HomeMy WebLinkAboutCONSTRUCTION PLAN PAGE 1-5W ? LU $ k 2'-51/211eoo,ol LL?Ul j iiQ< Z F pCHa1l in1 r = 4 60 GRADE REBAR (TYP) N EXTERIOR FACE 12 CENTERS (TYP) 41 J ° a a a ° ° 3/8" PLYWOOD d O 3 5/8" #4 60 GRADE REBAR ON HORIZONTAL 1" CHAIRS 3 O 12" ON CENTERS TYPICAL) o 7 w TEMPORARY 2x4 FRAMING -10 I/2" il_1± cd TYPICAL SHORTWALL DETAIL TYPICAL WALL REBAR LAYOUT A m1 SCALE: 1-1/2" = 1'-0" SCALE: 1-1/2" _ -0" _ IVIICROFLECT PANEL DETAIL ^ !~ SCALE: NONE O Oj GO'y l0 LocQ J I 0 ca 0 ald U I 0 0 0 cv co 14 3„ 3" (+1/2" TYP) to hi K0 16 74 3 TRIM BAR (TYP) r-- 4 TYPICAL OPENING DETAIL SCALE: NONE ri a LL V+ J J F- W 4 REBAR = o,/^ TYP) v/ Q 0 J - Z Oc s ' II— I ON Q 00 J J r 'Q r DOOR REBAR DETAIL 5 SCALE: NONE WALL PANELS SEE NOTE I) CASTING TOLERANCES TOLERANCE FLOOR PANELS TOLERANCES LENGTH 1/8 LEVEL WIDTH 1/6 SQUARE DEPTH 1/8 VERTICAL WARP EDGE SWEEP EMBED PLATE POSITION 1/4 EMBED PLATE TIP/FLUSH 1/8 PENETRATION LOCATION SEE NOTE 3) 1/5 BOWING 1/4 WARPING 1/4 IN 10' LEAST DIMENSION, MAX. SQUARE (SEE NOTE 2) 1/8 NOTES: I. MAXIMUM DEVIATION OVER PANEL 2. MAXIMUM DIFFERENCE IN DIAGONAL DIMENSIONS 3. UNLESS NOTED OTHERWISE to J lqe I.L. O U w LLI z z U Z w w w L Ll STAMPS AND SEALS DATE: 3/B/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Wagner SERIAL NUMBER: 1603-105 SCALE 24X36: NONE SKEET: S2.1 4 a 3AR AT AIRS 4 60 G n va. f", 1 1 14 TYPICAL ROOF REBAR_ LAYOUT SCALE: NONE REBAR NOTES: SHORT (TENSION) DIRECTION I" FROM BOTTOM OF CASTING BED LONG (TENSION) DIRECTION 1-3/4" OR JUST ABOVE TENSION REBAR ROOF LAYOUT SCA:-E 3/8"=1'-0" AFTER PLUG REMOVAL, FILL VOID WITH NON -SHRINK GROUT 4-TON LIFT PIN WITH RUBBER PLUG, TIED TO SURROUNDING REBAR FOR STRENGTH ELECTION AT LIFTING PIN_ A` / 6'-1 1/4" V-0" TYP lkIk C3 SECTION AT ROOF PIN SCALE: 1-1/2' -0 CASTING LEGEND LIFTING FERRULE WELD CLIP FLOOR WELD CLIP 0 STANDARD WELD CLIP EXTERIOR LIFTING DEVICE ROOF LIFTING PIN CASTING TOLERANCES WALL PANELS SEE NOTE I) TOLERANCE FLOOR PANELS TOLERANCES LENGTH 1/8 LEVEL 1/8" WIDTH 1/8 SQUARE 1/8" DEPTH 1/8 VERTICAL WARP 1/8" EDGE SWEEP 3/8" EMBED PLATE POSITION 1/4 EMBED PLATE TIP/FLUSH 1/8 PENETRATION LOCATION SEE NOTE 3) I/8 BOWING 1/4 WARPING 1/4 IN 10' LEAST DIMENSION, MAX. SQUARE (SEE NOTE 2) I/8 NOTES: I. MAXIMUM DEVIATION OVER PANEL 2. MAXIMUM DIFFERENCE IN DIAGONAL DIMENSIONS 3. UNLESS NOTED OTHERWISE STAMPS AND SEALS W W Z _ amN6tuQ [] zru u-r0 3 iia" 7=g g t Ei IT t5 711 W I u~ L N9N 3Q W 0cl) W Z J Fm a040v oNLL o X 0 o 2 co r W J q L in r. CD3 u C c w Z z w z a O Q w w n f) DATE: 3/8/1(0 SALES MANAGER: D. Brunswick DRAWN BY: J. Na ner SERIAL NUMBER: 1603-105 SCALE 24X36: NONE SHEET: S 3 a STANDARD THERMOBOND WELD CLIP TREMCO DYMONIG JOINT SEALANT OR EQUAL TYP AT ROOF TO WALL CLIPS TREMCO DYMONIC JOINT — SEALANT OR EQUAL THERMOBOND LIFTING FERRULE/WELD CLIP EXTERIOR FINISH AS NOTED ON 514EET A2 4" CONCRETE WALL ROOF-4" THICK EDGE WITH 1/4" PER FT. SLOPE PANELING FRAMING INSULATION IN WALLS INSULATION IN CEILING TYPICAL ROOF TO WALL SECTION DETAIL SCALE: 1-1/2" = 1'-0" EXTERIOR FINISH AS NOTED ON 514EET A2 THERMOBOND SEISMIC WELD CLIP TREMCO DYMONIC JOINT — SEALANT OR EQUAL TYP AT WALL TO WALL CLIPS 3/16" a n THERMOBOND WELD CLIP EXTERIOR FINISH AS NOTED ON SHEET A2 4" CONCRETE WALL N 4" CONCRETE WALL e FRAMING PANELING INSULATION IN WALLS TYPICAL WALL TO WALL SECTION DETAIL SCALE: 1-1/2" = 1'-0" 4" CONCRETE WALL EXTERIOR FINISH AS NOTED ON SHEET A2 THERMOBOND STANDARD WELD CLIP TREMCO DYMONIC JOINT SEALANT OR EQUAL TYP AT WALL TO FLOOR CLIPS a INSULATION IN WALLS PANELING FRAMING BASE COVE FLOOR TILE CONCRETE FLOOR THERMOBOND FLOOR WELD CLIP TYPICAL WALL TO FLOOR SECTION SCALE: 1-1/2" = 1'-0" INJECTED FOAM INS DOOR JAM INJECTED FOAM INS DOOR JAM INSULATION 1 TYPICAL DOOR SECTION DETAIL SCALE: 3/4" = I'-O" OR 1E BUILDING SECTION SCALE: 3/4" = I'-0" CROSS SECTION NOTES: L FLOORS ARE TO BE WAXED AND SEALED BEFORE SHIPPING. CONSTRUCTION MATERIALS: INTERIOR FINISH: FLOOR: 1/8" X 12" X 12" VINYL TILE WITH 4" BASE COVE WALLS: 1/2" FRP COVERED PANELING (GLASS "C" MINIMUM) CEILING: 1/2" FRP COVERED PANELING (CLASS "C" MINIMUM) INSULATION: WALLS: 1 1/2" THERMAX FOAM INSULATION (R-11) ESR-165q CEILING: 2 1/2" THERMAX FOAM INSULATION (R-Iq) ESR-165q FRAMING: WALLS: 2" X 3" FURRING STRIPS ON SIDE AT 24" O.C. CEILING: 2" X 3" FURRING STRIPS ON END AT 24" O.C. CONCRETE: FLOOR: 5000psi LIGHTWEIGHT WALLS: 5000psi LIGHTWEIGHT CEILING: 5000psi LIGHTWEIGHT STAMPS AND SEALS I.L W MW Z W O Q coV, J LLI V O N X 0 O m z t' V r J LL Lo C V y r w z z W z o a rY rY rL Q DATE: 3/5/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Nociner SERIAL NUMBER: 1603-105 SCALE ' 24X36: NONE SHEET: S4 0 0 0 0- 0 0 /0 0 0 LOCATE BOTTOM ABOVE 0 0 0 0 0 /0 LOCATE BOTTOM ABOVE Im 0 SHELTER SUPPORT oa 0000 ono ono ono UP TO 20 FT LONG SHELTER CENTER OF GRAVITY 9 0 0 0 0 0 OVER 20 FT LONG SHELTER CENTER OF GRAVITY S REMOVE PROTRUDING FOR SHIPMENT i YI REMOVE PROTRUDING HARDWARE FOR SHIPMENT OPEN SIDED MODULAR SHELTER CENTER OF GRAVITY S TER SUPPORT PROTRUDING ARE FOR SHIPMENT TRANSPORT NOTES: I. CARTAGE COMPANY TO EXECUTE TIE DOWN, DETERMINE ADEQUACY OF TIE DOWN AND 15 RESPONSIBLE FOR LOCATING SHELTER G.G. FOR EQUIPMENT REQUIREMENTS AND DOT COMPLIANCE. 2. REMOVE AND SHIP LOOSE ALL FIXTURES PROTRUDING OVER WIDTH LIKELY TO BE DAMAGED 3. COVER OPENINGS WATERTIGHT. 4. PROVIDE DRIVER WITH SET OF LIFTING DRAWINGS AND INSTRUCTIONS TO DELIVER LIFTING DRAWING WITH SHELTER AT SITE OFF-LOAD. 5. INSPECT SHELTER FOR DAMAGE BEFORE RELEASING DRIVER. DUNNAGE AND TIE DOWN NOTES: I. BLOCK SHELTER ONLY AT THE ENDS, UNDER THE END WALLS. 2. BLOCK SHELTER ABOVE HIGHEST POINT OF TRAILER CAMBER BY AT LEAST 1 1/2". STAMPS AND SEALS a zQ a awla- z azF zaLi„ `o a WPM N OC p W 2 Z J O O N w O a Bo U) 7 10 LL Lon i U W w co LLJ Ory DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Na ner SERIAL NUMBER: 1603-105 SCALE 24X36: NONE SHEET: T 1 P r EDGE PROTECTORS MUST BE USED TO PREVENT DAMAGE TO THE CONCRETE CORNERS 4) POINT OPTION 1 BUILDING LIFT PREFERRED METHOD) SLINGS VERTICAL EDGE PROTECTORS MUST BE USED TO PREVENT DAMAGE TO THE CONCRETE CORNERS SEE INSTALLATION INSTRUCTIONS THIS PAGE FOR ALLOWABLE ANGLE OF LIFTING SLING 0 EDGE PROTECTORS USED TO PREVENT I TO THE CONCRETE f SEE INSTALLATION I THIS PAGE FOR ALL ANGLE OF LIFTING S EDGE PROTECTORS MUST USED TO PREVENT DAMAG TO THE CONCRETE CORNEF SEE INSTALLATION IN5TRU THIS PAGE FOR ALLOWABL ANGLE OF LIFTING SLING 4) POINT OPTION 2 BUILDING LIFT SEE TABLE 5) EDGE PROTECTORS MUST BE USED TO PREVENT DAMAGE TO THE CONCRETE CORNERS SEE INSTALLATION INSTRUCTI THIS PAGE FOR ALLOWA ANGLE OF LIFTING SL EXTERNAL FEATURES 4) POINT OPTION 3 BUILDING LIFT TABLE 1 4) POINT LIFT OPTION 2 LIFT DEVICE SEPARATION (5) MINIMUM HOOK HEIGHT (H) 10'-0" 13'-q" III -oil 15' -2" 12' -0" 6' -6" 3'-0" 17'-10" 14' -0" I9' -3" 15'-0" 20'-8" 6'-0" 22'4" 17'-011 23'-5" 18'-0" 24'-g" Iq'-0" 26'-2" 201-0" 27' -6" 4 POINT LIFT OPTIONS 1 SCALE: NONE €°9 i" rl 8) POINT OPTION 1 BUILDING LIFT PREFERRED METHOD) 8) POINT OPTION 2 BUILDING LIFT SEE TABLE EDGE PROTECTORS NU USED TO PREVENT DA TO THE CONCRETE COF SEE INSTALLATION INS THIS PAGE FOR ALLOW ANGLE OF LIFTING SLIP EXTERNAL FEATURES 8) POINT OPTION 3 BUILDING LIFT TABLE 1 8) POINT LIFT OPTION 1 LIFT DEVICE SEPARATION (5) MINIMUM HOOK HEIGHT (H) 6' -0" 13' -q" 7'-0" 151-2" 8' -0" 10 -6" q'-0" 17'-10" 10'-0" I9'-3" 11'-0" 20'-8" 12'-0" 22'-0" 8 POINT LIFT OPTIONS SCALE: NONE MAXIMUM ANGLE PERPENDICULAR TO WALL DO NOT EXCEED BOLT INSTALLATION: 1. SNUG (NO PLAY) PLUS 1/8 TURN MAX. 2. DO NOT DRIVE WITH HIGH PRESSURE IMPACT WRENCH. w 1 MAXIMUM ANGLE PARALLEL TO WALL DO NOT EXCEED oi4 -iv X 2 3/4" L. (MIN.) GR. 8 OR 3/4"-10 X 2 3/4" L. (MIN.) A4g0 BOLT WITH FLAT WASHERS 3 END INSTALLATION AND SLING LIMITS J SCALE: NONE ER TYP) SEE NOTE 5) FOUNDATION PLAN VIEW INSTALLATION NOTES: 1. ALL FOUNDATION WORK BY OTHERS AND SUBJECT TO LOCAL INSPECTION. 2. FOUNDATION SURFACE SHALL BE LEVEL TO WITHIN +/- 1/8" PER 10 LINEAL FEET IN ANY DIRECTION. 3. FOUNDATION SHALL BE SQUARE TO WITHIN +/- 1/4". 4. TIE DOWN PLATES, IF USED MUST BE ENTIRELY ABOVE GRADE. 5. SHELTER MUST BE SHIMMED TO LEVEL ABOVE IRREGULARITIES IN THE SLAB AND BUILDING FLOOR SYSTEM. SHIM HARDNESS NOT LESS THAN 60 DUROMETER. OR COMPRESSIVE STRENGTH 9,000 PSI MINIMUM. SHIMS NOT LESS THAN 3" SQUARE, THICKNESS AS REQUIRED, 6. INSPECT FOUNDATION FOR DEBRIS AND REMOVE BEFORE SETTING SHELTER. SHELTER MUST BE SHIMMED 4 SHELTER SHIMMING SCALE: NONE RIGGING NOTES: I. SHELTER MUST BE LIFTED ONLY AT POINTS PROVIDED, USING APPROPRIATE SPREADER BARS AND SLINGS, AND WITHIN THE LIMITS SHOWN ON THIS DRAWING. 2. UNLESS OTHERWISE APPROVED OR INDICATED, LIFT ONLY THE SHELTER SELF -WEIGHT. DO NOT LIFT THE SHELTER WITH ADDITIONAL EQUIPMENT INSIDE. 3. INSPECT EACH LIFT DEVICE FOR FOR CRACKS, WARPING OR OTHER DEFECTS BEFORE INSTALLING ON SHELTER. DO NOT USE A LIFTING DEVICE THAT HAS ANY CRACKS, QUESTIONABLE WELDS, IRREGULAR OR ELONGATED HOLES, OR 15 BENT OUT OF SHAPE. 4. INSPECT BOLTS BEFORE INSTALLATION. DO NOT USE ANY BOLTS THAT HAVE DAMAGED THREADS, ARE BENT, APPEAR ELONGATED OR ARE MALFORMED IN ANY WAY. S. DO NOT ROUTE SLING NEAR HVAC SYSTEMS G. REMOVE OR PROTECT DOOR HARDWARE AND OTHER PROTRUSIONS FROM DAMAGE. 7, RIGGER 15 TO PROVIDE ALL EQUIPMENT ABOVE THE THERMOBOND EXTERIOR LIFTING DEVICE. THE RIGGER 15 RESPONSIBLE FOR ENSURING THAT THE SAFETY REQUIREMENTS LISTED HEREIN ARE MET. 8. RIGGING SHALL CONFORM TO APPLICABLE LOCAL, STATE AND FEDERAL REQUIREMENTS. q. IF SHELTER 15 DELIVERED WITH TEMPORARY SHIPPING WALLS OR ANY OTHER TEMPORARY STRUCTURE INSTALLED FOR TRANSPORT, DO NOT REMOVE BEFORE SHELTER PLACEMENT. 10. DO NOT USE SINGLE HOLE POSITIONS FOR LIFTING. 11. DO NOT SET THE SHELTER ON AN UNEVEN OR UNSTABLE SURFACE. STAMPS AND SEALS a n wor o d o Z p FZgokwZKo - t W> ~ idEfz F- a li W J J J Do JN X H O co G 00 z 1 r r DATE: 3/8/16 SALES MANAGER: D. Brunswick DRAWN BY: J. Wagner SERIAL NUMBER: 1603-105 SCALE 24X36: NONE SPEET: T2 3 w