HomeMy WebLinkAboutENERGY EFFICIENCY CODE' FORM R405-2017
FLORIDA ENERGY EFFICIEN
Florida Department of Business and Profess
01FOR BUILDING CONSTRUCTION
Regulation - Residential P orm
ED
Project Name: MW-277
Builder Name:
MAY 18
Street: 3218 BENT PINE DR
Permit Office:
2018
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number:
ST, LuGi� �p�rizy, �Grl Ilttln�
Owner:
Jurisdiction:
Design Location: FL, ST_LUCIE_CO INTL
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2381.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 2071.40 ft2
b. Frame - Wood, Adjacent
R=11.0 309.78 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (2284.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2284.00 ft2
6. Conditioned floor area above grade (ft2) 2284
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(380.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 792
a. U-Factor: Dbl, U=0.62 380.43 ft2
SHGC: SHGC=0.26
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
48.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2284.0 sgft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2284.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 73.80
Glass/Floor Area: 0.167
PASS
Total Baseline L ads: 74.97
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with a Flori a Energy
specifications covered by this
O��kIESrgT�
�y
Code.
calculation indicates compliance
the Florida Energy Code.
!„
with
+nn •. •.:.:_ , ;,,�„ O
PREPARED BY:
Before construction is completed
DATE: 04/17/1X
this building will be inspected for
compliance with Section 553.908
I
* "'
I hereby certify that this ilding,as designed, is in compliance
Florida Statutes.
5�
G'Op
with the Florida Energy Co
WEI
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires cert9fication by the air handler unit mar
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection
envelope leakage test report with envelope leakage no greater
that the air handler enclosure qualifies as
klist in accordance with R402.4.1.1 and this project requires an
5.00 ACH50 (R402.4.1.2).
4/17/2018 8:14 PM EnergyGauge® USA F Res 2 § echo R405.4. Complia (Of
tw
Page 1 of 5
FORM R405-2017
PROJECT
i
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-277
User
1
Single-family
New (From Plans)
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:
Cross Ventilation:
Whole House Fan:
3
2284
1
No
0
No
No
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
3218 BENT PINE DR
St. Lucie
FORT PIERCE,
FL, 34951
CLIMATE
/
V Design Location
TMY Site 9T.5
Design Temp
T % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI
39 90
70
75 299
58 Medium
BL09KS
Number
Name
Area Volume
1
Block1
2284 21241.2
SPAdES
Number
Name
Area Volume Kitchen
Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
2284 21241.2 Yes
4
3
1 Yes
Yes Yes
FLOORS
i
#
Floor Type
Space Perimeter
R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 209.9 ft
0
2284 ft2
----
0 0 1
ROOF
V #
Type
Roof Gable
Materials Area Area
Roof
Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg) .
1
Hip
Barrel tile 2554 ft2 0 ftz Medium
0.45
N 0.9
No 0 26.6
ATTIC
V #
Type
Ventilation Vent R
tio (1 in)
Area
RBS IRCC
1
Full attic
Vented 1�0
2284 ft2
N N
CEIIJING
#
Ceiling Type
Space R-Value
Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30
Batt
2284 ft2 0.1
Wood
4/17/2018 8:14 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017
WALLS
()rnt
Adjacent
To Wall
Typepace
S#
Cavity
Width Height
Sheathing Framing Solar
Below
1
N
Exterior
Concrete
Block - Ext Insul
Main
4
32
0 11
4
362.7 ft2
0
0
0.3
0
2
E
Exterior
Concrete
Block - Ext Insul
Main
4
55
0 9
4
513.3 ft2
0
0
0.3
0
3
S
Exterior
Concrete
Block - Ext Insul
Main
4
58
2 9
4
542.9 ft2
0
0
0.3
0
4
SW
Exterior
Concrete
Block - Ext Insul
Main
4
8
9 11
4
99.2 ft2
0
0
0.3
0
5
W
Exterior
Concrete
Block - Ext Insul
Main
4
55
9 9
.4
520.3 ft2
0
0
0.3
0
6
NW
Exterior
Concrete
Block - Ext Insul
Main
4
2
11 11
4
33.1 ft2
0
0
0.3
0
7
Garage
Frame - Wood
Main
11
27
4 11
4
309.8 ft2
0
0.25
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood Main
None
.39
3
8
24 ft2
WINDOWS
Orientation shown is the ente
,ed, Proposed orientation.
v
Wall
Overhang
#
Ornt ID
Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
n 1
Metal
Double (Clear)
Yes
0.62 026
N
30.0 ft2
0 ft 0 in
0 ft 0 in
None
None
2
n 1
Metal
Double (Clear)
Yes
0.62 026
N
6.0 ft2
0 ft 0 in
0 ft 0 in
None
None
3
n 1
Metal
Double (Clear)
Yes
0.62 026
N
8.0 ft2
0 ft 0 in
0 ft 0 in
None
None
4
n 1
Metal
Double (Clear)
Yes
0.62 026
N
21.7 ft2
0 ft 0 in
0 ft.0 in
None
None
5
e 2
Metal
Double (Clear)
Yes
0.62 026
N
20.7 ft2
0 ft 0 in
0 ft.0 in
None
None
6
e 2
Metal
Double (Clear)
Yes
0.62 026
N
43.3 ft2
0 ft 0 in
0 ft 0 in
None
None
7
e 2
Metal
Double (Clear)
Yes
0.62 026
N
4.5 ft2
0 ft 0 in
0 ft 0 in
None
None
8
s 3
Metal
Double (Clear)
Yes
0.62 026
N
42.9 ft2
0 ft 0 in
0 ft 0 in
None
None
9
s 3
Metal
Double (Clear)
Yes
0.62 026
N
96.0 ft2
0 ft 0 in
0 ft 0 in
None
None
10
s 3
Metal
Double (Clear)
Yes
0.62 026
N
26.0 ft2
0 ft 0 in
0 ft 0 in
None
None
11
s 3
Metal
Double (Clear)
Yes
0.62 026
N
6.5 ft2
0 ft 0 in
0 ft 0 in
None
None
12
sw 4
Metal
Double (Clear)
Yes
0.62 026
N
18.7 ft2
0 ft 0 in
0 ft 0 in
None
None
13
sw 4
Metal
Double (Clear)
Yes
0.62 026
N
18.5 ft2
0 ft 0 in
0 ft 0 in
None
None
14
w 5
Metal
Double (Clear)
Yes
0.62 026
N
20.7 ft2
0 It 0 in
0 ft 0 in
None
None
15
w 5
Metal
Double (Clear)
Yes
0.62 0
26
N
7.0 ft2
0 It 0 in
0 ft 0 in
None
None
16
NW 6
Metal
Double (Clear)
Yes
0.62 026
N
10.0 ft2
0 ft 0 in
0 ft 0 in
None
None
GARAGE
i
#
Floor Area
Ceiling Area
Exposed Wall
Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
686 ft2
686 ft2
64
9.3 ft
1
4117/2018 8:14 PM EnergyGauge® USA - Fla Res2017-Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
INFILTRATION
# Scope Method
SLA
CFM 50 EIA
EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000295
1770.1 971.18
182.75 .2216
5
HEATING
YSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1 34 kBtu/hr
1
sys#1
COOLING
SYSTEM
i
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 16 48 kBtu/hr 1440 cfm
0.7 1
sys#1
HOT WATER
SYSTEM
# System Type SubType
Location
EF
Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94
50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER
SYSTEM
FSEC
Cert # Company Name
System Model
Collector
# Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCtS
/ --- Supply ----
�/ # Location R-Value Area
---- Return ----
Location Area Leakage
Air CFM 25 CFM25
Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 792 ft2
Attic
612 ft2 Default
Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling Jan Feb I Mar
Venting H HJan Feb Pq Mar
Ceiling Fans:
Apr Ma X J
W Apr May JLn
n X Jul X Aug�xj Se
Jul Aug Sep �X�
Oct Nov
Oct Nov
Dec
Dec
4/17/2018 8:14 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
Thermostat Schedule:
Schedule Type
HERS 2006
Reference
1
2
3
4
IHours
51
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78I
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
0
4/17/2018 8:14 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
.FORM R405-2017
ENERGY PERFOR
DISPLA
NCE LEVEL (EPL)
CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
3218 BENT PINE DR, FORT PIERCE, FL, 34951
1. New construction or existing
New (From Plans)
2. Single family or multiple family
Single-family
3. Number of units, if multiple family
1
4. Number of Bedrooms
3
5. Is this a worst case?
No
6. Conditioned floor area (ft2)
2284
7. Windows** Description
Area
a. U-Factor: Dbl, U=0.62
380.43 ft2
SHGC: SHGC=0.26
b. U-Factor: N/A
ft2
SHGC:
c. U-Factor: N/A
ft2
SHGC:
d. U-Factor: N/A
ft2
SHGC:
Area Weighted Average Overhang Depth:
0.000 ft.
Area Weighted Average SHGC:
0.260
8. Floor Types
Insulation
Area
a. Slab -On -Grade Edge Insulation
R=0.0
2284.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
�. Wall Types
Insulation
Area
a. Concrete Block - Ext Insul, Exterior
R=4.0
2071.40 ft2
b. Frame - Wood, Adjacent
R=11.0
309.78 ft2
c. N/A
R=
ft2
d. N/A
R=
ft2
0. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
2284.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
1. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Main
6 792
Cooling systems kBtu/hr Efficiency
a. Central Unit 48.0 SEER:16.00
, Heating systems kBtu/hr Efficiency
a. Electric Strip Heat 34.0 COP:1.00
1' .Hot water systems
Cap: 50 gallons
a. Electric
EF: 0.94
b. Conservation features
None
1 . Credits Pstat
I certify that this home has complied with the Florida Energy Efficien I y Code for Building
Construction through the above enerIt
saving features which will b;installed (or exceeded)
in this home before final inspection,herwise, a new EPL Display Card will be completed
based on installed Code compliant feures.
Builder Signature:
Address of New Home:
Date: I L11 I
*Note: This is not a Building E rgy Rating. If your Index is b
mortgage (EEM) incentives if ou obtain a Florida EnergyGauc
techsupport@energygauge.com or see the EnergyGauge web
certified Raters. For information about the Florida Building Coi
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building
.y/FL Zip:
3 -ys/
)w 70, your home may qualify for energy efficient
Rating. Email EnergyGauge tech support at
to at energygauge.com for information and a list of
,'Energy Conservation, contact the Florida Building
Energy Conservation, if not DEFAULT.
4/17/2018 8:14 PM EnergyGauge® USA - FlaRes2017 - Sec(ion R405.4.1 Compliant Software Page 1 of 1
wrightsoft. Load Short Form
Entire House
For: MW 277
3218 BENT PINE DR, FORT PIE
Htg
Cig
Outside db (OF)
43
90 Me
Inside db (° F)
70
72 Co
Design TD (°F)
27
18 Fir
Daily range
-
L
Inside humidity (%)
30
50
Moisture difference (gr/Ib)
0
68
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
8.6
kW
29480
Btuh
17
OF
1550
cfm
0.050
cfm/Btuh
0
in H2O
Job:
Date: Apr 12, 2018
By:
FL 34951
Infiltration
quality
Simplified
Tight
0
COOLING EQUIPMENT
lake Carrier
rade 16 SEER PURON AC
:ond CA16NA048****A
;oil FV4CN13006
,HRI ref 4585139
fficiency 14.0 EER,
16 SEER
ensible cooling
32550
Btuh
atent cooling
13950
Btuh
otal cooling
46500
Btuh
ctual air flow
1550
cfm
it flow factor
0.048
cfm/Btuh
tatic pressure
0
in H2O
oad sensible heat ratio
0.71
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ftz) (Btuh) (Btuh) (cfm) (cfm)
MASTER SUITE 382
5902
5352
296
HER WIC 87
1261
769
63
HIS WIC 44
47
245
2
GREAT ROOM 446
4061
4532
204
DINING 159
255i
2267
128
FOYER 57
1238
984
62
NOOK 109
31251
3488
157
KIT 200
211
1744
11
BED 3 149
1626
2595
82
BED3WIC 33
1069
641
54
CABANA 76
2112
2472
106
BED 2 188
1876
2732
94
BATH 2 59
948
740
48
UTILITY 49
117
721
6
MECH 36
467
653
23
MASTER BATH 210
4292
2610
215
Calculations approved
by ACCA to meet
all requirements of Manual
J 8th Ed.
At + wrightsoft' Right-Sulte® Universal 2012 12.1.05 RSU02818
Zm— C:\Users\Jason\Documents\Wrightsoft HVAC\MW-277.rup Calc = MJ8 Front Door faces:; N
255
37
12
216
108
47
166
83
124
31
118
130
35
34
31
124
2018-Apr-14 21:04:57
Page 1
Entire House
2284
309I 7
32545
1550
1550
Other equip loads
0
0
Equip. @ 0.95 RSM
30918
Latent cooling
13152
TlITAI [- I
nnnA
I nn^fN
AAnn
I AGGl1
I AGGf
-- wrightsoft" Project Summary
Entire House
For: MW-277 1
3218 BENT PINE DR, FORT PIERCE, FL 34951
Notes:
Weather: Vero Beach, FL, US
Winter Design Conditions
Outside db 43 'F
Inside db 70 °F
Design TD 27 'F
Heating Summary
Structure 25252 Btuh
Ducts 5655 Btuh
Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 30907 Btuh
Method
Construction quality
Fireplaces
Infiltration
Simplified
Tight
0
Heating Cooling
Area (ft�
2284 2284
Volume (ft?)
23239 23239
Air changes/hour
0.11 0.06
Equiv. AVF (cfm)
43 23
Heating Equipment
Summary
Make
Trade
Model
AHRI ref
Job:
Date: Apr 12, 2018
By:
Summer Design Conditions
utside db
90
'F
side db
72
'F
esign TD
18
°F
aily range
L
elative humidity
50
%
oisture difference
68
gr/lb
Sensible Cooling Equipment Load Sizing
tructure
25554
Btuh
ucts
6991
Btuh
entral vent (0 cfm)
0
Btuh
lower
0
Btuh
e manufacturer's data
n
to/swing multiplier
0.95
uipment sensible load
30918
Btuh
Latent Cooling Equipment Load Sizing
ucture
10872
Btuh
cts
2280
Btuh
ntral vent (0 cfm)
0
Btuh
uipment latent load
13152
Btuh
uipment total load 44070 Btuh
q. total capacity at 0.70 SHR 3.7 ton
Cooling Equipment Summary
ke Carrier
ide 16 SEER PURON AC
nd CA16NA048****A
it FV4CNB006
RI ref 4585139
Efficiency
100 EFF
Efficiency 14.0 EER, 16 SEER
Heating input
8.6 kW
Sensible cooling
32550
Btuh
Heating output
29480 Btuh
Latent cooling
13950
Btuh
Temperature rise
17 °F
Total cooling
46500
Btuh
Actual air flow
1550 cfm
Actual air flow
1550
cfm
Air flow factor
0.050 cfm/Btuh
Air flow factor
0.048
cfm/Btuh
Static pressure
0 in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.71
Calculations approved by ACCA to meet
all requirements of Manual J 8th Ed.
.ti + wrightsof't' Right-Suite(B) Universal 2012 12.1.05 RSU02818
,AiFM—
I
2018-Apr-1421:04:57
Page 1
C:\UsersWason\Documents\Wrightsoft
HVACUNW-277.rup Calc = MJB Front Door faces:
N
NOTE:
ALL RETURNS SHALL HAVE DIRECT DUCTING
TO RETURN AIR PLENUM BOX.
3215 BENT PINE
FORT PIERCE, FL