Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED FORM R405-2017 St Luc iBy FLORIDA ENERGY EFFICI� Ce 8 CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: OS 35 Murphy Builder Name: Street: Waldo Pepper Dr Permit Office: St Lucie City, State, Zip: Port St. Lucie , FL, 34987 Permit Number: Owner: OS 35 Murphy Jurisdiction: Design Location: FL, VERO_BEACH_MUNICIPAL_ARPT County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2420.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2121.90 ft2 b. Frame - Wood, Adjacent R=11.0 298.67 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2532.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20..0 2532.00 ft2 6. Conditioned floor area above grade (W) 2532 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(471.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 200 a. U-Factor: Dbl, U=0.62 319.50 ft2 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.51 96.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.22 a. Central Unit 42.0 SEER:16.00 c. U-Factor: Dbl, U=0.25 32.00 ft2 SHGC: SHGC=0.18 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 23.89 ft2 a. Electric Strip Heat 29.7 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.240 14. Hot water systems 8. Floor Types (2532.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2532.00 ft2 b. Conservation features EF: 0.950 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 71.80 Glass/Floor Area: 0.186 PASS Total Baseline Loads: 82.23 i I hereby certify that the plans and specifications covered by Review of the plans and ST,q?� this calculation are in compliance with the Florida Energy specifications covered by this OF'TKE Code. calculation indicates compliancer�„�'''� _ D with the Florida Energy Code. PREPARED BY: Before construction is completed u� DATE: 1i26118 this building will be inspected for compliance with Section 553.908* I hereby certify tha is ' ding s designe is in compliance Florida Statutes. with the Florida E ergy Cod COD WE�v OWNER/AGENT: BUILDING OFFICIAL: DATE: 0 '� DATE: - Compliance requires certifi ation by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 4.50 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requiresi a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. FILE COPY 1/26/2018 3:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: OS 35 Murphy Bedrooms: 3 User Conditioned Area: 2532 OS 35 Murphy Total Stbries: 1 1 Worst Case: No Rotate Angle: 0 St Lucie Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) iI Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address Waldo Pepper Dr St. Lucie Port St. Lucie , FL, 34987 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, VERO_BEACH_MUN FL_VERO_BEACH_MUNI 45 90 70 75 299 64 Medium BLOCKS Number Name Area Volume 1 Block1 2532 23547.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2532 23547.6 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 219'.2 ft 0 i 2532 ft2 ---- 1 0 0 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Composition shingles 2832 ft2 0 ft2 Medium 0.9 N 0.9 No 20 26.6 ATTIC v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2532 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 20 Blown 2532 ft2 0.1 Wood 1/26/2018 3:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 WALLS Adjacent I Cavity Width Height Sheathing Framing Solar Below Ora+ To -Wall -Type Space -R-Value Ft In _ FtInArea R,/alue-F-raction-Absor-Grade%- 1 N Exterior Concrete Block - Ext Insul Main 4.1 54 4 9 0 489.0 ft2 0 0 0.8 0 2 NE Exterior Concrete Block - Ext Insul Main 4.1 3 7. 9 4 33.4 ft2 0 0 0.8 0 3 E Exterior Concrete Block - Ext Insul Main 4.1 36 1 9 4 336.8 ft2 0 0 0.8 0 4 SE Exterior Concrete Block - Ext Insul Main 4.1 3 7 11 5 40.9 ft2 0 0 0.8 0 5 S Exterior Concrete Block - Ext Insul Main 4.1 62 8 9 0 564.0 ft2 0 0 0.8 0 6 SW Exterior Concrete Block - Ext Insul Main 4.1 5 10 9 0 52.5 ft2 0 0 0.8 0 7 W Exterior Concrete Block - Ext Insul Main 4.1 61 5 9 0 552.8 ft2 0 0 0.8 0 T 8 NW Exterior Concrete Block - Ext Insul Main 4.1 5 10 9 0 52.5 ft2 0 0 0.8 0 9 - Garage Frame - Wood Main 11 32 0 9 4 298.7 ft2 0 0.25 0.8 0 DOORS I # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood Main None .39 6 8 48 ft2 2 - Wood Main I None .39 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall i Overhang V # Ornt ID Frame ' Panes NFRC. U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Low-E Double Yes 0.25 0.18 N 12.0 ft2 1 ft 0 in 1 ft 0 in None None 2 n 1 Metal Low-E Double Yes 0.62 0.25 N 12.0 ft2 1 ft 0 in 1 ft 0 in None None 3 n 1 Metal Low-E Double Yes 0.62 0.25 N 12.3 ft2 1 ft 0 in 1 ft 0 in None None 4 n 1 Metal Low-E Double Yes 0.62 0.25 N 19.6 ft2 1 ft 0 in 1 ft 0 in None None 5 n 1 Metal Low-E Double Yes 0.62 0.25 N 20.0 ft2 1 ft 0 in 1 ft 0 in None None 6 e 3 Metal Low-E Double Yes 0.62 0.25 N 36.0 ft2 1 ft 0 in 1 ft 0 in None None 7 e 3 Metal Low-E Double Yes 0.62 0.25 N 24.0 ft2 1 ft 0 in 1 ft 0 in None None 8 e 3 Metal Low-E Double Yes 0.4 0.26 N 8.0 ft2 1 ft 0 in 1 ft 0 in None None 9 se 4 Metal Low-E Double Yes 0.62 0.25 N 11.5 ft2 1 ft 0 in 1 ft 0 in None None 10 S 5 Metal Low-E Double Yes 0.62 0.25 N 24.0 ft2 1 ft 0 in 1 ft 0 in None None 11 s 5 Metal Low-E Double Yes 10.62 0.25 N 12.0 ft2 1 ft 0 in 1 ft 0 in None None 12 s 5 Metal Low-E Double Yes 10.62 0.25 N 30.0 ft2 1 ft 0 in 1 ft 0 in None None 13 sw 6 Metal Low-E Double Yes 0.62 0.25 N 20.8 ft2 1 ft 0 in 1 ft 0 in None None 14 w 7 Metal Low-E Double Yes 0.25 0.18 N 20.0 ft2 1 ft 0 in 1 ft 0 in None None 15 W 7 Metal Low-E Double Yes 0.62 0.25 N 30.0 ft2 1 ft 0 in 1 ft 0 in None None 16 W 7 Metal Low-E Double Yes 0.62 0.25 N 36.0 ft2 1 ft 0 in 1 ft 0 in None None 17 W 7 Metal Low-E Double Yes 0.51 0.22 N 96.0 ft2 1 ft 0 in 1 ft 0 in None None 18 W 7 Metal Low-E Double Yes 0.4 0.26 N 15.9 ft2 1 ft 0 in 1 ft 0 in None None 19 w 7 Metal Low-E Double Yes 0.62 0.25 N 8.0 ft2 1 ft 0 in 1 ft 0 in None None 20 nw 8 Metal Low-E Double Yes 0.62 0.25 N 9.2 ft2 1 ft 0 in 1 ft 0 in None None 21 NW 8 Metal Low-E Double Yes 0.62 0.25 N 14.2 ft2 1 ft 0 in 1 ft 0 in None None 1/26/2018 3:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 504 ft2 504 ft2 64 ft 9.3 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000266 1766.1 96.95 182.34 .1994 4.5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 29.72 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 42 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60 gal 120 deg None SOLARi HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # -- Supply ---- Location R-Value Area ---- Return --- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 100 ft2 Prop. Leak Free Main --- cfm 76.0 cfm 0.03 0.50 1 1 1/26/2018 3:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 TEMPERATURES Programablre Y Ceiling Fans: �Thermostat:H Jan Coo Heating H Jan Feb Feb � Mar Apr a,X IJun XI Ju Aug �Xj ri Sep Oct Oct Nov Nov H Dec Dec H Venting [[[ ]]] Jan Feb X Mar Apr May JJun un Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78. Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1/26/2018 3:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index, the more efficient the home. Waldo Pepper Dr, Port St. Lucie, FL, 34987 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Dbl, U=0.62 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.51 SHGC: SHGC=0.22 c. U-Factor: Dbl, U=0.25 SHGC: SHGC=0.18 d. U-Factor: other (see details) SHGC: other (see details) New (From Plans) 9. Wall Types Single-family a. Concrete Block - Ext Insul, Exterior b. Frame - Wood, Adjacent 1 c. N/A 3 d. N/A 10. Ceiling Types No a. Roof Deck (Unvented) 2532 b. N/A Area c. N/A 318.50 ft2, 11. Ducts a. Sup: Attic, Ret: Attic, AH: Main 96.00 ft2 12. Cooling systems 32.00 ft2 a. Central Unit 23.89 ft2 Area Weighted Average Overhang Depth: 1.000 ft., Area Weighted Average SHGC: 0.240 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2532.00 ft2 b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied Construction through the above ene in this home before final inspection. based on installed Code compliant f Builder Signature: Address of New Home: r 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits M the Florida Energy Efficiency Code for Building saving features which will be installed (or exceeded) ierwise, a new EPL Display Card will be completed Date: City/FL Zip: Insulation Area R=4.1 2121.90f12 R=11.0 298.67 ft2 R= ft2 R= ft2 Insulation Area R=20.0 2532.00 f12 R= ft2 R= ft2 R ft2 6 200 kBtu/hr Efficiency 42.0 SEER:16.00 kBtu/hr Efficiency 29.7 COP:1.00 Cap: 50 gallons EF: 0.95 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you,obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/26/2018 3:45 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 - - Wr`ightso►ftp Project Summary Entire House Project Information For: OS 35 Murphy Waldo Pepper Dr, Port St. Lucie, FI 34987 Notes: Weather: Winter Design Conditions Outside db Inside db Design TD 43 'F 70 °F 27 °F Heating Summary Structure 27088 Btuh Ducts 2635 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 0 Btuh 0 Btuh 29723 Btuh Vero Beach Muni, FL, US Simplified Average 0 Heating Cooling Area (ft') 2532 2532 Volume (ft') 25787 25787 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 138 69 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.7 kW 29723 Btuh 19 °F 1400 cfm 0.047 cfm/Btuh 0.53 in H2O Job: OS 35 Murphy Date: Jan 24, 2018 By: Roger Harris Summer Design Conditions Outside db 91 °F Inside db 75 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Sensible Cooling Equipment Load Sizing Structure 28899 Btuh Ducts 1936 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 29447 Btuh Latent Cooling Equipment Load Sizing Structure 3573 Btuh Ducts 584 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 4157 Btuh Equipment Total Load (Sen+Lat) 33604 Btuh Req. total capacity at 0.80 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond CA16NA0420000A0 Coil FX4DNF049L AHRI ref 9199824 Efficiency 13.0 EER, 16 SEER Sensible cooling 33600 Btuh Latent cooling 8400 Btuh Total cooling 42000 Btuh Actual air flow 1400 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.53 in H2O Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -' !'- wrlghtsoft- 2018-Jan-26 15:36:13 «., ...d. Right -Suite® Universal2018 18.0.04 RSU11033 Page 1 ACCk ers Work\Outgoing\OS 35 Murphy\OS 35 Murphy.rup Calc = MJ8 Front Door faces: E Duct Layout Job #: OS 35 Murphy Performed by Roger Harris for: OS 35 Murphy Waldo Pepper Dr Port St. Lucie, FI 34987 Scale: 1 : 117 Page 1 Right -Suite® Universal 2018 18.0.04 RSU11033 2018-Jan-26 15:36:69 ...ng\OS 35 Murphy\OS 35 Murphy.rup + - wrightsoft° Duct System Summary Entire House Project I• • For: OS 35 Murphy Waldo Pepper Dr, Port St. Lucie, FI 34987 External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) meaning 0.53 in H2O 0 in H2O 0.53 in H2O 0:341 / 0.189 in H2O 0.233 in/100ft 1400 cfm 227 ft Job: OS 35 Murphy Date: Jan 24, 2018 By: Roger Harris cooung 0.53 in H2O 0 in H2O 0.53 in H2O 0.341 / 0.189 in H2O 0.233 in/100ft 1400 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath 2 h 986 46 27 0.308 4.0 Ox 0 VIFx 20.9 90.0 st4 Bath 3 h 1833 86 37 0.237 6.0 Ox 0 VIFx 44.3 100.0 sty Bed 2 h 1859 88 63 0.311 6.0 Ox 0 VIFx 19.7 90.0 st4 Bed 3 h 1604 76 53 0.243 6.0 Ox 0 VIFx 40.6 100.0 st5 Den h 3224 152 92 0.270 7.0 Ox 0 VIFx 36.5 90.0 st3 Dining C 2258 99 103 0.320 6.0 Ox 0 VIFx 16.8 90.0 st4 Foyer h 1533 72 56 0.271 5.0 Ox 0 VIFx 35.9 90.0 st3 Great Rm C 3885 102 176 0.264 8.0 Ox 0 VIFx 39.5 90.0 st3 Great Rm-A c 3885 102 176 0.233 8.0 Ox 0 VIFx 46.2 100.0 st5 Hers C 93 2 4 0.254 4.0 Ox 0 VIFx 44.4 90.0 st2 His h 855 40 17 0.245 4.0 Ox 0 VIFx 49.1 90.0 st2 Kitchen C 2405 13 109 0.245 6.0 Ox 0 VIFx 39.4 100.0 st5 M Toilet h 380 18 7 0.267 4.0 Ox 0 VIFx 37.9 90.0 st3 Master Bath h 1101 52 30 0.284 5.0 Ox 0 VIFx 30.3 90.0 st3 Master suite h 2831 133 105 0.240 7.0 Ox 0 VIFx 52.4 90.0 st2 Master suite -A h 2831 133 105 0.249 7.0 Ox 0 VIFX 47.0 90.0 st2 Mach h 416 20 12 0.467 4.0 Ox 0 VIFx 3.2 70.0 Nook C 4251 155 193 0.252 8.0 Ox 0 VIFx 35.5 100.0 St5 utility c 761 11 35 0.340 4.0 Ox 0 VIFx 10.3 90.0 st4 41-1- wu►riightsoft" �^ �,...�,......,�,.,.., Rig htSuite®Universal 2018 18.0.04 RSU11033 / + ...era Work\Outgoing\OS 35 Murphy\OS 35 Murphy.rup Cale = MJ8 Front Door faces: E 2018.Jan-26 15:36:13 Page 1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st5 Peak AVF 432 568 0.233 532 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 432 568 0.233 532 14.0 0 x 0 VinlFlx st2 Peak AVF 309 232 0.240 567 10.0 0 x 0 VinlFlx st3 Peak AVF 396 362 0.264 504 12.0 0 x 0 VinlFlx st4 Peak AVF 244 226 0.308 552 9.0 0 x 0 VinlFlx Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox0 858 1015 42.0 10.449 575 18.0 Ox '0 VIFx rb2 Ox 0 379 269 68.9 0.274 483 12.0 Ox 0 VIFx rb3 Ox 0 88 - 63 78.4 0.241 446 6.0 Ox 0 VIFx rt1 rb4 Ox 0 76 53 80.8 0.233 385 6.0 Ox 0 VIFx rt1 Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt1 Peak AVF 163 116 0.233 467 8.0 0 x 0 VinlFlx t -- wrightsoft^ 2018Jan-Jan15:36:13 Right Suite®Universal 2018 18.0.04 RSU11033 Page 2 'Ca ...ers Work\Outgoing\OS 35 Murphy\OS 35 Murphy.rup Calc = MJ8 Front Door faces: E