HomeMy WebLinkAboutBUILDING PLANSI
o
MARTIN COUNTY, FL
11'-8" X 24'=O" SHELTER
M
t«'>1
EME
NOSMOI MG
o a o 0 0 0 0 0
Building Notes:
These plans comply w/ Rule 6TG20-3.006 for product
approval
The sealed set of plans are on file in the third
party agency's office as directed by the DBPR
This building has NOT been designed or approved for
placement in High Velocity Hurricane Zones (HVHZ)
This building is subject to review and approval of
the fire inspector on site w/ compliance w/ Ch, 633
Fire Safety Code
The manufacturer's data sheet and the state (DBPR)
nsigria shall be permanently mounted to or about
the electrical panel
This structure has been designed for erection or
installation on a site built permanent foundation and
is not designed to be moved once erected or
installed
Light Frame Construction Identification Placards (on
site or details provided)
SPECIAL CONDITIONS / LIMITATIONS
I. SEPARATION FROM EXISTING STRUCTURES TO BE 10' OR GREATER.
2. THI5 STRUCTURE 15 NOT DESIGNED FOR INSTALLATION IN A
FLOOD HAZARD AREA.
3. THIS STRUCTURE 15 NOT DESIGNED FOR HUMAN OCCUPANCY
EXCEPT FOR SHORT TIME PERIODS FOR EQUIPMENT MAINTENANCE.
4. THERMOBOND WILL NOT BE RESPONSIBLE FOR INSTALLATION OF
ANY SPRINKLER SYSTEM, WHICH MAY BE REQUIRED BY LOCAL
BUILDING OFFICIAL.
S. THERMOBOND WILL NOT BE RESPONSIBLE FOR ANY ANTENNA
INSTALLATION ASSOCIATED WITH THIS BUILDING.
6. THIS BUILDING SHALL NOT BE LOCATED AT A SITE THAT EXCEEDS
THE LISTED DESIGN LOADS.
7. IF BATTERIES W/ AN ELECTROLYTE CAPACITY OF MORE THAN 50
GAL. ARE TO BE INSTALLED IN THIS BUILDING, ONE OF THE
FOLLOWING MUST BE INSTALLED BY OTHERS ON SITE:
a. AN EXHAUST FAN W/ A HYDROGEN LIMIT SWITCH TO LIMIT THE
HYDROGEN TO 1% OF THE TOTAL VOLUME OF THE ROOM.
b. CONTINUOUS VENTILATION SHALL BE PROVIDED AT A RATE NOT
LE55 THAN I CU.FT. PER MINUTE PER 50.FT. OF FLOOR AREA
OF THE ROOM.
8. THI5 BUILDING IS NOT INTENDED FOR OCCUPANCY. THE LIGHTING
SHOWN IS REQUIRED FOR A SERVICE TECHNICIAN TO FUNCTION
SAFELY.
DESIGN LOADS
OCCUPANCY TYPE (RISK CAT.): IV
FLOOR LIVE LOAD: 300 psF
ROOF DESIGN LOAD (STRENGTH): 150 psf
ROOF DESIGN LOAD (DEFLECTION): 75 psf
Pf - (0.7) * (Ce) * (1) * (Ct) * (Pg)
WIND DESIGN
WIND SPEED: 168 Vult (ASCE 7-10)
EXPOSURE: D
Iw=1.15 a=3Ft
GCpi = t 0.18 (PER ASCE 7)
ENCLOSED BUILDING INTERNAL PRESSURE
EXPOSURE FACTOR Ce 1.0 ZONE 1: P= 24.20 PSF P= 5q.50 PSF
IMPORTANCE FACTOR Is = 1.15 ZONE 2 P= 24.20 PSF P= 9q.90 PSF
THERMAL FACTOR Ct = 1.0 ZONE 3: P= 24.20 PSF P= - 150.30 PSF
GROUND SNOW LOAD Pg 60 ZONE 4: P= 54.50 PSF P= 5q.50 P5F
ZONE 5: P= 54.50 PSF P= 6q.60 P5F
ITEMS TO BE INSTALLED ON SITE AND ARE SUBJECT LOCAL
INSPECTION ;
1, Installation of foundation Tie Down Plates,
2, Installation of door canopy.
3. Installation of 70kw generator,
SHIPPING
INFORMATION:
SEISMIC DESIGN:
COPY
BUILDING DEAD LOAD: 72,000 LBS
SHIPPING HEIGHT: 10'-5 1/8" BUILDING FOOT PRINT: 280 50. FT.
SHIPPING WIDTH: 11'-8" SEISMIC DESIGN CATEGORY: D
SHIPPING LENGTH: 24-0" BA51C SEISMIC -FORCE -RESISTING SYSTEM: INTERMEDIATE PRE -CAST WALL
SHIPPING WEIGHT: 72,000 LBS ANALYSIS PROCEDURE: ELF
ASSUMED SITE CLASS: D
DESIGN SPECTRAL RESPONSE ACCELERATION: 55 1.50 51 = 0.10
SITE COEFFICIENTS: FA = 1.00 FV = 2.2
DESIGN BASE SHEAR: V = CSW = (0.375) (72,000% = 27000 LBS
W - ESTIMATED WEIGHT WITH EQUIPMENT
le - 15
SCA1>nNE-4
13Y
St Lucie County
sgezk)2
St LUCIE
PLAN R
DATE:
DATE:
PLUMB: _
DATE:
MECH:
DATE
DRAWING INDEX
SHEET DESCRIPTION
REV
12
REV VREV REV
5
REV
6
Cl COVER SHEET
C2 MATERIALS L15T
Al FLOOR PLAN
A2 ELEVATIONS
A3 FOUNDATION
El ELECTRICAL SCHEMATIC
ELI ELECTRICAL PANELS
E1.2 ALARM DIAGRAM
E2 GROUNDING LAYOUT
E2.1 GROUNDING DETAILS
E3 WIRE MOLD
E4 ELECTRICAL DIMENSIONS
E5 ELECTRICAL DETAILS
51 FLOOR CASTINGS
52 WALL CASTINGS
52.1 WALL CASTINGS DETAILS
53 ROOF CASTINGS
54 GRO55 SECTION
T1 TRANSPORT CONNECTIONS
T2 INSTALL DETAILS
RELEASE DATES
STATUS RELEASED TO BY DATE
P=PROGRESS F=FINAL R=REVISED PR=PRODUCTION C=CUSTOMER 5=STATE/THIRD PARTY
REVISIONS
REV DESCRIPTION BY DATE
I
2
3
4
5
6
7
FLORIDA
OCCUPANT LOAD: I
CONSTRUCTION TYPE: 56
USE GROUP: 52
CODES:
2011 NATIONAL ELECTRIC CODE
2014 FLORIDA STATE BUILDING CODE -BUILDING
2014 FLORIDA STATE BUILDING CODE -MECHANICAL
2014 FLORIDA STATE BUILDING CODE -ENERGY
EXEMPT FROM FLORIDA ENERGY CODE PER. SEC. 101.4.8.5
FOR EQUIPMENT SHELTERS)
I FT ° 439 - Model AGE3959G
e sues i
dp
FL OW ...9.+m.
STAMPS AND SEALS
Ja WttM^z
za wZ p pi
j 0O N
ut~
ZZappu
of
W
in ^
V/ W
2_
J LL
s
o
O
p N C)
O
2 60
r
40
J
LL
Ln
Alma
9+
O
V im
LLI
QL
z z
w
z
ry
a a
DATE:
3/8/16
SALES MANAGER:
D. Brunswick
DRAWN BY:
J. Na ner
SERIAL NUMBER:
1603-105
SCALE 24X36:
NONE
SHEET:
C 1
IL
MATERIALS LIST
ITEM QTY UM DESCRIPTION MANUFACTURER MFR PART NUMBER TBB PART NUMBER NOTE
i EA 300A PANELBOARD INTERIOR SQUARE D N0421-2C 200-0276 8,12
1 1 EA 300A PANELBOARD MCB KIT SQUARE D NQM54LA 200-0467 8
1 EA MAIN CKT BKR, 2/300A SQUARE D LAL26300 200-0598 8
1 EA 300A PANELBOARD BOX SQUARE D MH62 200-0464 B
2
1 EA 300A PANELBOARD COVER SQUARE D NC62S 200-0465 8
3 2 EA IGROUND BAR SQUARE D PK15GTA 700-0022 6
4 1 EA CKT BKR, 2/15A SQUARE D 00216 200-0023 8
5 2 EA CKT BKR, 1/15A SQUARE D Q0115 200-0051 8
6 2 EA CKT BKR, I/BOA SQUARE D 00130 200-0054 8
7 2 EA CKT BKR, 2/50A SQUARE D 50 200-0065 8
8 I EA CKT BKR, 2/60A SQUARE D 00260 200-0066 8
q 2 EA CKT BKR, 2/125A SQUARE D Q02125 200-0070 8
10 106 EA JCKT BKR, 1/20A SQUARE D 00120 200-0052 8
11 2 EA 200A SUB -PANEL, 1/3W SQUARE D 0014ON200 200-0152 8
12 2 EA SUB -PANEL COVER SQUARE D QOC40US 200-0164 8
13 4 EA GROUND BAR SQUARE D PKI8GTA 700-0022 6
14 4 EA GROUND BAR ISOLATOR KIT SQUARE D PKGTAB 200-01g7 8
15 1 EA CKT BKR ENCLOSURE, 400A WITH NEUTRAL KIT SQUARE D LA40OS/4005N 200-0601 200-0346 8,12
I6 I EA CKT BKR, 2/300A SQUARE D 04L2300 200-0602 8
17 1 EA CKT BKR ENCLOSURE, 100A SQUARE D 00210OBNS 200-01% 8112
IS 1 EA JCKT BKR, 2/60A SQUARE D 00260 200-0066 6
Ig 1 EA SURGE ARRESTOR, TYPE 2 - MOV, 120/2401 1/3W TRAN5TECTOR DSAPEXIMAX608MM 100-0065 8,12
20 1 EA SURGE ARRESTOR, TYPE 1 - SAD/MOV, 120/240, Io/3W TRANSTECTOR DSAPEXIMAX808 100-0087 8112
21 4 EA SURGE PROTECTION, 120V MODULE TRANSTECTOR 12R-ICP120V 100-0181 8
22 5 EA SURGE PROTECTION, 13V MODULE TRANSTECTOR D5WPHO3 101-0526 B,12
23 1 EA ENCLOSURE, 3R, 6 X 6 X 4 HOFFMAN A6R64NK 300-0172 7
24 3 EA ENCLOSURE, NI, 6 X 6 X 4 HOFFMAN ASEGX6XANK BOO-0173 7
25 2 EA ENCLOSURE, NI, 12 X 12 X 6 HOFFMAN ASE12X12XGNK 300-0174 7
26 2 EA INEAT14ERPROOF GFCI RECEPTACLE PASS 4 SEYMOUR 2095TRWRl 800-0034 8
27 8 EA IDUPLEX RECEPTACLE LEVITON CR20-1 800-0031 7112
28 3 EA SINGLE POLE SWITCH LEVITON C5120-21 BOO-0058 7
2q 8 EA 48" 32H 2-BULB FLUORESCENT LITHONIA 58 2 32 120 RE BDP 500-Olg2 7
30
31 1 EA EMERGENCY/EXIT LIGHT LITHONIA LHQM 5 W 3 R 600-0019 7
32 I EA LED EXTERIOR LIGHT W/PHOTOCELL LITHONIA OLW14 500-0040 2,7
33 2 EA 48,000 BTU HVAG W/5KW HEAT MARVAIR AVPA46ACA05ON Sqq-035q 8
34 2 EA SUPPLY GRILL MARVAIR 80676 S99-0026 8
35 2 EA RETURN GRILL MARVAIR 80679 899-002q 8
36 1 EA LEADLAG MARVAIR COMMSTAT 3 100-0030 8,12
37
38 1 EA ENTRY PORT, 4 X 3 MICROFLECT B1334 Iqq-0085 8
3q 1 EA GROUND BAR KIT HARDER EPK12MOT 200-0116 8
40 3 EA 66 BLOCK W/AMPNENOL CONNECTOR SIEMON 566M12-5W 050-0022 7112
41 3 EA AMPHENOL CABLE ORTRONICS OR-804025PCO50-IGY 752-0080 7
42 150 EA BRIDGE CLIP SIEMON SAl-55-100 050-0004 7
43 1 EA DOOR ALARM SENTROL 1047T 500-0106 7,12
44 1 EA 3070 DOOR, RP OUTSWING (FL4553) CECODOOR 0q8-1120 d 0%-0120 4
45 1 EA IDEADBOLT COMPASS Oq8-2230 7
46 1 EA ICORE, 7-PIN, A -TYPE CENTRAL IN HARDWARE 003-1012 7
47 1 EA PA55AGE LEVER SET COMPASS 0%-2110 7
48 I EA NRP-SS HINGES, SET OF 3 SOMMER B55000-N-652 OqB-3110 7
4q I EA MAGNETIC WEATHER STRIPPING (3070) PEMKO 2815 OqB-3210 7
50 1 EA 36" THRESHOLD REESE 5205 Oq8-3310 7
51 1 EA 36" NEOPRENE STYLE DOOR SWEEP REESE 323C OqB-3410 7
52 1 EA ANTI -PICK PLATE LATCH GUARD LGIOOZ/SF Oq8-3650 7
53 1 EA 36" THRESHOLD STOP REESE 095-3311 7
54 1 EA 40" DRIP CAP COMPASS Oq8-3610 7
55 I EA HYDRAULIC DOOR CLOSER WITH HOLD OPEN ADVANTAGE 8001 Oq8-3522 7
56 1 EA 13070 DOOR CANOPY B*T OqB-3660 2,4
57 1 EA IOLB CO2 FIRE EXTINGUISHER KIDDE PROIOCDM 3qq-0051 2,7
56 1 EA 120LB DRY CHEM FIRE EXTINGUISHER KIDDE PP020TCM Sq9-0067 2,7
5q I EA METAL WALL POCKET SAFCO 21DIgq 001-2048 7
60 1 EA EYE WASH HONEYWELL GRAINGER# 3ARD6 3q9-0255 7
61 1 EA FIRST AID KIT NORTH GRAINGER# 4EYg2 3qq-0254 7
62 1 EA NO SMOKING SIGN BRADY GRAINGER# 4T676 3qq-0108 7
63 1 EA ELECTRO EMISSION SIGN RICHARD TELL ASSOCIATES TE55CQ# 2037q 3qq-0109 7
64 1 EA TELCO BOARD, 3' X 4' X 3/4", GRAY THFRM050ND 753-2191
65 1 EA POWER FAIL RELAY W/BASE DAYTON GRAINGER# 3X740/5X852 100-0034 fi 100-0001 7,12
66 50 FT 24" CABLE LADDER W/HARDWARE CENTRAL STEEL FABRICATORS 10024 001-2231 7113
67 10 FT 6" CABLE LADDER W/HARDWARE CENTRAL STEEL FABRICATORS 10006 001-2232 7113
68 1 EA JAASTE BASKET TOUGH GUY GRAINGER# 4PGN2 3qq-Olgq 117
6q I EA IDUST PAN TOUGH GUY GRAINGER# IVAJ7 3qq-0054 117
70 1 EA BROOM TOUGH GUY GRAINGER# IVAC2 101-0301 1,7
71 1 EA UTILITY HOLDER BATTALION GRAINGER# 4466 101-0528 7
72 1 EA 4" WIREWAY, IOFT B-LINE 44120 G NK 300-0037 7
73 2 EA 4" WIREWAY, 4FT B-LINE 4448 G NK 300-0039 7
74 I EA 4" WIREWAY, 3FT B-LINE 4436 G NK BW-0107 7
75 2 EA 4" WIREWAY END CAP B-LINE 44 E NK 300-0028 7
76 1 4 1 EA 4" WIREWAY CONNECTER B-LINE 44 C. 300-0049 7
77 0.1 1 EA JIOFT WIREMOLD WIREMOLD ALA480OB-10 001-2327 8
78 3 EA 18FT WIREMOLD WIREMOLD ALA480OB-8 001-2327 8
WIREMOLD END CAP WIREMOLD ALA45106 001-2340 8
W1REMOLD BLANK COVER WIREMOLD ALA-BL 001-232q 6
WIREMOLD 4 HOLE COVER WIREMOLD ALA-BL (SEE E3) 001-232q 8fffO0WIREMOLD2HOLECOVERW1REMOLDALA-BL (SEE E3) 001-232q 8
WIREMOLD RECEPTACLE PASS $ SEYMOUR 5358 800-0105 7,12
20 KVA UPS LIEBERT A54DONCYHNN8
50-I115UPSBYPASSSWITCHILIEBERTNMBHW81/202816GI 8,12
MATERIALS LIST
ITEM QTY UM DESCRIPTION MANUFACTURER MFR PART NUMBER TBB PART NUMBER NOTE
86 1 EA 70 KW GENERATOR GENERAC LPV700D 025-0321 6,1
87 1 EA 300A ATS, I0/3W, 240V GENERAC GTS STYLE 025-02% E 025-02% 8,12
88 1 EA SMOKE DETECTOR WITH AUXILIARY RELAY BRK 7010/RM4 100-0185 # 100-0184 7
Bq 2 EA 125A SUB -PANEL, 10/3W SQUARE D Q0124MI25 200-0149 8
qO 2 EA SUB -PANEL COVER SQUARE D QOC24US 200-0161 8
ql 2 EA GROUND BAR SQUARE D PKI5GTA 700-00lq 8
112 2 EA GROUND BAR ISOLATOR SQUARE D PKGTAB 200-01C17 8
93 1 EA BAIT WIRE SYSTEM HARDER MOTOGBALARMKT 001-2257 8
q4
q5
96
q7
98
qq
100
101
102
103
104
105
lob
107 3 EA GROUND STRAP BARS
108 3 EA GROUND STRAP COVERS 650-0048 I
IOq 60 EA RIVETS
110 4 EA LIFTING LUGS 1
111 4 EA TIE DOWN PLATES
112 8 EA TIE DOWN BOLTS
113 B EA BLACK PLASTIC BASE PLUGS
114 10 EA FLOOR TILES I
115 1 1 1 EA ITUBE OF BRILLIANT WHITE CAULK 1
116 4 EA TUBES OF BEIGE DYMONIC CAULK 1
117 1 EA PINT CAN OF TELECOM BROWN PAINT 1
118 1 EA PINT CAN OF ELASTOMERIC COURSE PAINT 1
Ilq 25 EA 1/8" SHIMS FOR SHELTER SET
120 25 EA 1/4" SHIMS FOR 514ELTER SET
MATERIAL LIST NOTES:
I, SHIP LOOSE
2. PREINSTALL REMOVE FOR SHIPMENT
3. FABRICATED ITEM
4. PAINT - TELECOM BROWN
5. PAINT - TELECOM GRAY
6. PAINT - COLOR DESIGNATED
7. OR EQUIVALENT
8. NO SUBSTITUTIONS ALLOWED
q. NO PART NUMBER SPECIFIED
10. MAY BE DELIVERED AT SIGHT
11. PROVIDED BY OTHERS
12. LABEL
13. QUANTITY ESTIMATED
STAMPS AND SEALS
No
TwSCa( -
Q Q pu
Q
Za
wZ o o
c QCie ao g J
IN F-
nc w
W
uj
A
Q
V/ V/ o
J
Q
A
prli.
ON
W F-
X a G
r
r
C
w
m z
z4
kiw0..
a DATE:
3/
8/16 SALES
MANAGER: D.
Brunswick DRAWN
BY: J.
Na ner SERIAL
NUMBER: 1(
003 -105 SCALE
24X36: NONE
SKEET:
C
2
00
9'-1 3/4"
WALL D
4'-2" MAX.
20
22
EXT
EXT
66
ff------ in
88
ROW 3
WALL C
24' -0"
78 79 80 81 83 29
ROW 2 ROW 1
m
L,J Ilfil
ISO
IIII
NMI
Elio'
lilll__II I
III
I IIIIII('=
IIIIIIII!
IIIIIIII
I•III I 11 IllllrjII!I r
IIII I
IIII I(
IIII
lllllll
IIIIIIII
WALL A
FLOOR PLAN
SCALE I/2"=1'-0"
COMMERCIAL POWER:
120/240VAC, 300AMP SINGLE PHASE SERVICE,
CONDUIT RUNS:
I. ALL CONDUIT RUNS TO BE EMT UNLESS STATED OTHERWISE.
2. ALL CONDUIT RUNS TERMINATING AT SERVICE ENTRANCE EQUIPMENT SHALL CONTAIN BONDED
BUSHINGS.
3, WIREWAYS CARRYING 3 OR MORE CURRENT CARRYING CONDUCTORS SHALL BE DERATED PER
TABLE 310-15(5)(3)(o) OF APPLICABLE EDITION OF THE NEC.
4. CONDUIT FILL IS BASED ON CHAPTER 9, APPENDIX C OF THE NEC.
CABLE LADDER:
I. CABLE LADDER IS TO BE 8'-0" A.F.F. AND INSTALLED IN ACCORDANCE WITH ARTICLE 392
OF THE NEC LEVEL TO WITHIN 1/8" IN 10' OR SIMILAR.
GROUNDING:
I. ALL GROUNDING EXCEPT FOR CABLE LADDER TO CONFORM TO ARTICLE 250 OF THE NEC.
2. CABLE LADDER GROUNDING TO CONFORM TO ARTICLE 392.60 OF THE NEC,
GENERAL NOTES:
I. LABEL FACE OF ALL ELECTRICAL EQUIPMENT WITH PHENOLIC LABELS. BLACK WITH WHITE
LETTERS. EXTERNAL BYPASS, TI, SDI, $ LAI. EXCEPTION SHALL BE ALL UPS EQUIPMENT SHALL
HAVE PHENOLIC LABELS RED WITH WHITE LETTERS. EX UPSITPI, UPSI, WIREMOLD RECEPTACLES.
2. CONNECT ALARMS TO UPS WITH A DB25 PIN CONNECTOR.
3, CONNECT CIRCUITS PPI-22 $ PPI-24 TO THE EXTERIOR SURGE PROTECTOR AND LABEL.
4. COIL AND TAG 50' OF ALARM WIRE FOR GENERATOR ALARMS.
S. CONNECT GENERATOR ALARMS TO THE DSWP03 SURGE PROTECTION MODULES.
6. COIL AND TAG 12" OF #10 WIRE FOR CIRCUITS, PPI-2 $ 4.
7. COIL 12" OF ALARM WIRE FOR TOWER LIGHT ALARM. TBI-25 $ 26.
8. COIL 50' OF #18 AWG FOR GENERATOR CONTROL WIRE.
M
WALL B
STAMPS AND SEALS
4=mw zz d
a ZQ0rzw3.i i
a
LO
c
i co
0
IUD
co
oNd
v I
O
O O
W CDOLO A
O
w
J
Q
Q cf) J
J_ a
O CDW
qqT
ON O
X J
O_ LL
r
r
DATE:
3/8/16
SALES MANAGER:
D. Brunswick
DRAWN BY:
J. Wagner
SERIAL NUMBER:
1603-105
SCALE " 2AX36:
NONE
SHEET:
Al
2" OVERHANG
TYP
TEME
NOSN01(ING
q.
I Po o Q Q Q
4'-5 7/8" 3'-4 1/4"
24-0" (TYP)
o" TYP T-8"
FRONT ELEVATION (WALL A)
SCALE: NONE
REAR ELEVATION (WALL C)
5C41-E: NONE
11 O I/All
I" NIPPLE FOR TOWER
LIGHT ALARM
I" NIPPLE FOR TOWER
LIGHT ALARM
I" PVC FOR
BAIT WIRE
2) 3" PVC FOR
TELCO ENTRY
1" PVC AT 45'
2 MECHANICAL
LUG (2 PLACES)
Lr14Yi
L JCi.J G J
m
RVAI
L____J
I
RIGHT ELEVATION (WALL B
SCALE: NONE
LEFT ELEVATION (WALL D
SCALE: NONE
EXTERIOR FINISH SCHEDULE
ITEM SURFACE FINISH PAINT COLOR
ROOF TROWELED SMOOTH
SEALED, ELASTOMERIC COURSE TELECOM BROWN
PAINT
WALLS EXPOSED WASHED OKITE STAIN (2 COATS)
AGGREGATE
DOORS STEEL, RATED PAINT TELECOM BROWN
JOINTS AS FINISHED SEALED PER DETAILS SHEET TEL BROWN
ELEVATION NOTES:
I. SEE MATERIALS LIST FOR SHIPPED LOOSE ITEMS.
2. SEE MATERIALS LIST FOR DOOR HARDWARE.
OR GENERATOR
R GENERATOR
STAMPS AND SEALS
W Z
oN fl a d
zaEwZ
zF Of
J
LL
1
C0 m
Lu
w
Q
z z
w za
wry
IL Ll
DATE:
3/8M
SALES MANAGER:
D. Brunswick
DRAWN BY:
J. Wagner
SERIAL NUMBER:
1603-10=
SCALE " 24XBG:
NONE
SPEET:
A2
LOOSE SAND OR GRAVEL
BACKFILL NOTES: 15, 16 AND 17
SHIMS (TYP)
2) #4 REBAR AROUND
PERIMETER WALL
m
3 STIRRUP AT
IS O.G. AROUND
PERIMETER WALL
SEE NOTE: 9
BUILDING FLOOR SYSTEM
2) #4 REBAR AROUND
PERIMETER WALL
I
v'UNDISTURBED OR
COMPACTED SOIL
NOTES: 5 AND 10
3) #4 REBAR AROUND
PERIMETER WALL BASE
SECTION A -A
SCALE: NONE
TYPICAL EACH WAY SEE NOTES FOR SPECIFIC
INFORMATION ON MATERIALS AND OTHER REQUIREMENTS
3 STIRRUP AT
18" O.C. AROUND
PERIMETER WALL
3) #4 REBAR
AROUND
PERIMETER
WALL BASE
SEE NOTE:
L005E SAND OR GRAVEL
BACKFILL OPTIONAL VAPOR
BARRIER SEE NOTE: 16
6"x6" MIN. PERIMETER CHAMFER
SHIMS (TYP)
2) #4 REBAR AROUND
PERIMETER WALL
GRADE
OI III Plll.1, I.1
z
rn
m
CONCRETE SLAB
BUILDING FLOOR SYSTEM
2) #4 REBAR AROUND
PERIMETER WALL
TIE DOWN PLA1
SEE DETAIL
LI BELOW)
3 STIRRUP AT
IV' O.C. AROUND UNDISTURBED OR
PERIMETER WALL COMPACTED SOIL
SEE NOTE: 9 NOTES: 5 AND 10
3) #4 REBAR AROUND
PERIMETER WALL BASE
2
SECTION A -A (OPTIONAL)
SCALE: NONE
TYPICAL EACH WAY SEE NOTES FOR SPECIFIC
INFORMATION ON MATERIALS AND OTHER REQUIREMENTS
A
L
A
i
7
A-]
FOUNDATION PLAN
SCALE: 1 /2" =1'-0"
SHIMS TYPICAL (SEE NOTE 12)
A
WWF 6x6 W2.9 x W2.9 IN
SLAB, WHEN SLAB 15 USED
sHIMs
3 STIRRUP AT ANCHOR
18" O.C. AROUND (SUPPLIED BY
PERIMETER WALL OTHERS)
3) #4 REBAR
AROUND
PERIMETER
WALL BASE
FRONT VIEW
WALL
IFTING TEE
ASSEMBLY FLOOR
3/4" / palJ
BOLT
a b FOUNDATION
3/4" X 3 3/8"
SS ANCHOR
MINIMUM
I" CHAMFER (TYP.)
3) 1-1/8"
DIAMETER HOLES
NOTES:
1. PRIME AND PAINT THORO PRODUCTS
COCOA, OR AS OTHERWISE SPECIFIED
2. THIS PART TO BE SNIPPED LOOSE WITH
BUILDING
A
4) 3/8" X 6" X loll TIE DOWN PLATES
3
TIE DOWN DETAIL
SCALE: 1-1/2" = I'-0"
THIS DRAWING IS NOT FOR CONSTRUCTION SEE NOTE: 13
FOUNDATION NOTES:
I. ALL FOUNDATION WORK BY OTHERS AND SUBJECT TO LOCAL INSPECTION AND APPROVAL.
2. FOUNDATION SURFACE SHALL BE LEVEL TO WITHIN +/- 1/8" PER 10 LINEAL FEET IN ANY
DIRECTION.
3. FOUNDATION SHALL BE SQUARE TO WITHIN +/- 1/4"
4. BASE FOUNDATION WALL FOOTING MUST BE ESTABLISHED A MIN. OF 6" BELOW FROST LINE
AND ON UNDISTURBED SOIL,
5. SOIL BEARING CAPACITY SHALL NOT BE LESS THAN 3000 PSF.
6. CONCRETE STRENGTH SHALL NOT BE LESS THAN 3000 PSI, AS DETERMINED BY ASTM
G31,C39,072, LATEST REVISION.
7, REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, LATEST REVISION,
8. CONCRETE MIX DESIGN, BATCHING AND CONSTRUCTION PRACTICES SHALL CONFORM TO ACI 318,
ACI 305R, ACI 306.1 LATEST REVISIONS.
9. DETAILING, FABRICATION AND PLACEMENT OF REINFORCING STEEL SHALL COMPLY WITH ACI
315, ACI 3181 ACI 306R, AWSDI.4 LATEST REVISIONS, AND WITH CRSI STANDARDS,
10. COMPACTION REQUIREMENTS TO BE DETERMINED BY ENGINEERING ANALYSIS OF SITE SPECIFIC
DATA.
11. TIE DOWN PLATES, IF USED, MUST BE ENTIRELY ABOVE GRADE.
12. SHELTER MUST BE SHIMMED.
13. THIS INFORMATION IS PROVIDED FOR REFERENCE ONLY. FINAL DESIGN BASED ON SITE SPECIFIC
DATA 15 THE RESPONSIBILITY OF THE SITE CONTRACTOR,
14. PROVIDE PROPER DRAINAGE AWAY FROM FOUNDATION AT GRADE,
15. SLAB REINFORCEMENT TO BE LOCATED IN UPPER THIRD OF SLAB.
16. BACKFILL DEPTH REQUIREMENTS TO BE DETERMINED BY ENGINEERING ANALYSIS OF SITE
SPECIFIC DATA (4" MIN.).
17. BACKFILL DEPTH REQUIREMENTS TO BE DETERMINED BY ENGINEERING ANALYSIS OF SITE
SPECIFIC DATA (4" MIN.).
FOUNDATION LOADS:
2. DEAD LOAD:1375 PLF
3. LIVE LOAD: 2700 PLF
STAMPS AND SEALS
Qp[= mwW Qzz
ZsaZwZ
Lp.L Qoa-
r'Oz i3 .iYi zaQ== zaiw
oao~ r f-
a od,
NF W Ll2 mF zf
a w
W
In
J W
Q
cn J
0
O
cm
o0
r
to
44
LL
w
w
m a
z
zQwz
oQ
wr
C.
Q DATE:
3/
8/1 SALES
MANAGER: D.
Brunswic DRAWN
BY: J.
Wagnie 1603-
IC SCALE
2436: NON
SI
IEET: A3
UTILITY SERVICE WITH
GROUND 120/240 VAC
14/3W 60Hz (BY OTHERS,
SUBJECT TO LOCAL CODES)
SERVICE GROUND BONDED TO
EXTERIOR GROUND RING WHERE
ENTRY PORT 15 BONDED
120/240 vac 10/3W
60Hz 70kW
UPS GROUND CONNECTED FROM
GROUND ON UPS TERMINAL
STRIP TO MASTER GROUND BAR.
ONE -LINE WIRING DIAGRAM
SCALE NONE
NEUTRAL SHALL BE PULLED WHEN
REQUIRED BY UPS MANUFACTURER
UPS GROUND CONNECTED FROM
GROUND ON UPS TERMINAL
STRIP TO MASTER GROUND BAR.
ONE -LINE DIAGRAM NOTES:
I. ALL GROUNDING TO CONFORM TO ARTICLE 250 OF THE NEC
2. WIREWAYS CARRYING 3 OR MORE CURRENT CARRYING CONDUCTORS SHALL BE DERATED PER
TABLE 310-15(15)(3)(d) OF THE APPLICABLE EDITION OF THE NEC
3. CONDUIT FILL 15 BASED ON CHAPTER q, APPENDIX C OF THE NEC
4. INCLUDE THE NEUTRAL TO GROUND BOND SCREW TO BE DONE ON SITE BY OTHERS.
5. MINIMUM CONDUIT SIZE SHALL BE i" (TRADE SIZE 16)
SCHEMATIC LEGEND
ON SITE BY OTHERS
LUGGED LOAD CENTER ELECTRICAL EQUIPMENT
LOAD CENTER WITH
BREAKER
TRANSFER SWITCH
GENERATOR
H \ F SURGE ARRESTOR
PIG TAIL GROUND
OFF-0
BY —0 • 3 POSITION SWITCH
NOR— O
CIRCUIT BREAKER
v / F INVERTER
CONVERTER
GROUND
CONNECTION
STAMPS AND SEALS
oa w w o
7dgN o t u3pG
z aLwZpo o
t, 0 @
1—izuLu
IrmLm
Loco
Q 4
z0
Q)
04
O CA
L0
C
co
I
CCQ
0
I
O
r l c m
W .co
a
M/
NN
W H
a
W W
Q cl) VJ
O0 aN
0.
2 co V
t w
r J
w
to
J
LL
LoA
0)
MoW
LLI
Lij co
c
z
w z
Q
DATE:
3/8/16
SALES MANAGER:
D. Brunswick
DRAWN BY:
J. Na ner
SERIAL NUMBER:
1603-105
SCALE 24X36:
NONE
S{IEET:
E1
PP1 300A, 120/240VAC, 1(p/3W, 60Hz, M.BKR
LOAD VOLT AMPS WIREBREAKER BREAKER WIRE VOLT AMPS
LOADAIBIITRIPIPIIAIB
UPS) FEED
8400
1 2 125 1 2 30 1 10
3 4 30 1 10
8 2 50 5 (350 2 8
I 20 g 10
60 2 41112
13 14 15 1 1
12 1 20 15 16 20 1 12
12 2 15 17 18 20 1 12
Ig —
40
20 20 1 12
12 1 15 21 22 20 1 12
23 24 20 1 12
25 26
27 28
2g 30
31 32 1
33 34
35 36
I 2 125 37 5 40
WIRE TYPE TO BE THHN UNLESS NOTED
LOAD
OTHERS AS REQUIRED
250 TOWER LIGHT
8400 250 TOWER LIGHT
HVAC #1
3300 3300
HVAC #233003300
SPARE 60
SURGE ARRESTORBLANK60
BLANK SPARE
LIGHTS INT It EXT 1110 160 BAIT WIRE
POWER FAIL
120 1260 RECEPTACLES
120 360 RECEPTACLE GFCI
SMOKE DETECTOR 120 120 BLOCK HEATER*
BLANK 120 BATT. CHARGER*
BLANK BLANK
BLANK BLANK
BLANK BLANK
BLANK BLANK
BLANK BLANK
BLANK BLANK
UPS2 FEED
8400 BLANK
8400 BLANK
VA PER PHASE 20340 21330 4gg0 4270 VA PER PHASE
CALCULATED AT 125%
CONNECTION BY OTHERS
GROUND FAULT PROTECTION
FOR CONTINUOUS
BY
25330 25600 TOTAL VA PER PHASE
211 213 AMPS PER PHASE
50.9 TOTAL KVA
234 AMPS X 110%
UPS1TP3 125A, 120/240VAC, 1(p/3W, 60Hz, M.BKR
LOAD VOLT AMPS WIRE BREAKER BREAKER WIRE VOLT AMPS
LOADABPTRIPTRIPPAB
ROW I RECEPT #1
ROW I RECEPT #3
ROW I RECEPT #5
ROW I RECEPT #7
ROW 1 RECEPT #q
ROW I RECEPT #11
ROW I RECEPT #13
ROW 1 RECEPT #15
BLANK
BLANK
BLANK
TELCO RECEPT #1
VA PER PHASE
180
180
80
180
720 1
1
180
180
180
180
80
900 1
12
12
12
12
12
12
12
12
12
I 20 I
1 20 3
I 20 5
1 20 7
1 20 9
1 20 11
1 20 13
1 20 15
17
ig
21
I 20 23
WIRE TYPE TO BE THHN
2 20 1
4 20 1
6 20 I
8 20 1
10 20 1
12 20 1
14 20 1
16 20 1
18
20
22
24 20 1
UNLESS NOTED
12
12
12
12
12
12
12
12
12
1 180
150
150
I80
1
720
1440
12
ROW I RECEPT #2
150 ROW I RECEPT 4
ROW 1 RECEPT 6
180 ROW I RECEPT 8
ROW I RECEPT 10
160 ROW I RECEPT 12
ROW I RECEPT 14
160 ROW I RECEPT 16
BLANK
BLANK
BLANK
180 TELCO RECEPT 2
900 VA PER PHASE
1800 TOTAL VA
15 TOTAL AMPS/PHASE
3.2 TOTAL KVA
17 AMPS X 110%
UPS1TP1 200A, 120/240VAC, 1(0/3W, 60Hz, M.BKR
LOAD
VOLT AMPS I I'': BREAKER WIRE VOLT AMPS
LOADABPITRIPITRIP1PIIAB
ROW 3 RECEPT #1 180 12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
1 20 1
1 1 20 3
1 1 1 20 5
1 20 7
1 1 1 20 g
1 1 20 it
1 20 13
1 20 15
1 20 17
1 20 Ig
1 20 21
1 20 23
1 20 25
1 20 27
1 20 2q
1 20 31
33
35
37
39
WIRE TYPE TO BE THHN
2 20 1
4 20 1
6 20 1
8 20 1
10 20 1
12 20 1
14 20 1
16 20 1
18 20 1
20 20 1
22 20 1
24 20 1
26 20 1
28 20 1
30 20 1
32 20 1
34
36
38
40
UNLESS NOTED
1 12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
1 1&0 ROW 3 RECEPT 2
ROW 3 RECEPT #3 180 180 ROW 3 RECEPT 4
ROW 3 RECEPT #5 150 180 ROW 3 RECEPT 6
ROW 3 RECEPT #7 180 180 ROW 3 RECEPT 8
ROW 3 RECEPT #q 180 180 ROW 3 RECEPT 10
ROW 3 RECEPT #11 180 180 ROW 3 RECEPT 12
ROW 3 RECEPT #13 180 I80 ROW 3 RECEPT 14
ROW 3 RECEPT #15 180 180 ROW 3 RECEPT 16
ROW 2 RECEPT #17 180 160 ROW 2 RECEPT 18
ROW 2 RECEPT #19 180 180 ROW 2 RECEPT 20
ROW 2 RECEPT #21 180 180 ROW 2 RECEPT 22
ROW 2 RECEPT #23 180 180 ROW 2 RECEPT 24
ROW 2 RECEPT #25 180 180 ROW 2 RECEPT 26
ROW 2 RECEPT #27 180 1130 ROW 2 RECEPT 25
ROW 2 RECEPT #2q 180 180 ROW 2 RECEPT 30
ROW 2 RECEPT #31 180 180 ROW 2 RECEPT 32
BLANK BLANK
BLANK BLANK
BLANK BLANK
BLANK BLANK
VA PER PHASE 1 1440 1 1440 1440 VA PER PHASE
K240 2880 TOTAL VA
24 TOTAL AMPS/PHASE
5.8 TOTAL KVA
26 AMPS X 110%
UPS2TP4125A, 120/240VAC, 1(p/3W, 60Hz, M.BKR
LOAD VOLT AMPS WIREBREAKER BREAKER WIRE VOLT AMPS
LOADABPTRIPTRIPPAB
ROW I RECEPT #1
ROW 1 RECEPT #3
ROW 1 RECEPT #5
ROW I RECEPT #7
ROW I RECEPT #q
ROW 1 RECEPT #11
RQW 1 RECEPT #13
ROW 1 RECEPT #15
BLANK
BLANK
BLANK
TELCO RECEPT #3
VA PER Fi ASE
180
180
180
180
720
180
180
180
180
180
900 1
12
12
12
12
12
12
12
12
12
1 20
1 20
1 20
1 20
1 20
1 20
1 2013
i 1 20
I 20
WIRE TYPE
1
3
5
7
q
11
15
17
lg
21
23
TO BE THHN
2 20 1
4 20 1
6 20 1
8 20 1
10 20 1
12 20 1
14 20 1
16 20 1
18
20
22
24 20 1
UNLESS NOTED
12
12
12
12
12
1 12
1 12
12
12
160 ROW 1 RECEPT 2
150 ROW I RECEPT 4
180 ROW I RECEPT 6
160 ROW I RECEPT 8
180 ROW 1 RECEPT 10
180 ROW 1 RECEPT 12
150 ROW I RECEPT 14
180 RQW I RECEPT 16
BLANK
BLANK
BLANK
180 TELCO RECEPT 4
720 900 VA PER PHASE
1440 1800 TOTAL VA
12 15 TOTAL AMPS/PHASE
3.2 TOTAL KVA
17 AMPS X 110%
UPS2TP2 200A, 120/240VAC, 1(p13W, 60Hz, M.BKR
LOAD VOLT AMPS WIREBREAKER JBREAKERJNIREJVOLT AMPS
LOADABIIPTRIP1TRIP1PIAIB
ROW 3 RECEPT #I 180 12
12
12
12
12
12
12
12
12
12
12
12
12
12
1 20 1
1 20 3
1 20 5
1 20 7
1 20 g
1 20 11
1 20 13
1 20 15
1 20 17
1 20 lg
1 20 21
I 20 23
1 20 25
1 20 27
1 20 2q
1 20 31
33
35
37
3g
WIRE TYPE TO BE THHN
2 20 1
4 20 1
6 JO 1
8 20 1
10 20 1
12 20 1
14 20 1
16 20 1
18 20 1
20 20 1
22 20 1
24 20 1
26 20 1
28 20 1
30 20 1
32 20 1
34
36
Be
40
UNLESS NOTED
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
180 ROW 3 RECEPT #2
ROW 3 RECEPT #3 180 180 ROW 3 RECEPT 4
ROW 3 RECEPT #5 180 180 ROW 3 RECEPT 6
ROW 3 RECEPT #7 180 180 ROW 3 RECEPT 8
ROW 3 RECEPT #q 180 ISO ROW 3 RECEPT 10
ROW 3 RECEPT #11 180 180 ROW 3 RECEPT 12
ROW 3 RECEPT #13 180 180 ROW 3 RECEPT 14
ROW 3 RECEPT #15 150 180 ROW 3 RECEPT 1(o
ROW 2 RECEPT #17 180 180 ROW 2 RECEPT 18
ROW 2 RECEPT #19 180 180 ROW 2 RECEPT 20
ROW 2 RECEPT #21
180112
180 ROW 2 RECEPT 22
ROW 2 RECEPT #23 I80 ROW 2 RECEPT 24
ROW 2 RECEPT #25 15012 180 ROW 2 RECEPT 26
ROW 2 RECEPT #27 I80 ROW 2 RECEPT 28
ROW 2 RECEPT #29 I80 180 ROW 2 RECEPT 30
ROW 2 RECEPT #31 180 180 ROW 2 RECEPT 32
BLANK BLANK
BLANK BLANK
BLANK BLANK
BLANK BLANK
VA PER PHASE 1440 1440 1440 VA PER PHASEK242880TOTALVA
24 TOTAL AMPS/PHASE
5.8 TOTAL KVA
26 AMPS X 110Y
Arm`
I= rr-
I 'b
Loto 9
0 ...
r
z0 en
O
N
O
W to LO
co
0
cv d
U
I 0
W
o0
cv
co
0
4
X
W
V) 00
J W co
W Z 2=
a 0®
Q 0
tV 0.
t 2
J 00r
W r
CD
J
me LLn
AM
C) W m
z
z
l-Wi3d
Q Y (
Y IL
Q DATE:
3/
8/16 SALES
MANAGER: D.
Brunswick DRAWN
BY: J.
Na ner SERIAL
NUMBER: 1603-
105 SCALE
24X36: NONE
SHEET:
E1.
1
ALARM NOTES:
L ALL ALARMS TO BE NORMALLY CLOSED.
2. UNSHIELDED SINGLE TWISTED PAIR WIRE IN STANDARD.
TO TBG IN BYPASS
ALARM BLOCK #1 NC -RED)
ALARM BLOCK #2 ALARM BLOCK #3TOTBGINBYPASS
BRIDGE CLIP TYP) C-BLK)
RED 1 0 0 0 0 1 0 0 0 0
DOOR ALARM DAl-NC
2 2 GEN PRE HIGH COOLANTS( GP#CT5-NC
2 C22SOLIDDAI-C WHITE 0 o WHITE 0 0 0 o TEMP SHUTDOWN l GPNCTS-C 0 0 0 o
3 o 0 0 o RED 3 o
22 SOLID 3 0 0 0 0 C
DOOR ALARM GEN ROOM ff1 DA2-NC
4 UPS2 RUN Jr UPSI 12-NC 4 GEN LOW COOLANT 1 GLCTW-NC
22 SOLID l DA2-C 0 0 00 o 22 SOLID l UPSI 14-C WHITE o TEMP WARNING 1 GI-C
4 0 0 00 o C
5 5 22 SOLID 5REDOREDO0RED 0 0
SMOKE DETECTOR r1 DI -NC
6 UP52 BYPASS Jr UPSI 12-NC 6 E jGEN LOW COOLANT LEVEL GLTL-NC
6
tt22 SOLID l DI-C WHITE tt22 SOLID 1 UPSI 17-C WHITE O tt22 SOLID GLTL-C WHITE o 0 1
7 O o RED 7 RED 7 O 0
FIRE PANEL TROUBLE NPT-NC UP52 POWER FAIL UPSI I2-NC
6 GEN COOL TEMP FAIL GCTSF-NC
8tt22SOLIDNPT-C O 0 O O tt22 SOLID UP51 II-C WHITE tt22 SOLID GCTSF-C WHITE 0
RED 9 O RED 9 0 O RED 9 O O rL
HIGH/LOW TEMP rJ NTA-NC
10 UPS2 FAIL J UPSI 12-NC 10 GEN HIGH BATT VOLTAGE GNBVW-NC
10tt22SOLIDlPTA-C WHITE 0 0 tt22 SOLID l UPSI 14-C NHITE 22 SOLID GLBVW-G NHITE 0 0
11 0 0 o RED 11 0 O RED 11 0 0
HIGH/LOW HUMIDITY PHA -NC
12
UP52 LOW BATTERY UPSI 12-NC
12 GEN LOW BATT VOLTAGE GLBVW-NC
12
tt22 SOLID HHA-C 0 tt22 SOLID UPSI 17-C NHITE 22 SOLID GLBVW-C WHITE O O E
RED 13 0 0 RED 13 0 13 0 O [
AC POWER FAIL J PFA-NC
14 UPS2 SUMMARY UPSI 12-NC
14 GEN #
22HSOLID {
GNF-NC
14 C22SOLIDlPFA-C WHITE 22 SOLID UPSI 11-C WHITE GNF-C O O O
0 o RED 15 0 0 15 0 0 0 o C
SURGE ARRESTOR #2 J LA2-NC GEN RUN J GRN-NC
16 GEN LOW FUEL SHUT GLFS-NC
16tt22SOLID1LA2-00 o tt22 SOLID l GRN-C WHITE 0 0 tt22 SOLID GLFS-C 0 0 0 o
0 o RED 17 o a RED 17 0 0 C
VAC FAIL 1 NVAC LO-NC GEN FAIL GFL-NC
18 GEN LOW FUEL GLF-NC
18 Ctt22SOLID1NVACLO-00o tt22 SOLID GFL-C WHITE 0 0 tt22 SOLID GLF-C WHITE 0 012300oRED190019O
IST ALARM JFIRE 5YS-NC GEN DISABLE GDA-NC
20 GEN DL/##22TSOLIDO GGDLFTINC 20
22 SOLID l FIRE SYS-00 0 0 tt22 SOLID GDA-C WHITE 0 o IDI o
0 0 o 21 0 0 0 o 21 0 0 0 o
GEN ROOM IST ALARM i(FIRE SYS-NC GEN OVERSPEED GOS-NC
22 GEN DL/LP TANK 2 GDLFT2-NC
22 C22SOLIDlFIRESYS-C 0 0 0 22 SOLID GOS-G 0 0 0 0 22 SOLID GDLFT2-C 0 0 o a
0 0 0 23 0 0 0 0 23 0 0 0 o
RF LN DEHYDRATOR DENYDTR-NC 24 GEN UNDERSPEED GUS-NC
24 GEN DL/LP TANK 3 j GDLFT3-NC 24 Ctt22SOLIDSOLIDlDENYDTR-C O O O0 tt22 SOLID GUS-C 0 0 0 0 1tt22SOLIDll GDLFT3-C 0 0 0 0
RED 25 0 0 25 0 0 0 0 25 0 0 0 o C
TOWER LIGHT FAIL rJ TWR LGT-NC 26 GEN OVERCRANK J GOG-NC
26
rGENDL/LP TANK 4 J GDLFT4-NC 26 Ctt22SOLID1TWRLGT-C WHITE O O 22 SOLID l GOC-G tt22 SOLID t GDLFT4-C O O O
RED 27 00 0 00 0 7 O L_
SURGE ARRESTOR #IJ LAI-NC
28 GEN RPM SENSOR LOSS 1 GRSL-NC
28 GEN REMOTE START GRS-NC
28tt22SOLIDlLAI-C WHITE o0 tt22 SOLID l GRSL-G 0 00 0 tt22 SOLID GRS-C o0
RED 29 O O 29 O O O 29 O O O O C
GROUND BAR THEFT J GND-NC
30 GEN OVER VOLTAGE J GOV-NC
30 GEN REMOTE STOP f GRSP-NC
30 C22SOLIDlGND-C W#ITF 0 22 SOLID l( GOV-C 22 SOLID GRSP-C 0 0 o
31 0 0 0 O O O
32 GEN UNDER VOLTAGE) GUV-NC 31 r
GEN HIGH TEMPI GHT-NC 31 C0000o22SOLID1GUV-G O 22 SOLID 1 GNT-C O 0 O
33 O O O O 33 33 O O O C
TO TBG IN BYPASS GEN OVER FREQ GOF-NC
NC -RED) 34 O O O 22 SOLID { GOF-C
34 O O 0 0 34 O O O O C
TO TBG IN BYPASS 35 35 35
G-BLK)
36
0 0 0 o
GEN UNDER FREQ GUF-NC
36
0 0 0 o
ATE, NORMAL POWER TBI-I-NC RED
36
0 0
0 0 o 22 SOLID GUF-C 0 0 0 0 22 SOLID TB1-3-C WHITE 0 0
37 0 0 37 0 0 0 o RED 37 0 o C
GEN LOW OIL PRES GLOP -NC
38 ATS STANDBY POWER TBI-G-NC
38
TB #15 WHITE E39 0 0 0 o tt22 SOLID GLOP-C O O O 22 SOLID TBI-B-C WHITE o
RED 0 39 0 0 o o 39 o 0 0 E
UPSI RUN1r UP51 12-NC
41
GEN HIGH OIL PRES CHOP -NC
40 ATS REMOTE START RS-NC
41 022SOLIDlUPSI14-C WHITE 0 22 SOLID GHOP-C o a o o tt22 SOLID PS-C 0 o a o
RED 41 o 41 0 0 0 o 41 0 o o [
UPSI BYPASS UPSI 12-NC
42 GEN OIL PRES FAIL GOPF-NC
42
r
TRANSFER COMPLETE 1 75I-2-NC
42 C22SOLIDUPSI17-C NHITE 0 0 22 SOLID GOPF-G o o tt22 SOLID l TBI-4-C o O O
RED 43 0 0 43 0 0 0 0 43 o 0 0 0 [
UPSI POWER FAIL 1 UPSI 12-NC 44
f
GEN OIL TEMP FAIL J GOTF-NC
44 E22SOLIDlUPSIII-C NHITE 0 o tt22 SOLID l GOTF-C4 0 0 0 0 0 0 0 o
RED 45 45 0 0 0 0 45 0 0 0 o C
UPSI FAIL UPSI 12-NC GEN PRE HIGH OIL GPNOPW-NC
22 SOLID f UPSI 14-C WHITE Al0 0 PRESSURE WARNING GP#OPW-C
46 0 0 00 0 46 0 0 00 0 C
RED 0 o tt22 SOLID 47 0 o a o 47 0 0 0 0
UPSI LOW BATTERY UP51 12-NG GEN PRE HIGH OIL GPNOTW-NC
422 SOLID f UPSI I7-C NHITEO O TEMP WARNING GPHOTW-G 48O O O 48Vtt22SOLID4949RED O O 0
UPSI SUMMARY f UPSII2-NC GEN START INHIBIT1 GSIOP-NC[#
22 50 50
SOLID UP51 II-CWHITE 0 OIL PRESSURE i GSIOP-C O O O O O 0 0 O
22 SOLID
CONNECTOR CONNECTOR CONNECTOR
AT BLOCK AT BLOCK AT BLOCK
STAIYPS AND SEALS
ALARM BLOCKS
SCALE: NONE
a=mW'ZQ
Zmi 9i w3 i
aQazapp[
ZaEwZpO ~
zwaqtyu_ Foal
Wi
Z F iv
w
W
W Q
J U)
Q
Do
ON
QOJ
Q
r
r
W
J
LL
O
V
w
w C0 CID
Q
z Z
L
O Q
CL Ca
DATE:
3/8/16
SALES MANAGER:
D. Brunswick
DRAWN BY:
J. Wagner
SERIAL NUMBER:
1603-105
SCALE 24X36:
NONE
SHEET:
El m2
CONNECT EQUIPMENT GROUND TO GROUND
BAR HERE TO THIS LOCATION ONLY
Al id
SERVICE GROUND
COIL EXIT
INSTALL GBKI4 TO SIDE OF ENCLOSURE WITH #10 BOLTS AND
NUTS. (REMOVE PAINT AND USE NO-OX) GROUND EACH DSWPH03
TO GBKI4. CONNECT #2 TO THE ENCLOSURE WITH 2-HOLE LUG
PLACE #2 AS CLOSE AS POSSIBLE TO THE #10 BOLTS) AND
RUN AS SHOWN TO THE MGB AND CONNECT WITH A 2-HOLE LUG.
0
O
a
E
101
2 GREEN TO UPS
TERMINAL STRIP
WALL D
4'-I"
TI' -8"
lr
CONNECT CABLE LADDER TO GROUND
BAR MERE TO THIS LOCATION ONLY
ROW 3
WALL C
3'-0"
ROW 2 ROW I
M
I I® ®II — II 11 p II 11 11 U II
loom
11
MISM MOM! I u u e I)
c
N
N
B 11
O C
N N
c
w
L J FolI I
lIX3> I I II
WALL A
GROUNDING LAYOUT
SCALE 1/2"=1'-0"
CABLE LADDER:
L CABLE LADDER IS TO BE 8'-0" A.F.F. AND INSTALLED IN ACCORDANCE WITH ARTICLE 392
OF THE NEC LEVEL TO WITHIN 1/8" IN 10' OR SIMILAR.
GROUNDING:
I. ALL GROUNDING EXCEPT FOR CABLE LADDER TO CONFORM TO ARTICLE 250 OF THE NEC.
2. CABLE LADDER GROUNDING TO CONFORM TO ARTICLE 392.60 OF THE NEC.
2 BARE STRANDED COPPER IPGB ON 4" PANDUIT
STANDOFFS EVERY 24" (PRT. #PP2S-5I0-C), CONNECTED
TO MASTER GROUND BAR. ALL CONNECTIONS SHALL BE
MADE WITH BURNDY COMPRESSION FITTINGS AND ALL
BENDS SHALL BE 8" MIN. RADIUS.
WALL B
v
ww
p? z W W Z W Z
weQoE>-op[Qz a
z= w
NQ
a uEa y}C' 0.'
VUOQ3j zF
LL
F WW
J C a
J
C 0
o 2 C
ONX
O- 2
oo C r
c: J
LL
TE:
3/
8/1 SALES
MANAGER: D.
Brunswick DRAWN
BY: J.
Wagner SERIAL
NUMBER: 1603-
10y SCALE
24X36: NONE
SHEET:
E2
INSULATOR
CEILING
THREADED ROD \
CABLE LADDER
8) 1/2" FLAT WASHER
8) 1/2" LOCK WASHER
8) 1/2"-11 NUT
BRACKET, HANGER, PLATE
WITH 129/32" SLOT
LADDER INSTALLATION DETAIL
SCALE: NONE
EXTENSION BARS
THROUGH WALL
WALL MOUNTING
BRACKET
0
0 19,
0 p 0
0 0 0
0 B, OO00
0 0 0 0
0 0 0 0 00000
0 0
0 0 0 0 0 0 0
0
0 0
0
0
GROUND BAR
INTERIOR GROUND BAR DETAIL
SCALE: NONE
1/4"-20
2 HOLE LUG
HEX BOLT
6 GREEN I/4" FLAT
WASHER
PRIMARY GROUND" `-1/4" LOCK
BAR/METAL WASHER
ENCLOSURE
LOCK NUT
HEX BOLT
LOCK WASHER
I. SELECT BOLT LENGTH TO PROVIDE A MINIMUM OF TWO EXPOSED THREADS,
2. BURNISH MOUNTING SURFACE TO REMOVE PAINT IN THE AREA OF LUG CONTACT.
3. APPLY ANTI -OXIDANT COMPOUND TO MATING SURFACE OF LUG AND WIPE CLEAN
EXCESS COMPOUND.
4. ONLY ONE LUG PER SET OF BOLTS.
GROUNDING CONNECTION
SCALE: NONE
3/4" PVC FOR
GROUND ACCESS
I PVC CAST IN WALL
450 PVC NIPPLE DETAIL
SCALE: NONE
INSTALLED ON SITE)
EXTERIOR GROUND BAR DETAIL
SCALE: NONE
CABLE LADDEP
CORNER
HOLE LUG
6 GREEN
1/4"
55, 1/4"-20
TO MGB
6 GRE
GROUN
6 GRE
RACK
TO Ml
EQUIPME
GROUND B
6 GREEN
GROUND B
TYI
EXAMPLE 1 EXAMPLE 2
I. IF RACK HAS A GROUND BUS BAR (EXAMPLE 1 8 2) ALL EQUIPMENT GROUNDS SHALL
BE CONNECTED TO THE EQUIPMENT BUS BAR VIA #/n GRN. A #2 GRN SHALL THEN BE
TAKEN FROM THE GROUND BUS BAR TO THE EQUIPMENT GROUND BUS CONDUCTOR.
2. ALL EQUIPMENT GROUND SPLICES SHALL BE TAPED WITH GREEN TAPE.
EQUIPMENT GROUNDING ELEVATION EXAMPLE
REFER TO ONLY WHEN EQUIPMENT IS INSTALLED. VIEWED FROM REAR OF EQUIPMENT
SCALE: NONE
GROUND
USE WHITE BASE AS TEMPLATE t DRILL 1/4" HOLES
6"O.C. STAGGERED FROM LEFT TO RIGHT AND SECURE
DURO-LAST VINYL BASE WITH 1/4"XI-1/4" NYLON ANCHOR
4 VINYL BASE DURO-LAST #1571 (WHITE)
FASTEN WITH NYLON DRIVE RIVETS
BOLT (NO METAL TO BE USED)
K WASHER
2" GROUND STRAP
BROWN VINYL COVER
DURO-LAST #1572 (TAN)
GROUND RING (REFER TO
MANUFACTURERS
INSTALLATION INSTRUCTIONS)
a`.
d BUS
BASE It COVER SHALL
EXTEND G" BELOW
GRADE, CUT OFF EXCESS
GROUND BAR/STRAP/COVER DETAIL
SCALE: NONE
TO IPGB RING
11 METAL DOOR FRAME
551 1/4"-20 BOLT II
WITH FLAT WASHER 2 HOLE LUG G 2" REF.
T ItB 54205
ACROSS EVERY LADDER TO LADDER
CONNECTION
CABLE LADDER BOND DETAIL
SC:` -LE: NONE
DOOR
1/4" X I" BOLT t
1/4" FLAT WASHER
HINGE LINE DOOR BONDING
STRAP
r%e%f%o Qf1Al1'liRlf_ 11CTA ll
SCALE: NONE
C" TAP
YC2C4
1/B" MIN.
1/4" MAX.
8" RADIUS ALL AXES
2 STRANDED
NON -JACKETED
GREEN
TO GROUND ITEM--
IPGB RING GROUND TAP
SCALE: NONE
VTrl_T ]gawVDIRT
NEWTON BRACKET 2105
LOCATE ON CABLE
LADDER EVERY 18"
2 STRANDED GREEN SECURE
TO BRACKET WITH TY-WRAPS
NEWTON BRACKET GROUND
SCALE: NONE
BRACKET PANDUIT
PP25--510-C
TY-RAP Tt5
10 X 1-1/2" HHW
PLATED SHEET
METAL SCREW
2 STRANDED'
NON -JACKETED
2) TY-RAP T48 TY24M
FEED ONE OVER AND
ONE UNDER
IPGB GROUND INSTALLATION
SCALE: NONE
GROUNDING NOTES:
I. USE NO-OX AT ALL GROUND TERMINATIONS.
2. IN PLACES WHERE THE GROUND BUS WIRE IS LESS THAN 2" FROM METALLIC OBJECTS AND NOT
BONDED, NEATLY TAPE THE SECTION WITH GREEN TAPE. WHERE NECESSARY, REMOVE THE TIE
WRAPS (AND RE -INSTALL AFTER TAPING) AND TAPE C-TAPS FIRST AND THEN TAPE PAST
THEM IN A CONTINUOUS WRAP.
3. PLACE HEAT SHRINK TUBING ON GROUND BAR PIGTAILS THAT GROSS WALL MOUNTED CONDUIT.
4. ALL DOORS TO BE GROUNDED TO THEIR FRAMES WITH WELDING WIRE. USE #2 GAUGE WELDING
WIRE AND STANDARD BURNDY TWO -HOLE LUGS. PLACE A 2" BAND OF GREEN TAPE AT EACH END
OF THE JUMPER.
5. INTERIOR PERIMETER GROUND BUS (IPGB): #2 BARE STRANDED COPPER AROUND INSIDE
PERIMETER OF BUILDING WITH EACH END LUGGED TO THE GROUND BAR.
6. BONDING JUMPERS: #6 GREEN STRANDED INSULATED WIRE FROM METALLIC EQUIPMENT TO IPGB
AND ACROSS LADDER RACK SPLICES/CROSSES/TEES,
7. EQUIPMENT GROUND BUS: #2 GREEN RAN OUTSIDE EACH RUN OF CABLE LADDER WITH NEWTON
CLIPS (#2106G).
G" TAP #2 STRANDED
YC2C2—\ GREEN
2 STRANDED
1/8 MIN GREEN
1/4" MAX.
8" RADIUS ALL AXES
EQUIPMENT GROUND TAP
SCALE: NONE
STAMPS AND SEALS
u w z
os'd wr8 °
F f l wFmnftn_@Q S
imp
t o
zo
ca
z
A4 c
w
ftS d
Qr' 0
J cv
I
co
0 +
U I
O
O O
rTl G CD
WGo
q
a
W J
v+ W P
oaco
O Z
O N z
FOX
00 0
ce
P
r
DATE:
3/5/16
SALES [MANAGER:
D. Brunswick
DRAWN BY:
J. Wa ner
SERIAL NUMBER:
1603-105
SCALE 24X36:
NONE
SHEET:
Ell
k
uw.w
5/32" DIA. l
TYP 8 PLACES)
11A. NOLE
TYP 4 PLACES)
WIREMOLD SIMPLEX COVER
SCALE: NONE
2 EACH REQUIRED
5/32" DIA. ,, 1_
TYP 8 PLACES)
A. HOLE
TYP 4 PLACES)
WIREMOLD SIMPLEX COVER
SCALE: NONE
EMT CONNECTOR
EMT CONDUIT
RIGID COUPLING
CABLE LADDER J
90° LIQUIDTITE CONNECTOR
STRAIGHT LIQUIDTITE
CONNECTOR
CEILING
LIQUIDTITE
CONDUIT
WIREMOLD
4
WIREMOLD CONNECTION
SCALE: NONE
DO NOT RUN CONDUITS THROUGH CABLE LADDER)
CONDUIT SHALL LINE-UP WITH BLANK COVER PLATE)
REAR WALL
TOP TOP —
CEILING
3"x3"xl/4" ALUMINUM
ANGLE
114" BOLT AND NUT
R (USE 2 EACH
EMOLD RUN)
WIREMOLD
WIREMOLD INSTALLATION DETAIL
SCALE: NONE
INSULATORS SHALL BE PLACED AS
CLOSE TO CABLE LADDER AS POSSIBLE
CIRCUIT #I CIRCUIT #17 CIRCUIT
CIRCUIT #2 CIRCUIT #I8 CIRCUIT
CIRCUIT #3 CIRCUIT #Iq CIRCUIT
CIRCUIT #4 CIRCUIT #20 CIRCUIT
CIRCUIT #1 CIRCUIT #17
CIRCUIT #2 CIRCUIT #18
CIRCUIT #3 CIRCUIT #lq
CIRCUIT #4 CIRCUIT #20
CIRCUIT #5 CIRCUIT #21 CIRCUIT
CIRCUIT #6 CIRCUIT #22 CIRCUIT
CIRCUIT #7 CIRCUIT #23 CIRCUIT
CIRCUIT #84 CIRCUIT #24 CIRCUIT
STOP
IT #1
IT #2
IT #3
IT #4
24 EACH REQUIRED
CIRCUIT #q
CIRCUIT #10
CIRCUIT #5
CIRGUIT #6
CIRCUIT #7
CIRGUIT #8
CIRCUIT #21
CIRCUIT #22
CIRCUIT #23
CIRCUIT #24
CIRCUIT 325
CIRCUIT #26
CIRCUIT #q
CIRCUIT #10
CIRCUIT #5
CIRCUIT #6
CIRCUIT #7
CIRCUIT #8
CIRCUIT #11 CIRCUIT #27 CIRCUIT #11
CIRCUIT #12 CIRCUIT #28 CIRCUIT #12
CIRCUIT #q CIRCUIT #25 CIRCUIT #q
CIRCUIT #10 CIRCUIT #26 CIRCUIT #10
CIRCUIT #11 CIRCUIT #27 CIRCUIT #II
CIRCUIT #12 CIRCUIT #28 CIRCUIT #12
CIRCUIT #13 CIRCUIT #29 CIRCUIT #13
CIRCUIT #14 CIRCUIT #3 CIRCUIT #14
GROUND TO BE PLACED TOWARD THE TOP CIRCUIT #15 CIRCUIT #31 CIRCUIT #15
TOP HALF OF WIREMOLD) CIRCUIT #16 CIRCUIT #32 CIRCUIT #16
WIREMOLD COVER SHALL BE LABELED CIRCUIT #13 CIRCUIT #2q CIRCUIT #13
WITH THE PANEL # IN THE CENTER,
uPSITPI
CIRCUIT #14 CIRCUIT #30 CIRCUIT #14
AND THE CIRCUIT # UNDER EACH CIRCUIT #15 CIRCUIT #31 CIRCUIT #15
RECEPTACLE AS SHOWN BELOW: CIRCUIT #16 CIRCUIT #32 CIRCUIT #16
UPSITPI UPS2TP2 UPS2TP2 UPSITPI UPSITP3 UPS2TP4
a ea la la ROW 3 ROW 2 ROW I
0 0 0 0
o
Oa
a o 0
Da Oa Oa
0 0 0
0 0 0 0
CKT #1 GKT #2 CKT #3 CKT #4
GROUND TO BE PLACED TOWARD THE BOTTOM WIREMOLD CIRCUIT LOCATIONBOTTOMHALFOFWIREMOLD)
SCALE: NONE
SIMPLEX RECEPTACLE _ORIENTATION
SCALE: NONE
RECEPTACLES TO BE PLACED ON REAR SIDE OF EQUIPMENT.
UPS] CIRCUITS TO BE ON TOP HALF OF WIREMOLD.
UPS2 CIRCUITS TO BE ON BOTTOM HALF OF WIREMOLD.
STAMPS AND SEALS
Lo 'Cf
co 00
4
z0
OQ
O>
OLo
q
0
I
O
CX? coWcoLoN
w
W
m J
ui
Q to
J
0J
O®
N
bo
1
r
r
DATE:
3/8/16
SALES MANAGER:
D. Brunswick
DRAWN BY:
J. Na ner
SERIAL NUMBER:
1603-105
SCALE 24X36:
NONE
SHEET:
E 3
IL 50' OF GENERATOR
NTROL AND ALARM
RES
WALL D
Al
4'-2" MAX. lk
F
WALL C
vi u
il i ll 11 11 11 I
NMI IWO
1I/! I! IIIII 1 1- III,
mol L,J Ilril 1IlrmlEmmillmilim
iillilfl- IIIIIII!
I IIIIIIII
i
1 III Illlrl
III I-
IIII Ir
I
I r
j
11 1
III!
lllllll
IIIIIIII
I I 111
III r'I
1 11
unui innn ni lll
WALL A
ELECTRICAL DIMENSIONS
SCALE 1/211=1'-0"
COMMERCIAL POWER:
I 120/240VAC, 300AMP SINGLE PHASE SERVICE. I
CONDUIT RUNS:
I. ALL CONDUIT RUNS TO BE EMT UNLESS STATED OTHERWISE.
2. ALL CONDUIT RUNS TERMINATING AT SERVICE ENTRANCE EQUIPMENT SHALL CONTAIN BONDED
BUSHINGS.
3. NIRENAYS CARRYING 3 OR MORE CURRENT CARRYING CONDUCTORS SHALL BE DEBATED PER
TABLE 310-15(B)(3)(o) OF APPLICABLE EDITION OF THE NEC.
4. CONDUIT FILL IS BASED ON CHAPTER 9, APPENDIX C OF THE NEC.
WALL B
STAMPS AND SEALS
zl-=
mNWWDWD
Ou GrI
ZDxaDONwz ozw
8a i ax a"BQ WZ !-
Hwya 0 aw Ng
yZjzUQ wo
D-<, Z
a j
O
Q
zo
O
0
co
0
U
I 0
00
W
c\? co 0
0
10
Z
w
O J
J) Z W
aco
J
p 00
Q
ONH
XU 2
0 U w
W
J
W
DATE:
3/
8/16 SALES
MANAGER: D.
Brunswick DRAWN
BY: J.
Na ner SERIAL
NUMBER: 1603 -
105 SCALE
24X36: NONE
SHEET:
E4
v
a
COIL 50' OF
ALARM WIRE
TO TB6 IN BYPASS
C-BLK)
DSWPH03 MODULE
SCALE: NONE
TO TB6 IN BYPASS
NC -RED)
TBI
TO TERMINAL
BOARD
LI
L2
120V SURGE PROTECTOR MODULE
SCALE: NONE
TO T66 IN BYPASS
C-BLK)
WNITE/GREEN
TO T66 IN
NC -RED)
2 a
BYPASS
TBI
o o a
5
3 o r
UPSI 12-NC ll UPSI RUN 4
UPSI 14-C J #22 SOLID 7 GREEN/WNITE 0 0
UPSI 12-NC 1 UPSI BYPASS JUMPER s o 0 0
UPSI 17-C J #22 SOLID
W41TE/BROWN 7 0 0 0
UP51 12-NC UPSI POWER FAIL 18
BROWN/WHITE EV 0 0 0
UPSI II-C 22 SOLID 1q
WNITEBLUE 9 0 o p
UPSI 12-NC lL UP51 FAIL 10
UP51 14-G J #22 SOLID 21 GRAY/WNITE
ORANGE/WNITE 19
UPSI 12-NC UP51 LOW BATTERY p
12
UPS 17-C 22 SOLID 9
WHITE/ORANGE 0 0
BLUE/WHITE 13 0 0 0
UPSI 12-NC UP51 SUMMARY 6
WNITE/GRAY 14
UPSI ll-C 22 SOLID
UPS1 ALARM CONNECTIONS
SCALE: NONE
NOTE:
I. LEIBERT 20kVA UPS 25-PIN INTERFACE CABLE CONNECTION
DAI
DOORra ''ALARM
HTA
HIGH
TEMP
ALARM
SERI ES
ALARM
LOW
TEMP
ALARM
150I4
LOW
HUMIDITY
ALARM
NIGH
HUMIDITY
ALARM
DI
SMOKEq-- I ALARM
MISC. DIAGRAMS
SCALE: NONE
ALARM
UP52 12-NC UPS2 RUN
UP52 14-C 22 SOLID
UPS2 12-NC lLUPS2 BYPASS
UP52 17-C J #22 SOLID
UP52 12-NC UPS2 POKER FAIL
UPS2 Il-C J SOLID
UP52 12-NC l#
22
L UP52 FAIL
UP52 14-C J #22 50LID
UPS2 12-NC UP52 LOW BATTERY
UPS2 17-C 22 SOLID
UP52 12-NC UPS2 SUMMARY
UPS II-C 22 SOLID
UPS2 ALARM_CON_NEC_TIONS
SCALE: NONE
NOTE:
I. LEIBERT 20kVA UPS 25-PIN INTERFACE CABLE CONNECTION
LAI
PRIMARY SECONDARY
SUPPRS50R SUPPRESSOR
C NO NC C NO NC
u
C NC
NOT USED NOT USED
LA2
PRIMARY SECONDARY
SUPPRESOR SUPPRESSOR
C NO NC C NO NC
u
C NC
NOT USED NOT USED
ONE -LINE WIRING DIAGRAM
SCALE: NONE
NO -L -
BLACK
C WHITE USE 3/22 AWG SOLID WIRE
NC
RED
NON-SHEILDED)
ALARM WIRE COLOR CODE
SCALE: NONE
SWITCH
CIRCUIT \_
BREACKER ff
PHOTO CELL LIGHT
EXTERIOR LIGHT CIRCUIT
SCALE: NONE
CIRCUIT
BREAKER
POWER
FAIL
ALARM
POWER FAIL DIAGRAM
SCALE: NONE
HVAG-1 FAIL HVAC-2 FAIL
ALARM ALARM
NC NC
0 0
c c
HVAC_FA_I_L DIAGRAM
SCALE. NONE
STAMPS AND SEALS
Q NOul
zZi1-taW W
a ZE 4
o
J
ui
In
Q
NV
V
W
J
W
DATE:
3/8/16
SALES MANAGER:
D. Brunswick
DRAWN BY:
J. Na ner
SERIAL NUMBER:
1603-105
SCALE 24X3G:
NONE
SHEET:
E5
3/81, "
TOP VIEW
C
REAR VIEW
3/4" DIAMETER
m
5 n
3/4"-10 FERRULE
2) PLACES EACH (2) PER
FERRULE, MIN. INTERIOR LIFT
DEVICE
3 1/2"
HOLD
3/4" DIAMETER
TYP)
SIDE VIEW
LIFT DEVICE NOTES:
I. FLOOR AREA < 240 50. FT. 4 INTERIOR LIFT
DEVICE PER FLOOR
2. FLOOR AREA > 240 50. FT, 8 INTERIOR LIFT
DEVICE PER LOAD
INTERIOR LIFT -DEVICE
SCALE: 1-1/2" = 1'-0"
FLOOR LAYOUT
SCALE:
INTERIOR LIFT DEVICE SEE DETAIL THIS SHEET
4 BAR GR. 60
3 SIDES #4 GR. 60 HOOK BAR
3/16"
A °
T
4 " ° mri - %
1/2" x 5/16" STEEL ANGLE
m
SIDE VIEW
TOP VIEW
FLOOR INTERIOR LIFT DEVICE DETAIL
SCALE: 1-1/2" = 1'-0"
4 GR 60 REBAR WITHIN I" OF
TOP SURFACE OF FLOOR
SEE INTERIOR LIFT DEVICE DETAIL
PERIMETER ANGLE
DOOR EMBED PLATE (TYP)
DETAIL FOR DOOR LOCATION
SCALE: 1-1/2" = 1'-0"
THIS DETAIL APPLIES ONLY WHEN LIFT
POINT 15 UNDER DOOR OPENING
NTERIOR LIFT DEVICE
SEE DETAIL THIS SHEET
3" MIN RADIUS
4
DO NOT SPLICE
WITHIN 24" EA.
SIDE OF LIFT
DEVICE
E a
OVERLAP 36" MIN.
n MID FLOOR CROSS TIE
SCALE: NONE
INTERIOR LIFT DEVICE
SEE DETAIL THIS SHEET
3" MIN RADIUS
OVERLAP 36" MIN.
END FLOOR CROSS TIE
5 SCALE NONE
ONE PER LIFT DEVICE PAIR REBAR: #4 GR 60.
3AR AT
JRS
4 60 GkAur KCDAK A I i= v- .
TYPICAL FLOOR REBAR LAYOUT
SCALE; NONE
REBAR NOTES:
SHORT (TENSION) DIRECTION I" FROM BOTTOM OF CASTING BED
LONG (TENSION) DIRECTION 1-3/4" OR JUST ABOVE TENSION REBAR
CASTING DETAIL NOTES:
REINFORCING BAR:
REINFORCING BAR TO BE ASTM A615, LATEST REVISION, PLAIN BILLET STEEL
REINFORCING BAR GRADE 60 OR HIGHER IS NOT PERMITTED FOR EMBED PLATE EXTENSIONS.
REINFORCING BAR FOR SLAB STRENGTH AND T*S TO BE ASTM A615 GRADE 60.
LIGHT RUST ACCEPTABLE PER ASTM A615, SECTION 12, SCALING AND PITTING NOT
PERMITTED.
REINFORCING BAR BEND RADII SHALL NOT BE LE55 THAN SIX BAR DIAMETERS.
LOCATION AND FORMING TOLERANCES: +/- 1/8"
MAXIMUM CONCRETE COVER BETWEEN CASTING BED AND PRIMARY SLAB STRENGTH
REINFORCING BAR SHALL NOT EXCEED V.
TRANSVERSE REINFORCING BARS (PRIMARY STRUCTURAL REBAR) SHALL NOT BE SPLICED.
LONGITUDINAL REINFORCING BARS (Tt5 REBAR) MAY BE SPLICED - AT MOST EVERY 48" WITH
A MINIMUM OVERLAP OF 18"
WELDING:
WELDING PRACTICE FOR REINFORCING BAR TO CONFORM TO AWS DIA, LATEST EDITION
WELDING PRACTICE FOR STRUCTURAL STEEL TO CONFORM TO AWS DI.1, LATEST EDITION
DO NOT WELD REINFORCING BAR WITHIN THREE BAR DIAMETERS OF A BEND.
DO NOT WELD GRADE 60 REINFORCING BAR.
GRADE 40 REINFORCING BAR REQUIRED TO BE WIRE TIED CONNECTIONS ONLY.
CONTINUOUS ELECTRODES TO CONFORM TO AW5 A5.15 OR AW5 A5.20, LATEST EDITION.
OTHER ELECTRODES TO CONFORM TO APPLICABLE AW5 STANDARDS.
OTHER MATERIALS
PLATE AND ANGLE TO BE ASTM A36 Fy = 36 KSI (MIN)
HEADED STUDS TO CONFORM TO ASTM AI08 AND AWS D1J. HIGH STRENGTH STEEL 15 NOT
PERMITTED.
HOLES MUST BE DRILLED AND REAMED OR PUNCHED. PLASMA CUTTING OR TORCHING IS NOT
PERMITTED.
FLOOR -WALL CONNECTION PLATES ARE NOT TO BE SPACED MORE THAN 3' APART.
WELD PLATE HP-11 MAXIMUM SPACING 3'-0" ON LONG WALLS.
CASTING LEGEND
LIFTING FERRULE WELD CLIP
FLOOR WELD CLIP
0 STANDARD WELD CLIP
EXTERIOR LIFTING DEVICE
ROOF LIFTING PIN
CASTING TOLERANCES
WALL PANELS
SEE NOTE I) TOLERANCE FLOOR PANELS TOLERANCES
LENGTH 1/8 LEVEL 1/8"
WIDTH I/8 SQUARE 1/8"
DEPTH 1/8 VERTICAL WARP 1/8"
EDGE SWEEP 3/8"
EMBED PLATE POSITION 1/4
EMBED PLATE TIP/FLUSH 1/8
PENETRATION LOCATION
SEE NOTE 3) I/8
BOWING 1/4
WARPING
114 IN 10' LEAST
DIMENSION, MAX.
SQUARE (SEE NOTE 2) 1/8
NOTES:
I. MAXIMUM DEVIATION OVER PANEL
2. MAXIMUM DIFFERENCE IN DIAGONAL DIMENSIONS
3. UNLESS NOTED OTHERWISE
STAMPS AND SEALS
ww Z _
aQa mw Q Q
r -I!
aQ wz oat
Z p
No—Nf-Z zm
on o u
Q u -
z F- a
A`
N O
Lo
d0 O
zo
co
w
0 O)
LoLo
cq
41 1
O co
0
O O
W c co
co
W
v, LITJ
F-
Q
i'^^
v
J Q
V
O CV p
X O
co LL
1
f
DATE:
3/8/16
SALES MANAGER:
D. Brunswick
DRAWN BY
J. Na ner
SERIAL NUrIBER:
1603-105
SCALE ' 24X36:
NONE
SHEET:
si
4
W
WALL A LAYOUT
SCALE: 3/8"=1'-0"
WALL C LAYOUT
SCALE:
2'-7° v I, 1'-2
c
m
v
4) 1 1/2" PVC
2X4 BLOCKOUT
r ,
c
P
r ,
PVC
1'-4" 3'-0" TYP 2'-6 I/4" SIESMIC PLATE
5 _10 SEE STUD TABLE
THIS PAGE
WALL B LAYOUT
SCALE:
4'-0" TYP v 11-
WALL D LAYOUT
SCALE:
SMIC PLATE
E STUD TABLE
IS PAGE
CASTING LEGEND
LIFTING FERRULE WELD CLIP
FLOOR WELD CLIP
STANDARD WELD CLIP
EXTERIOR LIFTING DEVICE
ROOF LIFTING PIN
STUD TABLE
SHELTER
SHELTER WIDTH (FEET)
LENGTH
FEET) 8' 10' 12' 13' 14'
NUMBER OF STUDS
8' 6 6 5 5 5
9' 7 6 6 6 5
10, 7 7 6 6 6
11' 8 7 6 6 6
12' 8 7 7 7 6
13' q 8 7 7 7
14' 9 8 a 7 7
15' 10 q 8 8 7
16' 10 q 8 8 8
17' 11 q q 8 8
18, 11 10 9 q q
19, II 10 q q 9
20' 12 11 10 q q
21' 12 11 10 10 10
22' 13 II 1 II 10 10
23' 13 12 1 II II 10
24' 14 12 1 11 II II
25' 14 13 12 11 II
26' 15 13 12 12 11
27' 15 14 12 12 12
28' 16 14 13 12 12
29' 16 14 13 13 12
30' 17 15 14 13 13
31' 17 15 14 13 1 13
32' IS 16 14 14 13
33' 18 16 15 14 14
34' 19 16 15 14 14
36' Iq 17 15 15 14
36' 20 17 16 15 15
37' 20 18 6 16 15
38' 21 18 16 16 15
39' 21 IS 1 17 16 16
40' 21 Iq 1 17 17 16
EXTERIOR FINISH SCHEDULE
ITEM SURFACE FINISH PAINT COLOR
ROOF TROWELED SMOOTH
SEALED, ELASTOMERIC COURSE
PAINT
TELECOM BROWN
WALLS
EXPOSED WASHED
AGGREGATE
OKITE STAIN (2 COATS)
DOORS STEEL, RATED PAINT TELECOM BROWN
JOINTS AS FINISHED SEALED PER 'DETAILS SHEET TELECOM BROWN
CASTING TOLERANCES
WALL PANELS
SEE NOTE 1) TOLERANCE FLOOR PANELS TOLERANCES
LENGTH 1/8 LEVEL
WIDTH 1/8 SQUARE
DEPTH 1/8 VERTICAL WARP
EDGE SWEEP
EMBED PLATE POSITION 1/4
EMBED PLATE TIP/FLUSH 1/8
PENETRATION LOCATION
SEE NOTE 3) 1/8
BOWING 1/4
WARPING
1/4 IN 10' LEAST
DIMENSION, MAX.
SQUARE (SEE NOTE 2) 1/8
NOTES:
1. MAXIMUM DEVIATION OVER PANEL
2. MAXIMUM DIFFERENCE IN DIAGONAL DIMENSIONS
3. UNLESS NOTED OTHERWISE
STAMPS AND SEALS
AAmmank
LoLb
0
rVr1 .Q
zo
cd
O jp
c
OwLOO
cli
I
A co
0 cv
d
U I
00
W GmGo
w
w
co
pA
w z
Z
cl)
Qo® v
N
J
Q
b
r
r
DATE:
3/8/16
SALES MANAGER:
D. Brunswick
DRAWN BY:
J. Wagner
SERIAL NUMBER:
1603-105
SCALE 24X36:
NONE
SHEET:
S 2
a