Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutEVALUATION REPORTt _R14�Id�Y ERD
EVALUATION REPORT
Soprema, Inc.
1640 rue Haggerty
Drummondville, Qu6bec J2C 5P8 Canada
(819) 478-2400
St Luc BY
oe coup
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
f (203) 262-9245
Evaluation Report S18010.06.09-R11
FL2569-R13
Date of Issuance: 06/15/2009
Revision 11:10/06/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and t e applicable rules and regulations governing the use of
construction materials in the State of Florida. The documen ation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Cade and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compljance with the & Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions oft i e Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements -with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words `Trinity) ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DC4 ANE1983
CERWICAMON OF INDEPENDENCE:
I. TrinitylERD does not have, nor does it intend to acquire or will
distributing products it evaluates.
2. Trinity ERD is not owned, operated or controlled by any company r
3. Robert Nieminen, P.E. does not have nor will acquire, a financial it
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial i
product.
5. This is a buildingcode evaluation. Neither Trinityl ERD nor Robei
project on which this Evaluation Report, or previous versions there
ecifically for that p Jo e.
ST. LUCIE COUNTY BUILDING DIVISION
REVIEWED FOR COMPLIANCE
REVIEWED
DATE `
PLANS AND PERM T MUST BE KEP. ON 309
SITE OR NO INSPECTIONS) WILL BE MADE
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
G COMPLY WITH ALL APPLICABLE CODES.
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10106/2017. This does not serve as an
electronically signed document
acquire, a financial interest in any company manufacturing or
cturing or distributing products it evaluates.
in any company manufacturing or distributing products for
in any other entity involved in the approval process of the
Nieminen, P.E. are, in any way, the Designer of Record for any
if, is/was used for permitting or design guidance unless retained
CONGSALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OR RECORD
ROOFING COMPONENT EVALUATION:
I. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment .
Compliance Statement: Roof Underlayments, as pi
following sections of the 6u' Edition (2017) Florida E
Standards. Compliance is subject to the Installatioi
herein.
2. STANDARDS:
Section
1504.3.1
1504.3.1
1507.1.1, T1507.1.1,1507.2.9.2
1507.3.3
FRSA/TRIApril 2012(04-12)
TAS 110
3. REFERENCES:
Entity
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
M-D (CER1592)
ICC-ES (EVL2396)
PRI(TST5878)
Soprema, Inc (PDM3511)
UL, LLC (QUA9625)
4. PRODUCT DESCRIPTION:
Property
Wind Resistance
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
Accelerated Weath
Examination
ASTM D1970 / TAS 110
Physical Properties
ASTM D1970 / TAS 110
Wind Resistance
Wind Resistance
TAS 103 / TAS 110
ASTM D1970 / TAS 110
ASTM D1970 / TAS 110
Physical Properties / Ter
Physical Properties / Ter
ASTM D1970 I
ASTM D1970
Physical Properties / Ter
Physical Properties/Ter
Accelerated Weathering
Wind Resistance
HVHZ Compliance
2015 IBC Compliance
Physical Properties
Equivalency Declaration
Quality Control
4.1 Lastobond TU HT is a self -adhering,
underlayment; meets ASTM D1970 and
TRINITY I ERD
duced by Soprema, have demonstrated compliance with the
ilding Code through testing in accordance with the following
Requirements and Limitations / Conditions of Use set forth
Standard
FM 4474
UL 1897
ASTM D1970
FRSA/TRI April 2012
ASTM D6163
TAS 110
Reference
2968.05.04-2
2757.02.05
2974.03.05-2
2778.07.05
2779.11.05-111
S7120.11.07-2
S13190.02.09-R1
S31370.03.10-1-R1
Adhesion
S11150.05.10-R1
Adhesion
S11150.05.09-112
S37210.11.11
S40540.02.13-1
Adhesion
S43530.02.14-1
Adhesion
SOPC-SC7645.02.15
SOPC-SC8520.14
SOPC SC14045.05.17-R1
15-0508.04
ESR-1524
SOP-064-02-01
SA SMOOTH PLY 40
Service Confirmation
Year
2011
2012
2015
2012
2008
2000
Date
05/14/2004
02/03/2005
05/17/2005
07/15/2005
04/18/2007
11/02/2007
04/01/2010
04/07/2010
09/09/2010
10/05/2010
11/09/2011
02/19/2013
02/21/2014
02/13/2015
04/17/2015
06/07/2017
09/24/2015
03/01/2017
12/03/2013
06/29/2015
Exp.07118/2020
n polyester fabric surfaced, SBS modified bitumen roof
April 2012 (04-12).
4.2 Lastobond Shield is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths; 36 and 45 inch; meets ASTM D1970.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adl
underlayment; available in 3.3 ft x 65 ft ro
4.4 Lastobond Shield HT is a self -adhering,
bitumen roof underlayment; meets ASTM
ng, woven polyethylene surfaced, SBS modified bitumen roof
meets ASTM D1970.
ven polyethylene surfaced, high temperature, SBS modified
Exterior Research and Design, LLC Evaluation Report S18010.06.09-Rll
CalifealeOfAutharfmtion#9503 6'"EDITION (2017)FBCNON-HVHZEVALUATION FL2569-R33
Sop Tema, Inc. Revision =10/06/2017
Paee 2 of 8
4.5 Lastobond Pro HT N is a self -adhering, m
underlayment available in two widths; 36 and
4.6 Lastobond Pro HT S is a self -adhering, wov
bitumen roof underlayment; meets ASTM DIE
4.7 Lastobond 195 is a self -adhering, glass-m;
underlayment; meets ASTM D1970.
4.8 Lastobond Eaves Protection Sheet is a self
bitumen roof underlayment; meets ASTM D19
4.9 Lastobond Eco is a self -adhering, glass-mi
�"---underlayment, meets ASTM D1970.
4.11 RESISTO LBV36 is a self -adhering, glass-mz
underlayment, with a 36-inch sheet width; mee
4.12 PrimeSource Grip -Rite Eave & Valley Protecto
modified bitumen roof underlayment, with a 3(
4.13 RESISTO L81244 is a self -adhering, glass -ma
underlayment, with a 44-inch sheet width; mee
m polyethylene surfaced, SBS modified bitumen roof
inch; meets ASTM D1970.
polyethylene surfaced, high -temperature, SBS modified
reinforced, sand -surfaced, SBS modified bitumen roof
glass -mat reinforced, sand -surfaced, SBS modified
reinforced, sand -surfaced, SBS modified bitumen roof
reinforced, sand -surfaced, SBS modified bitumen or of
s ASTM D1970.
is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
inch sheet width; meets ASTM D1970.
reinforced, sand -surfaced, SBS modified bitumen roof
s ASTM D1970.
4.14 Colphene FIR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrTity1ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance'unless retained specifically forthat purpose.
5.2 This Evaluation Report is not for use in FBC HVHZa jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.5 Allowable Roof Covers:
Underlayment
Asphalt
Nai(On
Foam -On
Metal
Wood Shakes &
Slate
Shingles
Tile
Tile
Shingles
Lastobond TU HT
Yes-"
Yes"
Yes
%Yes
::. Yes
Yes
Lastobond Shield / Pro HT-N / RES1 FO SA
Yes
SMOOTH PLY 40
•
ryYa� Now*�
tNooz
t
Yes
Yes
Lastobond Shield HT/ Pro HT-S
Yesrnfop,wsxl
Yes
Yes
Yes
Lastobond Eaves Protection Sheet
Lastobond 195
Yes,
Lastobond ECO / RESISTO LB1236,,Grip-
Rite Eave & Valley Protector / RESISTO
Yes
; No
7Wt
w; sT�jo
N
Yes
Yes
F
ti
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
e EDITION (2017) FBC NON-HVHZ EVALUATION
Soprema, Inc
Evaluation Report S18010.06.09-R11
-'� FL2569-R13
Revision 11:10/06/2017
Page 3 of S
St{iq !
1 d
V
o TRINITY ERD
TAel.E1 RaoFGovarOPzroNs
�' � � � "`
Underlayment
Asphalt
ail -On
Foam -On
Metal
Wood Shakes &
Slate
Shingles
Tile
Tile
>
Shingles
Lastobond Smooth Seal HT
Yes
Yes
Colphene FR GR
Yes
f
Yes
veso'
Yes
Yes
See SS:1
: t�.u-'"
5.5.1 "Foam -On Tile" is limited to use of following Approved file adhesives / underlayment combinations.
Au?owas>Til�Ane
Ivl %UNnF�tu►vnnEn[rCpmemu►noNs�^� _% ��;
Adhesive
Florida ProductAPpr
l
Underlayments
DowTileBond"
FL22525 I
Lastobond TU HT
ICP Adhesives Polyset° AN-160
FL6332
Lastobond TU HT or Colphene FR GR
5.6
5.6.1
5.6.2
Allowable Substrates:
Direct -Bond to Deck:
Lastobond Shield, Lastobond Pro HT N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Protector, REIISTO LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine, ASTM D41
primed Southern Yellow'Pine; ASTM D41 primed structural concrete.
Colphene FR GR applied to:
➢ Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 60I0c if the final roof cover is not slated for installation within
24 hours.
➢ Soprema requires tongue -and -groove bI
installation of the self -adhering underlaym
Bond -to -Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISI
Pro HT S, Lastobond TU HT, Lastobond Eaves P
LB1236, Grip -Rite Eave & Valley Protector, RE
GR applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber
For installation under mechanically attached F
minimum requirements of the prepared roof co
under foam -on file systems (Lastobond TU HT o
design professional and installed based on test
with FM 4474, Appendix D, Testing Application
1 Refer to Tile Manufacturer's orAdbesive Manufacturers Florida
Exterior Research and Design, LLC.
CuVflwte of Authomaton A9503 EDITION (2017) FBC NOI
Soprema,
decking be covered with plywood or OSB prior to
SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
ection Sheet, Lastobond 195, Lastobond ECO, RESISTO
'O LB1244, Lastobond Smooth Seal HT or Colphene FR
toof Board.
-epared roof coverings, insulation shall be attached per
rering manufacturer's Product Approval. For installations
dy), insulation attachment shall be designed by a qualified
ng of the insulation/underlayment system in accordance
standard TAS 114, Appendix J or UL1807.
Approval for Overturning Moment Resistance Performance.
Evaluation Report S18010.05.09-R31
EVALUATION FL2569-R13
Revision 11:10/06/2017
Page 4 of 8
5.6.3
Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESI
HT-S, Lastobond TU HT, Lastobond Eaves Pr,
LB1236, Grip -Rite Eave & Valley Protector, RES
applied to:
➢ ASTM D226, Type I or 11 felt; Sopra-G; Mod]
7
\,ITRINI Y € ER©
SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
ection Sheet, Lastobond 195 Lastobond ECO, RESISTO
-0 LB1244, Lastobond Smooth Seal HT or Colphene FR GR
Sopra-G.
zz)f coverings; base layer shall be attached per
_:. _..... `}ons under foam -on tile systems (Lastobond TU HT only),
base :cycr:;hz 11 'a =.achcd ;r, axar_'srca Ith rSA/Tgl April 2012 (04-12).
5.6.4 Wind Resistance for Underlayment Svstems ink F
does not address wind uplift resistance of all ui1c
the underlayment forms part of the load -path. TI
systems that are not addressed in FRSA/TRI Apri
Maximum Design Pressure is the result of testing
and reflects the ultimate passing pressure divide
already been applied). Refer to FRSA/TRI April 2(
pressures.
#1 Maximum Design Pressure = -45.0 psf:
)am -On Tile Applications: FRSA/TRI April 2012 (04-12)
erlayment systems beneath foam -on tile systems, where
e following wind uplift limitations apply to underlayment
12012 (04-12) and are used in foam -on the applications.
for wind load resistance based on allowable wind loads,
d by.2 (the 2 to 1 margin of safety per FBC 1504.9 has
12 (04-12) or FBC 1609 for determination of design wind
Deck: Min. 15/32-inch plywood to (meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
::2 Design Pressure = -67.5 psf:
Deck: Structural concrete to meet p oject requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol600L
Underlayment: Lastobond TU HT or Colp:`:"c_ F,; CE., SCIi-8uiicrEd.
#3 Maximum Design Pressure = -150.0 psf:
- L k: -...... -..: ^.?^.. atcd 3C
requirements to satisfaction of A
Deck Preparation: Plywood shall be thoroughly cl
adhesion. All sheathing fasten
splinters and wood projections s�
Primer: (Optional) RESISTO EXTERIOR PR,l
Underlayment: Lastobond TU HT, self -adhered,
weighted roller to ensure there
side and end -laps.
#4 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to me
Having Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G me
caps (FBC 1517.5.2) spaced 6-inc
equally spaced rows in the center
Underlayment: Lastobond TU HT or Colphene FR i
5.6.4.1 All other direct -deck, adhered Soprema underlayr
Maximum Design Pressure of-45 psf.
plywood (may be installed C-side up) to meet project
uthority Having Jurisdiction.
eaned to remove dust and debris that may inhibit
hers shall be d�ivcr; `u--l' . _ , su "ace. Ali sharp
all be removed/sanded.
Exterior Research and Design, LLC.
Certyiage of AathonzaBon #9503 6T" EDITION (2017) FBC NON-HVHZ
Soprema, Inc
shall be thoroughly roll using hand roller and/or
no voids, and ensure there are no voids/bridging at
project requirements to satisfaction of Authority
ianically attached with nails (FBC 1517.5.1) and tin
o.c. at the 4-inch laps and 6-inch o.c. in three (3),
the sheet.
, self -adhered
nt systems beneath foam -on the systems carry a
Evaluation Report S18010.06.09-R11
FL2569-R13
Revision 11:10/06/2017
Page 5 of 8
5.6A.2
5.7
5.8
i �•� f
"' TRINITY I ERD
For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012.(04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI 1 1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk*,carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobon 1195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO
LB1236, Grip -Rite Eave & Valley Protector or IESISTO LB1244 shall not be left exposed for longer than 30-
days after installation-
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
When loading roof tiles on the underlayment in direct -deck file assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE2 TItESCIPPQGELIMITAT10N5•FORDIRECrDEC[CTICE(NSTAW1710N5
" . ,. v._ • ,,.-,
tnderlayment
Tile Profile
staging Method
Maximum
Slope
Flat
Max.10-tile stack
6-12
Lugged
Max.10-tile stack
5:12
Max.10-tile stack (bottom 2-tile stack
'shall be inverted, followed by 8 tiles high
6:12
on slope, as shown below)
Lastobond TU HT
Lugged
•
=_
.m
Flat
Max.10-tile stack
5:12
Colphene FR GR
Lugged
Max.10-tile stack
612
Exterior Research and Design, LLC.
Certifcare of Autharizaoon #9503 67 EDITION (2017) FBC
Evaluation Report 518010.06.09-R31
V-HVHZ EVALUATION FL2569-R13
Inc Revision =10/06/2017
Page 6 of 8
it
1
i
i
�! TRlNITY"ERD
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check IIfor protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol
600c or RESISTO EXTERIOR PRIMER (if applicable).
6 3 �LastotiondtTU-7i�', Lasto6ond SKleld�tastobondPro�X-fU� RESIS`CCI-SASMOO'CH PL1G 4Q I�stohond 5CileTd;
rl� Lastobond Pro .>4iT S, T:asbobond Eaves Protection Sheet,.LastoboncT.�.95,1astobond l=co, Lastafiond.
___Smooth�eaT.T�T,ti~ESISrT��.B1336, Gnp Rtte�a�te`&_ VallexProtector, RESIS.fdtB1243,orC_olpfieneFRGR
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile Applications:
While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO
EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps
shall be sealed using either heat -welding or hot air welding techniques.
When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of
the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into !place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (0412) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on file applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner) that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and Soprema published requirements for tile staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Exterior Research and Design, LLC_
eerhfiaQDe ofAurhonwbron #9503
I
i
I
6T" EDITION (2017) FBC NON-HVHZIEVALUATION
Soprema, Inc
Evaluation Report S18010.06.09-R11
FL2569-R13
Revision 11:10/06/2017
Page 7 of 8
""jTRINTYIERD
B. MANUFACTURING PLANTS:
Contact the noted CtA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical properties specifications.I
10
Lastobond Shield RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Drummondville,
Pro Lastobond Pro HT-5, Lastobond 195, Lastobond
QC (Canada)
ASTM D1970Lastabond
Eavel s Protection Sheet, Lastoborid Eco, Lastobond Smooth Seal HT,
RESISTO LBIZ6, PrimeSource Grip -Rite Eave & Valley Protector,
RES 1 0 LB1244
ASTM D1970 & FRSAITRI 04-12
Wphene FR GR
Wadsworth, OH
Last6bond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
ASTM D1970
I
Lastobond Smooth Seal HT, RESISTO L81236, PrimeSource
Grip -Rite
Eav� & Valley Protector, RESISTO LB1244
ASTM D1970 & FRSA/TRl 04-12
Last6bond TU HT; Colphene FR GR
Gulfport, MS
Last6bond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
ASTM D1970
I
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip
I
-Rite
Eavej& Valley Protector, RESISTO LB1244
QuAmyAssLIRANCE ENTITY:
UL, LLC — QUA9625; (314) 578-3406; k.chance11orCq)Us.Ul
-Exterior Research and Design, LLC
CatiTICOW OfAuthorimdon #9503
-END OF EVALUATION REPORT -
EDITION (2017) FBC -,,,,VHZ EVALUATION
Soprerna, In"I
Evaluation Report S18010.06.09-1111
FL2569-1113
Revision 11. 10/06/2017
Page 8 of 8