID ll GDLFT3-C 0 0 0 0 RED 25 0 0 25 0 0 0 0 25 0 0 0 o C TOWER LIGHT FAIL r J TWR LGT-NC 26 GEN OVERCRANK J GOG-NC 26 r GEN DL/LP TANK 4 J GDLFT4-NC 26 C tt22 SOLID 1 TWR LGT-C WHITE O O #22 SOLID l GOC-G tt22 SOLID t GDLFT4-C O O O RED 27 0 0 0 0 0 0 7 O L_ SURGE ARRESTOR #IJ LAI-NC 28 GEN RPM SENSOR LOSS 1 GRSL-NC 28 GEN REMOTE START GRS-NC 28 [ tt22 SOLID l LAI-C WHITE o 0 tt22 SOLID l GRSL-G 0 0 0 0 tt22 SOLID GRS-C o 0 � RED 29 O O 29 O O � O 29 O O O O C GROUND BAR THEFT J GND-NC 30 GEN OVER VOLTAGE J GOV-NC 30 GEN REMOTE STOP f GRSP-NC 30 C #22 SOLID l GND-C W#ITF 0 #22 SOLID l( GOV-C #22 SOLID GRSP-C 0 0 o 31 0 0 0 O O O 32 GEN UNDER VOLTAGE) GUV-NC 31 r GEN HIGH TEMPI GHT-NC 31 C 0 0 0 0 o #22 SOLID 1 GUV-G O #22 SOLID 1 GNT-C O 0 O 33 O O O O 33 33 O O O C TO TBG IN BYPASS GEN OVER FREQ GOF-NC (NC -RED) 34 O O O #22 SOLID { GOF-C 34 O O 0 0 34 O O O O C TO TBG IN BYPASS 35 35 35 (G-BLK) 36 0 0 0 o GEN UNDER FREQ { GUF-NC 36 0 0 0 o ATE, NORMAL POWER { TBI-I-NC RED 36 0 0 0 0 o #22 SOLID GUF-C 0 0 0 0 #22 SOLID TB1-3-C WHITE 0 0 37 0 0 37 0 0 0 o RED 37 0 o C GEN LOW OIL PRES { GLOP -NC 38 ATS STANDBY POWER { TBI-G-NC 38 TB #15 WHITE E39 0 0 0 o tt22 SOLID GLOP-C O O O #22 SOLID TBI-B-C WHITE o RED 0 39 0 0 o o 39 o 0 0 E UPSI RUN1 r UP51 12-NC 41 GEN HIGH OIL PRES { CHOP -NC 40 ATS REMOTE START { RS-NC 41 0 #22 SOLID l UPSI 14-C WHITE 0 #22 SOLID GHOP-C o a o o tt22 SOLID PS-C 0 o a o RED 41 o 41 0 0 0 o 41 0 o o [ UPSI BYPASS � UPSI 12-NC 42 GEN OIL PRES FAIL � GOPF-NC 42 r TRANSFER COMPLETE 1 75I-2-NC 42 C #22 SOLID UPSI 17-C NHITE 0 0 #22 SOLID GOPF-G o o tt22 SOLID l TBI-4-C o O O RED 43 0 0 43 0 0 0 0 43 o 0 0 0 [ UPSI POWER FAIL 1 UPSI 12-NC 44 f GEN OIL TEMP FAIL J GOTF-NC 44 E #22 SOLID l UPSI II-C NHITE 0 o tt22 SOLID l GOTF-C4 0 0 0 0 0 0 0 o RED 45 45 0 0 0 0 45 0 0 0 o C UPSI FAIL UPSI 12-NC GEN PRE HIGH OIL GPNOPW-NC #22 SOLID f UPSI 14-C WHITE Al0 0 PRESSURE WARNING GP#OPW-C 46 0 0 0 0 0 46 0 0 0 0 0 C RED 0 o tt22 SOLID 47 0 o a o 47 0 0 0 0 UPSI LOW BATTERY UP51 12-NG GEN PRE HIGH OIL GPNOTW-NC 422 SOLID f UPSI I7-C NHITEO O TEMP WARNING GPHOTW-G 48O O O 48 [ V tt22 SOLID 49 49RED� O � O 0 �UPSI SUMMARY f UPSII2-NC GEN START INHIBIT1 GSIOP-NC[#22 50 50 SOLID UP51 II-CWHITE 0 OIL PRESSURE i GSIOP-C O O O O O 0 0 O #22 SOLID CONNECTOR CONNECTOR CONNECTOR AT BLOCK AT BLOCK AT BLOCK STAIYPS AND SEALS ALARM BLOCKS SCALE: NONE a�=�mW�'ZQ Zmi 9i w3�i aQazapp[� �-ZaEwZpO� ~ zwaqtyu�_ Foal Wi Z F iv w W W Q J U) Q Do ON Q O � ^ � J Q r r W J LL 'O V •� w w C0 CID Q � � z Z L O Q CL Ca DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Wagner SERIAL NUMBER: 1603-105 SCALE 24X36: NONE SHEET: El m2 CONNECT EQUIPMENT GROUND TO GROUND BAR HERE TO THIS LOCATION ONLY Al id SERVICE GROUND COIL EXIT INSTALL GBKI4 TO SIDE OF ENCLOSURE WITH #10 BOLTS AND NUTS. (REMOVE PAINT AND USE NO-OX) GROUND EACH DSWPH03 TO GBKI4. CONNECT #2 TO THE ENCLOSURE WITH 2-HOLE LUG (PLACE #2 AS CLOSE AS POSSIBLE TO THE #10 BOLTS) AND RUN AS SHOWN TO THE MGB AND CONNECT WITH A 2-HOLE LUG. ❑ ❑ ®0 O ❑ ❑ a E 101 #2 GREEN TO UPS TERMINAL STRIP WALL D 4'-I" —T I' -8" lr� CONNECT CABLE LADDER TO GROUND BAR MERE TO THIS LOCATION ONLY ROW 3 WALL C 3'-0" ROW 2 ROW I M � ®I I® ®I I — II 11 p II 11 11 U II loom 11 �MISM MOM!� I u u e I) c N N B � 11 � O C N N c w L J FolI �I ❑ ' lIX3> I I II WALL A GROUNDING LAYOUT SCALE 1/2"=1'-0" CABLE LADDER: L CABLE LADDER IS TO BE 8'-0" A.F.F. AND INSTALLED IN ACCORDANCE WITH ARTICLE 392 OF THE NEC LEVEL TO WITHIN 1/8" IN 10' OR SIMILAR. GROUNDING: I. ALL GROUNDING EXCEPT FOR CABLE LADDER TO CONFORM TO ARTICLE 250 OF THE NEC. 2. CABLE LADDER GROUNDING TO CONFORM TO ARTICLE 392.60 OF THE NEC. #2 BARE STRANDED COPPER IPGB ON 4" PANDUIT STANDOFFS EVERY 24" (PRT. #PP2S-5I0-C), CONNECTED TO MASTER GROUND BAR. ALL CONNECTIONS SHALL BE MADE WITH BURNDY COMPRESSION FITTINGS AND ALL BENDS SHALL BE 8" MIN. RADIUS. WALL B v ww p? z W W Z W Z w eQoE>-op[Qz a z=� w NQ�a�uEa�� y}C' 0.'VUOQ3j zF LL F W W J — C a� - J - C 0 o 2 C ON �X O- 2 oo — C r c: J LL TE: 3/8/1� SALES MANAGER: D. Brunswick DRAWN BY: J. Wagner SERIAL NUMBER: 1603-10y SCALE 24X36: NONE SHEET: E2 INSULATOR CEILING ® THREADED ROD \ CABLE LADDER (8) 1/2" FLAT WASHER (8) 1/2" LOCK WASHER (8) 1/2"-11 NUT BRACKET, HANGER, PLATE WITH 129/32" SLOT LADDER INSTALLATION DETAIL SCALE: NONE EXTENSION BARS THROUGH WALL WALL MOUNTING BRACKET 0 0 19, 0 p 0 0 0 0 0 B, O O00� 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ® 0 0 0 ® 0 0 GROUND BAR INTERIOR GROUND BAR DETAIL SCALE: NONE 1/4"-20 2 HOLE LUG HEX BOLT #6 GREEN �I/4" FLAT WASHER PRIMARY GROUND" �`�-1/4" LOCK BAR/METAL WASHER ENCLOSURE LOCK NUT HEX BOLT -LOCK WASHER I. SELECT BOLT LENGTH TO PROVIDE A MINIMUM OF TWO EXPOSED THREADS, 2. BURNISH MOUNTING SURFACE TO REMOVE PAINT IN THE AREA OF LUG CONTACT. 3. APPLY ANTI -OXIDANT COMPOUND TO MATING SURFACE OF LUG AND WIPE CLEAN EXCESS COMPOUND. 4. ONLY ONE LUG PER SET OF BOLTS. GROUNDING CONNECTION SCALE: NONE 3/4" PVC FOR GROUND ACCESS I PVC CAST IN WALL 450 PVC NIPPLE DETAIL SCALE: NONE (INSTALLED ON SITE) EXTERIOR GROUND BAR DETAIL SCALE: NONE CABLE LADDEP CORNER HOLE LUG #6 GREEN 1/4" 55, 1/4"-20 TO MGB #6 GRE GROUN #6 GRE RACK TO Ml EQUIPME GROUND B #6 GREEN GROUND B (TYI EXAMPLE 1 EXAMPLE 2 I. IF RACK HAS A GROUND BUS BAR (EXAMPLE 1 8 2) ALL EQUIPMENT GROUNDS SHALL BE CONNECTED TO THE EQUIPMENT BUS BAR VIA #/n GRN. A #2 GRN SHALL THEN BE TAKEN FROM THE GROUND BUS BAR TO THE EQUIPMENT GROUND BUS CONDUCTOR. 2. ALL EQUIPMENT GROUND SPLICES SHALL BE TAPED WITH GREEN TAPE. EQUIPMENT GROUNDING ELEVATION EXAMPLE REFER TO ONLY WHEN EQUIPMENT IS INSTALLED. VIEWED FROM REAR OF EQUIPMENT SCALE: NONE GROUND USE WHITE BASE AS TEMPLATE t DRILL 1/4" HOLES 6"O.C. STAGGERED FROM LEFT TO RIGHT AND SECURE DURO-LAST VINYL BASE WITH 1/4"XI-1/4" NYLON ANCHOR 4 VINYL BASE DURO-LAST #1571 (WHITE) FASTEN WITH NYLON DRIVE RIVETS BOLT (NO METAL TO BE USED) K WASHER 2" GROUND STRAP BROWN VINYL COVER DURO-LAST #1572 (TAN) GROUND RING (REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS) a`. d BUS BASE It COVER SHALL EXTEND G" BELOW GRADE, CUT OFF EXCESS GROUND BAR/STRAP/COVER DETAIL SCALE: NONE TO IPGB RING 11 METAL DOOR FRAME 551 1/4"-20 BOLT II WITH FLAT WASHER 2 HOLE LUG G 2" REF. T ItB 54205 ACROSS EVERY LADDER TO LADDER CONNECTION CABLE LADDER BOND DETAIL SC:` -LE: NONE DOOR 1/4" X I" BOLT t 1/4" FLAT WASHER HINGE LINE DOOR BONDING STRAP r%e%f%o Qf1Al1'liRlf_ 11CTA ll SCALE: NONE "C" TAP YC2C4 1/B" MIN. 1/4" MAX. 8" RADIUS ALL AXES #2 STRANDED NON -JACKETED GREEN TO GROUND ITEM-- IPGB RING GROUND TAP SCALE: NONE VTrl_T ]gawVDIRT NEWTON BRACKET 2105 LOCATE ON CABLE LADDER EVERY 18" #2 STRANDED GREEN SECURE TO BRACKET WITH TY-WRAPS NEWTON BRACKET GROUND SCALE: NONE BRACKET PANDUIT PP25--510-C TY-RAP Tt5 #10 X 1-1/2" HHW PLATED SHEET METAL SCREW #2 STRANDED' NON -JACKETED (2) TY-RAP T48 TY24M FEED ONE OVER AND ONE UNDER IPGB GROUND INSTALLATION SCALE: NONE GROUNDING NOTES: I. USE NO-OX AT ALL GROUND TERMINATIONS. 2. IN PLACES WHERE THE GROUND BUS WIRE IS LESS THAN 2" FROM METALLIC OBJECTS AND NOT BONDED, NEATLY TAPE THE SECTION WITH GREEN TAPE. WHERE NECESSARY, REMOVE THE TIE WRAPS (AND RE -INSTALL AFTER TAPING) AND TAPE C-TAPS FIRST AND THEN TAPE PAST THEM IN A CONTINUOUS WRAP. 3. PLACE HEAT SHRINK TUBING ON GROUND BAR PIGTAILS THAT GROSS WALL MOUNTED CONDUIT. 4. ALL DOORS TO BE GROUNDED TO THEIR FRAMES WITH WELDING WIRE. USE #2 GAUGE WELDING WIRE AND STANDARD BURNDY TWO -HOLE LUGS. PLACE A 2" BAND OF GREEN TAPE AT EACH END OF THE JUMPER. 5. INTERIOR PERIMETER GROUND BUS (IPGB): #2 BARE STRANDED COPPER AROUND INSIDE PERIMETER OF BUILDING WITH EACH END LUGGED TO THE GROUND BAR. 6. BONDING JUMPERS: #6 GREEN STRANDED INSULATED WIRE FROM METALLIC EQUIPMENT TO IPGB AND ACROSS LADDER RACK SPLICES/CROSSES/TEES, 7. EQUIPMENT GROUND BUS: #2 GREEN RAN OUTSIDE EACH RUN OF CABLE LADDER WITH NEWTON CLIPS (#2106G). "G" TAP #2 STRANDED YC2C2—\ GREEN „ #2 STRANDED 1/8 MIN GREEN 1/4" MAX. 8" RADIUS ALL AXES EQUIPMENT GROUND TAP SCALE: NONE STAMPS AND SEALS u w z os'd wr8 °� }�F f�l w F mnftn�_@Q S 'imp t o zo ca �z A4 c ®w ftS d Qr' 0 J� cv � I co 0 �+ U I O O O rTl G CD WGo � q a � W J v+ W P o aco O Z O N z F OX 00 0 ce P r DATE: 3/5/16 SALES [MANAGER: D. Brunswick DRAWN BY: J. Wa ner SERIAL NUMBER: 1603-105 SCALE 24X36: NONE SHEET: Ell k uw.w 5/32" DIA. l �� (TYP 8 PLACES) 11A. NOLE (TYP 4 PLACES) WIREMOLD SIMPLEX COVER SCALE: NONE 2 EACH REQUIRED 5/32" DIA. ,, 1_ (TYP 8 PLACES) _ _.A. HOLE (TYP 4 PLACES) WIREMOLD SIMPLEX COVER SCALE: NONE EMT CONNECTOR EMT CONDUIT � RIGID COUPLING CABLE LADDER J 90° LIQUIDTITE CONNECTOR STRAIGHT LIQUIDTITE CONNECTOR CEILING �— LIQUIDTITE CONDUIT WIREMOLD 4 WIREMOLD CONNECTION SCALE: NONE (DO NOT RUN CONDUITS THROUGH CABLE LADDER) (CONDUIT SHALL LINE-UP WITH BLANK COVER PLATE) REAR WALL �TOP TOP — CEILING 3"x3"xl/4" ALUMINUM ANGLE 114" BOLT AND NUT )R (USE 2 EACH EMOLD RUN) WIREMOLD WIREMOLD INSTALLATION DETAIL SCALE: NONE INSULATORS SHALL BE PLACED AS CLOSE TO CABLE LADDER AS POSSIBLE CIRCUIT #I CIRCUIT #17 CIRCUIT CIRCUIT #2 CIRCUIT #I8 CIRCUIT CIRCUIT #3 CIRCUIT #Iq CIRCUIT CIRCUIT #4 CIRCUIT #20 CIRCUIT CIRCUIT #1 CIRCUIT #17 CIRCUIT #2 CIRCUIT #18 CIRCUIT #3 CIRCUIT #lq CIRCUIT #4 CIRCUIT #20 CIRCUIT #5 CIRCUIT #21 CIRCUIT CIRCUIT #6 CIRCUIT #22 CIRCUIT CIRCUIT #7 CIRCUIT #23 CIRCUIT CIRCUIT #84 CIRCUIT #24 CIRCUIT —STOP IT #1 IT #2 IT #3 IT #4 24 EACH REQUIRED CIRCUIT #q CIRCUIT #10 CIRCUIT #5 CIRGUIT #6 CIRCUIT #7 CIRGUIT #8 CIRCUIT #21 CIRCUIT #22 CIRCUIT #23 CIRCUIT #24 CIRCUIT 325 CIRCUIT #26 CIRCUIT #q CIRCUIT #10 CIRCUIT #5 CIRCUIT #6 CIRCUIT #7 CIRCUIT #8 CIRCUIT #11 CIRCUIT #27 CIRCUIT #11 CIRCUIT #12 CIRCUIT #28 CIRCUIT #12 CIRCUIT #q CIRCUIT #25 CIRCUIT #q CIRCUIT #10 CIRCUIT #26 CIRCUIT #10 CIRCUIT #11 CIRCUIT #27 CIRCUIT #II CIRCUIT #12 CIRCUIT #28 CIRCUIT #12 CIRCUIT #13 CIRCUIT #29 CIRCUIT #13 CIRCUIT #14 CIRCUIT #3 CIRCUIT #14 GROUND TO BE PLACED TOWARD THE TOP CIRCUIT #15 CIRCUIT #31 CIRCUIT #15 (TOP HALF OF WIREMOLD) CIRCUIT #16 CIRCUIT #32 CIRCUIT #16 WIREMOLD COVER SHALL BE LABELED CIRCUIT #13 CIRCUIT #2q CIRCUIT #13 WITH THE PANEL # IN THE CENTER, /uPSITPI CIRCUIT #14 CIRCUIT #30 CIRCUIT #14 AND THE CIRCUIT # UNDER EACH CIRCUIT #15 CIRCUIT #31 CIRCUIT #15 RECEPTACLE AS SHOWN BELOW: CIRCUIT #16 CIRCUIT #32 CIRCUIT #16 UPSITPI UPS2TP2 UPS2TP2 UPSITPI UPSITP3 UPS2TP4 /a ea la la ROW 3 ROW 2 ROW I 0 0 0 0 o Oa a o 0 Da Oa Oa 0 0 0 0 0 0 0 CKT #1 GKT #2 CKT #3 CKT #4 GROUND TO BE PLACED TOWARD THE BOTTOM WIREMOLD CIRCUIT LOCATION (BOTTOM HALF OF WIREMOLD) SCALE: NONE SIMPLEX RECEPTACLE _ORIENTATION SCALE: NONE RECEPTACLES TO BE PLACED ON REAR SIDE OF EQUIPMENT. UPS] CIRCUITS TO BE ON TOP HALF OF WIREMOLD. UPS2 CIRCUITS TO BE ON BOTTOM HALF OF WIREMOLD. STAMPS AND SEALS Lo 'Cf co 00 4 z0 OQ �� ®� � O> O Lo q � 0�I O CX? co W co Lo N w W m J ui Q to J 0 J O® � ®N bo 1 r r DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Na ner SERIAL NUMBER: 1603-105 SCALE 24X36: NONE SHEET: E 3 )IL 50' OF GENERATOR )NTROL AND ALARM RES WALL D Al 4'-2" MAX. lk F WALL C vi u ■il�■i�����ll�� 11 11 11 I :, NMI IWO ■ � ■ � 1 ■I/! �I!� III I I� � � ■■■1�1�- ;�� ■III, mol■L,J■���■Ilril�■�■�■�1Ilrml Emmillmilim : ■■ ■■�� ■iillilfl- � �■IIIIIII!� ■ I �IIIIIIII -i ������1■III■�■����Illlrl ��III■I- IIII■Ir�� �,I I r , j� 11 1 .;III!■ !!lllllll■� IIIIIIII■ I I 111 III■r'I 1 11 —._�. unui���innn��■�ni�lll��� WALL A ELECTRICAL DIMENSIONS SCALE 1/211=1'-0" COMMERCIAL POWER: I 120/240VAC, 300AMP SINGLE PHASE SERVICE. I CONDUIT RUNS: I. ALL CONDUIT RUNS TO BE EMT UNLESS STATED OTHERWISE. 2. ALL CONDUIT RUNS TERMINATING AT SERVICE ENTRANCE EQUIPMENT SHALL CONTAIN BONDED BUSHINGS. 3. NIRENAYS CARRYING 3 OR MORE CURRENT CARRYING CONDUCTORS SHALL BE DEBATED PER TABLE 310-15(B)(3)(o) OF APPLICABLE EDITION OF THE NEC. 4. CONDUIT FILL IS BASED ON CHAPTER 9, APPENDIX C OF THE NEC. WALL B STAMPS AND SEALS �zl-=mNWWDWD Ou GrI -Z DxaDO�Nw z � ozw 8a i ax� �a"BQ�WZ !- Hwya 0 aw� Ng� yZjzUQ ~ wo D-<, Z� a �j O �./ .Q zo O� 0 �co 0 U I 0 00 W c\? co 0 0 10 Z w O J (J) Z � = W aco J - p 00 Q ON H XU 2 0 U w W J W DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Na ner SERIAL NUMBER: 1603 -105 SCALE 24X36: NONE SHEET: E4 v a COIL 50' OF ALARM WIRE TO TB6 IN BYPASS (C-BLK) DSWPH03 MODULE SCALE: NONE TO TB6 IN BYPASS (NC -RED) TBI TO TERMINAL BOARD LI L2 120V SURGE PROTECTOR MODULE SCALE: NONE TO T66 IN BYPASS (C-BLK) WNITE/GREEN TO T66 IN (NC -RED) 2 a BYPASS TBI o o a 5 3 o r� UPSI 12-NC l l UPSI RUN 4 UPSI 14-C J #22 SOLID 7 GREEN/WNITE 0 0 UPSI 12-NC 1 UPSI BYPASS JUMPER s o 0 0 UPSI 17-C J #22 SOLID W41TE/BROWN 7 0 0 0 UP51 12-NC UPSI POWER FAIL 18 BROWN/WHITE EV 0 0 0 UPSI II-C #22 SOLID 1q WNITEBLUE 9 0 o p UPSI 12-NC l L UP51 FAIL 10 UP51 14-G J #22 SOLID 21 GRAY/WNITE ORANGE/WNITE 19 UPSI 12-NC UP51 LOW BATTERY p 12 UPS 17-C #22 SOLID 9 WHITE/ORANGE 0 0 BLUE/WHITE 13 0 0 0 UPSI 12-NC UP51 SUMMARY 6 WNITE/GRAY 14 UPSI ll-C #22 SOLID UPS1 ALARM CONNECTIONS SCALE: NONE NOTE: I. LEIBERT 20kVA UPS 25-PIN INTERFACE CABLE CONNECTION DAI DOOR ra� ''�ALARM HTA HIGH TEMP ALARM SERI ES ALARM LOW TEMP ALARM 150I4 LOW ° HUMIDITY ALARM NIGH ° HUMIDITY ALARM DI SMOKE [ q-- I ALARM MISC. DIAGRAMS SCALE: NONE ALARM UP52 12-NC } UPS2 RUN UP52 14-C #22 SOLID UPS2 12-NC l LUPS2 BYPASS UP52 17-C J #22 SOLID UP52 12-NC UPS2 POKER FAIL UPS2 Il-C J SOLID UP52 12-NC l#22 L UP52 FAIL UP52 14-C J #22 50LID UPS2 12-NC UP52 LOW BATTERY UPS2 17-C #22 SOLID UP52 12-NC UPS2 SUMMARY UPS II-C #22 SOLID UPS2 ALARM_CON_NEC_TIONS SCALE: NONE NOTE: I. LEIBERT 20kVA UPS 25-PIN INTERFACE CABLE CONNECTION LAI PRIMARY SECONDARY SUPPRS50R SUPPRESSOR C NO NC C NO NC u C NC NOT USED NOT USED LA2 PRIMARY SECONDARY SUPPRESOR SUPPRESSOR C NO NC C NO NC u C NC NOT USED NOT USED ONE -LINE WIRING DIAGRAM SCALE: NONE NO -L -BLACK C WHITE USE 3/22 AWG SOLID WIRE NC RED (NON-SHEILDED) ALARM WIRE COLOR CODE SCALE: NONE SWITCH CIRCUIT \_�� BREACKER ff PHOTO CELL LIGHT EXTERIOR LIGHT CIRCUIT SCALE: NONE CIRCUIT BREAKER POWER FAIL ALARM POWER FAIL DIAGRAM SCALE: NONE HVAG-1 FAIL HVAC-2 FAIL ALARM ALARM NC NC 0 0 c c HVAC_FA_I_L DIAGRAM SCALE. NONE STAMPS AND SEALS Q �NOul z Zi 1-taW W =a�ZE 4 o J ui In /Q NV V W J W DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Na ner SERIAL NUMBER: 1603-105 SCALE 24X3G: NONE SHEET: E5 3/81, " TOP VIEW C� REAR VIEW 3/4" DIAMETER m 5 n 3/4"-10 FERRULE (2) PLACES EACH (2) PER FERRULE, MIN. INTERIOR LIFT DEVICE 3 1/2" HOLD 3/4" DIAMETER (TYP) SIDE VIEW LIFT DEVICE NOTES: I. FLOOR AREA < 240 50. FT. 4 INTERIOR LIFT DEVICE PER FLOOR 2. FLOOR AREA > 240 50. FT, 8 INTERIOR LIFT DEVICE PER LOAD INTERIOR LIFT -DEVICE SCALE: 1-1/2" = 1'-0" FLOOR LAYOUT SCALE: INTERIOR LIFT DEVICE SEE DETAIL THIS SHEET #4 BAR GR. 60 3 SIDES #4 GR. 60 HOOK BAR 3/16" A ° T ° 4 " ° m � ;::::ri - % 1/2" x 5/16" STEEL ANGLE m SIDE VIEW TOP VIEW FLOOR INTERIOR LIFT DEVICE DETAIL SCALE: 1-1/2" = 1'-0" #4 GR 60 REBAR WITHIN I" OF TOP SURFACE OF FLOOR SEE INTERIOR LIFT DEVICE DETAIL PERIMETER ANGLE DOOR EMBED PLATE (TYP) DETAIL FOR DOOR LOCATION SCALE: 1-1/2" = 1'-0" THIS DETAIL APPLIES ONLY WHEN LIFT POINT 15 UNDER DOOR OPENING `NTERIOR LIFT DEVICE SEE DETAIL THIS SHEET / �3" MIN RADIUS 4 DO NOT SPLICE WITHIN 24" EA. SIDE OF LIFT DEVICE E a OVERLAP 36" MIN. n MID FLOOR CROSS TIE SCALE: NONE INTERIOR LIFT DEVICE SEE DETAIL THIS SHEET 3" MIN RADIUS OVERLAP 36" MIN. END FLOOR CROSS TIE 5 SCALE NONE ONE PER LIFT DEVICE PAIR REBAR: #4 GR 60. 3AR AT JRS #4 60 GkAur KCDAK A I i= v- . TYPICAL FLOOR REBAR LAYOUT SCALE; NONE REBAR NOTES: SHORT (TENSION) DIRECTION I" FROM BOTTOM OF CASTING BED • LONG (TENSION) DIRECTION 1-3/4" OR JUST ABOVE TENSION REBAR CASTING DETAIL NOTES: REINFORCING BAR: • REINFORCING BAR TO BE ASTM A615, LATEST REVISION, PLAIN BILLET STEEL • REINFORCING BAR GRADE 60 OR HIGHER IS NOT PERMITTED FOR EMBED PLATE EXTENSIONS. • REINFORCING BAR FOR SLAB STRENGTH AND T*S TO BE ASTM A615 GRADE 60. • LIGHT RUST ACCEPTABLE PER ASTM A615, SECTION 12, SCALING AND PITTING NOT PERMITTED. • REINFORCING BAR BEND RADII SHALL NOT BE LE55 THAN SIX BAR DIAMETERS. • LOCATION AND FORMING TOLERANCES: +/- 1/8" • MAXIMUM CONCRETE COVER BETWEEN CASTING BED AND PRIMARY SLAB STRENGTH REINFORCING BAR SHALL NOT EXCEED V. • TRANSVERSE REINFORCING BARS (PRIMARY STRUCTURAL REBAR) SHALL NOT BE SPLICED. • LONGITUDINAL REINFORCING BARS (Tt5 REBAR) MAY BE SPLICED - AT MOST EVERY 48" WITH A MINIMUM OVERLAP OF 18" WELDING: • WELDING PRACTICE FOR REINFORCING BAR TO CONFORM TO AWS DIA, LATEST EDITION • WELDING PRACTICE FOR STRUCTURAL STEEL TO CONFORM TO AWS DI.1, LATEST EDITION • DO NOT WELD REINFORCING BAR WITHIN THREE BAR DIAMETERS OF A BEND. • DO NOT WELD GRADE 60 REINFORCING BAR. • GRADE 40 REINFORCING BAR REQUIRED TO BE WIRE TIED CONNECTIONS ONLY. • CONTINUOUS ELECTRODES TO CONFORM TO AW5 A5.15 OR AW5 A5.20, LATEST EDITION. • OTHER ELECTRODES TO CONFORM TO APPLICABLE AW5 STANDARDS. OTHER MATERIALS • PLATE AND ANGLE TO BE ASTM A36 Fy = 36 KSI (MIN) • HEADED STUDS TO CONFORM TO ASTM AI08 AND AWS D1J. HIGH STRENGTH STEEL 15 NOT PERMITTED. • HOLES MUST BE DRILLED AND REAMED OR PUNCHED. PLASMA CUTTING OR TORCHING IS NOT PERMITTED. • FLOOR -WALL CONNECTION PLATES ARE NOT TO BE SPACED MORE THAN 3' APART. • WELD PLATE HP-11 MAXIMUM SPACING 3'-0" ON LONG WALLS. CASTING LEGEND LIFTING FERRULE WELD CLIP FLOOR WELD CLIP 0 STANDARD WELD CLIP ® EXTERIOR LIFTING DEVICE • ROOF LIFTING PIN CASTING TOLERANCES WALL PANELS (SEE NOTE I) TOLERANCE FLOOR PANELS TOLERANCES LENGTH +/- 1/8 LEVEL +/- 1/8" WIDTH +/- I/8 SQUARE +/- 1/8" DEPTH +/- 1/8 VERTICAL WARP +/- 1/8" EDGE SWEEP +/- 3/8" EMBED PLATE POSITION +/- 1/4 EMBED PLATE TIP/FLUSH +/- 1/8 PENETRATION LOCATION (SEE NOTE 3) I/8 BOWING +/- 1/4 WARPING +/- 114 IN 10' LEAST DIMENSION, MAX. SQUARE (SEE NOTE 2) +/- 1/8 NOTES: I. MAXIMUM DEVIATION OVER PANEL 2. MAXIMUM DIFFERENCE IN DIAGONAL DIMENSIONS 3. UNLESS NOTED OTHERWISE STAMPS AND SEALS ww Z _ aQa�mw�Q Q �r -I! aQ wz��oat Z���p��� No—Nf-Z �zm on o�u Q §u - z F- a A` \�' N O Lo d0 O zo &� co ®w 0 O) Lo Lo cq 41 1 O co 0 O O W c co co W v, LITJ F- Q 'i'^^ v♦ J Q ® ® ♦ ,V O CV p X ® O co LL 1 f DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY J. Na ner SERIAL NUrIBER: 1603-105 SCALE ' 24X36: NONE SHEET: si 4 W WALL A LAYOUT SCALE: 3/8"=1'-0" WALL C LAYOUT SCALE: 2'-7° v I, 1'-2 c m v (4) 1 1/2" PVC 2X4 BLOCKOUT r , c P r , PVC 1'-4" 3'-0" TYP 2'-6 I/4" � SIESMIC PLATE 5 _10 SEE STUD TABLE THIS PAGE WALL B LAYOUT SCALE: 4'-0" TYP v 11- WALL D LAYOUT SCALE: :SMIC PLATE E STUD TABLE IS PAGE CASTING LEGEND LIFTING FERRULE WELD CLIP FLOOR WELD CLIP [] STANDARD WELD CLIP ® EXTERIOR LIFTING DEVICE • ROOF LIFTING PIN STUD TABLE SHELTER SHELTER WIDTH (FEET) LENGTH (FEET) 8' 10' 12' 13' 14' NUMBER OF STUDS 8' 6 6 5 5 5 9' 7 6 6 6 5 10, 7 7 6 6 6 11' 8 7 6 6 6 12' 8 7 7 7 6 13' q 8 7 7 7 14' 9 8 a 7 7 15' 10 q 8 8 7 16' 10 q 8 8 8 17' 11 q q 8 8 18, 11 10 9 q q 19, II 10 q q 9 20' 12 11 10 q q 21' 12 11 10 10 10 22' 13 II 1 II 10 10 23' 13 12 1 II II 10 24' 14 12 1 11 II II 25' 14 13 12 11 II 26' 15 13 12 12 11 27' 15 14 12 12 12 28' 16 14 13 12 12 29' 16 14 13 13 12 30' 17 15 14 13 13 31' 17 15 14 13 1 13 32' IS 16 14 14 13 33' 18 16 15 14 14 34' 19 16 15 14 14 36' Iq 17 15 15 14 36' 20 17 16 15 15 37' 20 18 6 16 15 38' 21 18 16 16 15 39' 21 IS 1 17 16 16 40' 21 Iq 1 17 17 16 EXTERIOR FINISH SCHEDULE ITEM SURFACE FINISH PAINT COLOR ROOF TROWELED SMOOTH SEALED, ELASTOMERIC COURSE PAINT TELECOM BROWN WALLS EXPOSED WASHED AGGREGATE OKITE STAIN (2 COATS) - DOORS STEEL, RATED PAINT TELECOM BROWN JOINTS AS FINISHED SEALED PER 'DETAILS SHEET TELECOM BROWN CASTING TOLERANCES WALL PANELS (SEE NOTE 1) TOLERANCE FLOOR PANELS TOLERANCES LENGTH +/- 1/8 LEVEL WIDTH +/- 1/8 SQUARE DEPTH +/- 1/8 VERTICAL WARP EDGE SWEEP EMBED PLATE POSITION +/- 1/4 EMBED PLATE TIP/FLUSH +/- 1/8 PENETRATION LOCATION (SEE NOTE 3) +/- 1/8 BOWING +/- 1/4 WARPING +/- 1/4 IN 10' LEAST DIMENSION, MAX. SQUARE (SEE NOTE 2) +/- 1/8 NOTES: 1. MAXIMUM DEVIATION OVER PANEL 2. MAXIMUM DIFFERENCE IN DIAGONAL DIMENSIONS 3. UNLESS NOTED OTHERWISE STAMPS AND SEALS AAmmank Lo Lb 0 rVr1 .Q zo cd O j p ~� c OwLO O � �cli +� I A co 0 cv d U I 00 W GmGo w w co pA w z Z cl) � Q o® v ® N J Q ® � b r r DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Wagner SERIAL NUMBER: 1603-105 SCALE 24X36: NONE SHEET: S 2 a