HomeMy WebLinkAboutEVALUATION REPORTSCANNED BY St Lucia CountV QOTRINITYIERD EVALUATION REPORT Boral Roofing 7575 Irvine Center Drive, Suite 100 Irvine, CA. 92618 (602)269-2288 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization ##9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report FL14317-R8 Date of Issuance:12/21/2010 Revision 9: 10/14/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and t I e applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compljance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until s� ch time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded bl the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Repot is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation its distributors and shall be available for inspection -at the j This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or 1 distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any compa 3. Robert Nieminen, P.E. does not have nor will acquire, a financi which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does, not have, nor will acquire, a financ product. 5. This is a building code evaluation. Neither Trinity IERD nor RI project on which this Evaluation Report, or previous versions t specifically for that purpose. CONCEALED FASTENERS OR Al ARE THE RESPONSIBILITY CONTRACTOR OR REO FILE C port shall be provided to the user by the manufacturer or site at the request of the Building Official. _-ST. LUCIE COUNTY BUILDING DIVISION % REVIEWED FOR COMPLIANCF� '': REVIEWED BY S AND PERMIT MUST BE KEP ON JOB OR NO INSPECTION(S) WILL BE MADE ai •��.• The facsimile seal appearing was authorized by Robert ;woo Nleminen, P.E. on 10/14/2017, This does not serve as an electronically signed document. fill it acquire, a financial interest in any company manufacturing or ly manufacturing or distributing products it evaluates. l interest in any company manufacturing or distributing products for al interest in any other entity involved in the approval process of the bert Nieminen, P.E. are, in any way, the Designer of Record for any lereof, is/was used for permitting or design guidance unless retained THE THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS py REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Boral Roof Undlerlayments, as with the following sections of the 6th Edition (2017) FI following Standards. Compliance is subject to the Instal forth herein. 2. STANDARDS: Section 1504.3.1 1507.1.1, T1507.1.1, 1507.2.9.2 1507.3.3 3. REFERENCES: En_, tits ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) UL, LLC. (QUA 9625) 4. PRODUCT DESCRIPTION: I Property Wind Uplift Physical Properties Physical Properties I i Examination Physical Properties Physical Properties Tensile Adhesion / LTA Adhesion Tensile Adhesion / LTA Tensile; Adhesion / LTA ASTM D1970 ASTM D1970 Tensile Adhesion / LTA FRSA/TRI April 2012 ASTM D1970 Wind Uplift Wind Uplift Quality Assurance I 4.1 Self -Adhering Underlayments': 4.1.1 Boral TileSeal® 50"T is a nominal 50-mil thi „,I TRINITY I ERD marketed by Boral Roofing, have demonstrated compliance orida Building Code through testing in accordance with the Ilation Requirements and Limitations / Conditions of Use set Standard UL 1897 ASTM D1970 FRSA/TRI April 2012 (04-12) Reference M36790.07.11 1340380.08.12 C41420.09.12-2 B41940.09.12 B47390.07.14-1 1347390.09.14 NEI-031-02-02:REV NEI-029-02-01:REV NEI-046-02-01REV NEI-076-02-01 NEI-034-02-02 BORR-001-02-01 BORR-005-02-01 Service Confirmation Year 2012 2015 2012 Date 09/30/2011 08/28/2012 09/11/2012 09/13/2012 07/31/2014 09/04/2014 10/27/2010 12/03/2010 12/17/2010 02/14/2011 01/29/2013 03/17/2015 06/24/2015 Exp.08/21/2020 polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. 4.1.2 Boral TileSeal® "T is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI 04-12. 4.1.3 GatorSeal® is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D11970. 4.1.4 Citadel® Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roofing underlayment for use as a base -layer in two-ply underlayment systems; meets ASTM D1970. S. LIMITATIONS: 5.1 This is a building code evaluation. Neith( Designer of Record for any project on whi used for permitting or design guidance unk 5.2 This Evaluation Report is not for use in FBC Exterior Research and Design, LLC. Certif sate ofAuthoriration #9503 TrinitylERD nor Robert Nieminen, P.E. are, in any way, the this Evaluation Report, or previous versions thereof, is/was retained specifically for that purpose. jurisdictions. 6T” EDITION (2017) FBC NON-HVHZ EVALUATION Boral Roof Underlayments; (602) 269-2288 Evaluation Report M35710.12.10-R9 FL14317-R8 Revision 9: 10/14/2017 Page 2 of 7 5.3 5.4 5.5 5.5.1 5.6 PTRINITYIERD Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Boral Roof Underlayments may be used wit any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. Allowable Roof Covers: Table 1 pertains to Use of each listed underlayment by -itself beneath the stated roof covers. Refer to the installation instructions and Table 2 for two-ply underlayment options. 1� ROOF COVER;OPTION$ STABLE .z 1,A�R d`3..2'. Asphalt Adhesive -set Wood Shakes Underlayment Nail -On Tile Metal Slate Shingles Tile & Shingles BoralTileSea150Yes No Yes ` Yes Yes' No ;� km Yes Boral TileSeal"T Yes Yes Yes Yes Yes 5 (See 5 1) GatorSeal " ,. "Adhesive -set Tile" is limited to use of following Approved tile adhesives / underlayment combinations. TAgUTA ALLQWABLETILEI DHESIV" e .'TILIiNDERLAYMENT"COMBINATIUN51 s. Adhesive I Florida Product Approval Underlayments DAP Foam Touch'n Seal StormBond Roof Tile Adhesive FL14506 Boral TileSeal"T Dow TILE BOND'"' Roof Tile Adhesive FL22525 Boral TileSeal"T ICP Adhesives Polyset® AH-160 I FL6332 Boral TileSeal"T ICP Adhesives Polyset® RTA-1 FL6276 Boral TileSeal"T Allowable Substrates: 5.6.1 Direct -Bond to Deck: Citadel Plus, Boral TileSeal 50"T, Boral TileSeal"T or GatorSeal: ➢ Plywood (unprimed or primed with ASTM D41 primer). Boral TileSeaIHT: ➢ OSB primed with ASTM D41 primer. Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the overlying roof cover is adhesive -set #ile roofing 5.6.2 Bond to Base Laver Underlayment: Citadel Plus, Boral TileSeal 50HT, Boral TileSe ➢ ASTM D226, Type II felt; Citadel Plus. For installations under mechanically attache( minimum codified requirements. For install attached per minimum requirements of FRSA Section 5.6.4 herein, or as tested in accordant I"T or GatorSeal: prepared roof coverings, base layer shall be attached per :ions under adhesive -set tile systems, base layer shall be rRl April 2012 (04-12), Appendix A, Table 1, or as listed in with FBC 1504.3.1. 1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Pi oduct Approval for Overturning Moment Resistance Performance. Exterior Research and Design, I.I.C. Evaluation Report M35710.12.10-R9 Certificate of Authorization #9503 67" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-RB Boral Roof Underlayments; (602) 269-2288 Revision 9:10/14/2017 Page 3 of 7 9TRINITYIERD 5.6.3 Bond to Other Substrate Types: Citadel Plus, Boral TileSeal 50"T, Boral TileSeal"T or GatorSeal: ➢ ASTM D41 primed metal (e.g., flashing I etal, valley metal, etc). Boral TileSealHT: ➢ Huber Zip Deck (unprimed or primed wi h ASTM D41 primer); Dens Deck Prime. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. 5.6.4 Wind Resistance for Underla ment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of al underlayment systems beneath adhesive -set tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads #1 Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood o meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: (Optional) Citadel Plus, self -adhered Underlayment: Boral TileSeal"T, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #2 Maximum Design Pressure = -120.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the plywood deck Base Ply: Citadel Plus, self -adhered Cap Sheet: Boral TileSeaIHT, self -adhere , and back -nailed within the selvedge -edge side laps using 12 ga. x 1%n ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure = -202.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the plywood d ck Base Ply: None Cap Sheet: Boral TileSeal"T, self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -120.0 psf: Deck: Min. 2,500 psi structural cl ncrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the concrete deck Base Ply: (Optional) Citadel Plus, self-ldhered Cap Sheet: Boral TileSealHT, self -adhered 5.6.4.1 Note: For adhesive -set tile systems, if there 1 s a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. Exterior Research and Design, I.I.C. I Evaluation Report M35710.12.30-R9 Certificate ofAuthorizotion #9503 67H EDITION (2017) FBC NON-HVHZ EVALUATION F1.14317-118 Boral Roof Underlayments; (602) 269-2288 Revision 9: 10/14/2017 Page 4 of 7 (gTRINITYIERD 5.7 Exposure Limitations: GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final roof cover. Boral TileSeal 50"T and Boral TileSeal"T s I all not be left exposed for longer than 180-days after installation, prior to placement of final roof cover. Citadel Plus, for use as a base -layer in a two-ply underlayment system, shall not be left exposed for longer than 180-days after installation, prior to placement of subsequent underlayment layer. 5.8 When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can orjly be exceeded by using battens during loading of the roof tiles. ..y TABLE 2 TILE SUPPAGELIMITAT(ONS FOR' DIRECTQECK TILE INSTALLATIONS'` T, Underlayment Tile Profile Stagging Method Maximum Slope Flat Max. 10-tile stack 6:12 Boral TileSealIT Lugged Max. 10-tile stack 6:12 6. INSTALLATION: 6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions subject to the Limitations set forth) in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly I to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40°F and rising. 6.4.1 Citadel Plus is limited to use as a base or id -layer in multi -ply underlayment systems beneath Boral TileSeal 50"T, Boral TileSeal IT or GatorSeal. 6.4.2 Slope limitations are those associated with the top -layer underlayment. 6.4.3 Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch. Fold the memlbrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Boral recommends fastening of the top edge of the sheet to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses minimum 2 inches (horizontal lap) and minimum 4" end (vertical) laps. Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"T, Boral TileSealIT or GatorSeal. 6.4.4 To Base Sheet: Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part of a multi -ply system. Install optional Citadel Plus as a mid -ply In accordance with Boral Roofing published installation instructions and Section 6.4.3. Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"T, Boral TileSealIT or GatorSeal. Exterior Research and Design, I.I.C. Evaluation Report M35710.12.10-R9 Certificate ofAuthoriration #9503 6T" EDITION (2017) FBC NON-HIVHZ EVALUATION FL14317-R8 Boral Roof Underlayments; (602) 269-2288 Revision 9:10/14/2017 Page 5 of 7 . r TRINITY 1 ERA Note: For adhesive -set tile systems, if therelis a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. 6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof coverinlg to be installed. 6.5.2 Do not use Boral TileSeal 50HT on roof pitches lMess than 2:12. 6.5.3 Non -Tile Applications, Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch. Fold the me i brane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Boral recommends fastening of the black selveI-dge edge to the deck with roofing nails, nails & tin -tags or f- inch diameter plastic or steel cap nails spaced L4-inch o.c. for slopes below 7:12 and 12-inch D.C. for slopes 7:12 and greater. Overlap successive courses tllhe width of the black -selvedge area, minimum 3-inch. Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. 6.5.4 Non -Tile Applications, to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSeal 50HT in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing published installation instructions and Section 6.5.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. 6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.6.2 Do not use GatorSeal on roof pitches less than 2:12. 6.6.3 Non -Tile applications, Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1- inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses t�e width of the black -selvedge area, minimum 3-inch. Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self - adhering bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a weighted roller, or using the' Inverted Sheet Seam detailed in Boral Roofing published installation instructions. 6.6.4 Non -Tile Applications, to Base Sheet: Install ASTM D226, Type II felt in accordance vv'ith Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install GatorSeal over ASTM D226, Type II felt �or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.6.3 except end (vertical) laps, described below. Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the granular top sulrface, rolling the interface into place with a weighted roller. Exterior Research and Design, I.I.C. I Evaluation Report M35710.12.10-R9 Certificate ofAuthorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-118 Boral Roof Underlayments; (602) 269-2288 Revision 9:10/14/2017 Page 6 of 7 / Kr 6.7.1 Shall be installed in compliance with the re'quirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.7.3 Non -Tile Applications, Direct to Deck: For OSI3 substrate, prime with ASTM D41 p, in�er and allow to dry prior to installation. Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by X-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Boral recommends fastening of the black selvJ I dge edge to the deck with roofing nails, nails & tin -tags or 1- inch diameter plastic or steel cap nails spaced I 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. overlap successive courses the width of the black -selvedge area, minimum 3-inch. Seal under end (vertical) laps using approvedl mastic, or use Joined and Folded Seam or inverted Sheet Seam method detailed in Boral Roofing publis ed installation instructions. 6.7.4 Non -Tile Applications, to Base Sheet: `1 Install ASTM D226, Type Ii felt in accordance �ith Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSea over ASTM D226, Tyge 11 felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below, Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surfaice, rolling the interface into place with a weighted roller. 6.7.5 Tile Applications: Reference is made to FRSA/TRI April 2012 4-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less ihan FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSea I HT with roof pitches of 2Y2 to less than 3:12. Boral Roofing's Elevated Batten System or counter battens are required. 7. 8uLomG PERMIT Asrequired bythe Building Official nrAuthority Having Jurisdiction inonde,topropedyeva|uatetheinstaUaUonof this product. | | 8. KNAmupAcTummG PLANTS: Brentwood, NH 9, QUALITY ASSURANCE ENTITY: UL,LLC.—[}UA95Z5;(631)S46'245D; 'END OF EVALUA 1014 REPORT ' i Exterior Research and Design, mc Evaluation Report M3571012.10-R9 cer4aatewwuthouzammxsO3 o'^EDITION (2017) FBC NON-H Z EVALUATION pu4317-n8 Boral Roof unnwnavments/ 269-2288 Revision y'zu/z4/2oz, Page 7oor 1(a/2018 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL # 24221.1 Florida Building Code Online M thod 1 option D 10120 2017 10720/2017 10/26/2017 12/12/2017 Model, Number or Name Dynamic Metals 1" Nailstrip Description Ga 1" Nailstrip, 26 Ga Galvalume Steel, Non-structural roof panel Limits of Use Installation Instructions Approved for use In HVHZ: No FL24221 RQ 11 17-296,10 DWG,pdf Approved for use outside HVHZ: Yes Verified By: Pedro De Figueiredo, 'P E. 52609 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-131.0 Evaluation Reports Other: Maximum fastener spacing 6" o/c FL24221 RO AL- R17-296 10.1)df Created by Independent Third Party: Yes 24221,2 Dynamic Metals 1-1/2" Mecha (Aluminum) Ica! 1-1/2" Mechanical Seam, O.Q32" Aluminum, Non-structural roof panel ' Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL24221 RO II 17-296.02 DWG.Qdf Approved for use outside HVHZ: Yes Verified By: Pedro De Figueiredo, RE. 57-609 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-198.5 Evaluation Reports Other. -198.5 psf at maximum clip spacing 10-1/2" o/c FL24221 RO AE R17-296 2.odf -179.8 psf at maximum clip spacing 13" o/c Created by Independent Third Party: Yes 24221.3 Dynamic Metals 1-1/2" Mechanical 1-1/2" Mechanical Seam, 24 Gauge Galvalume Steel, Non- (24 Ga Steel) structural roof panel Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL24221 RQ 11 17-296.04 DWG.Ddf Approved for use outside HVHZ: Yes Verified By: Pedro De Figuelredo, P.E. 52609 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-171.0 Evaluation Reports Other: Maximum clip spacing 13" o/c. F1_24221 RO AE R17-296 4.odf Created by Independent Third Party: Yes 24221.4 Dynamic Metals 171/2" Mechanical 1 1-1/2" Mechanical Seam, 26 Gauge Galvalume Steel, Non- (26 Ga Steel) structural roof pane! Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL24221 RQ II 17-296.05 DWG,odf Approved for use outside HVHZ: Yes Verified By: Pedro De Figueiredo, P.E. 32609 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-221.0 Evaluation Reports Other: Maximum clip spacing 12" o/c FL24221 RO AE R17-296 5.pdt Created by Independent Third Party; Yes 24221.5 Dynamic Metals 1-1/2" Mechanical 1-1/2" Mechanical Seam, 16 Oz Copper, Non-structural roof (Copper) I I panel Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL24221 RO 11 17-296.06 DW(3.pc�f Approved for use outside HVHZ: Yes Verified By: Pedro De Figueiredo, P.E. 52609 Impact Resistant: N/A Created by )independent Third Party: Yes Design Pressure., +N/A/-198.5 Evaluation Reports Other: -198.5 psf at maximum clip spacing 12" o/c -153.5 psf FL24221 RO AE R17-296 6'pdf at maximum clip spacing 16" o/c created by Independent Third Party: Yes 24221.6 Dynamic Metals 1-3/4" Snaplock 1-3/4" Snaplock, 0,032" Aluminum, Non-structural roof panel (Aluminum) ' Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL24221 go II 17-296.09 DWG,pdf Approved for use outside HVHZ: Yes Verified By: Pedro De Figueiredo, P.E. 52609 Impact Resistant: N/A i Created by Independent Third Party: Yes Design Pressure: +N/A/-228.5 I Evaluation Reports Other: -228.5 psf at maximum clip spacing 9" o/c -168.5 psf FL24221 RO AE R17-296 9.Ddf at maximum clip spacing 19" o/c I Created by Independent Third Party: Yes 24221.7 I Dynamic Metals 2" Mechanical I 12" Mechanical Seam, 0.032" Aluminum, Non-structural roof https://www.floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDquUsDrhuM3DGM%2bmi7wFtl3%2fYFSE6n3NwN°/a2bZFHJBlBchAw%3d%3d 2/3 + . E. G C O Inc. 1791 Blount Road unit 907 Pompano Beach - Florida - 33069 Tel: (754) 307-1319 Fax: (754) 205-6845 Email: Engco@AOL.com 1.0 Product Manufacturer: 2.0 Code Edition: 3.0 Evaluation Method: 4.0 Product Classification: Dynamic Metals, LLC 340 Pike Road West Palm Beach, Florida Florida Building Code 201 Applicable for Non HVHZ Chapter15 Engineering Evaluation Category: Roofing Subcategory: Metal Roofing - non Not Applicable for HVHZ 5.0 Product Description: 5.1Trade Name: Dynamic Nailstrip 26 Gauge 5.2 Panel Properties: Material: Average Fy=64 ksi Panel Thickness: 0.0165" Coverage: 16" maximum width x vari Ribs Height: I" rib heigh mating with 5.3 Panel Clip Properties: Not available 5.4 Minimum Deck Requirements: I Date; 8117,'2017 REF.#: 17-2961 Q 1" NAILSTRIP 26 GAUGE STEEL PANEL 6th Edition 1D in accordance with 61G20-3.005 F.A.C. Panel s Ienghts 4" lower rib at 16' o.c. Minimum 15/32" 4 ply APA CDX plywood secured to 2x SYP with 8d ring shank nails spaced at 4"oc. 2x SYP joists spaced no more than 24"oc. Deck to be properly installed as per the FBC requirements •over minimum Ix SYP rafters spaced no more than 24"o.c. Slope Range: 3;12 or greater - without la sealant less than 3:12 - with lap sealant C •' ; `�•. .Jz 7r Sr X OF Ou 2`�' t Ai•.�.�P`re� 4A ..... } 1791 Blount Road unit 907 Pompano Beach - Florida - 33069 Tel: (754) 307-1319 Fax: (754) 205-$646 Email: Engco@AOL.com 5.5 Minimum Underlayment: Date: 8/1712017 REF.#: 1.7-29610 30# Asphalt saturated organic felt paper installed with a minimum 4" side lap and 6" end laps. Underlayment shall be fastened with corrosion resistant approved fasteners as per the Florida Building Code and spaced 6"oc at all laps and two staggered rows 6"oc in the field of the row. Or, any underlayment having a current product approval. 5.6 Minimum. Fire Barrier Board: VersaShield with a minimum 4" side Iap and 6" end laps. VersaShie►dshall be fastened with corrosion resistant approved fasteners as per the Florida Building Code spaced at 6"oc at the perimeter and overlaps aid two intermediate staggered spaced rows at 6"oc. Or, any approved fire barrier having a current Product Approval. See Limitations #11.2 5.7- Fasteners: Installed through Nail Strip Panel (Not Pre-existing slots): #10-94" Panclip MTW fasteners spaced at 6"oc 6.0 Product anchorage to Roof Deck: 6.1- Panels are to be secured through the nail st fasteners spaced at 6"oc. The fasteners are to be not the pre existing slots. The female leg of the f 7.0 Uplift Pressures Rating: UL 580 - Standard for Safety, Tests for Uplift Res ip leg of the panel using #10-9x1" Panclip MTW positioned to go through the nail strip panel and 3nei snap fit to the male leg of the panel. of Roof Assemblies Installation Design Pressure Safety Factor I Anchors Spacing Field 132 psf 2 6" oc Corner Extrapolation is not allowed F : c.:. No, 5254 -� STAB ��''• �C O JD�- t ec;,�'i 1791 Blount Road unit 907 Pompano Beach - Florida - 33069 Tel: (754) 307-1319 Fac (754) 205.6846 Email: Engco@AOL.com 8.0 Summary of Test Results: 8.1.4rchitectural Testing, Inc., West Palm Beach) FL. 8.2 Report G3443.08-450-44, dated 06/15/2017. 8.3 UL 580 . Standard for Safety, Tests for Uplift Res 8.4Test Specimens: 120" x 120" with 16" x 120" Ilpar 8.5 Testing Assembly 8.6 Report H68S4.01-106-31, dated 10/19/2017. Layer 1: 30# Asphalt saturated organicfelt paper install, Underlayment shall be fastened with corrosion Building Code and spaced 6"oc at all laps and t% underlayment having a current product approv Layer 2: VersaShield with a minimum 4" side lap and 6" corrosion resistant approved fasteners as per th perimeter and overlaps and two intermediate st barrier having a current Product Approval. See l Layer 3: 26 Gauge - 0.01875" thick x 16" Gavanized steel Panclip MTW fasteners spaced at 6"oc. The fast Field/comer panel and not the pre-existing slots. The female Installation adjacent panels 9.0 Installation Instructions: Panels to be installed as per manufacturer instru Date: 811712017 REF.#: 17-29610 of Roof Assemblies elcoverage with a minimum 4" side lap and 6" end laps. sistant approved fasteners as per the Florida staggered rows 6"oc in the field of the roll. Or, any d laps. VersaShield shall be fastened with Florida Building Code spaced at 6"oc at the ggered spaced rows at 6"oc. Or, any approved fire nitations #11.2 anels secured to the wood deck using #10-9 x 1" ners were positioned to go through the nail strip :g of the panel snap -fit to the male leg of the and fastening patterns described herein, •gay, �.: r, No.5260 v STME OCT 2 0 2017 E N G C 0, inc. 1791 Blount Road unit 907 Pompano Beach - Florida - 33069 Tel: (754) 307-1319 Fax; (754) 2( Email: Engoo@ADL.com 10.0 Design Procedure; 10.1- In order to verify product adequacy for; Design Rating on section 7 above with the Pro. chapter 16 requirements. 10.2 - Product Pressures Rating must be greats 10.3 - Supporting structure are to be designed 10.4 - Deck sheet must meet the minimum thi 11.0 Limitations and Conditions of Use: 11.1- installation must not exceed the maximu Neither rational analysis, nor extrapolation sha pressure zones (i.e. perimeter, extended corne 11.2 - Fire Classification is not part of this accep Directory for fire rating of this product. 11.3 - Product were not evaluated structurally i loads 11.4 - All Products listed herein shall have a qua Building Code Rule 61G20-3 of the Florida Adm 11.5 - Drawing numbered 17-296.10 dwg are pi 12.0 Certificate of Independence: Date: 811712D17 REF.#: 17-29610 specific project, contractor must compare Uplift :t Design Wind pressures calculated based on FBC than the Project Design Wind Pressures y others and in compliance with the FBC ness specified on item 5.4 above i allowable design pressures listed in this report. be permitted for enhanced fastening at enhanced and corners) ance; refer to a current Approved Roofing Material resist shear diaphragm, axial, transverse or racking ity assurance audit in accordance with the Florida listrative Code t integral of this report. TAS 125- 03 - Uplift Resistance Test - G3443.09-450-44 TAS 100- 95 - Wind Driven Rain Test - 1-12687.02 �450-44 ASTM G26%G 155 - Accelerated Weathering 2000 hours - PRI Report- VLS-004-02-01 ASTM B117 - Salt Spray Testing of Coating 1000 hours - PRI Report - VLS-005-02-01 13.0 Certification: In the professional opinion of this evaluating en requirements of the Florida Building Code 2017 (Broward and Miami -Dade counties) when utilb ineer the product herein described meets the 6th edition, for use in the NON-HVHZ and HVHZ d within the limits of use noted herein DRAWINGS #: 1 7-29G. 1, O REPORT : 1 7-29G. 10 r0. 52609 s b + DRAWINGS #: 1 7-29G. 10 REPORT: 1 7-29G- 10 # I � y. f DYNAMIC I ° NAIL5TRIP 2G GAUGE GALVANIZED- 5TEEL PANEL PANEL SPACED AT 6" OC FASTENER POS I T I LlNED THROUGH THE NAIL STRIP NOT THROUGH THE PRE-EXISTING SLOTS 1p cEAj 1W. 5260 STAI ; 1 ROOF DECK ti MINIMUM 1 5/32" `t--4-PLY CDX PLYWOOD SHEAT ING