Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CONSTRUCTION PLAN PAGE 23-36
Project: m 0 N U 0 V) r u r 0 • ALL CONTROL WIRING FOR VENTILATION SOLUTIONS (VS) EQUIPMENT IS TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. REFER TO VS DRAWINGS FOR CONTROL DEVICE LOCATIONS AND WIRING SPECIFICATIONS. FINAL CONNECTIONS AND PROGRAMMING IS BY VS. • ALL VFD's ARE PROVIDED BY VS. AND INSTALLED BY ELECTRICAL CONTRACTOR (NOTE: RAU VFD's ARE UNIT MOUNTED, ALL OTHERS ARE IN THE ELECTRICAL ROOMS.) • ALL DISCONNECT SWITCHES FOR VS EQUIPMENT ARE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. I HAC-19,21,23 CU-7 3-03�� 15 _ - n 'gam ' '1I s fNF 4-1,3,5 VFDet = NF 3 VF H4-7,9,11 H4-8,10,12 100 VF NF 3 Mnl�l �a� >L.A�3 FOOM 0 2 A KEYED NOTES D RUN CIRCUIT THROUGH VFD LOCATED IN ELECTRICAL ROOM. SEE VENTILATION SOLUTIONS FOR ADOITIONAL DETAILS. GENERAL NOTES THIS DRAWING: • MAINTAIN 42" CLEAR IN FRONT OF ALL ELECTRICAL COMPONENTS, AND AS REQUIRED BY NFPA-70 (N.E.C.)- VERIFY CONDITIONS IN FIELD, COORDINATE WITH ALL TRADES, SUBJECT TO REVIEW BY ARCHITECT/ENGINEER. • DO NOT INSTALL DUCTWORK OR ANY HVAC TRADE ITEM IN SPACE ABOVE ANY ELECTRICAL PANEL AND/OR SENSITIVE ELECTRONIC EQUIPMENT, TYPICAL THROUGHOUT JOB. • CONTRACTOR SHALL PROVIDE SERVICE CLEARANCE AND ACCESS AS SPECIFIED BY THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, TYPICAL ALL EQUIPMENT. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION CU-2 CU-1 HAC-2,urn 1,3,5 4,6 �`-� „ 3 1. 153� lli Al TS ON L01NtR ROOF SECTION CU-6 CU-5 OACU-IA 0ACtJ-1B t.. 3 60 �3 �3 OAC-13,15,17 HAC-56,58,60 I�! I HAC-14,16,18 iQ i LF n � I L � I I _ O I LAV KEYED PLAN ^ ^^ NOT TO SCALE Fm uFHOLSfERY I 9 R H O O1Sl43 I H6-1,3,5 NF H4-50,52,54 5trl r r go_ I H5-1,3,5 003 H5-2,4,6 1-15-25,27,29 \� I NF H5-26,28,30 --=---1--------- ----- - - ----------------- L-- - - -- L1003 N , H4-25,27,29 H4-26,28,30 _ )Q Q .. P 6 H5-7,9,11 1-15-8,10,12 % NF NF Oi Hull Qi Oi f C � Huli Huil Hull � =.�- - --bootlTSkin / Build Build 2 / 5tr1 5tr 2 / VB / PI Hull G za 4 I F^li 1 �19 I , ------------------------------------- ® f 3;n,,ld Retum r ® NF 3 L-1N3 ®- 14Q3VF0 L:7MINnfl VfD H4-32.34.36 H4-37,39,41 H4-38,40.42 H4-43,45,47 H4-44,46,48---------------------- I _ --�_--------------- H4-31,33,35 Q I JNF � 3 0 3 Deck 1\ Flip Deck J f"3 ^NF § DDeck Deck Gri Deck Deck © n . 1 Area 1 Skin Tuild P[iild 2 I HI Nk' Tanks /Pull r. 1403 1-14-49.51,53 1DQ3 NF Q VF41LO-0 NF 3H5- H5-14,16,18 CU-10 30 CU-8 z 15 �fQ / LE CL HAC-26,28,30 HAC- 20,22,24 E _. I 13,15,i n--- ----------------- -- - - - - -- —-- - ----- ------------------- - H4-2,4,6 H4-19.21,23 H4-20,22.24 VFD too 3 _ 1 1 3 1 ® O P � 3 5m. Par-✓ 5m. Parts e �s oot Skin/BI3 tt P[JNF 1 L L � -®- © 5m. Parts Grind�� I H5-19,21,23 - -- -- H5-20,22,24 -------------------------------------- _________________________________________________________________- ------ _.. --------- . PARTIAL ELECTRICAL ROOF PLAN - SOUTII SCALE : 1 /16" = 1'-0- 1IF CORK. = 0 AJ1 FKOF05ED MANUI=ACTUKING DUILDING FOK FUR5UIT 50AT5 5901 5T. LUCIE 5LVD. FORT FIEKCE, FLOKVD Key Plan ,q qR �'•, STATE OF 7W Z 4f LO 55ue5: No.: Date: Description: A. 7/12/19 BID 5ET 6, 7/18/19 PERMIT 5ET 1 C. 9/13'19 CONTRACTOR REVISIONS P. 10/02/19 V.E. REVISION 3 Archcect: DONADIO & Associates, Architects P.A. Vcn, Bc,k h. ILL 324fi11 177 .7W242Y im= 77zsezxnut m v.,hmstRn-unh.avm� AA1M RZ1 ('onoultant: aa CARD nRL IlTES M. 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@C E Aeng ineers. com CA LIC. 31555 Crawko Title: PAKTIAL ELECTRICAL PLAN -50JTH REVIEWED FOR COMPLIANCE eCODE � ST. LUCIE COUNTY Orn: Drawi,l File: N_ Cho: XREF Ale: OL Project .No.: P.ot Ff �: 2018-42 5hee: No.! Cery No.: )ate EiIneo: E -09 i rvwv" it WIP 50A � WELDER II II Jill L1-23 'O L� 8-25,27,291 1 z. Hi II II s 10 H2-20,22,24 11 I. 'i IN -GROUND II II II iI I II II II II WINCH II L11,L9-14116L2-33,35 I n o n 7 / -ni _ I— JLH �0 — -- - t I'(D- - -� O „ „ ®O ------ ------ Euy� � L9-6.81I11I1 IIfI)I �(� - iI �.— 3�4------ � It) a� 99,11 L9-13,15ii iL3-18L1-41 L1- II fi II II I�FAN AFAN R' II II 0 I� �. �� / ABOVE li II as = o �II II II II BAF-7 !III NF II II II II = NF3a3',y I II II H2-19,21.23 _ L1-18 H2-13,15,17 �u- O CRAL- t-30,32 IIII _ A -----kIi�-- 1-3-7- — — — 1/2 N� - — - — - —I BRIDGE 1-3335 " 04 NE O - - 1'IIU - 1 r L1-21 0 II II II II II II II II L1 -2 W z, rr �S5EMF,LY II II II II II II II II II II II II II II II II H2-26,28 30 IIII� O_ III�LL o 3 q��= FUTUR� u 2 L1-19 WINCH II II II II II II , 7,i --_�— " I 11 f� i I I E-12 - I ;.I a= 1I I I ISxI ,i 4=gam galIL 1 II II 60 6031111 t II II O d Lt-15 Lt-13 II II H2- II II L1-4 IIII II II w'�'�IfII o.. [ FAN ABOVE Jill FAN 11 II ffx��--'I��z�j z� � ,55r1 • ABOVE it II II II NS II II BAF-9 II II II it II II IV �� �� II II Jill BAF-6 �� 2<� NF3 Jill II II II II II II II L1-201111 3 'w NF II II H2-14,16.18 II II III z, II II _ 1,R 112-8,10,12 Z` II II N II L9-5,7 ON � a-5 O II II O t I - At - - I L1-6 1 a 1- L1 =11 H1-7.9.11 - i -1 age I L1-7 1-3-8z I i it BAF 5 3 �I FAN NF ABOVE , a� z 1 y 0 II Trim ognbly �,I1-,u 1 II'" LLB, t I L9-25- ti I - - --- -1 li L1-1 ® 50,52,54 L I� H2- ,59 Li-3 H2- -27 49555L9„ ,51,53 ,7II 1 q I EWC Ire mil ---- o , N PARTIAL ELECTRICAL PLAN - N ORTI I SCALE : 1/16" = 1'-0" ALL GENERAL PURPOSE OUTLETS IN THIS AREA MOUNTED AT +42" A.F.F WITH CONDUIT COMING FROM ABOVE. A KEYED NOTES 10 INSTALL ELECTRICAL CONNECTIONS AND MOUNT COLUMN MOUNTED FAN AT 14' A.F.F. CORD DROP OVER WORKSTATION. O3 CONNECT BOOM IN ACCORDANCE WITH APPROVED SHOP DRAWINGS. O CONNECT BRIDGE CRANE 200A BUSWAY IN ACCORDANCE WITH SUPPLIER APPROVED SHOP DRAWINGS. THERE IS A 480V CONNECTION (28 FLA MAX) AND A 120V CONTROL CONNECTION. PROVIDE COMPLETE WIRING CONNECTIONS INCLUDING CONTROLS AND SAFETY INTERLOCKS. O5 PROVIDE COMPLETE CONNECTION FOR HOISTS IN ACCORDANCE WITH APPROVED SHOP DRAWINGS. © PROVIDE CONNECTION TO 50A, 208V, 14, SHORE POWER PROVISION. O7 CONNECT POOL EQUIPMENT IN ACCORDANCE WITH APPROVED SHOP DRAWINGS. PAY PARTICULAR ATTENTION TO NEC. ART 680. ® CONNECT HAND DRYER. 120V. 12A MAXQ 1 GENERAL NOTES THIS DRAWING: • MAINTAIN 420 CLEAR IN FRONT OF ALL ELECTRICAL COMPONENTS, AND AS REQUIRED BY NFPA-70 (N.E.C.), VERIFY CONDITIONS IN FIELD, COORDINATE WITH ALL TRADES, SUBJECT TO REVIEW BY ARCHITECT/ENGINEER. • DO NOT INSTALL DUCTWORK OR ANY HVAC TRADE ITEM IN SPACE ABOVE ANY ELECTRICAL PANEL AND/OR SENSITIVE ELECTRONIC EQUIPMENT, TYPICAL THROUGHOUT JOB. • CONTRACTOR SHALL PROVIDE SERVICE CLEARANCE AND ACCESS AS SPECIFIED BY THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, TYPICAL ALL EQUIPMENT - REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION ®O L3-3 \ `a L3-16 L3-9 Hull stage A I� BAF-4 I� H2-2,4,6 MBLY 3 FAN BAF-3 ABOVE IN 0 H2-1,3,5 NF3 I 1 I I. I I I I I I � I Project: FROF05ED MANUFACTURING 1-3-14 UILDING L3-23 L3-11 `Ik 1 j I L3-21 KEYED PLAN NOT TO SCALE AREA OF WORK THIS DRAWING FOR 'H3'p 'T3'0 PURSUIT 60AT5 5901 5T. LUCIE BLVD. FORT FIERCE, FLORID/A 0 Key Flan 1-3-13 480VATEGF r I I I I I � I 2 , 1 1 � N ' v I Issues: 1 W No.: Date: Description: I A. 7/12/19 BID 5ET L3-15 O B. 7/18/19 PERMIT 5ET 1 2 L3-17 I 480,Q^� I I j I ALL OWNER SUPPLED EQUIPMENT IS TO BE COMPLETELY WIRED AND DEMONSTRATED TO BE OPERATIONAL. CONNECT IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTION'S AND PROVIDE OVERCURRENT PROTECTION IN ACCORDANCE W/EQUIPMENT NAMEPLATE DATA. C. 9/13,/19 CONTRACTOR REVIC)ON5 D. 10/02/19 V.E. REV1510N 3 —' s .'F44 NIUMfit �iYi�tl1�),��d��• A.rchi:eot: D O 1V A D 1 O & Associates, Architects P.A. BIY9 171lyut.h Sh vca, BeucIA329fi11 '1c1.772.791.2929 Iux 772.Sh2.NHX! ,vw.v.dmmJimureh.axn Liecena ]u. AAlXXRrH Consultant: a,a CRRDinAL ,.,. 1:i55C�CIfiTES K1C. 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 G'rawiag Title: FAF,I IAL ELECTKzGAL FLAN -NOKTH Job No-t CODE COMPLIANCE e� ST. LUCIE COUNTY BOC( Drn: Drawing 91c; N- A Cho: XP.EF F11,: DL Project \lo.: r of Fi.,: 2015-4'2 5hee; Nc,: Cert. No.: F late 5i�neo: E —1 O t. dl,, F A. Ill<',Ae r.i•-10 Project: g a M m N U 0 tn 7 r- O m M a_ a 0 0 I 0 1 0 I as U Z V) W F- L) 0 z z W W z UT z W J Z n Of U 9 1Q3 - - _-NIF T H1- H1- 49,51,53 COLLECTOR 55,57,59 KEYED PLAN eN NOT TO SCALE AREA OF WORK THIS DRAWING I _ PARTIAL ELECTRICAL PLAN - NORTH I SCALE : 1 /4' = 1'-0" KEYED N (_)TES Y 10 CORD DROP OVER WORK STATION. GENERAL NOTES THIS DRAWING: O PROVIDE COMPLETE CONNECTION FOR MOTORIZED MAINTAIN 42" CLEAR IN FRONT OF ALL ELECTRICAL COMPONENTS, AND AS OVERHEAD DOORS IN ACCORDANCE WITH APPROVED REQUIRED BY NFPA-70 (N.E.C.), VERIFY CONDITIONS IN FIELD, COORDINATE SHOP DRAWINGS INCLUDING CONTROLS AND SAFETY WITH ALL TRADES, SUBJECT TO REVIEW BY ARCHITECT/ENGINEER. INTERLOCKS. • DO NOT INSTALL DUCTWORK OR ANY HVAC TRADE ITEM IN SPACE ABOVE ANY ELECTRICAL PANEL AND/OR SENSITIVE ELECTRONIC EQUIPMENT, TYPICAL THROUGHOUT JOB. • CONTRACTOR SHALL PROVIDE SERVICE CLEARANCE AND ACCESS AS SPECIFIED BY THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, TYPICAL ALL EQUIPMENT. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION E E 0 0 Y FL co L2-13 L2—�17 ALL GENERAL PURPOSE OUTLETS IN THIS AREA MOUNTED AT +42' A.F.F NTH CONDUIT COMING N FROM ABOVE. w u W W z z � F MILL SHOP 0) •L U 0 cti 0 LL L2—.Im .E A 1s =3 N rr) Ld W I W rLdw(nJ._"-___ J U Q 3 a ¢ A 1 ALL OWNER SUPPLIED EQUIPMENT IS TO BE COMPLETELY WRI_-D AND DEMONSTRATED TO BE OPERATIONAL. CONNECT IN ACCORDANCE WITH MANUFACTURI R'S INSTALLATION INSTRUCTION'S AND PROVIDE OVERCURRENT PROTECTION IN ACCORDANCE W/EQUIPMENT NAMEPLATE DATA. FROF05ED MANUFACTUKING 13UILDING FOR FUR5UIT BOATS 5901 5T. LUCIE BLVD. FORT FIERCE, FLORIDA Key Plan ���I11111111 // N .��°;§� /.tom✓ N7lT�* .OF 155ue5: No.: Date: Description: A. 7/12/19 DID 5ET D. 7118119 PERMIT BET C. 9115.119 CONTRACTOR REV151DN5 D. 10/02/19 V.E. KEV15ION 3 lk _i �i Archrect: DONADIO & Associates, Architects P.A. MN 17,h Slrt;'x Vcnr BuuGl. I•L 32Wd1 A A 772.794 2929 +un.772Sfi2.IfiAA1 vw.Jmmifio-un:h.e,rtn Lic::nry .\,,. AAQXM ,h Consultant: ma CRRDInRL r-r4!'Essr_cR!21f" RSSr?rEPTF_S 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 Crawing Title: PARTIAL ELECTRICAL PLAN -NORTH Job No-tl REVIEWED FOR CODE COMPLIANCE e� ST. LUCIE COUNTY BOCC Prn: Drawl�File: N_ .-ho: XREF Flle: DL Project No.: P.ot Fis: 2018-42 5heez No: usrt. No.: late 5-gneo: E —1 2 Froject: KEYED PLAN NOT TO SCALE AREA OF WORK THIS DRAWING L1 Z Z H H I I I L2-7 o�0 cc O LL _Occ i = cC/3 C� U 1 I > 0 1 I I V- 4I Ilz 1 � L I U I f I I I I I 1 I 1 I II 1 I i I MILL SHOP s eO 119upeo II! 02 I I I IE M 1 L ICU I I � m I o i I L2-36 J (D In I I I r U N I r I o I m I- w 0 U } O 1 o ! IICU _2-131-2-15 I (1� L2-19 Q m � � WIR I I z w w w w N I fn W W Z Z J J mI m L2-40 O H2-37,39,41 L2- 38 H2-43,45,47 0 Ls-21,2s a 1 L2-25, 27 L2-22 L2-29,31 KEYED NOTES OX CORD DROP OVER WORKSTATION. VERIFY EXACT LOCATIONS GENERAL NOTES THIS DRAWING: IN FIELD WITH OWNER/ARCHITECT. Q MAINTAIN 42" CLEAR IN FRONT OF ALL ELECTRICAL COMPONENTS, AND AS O CONNECT BOOTH LTS AND RECEPS_ REQUIRED BY NFPA-70 (N.E.C.), VERIFY CONDITIONS IN FIELD, COORDINATE WITH ALL TRADES, SUBJECT TO REVIEW BY ARCHITECT/ENGINEER. O3 PROVIDE COMPLETE CONNECTION FOR MOTORIZED OVERHEAD DOORS IN ACCORDANCE WITH APPROVED SHOP DRAWINGS DO NOT INSTALL DUCTWORK OR ANY HVAC TRADE ITEM IN SPACE ABOVE ANY INCLUDING CONTROLS AND SAFETY INTERLOCKS. ELECTRICAL PANEL AND/OR SENSITIVE ELECTRONIC EQUIPMENT, TYPICAL THROUGHOUT JOB. O4 CONNECT 1/2 TON FIXED BEAM HOIST IN ACCORDANCE WITH CONTRACTOR SHALL PROVIDE SERVICE CLEARANCE AND ACCESS AS SPECIFIED SHOP DRAWINGS. BY THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, TYPICAL ALL EQUIPMENT. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION L2-6 (� .0 O C10 O O. 0 LL. re 0 C) PARTIAL ELECTRICAL PLAN - N ORTI I SCALE : 1/1- = 1'-0" .E IL .6 KI1 ME, L2-21 L2-11 L.2-42 0 y H8-18,20,22 0 ALL OWNER SUPPLIED EQUIPMENT IS TO BE COMPLETELY WIRED AND DEMONSTRATED TO BE OPERATIONAL. CONNECT IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTION'S AND PROVIDE OVERCURRENT PROTECTION IN ACCORDANCE W/EQUIPMENT NAMEPLATE DATA. FROF05ED MANUFACTURING DUILDING FOR FURSUIT DOATS 5901 5T. LUCIE BLVD. FORT FIERCE, FLORIDA Key Flan sG /i i i •A STATE OF51 �41 izNAi I\?\���� Iseuee: No.: Date. De5criptior: A. 7/12/19 BID 5ET 13, 7/15/19 PERMIT 5ET 1 C. 9113/19 CONTRACTOR REV151ON5 D. 10/02/19 V.E. REV1510N 3 A.rchi:ect: DONADIO & Associates, Architects P.A. " I7ih SWW Vca, 3. i. 11721M1 '10 772 7941 N2 I ux.772.562,StAX1 www �Imiadin-amh.mm� Lw,v,, M, AAQX1227S Conoultant: (Boa CARD AL 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 DraMig Title: FAKTIAL ELECTICAL FLAN -NOP,TH REVIEWED FOR yob No t CODE COMPLIANCE ST. LUCIE COUNTY e� BOCC Drn: Drawiig File: t\_ ;;ho: XREF Flle: DL Project %.: F:ot Fk: 201B-42 5hee', No: Cert, No.: late 5pned: E -1 `�r'�) ig [ C77C:8,;%craA'e5A-:�t at^e.4•ciAvs. F.+, 1111g,t. rvr-+sd CONTROLS LEGEND SYMBOL MODEL/DESCRIPTION GDS-1 TLB-W OGDS1 GDS GREENGATE DIGITAL SWITCH DTI-R OAC-OT-1000-R �(®» 360 DEGREE 1000FT2 DT v CEILING SENSOR DT2-R OAC-DT-2000-R 360 DEGREE 2000Fr DT v CEILING SENSOR SP20-RD4 ®L 120/277VAC SINGLE RELAY SWITCHPACK FOR LIGHTING LOADS I------------------------------------------------ 0 fN Y U a o_ J 3 O Of LJ uj cV O I W 0 F- LL W d' SYMBOL MODEL/DESCRIPTION GMDS-W OS MS MOMENTARY SWITCH FOR OVERRIDING SENSOR ONW-D-1001-MV-W © 120/277VAC SINGLE RELAY DT WALL SWITCH SENSOR CEPC-2 EM UL924 EMERGENCY RELAY 0 REFER TO E-02 FOR EXTERIOR WALL PACKS / I PARTIAL LIGHTING PLAN - SOUTII SCALE : 1 /8" = 1'-0" KEYED NOTES Y O SEE MOUNTING DETAIL ON E-20 FOR TYPE 0 &® FIXTURES. PROVIDE DEDUCTIVE ALTERNATE FOR OWNER TO SUPPLY AND INSTALL TYPE QA & qD FIXTURES (CONTRACTOR TO INSTALL RECEPTACLES) GENERAL NOTES THIS DRAWING: CROSS HATCHED FIXTURES ARE TO CONTAIN EMERGENCY BATTERY PACK FOR EMERGENCY LIGHTING- EMERGENCY LIGHTS NOTED "NL" ARE ALSO NIGHT LIGHTS ON 24 HRS. Q REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION REFER TO E-20 & E-21 FOR CONTROLS, SCHEDULES. P1 L-----: -- J 11 r ai KEYED PLAN NOT TO SCALE AREA OF WORK THIS DRAWING m n wlw 0 `� 3Y1, LJcasl 1 do im E � N LCP1-6 sL �j o ��en I di LCF'1-.5 DTI i�na t] T �I + I1 r 1 '1 i ) i i I CO h ww w w Z Z J � J h 0 012-R .'AwDT2-R G. .SC DT22 wlr9 Lm K-< no � U�iVJI PWi]VIAN --?, - 2)- ,, DT2-R ,� DT2-11 Project; FKOF05EP MANUFACTURING DUILDING FOK FUR5UIT 50AT5 3901 5T. LUCIE BLVD. FOKT FIEKCE, FLORIDA Key Plan H No 477 STATE GF �u S�0NAf; 5\\`\\ 155ue5: No.: Date: Description: A- 7/12/19 DID 5ET 6. 7/15/19 PERMIT 5ET Al C. 9/13./19 CONTRACTOR REV1510N5 D. 10/02/19 V.E. KEV15ION 3 k - Architect: DONADIO & Associates, Architects P.A. (SIN M:: SWaL V"Bc. h, 1•La ) ' J.772.794.2929 I-us.772.562XAX) wmw.,kmudw-awham, LZ,on , No. AAUX�,N ('onbultant: CRRDinFIL 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 Drawing Title: PARTIAL LIGHTING FLAN -50UTH Job No-th REVIhWt:u FOR CODE COMPLIANCE e� ST. LUCIE COI. N'T-" BOCC Drn: Drawiig File: k_ r-ho: XREF FIL: X Project Na: F,ot F'ie: 2015-4'2 Sheet No: Geri. No.: Date soneo: E -1 `�"G W W z z a ¢ o flz H Kis t < 0 Im M G A L lr.N 0-ST-17 LCP1-6 N / CIErn a' „ DT2-R p'Ir9 I 1 � WI W W ' W z z <) I r 1q CONTROLS LEGEND SYMBOL MODEL/DESCRIPTION GDS-1 TLB-W OS GDS1 GDS GREENGATE DIGITAL SWITCH OT1-R OAC-DT-1000-R go$ 360 DEGREE 1000FT2 DT CEILING SENSOR ❑T2-R OAC-DT-2000-R KI®)) 360 DEGREE 2000Fr DT v CEILING SENSOR SP20-RD4 -L 120/277VAC SINGLE RELAY SWITCHPACK FOR LIGHTING LOADS Z:D r 7LGPi —16 `__------ l_•�---------------- -- w DT2-R ( n /1 /i=1 2 Lam_ f t 'N SYMBOL MODEL/DESCRIPTION GMDS-W OMg MOMENTARY SWITCH FOR OVERRIDING SENSOR ON W-D-1001-M V- W 120/277VAC SINGLE RELAY DT WALL SWITCH SENSOR EM CEPC-2 UL924 EMERGENCY RELAY KEYED NOTES Y O SEE MOUNTING DETAIL ON E-20 FOR TYPE Q&®FIXTURES. PROVIDE DEDUCTIVE ALTERNATE FOR OWNER TO SUPPLY AND INSTALL TYPE ® & ® FIXTURES (CONTRACTOR TO INSTALL RECEPTACLES) GENERAL NOTES THIS DRAWING: CROSS HATCHED FIXTURES ARE TOCONTAIN EMERGENCY LIGHTING- BATTERY PACK FOR EMERGENCY LIGHTING- EMERGENCY LIGHTS NOTED "NL" ARE ALSO NIGHT LIGHTS ON 24 HR& Q REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION REFER TO E-20 & E-21 FOR CONTROLS, SCHEDULES. 0 0 —REFER TO E-02 FOR EXTERIOR WALL PACKS - us lJtiVs7 yK L _ -_ — — — __ _ -j © - E2'�—�I CDc, nT2-ci I I`—I� 1► I - '' LCP2-1 II HS-1 © C-A - II I! 1 LCP1 -3 1 „ DT2-R I �/ Q i C1 LCPi'-1 DT2-R ' Eb1 i D D �r I I-- —-------- —� o`f e _ c CPI-9 07—"Z'LCI'1--8 � `I �� DE-R EM� T2 I ®�I 4I 0 -/ e C41 Of S_ 11 s 42D C1 N • r- I - I DTl ® D 1 r14 X F� V F OS GDS1 - _ - GDS1 0 - ------------ E-18 i PARTIAL LIGHTING PLAN - SOUTI I N SCALE : 1 /8" = 1'-O" Z�I KEYED PLAN NOT TO SCALE AREA O THIS C H8-31 Project: FROF05ED MANUFACTUKING P UILDING FOK FUK5UIT 50AT5 5901 5T. LUCIE E5LVD. FORT FIERCE, FLORIDA Key Flan lN d 1 84T. 10, STATE OF ; �l I II 155ue5: No.: Date: De5criptior: A. 7/12/19 BID SET B. 7/18/19 PERMIT 5ET 1 C. 9/13!19 CONTRACTOR REV1510N5 D. 10/02/19 V.E. REVISION 3 Archr,00t: DONADIO & Associates, Architects P.A. (ANI IAA, tirw Vcnr licuc h, I•L 324fA) I J.772.791.21tN Fux.772S62.Wb ... A mut io-u d.r Lk ," ]u. AAIXX)M;H Consultant: aa CARoinRL -ERIf1G R5 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCI E FL 34986 T.561.746.6343 F.561.746.3602 info@CEAeng ineers.com CA LIC. 31555 Drawing Title: PARTIAL LIGHTING PLAN -50UTH Job No:'-ti REVIEWED FOR — CODE COMPLIANCE )�ST. LUCIECOUNTY BOCC Drn: Drawing Fils: N_ Cho: XREF He: DL Froject No.: F ot F'I:e: 2018-4.2 Dhee; No.: Cert. No.: 7 Date 51'�YIeO: E -1 .: y-iJ-t Cei.:=.,:.iaA'o:4P;.'v�ci.L^9.9....i4a;',. f.}..iIIz.H.iY f'�:•viA Project: Ah 0 N L) U 0 Xn ei r e a' Y U Q a J J Q O Ld W F— x W w Q N O 1 W O F— d' W Ld w I SYMBOL CONTROLS LEGEND MODEL/DESCRIPTION SYMBOL MODEL/DESCRIPTION GDS-1 TLB—W GMDS—W OGDSI GDS GREENGATE OS ms MOMENTARY SWITCH FOR DIGITAL SWITCH OVERRIDING SENSOR DTI-R gob DT2-R KPH v OAC—OT-1000—R 360 DEGREE 1000Fr DT CEILING SENSOR OAC—DT-2000—R 360 DEGREE 2000FT' DT CEILING SENSOR SP20—RD4 120/277VAC SINGLE ®L RELAY SWITCHPACK FOR LIGHTING LOADS ON W—D-1001—M V— W 120/277VAC SINGLE RELAY DT WALL SWITCH SENSOR CEPC-2 EM UL924 EMERGENCY RELAY KEYED NOTES Y 0 GENERAL NOTES THIS DRAWING: CROSS HATCHED FIXTURES ARE TO CONTAIN EMERGENCY BATTERY PACK FOR EMERGENCY LIGHTING- EMERGENCY LIGHTS NOTED "NL" ARE ALSO NIGHT LIGHTS ON 24 HRS. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION REFER TO E-20 & E-21 FOR CONTROLS, SCHEDULES. _ _ _._.__-1-------------- PARTIAL LIGI ITING PLAN - SOLJTI I SCALE : 1/16" = 1'-0" A KEYED PLAN I^ NOT TO SCALE I a AREA OF WORK !, _ THIS DRAWING i ,��.�.. >-. ..-,� s"m„-can®.-avuw,n-•ea�.�=v,.�a mia'.sa�y'u.%�,.�>A'�. I I I. 1-- I I ----------- - -- ------ - L�, MAN UI=ACTUKING BUILDING FOK FUR5UIT DOAT5 5901 5T. LUCIE BLVD. FORT FIERCE, FLOKIDA Key Plan �, EIOI/�9, //////Sr6AlIIII11 1 \\\\ loouee: No.: Date: Description: A. 7/12/19 BID SET B. 7/18/19 PEFMIT 5ET 1 C. 9/13.19 CONTRACTOR REVI6ION5 D. 10/02/19 V.E. REVISION 3 ArchGCCt: DONADIO & Associates, Architects P.A. b(y4 17Lh tiiraL Vcn> Bc. I132W) 5'07.772.7V1.29N Vnx 772_W WAX) vww.d,miudio-unitam� Lii vna:; \,i AMAXll2 (-On5nitant: cARDmAL 110 RS50c1R T'1. 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC, 31555 Drawiea Title: FAF,TIAL LIGHTING PLAN -50UTH REVIEWED FOR Job No:•tl CODE COMPLIANCE e ST. LUCIE COUNTY BOCC Drn: Drawing File: Cho: XKEF FIL=: DL Project No.: F of Fi:e: 2015-42 Ghee; No.: C=rt. No.: Date Sijneo: E -1 "' I &) IG'S, ;ic+eW'o .. Aa=a;t:6s5, A ^-i SPV'15. P-A, ' ]1 c.,,4? &h^-1H Project: BOOTH SEICTION SCALE : 1/2" = 1'—O" L' FLOOR PLAN - GEL BOOTH SCALE : 1/4" = 1'-0" �i4 �iTl�l 4 �I IJimi iwi7low li 3 1100. FLOOR PLAN - GEL BOOTH (TYP) SCALE : 1/4" = 1'—O" KEYED PLAN NOT TO SCALE AREA OF WORK -- THIS DRAWING ug IT KEYED NOTES Y 1O COORDINATE BOOTH LIGHTING FIXTURES AND CONNECTION DETAILS IN FIELD. PAY ATTENTION TO CLASSIFIED LOCATION! LISTINGS. CROSS HATCHED FIXTURES ARE TO CONTAIN EMERGENCY BATTERY PACK FOR EMERGENCY LIGHTING. EMERGENCY LIGHTS NOTED "NL" ARE ALSO NIGHT LIGHTS ON 24 HRS. REFER TO ARCHITECTURAL & MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION REFER TO E-20 & E-21 FOR CONTROLS, SCHEDULES, FROF05ED MANUFACTURING DUILPING FOK FURSUIT DOATS 5901 5T. LUCIE BLVD. FORT FIERCE, FLORIDA Key Flan LA � 0p STATE OF Ge � 1551185: No.: Date: Description: A. 7/12/19 BID 5ET 5. 7/1B/19 PERMIT 5ET 1 C. 9113/19 CONTRAGTOR REV151ON5 D. 10/02/19 V.E. REV15ION a aF4 CA 4 y,, I P I 1 Arefil:eot: DONADIO & Associates, Architects P.A. M9 17th S=L vcro 9cuch, ICIM) 'I A 772.79 4.292.4 I�uz.772.502.IkAN/ www.dmwA"-urolurmt Liccnec \'u. .4AIMNV21i Con5111tant: --E 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 Drawing Titlo: LIGHTING PLAN -BOOTH 5 REVIEWED FOR Job NO—L, CODE COMPLIANCE ST. LUCIE COUNTY )29 BOCC Drn: Drawilg Filo: N_ Cho: XREF Rio: DL Project No.: F.ot Fl:e 2018-42 Shoe; No.: Cert. No.: Date Signeo: E -18 A w Y U a J J 3 w x X uj N w O I — Of w tL w T II II -------------- I II II � I! II II !I I II II iF II ! II ---------------------- it II oll�' ! II II II II II II II II II II II II kiiii UIIIC II II II II II II II II II II II II ii C II II II II II II � II II MEN �':JI F LCP2-14 N _ I � CC a IL o GDS S -yasn. ° O ° ° REFER C()NTROLS LEGEND SYMBOL MODEL/DESCRIPTION SYMBOL MODEL/DESCRIPTION 0GDS1 GDS-1 TLB—W GDS GREENGATE OS rols GMDS—W MOMENTARY SWITCH FOR DIGITAL SWITCH OVERRIDING SENSOR 1)T1-R OAC—OT-1000—R ONW—D-1001—MV—W 7VAC SINGLE / 360 DEGREE 1000Fr DT RELLAYAY D DT WALL SWITCH v CEILING SENSOR SENSOR DT2-R OAC—DT-2000—R CEPC_ {(®�} 360 DEGREE 2000Fr DT EM UL924 EMERGENCY RELAY v CEILING SENSOR SP2D—RD4 ®L 120/277VAC SINGLE RELAY SWITCHPACK FOR LIGHTING LOADS KEYED N (-)TES Y 0 GENERAL NOTES THIS DRAWING: CROSS HATCHED FIXTURES ARE TO CONTAIN EMERGENCY BATTERY PACK FOR EMERGENCY LIGHTING. EMERGENCY LIGHTS NOTED "NL" ARE ALSO NIGHT LIGHTS ON 24 HRS- Q REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION REFER TO E-20 & E-21 FOR CONTROLS, SCHEDULES. I WW1 II II II 11 !III il��I !fl _ � II II II C II III it ® LCH8-5 C LH8-_ 13 C e. C t � 1, lil 11 I! II II �- � II II II ii �Illi Illi � II II !II II II I! I�, (I11 II �II'II II`�I C Dec IIII I�II— C — — ry -- -- L — — LC2— C II 4CP2-4 II II H8-15 8-7 IN II !! II II II II II II Ii C u II © II II C LCP2-5 C C LCP2-9 III II II H8-9 1-18-17 Cs II II C j C II II !! II <a >So C M H8-10 LCP2-10 H8-19 II ,� VH[I4LLLI Trim A y I LCP2-A ti HB_6 C L — H8-24 IN C LCP2 03 /� ! r______17D S H8-45 , ----, cosA�l ------------------- ga__ E-17 1; h ! -- — PARTIAL LIGHTING G PLAN - N (_)RTI I SCALE : 1 /16" = 1'-0- KEYED PLAN �V NOT TO SCALE AREA OF WORK THIS DRAWING r---1 \S �GIn1 y L - LlNL - ?J ,I A55EM�LY of ! \II _ I 1 I I I I C C C C I C I I L 1. 1 _ `T C H8-8 C L C C L C I i I I I i I 7II I I I I I I II I I; I I I II I I I I I _ IUa ! i LAMINATION i i 1 � I I I I I I I N n II II II n II II II II II II II II II II Project: FKO 05ED MANUFACTURING DUILDING FOR PURSUIT MATS 3901 5T. LUCIE DLVD. FOKT FIEKCE, FLOizIDA Key Plan K14 _ — 10 �+ STATE OF ; ;w= 155ue5: No.: Date: De5criptior: A. 7/12A9 130 5ET 5. I/18/19 PERMIT 5ET 1 C. 9/13/19 CONTRACTOR REV1510N5 D. 10/D2/I9 V.E. REV1510N gas Ar'chitecb. DONADIO & Associates, Architects P.A. 609 17ih Shwa Van. Banc. h, Ia.:i21NA1 1 1772.7!u 2929 1 772.SE2.WAX1 v v d+mudio an;la,en AAINNM8 Cor sultan �: Via CFl_oRinu inFIL 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 Drawing Title: F'AF,TIAL LIGHTING FLAN -NOKTH REVIEWED FOR Job No-tl MPLI,-AC17— ST. LUCIE CCUN-ry e� B®CC 7rn: Drawing File: N- Chn: WE File: 7_ 'reject No.: Plot File: 2015-42 sheet t 0.: Gert,No: Date 5bned: `— —1 9 STANDARD LIGHTING POLE DETAIL (1) LIGHTING POLE. THE MANUFACTURER IS TO PROVIDE CERTIFICATION BY FLORIDA PE, SHOWING WIND LOAD RATING OF 170 MPH WITH SPECIFIED FIXTURES INSTALLED. THE FINAL POLE SET IS TO BE DETERMINED BY THE PROFESSIONAL ENGINEER. (2) INTERNAL WIRING. INTERNAL WIRING TO BE IN UL LISTED CONDUITS, INSIDE POLE. SEE NOTE 3. (3) LIGHT FIXTURE CONNECTIONS. REFER TO LIGHT MANUFACTURER FOR REQUIREMENTS, INCLUDING TEMPERATURE REQUIREMENTS (COMMONLY 150C). CONDUCTORS TO BE UL LISTED "FIXTURE' CONDUCTORS. UL "RECOGNIZED" APPLIANCE WIRES NOT PERMITTED.) OBTAIN BUILDING DEPARTMENT APPROVAL FOR CONDUCTORS, CONNECTORS, AND ACCESSIBILITY. (4) CONDUITS. CONDUITS BELOW HAND HOLE IN POLE TO BE UL LISTED WITH -BRANCH CIRCUIT' THWN CONDUCTORS. (5) HAND HOLE. HAND HOLE WITH UL LISTED BOX CAST IN POLE WITH WATERPROOF SPLICES. (6) GROUND WIRE IN POLE. CONNECT BOTTOM TO #4 BARE GROUND CONDUCTOR. CONNECT TOP TO GROUND LUG IN FIXTURES. (7) TRAFFIC RATED PULL BOX. HIGH STRENGTH COMPOSITE CONSTRUCTION RATED FOR DESIGN LOAD OF 5,000 LEIS OVER A 10" SQUARE. COVER LETTERING = "LIGHTING DO NOT PLACE IN PAVED AREA, KEEP IN GRASSED AREAS. QUAZITE COMPOSOLITE PX STYLE. 1-800-346-3067 (8) MUCK. IF SOFT SOILS ARE FOUND ON THE PROPERTY, THIS POLE DESIGN WALL BE MODIFIED TO ACCOMMODATE. NOTIFY ENGINEER IMMEDIATELY. (9) SITE CONDITIONS. IF SITE CONDITIONS ARE DISCOVERED WHICH REQUIRE ANY POLE (S) TO BE MOVED OVER 4 FEET, NOTIFY THE ENGINEER IMMEDIATELY. LIGHT POLE DETAIL NOT TO SCALE PURSUIT BOAT WORKS+A1:123 LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MFR CATALOG NUMBER VOLTS LAMPS MOUNTING REMARKS C1 LED HIGH BAY FIXTURE METALUX OHB-60SE-W-UNV-L840-CD-U UNV Q 1 375.9W SURFACE CORD AND PLUG -LENGTH TB CE1 LED HIGH BAY FIXTURE WITH INTEGRAL BATTERY PACK 1 METALUX OHB-60SE-W-UNV-EL20W-CD-U UNV 1 375.9W SURFACE CORD AND PLUG LENGTH TBD B LED WALL LINEAR METALUX 4SWLED-28SL-LW-UNV-L840-CD1-U UNV 24.8W SURFACE C LED HIGH BAY FIXTURE METALUX HBLED-LD5-60SE-W-CLI-480V-L840-ED4-U 480V 386VV SURFACE 1 CE LED HIGH BAY FIXTURE WITH INTEGRAL BATTERY PACK 3 METALUX IHBLED-LD5-60SE-W-CLI-480V-L840-EL14W-ED4-U 480V 386W SURFACE D LED 2X4 FLAT PANEL METALUX 24FP4740C / DF-24W-U UNV 40.3W SURFACE DE LED 2X4 FLAT PANEL WITH INTEGRAL BATTERY PACK 1 METALUX 24FP4740C- OF 24-U 1Q UNV 40.3W SURFACE E LED 2X2 TROFFER METALUX 22CZ2-24-UNV-L840-CD1-U UNV 21.9W RECESSED EE LED2X2 TROFFER WITH INTEGRAL BATTERY PACK 1 METALUX 22CZ2-24-UNV-L840-CD1-U 1Q UNV 21.9W RECESSED E2 LED 2k2TROFFER METALUX 22CZ2-44-UNV-L840-CD1-U UNV 42.7W RECESSED E2E LED 2X2 TROFFER WITH INTEGRAL BATTERY PACK AS METALUX I 22CZ2-44-UNV-L840-CD1-U 1� UNV 42.7W RECESSED F LED 5-6" IC DOWNLIGHT HALO RL560WH9840 UNV 13.5W RECESSED G DOCK LIGHT NSD DL60-18-HD-FAN 120 18W LED PER PLANS H CANOPY LIGHT MCGRAW EDISON TT-C3-LED-E1-RW-XX UNV 45W LED SURFACE K VAPOR TIGHT4'LED MCGRAW EDISON 4VT3-LD5-46-UNV-L840-CD1-U UNV I 31WLED SURFACE KE 1 VAPOR TIGHT 4' LED WITH INTEGRAL BATTERY BACKUP MCGRAW EDISON 4VT3-LD5 46 UNV-ELT OW-CDT-U UNV I /\ 31 W LED SURFACE X EXIT LIGHT ISOLITE RL-EM-G-WOO UNV 4W LED PER PLAN ARROWS PER PLAN FIXTURE SCHEDULE NOTES FOR QUESTIONS PERTAINING TO THIS FIXTURE SCHEDULE PLEASE CONTACT TONY PLONNER @ LIGHTING DYNAMICS (561) 718.8917 I PURSUIT BOAT FACILITY - PHASE 1A & 1 B SITE LIGHTING FIXTURE SCHEDULE TYPE DECRIPTION MFR CATALOG NUMBER VOLTS LAMPS WATTS Dimming MOUNTING REMARKS SA POLE MOUNTED LED FIXTURE MCGRAW-EDISON GLEON-AF-06-LED-E1-5WQ-FINISH / MA1036-M 120-277V LED 333VV N/A 25FT POLE NOTES 1, 2 SB POLE MOUNTED LED FIXTURE MCGRAW-EDISON GLEON-AF-06-LED-El-T3-FINISH / MA1036-XX 120-277V LED 333W N/A 25FT POLE NOTES 1, 2 Sc POLE MOUNTED LED FIXTURE MCGRAW-EDISON GLEON-AF-06-LED-El-T4W-FINISH I MA1036-XX 120-277V LED 333VV N/A 25FT POLE NOTES 1,2 SD POLE MOUNTED LED FIXTURE MCGRAW-EDISON GLEON-AF-06-LED-Ei-T47--FINISH / MA1036-XX 120-277V LED 333W N/A 25FT POLE NOTES 1, 2 SW WALL MOUNTED LED FIXTURE MCGRAW-EDISON GIVC-AF-02-LED-EI-T4FT-FINISH 120-277V LED 113W N/A 25FT AFG WALL MOUNTED NOTES 1, 3 FIXTURE SCHEDULE NOTES NOTE 1: PLEASE ADVICE FINISH. NOTE 2: FIXTURE MOUNTED ON 25FT AFG ROUND TAPERED EMBEDDED (DIRECT BURIAL) ALUMINUM POLE VALMONT#: 240840606TEP2-FINISH. NOTE 3: FD(1URE WALL MOUNTED AT 25FTAFG. PLEASE VERIFY AND CONFIRM MOUNTING HEIGHTAND FIXTURE LOCATION. FORQUESTIONS PERTAINING TO THIS FIXTURE SCHEDULE PLEASE CONTACTTONY PLONNER @ LIGHTING DYNAMICS-(561) 718-8917; TPLONNER@LIGHTINGDYNAMICS.COM Project: iROF05ED MANUI=ACTUKING DUILDING FOK PURSUIT 130AT5 5901 5T. LUCIE BLVD. FORT FIERCE, FLORIDA Key Plan ;Lu._ �, gTP1E GF w� %�0,,;•. FLORA°P'���� 155Ue5: No.: Date: De5criptior: A. 7112/19 511) 5ET 5. 7/1c9/19 f EPMIT 5ET 1 C. 9113/19 CONTRACTOR FEV1510N5 D. 10/02/19 V.E. REV1510N 3 A.rchitsct: DONADIO & Associates, Architects P.A. M9 17 ih SW= V,n, l3�.h. 11, 3NW Tc1.77174+.242V I!IN72562. WAO ww,v J,mu,fio-u¢haxn Liconnu ]u. .4AlNN)ZZiR Gohyultart: aa 149 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 Drawing TF e: LIGHING CONI-ROL5, 5CHEf?ULE5 & MOUNTING DETAIL5 Job No-v _ -- • v. CODE COMPLIANCE e� ST. LUCIE COUNTY BOCC orn: Gnawing File: NIL Chd: XWE° Pill: DL Pro'ecz No.: Plot Pile: 2018-42 Sheet Na: Cer;. No.: Date 5'q ned; E — 2 v 5:;:F. LWAI:.'A „1.4,o.,i::+teat6. P.A. Al Eo An M s N U An Ad r ui 0 m 5 N M o_ 0 I 0 I a] O I o) zz N w r Q U N a 0 z Ld it w z z 5 z w z 0 a Additional 5 OCC Sensors circuits (See plans for locations) OAC-DT-1000-R GDS-1 TLB—W GDS-1 TLB—W GDS-1 TLB—W GDS-1 TLB—W GDS-1 TLB—W �_ k — I GDS-I-KIT 0 GD�Button White — Control Station RRU-1-277 UL924 accessory Sense 277V Normal Power H8-43 To Lighting Loads o 120/277V Transfo er Power Dedicated Circuit (L1-14) LCP1 CKT48-120/277-SSO-SL8-STO-SHVBO-SHVDO Relay Panel with 48 latching relays (120/277V) 1—Button M e GDS —Control tation GDS-I-KIT Bu ton GD� Whi e — ontrol tation 1—Button White GDS — Control Station RRU-1-277 UL924 accessory Sense 277V Normal Power H7-43 Additional 5 OCC Sensors circuits (See plans for locations) To Lighting Loads Trasformer ower Cinrcuit (L1-1 ) LCP2 CKT24-120/277-SSO-SLO-STI2-SHV61-'SHVDO Relay Panel with 12 two -pole relays (48OV) 1 Button white GDS —Control Station 1—Button White GDS — Control Station GDS-I-KIT To Lighting Loads Bu ton Whi e GD — ontrol tation 1—Button White GDS — Control Station GDS—ITLB—W GD;Button White —Control Station Trangfo er P wer Circuit (L6-273 LCP3 CKT24-120/277-SSO-SLO-STI2-SHVBI-SHVDO Relay Panel with 12 two -pole relays (ASV) CONTROL PANEL SCHEDULE'LCP1' (Pursuit Boat Works) -120/277V Panelr5ay Area Control Type Load Description Dimming LCP1CORR.13 TIMECLOCK/OVERRIDE SWITCH LED NONE LCP1PANTRY16 TIMECLOCK/OVERRIDE SWITCH/OCCSENSOR LED NONE LCP1BREAK ROOM 17TIMECLOCK/OVERRIDE rE SWITCH/OCCSENSOR LED NONE LCP1OPENCFFICE09TIMECLOCK/OVER RIDE SWITCH/OCCSENSOR LED NONE LCP1 OFF. 10 TIMECLOCK/OVERRIDE SWITCH/OCCSENSOR LED NONE LCP1 6 OFF. 11 TIMECLOCK/OVERRIDE SWITCH/OCCSENSOR LED NONE LCP1 7 OFF. 12 E&EE O TIMECLOCK/OVERRIDE SWITCH/OCCSENSOR LED NONE LCP1 8 STO13A TIMECLOCK/OVERRIDE SWITCH/OCC SEN SOR LED NONE LCP1 9 STO13B D TIMECLOCK/OVERRIDE SWITCH/OCCSENSOR LED NONE LCP1 10 OFF. 10 RECEPTACLED TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 11 OFF. 11 RECEPTACLED TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 12 OFF. 12 RECEPTACLED TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 13 MEN'S 14 B,D,F TIMECLOCK/OVERRIDE SWITCH/OCCSENSOR LED NONE LCP1 14 WOMEN'S15 B,D,F TIMECLOCK/OVER RIDE SWITCH/OCCSENSOR LED NONE LCP1 15 ELEC.18 A&AE TIMECLOCK/OVERRIDE SWITCH/OCCSENSOR LED NONE LCP1 16 ELEC.18 A&AE TIMECLOCK/OVERRIDE SWITCH/OCCSENSOR LED NONE LCP1 17 ELEC.18 A&AE TIMECLOCK/OVERRIDE SWITCH/OCCSENSOR LED NONE LCP1 18 UPHOLSTERY A&AE A&AE TIMECLOCK/OVERRIDE SWITCH/OCCSENSOR LED NONE LCP1 19 UPHOLSTERY TIMECLOCK/OVERRIDE SWITCH/OCCSENSOR LED __ __NONE LCP1 20 OPEN OFFICE PARTITION TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 21 OPEN OFFICE PARTITION TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 22 OPEN OFFICE PARTITION TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 23 OPEN OFFICE PARTITION TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 24 OPEN OFFICE PARTITION TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 25 OPEN OFFICE PARTITION TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 26 OPEN OFFICE PARTITION TI MECLOCK/OV ERR] DE SWITCH RECEPTACLE NONE LCP1 27 JOPEN OFFICE PARTITION TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 28 OPEN OFFICE PARTITION TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 29 OPEN OFFICE PARTITION TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 30 BREAKROOM RECEPTACLED TIMECLOCK/OVERRIDESWITCH RECEPTACLE NONE LCP1 31 BREAKROOM RECEPTACLED TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE LCP1 32 BREAKROOM RECEPTACLED TIMECLOCK/OVERRIDE SWITCH RECEPTACLE NONE 1 LCP1 33 SPARE LCP1 34 SPARE LCP1 35 SPARE EA LCP1 36 SPARE LCP1 37 SPARE LCP1 38 SPARE LCP1 39 SPARE LCP1 40 ISPARE LCP1 41 SPARE LCP1 42 SPARE LCP1 43 SPARE LCP1 44 SPARE LCP1 45 SPARE LCP1 46 SPARE LCP1 1 47 ISPARE LCP1 1 48 ISPARE To additional wallstations (See plans for locations) (Offices area) To additional wallstations (See plans for locations) (Shop Area) GDS-ITL6-W I I GD;Bu e — ontton Whirol tation GDS-1 TLB-W 1 Bu ton Whit GDS — ontrol Sation To additional wallstations (See plans for locations) foti-•. pw a-1 CONTROL PANEL SCHEDULE'LCP2' (Pursuit Boat Works) - 277V Panel Relay Area Type Control Type Load Description Dimming LCP2 1 UPHOLSTERY C1&CIE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 2 ELECTRICAL C1&CIE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 3 ASSEMBLY Cl&CIE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 4 ASSEMBLY C1 &C1E TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 5 ASSEMBLY Cl&CIE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 6 ASSEMBLY Cl&CIE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 7 ASSEMBLY Cl&CIE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 8 ASSEMBLY Cl&C1E TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 9 ASSEMBLY C1&C1E TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 10 ASSEMBLY C1&C1E TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 11 ASSEMBLY C1&CIE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 12 ASSEMBLY Cl&CIE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 13 MILLSHOP C1&CIE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 14 MILLSHOP C1&CIE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP2 15 SPARE LCP2 16 SPARE LCP2 17 SPARE LCP2 18 SPARE LCP2 19 SPARE LCP2 20 SPARE LCP2 21 SPARE LCP2 22 SPARE LCP2 23 SPARE LCP2 24 SPARE CONTROL PANEL SCHEDULE'LCP3' (Pursuit Boat Works) -277V Panel Relay Area Type Control Type Laad Description Dimming LCP3 1 STOCKROOM Cl TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 2 STOCKROOM CIE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 3 GLASS ROOM C1 TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 4 GLASS ROOM C1E TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 5 SPARE C TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 6 LAMINATION05 C&CE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 7 LAMINATION EIS C&CE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 8 LAMINATION05 C&CE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 9 LAMINATION05 C&CE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 10 LAMINATION05 C&CE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 11 LAMINATION05 C&CE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 12 LAMINATION05 C&CE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 13 LAMINATION05 C&CE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 14 LAMINATION05 C&CE TIMECLOCK/OVERRIDE SWITCH LED NONE LCP3 15 SPARE LCP3 16 SPARE LCP3 17 1 SPARE SPARE SPARE SPARE RLCP320 SPARE SPARE SPARE SPARE I©\ LOW -VOLTAGE OCC SENSORS CIRCUITS: 1. OFF. 10 2. OFF. 11 3. OFF. 12 4. OPEN OFFICE 09 5. BREAK ROOM 17 6. CAFE 16 NOTES 1 THIS ONE -LINE DRAWING IS FOR CONCEPT ONLY. EVERY WIRE IS NOT SHOWN. WIRE ACCORDING TO THE PRODUCT INSTALLATION/WIRING INSTRUCTIONS. 2 REFER TO PLANS FOR LOCATIONS, SIZE, AND QUANTITY. 3 REFER TO ALL MANUFACTURERS INSTALLATION INSTRUCTIONS FOR CORRECT WIRING INFORMATION CABLES ❑ RS232 RS-232 CABLE (6 FEET), PROVIDED WITH PRODUCT p CAN USE EATON LIGHTING SYSTEMS LCCNP NON -PLENUM CABLE OR LCCP PLENUM CABLE. 6 LV3 LOW VOLTAGE INPUT WIRE - #18 AWG, 3 CONDUCTOR WIRE O RS485 RS-485 NETWORK CABLE, COOPER GG9841(NON PLENUM), COOPER GG89841(PLENUM) OR EQUIVALENT A, Project: FROP05ED MANUFACTURING DUILDING FOR FUR5UIT 50AT5 5901 5T. LUCIE P LVD. FOOT FIERCE, FLORIDA Key Plan <No STATE OF 'Au ZZ ✓✓✓/��/S� ON A� A��X��� f55ue5: No.: Date: De5criptior: A. 7112/19 1311) 5ET B. 7/18/19 PEKMITSET 1 C. 9113119 CONTRACTOR REV151ON5 D. 10/02/19 V.E. REVISION 3 A.rchiteet: DONADIO & Associates, Architects P.A. W9 Mh SWW1 vu"' Iicwh, I-l-'—WA .1'e1.772.791.2929 F.. 772.562.WAA) vw.�iwmJio-un'hcum Liecn,a No. AAIX M1% CohSultart anoommmu RL inf:§L 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 Drawing Tr, e': LIGHING GONTKOL5 & SCHEDULE5 Job North REVIEWED FOR CODE COMPLIANCE e� ST. LUCIE COU14TY BOCC Drn: Drawing ?Ile: NL Chd: XREE P11=: DL Pro ec; No.: Plot 9k: 2015-42 5k t No.: Cer;. No.: Date 5°fined: `-" —21 ME m J Z n U PANELBOARD S('HEDULE'H1' ... 02® N ® 2 • .. 8 mIW-mm m mom m MEN/��E r�• ���■� MINI■■■■[X�F■■ �!.■■■■� ■■E mr;n7 ■■■■■■� �M�a [f■iJ% E7 maw p-mlMEN �� MEMEl ���■�MEN ■■■■IN■n MINI MINI MIN■■■■■■ ■■�E13F7■■■ ■■■�WFM ONE SEEM MENE NI M IMEo■■■gym MINI MINI mm■■ DES■■■■� ■ M SIEM.MI■ IME IMIM■EINIMM MINIM■■■ ■IM� MMIN ■■■�ET-M mm MINI MMm ETIM■■■� 0101<0©0m MINI mm©m �mn�■m MINE■.■m MINI m.■E■■m ■■EMI■�E■■ MINI MINI MINI mmm ���■� m�� m©mom Fmmm �=�.� ■■■■..� ,.■■■.� ■■��� ��z .,RM., 1Omm .,��■» EM�� : m©■�® MINI wmm �Em�■= ■■.... MINI MINI MINI la■■■■■m ..�■�� ��EM .,gym® omM .,��■� cm EMI t0©mm MEMM" 0�■■■E■■ MINI �mu�■m ■■■■MINIM o.■■■■� ■■�■�� MINI MINI MINI ��� MEM&Mm©mm r�m ®�� ���■� ©®© m . • IMMIN9MENNENM ��■�■NI■ NINIE■■■© o.■■■■�� ■■� • � MINI MINI ■ MILL SHOP DUST COLLECTOR pmMMM"rm', NINI■■�o-m ■,�r�m ®�� ��� .. I��■� , . • . . • v■■om om■■ mv�� MINI■®■■■■r•■■■■■�■■■■■■m m■■■■■ ■■EMI■■INtNINIE ��� • • ®�® MINI■■■■■■■ • DEMAND TOTAL DEMAND AMPS SUB-TOtAL vA MEMNON PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ❑120/208 30,4W ❑120/240 30,4W ■277/480 30,4W BUS AMPS ❑100A E400A ❑200A ❑600A ❑225A ❑--A MAIN DEVICE EMAIN LUGS ONLY ❑__A CIRCUIT BREAKER ❑_--V FUSED SNATCH ENCLOSURE ❑FLUSH ESURFACE ENEMA 1 ❑HINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL ■PAINTED STEEL ■NAMEPLATE BRANCH POLES ❑12 ❑36 Ole ❑42 024 E60 BRANCH DEVICES ECIRCUIT BREAKERS ❑FUSES ❑_TO BE GFCI BREAKERS ❑LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ❑10,000A ❑30,000A ■65,000A 014,000A ❑42,000A ❑100,000A 022,000A ❑50,000A ❑_,000A ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES Q1 Q Q 4Q I@ NEUTRAL BUS ❑50% ❑2000PPER OX E100% ❑_%❑ALUMINUM BUS MATERIAL ■ 1EGROUND BUS REQUIRED ❑ PANELS IN PARALLEL 10 THROUGH FEED LUGS REWIRED PANELBOARD SCHEDiTLE'HA.' LOAD DESCRIPTION ■� .:. ��� ■■■■■■e MI'in MINI1nMm IN■■■OM ■■■� •:• SEE■ •:. WH��m MENOMI EEME■N M■ MINInm© ©mm�� ■■E■■■n momomm E■■■IMKM■■■ MGM m■a© MMOM 17IN■E■IM■E■ ■■■■IM MINI■ ■�■�E� �Ea�M MINI mNIaEa rm�■ E M MINI '■ E�E■■E■IM ■>tE70[G1 MNEMm ■MIfE MMMI� MOM NOMINEE ■■■■■■m MINI■■■■ ■■�w-rm� MINI MINI MINI MINI MINI ■■■■■■E� r�r�w� mEE■ /EE MINEE 7 �� ■IN■■mm mm■■ ■�E=� �EE■IM■E■ ■■■■■■�a �1INIM■■■M MINI■■■®� ■�■� ME■MM mEUMM KEENNESS!■�ElMOM MERE© 0 �� �E�■■■■■EMI ■■■■■■® MINI MINI MINI MINI MINI MINI in MINI MINI m.■■E■■EMI ■■■■NIEE■ ■MMENSE= "ENIlE® m�� E■■��E �it'DD■■■■■■ • - ©Elmk37 kT1■-vENI • E>•m��■■■ ■�����IMMIMMINNIMANM aa.■■■m� ■■��■■■ ■■■■ N E NENII�CSI mOmm EM��Mm ■�� • , . ©©mm M. , . ■��■■■■■�MM1■■■■MINIM MINIM■■ENE■■ ■■E■■■� ■E■NON= 113 minim m■ m m■� 1=�� • i ©M .8 . mmEl .. EEtff r m, IMME IMME ■■■m■■■�� ■■■■MINIM MINI �■ MINI ■ MM■■■■■■MMI ■■■��� �� EaEMIlE® ME NEE ��� -- . �■■gym mm© . mv�� �■�■�■ ■IN■■MMMm MO■■■■ ■■■■■o �E■gym m�r� ■',��■� I��� Lm�• 1�• ��� ■■■SEM■■■ TOTAL DEMAND VA -TOTAL VA TOTAL DEMAND AMPS SUB PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE 0120/208 30,4W ❑120/240 30,4W 0277/480 30,4W BUS AMPS ❑100A 0400A 0200A 0600A 0225A E1200A MAIN DEVICE EMAIN LUGS ONLY ❑_A CIRCUIT BREAKER ❑_A FUSED SNATCH ENCLOSURE ❑FLUSH ■SURFACE ENEMA 1 ❑HINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL EPAINTED STEEL JENAMEPLATE BRANCH POLES 012 036 018 042 024 E60 BRANCH DEVICES ECIRCUIT BREAKERS ❑FUSES ❑__TO BE GFCI BREAKERS ❑LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A E30,000A 065,000A ❑14,000A 042,000A ❑100,000A 022.DOOA 050,000A ❑__OOOA ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES O 03 TO NEUTRAL BUS 050% ❑200% E100% ❑ ' BUS MATERIAL ECOPPER ❑ALUMINUM INGROLIND BUS REQUIRED ❑ PANELS IN PARALLEL 10 THROUGH FEED LUGS REQUIRED PANELBOARD SCH EDLTLE 'H7' CONNECTED VOLTAMPS NMRES :BUS WRES CONNECTED VOLTAMPS A0 80 co LOAD DESCRIPTION AWG AMPS Y ABC x AMPS POLE LOAD DESCRIPTION AWG A0 B0 CO IF -----------FIE IR-TOTAL VA TOTAL CONNECTED AMPS 63 165 J. ------------------- 120/208 30,4W ❑100A 0400A EMAIN LUGS ONLY 120/240 30,4W 0200A 10225A 0600A ❑__A CIRCUIT BREAKER 10--A 277/480 30,4W ❑_A FUSED SNATCH ERRUPTING RATING (AIC SYM) 10,000A 03O,000A E65,000A 14,000A 042,000A ❑t0,OD0A 22,000A 050,000A 0.-,000A SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NEUTRAL U ❑2 E100% ❑ BUS MATERIAL ECOPPER ❑ALUMINUM E GROUND BUS REQUIRED PANELS IN PARALLEL ❑ THROUGH FEED LUGS REWIRED ❑ FLUSH ■ SURFACE ENEMA 1 ❑HINGED DOOR ❑KEYED LATCH ❑DDOR- IN -DOOR ❑ STAfU * S STEEL EPAINTEI) STEEL ENAMEF'I-ATE MINI MINI■ '®MINI■.■■ MINI■■■■© �■■■■.■■ ■■■■■�� MINI '• ���.� MINI■■■■■ m■■■■.� ■■���■. ��� ■a�■am MINI MINI M�E;a ���� ��� : - m©mm mm©: - m��■■■ MINI EMI■�■�.� ......® M■■■■E■� ..■��� NIJ E7m � MINI M G M ■7�E■■�:Zi7 momm MINI MINI m®© ... ®��■� ���.� ......® �....�����..�■ MEN ■� �� .' , , ■.©■�� MINI®■. MINI - ®��.. ���■�����■■■■■■ MIN■■■gym ■■���. MINI ��� ■,�� mmM nr*Tl�� ■.■■■gym mm■■ . :., m��■.I ;; MINI MINI ■ MNON ��■a® m■ar� ���� m■■m® om■■ • - :.. � ���■■. MINI ���■�� ■■E■■■m 0■■■■�����■■■■■�■� ��® ���m ®■ate ��■�� ;; MINI MINI MINI ■■ MINI MINI ■ ��� • • = m■■■•gym ©■�© . • :' ,..- o • • �■■■ ���■�� ■■■■■■m o.■■�.■.��■■■■■ �■ ��� ��r■,m o�Ea ��� .. . • �� m©■am m■�■■ - : • ...• o • • �� .. ■�■�■■ MINI■■■■® ®■■■■.����■■■� �■ �� •• l7ENIl�® ®�ENI ��� •. � .. �� m■■®m oo© mo��■ .. �■�� ■■■■■■m m.■■■■ ■■�o■IN� �� • • l7EaENIEm MENEMEm �■�EE■■� um PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ❑l20/208 30,4W ❑120/240 30,4W E277/480 30,4W BUS AMPS ❑100A E400A ❑200A ❑600A ❑225A ❑_JA MAIN DEVICE ■MAIN LUGS ONLY ❑__A CIRCUIT BREAKER ❑__A FUSED SNATCH ENCLOSURE ❑ FLU SH ESURFACE ENEMA 1 ❑HINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL EPAINTED STEEL ■NAMEPLATE BRANCH POLES ❑12 036 018 042 024 ■60 BRANCH DEVICES ECIRCUIT BREAKERS ❑FUSES ❑_TO BE GFCI BREAKERS ❑LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A ❑30,000A E65,000A ❑14,000A ❑42,000A ❑100,000A ❑22,000A ❑50,000A 0___,000A ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES Q 04 03 4Q OS NEUTRAL BUS ❑50% ❑200% ■100% ❑_ BUS MATERIAL ■COPPER ❑ALUMINUM ■GROUND BUS REQUIRED ❑ -----PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED LOAD DESCRIPTION LOAD DESCRIPTION MINI MINI �RLIL" ■■■■■■e e.■■■�� ■■� ■� SIEME ■a■am mom rar■rrim 0:10 MINI MINI mm■■ • =E=� ����� ■■■■■■n m.■■■�� ■■E■■�MI�IN ■NEMONIC= MGM E7■■■� ET";ENEEmg Imm Io■■mm MINI MINI mm© ■IN�� MOM ■■■■MINIM m■1■■■�■IM ■■■■■ �, �■�� ■a�r■,m M■a� ROOMINESS �� �� o■■mm mm■■ • ���■■� ■■■■MINIM '■ m.■■■■■■■ ■■■��� MINI MINI MINI MEMEON ��� m■a� ��� �■�■� • • ■IN©om m■�■■ •' o��� �v-rm ■■mm ■■■■■■Fi7 M.■■■MM ■■■�■�■� ��ET.10 mINUMENI K',Ym MOM MOM rerm WA. ■■mm MINI MINI �mm��� ■■■■MINIM m.■■■NI■m ■■■���■, ��� E■��m o■IN� �■�■� �■■NI■EMI _ �E7mEi7 Mm©: _ �� MINI MINI ■■■■■■■■� is on MINI ���■■� ■■■■■■k7 m■■■■MME■ ■■■■■�� ■■■E■NI� EaENIlEm ®��ENI MEE■MI■■ r ��� : �■■mm om© RM MEN ■■■�■■■�� ■■■■■■[ ■■■■■�� ��© �Ea■am o�� ��■� ► ., �� ., m■IMmc� mm■IM ®���■ ■� �� MINI■■■■® ®.■■■�� ■■��■� �� .. EarAMUMm 93MUMM ONE • ■©mmm ■ MMMMMMm EM■o.EMIN �mm�mm ■■■■■■m m.■■■■ ■■�■o• ��Da ELIMENIE,Em MEMEM EaNOMINEEO PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE 0120/208 30,4W ❑120/240 30,4W E277/480 30,4W BUS AMPS ❑100A 0400A ❑200A ■600A 0225A ❑_A MAIN DEVICE EMAIN LUGS ONLY ❑_A CIRCUIT BREAKER ❑_A FUSED SNATCH ENCLOSURE ❑FLUSH ESURFACE ENEMA 1 ❑HINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAILESS STEEL j EPAINTED STEEL I ENAMEPLATE BRANCH POLES ❑12 036 018 ❑42 024 E60 BRANCH DEVICES ECIRCUIT BREAKERS ❑FUSES ❑_TO BE GFCI BREAKERS 10LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A ❑30,000A ■65,000A 014,000A ❑42,000A ❑100,000A ❑22,000A ❑50,000A ❑_OOOA ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES 01 Q 40 sO NEUTRAL BUS 0502 ❑200% E100% ❑ BUS MATERIAL ECOPPER ❑ALUMINUM EGROUND BUS REQUIRED ❑ PANELS IN PARALLEL ❑ THROUGH FEED LUGS REWIRED PANELBOARD SCHEDTTLE'H8' CONNECTED VOLTAMPS LOAD DESCRIPTION - LCP2-1 CUFFS AWG POI£S AMPS - 20 r'• x BUSS A B C w x P 2 AMPS - - 20 PO.F - t LOAD DESCRIPTION - - - - - - - ------- _ _ _ _ _ _ LCP2-13 -- - - - - - WRES AWG - - 10 CONNECTED A0 - - 3080 VOLTAMP5 B0 _� Co A0 - 2256 Bo : < - - C0 < _ - - - 12 - t 1 H F r r (-10 - I- 2256 LCP2-2 12 1 20 4 20 1 LCP2-14 70 2702 2316 LCP2-3 10 1 20 I 20 1 ASSEMBLY N L 10 1930 2702 LCP2-4 10 1 20 7 8 20 1 ASSEMBLY NA 10 1930 2316 LCP2-5 10 1 20 20 1 ML,LStOP Nit 10 2256 2702 LCP2-6 10 1 20 1 1 SPACE 2702 LCP2-7 10 1 20 14 -------------------'------- IS 1 2 1 1 TuN HOIST tz SOU 2702 LCP2-8 10 1 20 2702 LCP2-9 1 10 1 20 11711,--+rgi 2702 LCP2-10 10 1 20 20 500 2702 LCP2-11 10 1 20 21, 22 500 y I I I n TOTAL DEMAND VA 11500 1500 1500 TOTAL DEMAND AMPS SUB -TOTAL VA_ PANELBOARD FEATURES I 3 I F Iy I I I 15g! 11826 0 17969 '1677fi TOTAL CONNECTED VA 23770 23427 119206 SUB -_TOTAL VA TOTAL CONNECTED AMPS 86 85 69 I 3 PANELBOARD RATINGS T 11601 J' I y J' I y I I I 1 TOTAL DEMAND VA E5510 15458-1 2 TOTAL DEMAND AMPS SJ6-iOint. Jn 3 PANELBOARD FEATURES BRANCH POLES 012 036 ❑18 042 024 ■60 BRANCH DEVICES ■ORCUIT BREAKERS ❑FUSES VOLTAGE 0120/20B 30,4W 0120/240 30,4W ■277/480 30,4W BUS AMPS ❑100A ❑400A ❑200A 0600A ■225A ❑__ A MAIN DEVICE EMAIN LUGS ONLY ❑__A CIRCUIT BREAKER ❑__A FUSED SWITCH ENCLOSURE ❑ FLU SH ESURFACE ENEMA 1 ❑HINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL EPAINTED STEEL IS NAMEPLATE BRANCH POLES 012 036 Ole ❑42 024 ■60 BRANCH DEVICES ECIRCUIT BREAKERS ❑FUSES ❑_TO BE GFCI BREAKERS ❑_TO BE GFCI BREAKERS ❑LOAD CENTER PERMITTED ❑LOAD CENTER PERMITTED NOTES 1D 02 03 ® O INTERRUPTING RATING (AIC SYM) ❑IO,000A E30,000A ❑65,000A 014,000A 042,000A 0100,000A 022,000A 050,000A ❑_000A ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES Qt 02 03 4Q O NEUTRAL BUS 1150% ❑200% 01100% ❑ _ BUS MATERIAL ■COPPER ❑ALUMINUM (AGROUND BUS REQUIRED ❑ PANELS IN PARALLEL 11 1 THROUGH FEED LUGS REQUIRED PANELBOARD SCHED1JLF.'H3' CONNECTED VOLTAMPS LOAD DESCRIPTION HIRES AWG AMPS ' x BUS A B C x U AMPS POLES LOAD DESCRIPTION WRES AWG CONNECTED VOLTAMPS Am 60 Co A0 B0 C0 -jA.1A,1 1 2 150 3 AIR COMPRESSOR 2 75HP 1 0 26592 3 4 26592 _I s � -y-1 y P------------------•--ass, �. 7 d .� MR uR ¢h I IL ISui to 1ss7 LLLU�� Oe 48795 47395 47675 TOTAL CONNECTED VA 80401 79001 79281 n TOTAL DEMAND VA 31608 31608 31606 TOTAL CONNECTED AMP.; 290 285 286 3� TOTAL DEMAND AMPS a,'R-,Tnvi "e PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ❑120/208 30,4W ❑120/240 30,4W M277/480 30,4W BUS AMPS ❑IOOA ❑400A ❑200A E600A 0225A ❑_Jr MAIN DEVICE EMAIN LUGS ONLY ❑--A CIRCUIT BREAKER ❑_A FUSED SNATCH ENCLOSURE ❑FLUSH ■SURFACE ENEMA 1 ❑HINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL ■PAINTED STEEL ■NAMEPLATE BRANCH POLES 012 036 018 042 024 E60 BRANCH DEVICES ECIRCUIT BREAKERS ❑FUSES ❑_TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A E30,000A 065,000A ❑14,000A 042,000A 0100,000A 022,000A ❑50,000A ❑_,000A ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES 01 Q3 SO NEUTRAL BUS 050% 0200% ■1DOX ❑ BUS MATERIAL ECOPPER ❑ALUMINUM ■GROUND BUS REQUIRED ❑_-_PANELS IN PARALLEL ❑ THROUGH FEED LUGS REWIRED PANELBOARD SCHEDTTLE'Hfi CONNECTED VOLTAMPS LOAD DESCRIPTION CURES AMPS BUS AMPS POLES LOAD DESCRIPTION YM1ES CONNECTED VOLTAMPS AA B0 Cm AWG yS A B C AWG A0 80 Co tI US,) 131 USJ 131 U851 TOTAL CONNECTED VA SUB -TOTAL VA TOTAL CONNECTED AMPS TOTAL DEMAND VA TOTAL DEMAND AMPS yIb-It)I H7 VA PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE 0120/208 30,4W ❑120/240 30,4W M277/480 30,401 BUS AMPS 0100A E400A ❑200A ❑600A 0225A ❑_A MAIN DEVICE ■MAIN LUGS ONLY ❑--A CIRCUIT BREAKER ❑--A FUSED SNATCH ENCLOSURE ❑FLUSH ■SURFACE ENEMA 1 ❑HINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL ■PAINTED STEEL ENAMEPLATE BRANCH POLES 012 036 Ole 042 024 E60 BRANCH DEVICES ECIRCUIT BREAKERS ❑FUSES 0-TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A 030,000A ■65,000A 014,000A 042,000A 0100,000A 022,000A 050,000A ❑_OOOA ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES 0 4Q (3 NEUTRAL BUS 05CX 0200% E100% 0_7 BUS MATERIAL ■COPPER ❑ALUMINUM ■GROUND BUS REQUIRED ❑___PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED PANELBOARD SCHEDTTLE'HAC CONNECTED VOLTAMPS LOAD DESCRIPTION AWG AMPS x BUS E B C •I� F AMPS POLES LOAD DESCRIPTION YAFES AWG CONNECTED VOLTAMPS p0 80 Co AO B0 CO U •23/B !J& TOTAL CONNECTED VA 78989 78989 7B98! Sti18-iOTinL .A T TOTAL CONNECTED AMPS 285 285 285 PANELBOARD RATINGS VOLTAGE BUS AMPS MAIN DEVICE 3120/208 30,4W ❑100A E400A ■MAIN LUGS ONLY 3120/240 30,4W ❑200A 0600A ❑_-A CIRCUIT BREAKER 1277/480 30,4W 0225A ❑_A ❑_...A FUSED SWITCH VTERRUPTING RATING (AIC SYM) ❑SERVICE ENTRANCE RATED NEUTRAL BUS BUS MATERIAL 310,000A ❑30,000A E65,000A 314,000A 042,000A ❑1DO,000A 050% 02DO% ■COPPER 322,000A 050,000A ❑_OOOA E1001 ❑_ ❑ALUMINUM ]SERIES RATING PERMITTED EGROUNO BUS REQUIRED 3 PANELS IN PARALLEL 10 THROUGH FEED IIIGS REQUIRED TOTAL DEMAND VA 1366111366111366 _ TOTAL DEMAND AMPS SJo-TOTAL VIA- - - - - - - - PANELBOARD FEATURES - - - - - - - - - - - - ENCLOSURE BRANCH POLES BRANCH DEVICES ❑FLUSH 012 036 ECIRCUIT BREAKERS ❑FUSES ❑ SURFACE ❑ 18 ❑ 42 ❑ _TO BE GFCI BREAKERS ❑NEMA _ 024 ■90 ❑ LOAD CENTER PERMITTED ❑HINGED DOOR NOTES ❑KEYED LATCH 0 ❑DOOR -IN -DOOR ❑STAINLESS STEEL 03 ❑PAINTED STEEL D ■NAMEPLATE O Project: FKOF05ED MANUFACTURING P UILdING FOK FURGIUIT BOATS 5901 5T. LUCIE 5 LVD. FORT FIERCE, FLORIDA Key Plan S % , ST Te IF i ev `BSI eC N N- \\\ '1011111\\\\ 155Ue6: No.: Date: Description: A. 7/12/19 BID 5ET B. 7/15/19 PERMIT 5ET 1 C. 9/13./19 CONTRACTOR REV1510N5 2 D. 10/02/19 V.E. REVI510N 3 ArchVw.t: DONADIO & Associates, Architects P.A. fi119 171h \P.ti1 Venn Beuu h, I•L 329M1 Tc1.772.7 2929 I+ux.772.962.WAX) ,vrvrv.dm udwr umlw m Lw.,, \u..AAIXX=A Comwltarrt: Lwa CAROinF1L ".1nEERtnL FR55r c!FIT 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengiiieers.com CA LIC. 31555 Urawiag Title: FANEL130AI2D 5CHEDULE5 JobNO.tl REVIEWEB Foi_ CODE COMPLIANCE e ST. LUCIE COUNTY BOCC Drn: Drawing File: N_ Cho: XKEF Re: DL Project No.: P.ot FCe: 20IF5,42 5hee; No: Cert. No.: )ate 511 E -22 AO 1 80 1 CO To 4B80 5 UB _TOTAL VA PANELBOARD SCHEDTTIE'Ll' PANELBOARD SCHEDLJLE'U' �,. YWtES CONNECTED VOLTAMPS CONNECTED VOLTAMPS LOAD DESCRIPTION WIRES AMPS r BUS AMPS LOAD DESCRIPTION AWGOAD DESCRIPTION gyre AMPS U 6B c~xi AMPSPOES LOAD DESCRIPTION pyyG x A B C _ Am Bm COCm Am 60 C0 TOTAL CONNECTED VA 17BUO TOTAL CONNECTED AMPS fi5 TOTAL DEMAND VA 41 Iuu Zao< '� Z TOTAL DEMAND AMPS SUB- TOTAI VA PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ■120/208 30,4W 0120/240 30,4W ❑277/480 30,4W BUS AMPS ❑100A 0400A ■200A 06DOA 0225A ❑_A MAIN DEVICE MMAIN LUGS ONLY 0_11 CIRCUIT BREAKER ❑_-, FUSED SWITCH ENCLOSURE ❑FLUSH ■SURFACE ENEMA 1 MHINGED DOOR ❑KEYED LATCH POLES BRANCH PO 012 036 018 ■42 024 ❑- RANCH 8 DEVICES ECIRCUIT BREAKERS ❑FUG ■17,21 TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ❑10000A 030000A 065000A ❑SERVICE ENTRANCE RATED NOTES Q LOCKABLE BREAKER NEUTRAL BUS BUS MATERIAL 014,000A 042,000A ❑100,000A 050% ❑2DO$ ECOPPER ❑DOOR -IN -DOOR E22,000A 050,000A 0--000A E100% 0_-7 ❑ALUMINUM El STAINLESS STEEL ❑SERIES RATING PERMITTED EGROUND BUS REWIRED ■PAINTED STEEL ❑ PANELS IN PARALLEL ❑ THROUGH FEED LUGS REWIRED ENAMEPLATE PANELBOARD SCHEDtJLE'IA' CONNECTED VOLTAMPS LOAD DESCRIPTION G POLES AMPS 69 "" AMPS LOAD DESCRIPTION YES AWG CONNECTED VOLTAMPS A0 80 CO CO A0 Bm 720 15TOCIC RN RECEPS _I 12 I 1 I 2D I 1 I 2u i rlra rinrtx rnncL w •2 I -Linn Sli>dc ME W-- & DOCK LB 12 1 I 20 13 I d _ TO - EI cC7 - aF- - - - - - - - 2� - - '�6� IL220 , 4160 1 F20C , TOTAL CONNECTED V,A @rrn � 614C 73EG 1�- -� 1 I TOTAL DEMAND VA 1 2300 1 111Bu 1 2 TOTAL DEMAND AMPS SUB -TOTAL VA J M-IUInL Vn .... ..� ........-... ...... - _- - PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ■120/208 30.4W 0120/240 30,4W 0277/480 30,4W BUS AMPS ❑1GOA ❑400A E200A 0600A 0225A ❑_A MAIN DEVICE EMAIN LUGS ONLY ❑_A CIRCUIT BREAKER ❑_A FUSED SWITCH ENCLOSURE ❑FLUSH ESURFACE ENEMA 1 EHINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR [I STAINLESS STEEL ■PAINTED STEEL ■NAMEPLATE BRANCH POLES 012 ❑36 018 E42 024 ❑- BRANCH DEVICES ECIRCUIT BREAKERS []FUSES 0--TO BE GFCI BREAKERS ❑LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A 030,000A 065,000A ❑14,000A 042,000A ❑100,000A E22,000A ❑50,000A ❑--OOOA ❑SERIES RATING PERMITTED []SERVICE ENTRANCE RATED NOTES Q LOCKABLE BREAKER NEUTRAL BUS ❑50% 02D0$ E100% ❑--X BUS MATERIAL ■COPPER ❑ALUMINUM EGROUND BUS REQUIRED ❑- PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED PANELBOARD SCHEDtJLE'LT CONNECTED VOLTAMPS � WRES CONNECTED VCILTAMPS Am B6 CP LOAD DESCRIPTION pyyG POLES AMPS x BUS x AMPS POLES LOAD DESCRIPTION AWG p0 Bm C0 , TOTAL CONNECTED VA IISO _ TOTAL CONNECTED AM'5. 1: TOTAL DEMAND AMPS SUB -TOTAL VA PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE M120/208 30,4W ❑120/240 30,4W 0277/480 30,4W BUS AMPS ❑100A ❑400A ❑200A ❑600A ■225A ❑--A MAIN DEVICE ■MAIN LUGS ONLY ❑_A CIRCUIT BREAKER ❑_-A FUSED SWATCH ENCLOSURE EFLUSH ❑SURFACE ENEMA 1 EHINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESSSTEE EPAINTED STEEL ENAMEPLATE BRANCH POLES ❑12 ❑36 ❑18 E42 024 ❑- BRANCH DEVICES ECIRCUIT BREAKERS ❑FUSES 0--TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ❑10,000A ❑30,000A ❑65,000A ❑14,000A 042,000A 0100,000A E22,000A ❑50,000A ❑-,000A ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES Q Q 3O O @ NEUTRAL BUS 050% ❑200$ Et00% ❑--%❑ALUMINUM BUS MATERIAL ECOPPER EGROUND BUS REQUIRED ❑ PANELS IN PARALLEL ❑ THROUGH FEED LUGS REWIRED -� SPafiE f� c r _ _ _ _ _ _ _I I 1 4 0 15r WIRES CONNECTED VDLTAMI AWG A0 60 C0 4320 478 340 TOTAL CONNECTED VA 9320 10780 113403 TOTAL DEMAND VA 1,OUV I ouW I auuv3 SUB-fOT_AL_ VM TOTAL CONNECTED AMP: 78 90 95 TOTAL DEMAND AMPS SUB _TOTAL - PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE 0120/208 30,4W 0120/240 30,4W 0277/450 30,4W BUS AMPS ❑t00A 0400A ■200A 0600A 0225A ❑_A MAIN DEVICE EMAIN LUGS ONLY ❑__A CIRCUIT BREAKER ❑_A FUSED SWITCH ENCLOSURE ❑FLUSH ■SURFACE ENEMA 1 ®HINGED DOOR []KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL ■PAINTED STEEL ENAMEPLATE BRANCH POLES 012 ❑36 018 E42 ❑24 ❑- BRANCH DEVICES ECIRCUIT BREAKERS ❑FUSES ❑-TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A 030,000A 065,000A 014,000A ❑42,000A ❑100,000A 022.000A ❑50,000A 0--000A ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES O 04 OO NEUTRAL BUS 050% ❑200% 01007 ❑- BUS MATERIAL ECOPPER ❑ALUMINUM EGROUND BUS REQUIRED ❑ 3ANILS IN PARALLEL ❑THROUGH FEED LUGS REQUIRED PANELBOARD SCHEDULE'L5' PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE 0120/208 30,4W 0120/240 30,4W 0277/480 30,4W BUS AMPS 0100A ❑400A E200A ❑600A 0225A 0--A MAIN DEVICE EMAIN LUGS ONLY ❑_-_A CIRCUIT BREAKER ❑-A FUSED SNATCH ENCLOSURE EFLUSH ❑SURFACE ENEMA 1 EHINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL ■PAINTED STEEL ENAMEPLATE BRANCH POLES 012 ❑36 018 E42 ❑24 ❑- BRANCH DEVICES ECIRCUIT BREAKERS [I FUSES []_TO BE GFCI BREAKERS ❑LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ■IO,000A ❑30,000A 065,000A ❑14,000A 042,000A ❑100,000A ❑22,000A 050,000A ❑--000A ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES 0 (2 0 OO NEUTRAL BUS 050% ❑200% E1007 ❑ BUS MATERIAL ■COPPER []ALUMINUM EGROUND BUS INQUIRED ❑ PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED PANELBOARD SCHEDLTI.E18' PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE E120/208 30,4W 0120/240 30,4W 0277/480 30,4W BUS AMPS ❑100A 0400A ■200A ❑600A 0225A 0--4 MAIN DEVICE EMAIN LUGS ONLY ❑---A CIRCUIT BREAKER ❑__A FUSED SWATCH ENCLOSURE EFLUSH ❑SURFACE ENEMA 1 EHINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL EPAINTED STEEL ENAMEPLATE BRANCH POLES ❑12 036 018 042 024 ❑- BRANCH DEVICES ECIRCUIT BREAKERS ❑FUSES 0--TO BE GFCI BREAKERS ]LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) E10,000A 030,000A ❑65,000A 042,000A 0100,000A ❑22,000A ❑50,000A ❑-,CODA ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES (1)❑I*,000A 0 O OS NEUTRAL BUS 2000PPER ❑50% ❑0$ ■100% ❑ BUS MATERIAL E ❑ALUMINUM EGROUND BUS REQUIRED ❑------ PANELS IN PARALLEL ❑THROUGH FEED LUGS REWIRED PANELBOARD SCHEDLJLE'L3' CONNECTED VOLTAMPS µmg BUS WIRES CONNECTED VOLTAMP LOAD DESCRIPTION AWG (ALS AMPS A B C AMPS FOES LOAD DESCRIPTION AWG Am Bo co Am Bm Cm 72pI ASSEMBLY RECEPS 12 9 20 20 1 CPRESSOR RM RECEPS ON 12 720 720 ASSENBLY RECEPS 12 9 20 3 4 20 1 CONPRESSOR RM REC£PS 12 360 720 ASSENBLY RECEPS 12 1 20 5 F �0 CnMPRFaSAR RV W('SPS 12 -- ?5n - -..... .cmmry ornroc 19 , 90 7 -FRr - TO-1 1 rtSPARE ------------------ I I _ 3 372012520 12 SUO-TOTAL VA TOTAL CONNECTED VA ` r56' TOTAL CONNECTED AMP't- 4- TOTAL DEMAND VA TOTAL DEMAND AMPS Zj VA PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE E120/208 30,4W 0120/240 30,4W 0277/480 30,4W BUS AMPS ❑t00A ❑400A ■200A 0600A 0225A ❑_-A MAIN DEVICE []MAIN LUGS ONLY ■150A CIRCUIT BREAKER ❑_A FUSED SWITCH ENCLOSURE ❑ FLUSH ■SURFACE ENEMA 1 NHINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESSSIM ■PAINTED STEEL ENAMEPLATE BRANCH POLES 2 36 ❑ 1 ❑ 018 E42 ❑24 ❑- BRANCH DEVICES BREAKERS FUSES � CIRCUIT BREA ❑ ❑--TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,DOOA 030,000A 065,000A ❑14,000A 042,000A ❑100,000A ❑22,000A ❑50,000A ❑_-OOOA ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED NOTES 01 O 13 NEUTRAL BUS 050% ❑200% E1DO% ❑_%❑ALUMINUM BUS MATERIAL ECOPPER EGROUND BUS REQUIRED ❑ PANELS IN PARALLEL ❑ THROUGH FEED LUGS REWIRED PANELBOARD SCHEDiA,E'1-B PANELBOARD SCHEDULE'L9' ONNFCTED VOLTAMPS Am Bm Cm LOAD DESCRIPTION AWIGS AMPS x peB C x AMPS FOES LOAD DESCRIPTION ------------- -------------- ---------- - - -r-r -T.==- . �J3 ',o'.i s : TOTAL CONNECTED AMPIA 96 _I M I 8B PANELBOARD RATINGS VOLTAGE BUS AMPS MAIN DEVICE g120/208 30,4W ❑100A ❑400A EMAIN LUGS ONLY 3120/240 30,4W E200A [1600A ❑_- A CIRCUIT BREAKER ]277/480 30,4W 0225A ❑_ A ❑__A. FUSED SNATCH NTERRUPTING RATING (AIC SYM) ❑SERVICE ENTRANCE RATED NEUTRAL BUS I BUS MATERIAL ]t0.000A 030,000A ❑65,000A ]14,000A ❑42,000A ❑100,000A 050% 0200$ 1000PPER M22.000A 050.000A [1-,OGOA E100% ❑ ❑ALUMINUM EGROUND BUS REQUIRED ]SERIES RATING PERMITTED -I PANELS IN PARALLEL ❑ THROUGH FEED LUGS REWIRED CONNECTED VOLTAMPS A0 1 Bm 1 00 I I I I TOTAL DEMAND AMPS --I ; nL PANELBOARD FEATURES ENCLOSURE BRANCH POLES BRANCH DEVICES ❑FLUSH 012 ❑36 ECIRCUIT BREAKERS ❑FUSES ❑_TO BE GFCI BREAKERS ■SURFACE ❑18 ■42 El LOAD CENTER PERMITTED ENEMA 1 ❑24 ❑- NOTES ❑HINGED DOOR ❑ KEYED LATCH Q ❑DOOR -IN -DOOR ❑STAINLESS STEEL 03 ■PAINTED STEEL ENAMEPLATE O Project: FKOF05ED MANUFACTURING P UILDING FOR FUR51JIT BOAT5 5901 5T. LUCIE BLVD. FORT FIERCE, FLORIDA Key Flan 77 3 04: - 4l� 5� r g1 . NU a pi IONA%, s` I IL1�\a issues: No.: Date: Description: A. 7112/19 DID 5ET 5, 7/15119 PERMIT 5ET Al C. 9113/19 CONTfMTOR F.E111514 D. 10/02/19 V.E. R.EVI510N Architect: DONADIO & Associates, Architects P.A. NAJ 1701 SPm1 Vm, Bcxh,11.32'A TO 772.7432M 11.x'772.562FNAl www.,hmutfio-urJiwrtn L*.,,w So. .AA(Xm?T,Y Comwitart: ea I=RR oinRL 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 Drawing TP e: FANELB0ARI) 5CHEE)ULE5 Job No t REVIEWED FOR CODE COMPLIANCE e� '" T. LUCIE COUNTY SOCC Drn: Drawing =11e: NL Ch& XRE??Ile: DL Fro`ec, No.: Plot Flle: 2018-42 5heat No.: Gar - No.: E `°" r/�;r�) Dates°fined: 9'G'8."r,dl 6 An;v:A:2ro, A':r:Rl, L e. I. I, I 111 de?&JI. PANELBOARD SC"HFDIJLE 'L10' � Project: )NNECTED VO.TAMPS .m SNV WHB0ARD SCHEDULE HDPl SANTTCHBO ARD SCHEDIJLE'HDP2' WIRES BUS WIRES CCMYNECTED VOLTAMPS CONNECTED VOLTAMPS � m Ap Bp co LOAD DESCRIPTION WRES IXFS AMPS � AMPS POIFS LOAD DESCRIPTION WIRE$ BUS"RES CONNECTED VCILTAMPS CONNECTED VOLTANPS 3E A 8 C AWG ko Bp Co Ap Bp Cp LOAD DESCRIPTION AW AMPS � ABC C 1- AMPS P LOAD DESCRIPTION A Aa1 Bp CoAO Bp C0 LOAD DESCRIPTION ASS POLES AMPS � BUS r gMPS POLES LOAD DESCRIPTION AWG CONNECTED MDLTAMPS A 8 C i'f�Of�05ED - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ AO Bp Cp i00 AIR BREATHER CTRLR 10 1 20 1 - 2 20 1 EVM% -12 602 72743 PANELBOARD 'H1' 600 3 400 1 2 400 3 PANELSOARD 'H2' fi00 75445 227140 PANELBCARD 'H4' 3x 3 1200 7 2 600 3 PANELBOARD 'H5' 3x 106503 600 NR BREATHER CTRLR 10 1 20 20 i HAND DRYER 10 1440 72743 MCM 75445 227140 0� 906503 600 AIR BREATHER CTRLR ICI 1 20 5 6 20 1 HOSE CUTTER 12 1200 �?7.3 M`�" 5 6 75e,5 227140 MJ 3 6 My 1_06503 M /'�>U U 1=/��TU 12I N G S00 AIR BREATHER CTRLR 10 1 20 SPACE 1 8040E PANELBOARD 'H3' ssu J 600 7 500 3 TRANSFORMER T1 2x 6345E ! 592833 - - - PANELBOARD 'H6' - - - - - - - 800 3 400 7 8 200 3 PANELBOPRD 'HY 3 0 17514 960 TRUCK WELL SUMP PUMP 10 2 15 9 10 - --- - -- - -- - 7900E 250 i 97960 g U I L D 1 N G 960 79261 MC 9 10 MCM 64i05 59283 MCM 9 t0 1 11 1 Y i 62782'. 59283 _ 11 12 1716g `SPARE 1 20 13 4 r, 78989 PANEL 'HAC 600 3 400 13 4 225 3 PANELBOARD 'H8' 4 0i23770 F39912 TRANSFORMER T2 - 50U 3 350 13 14 200 3 PROVISION FOR RESIN BLDG I - 3 SPARE 1 20 15 16 v 78989 MCM 15 16 23427 19206 38343 c MCM 15 t - - - - C Op 'FAL` 1 18 78989I .. I IA 19 2 7MSION 3 40D '7 1A ----------------- -,-- -- --& 38593 17 18 1 22 21 2 1 PRONSK)N 3 400 21 2 3 SPACE' U U 1 T S A T5 4 --- - -- -- - '1 23 24 __.-. SPACE s 23 1 4, - -.---------- 1 1200 1 1560 1 1560 I� TOTAL CONNECTED VA 1&kd 3000 2760 TOTAL DEMAND VA 600 14-40 1200 Jiio-IvfiLLaA TOTAL CONNECTED 15 25 23 TOTAL DEMAND AMPS SUB -TOTAL VA 1 1 3 1im � - PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE E120/208 30,4W ❑120/240 30,4W BUS AMPS 01ODA 0400A E200A ❑600A MAIN DEVICE ■MAIN LUGS ONLY ❑_A CIRCUIT BREAKER ENCLOSURE ❑FLUSH ■SURFACE BRANCH POLES 012 036 018 E42 BRANCH DEVICES ■CIRCUIT BREAKERS []FUSES ❑--TO BE GFCI BREAKERS ❑277/480 30,4W 0225A ❑_A ❑_A FUSED SWITCH ENEMA 1 ❑HINGED DOOR ❑KEYED LATCH 024 ❑- ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A ❑30,000A 1_1165,000A ❑SERVICE ENTRANCE RATED NOTES 01 NEUTRAL BUS BUS MATERIAL 014,000A ❑42,000A 0100,000A ❑50% ❑ 200%❑ALUMINUM ■COPPER ❑DOOR -IN -DOOR Q 022,000A 050,000A ❑_,000A 0100% ❑ ❑STAINLESS SIR Q3 ❑SERIES RATING PERMITTED ■PAINTED STEEL ■NAMEPLATE O ■GROUND BUS REQUIRED ❑ -PANELS IN PARALLEL ❑THROUGH FEED LUGS REQUIRED PRIMARY OVERCURRENT &41N B4W0/NC AWZ-R (WRE, Res, FTC.) RE' ,SPEC _2'CA6V 250-79 -- / SECONDARY OVERCURRENT PHASE A PHASE B PHASE C GROUNDED CIRCUIT CONDUCTOR `1----1-1- EQUIPMENT GROUNDING TYPICAL GROUND BUS I-� CONDUCTOR, SIZED IN SUPPLIED WITH EQUIPMENT TYPICAL EQUIP. BONDING ACCORDANCE W/ SECTION JUMPER RE: SECT 250-95 BASED ON THE EQUIPMENT GROUNDING 250-79. SECONDARY OVERCURRENT PROTECTIVE DEVICE. CONDUCTOR, SIZED IN OUNDING ELECTRODE ACCORDANCE W/ SECTION CONDUCTOR SIZED IN 250-95 BASED ON THE SECONDARY OVERCURRENT ACCORDANCE W/ SECT, 250-94 PROTECTIVE DEVICE. IF SUITABLE BASED UPON THE SECONDARY GROUNDING ELECTRODE IS NOT CONDUCTORS. AVAIL- ABLE NEAR TRANSFORMER SIZE THIS GROUNDING CONDUCTOR ® '�-GROUNOING ELECTRODE NEARBY, PER 250-94 BASED UPON THE PREFERABLY THE STRUCTURAL SECONDARY CONDUCTORS. METAL. RE: NEC 250-26(e) TRANSFORMER GROUNDING 2"-4#1/0+6G 2 Yt"-4#4/0+4G 3"-3#500ECM+3G +3G SETS 3"-4#350MCM+1G 2 -4#1 /0+6 TS M 2"-4#1/0+6G 4' S4#600MCM+3/OG I I I I I I WLIJJ LJU/JJ 2JIUIJ - 1 I I TOTAL CONNECTED VA 1394799139371013884E d.3o- - I'CI;.L L.: TOTAL CONNECTED AMPc 1a951-TIT TOTAL DEMAND VA -------"-------'- PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE 0120/208 30,4W ❑120/240 30,4W ■277/480 30,4W BUS AMPS 0100A ❑400A ❑20GA ❑600A 0225A ■2000A MAIN DEVICE ❑MAIN LUGS ONLY E2000A CIRCUIT BREAKER Q ® ❑-_A FUSED SWITCH ENCLOSURE ❑FLUSH ESURFACE ENEMA t ❑HINGED DOOR ❑KEYED LATCH []DOOR -IN -DOOR ❑STAMYESS STEEL ■PAINTED STEEL ■NAMEPLATE BRANCH POLES 012 036 ❑18 E42 024 ❑- BRANCH DEVICES ■CIRCUIT 1REAKERS ❑FUSES ❑_TO BE GFCI BREAKERS ❑TOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A 030,000A ■65,000A 014,000A ❑42,000A 0100,000A ❑22,000A 050,000A ❑�OOOA ❑SERIES RATING PERMITTED ■SERVICE ENTRANCE RATED NOTES Q DIGITAL TRIP LS1G Q DIGITAL TRIP LS1 03 SHUNT TRIP FROM REMOTE BREAK GLASS SWITCH NEUTRAL BUS ❑50% ❑200% ■100% ❑- X BUS MATERIAL ■COPPER ❑ALUMINUM ■GROUND BUS REQUIRED ❑--°PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED CONNECTED VOLTAMI :AiBp Cal 7800 F- - - - 7812 831 biOU 8880. P:ANELBOARD SCHED1T1.E'LDP-1' LOAD DESCRIPTION MARES AMPS BUS AMPSPO WE CONNECTED VOLTAMP! AWG � A B C - -1 - - - -LOAD DESCRIPTION - - - - - AWG AO 80 Co LZ69851- 28551j TOTAL CONNECTED VA IU1AL VA TOTAL CONNECTED AMPS TOTAL DEMAND VA 12398 PANELBOARD RATINGS VP - PANELBOARD FEATURES VOLTAGE E120/208 30,4W ❑120/240 30,4W 0277/480 30,4W BUS AMPS 0100A ❑400A 0200A ❑600A 0225A 01200A MAIN DEVICE []MAIN LUGS ONLY ■1000A CIRCUIT BREAKER ❑-_A FUSED SWITCH ENCLOSURE []FLUSH ESURFACE ENEMA 1 ❑HINGED DOOR ❑KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL ■PAINTED STEEL ENAMEPLATE BRANCH POLES ❑12 ❑36 018 042 E24 ❑- 132ANCH DEVICES EORCUIT BREAKERS []FUSES 0-TO BE GFCI BREAKERS ❑LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A 030,000A ❑65,000A E42,000A ❑t00,000A ❑22,OOOA 050,000A ❑_,000A ❑SERIES RATING PERMITTED ■SERVICE ENTRANCE RATED NOTES 0014,000A Q Q3 Q NEUTRAL BUS 050% 0100% ❑ ❑200%❑ALUMINUM BUS MATERIAL ■COPPER EGROUND BUS REQUIRED ❑- PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED N I I I I 1 1 I I I 1 1 1 1 1 11111 O L10 L7 L6 L4 LDP2 H7 H6 HS H4 HDP2 SOUTH FPUA PAD HAC MOUNTED TRANSFORMER v 1'- 150A 225A 150A 150A 200A 400A 600A 1200A • METER 400A N lyo TVSS TVSS TVSS TVSS TVSS TVSS TVSS TVSS ST 0 TVSS m ST T2 225kVA 1n O C W 1 V5S pC;;0 a. TVSS a o TWO 4"-4#600MCM+i/OG (EA) 3/0 -3/0 I 0 I I ✓ o " 1 1/2^ U z On STUB OUT FUTURE FPUA L " PRIMARY CONDUITS 6 SETS 4-4#600MCM (AL)(EA)� Q t.. A On O to U z ir w w z C0 z w J z U T3 45kVA J, 32 3901 5T. LUCIE 5LVD. 34 [� (�' j 37 %424 TVSS 70 0 FORT FIERCE, FLORIDA 0 + 1 ONNECTED VA 450352 449229 448707 TOTAL DEMAND VA 124017 124463 123691 VATOTAL CONNECTED AMPS 162fi 1622 1620 3TOTAL DEMAND AMPS 3 --------------�-_-- SVB-TOTAL �A ti\11lllill PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE BUS AMPS MAIN DEVICE ENCLOSURE BRANCH POLES BRANCH DEVICES - 0120/208 30,4W ❑100A 0400A ❑MAIN LUGS ONLY ❑FLUSH 012 036 ■CIRCUIT BREAKERS ❑FUSES 5; �` r 41 0120/240 30,4W ❑❑18 E42 ❑ `TO BE GFCI BREAKERS200A ❑BOOA E2000A CIRCUIT BREAKER (D ® SURFACE - ' 7,''j • * , '/ �' I 1•° ;t -- ■277/480 30.4W 0225A ■2000A ❑_A FUSED SWITCH ENEMA 1 024 ❑- ❑LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ❑SERVICE ENTRANCE RATED []HINGED DOOR NOTES ', STATE OF ,'iO ❑10,000A 030,000A 065,000A NEUTRAL BUS BUS MATERIAL ❑KEYED LATCH 01 DIGITAL TRIP LSIG OM \FL ORIDP-• PER ❑22000A ❑50,000A ❑100000A ■100% ❑ROOK ❑ALUMINUM ❑STNNLESS STEEL 30 AUNT TRIP FROM REMOTE BREAK GLASS SWITCH ////SSPONAI ���\\\\ ❑SERIES RATING PERMITTED EGROUNO BUS REQUIRED ■PAINTED STEEL ❑_.-PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED ■NAMEPLATE PANELBOARD SCHEDIT1,E1DP-2' CONNECTED VOLTAMPS WIRES *`BUS WIRES CONNECTED VCDLTAMPS I55Ue5: AO Bp _LC LOAD DESCRIPTION qWG AMPS X A 8 C AMPS LOAD DESCRIPTION qWG No • Date: D06cri tion' ZWb- WIAL VA TOTAL CONNECTED VA 1478E TOTAL CONNECTFn AMPCI 395 4 0 18085 - - -00 CO - - 1 52-, 3 r A, 7/12/19 BID 5ET -- 14573 - B. 7/18/19 f ERMIT 5ET 1 1 c• leoo C. 9/135!19 CONTRACTOR FEV1510N5 J000 10/02/19 V.E. FEV1510N 3 TOTAL DEMAND VA - ---- -- .-...- --....I— .,,., PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE BUS AMPS MAIN DEVICE ENCLOSURE BRANCH POLES BRANCH DEVICES E120/208 30,4W 0100A ❑400A ❑MAIN LUGS ONLY ❑FLUSH 012 ❑36 ECIRCUIT BREAKERS ❑FUSES 0120/240 30,4W ❑20DA ❑600A 0800A CIRCUIT BREAKER ■SURFACE ❑18 ❑42 ❑__TO BE GFCA BREAKERS ❑277/480 30,4W 0225A ■800A ❑_A FUSED SWITCH ENEMA 1 024 ❑- ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ■SERVICE ENTRANCE RATED ❑HINGED DOOR NOTES ❑10,000A ❑30,000A ❑65,000A NEUTRAL BUS BUS MATERIAL []KEYED LATCH Q 014,000A E42,000A 0100,000A 050% 020011■COPPER ❑DOOR -IN -DOOR Q ❑22,000A 050,000A ❑-,OOOA 0100% ❑_ ❑ALUMINUM ❑STNNLESS STEEL 3Q ❑SERIES RATING PERMITTED EGROUND BUS REQUIRED ■PAINTED STEEL ❑ PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED ■ NAMEPLATE OO - 2"-4#3/0+6G 2"-4#3/0+BG 20-4#1/0+6G Fr 2"-4#1 /O+6G r- 2'-4#1/0+6G L3 L H3 L9 L8 L5 L2 L1 LDP7 150A 600A 200A 200A 150A 150A 150A TVSS TVSS TVSS TVSS TVSS TVSS TVSS TV55 1000A 40-4#600MC.M+3G RISER DIAGPAM SOURCE: 480Y/277V, 31fI, 4W THREE 3"-4#400MCM+2/OG (EA) Ti = DRY TYPE TRANSFORMER 4-BOA TO 20BY/12OV, 300kVA T2 = DRY TYPE TRANSFORMER 480A TO 208Y/12OV, 225kVA T3 = DRY TYPE TRANSFORMER 480A TO 208Y/120V, 45kVA Ti 300kVA 3/0 NOTE: THIS BUILDING IS SERVED WITH TWO ELECTRICAL SERVICES AS PERMITTED BY NATIONAL ELECTRICAL CODE (NEC) NFPA-70-(2014) SECTION 230.2(c) TWO-2 )k"-3#250MCM+iG 2 Y2"-4#4/0+4G Fr 4"-4#600MCM+3G r- 4"-4#600MCM+3G H8 H2 H1 225A 400A 400A TVSS TVSS TVSS HOPE S1 sT 20001 TV 3/0 NORTH FPUA PAD MOUNTED TRANSFORMER [METER 0 6 SETS 4'-4#600MCM(AL)(EA)-1 L PRIMARY CONDUCTORS BY © (CONDUITS INSTALLED BY ELECTRICAL CONTRACTOR) TCA = ASTRONOMIC TIME CLOCK FOR OUTSIDE LIGHTING CONTROL LC = 10 POLE LIGHTING CONTACTOR MECHANICALLY HELD El BREAK GLASS TYPE SHUNT TRIP PUSH BUTTON STATION ST TO TRIP OPEN MAIN CIRCUIT BREAKER ON HDP1 & HDP2 WHEN OPERATED 1/2" n DENOTES TYPICAL GROUNDING ELECTRODE CONNECTIONS. COLD WATER PIPE, BUILDING STEEL AND 3 %4 x10' COPPER CLAD DRIVEN RODS DENOTES TRANSFORMER GROUNDING. SEE DETAIL 11{IS SHEET a A,rchi�-ect� DONADIO & Associates, Architects P.A. MNJ 171h Slrwl Naar Bcuc. h,1432VEA! '1 A772.794,_N29 I+un 772Sfi2.8fAA1 ,v,v,v.Jmmitio-umh,,xn LiZT,, G>. AAINMh.27. Conoultant: CARDInRL 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@ C E A e ng i n ee rs . c om CA LIC. 31555 G'rawkj Title: FANEL50ARD5, DETIAL5 & R15ER DIAGRAM Job No-vi REVIEWED FOR CODE COMPLIANCE e� `7. LUCIE C"� OUN ' BOCC Urn: Drawii.? File: N_ ho: XKEF Hilo: DL Froject `Jo: P.ot Fl.e: 2016-42 5hee, No.: tort. No. date 5i�neo: E _ 2q- - 2"-4#3/0+6G 2"-4#3/0+BG 20-4#1/0+6G Fr 2"-4#1 /O+6G r- 2'-4#1/0+6G L3 L H3 L9 L8 L5 L2 L1 LDP7 150A 600A 200A 200A 150A 150A 150A TVSS TVSS TVSS TVSS TVSS TVSS TVSS TV55 1000A 40-4#600MC.M+3G RISER DIAGPAM SOURCE: 480Y/277V, 31fI, 4W THREE 3"-4#400MCM+2/OG (EA) Ti = DRY TYPE TRANSFORMER 4-BOA TO 20BY/12OV, 300kVA T2 = DRY TYPE TRANSFORMER 480A TO 208Y/12OV, 225kVA T3 = DRY TYPE TRANSFORMER 480A TO 208Y/120V, 45kVA Ti 300kVA 3/0 NOTE: THIS BUILDING IS SERVED WITH TWO ELECTRICAL SERVICES AS PERMITTED BY NATIONAL ELECTRICAL CODE (NEC) NFPA-70-(2014) SECTION 230.2(c) TWO-2 )k"-3#250MCM+iG 2 Y2"-4#4/0+4G Fr 4"-4#600MCM+3G r- 4"-4#600MCM+3G H8 H2 H1 225A 400A 400A TVSS TVSS TVSS HOPE S1 sT 20001 TV 3/0 NORTH FPUA PAD MOUNTED TRANSFORMER [METER 0 6 SETS 4'-4#600MCM(AL)(EA)-1 L PRIMARY CONDUCTORS BY © (CONDUITS INSTALLED BY ELECTRICAL CONTRACTOR) TCA = ASTRONOMIC TIME CLOCK FOR OUTSIDE LIGHTING CONTROL LC = 10 POLE LIGHTING CONTACTOR MECHANICALLY HELD El BREAK GLASS TYPE SHUNT TRIP PUSH BUTTON STATION ST TO TRIP OPEN MAIN CIRCUIT BREAKER ON HDP1 & HDP2 WHEN OPERATED 1/2" n DENOTES TYPICAL GROUNDING ELECTRODE CONNECTIONS. COLD WATER PIPE, BUILDING STEEL AND 3 %4 x10' COPPER CLAD DRIVEN RODS DENOTES TRANSFORMER GROUNDING. SEE DETAIL 11{IS SHEET a A,rchi�-ect� DONADIO & Associates, Architects P.A. MNJ 171h Slrwl Naar Bcuc. h,1432VEA! '1 A772.794,_N29 I+un 772Sfi2.8fAA1 ,v,v,v.Jmmitio-umh,,xn LiZT,, G>. AAINMh.27. Conoultant: CARDInRL 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@ C E A e ng i n ee rs . c om CA LIC. 31555 G'rawkj Title: FANEL50ARD5, DETIAL5 & R15ER DIAGRAM Job No-vi REVIEWED FOR CODE COMPLIANCE e� `7. LUCIE C"� OUN ' BOCC Urn: Drawii.? File: N_ ho: XKEF Hilo: DL Froject `Jo: P.ot Fl.e: 2016-42 5hee, No.: tort. No. date 5i�neo: E _ 2q- u FOR 5901 ST. LUCIE BLVD., FONT FIEKCE., FLORIDA CONSTRUCTION MANAGER KICHAKI) K. PAV15 CON5TKUCTION COKE@ F. 0. Box 186 Fort Fierce, Florida 54954 TeI.: 772/461-8555 Fax.: 772/465-7665 CIVIL ENGINEER CULFEFFER & TEKFENING, INC. 2980 5. 25th Street Ft, Fierce, Florida 34951 Tel.: 772/464-5557 Fax.: 772/464-9497 LAN D5CAFE ARCHITECT DOGGS 100 Avenue A Suite 2E Ft. Fierce, Florida 54950 Tel.: 772/486-5228 OCTODER 14.9 2019 VE REV15ION5 5ET MUSIROMIUVO & Associates, Architects P.A. 60917th Street Vero Beach, FL 32960 Te1.772.794.2929 Fax.772.562.8600 www.donadio-arch.com License No. AA0002238 STRUCTURAL ENGINEER M L ENGINEEKING INC. 2050 37th Avenue Vero Beach, Florida 52960 Tel.: 772/569-1257 Fax.: 772/569-4041 MECHANICAL / ELECTRICAL / FLUMBING ENGINEER CAR INAL ENGINEEPING A55OCIATE59 INC. 575 NW Mercantile FL, #106 Fort St. Lucie, FL 34986 Tel.: 561/746-6345 Fax.: 561/746-5602 VENTILATION CONSULTANTS VENTILATION 5OLUTION5 104 Meco Lane Oak Rldae, TN. 57550 Tel.: 865/298-0194 Fax.: 865/298-0199 SCANNED St Lucie Countv w a - REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY ROCC Project No.: 2018-42 PROPOSED MANUFACTURING BLDG FOR PURSUIT BOATS FORT PIERCE, FLORIDA