Loading...
HomeMy WebLinkAboutBUILDING PLANPROJECT LOG ISSUED FOR PRECON 03-23-18 ISSUED FOR PERMIT 04-24-18 GENERAL NOTES 1. THIS PLANS WERE PREPARED USING THE 2017 FLORIDA BUILDING CODE 61H EDITION 2. TYPE OF CONSTRUCTION: CLASS V, UNPROTECTED, GROUP R3 OCCUPANCY PER FLORIDA BUILDING CODE. 3. CONSTRUCTION SHALL FOLLOW THE FLORIDA BUILDING CODE AS ADAPTED BY THE COUNTY AND ALL APPUCABLE AMENDMENTS. 4. THESE PLANS, AS DRAWN AND NOTED, COMPLY WITH THE BUILDING ENVELOPE ENERGY REQUIREMENTS OF THE F.B.C. CHAPTER 13 ENERGY EFFICIENCY. 5. ALL WINDOWS AND DOORS SHALL BE CAULKED AND WEATHER STRIPPED. WINDOW UNITS SHALL DISPLAY LABELS SHOWING COMPLIANCE WITH THE F.B.C. CHAPTER 13 ENERGY EFFICIENCY SECTION. 6. REGISTERED BAITING SYSTEM FOR TERMITE TREATMENT TO BE INSTALLED AND MONITERED THIRD PARTY PRIOR TO FINAL BUILDING APPROVAL PER F.B.C. 2014 ABBREVIATIONS ABV ABOVE EXT. EXTERIOR AFF ABOVE FINISHED FLOOR F.B.C. FLORIDA BUILDING CODE AMU AIR HANDLER UNIT F.R, FIRE RATED B.F. BI FOLD FIR FRENCH DOOR B.P. BI PASS FIN. FINISHED BILK. BLOCK FL FLOOR BLN. BELOW G.T. GIRDER TRUSS BRIG, BEARING GA, GAUGE BTM. BOTTOM GALV. GALVANIZED CLG. COILING GFI GROUND FAULT INTERRUPT CMU CONCRETE MASONRY UNITS GL. GLASS COL COLUMN ONE GYPSUM WALLBOARD CONC. CONCRETE GYP. BD. GYPSUM WALLBOARD CSMT CASEMENT HOT, HEIGHT DEL. DOUBLE HPS. HOOPS DIA. DIAMETER MR HOUR DISP. DISPOSAL HS HORIZONTAL SLIDING DP DESIGN PRESSURE HVHZ HIGH VELOCITY HURRICANE ZONE DR. DOOR INS, INSULATION DW DISH WASHER INT, INTERIOR E.E. EACH END I.G. LONG ELEC. ELECTRICAL LIN, LINEN ELEV. ELEVATION LT. LIGHT E.S. EACH SIDE L.T. LAUNDRY TUB THESE PLANS WERE PREPARED USING THE 2017 FLORIDA BUILDING CODE 6th EDITION M.C. MEDICINE CABINET SMS SHEET METAL SCREWS M.R.H. MEAN ROOF HEIGHT ST. STIRRUPS M.T. METAL THRESHOLD STL STEEL MAX. MAXIMUM SW SWITCH MFR. MANUFACTURER TEMP. TEMPERED MICRO. MICROWAVE T.B. THROUGH BOLT MIN. MINIMUM T.O. THROUGH OUT M.O. MASONRY OPENING T.O,B.B. TOP OF MASONRY BOND BEAM MONO. MONOLITHIC T.O.PL TOP OF WOOD PLATE MTL. METAL T.O.TB. TOP OF TIE BEAM O.H.D. OVER HEAD DOOR TYR. TYPICAL O/C ON CENTER U.N.O. UNLESS NOTED OTHERWISE P.L.F. POUNDS PER LINEAR FOOT UL UNDERWRITERS LABORATORIES P.S.F. POUNDS PER SQUARE FOOT V.I.F. VERIFY IN FIELD P.S.I. POUNDS PER SQUARE INCH W.A. WEDGE ANCHORS P.T. PRESSURE TREATED W/ WTH PARTN. PARTITION WC WATER CLOSET PKT. POCKET WD. WOOD PLYWD. PLYWOOD R.O. ROUGH OPENING S.C. SOUD CORE S.G.D. SUDING GLASS DOOR SF SQUARE FOOT SH SINGLE HUNG ST LUCIE COUNTY PRODUCT APPROVAL OPENING SCHEDULE: OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS & SKYLIGHTS OPEN ID PRODUCT MODEL # MANUF. GLASS ATTACH. METHOD TYPE, SIZE, SPACING BUILDING DESIGN PRODUCT DESIGN DESCRIPTION AND EMBED. *FILL ALL MANUF. HOLES PRESSURE PRESSURE A FL-9174.10 R11 9100 OHO 16080 WAYNE DALTON N/A W/ 1-1/4" WASHER & 2-3/4- MIN. EMBED. D.P= +28.5 PSF D.P.= +39.2 PSF -43.7 PSF 2-3 4' MIN. EDGE DISTANCE. 6• FROM END PSF B FL 17499.4 (2) SH 25 MI WINDOWS & DRS NON IMPACT 3/16- TAPOONS W/ 1-1/4' MIN EMBED D.P= +29.9 PSF 55.0 PSF -55.0 PSF FL 15349.1 W/ F.O, ABV. 0 10. O/C MAX. SPACING & 0 FROM EDGE -32.7 PSF +60.0 PSF -60.0 PSF C FL 17499.4 SH 15 MI WINDOWS & DRS NON IMPACT 3/16- TAPOONS W/ 1-1/4' MIN EMBED D.P = +33.5 PSF +55.0 PSF -55.0 PSF FL 15349.1 W/ F.G. ABV. 010' O/C MAX SPACING & 2" FROM EDGE -36.3 PSF +60.0 PSF -60.0 PSF D FL-7630.2 3080 OR W/ THERMA TRU IMPACT 1/4' TAPCONS W/ 1-1/4' MIN. EMBED CORNERS 0 D.P= +31.9 PSF +50.0 PSF -50.0 PSF SIDEUTE 6" & 14" O/C MAX. SPACING. -34.8 PSF E FL 15349.1 4624 ARCHED MI WINDOWS & DRS NON IMPACT 3/16" TAPCONS W/ 1-1/4- MIN EMBED D.P.= +33.5 PSF +60.0 PSF -60.0 PSF TRANSOM EQUAL SPACING & 3' FROM EDGE -36.3 PSF F LL 17499•4 SH 35 MI WINDOWS & DRS NON IMPACT 3/16' TAPCONS W/ 1-1/4" MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 0 IC` O/C MAX. SPACING & 2' FROM EDGE -34.8 PSF G FL 15349.1 51020 TRANSOM MI WINDOWS & DRS NON IMPACT 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P= +33.5 PSF +60.0 PSF -60.0 PSF EWAL SPACING & 3' FROM EDGE -44.8 PSF H FL 17499.4 SH H33 MI WINDOWS & ORS NON IMPACT 3/16- TAPCONS W/ 1-1/4" MIN EMBED D.P= +33.5 PSF +55.0 PSF -55.0 PSF 010. O/C MAX. SPACING & 2" FROM EDGE -36.3 PSF I FL 17499•4 (2) SH 35 MI WINDOWS & DRS NON IMPACT 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P= +29.9 PSF +55.0 PSF -55.0 PSF 0 10- O/C MAX SPACING & 2' FROM EDGE -36.3 PSF J FL-7630.1 2880 SGL LITE DR THERMA TRU IMPACT 1/4" TAPODNS W/ 1-1/4' MIN. EMBED CORNERS O D.P= +31.9 PSF +50.0 PSF -50.0 PS 6- & 14- O/C MAX. SPACING. -41.7 PSF K FL 22401.1 12080 SGD MI WINDOWS & DRS NON IMPACT 3/16' TAPCONS W/ 1-1/4" MIN EMBED D.P= +28.5 PSF +55.0 PSF -55.0 PSF O 12' O/C MAX. SPACING -31.3 PSF L FL 15349.1 - 12014 TRANSOM MI WINDOWS & DRS NON IMPACT 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P.= +31.9 PSF +60.0 PSF -60.0 PSF EWAL SPACING & 3' FROM EDGE -34.8 PSF M FL-7630.1 2680 SOL LITE DR THERMA TRU IMPACT 1/4" TAPCONS W/ 1-1/4' MIN. EMBED CORNERS 0 D.P= +31.9 PSF +50.0 PSF -50.0 PSF 6- & 14. 0/0 MAX SPACING. -34.8 PSF N FL 17499•4 SH 26 MI WINDOWS & DRS NON IMPACT 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 010' O/C MAX. SPACING & 2- FROM EDGE -34.8 PSF 0 FL 15349.1 3214 TRANSOM MI WINDOWS & DRS NON IMPACT 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P= +33.5 PSF +60.0 PSF -60.0 PSF EQUAL SPACING & 3' FROM EDGE -36.3 PSF P FL 17499•4 SH 36 MI WINDOWS & DRS NON' IMPACT 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 0 100 O/C MAX SPACING & 2' FROM EDGE -34.8 PSF Q FL 15349.1 4614 TRANSOM MI WINDOWS & DRS NON IMPACT 3/16- TAPCONS W/ 1-1/4" MIN EMBED D.P= +33.5 PSF +60.0 PSF -60.0 PSF EQUAL SPACING & 3' FROM EDGE -36.3 PSF R FL-7630.1 2880 SOL LITE DR THERMA TRU IMPACT 1/4' TAPCONS W/ 1-1/4' MIN. EMBED CORNERS 0 D.P= +31.9 PSF +50.0 PSF -50.0 PSIF 6' & 14' O/C MAX SPACING. -41.7 PSF S LL 17499•4 SH H33 MI WINDOWS & DRS NON IMPACT 3/1V TAPCONS W/ 1-1/4' MIN EMBED D.P= +33.5 PSF +55.0 PSF -55.0 PSF 0 10. O/C MAX. SPACING & 2- FROM EDGE -36.3 PSF T FL 17499.4 SH 35 MI WINDOWS & DRS NON IMPACT 3/16- TAPCONS W/ 1-1/4' MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 0 10' O/C MAX. SPACING & 2' FROM EDGE -34.8 PSF U FL 17499.4 SH 35 MI WINDOWS & DRS NON IMPACT - 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 0 10" O/C MAX. SPACING & 2' FROM EDGE -34.8 PSF V FL 17499.4 SH 23 MI WINDOWS & DRS NON IMPACT 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P= +33.5 PSF +55.0 PSF -55.0 PSF 0IV O/C MAX. SPACING & 2' FROM EDGE -36.3 PSF W FL-7630.1 2868 DR THERMA TRU IMPACT 1/4' TAPCONS W/ 1-1/4" MIN. EMBED CORNERS 0 D.P.= +31.9 PSF +50.0 PER -50.0 PSF 8' & 14' 0/C MAX. SPACING. -34.8 PSF PRODUCT MODEL # MANUF. ATTACHMENT METHOD BUILDING DESIGN PRODUCT DESIGN TYPE, SIZE, SPACING, EMBED., STIFFENERS, ETC PRESSURE PRESSURE MULLIONS MAX 104-1/4" HORIZ. MI WINDOWS & DOORS 1/4' TAPOONS W/ 1-1/4- MIN EMBED (4) FASTENERS PER CLIP TOP & BTM. 37.7 PER 54.0 PSF -54.0 PSF FL 15353.4 3" VERL ROOFING NOA NO. 16-0314-.08 CAPISTRANO CONCRETE TILE EAGLE ROOFING (2) 10d RING SHANK NAILS -83.4 psf -172 psf, PRODUCTS ROOFING UNDERLAYMENT NOA N0. 17-0614-.22 POLYGLASS USA MEMBRANE: POLYSTICK TU MAX SELF ADHERED 1 OR MORE PLIES NAILS AND TIN CAPS 12" GRID, 6' O.C. AT A MIN. 4' N/A N/A SIBS UNDERLAYMENT INC. HEAD LAP SIDING STUCCO N/A N/A N/A N/A SOFFIT N/A 2 RING SHANK ATTACHED TO UNDERSIDE OF TRUSS STUCCO SPACED 0 EVERY HI RIB (V O/C) W/ 1-3/4- EMBED. N/A N/A PER NAIL HURRICANE PANELS FL 16293.1 HURRICANE STORM 1/4' -20 x 3/4' S.S. 120" MAX. SPAN GALV STEEL PANEL PANEL KNURLED STUDS 12-1/2" O.C. TOP AND BTM 37.7 PSF +49.0 PSF -56.0 PS MANUFACTURING, NC f MASONRY NOTES 1. CONCRETE UNITS TO BE ASTM C 90-90. ASTM GRADES NI OR NIT. PROVIDE PRECAST PLAN NOTES FRAMING NOTES ELECTRICAL NOTES UNTELS AS NECESSARY. (4m = 1500 PSI) 1. PROVIDE 1x2 P.T. FIRESTOP HORIZONTAL 0 CEILING & WALL INTERSECTIONS OR 8'-0" O/C 1. THE TRUSS LAYOUT SHOWN ON THIS SHEET IS SCHEMATIC IN NATURE. HOWEVER, THE 1. CONTRACTOR SHALL VERIFY WITH ELECTRIC PROVIDER THE LOCATION OF SERVICE AND VERT. MAX. AND ALL OTHER LOCATIONS PER F.B.C. SECTION 718 SUPPORTING SUPERSTRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THAT THE SHALL LOCATED METER & PANELS AS REQUIRED. 2. MORTAR TYPE M PER ASTM C 270-92. FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT, 2. ALL GLAZING WITHIN 24' AND PARALLEL TO A DOOR SHALL BE TEMPERED. 2. ALL WIRE SHALL BE THHN COPPER. UNLESS NOTED OTHERWISE. 3. CELLS, UNTELS AND BOND BEAMS WHERE SPECIFIED SHALL BE FILLED W/ 3000 PSI PEA ALL WINDOWS OR GLASS ENCLOSURES AT OR WITHIN 36" OF TUBS AND SHOWERS WITH SILLS 2• THIS FRAMING SCHEME (DIRECTION OF TRUSSES, MAJOR G.T. BEARING POINTS, ETC.) CAN GRAVEL CONCRETE. LESS THAN 60" ABOVE FLOOR SHALL BE TEMPERED. ALL GLASS IN SIDELIGHTS, SUDING GLASS BE MODIFIED ONLY AFTER OBTAINING PERMISSION FROM THE PRIME PROFESSIONAL OF 3. WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS SHALL BE 4. REINFORCING: DOORS AND FRENCH DOORS SHALL BE TEMPERED. RECORD WHO MUST REVIEW PROPOSED CHANGES AND AUTHORIZE STRUCTURAL REVISIONS COPPER OF EQUAL AAPACITY• ACCORDINGLY. VERTICAL• 3. EGRESS WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS. 4. ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED CABLE. EGRESS WINDOWS SHALL HAVE A MINIMAL NET OPENING OF 24" HIGH, 20" WIDE, AND MIN. NET 3. FINAL SIGNED AND SEALED ENGINEERED TRUSS DESIGN MUST BE SUBMITTED TO THIS AREA OF 5.7 S.F. FOR 2nd FLOOR WINDOWS AND 5.0 S.F. FOR tat FLOOR WINDOWS. THE OFFICE FOR REVIEW. TRUSS DESIGNERS MUST PROVIDE ALL TRUSS CONNECTIONS AS PART OF 5. COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO CONSTRUCTION. A. ASTM A815-94 PER REINFORCING SECTION (GRADE 60). BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44' ABOVE THE FLOOR. THE DESIGN. 6. VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER B. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE, IT SHALL NOT BE SLOPED MORE THAN ONE HORIZONTAL IN SIX VERTICAL ALIGNMENT, EVEN THOUGH IT IS IN AN 4. IN AREAS OTHER THAN HVHZ FIXED GLASS THICKNESS SHALL COMPLY WITH SECTION 2411 4• TRUSS MANUFACTURER SHALL SUBMIT THREE (3) COPIES OF SHOP DRAWINGS AND ENGINEERING CALCULATIONS SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER, OF SPECIFICATIONS. ADJACENT CELL TO THE VERTICAL WALL REINFORCING. OF F.B.C. AS THE MINIMUM THICKNESS ALLOWED. THEIR ROOF TRUSS DESIGN FOR REVIEW INCLUDING TWO (2) COPIES FOR ARCHITECTS REVIEW 7. PROVIDE DISCONNECT SWITCH OF SIZE AS REQUIRED BY LOAD AND UNITS. C. VERTICAL REINFORCING STEEL SHALL HAVE A MINIMUM CLEARANCE OF ONE-HALF INCH FROM 5. PROVIDE A MINIMUM OF 4" CLEAR ALL AROUND AIR HANDLER UNITS. PRIOR TO FABRICATION. REVIEW OF TRUSS SHOP DRAWINGS IS A COURTESY BY THE ARCHITECT AND IN NO WAY RELIEVES THE TRUSS MANUFACTURER OF HIS RESPONSIBILITY TO 8. PROVIDE NON -FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIP. AND AT THE MASONRY. PROVIDE A LAYOUT THAT FULLY INTEGRATES WITH THE ARCHITECTS SUPERSTRUCTURE. IF PUMPS NOT VISIBLE FROM CIRCUIT BREAKER PANEL AND AS PER MANUFACTURER. D. VERTICAL REINFORCING SHALL BE AS LOCATED ON THE PLAN AND AS INDICATED IN THE B. ALL DWELLING ROOMS MUST HAVE HVAC RETURNS. RETURNS MAY BE DUCTED, JUMPERS OR TRANSFER GRILLES. THERE IS ANY CONFLICT OR ADDITIONAL STRUCTURE NEEDED, THE TRUSS COMPANY SHALL NOTIFY THE ARCHITECT IN WRITING OF THE SPECIFIC AREAS OF CONCERN. RECOMMENDATIONS. COLUMN SCHEDULE. 9. PROVIDE OR BREAKERS FOR ALL BATHROOMS, GARAGE AND EXTERIOR OUTLETS AS 7. A/C UNITS MAY HAVE CONC. PAD OR OTHER APPROVED MATERIAL EXTENDING ABV. 5. TRUSSES TO BE DESIGNED TO CARRY LOADS OF ATTIC AHU AND MISC. EQUIPMENT. SHOWN ON PLANS. E. VERTICAL REINFORCING EACH SIDE OF ANY OPENING, IF REQUIRED, SHALL BE CONTINUOUS ADJOINING GRADE OR SHALL BE SUSPENDED A MIN. OF 6' ABV, ADJOINING GRADE. COORDINATE LOCATIONS WITH BUILDER PRIOR TO FABRICATION AND INDICATE ON TRUSS TO THE TIE BEAM. PRECAST UNTELS SHALL HAVE OPENINGS TO ALLOW REINFORCING BARS TO DRAWINGS. 10. ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED AND AS CONTINUE UNINTERRUPTED. BEAM SCHEDULE NOTES SELECTED BY BUILDER. HORIZONTAL- B. ALL INTERIOR LOAD BEARING PARTITIONS TO BE CONSTRUCTED 'NTH CLIPS, TOP AND BOTTOM EACH STUD, AS PER CODE. 11. PROVIDE PRE -WIRED TELEPHONE OUTLETS AS SHOWN ON PLAN. A. HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SCHEDULED IN THE BEAM SCHEDULE. 1. ALL COMPOSITE LINTEL (MARK "L") TOP BARS SHALL BE CONTINUOUS UNLESS OTHERWISE NOTED I12. 7. STRUCTURAL WOOD AND TIMBER FRAMING SHALL CONFORM TO THE "TIMBER CONSTRUCTION PROVIDE PRE- WIRED T.V. OUTLETS FOR CABLE AS SHOWN ON PLANS. 5. GENERAL: -BB-) MANUAL" AS,PUBLISHED BY THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION. 13. DEDICATED CIRCUITS SHALL HAVE NO MORE THEN 6 DUPLEX RECEPTACLES, 2. ALL BOND BEAMS MARK REINFORCING SHALL 8E CONTINUOUS THROUGH BOND REINF ( A. STRUCTURAL DESIGN IS IN ACCORDANCE NTH A.C.I. 5301 A.S.C.E. BEAMS ONLY. ALL SPUCES TO BE A MINIMUM OF 48 BAR DIAMETERS, B. ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED. 14. IN KITCHENS, DINING ROOMS AND BATHROOMS, RECEPTACLE OUTLETS FOR COUNTER 7-10/T.M.S. 402-05, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY ON BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES, 3. BOND BEAM SCHEDULE DEPTHS ARE MINIMUM AND MAY BE INCREASED 8" TO FIT BLOCK PROVIDE AN APPROVED MOISTURE VAPOR BARRIER BETWEEN THE CONCRETE OR OTHER CEMENTITOUS MATERIALS AND THE WOOD AS PER CODE. SPACES SHALL BE GFCI PROTECTED ACCORDING TO NEC 210-B (a)• B. CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I. 530.1-05/A.S.CE. 7-101602- WORK. 9. CARPENTER SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE BRACING AND BRIDGING USED 15. ALL CLOSET UGHTING SHELL COMPLY WITH NEC SEC. 410.8. 05, SPECIFICATIONS FOR MASONRY STRUCTURES AND THE COMMENTARY ON SPECIFICATIONS 4. REFER TO CONCRETE NOTES FOR INFORMATION ON CONCRETE AND STEEL SPECIFICATIONS. DURING ERECTION OF TRUSSES TO PREVENT COLLAPSE OR DAMAGE. 16. SMOKE DETECTORS SHALL BE CONNECTED TO KITCHEN OR BATH LIGHTING CIRCUITS FOR MASONRY STRUCTURES. 10. HEADERS FOR FRAMED OPENINGS GREATER THAN 6'-0' MUST BE ENGINEERED AND AHEAD OF SWITCH AND HAVE SELF CONTAINED BATTERY BACK-UP, DETECTORS MALL BE 6. VERTICAL CELLS FOR MASONRY TO BE GROUTED SHALL HAVE VERTICAL ALIGNMENT CONCRETE NOTES STAMPED BY THE TRUSS MANUFACTURER. (UNLESS NOTED OTHERWISE) TANDEM WIRED SO ALL DETECTORS SOUND SIMULTANEOUSLY. SUFFICIENT TO MAINTAIN A CLEAR, UNOBSTRUCTED CONT. CELL ' 17. PREWIRE FOR GARAGE DOOR OPENER SENSOR. 7. CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM Of GROUTED CELLS AT EACH 1. CONCRETE SHALL CONFORM TO ASTM C94-94 AND SHALL HAVE STRENGTH IN 28 DAYS AS 11. ALL HEADERS OVER DOORS AND WINDOWS TO BE (2) OR (3) 2X12'S UNLESS OTHERWISE NOTED, (FOR WOOD FRAME CONSTRUCTION DEPENDING ON ALL WALL THICKNESS). 18. ARC FAULT -INTERRUPTER PROTECTION PER NEC 210.12. REQUIRED FOR ALL 120-VOLT, LIFT OVER 4'-0" HIGH. CLEANOUTS SHALL BE SEALED AFTER CLEANING AND INSPECTION, AND BEFORE GROUTING. SPECIFIED IN THE FOUNDATION AND MASONRY NOTES (UNLESS NOTED OTHERWISE) ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318-11 AND ACI 301-05. ALL SINGLE, PHASE 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS DWELLING UNITS. CONCRETE MASONRY WORK SHALL BE IN ACCORDANCE WITH ACI 530-11. 12. DIMENSIONAL LUMBER SHALL BE SOUTHERN PINE. N0. 2 OR BETTER AND SHALL PROVIDE ALLOWABLE STRESS VALUES OF 1200 PSI IN BENDING FOR A SINGLE MEMBER USES. 90 PSI FOUNDATION NOTES ON IN HORIZONTAL SHEAR AND SHALL HAVE A MODULES ELASTICITY OF 1600 KSI OR BETTER, AS 19, CARBON MONOXIDE DETECTORS REQUIRED WITHIN 10' OF ANY SLEEPING ROOM. 2. MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE: SAGS VAPOR BARRIER - DETERMINED BY AN APPROVED LUMBER GRADING AGENCY. 3/4" BEAMS AND COLUMNS - 1 1/2' FORMED CONCRETE BELOW GRADE-2" UNFORMED 1. FLOOR SLAB TO BE 4" THICK POURED CONCRETE SLAB WITH FIBERMESH CONCRETE BELOW GRADE-3" 13. NON -BEARING INTERIOR PARTITIONS MAY BE CONSTRUCTED OF 20 0 24' O.C. PLUMBING NOTES ON 0.006 VISQUEEN (OR EQUAL) ON CLEAN WELL COMPACTED FILL 3. REINFORCING STEEL GRADE 60 (FY=60.000) ASTM A615-94. STUDS, WITH 1/2" GYPSUM DRYWALL EACH SIDE. ATTACH DRYWALL WITH 1- LONG BUGLE HEAD DRYWALL SCREWS AT 12" O/C MAX. 1. ALL PLUMBING FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 405, F.B.C. 2. ALL REINFORCING STEEL TO BE GRADE 60. 4. DETAIL OF CONCRETE REINFORCEMENT SHALL BE IN ACCORDANCE WITH 'THE MANUAL OF 14. METAL LATH OVER SHEATHING SHALL BE 3/8" V-GROVE OR DIMPLED. FASTEN TO 2. ALL PLUMBING FIXTURES SHALL MEET THE REQUIREMENTS OF TABLE 604.3, F.B.C. 3. COLUMN AND WALL CENTERLINES SHALL COINCIDE WITH FOOTING CENTERLINES UNLESS STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION' AS PUBLISHED BY THE CONCRETE REINFORCING STEEL INSTITUTE UNLESS NOTED OTHERWISE, SUBSTRATE AT 4° O/C AS FOLLOWS; CONCRETE: 3/4- LONG STUB NAILS W/ 3/8- HEAD. HORIZONTAL AND VERTICAL WOOD ;73. DISPOSITION OF RAIN WATER SHALL COMPLY WITH F.B.C. PLUMBING CODE CHAPTER 11. OTHERWISE NOTED. 4. FOOTING DESIGN BASED ON ASSUMED SOIL BEARING CAPACITY OF 2500 P.S.F., 5. ADEQUATE VERTICAL AND HORIZONTAL SHORING SHALL BE PROVIDED TO SAFELY SUPPORT ALL LOADS DURING CONSTRUCTION. FRAMING MEMBERS W/ NAILS OR STAPLES TO PROVIDE AT LEAST 1-3/4" PENETRATION INTO HORIZONTAL WOOD FRAMING MEMBERS, AND 3/4" PENETRATION INTO VERTICAL WOOD 4. ALL PLUMBING PENETRAIJONS MUST BE A MINIMUM 10'-0' FROM ROOF JACKS. FRAMING MEMBERS. ON VERTICAL WOOD FRAMING MEMBERS, COMMON NAILS SHALL BE 5. FILL PLACED WITHIN 5'-0" OF THE CONSTRUCTION PERIMETER SHALL CONSIST OF CLEAN 6. CONCRETE BEAM SIZES MAY INCREASED (8- MAX.) AS REQUIRED FOR ARCHITECTURAL BENT OVER TO ENGAGE AT LEAST THREE STRANDS OF LATH, OR BE BENT OVER A RIB 5. CONDENSATE DRAINS MUST BE A MINIMUM OF 12- OFF THE BUILDING. WELL GRADED SAND COMPACTED TO ACHIEVE A DETAILS OR FIT BLOCK COURSING, DROP BOTTOM OF TIE BEAM AS REQUIRED AT WINDOW AND WHEN RIB LATH IS INSTALLED. SHEATHING: 14 GAUGE STAPLES 1' LEG, 7/16" CROWN METAL MINIMUM OF 95% MODIFIED PROCTOR ASTM D 1557. DOOR BEAMS (28" MAX.) AND ADD 2-#5 BARS BOTTOM IF DROP EXCEEDS 8'. MTl_ FRAMING: SELF TAPING SCREWS /12 x 1/2" WASHER HEAD STAPLES SHALL NOT BE 6. INSTALL CHASE PIPE FOR HVAC. 6. ALL MONOLITHIC FOOTINGS HAVE BEEN CHECKED TO PREVENT THE USE OF TRANSFER USED FOR SOFFITS OR CEILINGS REINFORCEMENT AT PERIMETER. RATIONAL ANALYSIS SHALL BE SUBMITTED, BUT ONLY IF REQUESTED BY THE BUILDING OFFICIAL 7. DOWELS COLUMN AND WALL REINFORCING TO FOOLING WITH SAME SIZE AND NUMBER OF DOWELS AS VERTICAL BARS ABOVE. 15. PNEUMATIC FASTENERS SYSTEM TO BE HILTI-COIL NAIL PROGRAM. TYPE TO BE CRF 112G .I IYIECHANICAL NOTES 1-1/2' LONG AND .120" DIAMETER U.N.O. 7. CONCRETE FOR FOUNDATIONS AND FOOTINGS SHALL BE 2500 PSI MIN. S. REINFORCING STEEL SHALL BE LAPPED 48 BAR DIA. MIN. WHERE SPLICED AND SHALL BE WIRED TOGETHER. PROVIDE CORNER BARS SAME SIZE AND NUMBER AS HORIZ. BEAM 16. TRUSS MANUFACTURER SHALL DESIGN TRUSSES TO COMPLY WITH ALL SUPERIMPOSED 1. ALL HEATING, AIR CONDITIONING, REFRIGERATION AND VENTILATION EQUIPMENT SHALL B. DAMAGE PROBABIUTIES FROM TERMITE INFESTATION IS VERY HEAVY PER TABLE R301.2(1). REINFORCING AT EACH FACE. LAP 48 BAR DIA, MIN. WIND LOADS PER F.B.C. 2017 6TH EDITION & ASCE 7-10. CONFORM TO THE REQUIREMENTS SET FORTH IN THE "FLORIDA BUILDING CODE MECHANICAL" AND CHAPTER 28 OF THE FLORIDA PUILDING CODE. 9. PLACING DRAWINGS ON BAR LISTS SHALL CONFORM TO ACI'S "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE CONSTRUCTION AS PUBLISHED BY THE STEEL NOTES GARAGE NOTES CONCRETE REINFORCING STEEL INSTITUTE UNLESS NOTED OTHERWISE. i i 10. DAMAGE PROBABILITIES FROM WEATHERING IS NEGLIGIBLE PER FBC TABLE R301.2(1). 1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC "SPECIFICATION FOR THE DESIGN, 1: OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOUD WOOD PROPOSED SINGLE FAMILY RESIDENCE BY: "'ES "0' G` `0 AVALON LOT 277 MEADOWOOD COPYRIGHT 2018 TYPICAL "MI" WINDOWS N t0 c0 18d' 36" 52d" 25" SH 15 SH 25 SH 35 SH H35 ■ ■ is ■ • ■ M.O. 20 1/8' M.O. 38- M.O. 54 1/8' M.O. Z7 1/2' 1x, 2x, OR 5/4 BOARD 1x, 2x, OR 5/4 BOARD P.T. WOOD BUCK P.T. WOOD BUCK _ 38" 70" 38" - 1 SH 35 S '�, • °D ~ 4 l2l: TYP. BAY WINDOW FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" 2005 EDITION. MATERIALS DC IRS NOT LESS THAN i' (35 MM) THICK, SOLID OR HONEYCOMB CORE STEEL DOORS NOT SHALL CONFORM TO THE APPLICABLE ASTM SPECIFICATION AS FOLLOWS: SHAPES, PLATES A-36 LESS THAN V" (35 MM) THICK, OR 20-MINUTE FIRE -RATED DOORS. BOLTS - A 307-00 TUBULAR - A500-01a GRADE B (42 KSI) 2. DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR. CEILINGS SEPARATING THE 2. WELDED CONSTRUCTION SHALL CONFORM TO THE AMERICAN WELDING SOCIETY "STRUCTURAL DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MI WELDING CODE'. ELECTRODES FOR FIELD AND SHOP WELDS SHALL BE A.W.S. A5.1 E70XX. SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. 3. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LOAD SCHEDULE LESS THAN r (12.7 MM) GYPSUM BOARD APPUED TO THE GARAGE SIDE. LOCATION LIVE DEAD PA VN TOTAL GROUND FLOOR 40 50 10 100 SECOND FLOOR 40 15 10 65 ROOF 30 18 0 48 ATTIC 20 10 0 30 END:- UUTIMATE WIND SPEED = 160 m.p.h. BUILDING RISK CATEGORY = II BUILDING DESIGN AS ENCLOSED EXPOSURE = C ROOF DEAD LOAD FOR WIND DESIGN TAKEN AT 10 p.s.f. NQa THIS STRUCTURE IS DESIGNED IN ACCORDANCE WITH CHAPTER 16 OF THE FLORIDA BUILDING CODE AND ASCE 7-10. DESIGN PRESSURES FOR EXTERIOR DOORS AND WINDOWS ARE NOTED ON THE ELEVATIONS. WiNDOW AND DOUR MANUFACTURERS SHALL MULTIPLY THE GIVEN DESIGN PRESSURES BY THE APPROPRIATE FACTORS TO OBTAIN TEST PRESSURES. THERMA TRU EXTERIOR DOORS 2x P.T. WOOD BUCK SHOWN TYP. w g M.O. 35 1/4' W M.O. 37 1/4' W M.O. 41 1/4- W M.O. 55 1/2" W M.O. 78 1/2' W X 98 1/2" H X 98 1/2" H X 98 1/2' H X 98 1/2' H X 98 3/4- H EDGE OF SLAB EDGE OF SLAB EDGE OF SLAB EDGE OF SLAB I H EDGE OF SLAB 2680 EXT DR 2880 EXT DR 3080 EXT DR 3080 EXT DR W/ 14" SIDELITE PR 3080 DR (OUT SWING) (OUT SWING) (OUT SWING) (OUT SWING) (OUT SWING) DOOR INSTALLATION NOTE DOOR BUCKS USED MAY BE 2x6, 5/4" BOARD OR I& CONCRETE SCREWS USED TO SECURE THE DOOR FRAMES TO THE OPENINGS MAY BE ANGLED SUGHTLY WITHOUT APPRECIABLE LOSS IN RESISTANCE. ALL FASTENERS SHALL BE OF THE SIZE, LENGTH AND SPACING AS REQUIRED IN THE PRODUCT APPROVAL INSTALLATION PROCEDURES. SYMBOLS LEGEND DEFAIL SCALE DETAIL Dwc SCALE SECTION Dwc. SCALE -14 SECTION DWG. SCALE # INTERIOR ELEV, SCALE I BEAM LABEL /B /W\ \ REVISION N m � T / NORTH ARROW DRAWING INDEX C-1 COVER SHEET A-1 FOUNDATION PLAN A-2 FLOOR PLAN A-3 ELEVATIONS A-4 SECTIONS A-5 STRUCTURAL PLAN A-5 TRUSS PLAN E-1 ELECTRICAL PLAN M-1 MECHANICAL PLAN 1 4 DwG. 2 INTERIOR ELEVATION 3 0# COLUMN LABEL F# FOOTING LABEL _I11J Z --I GE POT SHELF HEIGHT AS NOTED DROPPED SOFFIT HEIGHT AS NOTED ARCHED OPENING SEE PLAN OR. ELEV. MASONRY CONSTRUCTION TYPICAL GROUT FILLED CELL SEE FOUNDATION PLAN NON -BEARING FRAME CONSTRUCTION BEARING FRAME CONSTRUCTION - - BREAK UNIE ELLV BEAM HEIGHT CHANGE U ]' ♦' 8 SCAMSDAIF: 1�, GRAPHIC SCALE 0'-0' FIN. FL SLAB FLOOR ELEVATION LLJ 9 v o w LL� J y M b a of LLj D LL LL W z J Z J 0 41 U j 0 n 0 O Q a m Z r 0 a Z O k E <L O ® Lo '•r Er U Jc U � O 10 C G c � r Z 0 � Ir �= Lo CV O N 1® s RECEIVt'u � MAY 10 2018 �.# O 0>M 1. : ­-r, F„y J LL_ Z o O O W n U fV i Q J W o � = V-0" U.N.O. COVER SHEET C-1 lKr ST. LUCI€ COUNTY BUILDINGDRASj7/ REVIEWED FOR COMPLIANCE REVIEWED DATE �e Lt✓MW 277 SITE OR 0 INSPEC IONS) WILLrB MADE L �, 8" W Q FIBERMESH OR FIBERMESH a, V' a WELDED WIRE MESH OR W.W.M. SEE FOUN. NOTES F0071NG REBAR 1-#5 CONT. SEE F0071NG SCHED. 3" MIN. COVER 10 o 34 THICKENED EDGE #1 Z e•' OTYP. EXTERIOR CONT. 1 MONOLITHIC FOOTING WOOD POST, FIBERMESH OR SEE FRAMING PLAN WELDED WIRE MESH PAD REBAR SEE FOOLING SCHED. EDGE BARS ALWAYS REMAIN. SPACE 07HERS EQUALLY. a 3 •'* 41'e SEE SCHEDULE OIN . MONOLITHIC PA CONC. COLUMN MATCHING DOWELS 48 BAR DIA. MIN. GRADE LL: WTD. HOOKS KS REBAR EQEQF0077NG SCHEWUDU LgE EDGE BARS ALWAYS REMAIN, SPACE OTHERS EQUALLY l � J ISOLATED PAD CONC. POURED FILLED - CELL W/ STL. PER PLAN DOWELL & EPDXY (1) #5- REBAR INTO SLAB 0 FILLED CELL LOCATION W/ 4" MIN. EMBED. INTO SLAB g" MATCHING DOWELS FOR �R COLUMNS BAR DIA. MIN. W/STD.D. HOOKS J p 0O g igONLY(2) MESH W.W.M. BAR SCHED.G SCHED. R BAR WHEN EQD. EXT. CONT. MONOLITHIC F-1 MISSED COLUMN STL. DETAIL TYP. HOLLOW MASONRY BLOCK RUNNING BOND PER PLAN CONC. SLAB & MONOLITHIC FOUNDATION PER PLAN FOOTING SCHEDULE MARK SIZE WxD REINFORCING DESCRIPTION DETAIL NO. F-1 20" x 18" X CONT W/2 15 CONT. EXTERIOR MONOLITHIC I F-2 20" x 18" X CONT. W/2 15 CONT. EXTER 0 RECI EOR SSMONOLI7HIC 38 F-3 2'-6" x 2'4" x 12" 1#/3 #5 E.W. B7M. PAD 0 INTERIOR WOOD POST 6 F-4 3'-0° x 3'-0" x 12" W/# 5'S 012" O.C. E.W. BTM. ISOLATED PAD 7 7E-1 10" x DROP x CONT. W/115 CONT. THICKENED EDGE AT DROP 34 COLUMN SCHEDULE MARK SIZE TYPE DESCRIP77ON CONC. BLK W/ 1 FULLY GROUTED CELL W/l-#5 VERT. 8x8 AT 6'-0° 0/C MAX. AND AT EVERY CORNER AND C-1 BLOCK BOTH SIDES OF ANY OPENING MORE THAN 6'-O' WIDE 8x16 CONC. BLOCK W/2 FULLY GROUTED CELLS W/1-#5 VERT. EACH CELL C-2 BLOCK AS LOCATED ON PLANS 8x12 C-3 BLOCK CONC BLOCK IN FULLY GROUTED CELL W/ 2-#5 VERT. IRREGULAR 45' M17ERED CONC. BLOCK IN FULLY C-4 BLOCK GROUTED CELLS W/ 2-#5 VERT. 4 X4" C-5 WOOD POST PROVIDE BASE AND CAP AS NOTED ON DETAILS 48 BAR DIA. SPLICE m .';r .n . ..t• m + ,. 8'x8" PRECAST LINTEL. SEE LINTEL SHOP DWGS. FILL COLUMNS AND LINTEL SOLID W/ GROUT 87x8" FILLED CELLS W/ 1 5 VERT. (TYP.) QDTYPICAL DETAIL LINTEL ON COLUMN 48 BAR DIA. SPLICE m SEE BEAM SCHEDULE FOR REINFORCEMENT 48 BAR DIA. S ICE FILL COLUMNS SOLID 8"x8" FILLED CELLS W/ PEA GRAVEL CONCRETE SEE PLAN AND COLUMN SCHEDULE FOR REINF. z TYPICAL DETAIL Al BEAM HEIGHT CHANGE u� v io a I M I y ao M C2 g o �o o= 1v C2 a n a 16,-0' 8'-0° I (2) SH 35 C2 HEAD 0 8'-0" loan F_ — — — — — F1 01 0 w I 8'-0" I I C2 HB C2 ®® ® o 3/4" RECESS 2880 o I SGL LITE i I < I 60'-0" 15 "1 10'-6" 17'-10" I 3'-71/2" 6'-101/2' 2'-6" 15-4" I 3,-0" C2 SH H33 HEAD 0 8'-0" i N o N �/4 3" RECESS M2V SH 36 W 188� F2 FG 18" HIGH SGL LITE 5-72'- " I FG ABV \6' T 6° SHOWER RECESS OC4 F� Fv C3 FORM SHOWER PAN f O 1 1/2" LARGER ON ALL - 2 F1 SIDES THAN ACTUAL _6 vJi / FINISHED DIMS. 7E-1 SHOWN HERE M I ° W yesR IC4 0 N 4 yG� L------ 12080 SGD SUPPLY U.G. COND. Hill F1 W/ 12016 FG. ABV. ( k PANEL) FOR POWER TO ISLAND HEAD 010'- " 5'-1 1/2 26'-2" -0 1/2" �- f ® I C5 OF7L--1I I L _J BRASS COVERED 2-8° 18'-6" FLOOR RECPT 0 26'-10" M � 0'0" FIN. FLOOR SLAB ED F1 C� F1 NOTE: ALL COLUMNS ARE Cl U.N.O. I I FORM SHOWER PAN M a0 1 1/2' LARGER ON ALL N o SIDES THAN ACTUAL a FINISHED DIMS. SHOWN HERE _ — — FE-1 —Q — — 5'-4° I I 3080 DR W/ �� oo WE — — — o �cv 4'-5" 6" SHOWER SFGETRANSOMRCHEDABV F1 L 1 3-$" 2'1 ° RECESS- iq C3 — — — F2 7 ® Io 4" o 6" 3'-3" c NOTE : FORM GARAGE SIDE DEMISING WALL 8 SMALLER THAN A RECESS FINISHED"DIMS SHOWN HERECTUAL F2 W N • — — — — — — I a ® ris ®® ® s ® ® ® ra (2) SF 25 ® 4' 0' 18'-8' r W ARCHED C2 i C2 ®® E D 0 7'_ 0 1 ®® al in ICI I�� F2 P O T S P OU — — F4 C2 ® 18" W X 5-V D RECESS \ \ FOOTER F OTER F4 I FOR PAVERS (FOOTING UNDER SLAB ® CO • COL. DEPTH MEASURED FROM CONDENSATE LINE \ EXT DR BOTTOM OF RECESS) W/ - 4 -6" 6" W X 3/4" D RECESS od od od Qi ad °? c6 od BEHIND (SLOPED) \ ai ad od ai cd ad cd ai ai cd\ 1\ (:s dodo dd ad cd d CS ` o v°o mµd-�715, I A oe} x o I 22'_0. 1'-4" 2'-10' 1, 2'-10" 1'-4" I N 4 SLOPE 2" ® CONIC. PAD 4'-4° 8'-4" 2'-4" 2'-0' 6'-6" 2'-0" 4'-7" 6'-7' , T EXTEND 5-1/2" DEEP RECESS 4":/ / I I PAST EDGE OF OPENING, TYP. FINISH ED E OF CONCRETE 22'-0° AT RECESS, TYP. C2 F2 F2 ® L — — — — F2 N ®® SH 35 o® P O T HEAD 7'-0" S P OU C2 DOTE F OTER C2 9'-4" T.O.B.B. ®CO . COL. 9'-4" TO.B.B. f0'-8" T.O.B.B. ]0'-8" T.O.B.B. 3'-8" 3'-10" 1'-4" 3'-10' 3'-8" 6'-7" 7'-6" 8'-4" 7'-6" 15-0" 10'-6" 11'-2" 23'-4" 0 ro PROJECT LOG ISSUED FOR PRECON 03-23-18 ISSUED FOR PERMIT 04-24-18 LJJ m � 0 rn a o u a J Z Lu _j ? Z J < z O m m w a 4 Q p " Z c 0 Qa LL a U 0 O O U n O U 1 O we G 1/4" = 1'-O" U.N.O. FOUNDATION PLAN A-1 '���!�MW - 277 CALCULATIONS TOTAL U/A 2284 S.F. COVERED ENTRY 73 S.F. COVERED LANAI 226 S.F. GARAGE 686 S.F. TOTAL AREA 3268 S.F. TOTAL AIR VOLUME CUBIC FT. = 21,241.2 ADDITIONAL NOTES: 1. STANDARD HOLLOW CORE RAISED PANEL DOORS. 2. TILE TO 7'-0" IN MASTER SHOWER AND 7'-0" IN OTHER LOCATIONS. 3. FIBERGLASS BOARD OR DUR-O-ROCK TO 7'-0" A.F.F. OR SOFFIT AROUND TUBS/SHOWERS AND TO 4'-0" A.F.F. 0 MARBLE TUBS 4. ROUNDED CORNERS AT ALL LOCATIONS EXCEPT CLOSETS, SLIDERS, WINDOWS, DOORS, VERTICAL EDGES OF CEILINGS OR AS NOTED ON PLANS. 5. KNOCKDOWN CEILING TEXTURE AND ORANGE PEEL WALL TEXTURE. 6. R-30 BLOWN -IN INSULATION AT ALL A/C AREAS GARAGE CEILING (4) 2x4 METAL STUD! FLOOR RO CEILING GARAGE FLOOR ELECT. PANEL / CHASE 0 io O"' ac 12" AC CONC. PAD DETAIL N.T.S. (2) #10 S.M.S. TOP & BOTTOM EACH STUD FINISHED CEILING - SEE TYP. WALL SECTION 2x6 BLOCKING CABINET LOCATIONS. FASTEN EA. END TO STUDS W/ (2) #10 S.M.S. EA. END 25 GAUGE CHANNEL SHAPED STUDS- (2X4 STUDS ® 16" 0/C) (2x6 STUDS 24" 0/C) W/l FULL LENGTH LAYER OF 1/2° TYPE GYPSUM WALLBOARD 0 APPLIED VERTICALLY & ATTACHED W/ 1" LONG BUGLE HEAD SCREWS TO EACH SIDE 0 12" 0/C CONT. 25 GAUGE METAL TRACKS TOP & BOTTOM CONC. FLOOR SLAB HILTI PINS .145" DIA x I' LG. ® 16" 0/C W/ 1" WASHERS TYPICAL INTERIOR PARTITION ALONG CABINETRY BACKING SCALE 3/4" = ID" WASHER DRY R 28-1/2" SPACE DRYER VENT DRYER VENT LOCATION FRONT VIEW R-30 BLOWN -IN INSULATION AT ALL A/C AREAS ALL INSULATION SHALL COMPLY WITH FBC R302.10 FLAME SPREAD COMPLIANCE 25. SMOKE DEVELOPED INDEX 50. ALL CEILING AND WALL FINISHES SUCH AS PAINT SHALL COMPLY WITH FBC R302.9.2 AND BE LESS THAN THE VALUE OF 200. 3/4" THK TEMP TOP OF KNEEWALL W/ PT 2X TOP PLATE & 1/2 W/ CLIPSPLYWD FRAMELESS GLAil& & 1/2" NON ASBESTOS FIBER CEMENT BACKER BOARD 1/2" WALL CAPKNEEWALL W/ NON ASBESTOS FIBER CEMENT BACKER BOARD MTL FRAMINGON SHOWER NB SIDE KNEEWALL W/ D TILE FINI H FINISH THIS SIDE a a U w ROMAN SHWR K PT 2X SILL PLATE LLLL, LLLLLL LLLLLL LLLLLLL TYP. KNEE WALL SECTION 1/2" = 1'-0" FINISHED CEILING 2x WD BLOCKING EACH SIDE OF M FOR MOUNTING 2x MTL. STUDS TYP. FINISHED FLOOR TYP. MEDICINE CABINET (2) 110 S.M.S. TOP & BOTTOM 0 EACH STUD FINISHED CEILING - SEE O TYP. WALL SECTION CONT. 25 GAUGE METAL TRACKS TOP & BOTTOM W/ (1) #10 SMS 0 24" 0 C 25 GAUGE CHANNEL SHAPED STUDS 24" O/C W/1 FULL LENGTH LAYER OF O 1/2" TYPE GYPSUM WALLBOARD APPLIED VERTICALLY & ATTACHED W/ 1" LONG BUGLE HEAD SCREWS TO EACH SIDE 0 12" O/C CONC. FLOOR SLAB HIL77 PINS .145" DIA x 1" LG. ® 16" 0/C W/ 1" WASHERS 1 INTERIOR PARTITION A-2 3/4" - l'-O" �o n O M m m of ro Ib Ia mod mro mro 00 00 00 ^ N N 60'-0" 16'-0" 15' " 10'-6" 8'-0. 8'-0. 3'-7 1/2' 6'-101/2" 2'_6" d2) SH 35 (E RESS) HB I — — — — — — O SH H33 -- — --- --- ® o o O R C J N AB Q SH 36 (TEMP) 2880 — — — — — — — — 2880 I BL P W/ 16" HIGH SGL LITE SGL UTE O FG ABV CABANA I ® COVERED N �ti6��`'J �� ® - 0 3.- . I I LANAI 1 `� ABV. 0 1 ll'-4" CLG. I MASTER I m (ABV MAIN SLAB) " BLW. N 28 O SUITE ® NOOK 9'-4"/10'-4" CLG. PAVERS 11'-4" CLG. I A� O m 12080 SGD (4 PANELS) N 02680 LID Z I ® BL .OW 16° HIGH FG TRANSOM ABV SGL LITE 10'-2" B" 3'-0" 10" I F2-O FLAT ARC13'-9 1 2 2'-10 1 2 �i SPRING 0 8'-0" 2'-0" / " / " KITCHEN CONVENIENCE PACKAGE a TOP ® 8'-8" i io 14'-8" 4 17'-4" 4" 5'-6" 2'-8° 5'-6"4. SOAP 3 DISPENSER FLAT ARCH GREAT ROOM Y o m 0 0 SPRIN ®-8" Z O k? n Y< 1l'-4" TO 12'-4" COFF. CLG. N O O c? ISLAND � °a rn i MICRO/ In DW KIT o WALL 2680 I � 3 ll'-4" CLG. v OVEN 5'-8" 3' 8" " 4" 1'-4- J. 1 � o HERS o I HIS REF_ 2xr a z LF f _j N I m 2680 w 2'-81/2° 4'-111/U I S-8" 2'-0" 2 I � " ------ -----gym L --- 2. 3, 2. ..-2" - 4' 2" - - FLAT ARCH ------- - o ¢ I — Oro 4 SPRING 0 9'-0" a N N TOP ® 10'-6" v i FLAT ARCH fl L SPRING ® B'-O" Tn ® R,_R„ 4" 6'-2" N FOYER m N 12'-4" CLG. z a c� iv I I 13 �LLap N M� �v1ASTER FULL LITE 3080 DR W/ SIDEL TE &ARCHED I Ito o * 0 I BATH FG TRANSOM ABV 4" CLG. ABV. E BLW. D MA ILU N SHWR — — — VANI I PAVERS ARCH 36" FF 8'-0" COVE ED q CSPRIN( ® ®® ® ENTRY18 � c s 5' 8" 811O O a, (2) CORNOR SHELVE o, ;0 1 14'-0" LG. A.F.F./ (ABV MAIN�SLAB) N OC ® ° ®® SH 35 ®K 00 (TEMP) OF 48"WIDE x 68" DEEP TUI DEC I I 4'-6. m@d rommm roro 05 (zd 05 ai ai m I Qi a5 d(zi odoo 0 1j j j A a A4 2'-0" 1'-4" 2'-10" 2'-10" l'-4" N 4'-4" 8'-4° 2'-4° 2'-0" 6'-6" 2'-0" 4'-7" of a 15'-0" L 10'-6" ZV H U UTIL. — r PT D 1, N N DINING 11-3 LOP�� l l'-4" CI-G. 17'-10" BEDROOM 3 9'-4" CLG. -0. 0 BEDROOM 2 o My O T-4" CLG. O 9,-8. BATH 2 11 6'-10' 6080 BP GARAGE SEPARATION REQUIREMENTS PER 302.6 4" -6 4" R-11 BATT INSULATION FOR DEMISING WALL PER ECALCS (2) SH 25 W/ 1/2 FG ABV. i 60'-0" I 6'-7" MECH E H ' 0" !20 22"x54 PULLDN STAIR MIN. SOLID CDR L W/SW. LT. J® R W/ RABBITTED ®AMB OVERSIZEDATHERSTRTPFIo _ ATTACH P.T. 2X8 I ABV. GARAGE DOOR PER MANUF. SPECS I 2 BAY GARAGE o z2'-o" N IQ I= o GARAGE SMOOTH COAT � 0 � STUCCO FINISH AT EXTERIOR o MASONRY WALLS. STUCCO TO z STOP 0 INTERIOR DRYWALL IJ I 22'-0" wool IARL -STM i �� ®® OSH 35 ®a O.B.B. O.B.B. l'-4" 2'-10" 2'-10" 1'-4" 7'-6" HOSE BIBB - CHASE 7'-6" O N a O T.O.B.B. TO.B.B. PROJECT LOG ISSUED FOR PRECON 03-23-18 ISSUED FOR PERMIT 04-24-18 W d = 0 m o W a w W z Z Z 0 W Z)' z _jO N z 0 M U J a n ` LL N o z = 0 Oa 0 O H J On LL a Z 0 O OU O W n Q U N � � J ' W 1 57 L) 1/4" = 1'-O" U.N.O. FLOOR PLAN A-2 z lMW - 277 u ® ow A QVWWPG1 a k2wwf•w+rtvMl -T vnylwrp oT N e ez 0i, /•r84 Clarke .k D'okorm8 i" o", ." or krllSt ( I6ar flo ue a31 r....i xlr 11 G5 PROJECT LOG ISSUED FOR PRECON 03-23-18 ISSUED FOR PERMIT 04-24-18 111111 1* Mid Wall (M Styr) Control Joint Designed to relieve stress and assist in controlling cracks in exterior Leah finish. Intersections of Ts available. / �f 167E-60UL 7I8"x112" 1 3-1/2"solltl flange, 1-3/4" perforated flange Mid Wall Control Joints — Designed to relieve stress and assist in controlling cracks in exterior wall finish_ Intersections of Ts available US Patent Number'i, 757450 Caulk all Intersections, butt joints, ends and oomel at time of Incfalladon. NorA illvil ar avkDM' WilMi�y �lNYrtf� 15 Product Submittal Street vinylcorp cam 8000 NW I&h Plecc P 305 4T 64rc Clarkwmsar Dsi t~stems kLC hen Hot'da 33166 F'0547.1108 Soffit dents (One Puce) Continuous one-piece Soffit Vent with reinforcing rib to key into stucco &amp; plaster. K s-s^-;`c:y lS'��• CS58-300V I 5/8, I 3" wide vent (one piece) 5" overall width, perforated flanges 1 15 3" Soffit Vents —Continuous one piece Sofn Vent with reinforcing rib to key into stucco &amp: plaster. Vent Clips are provided to connect Soffit Vent and to assist in alignment. vent areal 15 square Inches per Ilnaal ft Caulk all intersections, butt joints, ends and comers at time of installation. ATTIC VENT CALCULATION: (SQ IN) ROOF AREA CALCULATED 0 3268 (SO.FT.) x 144 = 470,592 SQ IN. / 150 ee 3,138 SQ. IN. REQUIRED NET VENT AREA 15 SQ IN. PER LINEAR FT. (257 LF) VENT = 3,855 SQ. IN. TOTAL NOTE: CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF VENTS "S" BARREL CONCRETE TILE 901 FELT SELF-ADHESIVE UNDERLAYMENT OVER 30j FELT TIN TAGGED TO EXT. GRADE PLYWO. SHEATHING (SEE DIAPHRAGM SCHEDULE FOR TYPE & NAILING PATTERN) PRE-ENG. WOOD ROOF TRUSSES l 0/C TYPICAL W/APPROVED GALV. TRUSS ANCHORS EA. END $ SEE PLAN/ ELEV. GALV ll DRIP ON iX2 P.T. 2x8 PAINTED TEXTURED —� SPRUCE FASCIA CEMENTITOUS FINISH ON METAL LATH ATTACHED W/ 3" CONTINUOUS VENTING ON ALL SIDES (TRUSS CO. TO PROVIDE FLAT SOFFIT) MEDIUM TEXTURE DECORATIVE CEMEN7iTOUS FINISH OVER 8' CONC. BLOCK NOT TO EXCEED 5/8" THICKNESS R 4.1 FI-FOIL BETWEEN STUDS 0'-0" FIN. FL. SLAB - u 12 6 1 INSULATION PER ENERGY CALC. RAT RUNS PER. TRUSS MANF. 5/8" DRYWALL OR i12" "TOUGHROCK" UEQUALD TO NDERSIDE)OFPPLIETRUSSES FIRE STOP CONT. 8"xi6" MASONRY BOND BEAM W/ 115 CONT TOP & BOT - FILL W/ CONC. CONT. METAL POUR STOP 1/2" DRYWALL iX2 P.T. FURRING ® 24" 0/C EXTERIOR BLOCK WALL ,TO BE WOOD BASE MONO. GONG, FOOTING SEE FOUNDATION PLAN FOR NOTES & DETAILS a . •°' III —III ;I ,• • .• I I I I I I I TYPICAL WALL SECTION SCALE 314' = i'D" OLMLNIIIUUS FINISH, TYP. —o4.a rar i F 1 al'- FOR WALLS `J BLW 34.8 PSFSF D.P.= +PSF FRONT ELEVATION - CLASSIC a = 6'-0' 12 6 O a = 6,-0" �] FIXED GLASS fV 5'-10" D.P.= +33.5 PSF D.P.= +33.5 PSF -36.3 PSF O o _44 8 PSF O I G 14'-0" T.O.B.B. 0'-0" FIN. FL. SLAB D.P.= +28.5 PSF -34.8 PSF O LEFT SIDE ELEVATION- CLASSIC D.P.= +31.9 PSF D.P.= +31.9 PSF D.P.= +31.9 PSF D.P.= +31.9 PSF D.P.= +28.5 PSF D.P.= +31.9 PSF D.P.= +29.9 PSF 0 -417 PSF -34.8 PSFO -34.8 PSFO -34.8 PSF O -31.3 PSF 0 -41.7 PSF O -36.3 PSF 0 REAR ELEVATION (AROUND CORNER) (AROUND CORNER) ^W r) m ad m W ad u J LJ iij a = � 1- fA a z W rn M � LL m m LL W Z Q Z J 0 Q U N do O a I m rn ba zi Z 0 0 a Q c cta 18 0 0 Ql N cn . 'i7 d c -a 0. C- C .� `o ,rn ti o 0 ev In c M N E a > CD w a' N O 19 V CL O N O O C a a� E E o a o _oCL V C O v n o co cuo F- E (� 0 C cu C p= w a) E Lon co TvS zLg a rG 14'-0" T.O.B.B. 12'-0" T.O.B.B. 11'-4" T.O.B.B. 9'-4" T.O.B.B.All -� 0'-04 FIN. FLOOR SLAB /-ki Z Q E 0 Lo O U m . cn 0 rA C — W U3 ^ V V 1'. _ (``� a 2 0 _I LL- M O 0 W N Q J f W --I = P-0" U.N.O. ELEVATIONS A-3 277 I✓ TYPICAL INSTALLATION WINDOW ASSEMBLY MARBLE SILLS CAULK ITENERS AS REQUIRED WINDOW MANUFACTURER *CONTRACTOR TO APPLY TO ALL SIDES OF MASONRY OPENING INCLUDING HEADER AND JAMBS PER FBC 2017 703.4 SHER-CRETE FLEXIBLE CONCRETE WATER PROOF - SMOOTH A5-200 SERIES SHERWIN WILLIAMS MANUFACTURER APPLY PRODUCT DIRECTLY TO CLEAN CONCRETE SUBSTRATE PER MANUF. SPECS <'e' Q, WIIVUVW IrvJIHLLX IIUIV 'MORTAR OR e. GROUT a. 1•<.' •, a „e' SET SILL IN FULL DRYWALL P,. "<' .� MORTAR BED AND HEAD JOINT STUCCO OR DECORATIVE 4 ; _ ,. �CEMENTITIOUS COATING 3/4" FURRING TO e MASONRY WALL 4 8" C.M.U. e .• e a CAST-CRETE PRECAST SILL DETAIL SHERWIN WILLIAMS CONCRETE WATER PROOFING APPLICATION CEMENTITOUS FINISH ATTACHED TO METAL LATH ATTACHED TO UNDERSIDE OF TRUSSES RAT RUNS PER TRUSS MANF. (MAX. 8' O.C) D.P.= +31.9 PSF -34.8 PSF O 6'-6" PROVIDE CEMENTITOUS FINISH PRIOR TO METER INSTALL 1�6 COUNTER BEYOND yy D.P.= +31.9 PSF -34.8 PSF O PRE ENGINEERED WD. TRUSSES @ 24" O/C TYPICAL R-30 INSULATION AT AIR CONDITIONED CEILING LOCATIONS 0 9L D.P.= +33.5 PSF -36.3 PSF O OPENING TO DINING. ROOM I LOW WALL FOYE N I m 0 a O I m 12 6 D.P.= +31.9 PSI O-34.8 PSF ENTRY D.P.= +33.5 PSF -36.3 PSF O -6" D.P.= +31.9 PSF -34.8 PSF O RIGHT SIDE ELEVATION - CLASSIC CEMENTITOUS FINISH ATTACHED TO METAL LATH ATTACHED TO UNDERSIDE OF TRUSSES RAT RUNS PER TRUSS MANF. (MAX. 8' O.C) 12 ���IIII � � 6 GARAGE BEYOND BUILDING SECTION A -A CONIC. COLUMN lx2 MIN. P.T. BUCK SET IN STRIPPING SEALANT AND NAILED W/ STUCCO FINISH CONIC. OR MASONRY �WEATHER BY DOOR MANF. 1-1/2" CASE HARDENED COIL PERIMETER SEALANT GARAGE DOOR NAILS AT 12" 0 C. MAX. / CONIC. OR MASONRY T. 2x6 P.BUCK RIPPED GALV. S7L. VERT. TRACK BY MANE. FASTENED TO TRACK BRACKETS W/_':.:..:` CONC. OR MASONRY °. ° . '.' :'q°::: 1x6 P.T. BUCK SET IN SEALANT AND NAILED W/1-1/2" CASE HARDENE TO WIDTH OF DOOR JAM SET IN SEALANT FASTEN W/ 1/4" DIA. x 3-1/4" TAPCONS 3" FROM E.E. COIL NAILS AT 12' 0 C. 1/4"-20x1/2" CARRIAGE q° ° / �q° 0 AND 6" O C MAX. ° / BOLTS & LOCK NUTS DRYWALL BOARD °00 MAX. °° Q GALV. STL. TRACK CAULKING DOOR TRIM BRACKETS FASTENED TO WOOD JAMB - �ALUMINUM FRAME, FASTEN DRYWALL BOARD DOOR FRAME 3/16"af-i/4" LAG SCREWS G TO STRUCTURE THRU BUCK W/ 3 i6" TAPCON SCREWS CAULKING FASTEN TO BUCK W / GALV. x 2" 2x8 P.T. ATTACHED TO MANU.'S METHOD OF COLUMN W/ 5/8" WEDGE 0 12' 0/ C. MIN. 1-1/4" EMI D DOOR FRAME FASTEN TO BUCK W/ S SC CREWS ®2' -0" O/C ATTACHMENT SHALL ANCHORS ® 2'-0" 0/C VERT. EPAIL MIEN SUBMITTED ERIMETER SEALANT (2) 3/16"x2-1 2"TAPCON DOOR TRIM FROM W/ COMPLETE INSTRU 11C (6" MAX. FROM ENDS) AND STUCCO FINISH SCREWS 0 2'-0'0/C PERIMETER SEALANT 2' FROM EDGE OF 2X8 HEAD DETAIL (WINDOW) JAMB/HEAD DETAIL (S.G.D.) STUCCO FINISH JAMB DETAIL (GARAGE DOOR) WINDOW ATTACHED ACCORDING TO FBC 1707.4.4.2 HEAD/JAMB DETAIL (DOOR) IF GARAGE DOOR VERTICAL REINFORCEMENT ALUMINUM FRAME, FASTEN REQUIRED, ADD (1) f" A.B. TO EACH SIDE OF THE TO STRUCTURE THRU BUCK DOOR THRESHOLD SET BRACKET THRU THE HORIZONTAL 2X P.T. HEADER, 4" MIN. EMBED MAX. 6" FROM EACH SIDE OF THE W/ 3 16' TAPCON SCREWS 0 12' 0/C. MIN. 1-1/4" EMBED ALUMINUM FRAME SECURE FRAME TO SILL OOR FRAME FASTEN IN BED OF CAULK & BRACKET. PERIMETER SEALANT STUCCO FINISH WITH SILICONE CAULKING TO BUCK W/(2) 3/16"x 2-1/2" TAPCON8 SCREWS 0 2'-0" O/C FASTENED TO SILL W/ x 1 1/2" SCREWS 0 18" O/C �- PERIMETER SEALANT CONIC. OR MASONRY FLOOR COVERING 0 lx2 MIN. P.T. BUCK SET IN -- ��O o ° . 'o a FLOOR COVERING SEALANT AND NAILED q" Ob. °.0 IF PO o W 1-1 2" CASE HARDENED COIL NAILS AT 72" 0/C. >�MAX. PRECAST OR POURED SILL W/ 1 #5 BAR +`b°O° °oq O. ° DRYWALL BOARD GROUT BED CONIC. FLOOR SLAB CAULKING PERIMETER SEALANT CONCRETE SLAB PERIMETER SEALANT JAMB DETAIL (WINDOW) SILL DETAIL (WINDOW) SILL DETAIL (S.G.D.) STUCCO FINISH SILL DETAIL (DOOR) WINDOW ATTACHED ACCORDING TO FBC 1707.4.4.2 WINDOW ATTACHED ACCORDING TO FBC 1707.4.4.2 1 0'-0" FIN. FL. SLA T.O.B.B. 1 T.O.B.B. T.O.B.B. -0" FIN. FLOOR PROJECT LOG ISSUED FOR PRECON 03-23-18 ISSUED FOR PERMIT 04-24-18 LIJ a. m t° 0 m o LIJ N J P W J a ,., J Z y Q w 0 m LL W x LL w z J J 0 Z 0 m Z 0 a 0 �4 O 01 Ln 01 @�1= U Q 0 T o .� o 41 n U V a �6 E_ O cu CU o E a o c + � E E o R a 0 0 +� E V L � � ° > acri o c6� E cn Q' c o = v� v"i O LL.I -aE o E � L Z o ( �fu z a s cU o C O H J � LL a 0 U n � ILL, N 0 0 U I J O W 1/4" = 1'-O" U.N.O. SECTIONS ELEVATIONS NOTE: IN THE EVENT THAT THE R.O. IS LAID OUT LARGER 1HAN THE PROPOSED OPENING ON PLANS. THE CONTRACTOR SHALL BE ALLOWED TO SHIM THE OPENING, USING A (-OMBINATION OF 2x & 1x PRESSURE TREATED LUMBER. THE FRAMING SHOULD BE SECURED TO THE BLOCK USING THE PROPER TAPCON LENGTH, DIAMETER & SPACING FOR MINIMAL EMBED REQUIRED AS NOTED PER PLAN. MW m 277 ENG. AND APPROVED WOOD TRUSSS SEE TYR WALL SECTION FOR ACTUAL HEEL AND OVERHANG CONDITIONS SEE TRUSS CONNECTOR SCHEDULE SELECT CONNECTOR BASED ON LOADS SHORN ON FRAMING PLANS INSTALL PER. MFR. SPECIFICATIONS SEE PLAN ggh Nw 4'-0' CONE MASONRY BOND BEAM CONT. POUR STOP 8" CMU WALL 1 A5 CONNECTION DETAIL ENG. AND APPROVED WOOD TRUSSS SEE TTP. WALL SECTION FOR ACTUAL HEEL AND OVERHANG CONDITIONS SEE TRUSS CONNECTOR SCHEDULE SELECT CONNECTOR BASED ON LOADS SHOWN ON FRAMING PLANS INSTALL PER. MFR. SPECIFICATIONS NOTE IF TWO STRAPS ARE USED PLACE ONE STRAP EACH SIDE. CONT. MASONRY BOND BEAM 8" CMU WALL 2 AS CONNECTION DETAIL p USP KCCQ44 OR h SIMPSON CCQ44sds2.5 FASTEN PER MAN'F. SPECS I 56801 MAX. _L WOOD POST SEE FRAMING PLAN (6) 1/4"x2-1/2" LG, SDS SCREWS TO POST SI HOLDSON DOWNU56451 MAX (i) 5/8" DIA. WEDGE ANCHOR 4" MIN. EMBED. A5 CONNECTION DETAIL NAIL SILL PLATE THROUGH TO CROSS BLOCK W/2-16d NAILS AT EACH TRUSS FRAME KNEE WALL 2x4 STUDS ® 24" 0/C W/ 19/32" EXT. SHEATHING TOE NAIL TRUSS TO CAP W/3-16d NAILS PRE-ENG. WOOD TRUSSES \ SEE TYP, WALL SECTIONS ACTUAL HEEL AND OVERHANG CONDITIONS 2x4 CROSS BLOCK 0 24"- O/C TYP. TOE NAIL EA. END W/(3) 16d NAILS TYPICAL TRUSS TIE BEAM OR BOND BEAM CONT. 2x4 RIBBON W/ 3-i6d NAILS EA. STUD A5 CONNECTION DETAIL ALLOWABLE LOAD 1061 #/TRUSS UPLIFT NOTE: MAY BE ATTACHED TO VERICAL TRUSS MEMBER FOR DESIRED INSTALLATION DUE TO TRUSS PROFILE DISCREPANCIES (1) 5/8' ANCHOR INTO BEAM W/ 5" MIN. EMBED. SET IN EPDXY PRE-ENGINEERED WOOD ROOF TRUSS 0 24" 0/C SIMPSON MGT W/ 22-10d NAILS INTO TRUSS 'ONC. TIE BEAM OR WASONRY BOND BEAM MAX. UPUFT = 3965# 4CONNECTION DETAIL 1/4' THICK PLATE HANGER 4" N 3/16" e N (2) 1/2" DIA. THROUGH BOLTS WEDGGE)ANCHORSDW/ 4" MIN. EMBED. a5 CONNECTION DETAIL PER TRUSS MFR. "LOTTS" LINTEL BEAM SCHEDULE 1B/FT LINTEL LENGTH ALLOWED LOAD APPLIED LOAD ALLOWED UPLIFT PPLIED JPLIFI LINTEL SPECIFICATION 1 17'-4" 1413 545 581 240 BF24/1B1T 2 5'-4" 10000 257 5698 106 8F44/iB1T 3 4'-0" 8859 250 5572 100 8F16/1B1T 4 5'-4" 5809 250 3057 100 8F16/1B1T 5 5'-4" 5809 250 3057 100 8F16/181T 6 S-6" 10000 1057 9578 371 BF40/1B1T 7 4'-0" 10000 0 7184 0 8F38 1B1T 8 5'-4" 1773 0 1135 0 8F8/1B1T 9 5'-4" 5809 946 3057 380 8F16/iBiT 10 4'-0" 2866 0 1753 0 8F8 1B1T 11 4'-0' 8859 1222 5572 365 8F16 18lT 12 4'-0" 10000 920V 331 8F38/iB1T 13 13'-4" 504 0 0 8F8/1BiT 14 13'-4" 2047 1611 621 8F24/1B1T 15 4'-0" 10000 ffid -e- dit -4;I. 8RF38/1BiT 16 10'-6" 1664 250100 8F16/1B1T 17 3'-6" 10000 408 133 8F16/181T 18 7'-6" 2882 771 4 308 8F16/191T 19 5'-4" 10000 400 6183 177 8F44/iB1T 20 5'-10" 1002 0 722 0 8RF6/1BOT 21 5'-10" 10000 462 5480 220 8F32/181T 22 S-O" 10000 376 9578 250 8F64/1B1T 23 7'-6" 8615 1123 2879 412 BF28/1B1T 24 S-6" 1 10000 1 390 1 9578 1 233 1 BF54/1131T 25 7'-6" 6288 250 2436 102 8F24/1B1T 28 3'-6" 10000 390 9578 233 8F54/1131T 27 4'-0" 10000 765 7184 283 8RF34/1B1T 1/2" DRYWALL OVER TYPICAL FURRING EXTRA LATER OF 1/2' DRYWALL SURRONOING FRAME ARCH TYPICAL FURRING APPLIED TO SHEATHING 19/32 PLYWOOD ARCH SECTION 5 a5 CONNECTION DETAIL W A, A5 BOX -OUT DETAIL SCALE: I4 = 1-0 N CONT. 2x6 P.T. BUCK FASTENED TO LINTELS W/ 1/470" LG. TAPCONS 0 12" 0/C MAX. AND TO BLOCK OR CONC. W/ HILTI DNI-62-P8 0 8' 0/C MAX. 1 2X6 P.T. CROSS BLOCK REQUIRED ONLY IF FREE EDGE DIMENSION EXCEEDS 24" SEE DIMENSION. NAIL TO BUCK AT EACH END W/ (4) i6d NAILS. Ww, PRE-ENG 0. TRUSSES ® 24" (SEE CONNECTION SCHE6 19/32" EXT. GRADE PLYWD. NAILED ® 6' 0/C AT PANEL EDGES & 12" 0/C FOR THE REMAINING FIELD W/ 10d NAILS 1x8 VERTICAL. NAILED TO ROOF TRUSS W/ (3)10d NAILS, NOTCHED AND TOENAILED W/ (3) 10d NAILS TO PLYWOOD ON BLOCK WALL. (3)i/2"x6" PCS. EXTERIOR PLYWOOD CUT TO CONTOUR OF ARCH, SHOT TO WALL W/ 3' PINS 0 12' 0/C (1 i14' EMBED) EDGE OF MASONRY OPENING 19/32 EXTERIOR SHEATHING W/PAPERBACKED HI RIB METAL LATH 2X4 PT BLOCKS ALONG ARCH NAIL TO PLYWD. EACH END W/(3) 10d x 1-i12' COIL NAILS SECTION aim aim mai mcd ad ai a5 m m cd 00 00 00 cs6 vv a 8F1 NOMINAL HEIGHT QUANTITY OF #S NOMINAL WIDTH REBAR AT TOP K TYP. 0 WALLS 8U8 8F16-OB/1T 8F16-lB/lT 7-5 8' ACTUAL " NOMINAL HEIGHII 8F24-OB/lT 8F24-18/1T 8F30-1B/lT PROJECT LOG .ISSUED FOR PRECON 03-23-18 ISSUED FOR PERMIT 04-24-18 w a: 8 Lu 0 W a LLI N z M W Z K Ld U < cn Z < a Z0 Oa o � w 0 cm rn = c c o- O c rn a� o 0 v a+ E 4' o _ w v rn a L a E o_. O co a ou (v E E o � o cu Cr CID n o O V E Ln Q' c aj c o = U� u E o o -tf C7 z " v t N--Ln O�N_. o � J a V u O O u3 N 0 u 0 � J o LJJ Lo 1/4" = 1'-0" U.N.O. STRUCTURAL PLAN A5 MW 277 PROJECT LOG ISSUED FOR PRECON 113-23-1-8�I ISSUED FOR PERMIT 04-24-18 �F Nm j 730 LBS. MAX. N r- 1235 LBS. MAX. 10 LBS. a f' �� '� �r w Lit x0 TC-i (2) TC-1 TC-2 O m WALL HEIGHT CHAN 3E WALL HEIGHT CHANGE 0 NOTE: THIS TYPICAL DETAIL TO BE USED WHERE CONDITIONS MAY OCCUR BASED ON TRUSS DESIGN AND FIELD CONDITIONS TYP. RIDGE CAP & ROOF MEMBRANE �— 2x RIDGE BOARD (2) SIMPSON H10 CLIPS ON 1 SIDE OF TRUSS STAGG. & ATTACHED TO 2x6 CATS ® 24' O/C BETWEEN TRUSS RUN PRE ENGINEERED ROOF TRUSSES SEE FRAMING PLAN FIELD FRAMED RIDGE DETAILI a: �E�DGE STRIP DEFINED AS THE LESSER O�F� 10% OR 40% OF HEIGH HL BUTNNOT LE SBIHAN % OF LEAST HORIZONTAL DIMENSION OF BUILDING AND AT LEAST 3 FT. NOTE: SEE DIAPHRAGM SCHEDULE FOR ROOF ZONE NAILING REQUIREMENTS. O O ROOF ZONE DIAGRAM O TRUSS CONNECTOR SCHEDULE FASTENERS RTRAP PER ALLOWABLE UPLIFT PARALLEL LOAD (172) PERPEND. LOAD (F1) MARK USP CONNECTOR TRUSS TIE -BEAM OR WALL SINGLE STRAP DOUBLE STRAP SINGLE STRAP DOUBLE STRAP SINGLE STRAP DOUBLE STRAP TC-1 TA12 5 fOd x 1-1 2" - 990 j 1980 335 f 1 670 2451 490 TC-2 TA14 7) 10d x 1-1 2" - 1205 j 2410 1 335 1 670 j 245 1 490 TC-3 HTWM16 8 10d x 1-1 2' 4 1 4" x 1-3 4' WAD. 1225 1 - 1225 j - 25 - TC-4 HTA16 9 10d x 1-12' - 1870 2430 710 1215 TC-5 HTW20 20 10d x 1-1 2' 24 10d x 1-12' 1530 - - - - gL70 1) ALLOWABLE LOADS ARE BASED ON USP CATALOG 2015-16. 2) BLDR MAY USE LONGER STRAPS OF SAME TYPE SPECIFIED, 3) USE GALVANIZEI SCREWS AS SPECIFIED BY MANUFACTURER, 4) TAPCONS SHOULD BE LOCATED AT THE FARTHEST POINT FROM THE TOP OF THE BEAM. RING —SHANK NAILS TO HAVE THE FOLLOWING DIMENSIONS- 1. 0.113 INCH NOMINAL SHANK DIAMETER 2. RING DIAMETER OF 0.012 OVER SHANK DIAMETER J. 16 TO 20 RINGS PER INCH 4. 0.280 INCH FULL ROUND HEAD DIAMETER 5. 2 INCH NAIL LENGTH DIAPHRAGM SCHEDULE (FASTENING REQUIREMENTS PER R803.2.3.1) DIAPHRAGM NAILING DIAPHRAGM ZONE i I ZONE 2 ZONE 3 PANEL FRAMING BOUNDARIES EDGE INTER, EDGE INTER. EDGE INTER. LOCATION PANEL GRADE THICKNESS SPACING REMARKS ROOF APA RATED SHEATHING 8d RING- 8d RING- Bd RING- 8d RING- 8d RING- 8d RING- 8d RING - EXPOSURE I, OR EQUAL SPAN RA71NG 40120 19 32" 24" 0/C MAX. SHANK 6' 0 C SHANK 6" O C SHANK 6' 0 C SHANK 8" 0 C SHANK 6' 0 C SHANK 4" 0 C SHANK 4' 0 C BLOCKED AS SHOWN ON PLAN EXT. WALL APA RATED SHEATHING EXPOSURE I, OR EQUAL SPAN RA77NG 40120 19/32 1 16" 0/C MAX. 8d RING- SHANK 4' 0 C 8d RING- SHANK 4" 0 C Bd RING- SHANK 6' 0 C NAIL CORNER STUDS AT 4" 0/C MAX. TYPICAL BLOCK FREE EDGES APA RATED SHEATHING 8d RING- 8d RING- 8d RING- INT. WALL EXPOSURE 1, OR EQUAL SPAN RA71NG 32116 15/32 16" O/C MAX. SHANK 6' 0 C SHANK 6" O C SHANK 12" 0 C BLOCK FREE EDGES CONNECTIONS, U.N.O. HEIGHT CHANGE 238 LBS. ® 48" O/C '980 LBS. TAIL 3/A5 is 23 I.0 LBS. E.E. K 9'-4" PLATE HT. 10'-8" PLATE HT. 11'-4" PLATE HT. PLATE HT. 14'-0" PLATE HT. Hardware Quantity HUS26 16 Indicates Left End Of Truss On Layout & Engineering Sheets 61- 4-3/16" 8" cmu 2,_o„ Wall Typical End Detail w/ Level Return w a: 0 a o U Uj a w Z w J J w Z h � O ¢ m� m w a " utOi Z c 0 pa 0 4 o- -�6o __ � CL a� �-E5o O -0 -a U Ln N -0 (v o c aj vi c r`o c 3 5= a c rn o CU —�- Eca cco o aci o 4:5; c cc Q o E E o m o + Id d O -0 Q U (D ` 01 Cr c o V t tn a) E :E, o Cn � �' c o x rj c V o ~ O V N V vAi (.7 Z Qj�E O a� O a rav� = 1'-01, P/8 E Q i L O r r h LO CN h h J LL z 0 w U J C TRUSS PLAN w MW=277 PROJECT LOG ALL VANITY LIGHTS TO BE 100" A.F.F =15" ITCH'S TO DR. FRAME GARAGE DOOR OPENER TO BE 5'-0" A.F.F. NOTE: ACCEPTABLE SMOKE 'C CARBON DETECTORS TO BE INSTALLED ARE BRK SMOKE-91208 C/O—SC9120B KIDDE SMOKE-21007581 C/O 21006377—N NOTE: PROVIDE ARC —FAULT CIRCUIT INTERRUPTER PROTEC11ON FOR ALL RECEPTACLE AND LIGHTING OUTLETS INCLUDING SMOKE DETECTORS PER 2017 NEC 210-12 (B) Plans are Prepared for the Builder and not any Planned or Future user / Home owner of the Subject Property and any Modifications, Deletions and other Changes Authorized by GHO Homes Corporation or other GHO entity are Permissible to included, but not be limited to Electrical Design Modification, Fixture or Outlet or Circuit changed, Combinations or Changes. All Final Work shall be at a minimum Equal to Code minimums and any changes are only Permissible if Suggested and complete by a licensed Electrician so long as Applicable Codes are Met and Load Sufficient to Meet GHO's minimum Level of Service and Operation. ELEC. PANEL "A" 200 AMP CIRC. DESCRIPTION POLE BRKR WIRE VA. 100% 2 AHU HEAT STRIP 2 60 6 0 9.6 2 A/C COMPRESSOR 2 40 8 0 0 1 ELECTRIC COOKTOP 2 50 6 10.0 0 1 WALL OVEN 2 50 6 10.0 0 2 DRYER 2 30 10 5.0 0 2 WATER HEATER 2 30 10 4.5 0 1 WASHER 1 20 12 1.5 0 1 MICROWAVE 1 20 12 1.5 0 1 DISHWASHER 1 20 12 1.2 0 1 REFRIGERATOR 1 20 12 1.2 0 3 SMALL APPLIANCE 1 20 12 4.5 0 1 BATH GFI 1 20 12 1.5 0 12 GEN. LIGHTING 1 15 14 5.7 0 FM' 11111M. l 1st 10,000 at 100% = 10.00 REMAINDER AT 40% = 14.64 A/C LOAD AT 65% = 6.24 TOTAL = 30.88 30.88 x 1000/240 = 128.7 AMPS (1) SETS OF (3) 14/0 AWG. THAN IN 2" CONDUIT 200 AMP SERVICE p METER DISC. CO PANEL 200 A 5/8" GDX 10' CU SUPPLEMENTAL GROUND ROD AND TO ONE REINFORCEING BAR IN THE FOUNDATION 20'-0" LONG MIN, ELECTRICAL RISER DIAGRAM CALCULATION NOTES: A. HEAT STRIP LOAD GOVERNS OVER CONDENSER UNIT LOAD. B. GENERAL LIGHTING CALCULATED 0 2284 (SQ.FT.) x 3 (WATTS/SQ.FT.) = 6852 / 12 (GEN.LTG.CIR.) = 571 (WATTS/EA.) C. A/C CONTRACTOR SHALL SIZE A/C UNITS. A/C UNITS SHOWN ARE FOR ELEC. CALC S. ONLY. (1) CAT 5e (1) RG6 (PER TV LOCATION) DED. OUTLET ❑ INSIDE FOR PANEL PM T SMART PANEL fU111,70 i 11I LOW VOLTAGE GHO 11SMAR I IISSUED FOR PRECON 103-23-181 ISSUED FOR PERMIT 1 04-24-18 1 W d = 0 CP o a Lu W p Z W J W m Z N r M "' LL U F a " LL Z J e a d, y p Z d 0 0 LL 0 a,ar@ o-o @ 15 0 o o n T — =3 o .o' W Ln o O 0 N °'�_�� �>_WQC, O o CEru `�' o ra p- 4'.9 V N E E O@ p 0 d s w oi O +� 30E O c!1 rn n 0 N C) 0 @ Z U CL no U O ai aJ Z r_ • 0 0^ Ln QU 20 0 U O C — r C L v 0LO J N 1g: of 0 O F�. J LL � a � o 0U 0 n 0 U N ::D J ' W 1/4" = 1'-0" U.N.O. ELECTRICAL PLAN E-1 w-277 2" VTR Jib 3" 3" 2" SHWR� . WC 2- 2- 3" 3• LAV LAV AVV CO �— 3" 2• 2" CO 2" 3" 2. TUB 2" LAV TUB MASTER BATH 3" BATH 2 3 wr 3" PLUMBING RISER DIAGRAM KITCHEN kl- 2" 3" 2" VTR AVV LT CO LAUNDRY WM 2" AVV LAV T WC OW,J 2" SHWR CABANA Vs" 2a 7 i 321b DENT FINE DKIVE F KT rIEKCE, FL 34951 PROJECT LOG ISSUED FOR PRECON 03-23-18 ISSUED FOR PERMIT 04-24-18 W 0 � m o W 'e n J W a ui Lij ::) < Q w M LL LL W Z O CL w U o Q a co � Z 0 Qa 0 0 a c a a =�E.�oN� ro c _ (u .� O -0 = aj E 0- Z 6 o c aci o c z w E E o a o o E 2 fl-v c p N O U� E i N cn +� =O _ (!) C vi a) v�i O W (D r6 i = Z O Q ra L U a) aD _0 Q _ O FV�I J LL � r Z O W CV Q 0 U J O W 1/4" = 1'-0" U.N.O. MECHANICAL PLAN M-1 MW = 277