BUILDING PLAN PAGE 1-15
-----m-a 1 j"xIj'x12"GA. ANGLE FASTEN TO SLEEVE (TYP) HEMMED"S"SUP BREAKAWAY CONN. (TYP.) INSULATION FRAME BRACE & CURTAIN FRAME DUCTSIZEAS SHOWN ON PLANS STAINLESSSTEEL NEGATOR CLOSURE SPRING GALV. STEEL SLEEVE -GAUGE IN ACCORDANCE WITH SMACNA. FASTEN TO FIRE DAMPER FRAME WITH INTERLOCKING JOINTS. DROP CURTAIN TYPE WITH 100% FREE AREA, (U.L. LABELED) fUSIBLE LINK (U.L.) INSULATED ACCESS DOOR. ACCESS DOOR MUST BE SIZED AND LOCATED FOR PERSONAL MAINTENANCE ACCESS TO RESET FIRE DAMPER. MIN, 2 HINGES AND 2 LATCHES 2" X 2'V X 3/16" GALV SEAL ALL AROUND WITH A SEALANT THAT WILL REMAIN FLEXIBLE BOTTOM OF BUILDING STRUCTURE DUCTMATE 16 GAUGE SHEET METAL SLEEVE SET IN WALL STL. ANGLE NOTE: EXISTING WALL OR MIN. OPENING IF FIRE DAMPER IS REQUIRED CHASE WALL PER SPECIFICATIONS MAKE SLEEVE LARGE ENOUGH TO SUIT DAMPER SELECTED DIRECTION OF AIR PRESSURE VERTICAL FIRE DAMPER (LOW PRESSURE) DETAIL SCALE=(NSSJ I I Y A C FLAN DUCT ACCESS PANEL DETAIL SCALE=(N.T.S.) A IILAI\II 111 I]^V 1„TI I" SPACE -PACK WITH FIBROUS PACKING SLEEVE SET IN WALL DUCTMATE JOINTS A SEALANT THAT WILL REMAIN FLEXIBLE 4" SPACE -PACK WITH FIBROUS PACKING DETAIL OF DUCT PASSING THRU WALLS SCALE=(N.T.S.) SCALE 1/8" = I' -Oil GENERAL NOTES: I. ROUTE REFRIGERANT LINES FROM EACH AHU UP ABOVE CEILING, THRU EXTERIOR WALL, THEN DOWN IN METAL HAT CHANNEL TO RESPECTIVE CU. 2. ROUTE CONDENSATE DRAIN FROM EACH AHU (I' BELOW 5 TONS , I I/4' ABOVE 5 TONS) TO FLOOR DRAIN IN RESPECTIVE MECH. ROOM - PROVIDE AIR GAP. 3. PROVIDE MOTORIZED DAMPER IN EACH OUTDOOR AIR INTAKE. DAMPER SHALL OPEN WHEN RESPECTIVE SYSTEM CYCLES ON, CLOSE WHEN OFF. 4. LOCATE FILTERS AT AHU CABINETS - NO FILTERS IN RETURN GRILLS. 5. COORDINATE EXACT AIR DEVICE LOCATIONS WITH CEILING / LIGHTING LAYOUT. KEY NOTES: lO 24'X24' TRANSFER GRILL WITH FLEX TRANSFER DUCT. 2O ROUTE 6"e EXHAUST UP TO ROOF JACK. OUTDOOR AIR CALCULATIONS AHU I 16 PPL x 5 CFM = 80 CFM O.A. 3,100 SO. FT. x 0.06 CFM = 186 CFM O.A. 266 CFM O.A. REQUIRED 300 CFM O.A. PROVIDED AHU 2 13 PPL x 5 CFM = 65 CFM O.A. 2,450 SO. FT. x 0.06 CFM = 147 CFM O.A. 212 CFM O.A. REQUIRED 250 CFM O.A. PROVIDED AHU 3 20 PPL x 5 CFM = 100 CFM O.A. 2,250 SO. FT. x 0.06 CFM = 135 CFM O.A. 235 CFM O.A. REQUIRED 250 CFM O.A. PROVIDED AHU 4 8 PPL x 5 CFM = 40 CFM O.A. 1,200 SO. FT. x 0.06 CFM = 72 CFM O.A. 112 CFM O.A. REQUIRED 125 CFM O.A. PROVIDED AHU-5 10 PPL x 5 CFM = 50 CFM O.A. 1,500 SQ. FT. x 0.06 CFM = 90 CFM O.A. 140 CFM O.A. REQUIRED 150 CFM O.A. PROVIDED Z N O r F Ld U W � cr 0 H O N U Z O U W Z 0_ Z j O o w W > ~O w z a � I w Ld N W > N w 0 DO 7AL ■■■■■MEM Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 a .o C jOf as u wW 0 3 U gCr W o O z in w oov J CD Li M U Q Cn _ T W z O Z Q M a O P o� z o w x W W 3 W a w o 'o o x a a V. U- ENGINEER SEAL :4uu. c. 0 R 1 �tlR , ye S f ALAI % Eric J. Svoboda, PE P.E. No. 60982 I SHEET TITLE I HVAC PLAN I I-` `''; 11-28-2018 I DRAWN: EJS APPROVED: EJS I DRAWING NUMBER I SHEET 2 OF 3 17001-15 STAINLESS STEEL BAND 3" SHAFT INSERT 1 1/2' INSULATION BRANCH DUCT BUTTERFLY DAMPER J OPERATOR ON 1 1/2' STAND-OFF TO ALLOW FOR INSULATION USE ROUND SHEET METAL - DUCT HERE TO LIMIT FLEX DUCT TO 10'-0"IN LENGTH 6'SADDLE - INSULATE BELLS CEILING DIFFUSER (M'-) ' TAKE -OFF FITTING DIRECTION SECURE FLEX DUCT TO TAKE -OFF OF AIR I FITTING WITH STAINLESS STEEL FLOW I SCREW DRIVER OPERATED BAND BRANCH I FLEXIBLE DUCT DUCT I I STRAP-, DAMPER SADDLE 1 1/2' STRAPS TO STRUCTURE INSULATED FLEX DUCT RADIUS NOT LESS THAN 1 1/2 x DUCT DIA. 3' SHAFT INSERT STAINLESS STEEL BAND 1 L CEILING NOTE USE BORDER TYPE 1 WHERE IN HARD CLGS. - BORDER TYPE C WHEN EXPOSED CEILING DIFFUSER. INSULATE BELLS. SEE HVAC FLOOR PLAN FOR LOCATION OF DIFFUSER. CEILING 1 1/2" INSULATION NOTE: USE BORDER TYPE 1 WHERE IN HARD CLGS. - BORDER TYPE C WHEN EXPOSED �— PROVIDE GASKET BETWEEN TAKE OFF FITTING AND BRANCH DUCT. A FLEX DUCT CONNECTION DETAILS IL�7:11 L MOISTURE SIGHT GLASS NOTES: 1. PROVIDE ACCUMULATOR IF DEVELOPED LENGTH IS GREATER THAN 50' 2. PROVIDE REFRIGERANT PIPE SIZES RECOMMENDED BY MFG. 3. SEE ALSO REFRIGERANT SYSTEM NOTES CHARGE VALVE W/CAP IF NOT PROVIDED WITH UNIT CONDENSING UNIT SEE DETAIL & SCHEDULE BASE SENSING BULB FILTER DRYER WITH REPLACEABLE CORE ISOLATION VALVES (TYPICAL) BALL TYPE ISOLATION VALVES IF NOT PROVIDED WITH UNIT FLEX - DUCT SUPPORT r6X48 rr ION MECH. ROOM FLOOR PROVIDE EMERGENCY OVERFLOW SENSOR WATER GARD PRIMARY PAN SENSOR #101475B OR SECONDARY DRAIN HOLE SENSOR #401490B WITH ALARM. WATER GARD, INC. 12211 CEDAR GAP, HOUSTON, TX 77072 (PH 888-652-9800) * PLACE AIR HANDLING UNIT IN THE ROOM SO THAT SERVICE TO THE UNIT & FILTER REPLACEMENT CAN BE ACCOMPLISHED. B I VERTICAL AHU DETAIL AHU I THRU 3 SCALP=MTS.) SUCTION LINE LIQUID LINE THREADED CAP WITH 1/2"O HOLE DRILLED IN TOP, HAND TIGHTENED. SLOPE TO DRAIN THREADED CAP, HAND TIGHTENED AIR - HANDLER UNIT DRAIN PAN CASING SLEEVE -UNION RETURN AIR DUCT - SEE PLAN FOR SIZE SUPPLY AIR DUCT - SEE PLAN FOR SIZE PROVIDE TRANSITION TO SUIT MFG. OPENING � FLEX UNIT - SSEEIRSCH DDUULEEG C.D. TRAP FLOOR CONSTRUCT PLENUM SUPPORT BASE FRAME FROM IX I' X' STEEL 8 ENCLOSE WITH I e DUCT BOARD - SEAL WITH TAPE aMASTIC. WALL DUCT SUPPORT PROVIDE EMERGENCY OVERFLOW SENSOR WATER GARD PRIMARY PAN SENSOR #401475B OR SECONDARY DRAIN HOLE SENSOR #401490B WITH ALARM. WATER GARD, INC. 12211 CEDAR GAP, HOUSTON, TX 77072 (PH 888-652-9800) PLACE AIR HANDLING UNIT IN THE ROOM SO THAT SERVICE TO THE UNIT & FILTER REPLACEMENT CAN BE ACCOMPLISHED. C VERTICAL AHU DETAIL AHU 4 & 5 S('ALL-(N I S , NOTE: 1. FILL TRAP MANUALLY ON INITIAL START-UP, 2. PIPE SIZE SHALL NOT BE LESS THAN DRAIN PAN CONNECTION SIZE. 3. A = lZ TIMES FAN SUCTION S.P. B = 1/2" PLUS FAN DISCHARGE S.P. 4. ALLCONDENSATEPIPING TO BE PVC. 5. INSULATE ALL DRAIN LINES WITH Y^ ARMAFLEX SECURE TO STRUCTURE ABOVE AS RECOMMENDED BY SMACN14 1 20 GA GALV. METAL STRAP Jl or i 'SHEET METAL SCREW, RIVET OR BOLT TO BOTH SIDES OF DUCT. TYPE 'A' TYPICAL RECTANGULAR DUCT ELK kD RATED �TENER 36" DIA. MAX TYPICAL ROUND DUCT DUCT SCHEDULE DUCT DIMENSIONS INCHES TYPE HANGER UP TO 18 A 19 TO 30 A B 30 TO 60 B NOTE: 8'-0" MAX HANGER SPACING SECURE TO STRUCTURE ABOVE AS RECOMMENDED BY SMACNA I_HAN GER ROD S-I-Z-E�Y" L TYPE'B' WxThr GALVANIZED ANGLE HANGER RODS, WIRES OR STRAPS -f BAND ONE HALF -ROUND MAY BE USED IF DUCT SHAPE IS MAINTAINED TYPICAL AIR COOLED CONDENSING UNIT. DO NOT LOCATE UNIT WHERE THE UPBLAST WILL STRIKE ANY OVERHANG. LOCATE UNIT MINIMUM OF 2'-0' FROM BUILDING EXTERIOR WALL ANCHOR UNIT TO PAD WITH MIN. 1/4' DIA.— EXPANSION BOLTS S 1 1/2" EMBEDMENT DEPTH & NEOPRENE PAD. (TYPICAL FOR 4) SUCTION & LIQUID REFRIGERANT LINES RUN REFRIGERANT LINES SHORTEST DISTANCE TO BLDG. EXTERIOR WALL. SEE PLANS FOR CONTINUATION. PAD TO BE 4' LARGER ALL AROUND THAN UNIT, FURNISHED WITH #4 REBARS AT 6' O.C. BOTH WAYS 4 8' THICK CONCRETE PAD. 4' ABOVE GRADE AND 4" BELOW GRADE MIN. 3000 PSI NOTE: INSTALL TO WITHSTAND 170 MPH WINDS. D I AIR COOLED CONDENSING UNIT DETAIL 3/8" DIA. THREADED STEEL HANGER ROD& SEE PLAN FOR EXHAUST DUCT CONTINUATION AND TERMINATION DUCT SLEEVE—\ EXHAUST DUCT / FLEX. CONNECTION / TO EXHAUST FAN J CABINET FAN UPPER ATTACHMENTS IN ACCORDANCE WITH SMACNA DETAILS RUBBER -IN -SHEAR VIBRATION ELIMINATORS (TYPICAL FOR ALL 4 HANGER RODS) Q Y 0 z 0 U z z 0 U Z 0 o w O z i w a m Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing DeAign C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 a 0 U w a0 w� Sit ait J w w D_ _! 0 o It U 0 a _ m rn W 0 Q M 2 Q 0 0 - 3 0 _ _J w Z cai D i �oo U u w 3 w E L� 'o o E a o= Lo ow d ENGINEER SEAL N o 80982 :+ STATE OF 1,41 CEILING Eric J. Svobodo, PE P.E. No. 60982 n w nuue+rs, xnc M ne P s w a EXHAUST FAN CEILING GRILLE R AnM V MT P EMMN" BL, W SWLL 9E Pm I.uaam' n[ sne c�rmrxrmPm�, run PRACE EIG➢Fm01G, QIG NL RI(MS fdSFRVFD. I SHEET TITLE I MECHANICAL DETAILS IJJVC VNI G: 11-28-2018 O C DRAWN: EJS APPROVED: EJS DRAWING NUMBER M-3 SHEET 3 OF 3 E I REFRIGERANT PIPING SCHEMATIC SCALE M.T.S.) F CONDENSATE DRAIN TRAP DETAIL = SCALE=(N.T.S.) G DUCT SUPPORT DETAILS M.T.S.) H CEILING CABINET Ex HAUST FAN DETAL = - - SCALE _ 17001-15 THERMOMETER POSITIONED TO BE READ FROM FLOOR (RANGE 0-200° F) TYP. 110 DEG HOT WATER SUPPLY 3/4 EXPANSION TANK M — 3/4" �_ PIPE U ISOLATION GATE NION (TYP) COLD WATER SUPPLY �� VALVE (TYP) PBT RELIEF VALVE (SETTING BY MFR. OF HEATER) FULL SIZE OF VALVE ELECTRIC WATER OUTLET HEATER No ROUTE TEMP. AND PRESS. VALVE OUTLET TO 6" ABOVE PAN DRAIN PAN ROUTE 3/4" PAN DRAIN TO SHELF MOP BASIN BELOW. O MECHANICAL TEMPERING /MIXING VALVE SET AT MAX 110 DEG OUTPUT ELECTRIC WATER HEATER DETAIL N.T.S. ELECTRIC WATER HEATER MIN. 6' AFF DRIP PAN 3/4" PLYWOOD 1/4" NUT AND BOLT, TYPICAL WALL -2"x 2% 1/8" ANGLE ROUTE TO 2'-0"f (2 BRACKETS REQ'D.) MOP BASIN BELOW /2" ANCHOR BOLT V0(2 R EXPANSION BOLT PER BRACKET) NOTE: N.S.P.C. 10.16.7 REQUIRES: WHERE A HOT WATER STORAGE TANK OR INDIRECT WATER HEATER IS LOCATED AT AN ELEVATION ABOVE THE FIXTURE OUTLETS IN THE SYSTEM A VACUUM RELIEF VALVE SHALL BE INSTALLED ON THE STORAGE TANK. WALL MOUNTED ELECTRIC WATER HEATER DETAIL WITH DRIP PAN N.T.S. FUNNEL FOR CONDENSATE 3"0 FLOOR DRAIN FPRIMER Aa24" AP IMAX DICATED TRAP UARD II GUARD NOT USED. II INSERT II II — II II II 4" DEEP TRAP 43"RAIN U FLOOR DRAIN WITH TRAP GUARD INSERT N.T.S. PLUMBING FIXTURE SCHEDULE CODE DESCRIPTION HW CW WASTE VENT TRAP REMARKS WATER CLOSET, FLOOR MOUNTED, AMERICAN STANDARD MADERA MODEL WC-1 2234.001, VITREOUS CHINA, ELONGATED _ 1" 4" 2" INT EQUAL BY KOHLER OTTOTO. RIM, 1-1/2" TOP SPUD, OPEN FRONT SEAT LESS COVER, SLOAN 111 FLUSH VALVE. WATER CLOSET, FLOOR MOUNTED, AMERICAN STANDARD MADERA MODEL WC-2 3043.001, SAME AS WC-1, EXCEPT ADA — 1" 4" 2" INT EQUAL BY KOHLER OR TOTO. COMPLIANT. URINAL, WALL HUNG, AM. STD. WASH- BROOK FLOWISE MODEL, VITREOUS CHINA, U-1 3/4" TOP SPUD, SLOAN 186-1 FLUSH VALVE. — 3/4" 2" 1 1/2" INT EQUAL BY KOHLER OR TOTO. LAVATORY, COUNTERTOP, AM. STD. CADET EQUAL BY KOHLER OR TOTO. MODEL, 1 1/4" 'P' TRAP, GRID DRAIN. PROVIDE BELOW DECK L-1 CHICAGO FAUCET MODEL 802-V VANDAL 1/2" 1/2" 2" 11/4" 11/4" MECHANICAL MIXING/ RESISTANT TEMPERING VALVE FOR HW - SET AT MAX 110 DEG. LAVATORY, WALL HUNG W/ FLOOR MOUNTED CONCEALED ARM CARRIER, AM. EQUAL BY KOHLER OR TOTO. STD. LUCERNE MODEL, VITREOUS CHINA, 4" PROVIDE BELOW DECK L 2 HIGH BACK, 1 1/4" 'P' TRAP, GRID DRAIN. 1/2" 112" 2" 1 1/4" 1 1/4" MECHANICAL MIXING/ CHICAGO FAUCET MODEL 802-V VANDAL TEMPERINTN G VALVE FOR HW - RESISTANT. ADA COMPLIANT. SETMAX1DEG. SERVICE SINK, MUSTEE 62M DURASTQNE MOP BASIN WITH MOP HANGER, BUMPER GUARDS, WALL GUARDS, HOSE & HOSE S-1 HOLDER. CHICAGO FAUCET 540- 1/2" 1/2" 3" 2" 3" LD897SWXF WITH WALL BRACE, 3/4" HOSE THREAD, VACUUM BREAKER & PAIL HOOK. ELECTRIC WATER COOLER, ELKAY EWC-1 LZSTL8WSVRSK EZH2O BOTTLE FILLING 1/2" 2" 1 1/4" 1 1/4" EQUAL BY OASIS OR HALSEY COMBINATION KIT, SPLIT LEVEL, 8GPH, ADA — TAYLOR COMPLIANT. PLUMBING EQUIPMENT SCHEDULE CODE DESCRIPTION REMARKS EXTERIOR CLEAN OUT, ADJUSTABLE TOP, CO-1 INTERNAL CLOSURE PLUG, HEAVY DUTY COVER SET IN 12" X 12" X 4" PLATE. CONCRETE CO-2 WALL CLEAN OUT PLUG WITH CHROME PLATED BRASS COVER PLATE. FLOOR CLEAN OUT, ADJUSTABLE TOP, INTERNAL CO-3 CLOSURE PLUG, POLISHED BRONZE COVER PLATE. ELECTRIC WATER HEATER, A.O. SMITH DEL 30, PROVIDE EXPANSION TANK 30 GAL, 4.5KW, ASME CONSTRUCTION, T&P PER CODE. SET AT 130 DEG. EWH-1 RELIEF VALVE, 208V, 1 PHASE PROVIDE WITH MECHANICAL TEMPERING / MIXING VALVE SET AT MAX 110 DEG OUTPUT. FLOOR DRAIN, JOSAM SERIES 30000A, C.I. BODY, POLISHED BRONZE STRAINER, INTEGRAL TRAP, TRAP PRIMER TO BE FD-1 WITH CONDENSATE FUNNEL & TRAP GUARD CONNECTED TO NEAREST INSERT. SINK. HOSE BIBB, ALL BRASS, 3/4" HOSE CONNECTION, HB-1 VACUUM BREAKER, LOOSE KEY STOP. PROVIDE SHUT-OFF TO EACH HOSE BIBB PER CODE, PLUMBING SYMBOLS Q NOTES: r SYMBOLS DESCRIPTION 0 — — — COLD WATER (CW) -- HOT WATER (HW) z o I. PLUMBING CONTRACTOR IS TO FURNISH AND INSTALL ALL SEWER (S) PLUMBING FIXTURES COMPLETE AS LISTED IN "PLUMBING FIXTURE SCHEDULE VENT LINE (V) o 2. PLUMBING CONTRACTOR MAY USE SCHEDULE 40 OR 80 TYPE I, HWR— RECIR. HOT WATER GRADE I, POLYVINYL CHLORIDE PIPE FOR ALL SOIL, WASTE AND o 0 CID -- CONDENSATE DRAIN VENT PIPING WHERE PERMITTED BY LOCAL CODES. WHERE PVC PIPING IS NOT PERMITTED BY LOCAL CODES, USE STANDARD z X - EXISTING PIPE WEIGHT CAST IRON PIPING. ALL PIPING ABOVE GRADE MAY HAVE HUBLESS FITTINGS. PLASTIC PIPING SHALL NOT BE USED IN A e CONNECT TO EXISTING RETURN AIR PLENUM. COORDINATE THIS REQUIREMENT WITH U) —SD— STORM DRAIN (SD) H.V.A.C. CONTRACTOR. o m P PUMP 3. PROVIDE SHUT-OFF GATE VALVES ON ALL EQUIPMENT a HOSE VTR VENT THRU ROOF BIBBS, $ STOP COCKS IN HOT AND COLD WATER PIPING TO ALL PLUMBING FIXTURES. WC WATER CLOSET CC) 4. ALL WATER PIPING BELOW GRADE SHALL BE TYPE "L" SOFT o 0 UR URINAL TEMPERED COPPER AND ALL WATER PIPING ABOVE GRADE SHALL m BE TYPE 1" HARD TEMPERED COPPER. o HL HAND LAVATORY o L-(No) LAVATORY 5. INSTALL I" FOAM RUBBER INSULATION ON ALL HOT WATER I az Fort Pierce PIPING ABOVE a BELOW GRADE. ALL JOINTS IN INSULATION ARE HB HOSE BIBB TO BE TAPED. Engineering, Inc. SS SERVICE SINK 6. ELEVATION OF ALL FLOOR DRAINS SHALL BE HELD 1/2" BELOW Dependable rnbi gDesi Electrical & Plumbin FINISH FLOOR TILE. C.A. No.28173 DF DRINKING FOUNTAIN EWC ELECTRIC WATER COOLER 7. ALL MATERIAL AND INSTALLATIONS SHALL BE IN ACCORDANCE WITH ALL LOCAL AND STATE PLUMBING AND MECHANICAL CODES, EWH ELECTRIC WATER HEATER INCLUDING THE STANDARD BUILDING, PLUMBING AND MECHANICAL CODES, NFPA, ASME, ASHRAE, ASA AND AGA. GWH GAS WATER HEATER SH SHOWER 8. THE SANITARY SYSTEM INCLUDES CONNECTION TO FIXTURES, 1 RUNNING OF SOIL AND WASTE LINE AND SOIL AND VENT HS HAND SINK SANITARY SEWER SYSTEM AND/OR SEPTIC TANKS AND DRAIN FIELDS AND ALL ITEMS AS SHOWN ON DRAWINGS. VENT STACKS FD FLOOR DRAIN SHALL EXTEND THROUGH ROOF WITH LEAD FLASHING. RD ROOF DRAIN 9• THE DOMESTIC WATER SYSTEM INCLUDES CONNECTIONS TO THE 315 South 7th Street -0o— GATE VALVE DESIGNED SYSTEM, CONTROL VALVES AND PIPING TO PLUMBING Fort Pierce, FL. 34950 �— GLOBE VALVE FIXTURES, INCLUDING CONNECTIONS TO EQUIPMENT FURNISHED BY Phone: 72 672-4636 OTHERS. Fax: 772 672-4637 672-4637 —�— CHECK VALVE 10. PIPE INSTALLATIONS AND MATERIALS SHALL BE AS REQUIRED TO oa%vuo- BACK FLOW PREVENTER MAINTAIN FIRE RATINGS WHERE REQUIRED BETWEEN FLOORS AND/OR BETWEEN UNITS. VALVE IN YARD BOX (TYPE AS NOTED) II. ARRESTERS SHALL BE INSTALLED WHERE NECESSARY TO PRESURE RELEIF VALVE (RV) PREVENT WATER HAMMER. WATER METER 12. COPPER PIPING WHERE USED SHALL NOT CONTACT DISSIMILAR METALS OR MASONRY. PROVIDE ISOLATING BUSHINGS WHEN a —p ELBOW - UP CONNECTING TO ANY DISSIMILAR METALS. > FE u 0 —E) RISE OR DROP 13. PLUMBING CONTRACTOR SHALL COORDINATE WITH ARCHITECT FOR —per- CONCENTRIC REDUCER DETAILED DIMENSIONS AND LOCATIONS OF ALL FIXTURES AND Q� EQUIPMENT AND FOR ANY CHANGES IN LAYOUT. u a w �- DIRECTION OF FLOW F w a 14. PLUMBING CONTRACTOR SHALL MAKE ALL TEST AND ADJUST- W U C.O� CLEAN OUT (RISER) MENTS AS REQUIRED, UPON COMPLETION OF WORK AND PRIOR TO cD p'Oj m o M FINAL ACCEPTANCE BY OWNER. —C.O. CLEAN OUT moo- C.O. 15. AFTER COMPLETION OF THIS WORK, THE CONTRACTOR SHALL WALL CLEAN OUT OBTAIN A CERTIFICATE OF FINAL INSPECTION AND APPROVAL to FROM ALL AUTHORITY'S HAVING JURISDICTION. {� PLUGGED PIPE 16. ALL WORKMANSHIP, MATERIALS AND APPARATUS UNDER THIS SHOWER HEAD CONTRACT SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY THE OWNER. PUMP W/FLOW DIRECTION o 17. THESE DRAWINGS ARE PREPARED PER ESTABLISHED INDUSTRY � 01 0) FLOW SWITCH STANDARDS AND REPRESENT THE ENGINEER'S DESIGN CONCEPT. THEY w 4 m PRESSURE SWITCH ARE NOT INTENDED TO PROVIDE EVERY DETAIL OR CONDITION O z a o 3: REQUIRED TO CONSTRUCT THE BUILDING. THE CONTRACTOR THROUGH Q a 5 w ,A,B,C,D WATER HAMMER ARRESTER SUBMITTALS AND OTHER COORDINATION EFFORTS IS FULLY z � o � 0 WITH P.D.I. SIZE RESPONSIBLE FOR PROVIDING A COMPLETE AND OPERA11ONAL v x U) w BUILDING WHETHER INDICATED ON THE PLANS OR NOT. w ° 0 Lu 0 0 ne r LL a a o ENGINEER SEAL ,III111111UJIJJ E MQ�QO�`�. yr . No. 6098cc STATE OF 41 .r Rj°�E�'AB PLUMBING DRAWING INDEX �JJ j AL I dB�tV ;D`e�}' SHEET DESCRIPTION ISSUED Eric J. Svob PE P.E. No. 6090982 P-I PLUMBING LEGEND, NOTES, SCHEDULES 6 DETAILS YES MSE O"CCIFMS, N VEIN TE C@ UTS RR" m RE w PRESENTED IErdTI P& MIQIDEO "iY RN 111E SKCFX � T � N P-2 PLUMBING PLAN YES NM RWu Rnaac"Ts snort VMn umE"ovn " ;;�'�,""M, � �,,,;" m P-3 PLUMBING WASTE -VENT RISER YES W PD:RCE ERE,DIDtAG, D PLC mws RESERVER SHEET TITLE P-4 PLUMBING WATER RISER YES PLUMBING LEGEND, NOTES, SCHEDULES & DETAILS ISSUE DATE: 11-28-2018 DRAWN: EJS APPROVED: EJS DRAWING NUMBER P - 1 NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. SHEET I OF 4 17001-15 K 0 4N W UTIu' Ilk FLU�ISING FL/LA UJ;4,STF- VENT _ SCALE 1/8" = I'-O" Ilk PLUMBf NC; FLAN - UU,4TER - SCALE 1/8" = 1'-0" 2' WATER. SEE SITE 1I M Ity DI AKI GENERAL NOTES: I. FIELD VERIFY WASTE TIE-IN INVERT ELEVATION PRIOR TO ROUTING WASTE LINES. 2. ROUTE WATER LINES ABOVE CEILING AS INDICATED. KEY NOTES: 0 2' VENT THRU ROOF. 2O 3" VENT THRU ROOF. 0 ROUTE 2N WATER UP ABOVE CEILING. ® PROVIDE VALVE BOX FOR REF. WATER CONNECTION. W .. C1� Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 a 0 U j ao U w au U U Q w W w 0- 0 W O O V J CC) u ro U a W 0 Z Q M QIJi O z o w ~ U F_ w �i w d W ULLJ O O O 0 f- Of W d ITO ENGINEER SEAL is Eric J. Svoboda, PE P.E. No. 60982 R &E BBCLIEATS WnUff YWTIER AIRI TM" WTAUM BY MU ?Q ENRBFERW INC, ewi W Vf11d1T "ILITY M i S CPY WTOM7, RCRT PIERCE E716BFFR ' x ALL wws RESERVER I SHEET TITLE I PLUMBING FLOOR PLAN I„--- ----; 11-28-2018 1 DRAWN: EJS APPROVED: EJS I DRAWING NUMBER I SHEET 2 OF 4 17001-15 a Q Y U Z" /I /I / I Vf 3tl VTR tl T? Imo?" Ztl P 112 <� tl i 3tl Ii 02 11/ktl � Si, II � 3tl ti�l� 2\ �L 2 j I I"11 L.2 ME Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 a 0 U j 7- a0 LL w Lr . z aw U O Q W wa 0 0 w a O m J ¢ 0 0 'T U CO L M Q W rn O o < O) O) M Q Z i U 0O �NLei W O W U O _J F U o a U) w 3 o o It LJ U Lr w L 0 u- I ENGINEER SEAL I Eric J. Svobodo, PE P.E. No. 60982 I SHEET TITLE I PLUMBING WASTE -VENT RISER ISSUE DATE: 11-28-2018 1 DRAWN: EJS APPROVED: EJS I DRAWING NUMBER I l 100 IC!�) I SHEET 3 OF 4 1 17001-15 ELECTRICAL SYMBOL LEGEND SPECIFICATIONS: a I. THE TOTAL ELECTRICAL INSTALLATION MUST MEET THE REQUIREMENTS OF THE COPY TO THE OWNER AND TO THE CONTRACTOR AND RETURN THE ORIGINAL FIELD BASIC MATERIALS BASIC MATERIALS CONT. FIRE ALARM/DETECTION SYSTEM TELEPHONE/DATA SYSTEM CURRENT EDITION OF THE FLORIDA ADMINISTRATIVE CODE (FAC), SECTION 611315-33, MARKUP TO THE CONTRACTOR. o o AND, BY REFERENCE IN THE FAC, THE FLORIDA BUILDING CODE, 6TH EDITION, 35. PER FBC C405.r.4.2, WITHIN 30 DAYS OF ELECTRICAL SYSTEM ACCEPTANCE BY THE (2017), THE FLORIDA FIRE PREVENTION CODE, 6TH EDITION, (2017), AND THE 2014 AHJ, THE CONTRACTOR SHALL PROVIDE THE BUILDING OWNER AN OPERATING AND SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION 2. EDITION Of NFPA 70, THE NATIONAL ELECTRICAL CODE. THE TOTAL FIRE ALARM AND DETECTION SYSTEM INSTALLATION MUST MEET THE REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA ADMINISTRATIVE CODE, MAINTENANCE MANUAL FOR ALL ELECTRICAL SYSTEMS INSTALLED IN ACCORDANCE WITH THESE PLANS THAT REQUIRE MAINTENANCE. AT A MINIMUM, THE MANUAL SHALL INCLUDE: 0 U w Sa SINGLE POLE SWITCH ® AUTOMATIC TRANSFER SWITCH MANUAL PULL STATION PHONE/DATA OUTLETS MOUNTED AT RECEPTACLE (SUBSCRIPT INDICATES ITEM CONTROLLED) NON -FUSED DISCONNECT SWITCH, AMP RATING / # OF POLES CEILING SMOKE DETECTOR, PHOTOELECTRIC HEIGHT UNLESS OTHERWISE NOTED. C = ABOVE THE COUNTER THE CODES INCORPORATED BY REFERENCE IN THE SECTION 61HE A. EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT U) z z S 3 THREE-WAY SWITCH NEMA I IF INDOORS TYPE UNLESS OTHERWISE NOTED M =NUMBER OF DATA PORTS, DEFAULT = I 2013 E OF NFA FAC, AND THE 2013 EDITION OF NFPA 72, THE NATIONAL FIRE ALARM AND REQUIRING MAINTENANCE. 0 S4 FOUR-WAY SWITCH NEMA 3R IF OUTDOORS N =NUMBER OF PHONE PORTS, DEFAULT = I SIGNALING CODE (EXCEPT AUDIBLE NOTIFICATION SHALL NOT EXCEED IIOdBI. N E =ELEVATOR WITH RECALL CONTACTS 3. ON ALL ELECTRICAL PLAN SHEETS, E.G. "E-I', 'E-2.1', ETC., THE TERM B. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF tr o Sp SINGLE POLE SWITCH WITH PILOT LIGHT FUSED DISCONNECT I = IONIZATION M DATA OUTLET, 8P8C 'CONTRACTOR' SHALL MEAN "ELECTRICAL CONTRACTOR', SOMETIMES ALSO EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE N SWP SINGLE POLE SWITCH WITH WEATHERPROOF COVER [�J.1 30AR AR DENOTES AMP RATING OF SWITCH 20AF ABBREVIATED AS 'E.C.'. ACTIONS SHALL BE CLEARLY IDENTIFIED. AF DENOTES AMP FUSE SIZE DUCT SMOKE DETECTOR N PHONE OUTLET, RJ II 4. MATERIALS AND EQUIPMENT INSTALLED SHALL BE ENTIRELY NEW, UNLESS z SWgT SPRING WOUND WALL SWITCH TIMER (30 MIN.) MCP •DENOTES FUSE PER MANUFACTURER RECOMMENDATIONS R =RETURN OTHERWISE NOTED, AND SHALL MEET U.L. REQUIREMENTS. C. NAME AND ADDRESS OF AT LEAST ONE QUALIFIED SERVICE AGENCY. SK SINGLE POLE KEY SWITCH SIZE # OF POLES S = SUPPLY M N COMBINED DATA/PHONE OUTLET, 8P8C/RJII 5. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. 36. WORKMANSHIP, w S3K ® SUPERVISED CONTROL RELAY MATERIALS AND APPARATUS UNDER THIS CONTRACT SHALL BE THREE-WAY KEY SWITCH yJ 30/3 3R COMBINATION MAGNETIC MOTOR STARTER, SIZE 8 # OF POLES 6. CONTRACTOR TO REMOVE AND INSTALL ELECTRICAL EQUIPMENT IN ACCORDANCE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL 0 S4K FOUR-WAY KEY SWITCH 0 3 POLE UNLESS OTHERWISE NOTED DUCT SMOKE REMOTE ALARM INDICATING LAMP, ® TELEPHONE OUTLET FLOOR MOUNTED WITH THESE PLANS, FROM THE EXISTING PANEL 'DP' TO AND THROUGH THE ACCEPTANCE BY THE OWNER. to Sp SINGLE POLE SWITCH WITH SECURITY LOCKING KEY ENCLOSURE NEMA RATING. R SWITCH, BRANCH -CIRCUIT PANELS TO AND INCLUDING ALL OUTLETS, DEVICES AND 37. GREATER THAN 80% NONLINEAR LOADS: SHARED NEUTRALS AND GROUNDS ARE NEMA STARTER SIZE W/ TEST WALL MOUNTED 72" AFF EQUIPMENT FURNISHED BY OTHERS AS MAY BE REQUIRED. NOT PERMITTED FOR SINGLE PHASE CIRCUITS. SLV LOW VOLTAGE SWITCH TTB 7. CONTRACTOR SHALL MAKE EARLY CONTACT AND MAINTAIN DIRECT COMMUNICATION 38. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE of S p CEILING FAN/LIGHT CONTROL, DAN'S FAN CITY #423LW OR EQUAL - � BRANCH CIRCUIT PANEL BOARD, UNDER 250 VOLTS, REMOTE INDICATING LAMP FIRE ALARM WITH TEST SWITCH ® TELEPHONE/COMPUTER TERMINAL BOARD WITH THE SERVING ELECTRIC UTILITY TO ASSIST THE OWNER IN OBTAINING A FAULT WITH NEC IIO, AND WITH NEC 210.8 FOR GFCI DEVICES. WHITE COLOR SURFACE MOUNTED WALL MOUNTED 72" AFF, SIMPLEX 4098-9642 OR EQUAL CURRENT LETTER, TO COORDINATE ANY OUTAGE FOR THE INSTALLATION OF NEW 39. THE EXCLUSIVELY -DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL w SM MOTOR RATED SNAP SWITCH, IHP MIN., 20A, 120/277V BRANCH CIRCUIT PANEL BOARD, UNDER 250 VOLTS, TTC FEEDER BREAKERS IN PANEL 'DP", AND TO ENSURE THE TIMELY PROVISION OF CEILING WITH A WIDTH AND DEPTH OF THE PANEL BOARD OR SWITCHBOARD MUST o LEVITON 1121-2 OR EQUAL �- - FLUSH MOUNTED COMBINATION AUDIBLE/VISUAL r� TELEPHONE TERMINAL CABINET ELECTRIC SERVICE. BE CLEAR Of ALL PIPING, DUCTS OR EQUIPMENT FOREIGN TO THE ELECTRICAL m SMp MANUAL MOTOR STARTER WITH OVERLOAD HEATERS AND PILOT LIGHT BRANCH CIRCUIT PANEL BOARD, OVER 250 VOLTS, - XXCD NOTIFICATION DEVICE CD = CANDELA RATING, MINIMUM 75 CD PER T ----,,TELEPHONE \TELEPHONE SYSTEM RACEWAY 8. SERVICE EQUIPMENT SHALL BE MARKED WITH THE MAXIMUM AVAILABLE FAULT CURRENT MCA") PER NEC 110.24 AND THE DATE OF THE MARKING. SEE RISER EQUIPMENT OR ARCHITECTURAL APPURTENANCES IN ACCORDANCE WITH NEC 408. 40. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE -RESISTIVE ASSEMBLIES, _ a Sp DIMMER SWITCH SURFACE MOUNTED FBC II-4.28.3(4) DIAGRAM SHEET E-4 FOR FAULT CURRENT CALCULATIONS. (CLASSIFIED AS FIRE/SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED z Fort P10T'Ce (1500 WATTS UNLESS OTHERWISE INDICATED) - BRANCH CIRCUIT PANEL BOARD, OVER 250 VOLTS, SS FIRE ALARM SPEAKER -CEILING MOUNTED O 9. CONTRACTOR TO COMPLETE ALL WORK INCIDENTAL TO MECHANICAL TRADES FOR A WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING FLUSH MOUNTED TELEVISION RACEWAY SYSTEM COMPLETE INSTALLATION, INCLUDING CONTROL WIRING, MOTOR STARTERS, CONDITIONS SHALL BE MET PER FBC 302: Engineering, Inc. STD SINGLE POLE SWITCH - TIME DELAY FOR EXHAUST FAN/LIGHTS DISCONNECT SWITCHES AND EQUIPMENT GROUNDS. A. ALL ELECTRICAL BOXES SHALL BE METALLIC. BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN WALL. $ WALL MOUNTED SPEAKER WITH STROBE 10. DEFERRED SUBMITTALS FOR SITE LIGHTING, FIRE ALARM AND OTHER LOW VOLTAGE Dependable Mechanical, Electrical (� DUPLEX RECEPTACLE, 5-20R UNLESS OTHERWISE NOTED CONDUIT SHALL INCLUDE PHASE, NEUTRAL AND GROUND CONDUCTORS XXCD CD =CANDELA RATING BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE. & Plumbing Design C.A. No.28173 SINGLE 5-20R RECEPTACLE, T DENOTES TWIST -LOCK ,,,-----,,,CONDUIT REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED). OTV TELEVISION OUTLET FOR ANTENNA PRIOR TO INSTALLATION. CONTRACTOR TOMAKENECESSARY PROVISIONS FORTHEB. � BRANCH CIRCUIT CONDUIT CONCEALED IN SLAB, S{�S FIRE ALARM SPEAKER -WALL MOUNTED TV TELEVISION SIGNAL WALL OUTLET INSTALLATION OF ANY AND ALL SYSTEMS FOR THIS PROJECT, INCLUDING RACEWAYS, CABINETS, PULL BOXES AND OUTLETS. SEE SHOP DRAWINGS FOR EACH SYSTEM C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES. SURGE PROTECTION TYPE (TVSS) UNDERGROUND OR UNDER FLOOR. FOR ADDITIONAL DETAILS AND INSTRUCTIONS. SP DUPLEX RECEPTACLE ---� ATV -ATV DISTRIBUTION SYSTEM RACEWAY 11. CONTRACTOR SHALL FURNISH AND INSTALL ALL FIXTURES COMPLETE AS LISTED IN D. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED BRANCH CIRCUIT CONDUIT EXPOSED O FIRE ALARM SPEAKER WITH STROBE - CEILING MOUNTED THE "LIGHTING FIXTURE SCHEDULE". 1/8 INCH BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE ® PEDESTAL MOUNTED RECEPTACLE i� GROUND OR GROUND ROD AS NOTED CD = CANDELA RATING ❑M MAGNETIC LOCK 12. PANELBOARDS, SWITCHBOARDS AND DISCONNECT SWITCHES SHALL HAVE COPPER OR OPENING. ® FLOOR OUTLET BOX AND DUPLEX RECEPTACLE f EMS EMERGENCY BRANCH CONDUIT VISUAL SIGNALING UNIT, WALL MOUNTED CCTV CAMERA W/ CONDUIT TO VIDEO 13. COPPER (NOMINAL 15% BY VOLUME) CLAD ALUMINUM BUS. ALL PANELS, DISCONNECTS, TIME CLOCKS, AND CONTACTORS SHALL BE LABELED E. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE WITH APPROPRIATE FLANGE. (NO AUDIO DEVICE) JUNCTION BOX WITH A PERMANENT ENGRAVED LABEL. IDENTIFICATION ON THE LABEL MUST COMPLETELY FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL). ® FLOOR OUTLET BOX WITH DUPLEX RECEPTACLE AND ONE COMBINATION W/ VOICE/DATA OUTLET -SNP CONDUIT TURNING UP fl FIREMAN'S PHONE JACK PTZ PAN/ TILT/ ZOOM CCTV CAMERA W/CONDUIT 14. CONFORM TO THESE ELECTRICAL DRAWINGS. TYPEWRITTEN CIRCUIT IDENTIFICATION SHALL BE INSTALLED IN ALL PANELBOARDS, F. PROVIDE A WALL AROUND OUTLETS LARGER THAN 16 SQUARE INCHES. THE DN CONDUIT TURNING DOWN SPRINKLER TAMPER TO VIDEO JUNCTION BOX - MOUNTED MIN 15' EACH BREAKER HAVING A DISTINCTIVE DESCRIPTION COMPLYING WITH NEC 408.4. IF INTEGRITY OF THE WALL RATING SHALL BE MAINTAINED. ® FLOOR OUTLET BOX WITH TWO DUPLEX RECEPTACLES ® SWITCH CONNECTION AFF OR o CEILING PRESENT, THE FIRE ALARM CONTROL UNIT BREAKER AND ITS DESCRIPTION SHALL AND ONE COMBINATION W/ VOICE/DATA OUTLET CONDUIT STUB 15. HAVE A CLEARLY VISIBLE RED MARKING. CONDUIT FOR UNDERGROUND SHALL BE SCHEDULE 40 PVC OR MC CABLE LISTED G. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 315 South 7th Street SYNCHRONOUS MASTER CLOCK SYSTEM IV POKE THRU -2 CONDUIT CONTINUED FS SPRINKLER WATER FLOW SWITCH CONNECTION FOR UNDERGROUND USE UNLESS OTHERWISE SHOWN AND/OR REQUIRED BY CODE. SQUARE INCHES PER 100 SQUARE FEET OF WALL AREA. Fort Pierce, FL. 34950 Phone: 772 672-4636 POWER POLE UNDERGROUND CONDUITS SHALL BE INSTALLED AT A DEPTH IN ACCORDANCE WITH Fax:772672-4637 gp SINGLE POLE SWITCH/RECEPTACLE COMBINATION -.�. FLEXIBLE CONDUIT FP FIRE ALARM SYSTEM PRINTER TABLE 300.5. H. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE -RESISTIVE ASSEMBLIES S 16. CONDUIT FOR ABOVE GRADE SHALL BE 'GRC', 'IMC' 'SCH 80 PVC' OR "EMT". SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. DUPLEX RECEPTACLE WITH EACH HALF ON SEPARATE CIRCUIT EXISTING TO BE REMOVED ZONE ADDRESSABLE MODULE SYNCHRONOUS SYSTEM CLOCK "LFNC" SHALL BE USED FOR CONNECTIONS TO AIR HANDLING UNITS, CONDENSING (BREAKER SHALL BE TWO POLE WITH COMMON TRIP) _ EXISTING TO REMAIN UNITS, WATER HEATERS AND OTHER EQUIPMENT. MC CABLE MAY BE USED FROM I. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS. DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER EXISTING AFFECTED BY THIS PROJECT ® ELECTROMAGNETIC DOOR HOLD OPEN DEVICE FFAATTC MASTER CLOCK CONTROL PANEL "J-BOXES' IN CEILING TO SWITCHES, RECEPTACLES AND BETWEEN DEVICES. SPARE CONDUITS SHALL HAVE A PULL WIRE INSTALLED. CONDUIT OR CABLE FOR BRANCH DUPLEX TAMPER -RESISTANT RECEPTACLE. MOUNT - FUTURE ® H ELECTROMAGNETIC DOOR HOLD OPEN DEVICE CONNECTION TO CLOSURE/ HOLDER CL MASTER CLOCK SYSTEM CONDUIT AND WIRING CIRCUITS IN PATIENT CARE AREAS SHALL BE IDENTIFIED AS AN EQUIPMENT GROUNDING CONDUCTOR. COVER PLATE WITH SPANNER HEAD SCREWS 17. CONDUCTORS SHALL BE THHN/THWN EXCEPT WHERE SPECIFIED OTHERWISE ON THE DUPLEX RECEPTACLE WITH TOP HALF SWITCHED NEW ELECTROMAGNETIC DOOR HOLD OPEN DEVICE DRAWINGS. CONDUCTORS NO. 8 AWG AND LARGER SHALL BE JOINED BY AN H CONNECTION TO CLOSURE/ HOLDER INCLUDES DETECTOR DOORBELL SYSTEM APPROVED PRESSURE CONNECTOR. CONNECTION TO GROUND CONDUCTORS NO. 1/0 AWG AND LARGER SHALL BE CAST BY FUSIBLE METAL PROCESS. ALL CONDUCTORS 0 GFI RECEPTACLE (EWC DENOTES ELECTRIC LIGHTING WATER COOLER. COORDINATE WITH EWC CEILING HEAT DETECTOR 135 F UNLESS OTHERWISE MUST BE INSTALLED IN CONDUIT, MC CABLE, OR LFNC. CONDUCTORS IN PANELS > 0 EWC INSTALLER FOR MOUNTING HEIGHT) OH INDICATED. SHALL HAVE THEIR FACTORY LABELS VISIBLE TO A PERSON IN THE WORKING a GFI RECEPTACLE. WP DENOTES WEATHERPROOF COVER. F-0- 11 FLUORESCENT STRIP FIXTURE - DOOR PUSH-BUTTON STATION 18. SPACE. CONDUCTORS OF MULTIWIRE CIRCUITS SHALL BE GROUPED IN AT LEAST ONE w w tr z a td WPC FIXTURE-yA FLUORESCENT FIXTURE BEAM DETECTOR TRANSMITTER WP = WEATHERPROOF LOCATION WITHIN THE PANELBOARD OR OTHER POINT OF ORIGIN BY WIRE TIES OR a w GFI RECEPTACLE MOUNTED ABOVE COUNTER DESIGNATION M4 BEAM DETECTOR - RECEIVER pg DOORBELL CHIME (SELF CONTAINED) SIMILAR MEANS. MULTIWIRE CIRCUIT DISCONNECTS SHALL BE PROVIDED WITH A w w a � 0 0 CIRCUIT-�-2 a- LOWER CASE LETTER INDICATES CONTROL CIRCUIT SWITCH LEG MEANS TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT THE z - to TWO DUPLEX RECEPTACLES WITH COMMON COVER NUMBER � FLUORESCENT FIXTURE FACP o FIRE ALARM CONTROL PANEL pg -\DOORBELL SYSTEM CONDUIT AND WIRING 19. POINT WHERE THE BRANCH CIRCUIT ORIGINATES. NO CONDUCTORS SMALLER THAN 12 AWG SHALL BE USED FOR POWER AND w U 0 0 rn w �d 00 0 m 0 ILL TWO DUPLEX RECEPTACLES WITH COMMON COVER DIAGONAL SHADING DENOTES EMERGENCY LIGHT FIXTURE. FATC LIGHTING. ALL CONDUCTORS SHALL BE COPPER, UNLESS NOTED OTHERWISE. MOUNTED ABOVE COUNTER � FLUORESCENT WRAP AROUND OR SURFACE MOUNTED FIXTURE. o FIRE ALARM TERMINAL CABINET 20. COLOR CODE FOR 208Y/120V 3e SYSTEM SHALL BE: BLACK, RED, BLUE, WHITE, a GREEN. ISOLATED GROUND DUPLEX RECEPTACLE, (ORANGE 4 FLUORESCENT WALL MOUNTED FIXTURE WITH WALL OUTLET BOX FRP FIRE ALARM ANNUNCIATOR PANEL - FLUSH MOUNTED DOOR CONTROL SYSTEM 21. CONTRACTOR SHALL VERIFY WITH ARCHITECT FOR DETAILED DIMENSIONS AND IG DEVICE) -�_ LOCATIONS OF OUTLETS AND EQUIPMENT AND FOR ANY REVISIONS IN LAYOUT. DUPLEX RECEPTACLE HID, INCANDESCENT OR FLUORESCENT WALL MOUNTED FIXTURE 22. MOUNT WALL SWITCHES 44' ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON NOTE: 0 HID, FLUORESCENT, OR INCANDESCENT FIXTURE ,--F--_.FIRE FIRE ALARM SYSTEM CONDUIT AND WIRING DRAWING. GANG SWITCHES WHEREVER POSSIBLE. TICK MARKS SHOWN ON ANY DEVICE REPRESENTS RECEPTACLE MOTION DETECTOR 360 SWITCHES SHALL BE ROCKER TYPE, 120 VOLT, 20A, COMMERCIAL SPECIFICATION GRADE, UNLESS OTHERWISE NOTED. SWITCHES SHALL BE WHITE IN COLOR. ELECTRICAL ABBREVIATIONS CONNECTED TO THE EMERGENCY CIRCUIT (RED DEVICE) TYPICAL FLUORESCENT, OR INCANDESCENT WALL WASHER. �E FIREMAN'S ELEVATOR WARNING LIGHT CR SWITCHES CONTROLLING LINE -TO -NEUTRAL LIGHTING LOADS SHALL COMPLY WITH FOR ANY DEVICE IN LEGEND �- ACCENT FLOOD LIGHTING - AIMING AS INDICATED KR KNOX BOX -LOCATION TO BE COORDINATED WITH THE AHJ CARD READER NEC 404.2(C). AFF: ABOVE FINISHED FLOOR L: LIGHTING LOAD 0 © CLOCK RECEPTACLE EXIT LIGHT FIXTURE K❑ DIGITAL KEYPAD 24. RECEPTACLES SHALL BE LOCATED 15' ABOVE FINISHED FLOOR TO CENTER LINE OF AFG: ABOVE FINISHED GRADE M: MOTOR LOAD Z mDEVICE, ® SPECIAL PURPOSE RECEPTACLE, RATING AS NOTED ® DIRECTION ARROWS AS SHOWN PAGING SYSTEM & BACKGROUND MUSIC U BALANCED MAGNETIC DOOR CONTACT UNLESS OTHERWISE NOTED. ABOVE -COUNTER RECEPTACLES SHALL BE MOUNTED 6 ABOVE BACK SPLASH TO CENTERLINE OF DEVICE. BFC: BELOW FINISHED CEILING MBJ: MAIN BONDING JUMPER E.C.: ELECTRICAL CONTRACTOR NL: NIGHT LIGHT w g O z 'a � o 30 (SHADED QUADRANT INDICATES FACES) OF FIXTURE) 25. COVER PLATES SHALL BE WHITE PLASTIC, UNLESS OTHERWISE NOTED. EGC: EQUIPMENT GROUNDING CONDUCTOR P: PANEL Q _ _j a LIGHTING CONTROL TIME CLOCK ® WALL MOUNTED EXIT LIGHT FIXTURE RECEPTACLES WITH PLASTIC COVER PLATES SHALL BE MOUNTED SUCH THAT THE F: FAN LOAD R: RECEPTACLE LOAD z 04 L) w ® PHOTOCELL MOUNTED ON ROOF FACING NORTH Hj COMBINATION EXIT/EMERGENCY LIGHT FIXTURE LOUDSPEAKER/ TRANSFORMER/ BAFFLE/ INTERCOM SYSTEM GROUND PIN IS MOUNTED DOWN, UNLESS OTHERWISE NOTED. RECEPTACLES WITH FCA: FAULT CURRENT AMPERES SA: SMOKE/CO ALARM LOAD GC: GROUNDED CONDUCTOR SN: SOLID NEUTRAL _j w w METAL COVER PLATES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS 3 0 IG_Nfl GROUND BAR EXTERIOR LIGHT FIXTURE WITH ARMS AS SHOWN O-fl SUPPORT TRUSS. (CEILING MOUNTED) MOUNTED UP UNLESS OTHERWISE NOTED. GEC: GROUNDING ELECTRODE CONDUCTOR LION: UNLESS OTHERWISE NOTED 0 0 � ON DRAWINGS W = WALL MOUNTED 26. ALL NEW 125V RECEPTACLES SHALL BE NEMA 5-20R, COLOR SHALL BE WHITE. GFI: GROUND FAULT CIRCUIT -INTERRUPTER VP: VAPOR PROOF O tr o ® PLUG-IN STRIP WITH RECEPTACLES, 18 O.C. UNLESS PB ELECTRICAL PULL BOX IC MASTER STATION OUTDOOR RECEPTACLES SHALL BE WEATHER RESISTANT. IG: ISOLATED GROUND WP: WEATHER PROOF 0- a � OTHERWISE INDICATED S LOUDSPEAKER/ TRANSFORMER/ BAFFLE/ C =COUNTER 27. ALL DEVICES SHALL BE MOUNTED VERTICAL, UNLESS OTHERWISE NOTED. TRACK WITH TRACK LIGHT FIXTURE (TRIANGLES --V- ENCLOSURE FOR EXPOSED CEILING AREAS D = DESK 28. CONTRACTOR SHALL CONNECT AIR CONDITIONERS, PUMPS, FANS AND OTHER ELECTRICAL DRAWING INDEX ENGINEER SEAL ++++++++++,, ® UNDER GROUND CONCRETE ENCASED DUCTBANK INDICATE QUANTITY OF LIGHT FIXTURES) W = WALL MOUNTED W = WALL MOUNTED EQUIPMENT. JUNCTION BOX ® BATTERY PACK WITH TWIN HEADS (CEILING MOUNT) S� HORN/TRANSFORMER H = HAND SET TYPE 29. AIR CONDITIONER BREAKER SHALL BE MARKED 'LISTED HACR TYPE" AS REQUIRED ewe+�� Y C• r� BATTERY PACK WITH TWIN HEADS (WALL MOUNT) FOR HIGH NOISE AREAS HF =HANDS FREE BY NEC 110.3(B). IF BREAKER IS NOT MARKED, THE OUTSIDE DISCONNECT SHALL BE SHEET DESCRIPTION ISSUED �.� o • ceN rfi `� S''• IZ --m JUNCTION BOX- WALL MOUNTED WP =WEATHER PROOF CHANGED TO A FUSED DISCONNECT WITH RATING A5 NOTED ON A/C EQUIPMENT. JUNCTION BOX- FURNITURE SYSTEM FEED PAEC o PAGING SYSTEM EQUIPMENT CABINET IC INTERCOM SYSTEM SPEAKER 30. CONTRACTOR SHALL MAKE TESTS AND ADJUSTMENTS AS REQUIRED, UPON COMPLETION OF THE WORK AND BEFORE FINAL ACCEPTANCE BY THE OWNER. THE E-1.0 ELECTRICAL LEGEND, SPECIFICATIONS 8 ABBREVIATIONS YES No 8158Q; 2 MOTION/OCCUPANCY SENSOR SYSTEM ■ CONDUIT SEAL -OFF FITTINGS W = WALL MOUNTED CONTRACTOR SHALL TEST THE COMPLETE ELECTRICAL SYSTEM IN THE PRESENCE E-1.1 ELECTRICAL SITE PLAN YES O - PATC PAGING SYSTEM TERMINAL CABINET OF THE ENGINEER/ARCHITECT FOR CONTINUITY, FUNCTION, CONTROL, PERFORMANCE, ' 9 t STAT( OF , ttr: SP 3 SURGE PROTECTOR o ICEC LOAD BALANCE GROUNDS AND GROUND RESISTANCE SHORT CIRCUITS, AND TO E-1.2 ELECTRICAL SITE LIGHTING PLAN YES 000'=.� p ,• d 101 C3 =SERVICE ENTRANCE DEVICE, MAX 250KA PER PHASE LCP LIGHTING CONTROL PANEL r� INTERCOM EQUIPMENT CABINET INSURE SATISFACTORY OPERATION AND CONFORMANCE TO CONTRACT E-2 ELECTRICAL POWER SYSTEMS FLOOR PLAN YES r1 B3 = DISTRIBUTION BOARD DEVICE, SEE RISER FOR RATING DR DOCTORS REGISTRY SYSTEM CONDUIT AND WIRING REQUIREMENTS. A3 = PANEL BOARD DEVICE, MAX 125KA PER PHASE 31. EQUIPMENT, LABOR AND MATERIAL REQUIRED FOR TESTING SHALL BE FURNISHED E-3 ELECTRICAL LIGHTING SYSTEMS FLOOR PLAN YES qia►++�eeP�° ST SHUNT -TRIP BUTTON - FLUSH MOUNTED UNLESS © PASSIVE INFRARED OCCUPANCY SENSOR C = CEILING MOUNT ICTC o INTERCOM TERMINAL CABINET BY THE CONTRACTOR(S) AS PART OF THIS CONTRACT. E-4 ELECTRICAL DETAILS, RISERS, & SCHEDULES YES Timothy C. Trewwyyn, PE OTHERWISE NOTED NEMA 3R FOR EXTERIOR LOCATIONS W =WALL MOUNT VC VOLUME CONTROL 32. PRIOR TO COMPLETION OF THE WORK, THE CONTRACTOR SHALL MARK THE SERVICE E-5 ELECTRICAL LIGHTING CONTROL DETAILS YES P.E. No. 61580 EDH-X EQUIPMENT WITH THE AVAILABLE FAULT CURRENT PER NEC 110.24, USING EITHER 'E?\^ � ELECTRIC DUCT HEATER IC INTERCOM SYSTEM CONDUIT AND WIRING THE FAULT -CURRENT FROM THE UTILITY FAULT CURRENT LETTER, OR THE SHORT M m U RM � m mm woe vmi � cum wasrt s rxEs� rn aarw oarY M ue rre Balm ❑U ULTRASONIC OCCUPANCY SENSOR CIRCUIT CURRENT CALCULATION FROM THESE PLANS. IF PROVIDED WITH THE wM Wf v a MOTOR CONNECTION. C = CEILING MOUNT SSEC FAULT CURRENT LETTER, THIS ENGINEER WILL UPDATE THE CALCULATION TO � MBYFRT vwna X.ram^"^ m� "r mtt � a�maraac, X. swu x _ � SOUND SYSTEM EQUIPMENT CABINET OBTAIN THE FAULT CURRENT AT THE SERVICE ENTRANCE. tenon wsam , nc suc �rmwr®ani, Fmr WT "�E rHmrmu+�, BE � � resExvea ® VARIABLE FREQUENCY DRIVE D❑ PASSIVE INFRARED / ULTRASONIC OCCUPANCY SENSOR 33. AFTER COMPLETION OF THE WORK, THE CONTRACTOR SHALL SECURE CERTIFICATES SHEET TITLE SSTC OF FINAL INSPECTION AND APPROVAL FROM AUTHORITIES HAVING JURISDICTION ELECTRICAL FH_D1 ELECTRIC HAND DRYER C = CEILING MOUNT SOUND SYSTEM TERMINAL CABINET (AHJ), FDZI DIRECT DIGITAL CONTROL PANEL W = WALL MOUNT 34. PER FBC C405.7.4.1, WITHIN 30 DAYS OF ELECTRICAL SYSTEM ACCEPTANCE BY THE SMS SINGLE SWITCH - g -� SOUND AHJ, THE CONTRACTOR SHALL PROVIDE THE BUILDING OWNER WITH RECORD SYMBOL LEGEND, POLE PASSIVE INFRARED SYSTEM CONDUIT AND WIRING DRAWINGS OF THE ACTUAL INSTALLATION. THE RECORD DRAWINGS SHALL INCLUDE GENERAL NOTES & TRANSFORMER OCCUPANCY SENSOR A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND GFCI DEAD FRONT/BLANK FACED, WHITE GFCI DEVICE. FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. IF ABBREVIATIONS ISSUE DATE: 11-28-2018 EATON # SGFD20 W. MOUNTED AT 48" AFF OR EQUAL ® OCCUPANCY SENSOR POWER SUPPLY PROVIDED WITH COMPLETE FIELD MARKUPS ON THESE PLAN SHEETS, THE ENGINEER CONTROLLED RECEPTACLE. BREAK OUT TAB FOR SPLIT SHALL MODIFY THESE PLAN SHEETS INTO SAID RECORD DRAWINGS AND PROVIDE A C OPERATION. SHALL BE MARKED IN FIELD PER 406.3(E). NOTE: DRAWN: TEC BOTTOM RECEPTACLE TO BE CONTROLLED VIA TIME CLOCK TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017) AND THE FLORIDA FIRE PREVENTION APPROVED: TCT CODE 6TH EDITION (2017). DRAWING NUMBER E-1 SHEET I OF 7 17001-15 i 1 i 1 i I I ° 1 041 d I0, I 1 I I 1 EXISTING UTII COP — C PAD MOUNODDIITRAN FOR ER IL EXISTING SE°jDARY SE ICET TO METER T� REMAI 1 FIELD LOCATE THE EXI N MODULAR UNFT$ UNDERGROUNb TEL/DATA CONDUITS. FURNISH AND INSTALL NEW CONDUITS F EXTENSION TO THE NEW DATA 1' ROOM, PULL BOX FOR ;THE EXTENSION OF THE CONDUIrS,I ETC FOR A COMPLETE' l RACEWAY SYSTEM �I I I 1 I i °I 1 i I 1 1 °I 1 1 I I PRIOR TO CAVA NG E CONTRAC IS TO VERIFY 1HE LOC EXISTING SERVICES Q OF WNDERGROUND HE ( I I1 I °I EXISTING CONDUIT BAN PRIMARY ELECTRIC SER TELEPHONE CONDUITS SECURITY CONDUITS II ° I ° I °I I °I ° I ° I ^e 1 EXISTING 2' CONDUIT W/ PULL MIRE STUBBED OUT BELOW GRADE FOR FUTURE F/A SYSTEM C----------- EXISTING 2' CONDUIT W/ PULL WIRE STUBBED OUT BELOW GRADE FOR FUTURE TELEPHONE SYSTEM d — 420 nP + ° 411 a ° ,r+ • J 7 _j- d Ur-_0_ — EXISTING METER ON PEDESTAL SA —EXISTING PANEL 'DP' MH:10 —EXISTING (6) FEEDERS (CONDUITS AND CONDUCTORS) TO THE MODULAR UNIT PANELS ARE TO BE DISCONNECTED SA AND REMOVED BACK TO PANEL •DP'. MH:10 \-FIELD LOCATE EXISTING TEL/DATA CONDUITS SA AH:10 EXISTING PANEL 'DP', FEEDER AND METER ARE TO REMAIN IN PLACE. THE ELECTRICAL CONTRACTOR IS PROVIDE PROTECTION OF THE ABOVE ITEMS DURING CONSTRUCTION. 10 DATA ROOM -REFER TO FLOOR =====8 PLAN FOR EXACT LOCATION. -(2)2' CONDUITS WITH PULL WIRE FOR THE TEL/DATA SERVICE. TURN UP SA 0 GAFF IN THE DATA ROOM MH:10 B BEN0[ PROPOSED STORY SET STORAGE/RECORDS BUILDING EL. 1 MAXIMUM BUILDING HEIGHT = 26-6" 10,725 SF FFE = 20.50 SA MH:10 (LB 6018) ) 88) a ° EXISTING CONCRETE SLAB (BASKETBALL) d d. d . d ° rING UTILITY COMPANY MOUNTED TRANSFORMER d ------------- A 9Q SA SA MH:10 MH:10 Ll UTILITY CNLA77 IIY � a SERVICE LA , ° :9Y 1�2 s 4 E EXISTING 1 STORY CBS BUILDING CRISIS STABILIZATION CENTER 36,077.72 SQUARE FEET F. F. E = 20,44' TELEPHONE _j BACKBOARD EXISTING LIGHT POLE (TYP.) ELECTRICAL 51TE FL,4N PROPOSED PHARMACY ADDITION 1,400 S.F. MATCH EXISTING FFE SCALE 1" = 20'-0" ° d ° d F EXISTING 1 STORY Elm CBS BUILDING DETOX CENTER 7,0%36 S.F. FFE = 2044' a ° d 101 a Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone:772 672-4636 Fax: 772 672-4637 a 0 U w tY Qo LULL 3 cw) w gwa 1- 0 O J 00LLM U 0 a o w a 0 o _j Q P _o 11 z o Ld 0 r U ~ x r w w U 3 a W 0 w O o o 0 Cr d a v ENGINEER SEAL 4%,111111eeeee"NY eC111 �TRI,,', � .�.......... C E S .' No 6158 STATE OF 0 R W n C?'�ee• 4�4S'QNAi i�r°ee Timothy C. Trewwyyn, PE P.E. No. 61580 RESE IDaApIS, ME�G VRN RE y M THE Ila aR ➢ES A PW3pRFD X CUE ME aw aLY iiR fi M PaEffi Ma nIDlf 6 fntf P8W£ FIGOERDL, .L M NWN IIET VFIE PAEPNaR. lEtlff at uP19ER RnNND. a R V VIIInR �RIPIEII MIIIp�Pi1R! MID ARNT,11ID1 RY N PEHE nGPIDWfi, VC W7, ai Vn1Y:R 4wEm RI iN: SNE �YAlaff Q3m"!, nRT PEAPE ♦7J➢✓EFARL. RL ALL WARS RESERVER SHEET TITLE ELECTRICAL SITE PLAN ISSUE DATE: 11-28-2018 DRAWN: TEC APPROVED: TCT DRAWING NUMBER 117 ®1o� SHEET 2 OF 7 17001-15 Luminaire Schedule Project: NEW HORIZONS WALKWAYS 07-05-2018 Symbol Qty Label Description Lumens/Lamp LLD LDD BF FLLFLum. Watts Total Watts D10 SA PHILIPS GARDCO 121-16L-530-NW-G3-3 WALL MOUNT 10' AFG N.A. 0,900 0.900 1.000 0.810 28.1 281 Calculation Summary Project: NEW HORIZONS WALKWAYS 07-05-2018 Label CalcType Units Avg Max Min Avg/Min Max/Min SIDEWALKS AND ENTRIES —Planar Illuminance Fc 2.15 3.7 0.8 2.69 4.63 ELECTRICAL SITE FHOTOMETRIC FLAN SCALE I" = 20'-O" Engineering, h Dependable Mechanical, Elec & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 3495( Phone:772 672-4636 Fax: 772 672-4637 Q U j a0 �U w 4 Q U a12� U J w wa F o 0 w O0V U J ob w fn Q r^ vl � M W O Q ro Q Ny O F- o_ LL z fX cai � uj O O U� O CJ x w 3 w a LJ 0 ui O 0 0 X 13� ow a v ENGINEER SEAL Timothy C. Trewyn, I P.E. No. 61580 nts malxxrs, xaa vnx nc cactus etao i %SSSNIEa Ba Man PA ]NI aLY fat ilE 3n ROM18ROMa' MT PIM nm�sc, irF'/ Vax PFfPIfSIl REUSE ai uPRp'[R R ww T TMII MS VIfIWf VFIW MRIQ�anM AOAPfRTRN RY Nn RIIif ENGRCWYM OIG M7 vnraa unR¢in m rrE sxc rBrRtarrmRaz R❑AE ENLMaNIG, we w. RVVRS nEaRvm. SHEET TITLE ELECTRICAL SITE PLAN LIGHTING ISSUE DATE: 11-28-2018 DRAWN: TEC APPROVED: TCT DRAWING NUMBEF E — 1 SHEET 3 OF 7 17001-15 FIRE ALARM NOTES: LIGHTING CONTROL LEGEND- a Y U I I I I I Iwl I0I POKER SYSTEMS FL,4N 01.-P-i L= I/ o = I —1.l FIRE ALARM DEVICES ARE SHOWN FOR PERMITTING PURPOSES ONLY. THIS DRAWING IS NOT INTENDED TO SHPW ALL ASPECTS OF THE FIRE ALARM SYSTEM. THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS ACCEPTABLE TO THE BUILDING DEPARTMENT AND FIRE MARSHALL AND SUBMIT THEM TO THE LOCAL AUTHORITY FOR PERMITTING. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A COMPLETE OPERATING SYSTEM ACCEPTABLE BY THE AUTHORITY HAVING JURISDICTION AT NO ADDITIONAL COST TO YHE OWNER. CHANGE ORDERS FOR ADDITIONAL REQUIRED DEVICES OR FIRE PANEL EXPANSION OR REPLACEMENT WILL NOT BE CONSIDERED ADDITIONAL SERVICES AND MUST BE INCLUDED IN THE ORIGINAL BID. TRANSFORMER TO PANEL DP VOLTAGE DROP = 1.73 X 12 X 295 A X 30 FT X 1 = 0.53 V / 208 = 3PH 4W 700000 FEEDER FROM PANEL DP TO PANEL P2 VOLTAGE DROP 1.73 X 12 X 145 A X 105 FT = 1.88 V / 208 = 3PH 4W 167800 TO AHU-1 IN HEAT MODE BRANCH CIRCUITTO AHU-31N HEAT MODE VOLTAGE DROP 1.73 X 12 X 49 A X 75 FT = 2.91 V / 208 = 1PH 2W 26240 TOTAL VOLTAGE DROP WATTSTOPPER # W-2000-H LOW VOLTAGE HALLWAY SENSOR WATTSTOPPER # BZ-250 20A POWER PACK WATTSTOPPER # LMDW-101 WALL MOUNTED DUAL TECH. OCCUPANCY SENSOR WATTSTOPPER # LMRC-101 SINGLE ZONE SWITCHING ROOM CONTROLLERS WATTSTOPPER # LMDW-102 WALL MOUNTED DUAL TECH. TWO -ZONE OCCUPANCY SENSOR WATTSTOPPER # LMRC-102 TWO ZONE SWITCHING ROOM CONTROLLER WATTSTOPPER # LMDC-100 CEILING MOUNT DUAL TECH. OCCUPANCY SENSOR WATTSTOPPER # LMSW-101 SINGLE BUTTON SWITCH WATTSTOPPER # LMSW-102 TWO BUTTON SWITCH WATTSTOPPER # DT-355 LINE VOLTAGE DUAL TECH. CEILING MOUNT OCCUPANCY SENSOR WATTSTOPPER #DSW-100 LINE VOLTAGE WALL MOUNT DUAL TECH. OCCUPANCY SENSOR WATTSTOPPER # LMPL-101 PLUG LOAD CONTROLLER. SWITCH LOWER HALF OF EACH INDICATED RECEPTACLE WEATHERPROOF DOOR BELL PUSH BUTTON ELEG 1 HIGAL KEY NOTES: �j EXHAUST FAN TO BE CONNECTED TO AND CONTROLLED VIA THE ROOM LIGHT SWITCH. E.C. TO PROVIDE TOGGLE DISCONNECT ABOVE CEILING FOR THE EXHAUST FAN. ❑2 COE= INDICATES DUPLEX RECEPTACLE THAT IS TO HAVE THE BOTTOM RECEPTACLE CONTROLLED VIA ROOM OCCUPANCY SENSORS. CONTROLLED RECEPTACLES TO BE LABEL RECEPTACLE WITH THIS SYMBOL O- 03 (2)2' TEL/DATA CONDUITS, TURNED UP 6' AFF, CAPPED AND BUSHED. REFER TO THE SITE PLAN FOR CONTINUATION. ® DATA OUTLETS TO HAVE (2) DATA PORTS. a ALL PHONE AND DATA CABLES TO BE CAT 6. ❑5 PROVIDE CONDUIT AND BOXES AS REQUIRED BETWEEN SPRINKLER SYSTEM WATER FLOW AND TAMPER SWITCHES, T1 H, AND THE FACU. SEE SPRINKLER SYSTEM SHOP DRAWINGS. z cn o F_ z U w D 0 � o Z U z 0 U Ld N Er z O w w o > r 0 0 w z a- n w F Tn w > Tn w o m 11111111 ENNEEMMO Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone:772 672-4636 Fax: 772 672-4637 a 0 w� ao w� 0 . z aw 0 3� a U J w wa H � O Ld O K m J OOa U O w m a _ ro m L�.I O 0 a Q N a o LL z w I— O 0 J U) U ~) Ldw 3 a Ld c O O O 0 lr Of O O EL d V � ENGINEER SEAL Timothy C. Trewyn, PE P.E. No. 61580 T1ESE mnnvns, uou m PE �Ts a of XSM RSSEtOE➢ N]IEIX KE OOQtDE➢ OILY nk M SPE c RIBOSE NIO n v W MT P E nIDE K, M RR VINYI 11EY VIIS RIIPRGf➢, AEUSE OR ➢P9PER FnIIILE a SHEET TITLE ELECTRICAL POWER SYSTEMS FLOOR PLAN ISSUE DATE: 11-28-2018 1 DRAWN: TEC APPROVED: TCT I DRAWING NUMBER I SHEET 4 OF 7 17001-15 INTERIOR LIGHTING POWER CALCULATIONS PER FBC C405.5 Room ROOM WATTAGE AREA (SQ. FT) ALLOWANCE (WATTS/SQ. FT) ALLOWANCE RECORDS 1300 2700 1.0 2700 OFFICE 1 164 155 1.1 171 OFFICE 3 164 155 1.1 171 OFFICE 5 164 155 1.1 171 OFFICE 6 164 155 1.1 171 OFFICE 7 164 155 1.1 171 OFFICE 9 164 155 1.1 171 OFFICE 10 164 155 1.1 171 OFFICE 2 218 270 1.1 297 OFFICE 8 216 314 1.0 314 OFFICE 4 270 322 1.0 322 COMPUTER LAB 216 320 1.0 320 RECEPTION 164 180 1.0 180 COPIER 72 100 1.0 100 OFFICE 11 164 155 1.1 171 OFFICE 12 164 155 1.1 171 OFFICE 13 164 155 1.1 171 MECH. ROOM -SOUTH 101 140 0.95 133 MECH. ROOM -NORTH 101 140 0.95 133 MAINTENANCE 820 1120 0.95 1064 JANITOR RM. 52 95 0.95 90 UNI-SEX -WEST 40 45 1.0 45 UNI-SEX -EAST 40 45 1.0 45 MIENS HC ROOM 40 44 1.0 44 MEN RM. 53 60 1.0 60 WOMEN RM. 53 60 1.0 60 WOMENS HC ROOM 40 44 1.0 44 WAITING 80 215 0.8 172 CORRIDOR 403 665 0.7 466 DATA 54 70 1.0 70 CLOSET 51 75 0.7 52 Total Connected 6024 Total Allowance 8416 THE TOTAL CONNECTED INTERIOR LIGHTING POWER IS NOT GREATER THAN THE INTERIOR LIGHTING POWER ALLOWANCE LIGHTING FIXTURE SCHEDULE MARK MANUFACTURER - PART NUMBER LAMPS VOLTS MOUNTING DESCRIPTION REMARKS NO TYPE WATTS A DAY BRITE - 2EVG 74L H835 4 D UNV I LED 1 82 1 120 CEILING 2X4 RECESSED LED TROFFER WITH CENTER BASKET. OPAL DIFFUSER BASKET 7100 LUMENS 5 YEAR LIMITED WARRANTY. B DAY BRITE - 2EVG 54L H835 4 D UNV I LED 54 120 CEILING 2X4 RECESSED LED TROFFER WITH CENTER BASKET. OPAL DIFFUSER BASKET 5400 LUMENS 5 YEAR LIMITED WARRANTY. C DAY BRITE - 2EVG 48L H835 4 D UNV I LED 36 120 CEILING 2X4 RECESSED LED TROFFER WITH CENTER BASKET. OPAL DIFFUSER BASKET 4800 LUMENS 5 YEAR LIMITED WARRANTY. D BEGHELLI- PEH-I 2 LED 1.5 120 CEILING/WALL 2 LAMP UL 97 V-0 PLASTIC EMERGENCY LIGHTING FIXTURE. MOUNT 8'-0' A.F.F. FOR WALL MOUNT. E BEGHELLI - ATX SA LG U - LED <=5 120 UNIVERSAL ALUMINUM FRAME LED EXIT FIXTURE WITH WHITE POWDER COAT FINISH AND GREEN LETTERS. MOUNT 8'-0' A.F.F. FOR WALL MOUNT. UNIVERSAL FACE N0. 8 MOUNTING. F BEGHELLI - XCL GU W RC BRZ R WP 4 LED 5 120 WALL COMBINATION 2 LAMP THERMOPLASTIC EMERGENCY LIGHTING/EXIT SIGN. W/(2) REMOTE HEADS. MOUNT 8'-0' A.F.F. FOR WALL MOUNT. 65 TO 85 DEG F. LEAD CALCIUM BATTERY. G DAY BRITE -2EVG 38L 835 2 D UNV I LED 31 120 CEILING 2X2 RECESSED LED TROFFER WITH CENTER BASKET. OPAL DIFFUSER BASKET 3800 LUMENS 5 YEAR LIMITED WARRANTY. H CONTECH-CMR2 6 35K C WHT I LED 15 120 CEILING LED SURFACE MOUNTED DISK, WHITE FINISH, 7.5' DIA. WET LOCATION LABEL 5 YEAR LIMITED WARRANTY. J H.E.WILLIAMS - VMH V L17/840 T3 DBZ CGL 2120 1 LED 16 120 WALL LED MINI WALL PACK, BRONZE FINISH, LUMENS 1700 K H.E.WILLIAMS - 75 4 L50/835 DRV 120 1 LED 44 120 CEILING 4'0' NARROW LED STRIP LIGHT WHITE FINISH 5500 LUMENS SO. ACRYLIC LeNS M H.E. WILLIAMS - WMA 2 L30/835 AF DRV 120 1 LED 40 120 WALL TO' LONG WALL MOUNTED LED FIXTURE, FROSTED ACRYLIC LENS WHITE FINISH N LIGHTOLIER - PR61) 10 N U 8 35 D CL WH I LED 10 120 CEILING 6' DIAMETER DOWNLIGHT, CLEAR REFLECTOR, WHITE TRIM 1000 LUMENS GENERAL LIGHTING FIXTURE SCHEDULE NOTES: I. VERIFY TYPE OF CEILING FOR EACH FIXTURE WITH ARCHITECTURAL REFLECTED CEILING PLANS AND PROVIDE FIXTURE TRIM AS REQUIRED. 2. VERIFY VOLTAGES PRIOR TO BID AND INSTALLATION OF FIXTURES. 3. PROPOSED ALTERNATE LIGHTING BIDS MUST INCLUDE THE FOLLOWING: A. COST SAVINGS TO OWNER. B. PHOTOMETRIC LAYOUT OF PROPOSED ALTERNATE LIGHTING FIXTURES. C. ABOVE INFORMATION MUST BE SUPPLIED TO THE ENGINEER (3) DAYS PRIOR TO BID. 4. ALL COMPACT FLUORESCENT DOWNLIGHTS SHALL USE ELECTRONIC BALLASTS, UNLESS OTHERWISE NOTED. 5. PROVIDE APPROVED FIRE RATED ENCLOSURES FOR ALL LIGHT FIXTURES LOCATED IN FIRE RATED CEILINGS. 6. FIXTURES IN AREAS WITHOUT CEILINGS OR IN THREADED RODS. FIXTURES SHALL BE MOUNTED MECHANICAL AND ELECTRICAL ROOMS SHALL BE MOUNTED WITH I 1/2"A 1/2' KINDORF CHANNEL SUPPORT 10'-O'A.F.F. UNLESS OTHERWISE NOTED. SUSPENDED FROM ROOF STRUCTURE WITH 7. ALL ACRYLIC LENSED FIXTURES SHALL HAVE A MINIMUM LENS THICKNESS OF .125 INCHES. 8. ALL SHEET STEEL USED IN FIXTURES ABOVE SHALL HAVE A PHOSPHATE LAYER APPLIED PRIOR TO PAINTING. TT 5 C C C C D ❑I c C C C xx__ � ❑a �b ❑° ❑b ❑0' P.' ❑b ❑a ❑b ❑a � C C C C I-- ❑ �j ❑b PI-8 PI-8 PI-8 PI-8 PI-8 PI-8 PI-8 PI-8 PI-8 ❑a ❑b -32 �2-32 �b P2-32 I 6 (TP) �'�0 P2-3P2-36 P2-36 M @ P2-32 P2-32 a t F-O--I �ab ° C C C C C C C C P2-32 Qj C C C P2-32 C P2-32 A b A ° A b ❑ ❑a ❑b ❑a ❑b ❑o ❑b ❑a ❑b �B (TYPJ ❑b ❑a ❑b ❑ P2-3366 P2-3366 P2�36 PI-8 PI-8 PI-8 PI-8 PI-8 PI-8 PI-8 PI-8 PI-8 p - - P2-32 1 ARC\ab �a b PANEL 'PI" ® F T P2-32 A A i ,.d�:a t A PANEL 'P2' � �"( b a A ❑C b PI-8 C AEG 1 �71 -. C C C C C C C PI-8❑ a PI-BLJb PI-8 bON P2,P2-36 a p�P2-36 P2-36 P2-36 ® L GGGG t7 ❑a ❑b ❑a ❑b ❑a ❑b ❑° P2-32 PI-8 PI-8 PI-8 PI-8 PI-8 PI-8 PI-8 H o Ma, A a A A h C C C C �_i ❑ ❑ b❑ G ❑ ❑ ❑ „J D P2-32 ' ❑�Q� ❑b ❑a ❑b PI-10 PI-10 PI-10 PI-10 PI-10 D �I s P-30 �I P2-36 P2-36 �P36 H PI-8 �--1 PI-B _. ,.; PI-8 PI-8 I ❑ QP2-32 0 I P2-30 $ I t -4~t � loi e 0 PI-31 N A� AI P2"36 A 2-361 ❑b ❑a ❑b A e B A IDI b� d� P2- IJ PI-8 PI-8 PI-8 _. ❑ PI a ❑bPI-10 PI-10 PI-10 wPI-10 PI-10 PI-10 I I �abab ;. P2-< C C C S to A 1 �; B PI-10 2 A PI-10 $ B� C. C ;.:> G K P2P2 30 �� I❑ �H ❑ ❑' �? C C C C C � � ° i® �° ❑ �° ❑b �° PI-10 PI-10 PI-10 ,a` PI-31 PI-8 PI-8 PI-8 ®all b BPIPI-IOJo ®E 132-30 P2-30 P2-30 P2-30 P2-30 ,6 .. G G G (TYP.1��D- G G a GG GG G ❑ a G E_ ab /� ❑ ❑ ❑ ❑ ❑ v D LJ �l LJ P❑ (TYP.)a D P❑ Ie� P1.-.31 PI- I PI-31 . : PI-31 PPPIII 33311I FFFfff���iii PI-31 PI-31..,„ ® P2-30 P2-30 b b P2-30 a b �a b '�" p ❑ L_J ❑ ❑ ❑ A ® A ® A ® C C C� A A ® A P2-30 P2-30 P2-30 P2-30 PI-10 l ai PIPI-1� I I PI-10 I PIPI-I�a PI-I=b PIPI-IO�a a PIPI-1� PI-10 lol 0-31 0PI-31 0 ❑ (�•) "' DR a b lol � ,: PI-10 C C C C C $ C C $ g Jp a b a b a A❑ A❑ A= ❑ ❑ ❑ ❑ ❑ PI-10 PI-10 PI-10 ❑b a �b A❑ P2-30 P2-30 P2-30 P2-30 P2-30 A❑ A� O OPI-31 PI-10 PI-10 PI-10 PI-10 I-10 PI-31 El PI-10 d e l .. .. t H ❑ 0 P2-35 P2-35 �> LIGHTING SYSTEMS PLAN �i SCALE 1/8" = I'-O" LIGHTING CONTROL LEGEND• WATTSTOPPER # W-2000-H LOW VOLTAGE HALLWAY SENSOR ® WATTSTOPPER # BZ-250 20A POWER PACK ® WATTSTOPPER # LMDW-101 WALL MOUNTED DUAL TECH. OCCUPANCY SENSOR lol WATTSTOPPER # LMRC-101 SINGLE ZONE SWITCHING ROOM CONTROLLERS ® WATTSTOPPER # LMDW-102 WALL MOUNTED DUAL TECH. TWO -ZONE OCCUPANCY SENSOR WATTSTOPPER # LMRC-102 TWO ZONE SWITCHING ROOM CONTROLLER WATTSTOPPER # LMDC-100 CEILING MOUNT DUAL TECH. OCCUPANCY SENSOR ® WATTSTOPPER # LMSW-101 SINGLE BUTTON SWITCH ® WATTSTOPPER # LMSW-102 TWO BUTTON SWITCH WATTSTOPPER # DT-355 LINE VOLTAGE DUAL TECH. CEILING MOUNT OCCUPANCY SENSOR Dsw WATTSTOPPER #DSW-100 LINE VOLTAGE WALL MOUNT DUAL TECH. OCCUPANCY SENSOR Mal WATTSTOPPER # LMPL-101 PLUG LOAD CONTROLLER. SWITCH LOWER HALF OF EACH m INDICATED RECEPTACLE ELECTRICAL KEY NOTES: IQ EXIT SIGNS AND EMERGENCY BATTERY UNITS TO BE CONNECTED TO THE LIGHTING BRANCH CIRCUIT IN THE AREA AHEAD OF THE LIGHTING CONTROLS. ❑2 REMOTE TWIN HEAD, LOW VOLTAGE, EMERGENCY FIXTURES POWERED VIA EXIT SIGN. z M O Z U w � 0 U) o U Z 3 0 w z O O w w clf w Et' F w O a z o w cn W > U) w o m Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 a .o U j ao U Lu LL a Lal U a ir U J w w z oov U Q m Li r 0 a rn w o a rfi Q a o LL z p' o w O J N� U F w w w U 3 a O o o ~ o 0 Z a v ENGINEER SEAL �O NY C, "\C E N S 9F/y��.� O 61580 12 13 STATE OF : 41v /ONA L'E��,`�� Timothy C. Treyw%n, PE P.E. No. 6150 n n¢ r vnwrt wnmL xmmvAmx xm wvrAmx ar nRr uc awa BE wuwr �ueam m nc n+[ tlPYAifNt �tID1, mm SHEET TITLE ELECTRICAL LIGHTING SYSTEMS PLAN IJJUG VHI[: 11-28-2018 DRAWN: TEC APPROVED: TCT I DRAWING NUMBER I SHEET 5 OF 7 17001-15 STUB ABOI'- ""' "'" ACOUSTICAL TILE CEILING 3/4' CONDUI ACCESSIBLE STUB ABOVE CE" ACOUSTICAL TILE CEILING 3/4 CON OUT x4"xl 1/2' DEEP I TH SINGLE GANG -ASTER RING FLOOR NOTE: FOR GYPSUM CEILING TYPES, ROUTE CONDUIT WITH PULL -STRING BACK TO POINT OF BUILDING TELEPHONE/DATA SERVICE EQUIPMENT. A DATAXOMM. STUB -UP DETAIL FOR DISTANCE SEE MANUFACTURER'S INSTRUCTIONS - AHU AIR FLOW SAMPLING TUBE 48" SHUT DOWN CONTACTOR -� \,-18/2 TSPI8/2 TS OR RELAY (FURNISHED (2) #12 BY CONTRACTOR) TO RTU CONTROLS DUCT DETECTOR HOUSING WITH - PHOTOELECTRIC SMOKE DETECTOR D I DUCT SMOKE DETECTOR DETAIL SCALE _ DEDICATED 120V CIRCUIT C I ih TWO DUPLEX RECEPTACLES WITH COMMON COVER. PROVIDE UNISTRUT WITH PROVIDE ALL CONDUIT STRAPS AT 8 A.F.F. WITH BUSHING AND FISHWIRE 1" PVC WITH 2" CONDUIT TOY (1)#6 GROUND WIRE TELEPHONE CO. B I TELEPHONE TERMINAL BOARD DETAIL EXISTING PRIMARY ELECTRICAL SERVICE COORDINATE WITH FPL EXISTING FPL TRANSFORMER 3PH 120/208 VOLT EXISTING EST. 150KVA, 3.66%IZ METER ENCLOSURE 0Fi EXISTING (2) 3" C WITH (3) 350MCM CU IN EACH EXISTING GROUND ROD AND GROUNDING ELECTRODE CONDUCTOR. SCALE (N.T.S. i C I ELECTRICAL RISER DIAGRAM _ EXTERIOR EXISTING (2) 3" C WITH (4) # 350MCM AND GRD. IN EACH 10707 FCA � TING -10 FT PANEL "DP" I120/208V 3PH 4W 600AMP M.C.B. 22KAIC EXISTING MODULAR UNIT PANEL FEEDERS ARE TO BE REMOVED. INTERIOR -110 FT QI USE 2/0 BARE CU TO CONNECT NEW METAL STRUCTURAL MEMBER TO EXISTING GROUND ROD OR METER ENCLOSURE GROUNDING ELECTRODE CONDUCTOR TERMINAL. PANEL: - DP EXISTING VOLTAGE: iBUStBREAKER 1201208V 3PH 4W LOCATION: EXTERIOR AIC ffATING.: 22KAIC122KAIC MOUNTING: FREE STANDING-NEMA 3R RATING - 600A_ -.- MAIN CONNECTION: M.C.B. FED FROM: FPL TRANSFORMER DEVICE FAMILY: -.. GENERAL ELECTRIC DESCRIPTION y0 k Y P COXMlC JKV.: A B G No..l No. LbHNFCiER NV� A B C -�ti P 2 �' , 100 DESCRIPTION SPARE-NOT€.5 160 2 D.00 �• i 2 0 00 �, SPARE -NOTE 5 u I 0.00 '� 3 4 0 00 SPACE ; 0.00 5 6 0.30 1 20 12 L•EXTERIOR WAIL FIXTURES -NOTES 4& 6 SPARENOTES 100' 2 0.00 _ 0.00' 7 9 8 10 _ 0(W 0.00 IIII INh 2 100 SPARE -NOTES SPARE Ib<4I 0100 i1r' IIIO ily 0.66 11 12 ii1 R.-0-0 'i 0,00 SPACE SPARE -NOTE 8 100 2 '.. 13 14 I'I 2 100 SPARE -NOTES III Vw:r 0.00 yi ., 15 _ 1$ IIII 0.00 t SPACE IIII ; 20A9 0.00 17 18 20 b 105 '1 0 +"^'s' 48:84 9 IIII '0:0D D.00 SPACE NEW PANEL"P1" 310 200 3 '''. 19 u 11.80 .. =`r• "�I 3 200 310 _NEW PANEL '1 NOTE4 NOTE4 310 I.:4' 20-51 "ii,, 21 22 24 26 310 3f0 ,.'i „:, 0.00 .... :: 19.90 '," Iyi lry 23 25 310 SPACE SPACE SPACE , „II��IIIII 0.00 Ip, 0.00 27 28 SPACE SPACE I' ",: :"7 1i I' II 29 30 1I00.. .SPADE SPACE SPACE 000 0 00 : 31 33 32 34 (L 1k. SPACE SPACE _ SPACE i1„I{I 0.0A 35 37 366 38 1 . Ot00 SPACE - SPACE. SPACE 0.00 I I' ^' SPACE Ib rV.,, 000 IIIII I' . � , 0.00 39 41 40 42 OAO U SPACE - -. SPACE SPACE WII IIIP�P° ... 20-19 20.51 19,90 TOTA! 40.75 18.80 12A0 114.25 TOTAL CONNECTED KVA SERVES CONNECTED LOAD -KVA DF CALCULATED DEMAND KVA _ LIGHTING 8.31 1.25 10:38 - -_ RECEPTACLES FIRST 10 KVA) 10.00 1 Moo _ RECEPTACLES (OVER 10 KVA 15.29 015 7.65 LARGEST MOTOR 3R�. 125 3.75 OTHER MOTORS - 8.65 1 865 EQUIPMENTIHEAT 65.50 1 65,50 KITCHEN EQUIPMENT 0.50 1 0.50 TOTAL DEMAND KVA 106.43 TOTAL AMPERAGE 295:41. NOTES: ___. ._.. _-.. .... ,,... .._-. -. 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO BIDDING AND INSTALLATION.. 2. PROVIDE TYPEWRITTEN DIRECTORY ON INSIDE OF PANEL. COVER. _- - 3. NON -COINCIDENT DEMAND CALCULATION BASED ON. HEATING MODE. 4. FURNISH & INSTALL NEW CIRCUIT BREAKER W EXISTING PANEL SPACES, A.I.C. RATING TO MATCH THE EXISTING CIRCUIT BREAKERS. 5. EXISTING CIRCUIT BREAKER TO BE LABELED AS SPARE, AFTER REMOVAL OF THE MODULAR TRAILER FEEDERS 6. CIRCUIT CONTROLLED VIA PHOTO CELL ON & 20A 1PST WEATHER TIGHT TIME CLOCK W1 ASTRONIMICAL DIAL & BATTERY BACK-UP OFF. _ MOUNT ADJACENT TO PANEL "DP" THREE PHASE SHORT CIRCUIT CURRENT CALCULATION 150KVA=TRANSFORMER SIZE TRANSFORMERTO PANEL DP (2 SETS 35OMCM, 30 FEET, PVC) _ 150000 VA 100 ISC 1.73 X 208V X'.. 3.66%IZ = 11376AMPS f _ 1.73 30' X 11376A 0.062 2 22,737 208V- -1 1 + 0.062 0.941 11376AMPS X 0.941 _ 10707AMPS USE MINIMUM 22KAIC RATED BREAKERS IN PANEL DP PANEL DP TO PANEL P2 (1 SET 3/0 CU, 105 FEET, PVC) _ 1,73 105' 10707A X X 0.672 1 13,923 208V 1 IVJ c = 0.598 1 + 0.672 10707AMPS X 0.598 6402AMPS USE MINIMUM 10KAIC RATED EQUIPMENT AT PANELS Pl AND P2 RISER DIAGRAM GENERAL NOTES: I. E.C. SHALL PROVIDE ARC FLASH HAZARD WARNING SIGNS PER NEC 110.16. 2. E.C. SHALL LEGIBLY FIELD MARK PANELBOARDS WITH THE DATE OF MARKING AND FAULT CURRENT AMPS (FCA) NOTED ON THE RISER DIAGRAM. 3. THE CONDUCTOR LENGTHS SHOWN ARE APPROXIMATE AND CONSERVATIVELY SHORT 6282 FCA 6402 FCA TO PROVIDE A MARGIN OF SAFETY IN THE PANEL PANEL CALCULATION OF FAULT CURRENTS. THE "PI' 'P2" E.C. SHALL MAKE HIS OWN MEASUREMENTS 200A 200A AND ESTIMATE OF THE CONDUCTOR LENGTH M.L.O. M.L.O. REQUIRED. CU (443/0 CU T(443/0 (0#6 GIRD. (146 GIRD. T IN 2 1/2" C IN 2 1/24 C SCALE _ PANEL: VOLTAGE: BUStBREAKER AIC RATING: ° 1201206V 3PH 4W -- 22KAt10KA -- -- ILOCATION: MOUNTING: MAIN CONNECTION: •'P1" SURFACE-NEMA i M.L.O, DATA ROOM FED FROM: DEVICE FAMILY: EXISTING PANEL "DP" EATON EZ PANEL OR EQUAL DESCRIPTION m P caRaeKvn c�°""R P Y DESCRIPTION o A 8 C Na. No. A B C ,. ��--- 'R-OFFICES I,2 ,2 12 20 7:. 1.28 r r a i. " 2 i -08 III II iiII I'�' rlhlr4 'III"'I I' 411 1,08 +'.ijll I��ri III II 1,08- nfi Illill i 20.. 92 R-OFFICES 5,6' _..._. __ - -. R-OFFICES 3,2 12 20 1 h rr 9 28 'u, 3 d 1 _ 20 12 R•OFfICE97$ - R-OFFICE 12 20 1 h'619. it a 108 5 6 1 20 12 R-OFFICES 11'I li 4A3 MII' 1,2 ICE 12 20 1 1.v08., 0.72 I; ,„':; 9 f0 1,3D tffi 120 R-OFFICE-OFFICE 9 20. 12 L-OFFICES-1OFRECEPTION R-RECOROS•N;S E,W WALLS 12 20 1 1 "'.. 0.54 1 11 12 .,, ,, . °Yh ill, 1 1 20 1 12 1 L•OFFICES 14.COMP. RM: Lk -RECORDS -WORK STATIONS 12.. 2k 1 1.08 1 2$ .I�� tl Ilw` 1 20 . 12 R-EXTERIOR,. HVAC & SVC CONV WATER HEATER 10 30 2 .V€f�I„bu A 2. 5 2 . .. " ::�.. .. 15 16 ,till i'I"I 126 IRA i 20. 12 R-COMPUTER IA&WIE WAILS _ 10 11, .b 2 25 17 "1 18 11 I"I' P " 0.72- 1 _. 20. 12 R-COMPUTER LAB-N. WALL HVAC-AHU•1 8 SD 3 $AO �La3o, 19 20 0-72 '� P 1 20 12 R-COMPUTER Lia8.6_WALL FAN-2HP S 2". 20 42_M-CDATA R SIEN RDOHTR-15KW, - . _- 24 '4,44 0.2 20_ 12 &. -DATAROOMM N WB SO 3 d. 3 60 $ _ HVAC HTR-15KWFAN-15HP e u 7 _ -- L-CORRIDOR,WAIY. 12 20 1 T OS3 .}L;a '�'32 2N II , t2,88 - i I 3 4 8 HVAC-CU_-2 -- -- - R COPIER -RECORDS 12 20 1 j 3d 8 MCA-24 RSCANNER-RECORDS Y2 20 1 p Sp 35 36 i - III 2.88 8 _ SPARE _-_ _ 20 1 0.00 u)�I'i "L38 b �I 1 20' SPARE SPACE I " 40 IIII II tl 000 I�" '' ck"r ?'; SPAGE SPACE • �. ' i "a OA0 $1 I 42 10�' IIII PACE 15.83>C 16.61_ 16.25 TOTAL 11.68 11 22 10,97 92.56 TOTAL CONNECTED KVA - SERVES CONNECTED LOAD KVA OF _ CALCULATED DEMAND -KVA 'LIGHTING 3.63 125. 4.54 RECEPTACLES (FIRST 10 KVA) 10.00 - _ 1 10.00 __. '- _..__. RECEPTACL�OVERIOKVA} 6.83 D.5.. 3A2 LARGESTMOTOR 100 _ 1� -._.. 3.75. OTHER MOTORS 2.84 1. 2.64. 34.50 - EQUIPMENTMEAT 34.50 1 1 KITCHEN EQUIPMENT _. _� 0.00 A'-1-- _. 0.00 TOTAL DEMAND KVA _ _ 59.84 TOTAL AMPERAGE _ 163,33 NOTES: 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO _ BIDDING AND INSTALLATION..-_. 2. PROVIDE TYPEWRITTEN DIRECTORY ON INSIDE OF PANEL COVER. _. 3. NON -COINCIDENT DEMAND. CALCULATION BASED ON HEATING MODE... PANEL. VOLTAGE 6USfBREAKOE AIC RATING RATING, 120l208V 3PH 4W 22KA(10KA. 200A LOCATION: MOUNTING' MAIN CONNECTION -- "P2" _.. SURFACE NEMA 1 1 M.L.O._ _ FEDFROM: _ DEVICE FAMILY - -- - DATA ROOM L EXISTING PANEL- DP EATON E2 PANEL OR EQUAL -_ DESCRIPTION " 9 € P P 2 DESCRIPTION A B* C No. 'Na HVAC-CU3 8 +IO 3 2.$7 „'L 14 U Va'I N'N 1 2 193 "; rII 193 ° "^'"I, III 30 10 HVAC-CU-4 _ MCA-24287 11 I 3 4 14 MCA18.6- __- - 8 287 - 5. 458 i" „II' _ SPACE -SPACE ':. 7 8 „u"b71 2 45 $ HVAC AHU_-9 .HVAC-CU-5 -- 8 4D 2 IfI Ir11 2.50 i+' C 0 10 8 HTR8KWFAN-.SHP MCA•24.1 8 rfircl fil'p - Z50 1112 4.92 „. 1'+I'I iM,b:;'_2. SPACE HVAC4HU3 8 50 3 5,88 I 3+ rp R�„„•i.. 5.88 I I IIN � "•. 5:$e 13 14 50 8 HVACAHU-5 HT R-I5KW, FAN-T.5HP ._ 8 g 15 17 18 18 L 492 mll"':i 20 9 . 12 HTR SKYII,-FA f AN-iNP R OFFICES 11 &12 R PURCHASING 12 20 1 1,0 ill"Pil 20 }. 1.08 rl 1 20 ' 12 R OFFICE$13 & 12 R-CONE. ROOM - R CONE. ROOM-CDUNIER. 12 92 20 20 1 1 r [„ r 09 .... ,, '. 036 - 23 - 24 �0.36 072 0.72 1 12 NCE EN WALLS - R-MAINTENCE EN WALLS R.CONF. ROOM-REFRIG: 12 20 -IIII" 1 0 50 9�"," ", 0 36 1::", ". - 25 27 28 28 II II 1 '.. 0 00 y-'. TM... 1 1 2d__12 20 R.MECH. ROOMS -- SPARE R-COPIER ROOM 12 20 1 - b f ib R-CCPIER ROOM 12 20 1 Ii IIII °III III 0 36 29 30 ' -, 1 19 _ 1 20 12 1 L PURCHASING COPIER JC TOIL RMS-, R-EWC. 'f2 1 0 37 1 II a 31 32 098 t 0 72 yL i 9 20 12 L GGNF. RMMECH. RM,TOIJ. RMS CiUi: 12 R RECEPTION ROOM R-TOILET ROOMS 12 20 1 0 72 II'' ", 33 34 L-EXTERIOR CANOPY & WALL LTS•NOTE 4 12 26 1 D DD 35 36 ., 1.40 _ 1 12 40FFK:ES 11 1213, MAINTENANCE SPARE 20 1 0 O0 ', s wj 97 38 000 _ 9 20 SPARE SPACE 39 4-0 13.85 -m - 12 07 0.00 4.30 67 83 SPACE -- -- -- SPACE TOTAL CONNECTED KVA SPACE 90 7D . 13.23 0 DO 12 87 41 42 - SERVES CONNECTED _TOTAL LOAD - KVA D - y CALCULATED REMAND -KVA LIGHTING 4.38 9:25- SA7' RECEPTACLES FIRST to KVA 8.46 ___.__ 1 _ -- &40 RECEPTACLES LOVER 10.KWkj 0:00 _ 0:5._ ...-... tkOD _ LARGEST MOTOR Z64. _ 1.25 _._ 3r30 _._ OTHER MOTORS 137 1 3,37 EQUIPMENTIHEAT 31;00._ 1 31.00. KITCHEN EQUIPMENT - -__ 0.50 . _. 1:. 0.50'. _ TOTAL DEMAND KVA 52.10; iTOTALAMPERAGE 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO _ BIDDING AND INSTALLATION. 2. PROVIDE TYPEWRITTEN DIRECTORY ON INSIDE OF PANEL COVER. 3. NON -COINCIDENT DEMAND, CALCULATION BASED ON HEATING MODE. - 4. CONTROLLED VIA IPST TIME CLOCK WI AS7RONMICAL DIAL AND BATTERY BAC,_.,T„ADJACENTTO,PANEL"P2" L ro H 0 a I rn Z) z Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No.28173 315 South 7th Street Fort Pierce, FL. 34950 Phone:772 672-4636 Fax: 772 672-4637 Q 1; > 4 ao LU U�+ 4 Q U UQ fr J W LO D_ Ld U U re m J 0. O O ' U C c0 LL ro Q Vj O D' 0) 0) LJ Q M a O a o If z O w ~ o U 0, to d LLJ U Ed O W O O 0' K bn O ENGINEER SEAL C. No 61580 STAT E OF Timothy C. Trewyn, PE P.E. No. 61580 RMPT"M! HY r�r PIERCE ENvT�lW, W. SIM11 K VITM LWIDIY M W SNE CffYR WQM7, mR PIERCE DGINIMM M &L MnS RESERVER I SHEET TITLE I ELECTRICAL DETAILS, RISERS & SCHEDULES I ISSUE DATE: 11-28-2018 I DRAWN: TEC APPROVED: TCT I DRAWING NUMBER I SHEET 6 OF 7 17001-15