Loading...
HomeMy WebLinkAboutPRODUCT SPECIFICATIONSSUANNEO BY 8t Lucie C®UI RSTC Enterprises Inc SGAW 2214 Heimstead Roaskude Eau Claire, WI 54703 715-830-9997 Outdoor Pass thru enclosure: Asphalt/Cedar Roof Systems For AC or DC current ETL Listed and labeled to UL standards Report # 3125796 CRT-001 b Revised March 2012 • UL50 Type 313, 11 Edition Electrical) equipment enclosures CSA C22.2 # 94-M91 special purpo; enclosures (2006) Basic specifications Material - 18 Gauge G 90 Steel Base/Cover Process- Seamless draw (stamped) Flashing- 16" x 15" Height - 2.625" Cavity- 8" x 9" x 2.5" (162 Cubic inches) Finish- Powder coat (1100 hours salt spray) Assembly: • Cavity Base and cover punched for matc • Base Flashing pre -punched for roof dec� • Cavity Base - (5) predetermined dimples for fittings or conduit Base plate: • 16 gauge galvanized steel • Fastened to base flashing with toggle fa., • Finish — Powder coat (1100 hours salt ' I • (5) Roof deck knockouts • Knockout sizes — (3).5", (1).75" and (1)�" • Rail - 7" slotted 35mm Ground — Installed with steel stud and star (5) Position for wire size 14 — 6 Strain Relief Clip — Aluminum riveted in Hardware pack: 7 - 1" Truss head screws 4 - .5" 8-32 thread cutting screws 4 - Bonded seal washers #10 2 —10-32 %" Steel studs 2 —10-32 3/8" steel star nuts 1 — Foam gasket seal 1 — Installation instructions ied assembly mounting system S(JLADECK Model - 0786-313 5 With 2 circuit AC pass thru kit Kit Part # 01612 *** Kit sold separately E-Mount I QMSE Elevated Water Seal Technology° 1.1 ­^`AIARDS ROOF RIDGE ` AVA PROPpEFARY AND CONFIDPNTWF THE INFORMATION CONTANBD IN THIS DRAWING IS THESOUI! ROPRTY OF QUICK MOUNT PV. ANY REPRODUCUON IN PART OR AS A WHOIE WRITTEN PPRM=ON OF QUICK MOUNT PVO PROHIUHM. COPYRIGHT@2016 QUICK MOUNT PV 6 ' 5 4 G COMPONENTS IT INCLUDED_ ITEM NO. DESCRIPTION QTY. FLASHING, ROUNDED CORNERS, 9" X 12" X 1 1 .040", 5052, MILL 2 QBLOCK, CLASSIC, A360 CAST AL, MILL 1 3 HANGER BOLT, PLAIN CENTER, 5/16"x 6", 1 18-8 SS WASHER, SEALING, 5/16" ID X 3/4" OD, 1 5 NUT, HEX, 5/16-18, UNC-2B, 18-8 SS 2 6 WASHER, FLAT, 19/64" ID x 7/8" OD x 1 /8" 1 EPDM 7 WASHER, FENDER, 5/16" ID X 1" OD, 18-8 SS 1 8 WASHER, SPLIT -LOCK, 5/16" ID, 18-8 SS 1 _ Quick Mount PV' TITLE: _ —� - ---_ - QMSE: QMPV E-MOUNT E IN MILL, AND - -- --- - -,--DRAWN- - -- --- K FINISHES. ,UNLESS OTHERWRESPECIFIED: SIZE I BY: RAD , REV DIMENSIONS ARE IN INCHES A ! TOLERANCES: 4 A 'DATE: 5/9/2017 FRACTIONAL! I/8 I TWO PLACE DECIMAL !.19----" -- -- --- ---- ME DO NOT SCALE DRAWING THREE PLACE DECIMAL 2.094 'SCALE: 1:3 'WEIGHT:0.9172 SHEET OF I 3 2 1 Lag pull-out (withdrawal) capacities (Ibs) in typical lumber: Lag Bolt Specifications Specific Gravity 5/16" shaft per 3" thread depth 5/16" shaft per 1" thread depth Douglas Fir, Larch .50 798 266 Douglas Fir, South 1.46 705 235 Engelmann Spruce, Lodgepole Pine (MSR'1650 f a higher) 1.46 705 235 Hem, Fir .43 636 212 Hem, Fir (North) .46 705 235 Southern Pine .55 921 307 Spruce, Pine, Fir .42 615 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) I .50 798 266 Sources: American Wood Council, NDS 2005,Table 11.2 A,11.3.2 A Notes: , 1)Thread must be embedded in a rafter or other structural roof member. 2) See NDS Table 11 _5.1 C for required edge distances. Quick Mount PV" RESPECT THE ROOF BI 7.2.3-26 1 May-2017 Rev 6 E-Mount Installation Instruc Installation Tools Required: tape measure, roofing bar, chalk drill with 7/32" long -style bit, drill or impact gun with 1/2" de Locate, choose, and mark centers of rafters to be Carefully lift com mounted. Select the courses of shingles where bar, just above pl mounts will be placed. as required. See next page. V Using drill with 7/32" bit, drill pilot hole into roof Clean off any and rafter, taking care to drill square to the roof. compatible V Do not use mount as a drill guide. Drill should be 'long style bit, aka aircraft extension bit'to drill a 3" deep hole into rafter. eons e, stud finder, caulking gun, sealant compatible with roofing materials, socket. roof shinglewith roofing Insert flashing between 1st and 2nd course. Slide of mount. Remove nails up so top edge of flashing is at least 3/4" higher Flashing Placement" on than the butt -edge of the 3rd course and lower flashing edge is above the butt -edge of 1 st course. Mark center for drilling. idust, and fill hole with sealant Slide flashing into position. Prepare hanger bolt roofing materials. with hex nut and sealing washer. Insert into hole and drive hanger bolt until QBIock stops rotating easily. Do NOT over torque. • A Insert EPDM rubber washer over hanger bolt into Using the rac kit hardware, secure the racking block. (L-foot) to. th mount using torque specs from racking manufacturer. If racking manufacturer does not specify torque setting, tighten to 13 ft: Ibs. BI 7.2.3-26 May-2017 Rev 6 Reference and Tips Proper Flashing Placement '�4,T 1 If 1 1" 1 i-r— 1 — — —$I ��®l Additional tips and information for instolling mounts: ■ See Quick Tips videos on nail removal, bolt prep, and more at: http://www.quickmountpv.com/support/yi ideos.html ■ It is not necessary or advisable to use nails or other fasteners to secure the perimeter of the flashing. ■ The E-Mount is made to work with standard and high -definition composition/asphalt and wood shingle roofs with 5" to 5-5/8" courses. If tIIhe exposed surface of the course exceeds this measure- ment you may need to use our Classic Sh4ke Mount instead. ■ Depending on the season and climate, size and location of seal tabs, and quality of the shingles, the seal tabs that adhere the shingle cou�jlses together may not effectively seal the shingles to the flashings. If this is the case, simply add several quarter -sized dabs of manufacturer accepted sealant or asphalt roofing cement, meeting ASTM D 4586 Type II, between the flashing and the shingle above. ■ Mounts should not be installed in areas of the roof susceptible to ice damming. Water ponding un- der the shingles can reach the bolt peneilration. ■ Take care not to damage the roofing material while working on the roof. Removing stone granules and deforming the shingles in any way clan shorten the lifespan of the roofing. The value of the solar array is directly affected by the condition of the roof it is attached to. BI 7.2.3-26 1 May-2017 Rev 6 LCI Of.11 014291 1. PRODUCT NAME: 33000 Professional Grade Polyurethane Sealant 2. MANUFACTURER: Geocel Products Group A Business Unit of The Sherwin-Williams Company ("Geocel Products Group") Cleveland, OH 44115 Phone: (800) 348-7615 Fax: (800) 348-7009 www.GeocelUSA.com 3. PRODUCT DESCRIPTION: 3300& Professional Grade Polyurethane Sealant is a single component, high performance polyurethane sealant that withstands extreme weather conditions and cures to a flexible weatherproof seal. Product Benefits: • Withstands extreme weather conditions • Meets ASTM C 920 • Moisture cure • Flexible • Minimal shrinkage • Non -sag formula • Primerless adhesion on most surfaces • Paintable, non -corrosive • Contains no TDI (toluene diisocyanate) Basic Uses: 3300 Sealant can be used in roofing applications such as concrete roofing tile, clay roofing tile, metal roofing, Kynar 5000 coated metal, and composition shingles. Other applications include building lath paper repair, gutters, HVAC, flashing, skylights, roofing seams, roofing projections, termination points, and vents. TA Grade: Gun grade consistency Primer: Not required on most surfaces Packaging: 10.1 fl. oz. cartridges Colors: White, gray, limestone, bronze, medium bronze, tan, aluminum gray, black, and redwood tan Application Standards: Meets ASTM C 920 Type S, Grade NS, Class 25, Use NT, A, M, G, and 0; Meets Federal Specification TT S-0230 C, Type II, Class A; Meets Canadian Specification CAN/CGSB-19.13-M87 Class 2 Non -sag, Class 25, Class M. Limitations: • Do not apply over damp or contaminated surfaces • Do not apply to absorptive surfaces such as marble, limestone, or granite without prior testing for discoloration or staining 4. INSTALLATION: ' Joint Design: The width of the joint f' should be a minimum of 4 times the s anticipated movement. In joints up to 1/2" wide, the depth of the sealant should be equal to the width, but not less than 1/4". In joints wider than ,. 1/2", the depth should be maintained at 5/8". Lap shear joints should have a p width of at least twice the anticipated movement. Adheres To: Masonry, ceramics, wood, steel, Kynar 5001", aluminum, asphalt shingles, building paper, BUR, concrete, fiberglass, and other common building substrates. FIGURE 1 rwurtr Proper Depth Control Joints without Bond Breaker The effects on the sealant with and without bond breakers are it Joints with Bond Breaker d In Figures Two and Three. Surface Preparation: Joints to receive sealant must be sound, smooth, uniform in dimensions, and free from defects and foreign material. They must be clean, dry, and free of frost and all contaminants, such as curing compounds, sealers (waterproofing), coatings, etc. Sealant THERE IS A DIFFERENCE z w _Y LYURET 4 PP1,3LICONE HANEI��I� Kynar 500' is a registered trademark of Aricema Inc. adhesion should be tested on each different substrate prior to caulking. To test adhesion, apply a sealant bead and allow to cure thoroughly. Then pull one end of the bead to test adhesive strength. Joint Backing: Joint depth should not exceed 5/8". An open cell backer rod should be used to control joint depth. In shallow joints, a bond breaker tape should be installed to prevent three-point contact. Elongation: 881 % Tack Free: 3 hours Cure: 1 day Service Temperature: -20' F to 1500 F (-29° C to 66' C) Application Temperature: -20° F to 150° F (-29° C to 66' C) Application and Tooling: Apply with conventional caulking equipment. Fill joints from the back to prevent voids and air pockets. If application temperature is below 40° F (5° C), precautions should be taken to ensure the substrates are completely dry and frost free. Immediately after application, tooling is recommended to ensure firm, full contact with the joint sides. Cleaning: Remove 3300 Sealant from gun and tools before it cures. This may be done by scraping and use of solvents such as Xylol. Follow manufacturer's instructions for safe use. Cured materials may be removed by cutting with sharp tools or sandpapering. Storage and Shelf Life: Unopened containers should be protected from heat, moisture, and direct sun. Do not open containers until all preparatory work has been completed. Material in unopened containers is usable for up to 1 year when stored at 75' F (25' C). Cautions: CONTAINS ALIPHATIC POLYISOCYANATE HEXAMETHYLENE DIISOCYANATE. AROMATIC POLYISOCYANATE POLYMETHYLENE POLYPHENYL ISOCYANATE. METHYLENEDIPHENYL DIISOCYANATE. CRYSTALLINE SILICA VAPOR HARMFUL. Gives off harmful vapor of solvents and isocyanates. DO NOT USE IF YOU HAVE CHRONIC (LONG-TERM) LUNG OR BREATHING PROBLEMS, OR IF YOU HAVE EVER HAD A REACTION TO ISOCYANATES. USE ONLY WITH ADEQUATE VENTILATION. A POSITIVE PRESSURE AIR SUPPLIED RESPIRATOR (NIOSH approved) SHOULD BE WORN TO PREVENT EXPOSURE. IF UNAVAILABLE, AN APPROPRIATE PROPERLY FITTED APPROVED NIOSH vAPUH/PARTICULATE RESPIRATOR MAY BE EFF�CTIVE. Follow directions for respirator use. Wear the respirator for the whole time until all vapors are gone. If you have ahy breathing problems during use, LEAVE THE AREA and get fresh air. If problems remain or happen later, IMMEDIATELY call a doctor - If not available get*ergency medical treatment. Have the label with you. Adequate veptilation required when sanding or abrading the dried film. If adequate ver, tilation cannot be provided wear an app�oved particulate respirator (NIOSH app ved). Follow respirator use. IH iIIA contact wit TERM OVE sanding of crystalline to cause lu long term E Warning- I chemicals California' defects or NOT TAKEE,,l THE REAL 5. AVAILAE Available hardware technical local Gec h 'his product contains <nown to the state of o cause cancer and birth ether reproductive harm. DO INTERNALLY. KEEP OUT OF H OF CHILDREN. ITY AND COST m various lumber yards, rres, home centers, material and industrial Cost and further :a are available from your Products Group ,e or from our office. 6. LIMITER WARRANTY: If when applied according to label directions this product fails to perform ip accordance with its published literature, upon satisfactory evidence of product failure, and as your sole remedy, we will either replace the product at no cost or refund the original purchase price for that portion of product that fails to perform in accordance with this limited warranty. Labor or costs associated with labor are not included. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING MERCHANTABILITY, WHICH ARE ALL DISCLAIMED AND/OR LIMITED IN DURATION TO THE EXTENT PERMITTED BY LAW. WE SHALL NOT BE LIABLE FOR INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING LOST PROFITS) FROM ANY CAUSE WHATSOEVER AND SUCH DAMAGES ARE EXPRESSLY EXCLUDED. Some states do not allow the exclusion or limitation of incidental or consequential damages or how long an implied warranty lasts, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 7. MAINTENANCE. If sealant is damaged and the bond is intact, cut out the damaged area and recaulk. No primer is required. If the bond has been affected, remove the sealant, clean and prepare the joint in accordance with the instructions under "Surface Preparation," and recaulk. 8. TECHNICAL SERVICES: Geocel Products Group representatives throughout the U.S. are available to provide technical assistance. Geocel Products Group's in-house technical staff and laboratory facilities are equipped to respond to specific requests for further information and/or applications testing. T)-IEORE 11CAL YIELD Per 10.111. oz. Cartridge Joint Size Linear Feet 1/4" x 114" 24.1 1/4" x 3/8" 16.0 1/4" x 1/2" 12.0 112" x 3/8" 8.4 1/2" x 1/2" 6.0 3/4" x 1/2" 4.0 For additional product information, refer to the product spec sheet located at www.GeocelUSA.cont. �' .e„ So Cleveland, OH 44115 (800). 46-7615 -Fax (8001348-7009 e• OMGeocelPraluc[sG7oup SellingfheStanciord° www.Geoce]USA.com Ali<isinmUntoflh"Slcenvin•4YiBiamcCom my 70330D 0414 OR: SOLAR 1 T RN D N ; TANDARD Y EM mour E------� I e PAGE -------------------------------------------------------------------------------------------------- ��ATI O------------------------------- TERMINALTOROUE, WEEBLUG Install Conductor and Single Use Only .,, torque to the following: 6-14 AWG: 5ft-lbs 7. .+t �. �` - .r '.: � .. -,._ f+ •lie —. _ t Y ONE LUG PER OF MODULES: WEEBLUG CONDUCTOR - UNIRAC P/N 008002S: OnLyone lug,-p of modules is u }- fSeeaPage ' oradditl -1 lu eyuired for _ ' _ �� Apply Anti Seize and insert a bolt in the aluminum rail and through the clearance �hole in the stainless steel flat washer. Place the stainless steel flat washer on the bolt, —e on joints. - - oriented so-the-dimp.les_will_contact the aluminum rail. Place the Lug portion on the bolt and stainless steel flat washer. Install stainless steel flat washer, lock vvas er and` _ nut.Tighten the nut until the dimples are completely embedded into the rail and lug. TORQUE VALUE 10 ft tbs. (See Note on PG. A) See product data sheet for more details, Model No. WEEB-LUG-6.7 GROUNDING LUG MOUNTING DETAILS: Details are provided for both the WEEB and Ilsco products. The WEEBLug has a grounding symbol Located on the lug assembly. The Ilsco lug has a green colored set screw for grounding indication purposes. Installation must be in accordance with NFPA NEC 70, however the electrical designer of record should refer to the latest revision of NEC for actual grounding conductor cable size. Required if not using approved integrated grounding microinveters 'CGROUId6I ,N C1UL'G BOLT S ZE &DRILL SIZE ' _ "MIX, y GROUND LUG BOLT SIZE DRILL SIZE WEEBLug 1/4" N/A- Place in Top SM Rail Slot ILSCO Lug #10-32 7/32" • Torque value depends on conductor size. • See product data sheet for torque value. Star Washer is Single Use ON TERMINALTOROUE, Install Conductor and torque to the following: 4-6 AWG: 35in-lbs 8 AWG: 25 in-lbs 10-14 AWG: 20 in-lbs ILSCO LAY -IN LUG CONDUCTOR - UNIRAC P/N 008009P: Alternate Grounding Lug - Drill, deburr hole and bolt thru both rail walls per table. TORQUE VALUE 5 ft lbs. (See Note on PG. A) See ILSCO product data sheet for more details, Model No. GBL-4DBT. NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION