HomeMy WebLinkAboutEXTERIOR & INTERIOR ELEVATIONSS T R U C T U R R L N O T E S= CODES & STANDARDS WIND LOADS AS PER STANDARD BUILDING CODE 1994 EDITION THE PROJECT WAS DESIGNED IN ACCORDANCE WITH THE STANDARD BUILDING CODE 1994 EDITION BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (AGI 31BILATEST EDITION) MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (AGI 315/LATEST EDITION) MANUAL OF STANDARD PRACTICE FOR WELDING REINFORCING STEEL, INSERTS & CONNECTIONS IN REINFORCED CONCRETE CONSTRUCTION (AWS D1NLATEST EDITION) SPECIFICATION FOR THE DESIGN FABRICATION & ERECTION OF STRUCTURAL STEEL FOR BUILDINGS AMERICAN INSTITUTE OF STEEL CONSTRUCTION) AISC ASDVLATEST EDITION SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 3011LATEST EDITION) NATIONAL DESIGN SPECIFICATION, WOOD CONSTRUCTION NFPA/LATEST EDITION BUILDING CODE REQUIREMENTS AND SPECIFICATIONS FOR MASONRY STRUCTURES (AGI 530, 630.VASCE U /LATEST EDITIONS) DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK SECTIONS & DETAILS: ALL DETAILS, SECTIONS AND NOTES SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR SITUATIONS ELSEWHERE UNLESS OTHERWISE SHOWN 2. FOUNDATION BOTTOM OF FOOTINGS ASSUMED TO BEAR ON SOIL CAPABLE OF SAFELY SUPPORTING 26M PSF TOP OF ALL EXTERIOR FOOTINGS SHALL BE A MINIMUM 1 FOOT BELOW EXTERIOR FINISH GRADE CENTERLINE OF FOOTINGS: SHALL COINCIDE WITH CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED ON DRAWINGS 3. CONCRETE ALL CONCRETE SHALL BE READY -MIX, HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI 0 28 DAYS AND RAVE A MINIMUM OF 517 LBS. OF CEMENT PER CUBIC YARD SLUMPS SHALL BE 2' MINIMUM AND & MAXIMUM CONCRETE SHALL HAVE 4% AIR ENTRAINMENT (+/- 1%) ALL CONCRETE WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE ACI BUILDING CODE (ACI 31EVLATEST EDITION), THE ACI DETAILING MANUAL ((ACI 3161LATEST EDITION), AND THE SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 30VLATEST EDITION) CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS REQUIRED BY THE LATEST ACI SPECIFICATIONS WELDED WIRE FABRIC: SHALL COMPLY WITH ASTM A 186, UNLESS OTHERWISE SPECIFIED. PLACE FABRIC 2' CLEAR FROM TOP OF THE SLAB IN SLAB ON GRADE AND SUPPORT ON SLAB BOLSTERS SPACED AT T-0' O.C. ALL REINFORCING STEEL SHALL BE MANUFACTURED FROM HIGH STRENGTH BILLET STEEL CONFORMING TO ASTM DESIGNATION A 615, GRADE 80. WWF SHALL COMPLY WITH ASTM A 185 LAP ALL EARS MINIMUM 40 BAR DIAMETERS UNLESS OTHERWISE NOTED ON DRAWINGS. LAP ALL WWF A MINIMUM OF 6 INCHES (UNLESS OTHERWISE NOTED) REINFORCING BARS: AT OUTSIDE FACE OF CORNERS OF CONCRETE WALLS, BEAMS, AND CONT. WALL FOOTINGS, PROVIDE 1 15 x 4'-T BENT BAR FOR EACH HORIZONTAL BAR SCHEDULED AT THAT FACE. ALL HOOKS SHOWN IN REINFORCEMENT SHALL BE ACI RECOMMENDED HOOKS UNLESS OTHERWISE NOTED. CONSTRUCTION JOINTS IN STRUCTURAL SLABS AND BEAMS SHALL BE AT MID -SPAN AND KEY JOINTED WITH REINFORCING CONTINUOUS ACROSS JOINT, AND ADDITIONAL SHEAR FRICTION REINFORCING. CONCRETE LINTELS: DROP BOTTOM OF BEAM AT WINDOWS, DOORS AND MASONRY OPENINGS AS REQUIRED TO PROVIDE A CONCRETE CLOSURE BETWEEN THE BOTTOM OF THE BEAM AND WINDOW ANDYOR DOOR HE/4)ER. MAXIMUM DROP SHALL BE 18' (TWO BLOCK COURSES) AND SPAN EQUAL TO MASONRY OPENING WIDTH. PROVIDE 2 15 BARS AT BOTTOM OF DROP INCLUDING K3 TYPE S 6 TIES 0 24' OC. EXTENDING TO TOP OF BEAM REINFORCING. IF THE LINTEL EXCEEDS THE ABOVE LIMIT OF DROP, A SEPARATED LINTEL SHALL BE PROVIDED AS FOLLOWS: L1: OPENING LESS THAN 64 WIDE - T x 8' W/2a5 BOTTOM BARS L2: OPENING BETWEEN B'-T AND 12'-0' WIDE - 8' x 12' W12a8 BOTTOM BARS LINTELS TO HAVE 8' MINIMUM BEARING AT EACH END IF THE MASONRY OPENING HAS AN END ADJACENT TO A CONCRETE COLUMN, PROVIDE TWO 15 OR 18 DOWELS, AS THE CASE MAY BE, IN THE CONCRETE COLUMN WITH SHEAR KEY 1 V2' DEEP BY UNTE6•S DEPTH AND WIDTH FOR ITS SUBSEQUENT CONSTRUCTION 4. STEEL ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST AISC CODE STRUCTURAL STEEL SHALL CONFORM TO ASTM SPECIFICATION A36. ALL STEEL TUBING SHALL CONFORM TO ASTM SPECIFICATION A500, GRADE B. ALL STEEL PIPE SHALL CONFORM TO ASTM SPECIFICATION A501 ALL STEEL TO HAVE A SHOP COAT OF RUST INHIBITIVE PAINT ALL SHOP AND FIELD WELDING SHALL BE PERFROMED BY WELDERS QUALIFIED, AS DESCR18M IN 'AMERICAN WELDING SOCIETY'S STANDARD QUALIFICATION PROCEDURE' (AWS D1.1), TO PERFROM THE TYPE OF WORK REQUIRED. ALL ALUMINUM AND STEEL MEMBERS TO BE TREATED OR PROPERLY SEPARATED TO PREVENT GALVANIC AND CORROSIVE EFFECTS ALL STEEL WELDING RODS SHALL BE E7OXX ELECTRODES 5. MASONRY MASONRY UNITS SHALL BE ASTM C 145, GRADE N, BELOW GRADE; ASTM C 90, GRADE N, ABOVE GRADE WITH MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI ON NET AREA OF INDIVIDUAL UNITS. ALL MORTAR SHALL BE TYPE S (OR TYPE M) IN ACCORDANCE WITH ASTM SPECIFICATION C 270 WITH A MINIMUM COMPRESSIVE STRENGTH OF 1,800 PSI 0 28 DAYS, (2500 WITH TYPE M) GROUT SHALL BE A HIGH SLUMP MIX IN ACCORDANCE WITH ASTM SPECIFICATION C 478, HAVING A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI ALL CONCRETE MASONRY BEARING AND SHEAR WALLS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE SPECIFICATION FOR THE DESIGN AND CONSTRUCTION OF LOAD BEARING CONCRETE MASONRYP, PUBLISHED BY THE NATIONAL CONCRETE MASONRY ASSOCIATION. PROVIDE HOT DIPPED GALVANIZED TRUSS TYPE HORIZONTAL JOINT REINFORCEMENT (MIN. 9 Gk) AT 18' ON CENTER VERTICAL IN ALL MASONRY WALLS. PROVIDE DOVE TAIL SLOT ANCHORS AT CONCRETE COLUMNS. 5, TIMBER ALL STRUCTURAL TIMBER TO BE DOUGLAS FIR OR SYP 12 (MINIMUM STRESS GRADE LUMBER OR APPROVED EQUIVALENT) THE MINIMUM ALLOWABLE PROPERTIES ARE AS FOLLOWS: Fb = 1,150 PSI Fv - 90 PSI E = 1,400,000 PSI BE DESIGNED IN ACCORDANCE WITH THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION'S 'CONSTRUCTION MANUAL' AND PRESSURE TREATED FOR EXTERIOR USE ALL TIMBER AND TIMBER CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES AS SPECIFIED BELOW: AMERICAN INSTITUTE OF TIMBER CONSTRUCTION: TIMBER CONSTRUCTION MANUAL NATIONAL FOREST PRODUCTS ASSOCIATION: NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION AMERICAN PLYWOOD ASSOCIATION: PLYWOOD DESIGN SPECIFICATION AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS NATIONAL LUMBER MANUFACTURER'S ASSOCIATION: NATIONAL DESIGN SPECIFICATION FOR STRESS GRADE LUMBER AND ITS FASTENINGS ALL TIMBER CONNECTIONS ARE TO BE MADE USING PREFABRICATED CONNECTORS, TOE NAILING WILL NOT BE PERMITTED. FASTENERS TO BE AS MANUFACTURED BY SIMPSON OR APPROVED EQUIVALENT 8. WOOD HEADERS AT NON -BEARING CONDITIONS SHALL BE AS FOLLOWS: OPENING SIZE HEADER UP TO4'-0' (2)Tx6' 4'-0' TO 6'-V (2) 2' x 8' 81-0' TO 91-0' (2) 2' x 10' PROVIDE PRESSURE TREATED LUMBER WHERE LUMBER IS IN CONTACT WITH CONCRETE OR OUTSIDE OF BUILDING PLYWOOD ROOF SHEATHING 5(8' THICK STRUCTURAL 1 C-D INT APA PLYWOOD WITH EXTERIOR BLUE F I X T U R E S C H E D U L E MK. TYPE -- MANUF CATALOG NO. _..... MP 10990 _ 120 W-500A SP-160 LAMPS REMARKS _ - B 4 FCUbRE€Rf SU�CE tom. ILE WRAPARDUM _OIFFI PFR OIRCLINE 0 ON r0IFE 6CENi BURFACE MID. tMFFIJ6Eft ---- ULTRASONIC OCCUPANCY SENSOR, CEILING MTD. CEILING EXHAUST FAN LITHONIA _---. WATT STOPPER GREENHECK OR EQUIV. 40W T12 - --- —--....__ SURFACE MOUNTED — 22W CIRCLINE ------------.---- — MOUNTED C EF .SURFACE - — SURFACE MOUNTED F 0 U H L) H T T U N S C H E® U L E MARK SIZE REINFORCEMENT REMARKS F1020 T81212 10' x 20' 12' x 12' 12' x 24-'-344 345 BOTTOM 244 BOTTOM BOTTOM CONTINUOUS FOOTING THICKENED SLAB TS1224 THICKENED SLAB ® 0 D H S C H E® U L E NO. DOOR FRAME FIRE- RATING HOW. GROUP REMARKS SIZE MAT'L. TYPE GLASS LOUVER MAT'L. TYPE DETAILS WIDTH HT. THK. W H HEAD JAMB SILL HR LAB ORP KEY 1 3'-O' 8 8 3'-0' 8 8' - --� 3'_0' 8'-8'L1 -1-3/4' 1 3/4' 3/4' H.M. HM. - - H.M. A A A - -- _ --t H.M.1 H.M H.M. 1 1 VA1 VA1 - - - VA1 VA1 VA1 } VA1 - -- -- -- 1 1 2 -- ---- -- 2 3 ` - - - -- -HOLLOW METAL DOOR FRAME W13 0 0 -_ t T ANCHORS PER JAMB. FILL WITH C GROUT (JAMBS ONLY). C / HOLLOW METAL DOOR i CONT. CAULK BEAD - - 5/8' STUCCO ON 8' CONC NOTE,- BLOCK WALL, TYP. HEAD DETAIL SIMILAR DETAIL 1 SCALE: 3'=1'-0' Al 24 GA. 1 V2' STANDING SEAM METAL ROOF ON 301 ROOFING FELT & 5/8' PLYWOOD DECKING-_-- - - -5 ROOFING ALTERNATE- 20- YR FIBERGLASS SHINGLES ON 301 ROOFING FELT & 5/ PLYWOOD DECK TOP OF CONC BEAM ELEVATION 4-0' DooR HEAD ELEVATION i8'-10' 1' I r x 8' FASCIA... -- --- - - 5/8' STUCCO ON 8' CONC BLOCK- ---- --- OPEN O FLUSH, HOLLOW METAL DOOR W/CLOSED TOP & BOTTOM ICJ TYPE 'x4' ® 24' O.C. 2' x 4' FLY RAFTER 2 8' x 8' THK SLAB EDGE TYP. AT ALL EXP. SLAB ac x 1 Cllc4 Ar 0 ROOF FFiRMING PLRN SCALE: V4'=1'-0' HARDWARE SCHEDULE MANUFACTURERS USED IN THE FOLLOWING SETS: HINGES (BUTTE) STANLEY LOCKS, LATCHES & CYLINDERS SCHLAGE CLOSERS LON PUSH, PULLS & KICK PLATES ROCKWOOD STOPS & HOLr)ERS GLYNN�JOHNSON THRESHOLD PEMKO WEATHERSTRIPPING & DRIPSTRIPS PEMKO HARDWARE GROUP #1 1 112 PR BUTTS FEE 179 4 V2 x 4 V2 32D 1 CYLINDER 8863P 200 1 PUSH 1F70 26D 1 PULL #107 x 70 26D 1 CLOSER P1461 SC AL 1 KICK PLATE 8' x 2' L.D.W. 320 1 THRESHOLD 2005 AS AL 1 SET WEATHERSTRIPPING 290 AS HARDWARE GROUP 12 1 V2 PR BUTTS FBB 179 4 V2 x 4 V2 32D 1 LOCK SET DBOPD 'RHODES' 28D 1 CLOSER P1461 SC AL 1 KICK PLATE 8' x 2' L.D.W. 32D 1 THRESHOLD 2005 AS AL 1 SET WEATHERSTRIPPING 290 AS Y2 24 GA. 1 V2' STANDING EAM METAL ROOF 5I RI OF SLOPE ON 300 ROOFING FELT & 5(8' PLYWOOD DECKING-- - N' STLIGCC & MTL ILA ON 1 FELT J 3/4' ETTUCCQ & MTL LATH ON 151 F LT. & 5'8' PL ODD SH ING -- --•-� --- & 8/8' PLYWOOD SHEATHING TOP Of CONC BEAT STUCCO IX . JOINTSI P. �- ELEVATION i8'0 - DOOR HEAD STUCCO EXP. JOINTS, TYP. 1' 0 ELEVATION +6'-1P 1, OPEN T x 8' FASCIA- -- - - &8' STUCCO ON 8' CONC BLOCK / 24'FIN x 72 ALUM RAINLOUVERD IP CLEAN, ANODIZED FINISH. PROVIDE RAIN DRIP 8 INSECT SCREEN -- FINISH FLOOR ELEVATION +0'_ - - FINISH FLOOR �J -0' -` `" - - - - - - - - - - - - ELEVATION +0'-V 10' x 20' GONG FOOTINB _--___r _ - - - - _ _ _ _ _ _ -- - - - - 10' x 2T GONG FOOTING W1345 BARS CONT.-------- - - - - - - - - - -FRONT ELEVATION - - - - - - - - - W/3-6 BARS CONTr- �No o�unnm+�nimoulnune�nluno o�.� IrI — - V1 � o�uunmlllmm� o:nuuuuunmo RETE SLAB 6 MIL VAPOR - . �. ..T. IN FOUNDATION WALLS.- o S ■ n S i■' i IIIIIIIIIHIIIIIIIINIIIIUO aIIINIINIIIIIIIIIIINIHNNEIIIill0i111111H11 ANC ` PO R • . �. .• _ PROVIDETERMITE CONTROL TREATMENT UNDER SLABS I AND IN FOUNDATION WALL- l OINNHIIIIIHIIIHHIININ110 - - O�gtH11NHN111111NI1N �f , t— - HOLLOW METAL DOOR & FRAME \ -24' x 72' ALUM LOUVER W/CLEAR, \ ANODIZED FINISH. PROVIDE RAIN DRIP & INSECT SCREEN - - - - - FINISH GRADE ( - - - - - - - - - - - - - - - - - - - - - - - - - - - -I -� - - - - - - - - - - - - - - - - - - LEFT SIDE ELEVATION - ROOFING ALTERNATE: 20 YR FIBERGLAS----S - SHINGLES ON 30t ROOFING FELT 8 5(8` - - - - -- - - PLYWOOD DECK 12 12 24 GA. 1 STANDING SEAM METAL ROOF 24 GA. 1 1/2' STANDING AM METAL R I 5 SL PE \ \\OOF SLOPE 5 ON ROOFING FELT & 5 8 PLYWOOD ON 301 ROOFING FELT & /8' PLYWOOD DECKING- - ---- DECKING-- - -- TOP- OF CONC BEAM LOUD CONC BEA t--�-3( STUCCO & MTL LATH ON & >i hLYWOOD SHEATHING--� I& FELT ELEVATION +8'4 DOOR HEAD ELEVATION +8' U - - 0 EXP. JOINTS, TYP. / DOOR HEAD ELEVATION i8'-10' i - - - - - - - 1' x 8' FASCIA- -- --__�= , � \ r x 8' FASCIA--- -- - \ 58 STUCCO ON 8 CONC BLOCK- ---� / 6/8' STUCCO ON T GONG (LOCK-- > \ HOLLOW METAL DOOR & RAME- --- / _HOLLOW METAL DOOR & FRAME 24' x 72' ALUM LOWER VCLEAR, ANODIZED / FINISH. PROVIDE RAIN DR] & INSECT SCREEN < - - -- FINISH FLOOR \ FINISH FLOOR / ELEVATION +0'-0 - ELEVATION +0'-0' - FOOTING _ _-- -_ -_ -) _ - - - OARS CONi.- -- -._--- W/3-06 BARS CCONT.--- - - - - - - - - -- - - - - - - - - -_ - - 117 x 2P GONG FOOTING _ __r__._-� _ _ _ _ _ _ _ - - - - - -- REAR ELEVATION W/345 BARS CONT.- --_- - - - - - - - RIGHT SIDE ELEVATION - - - - - - - EXTERIOR E L E `/ R T I O N S THESE PLANS AND ALL PROPOSED WORK , SCALE: V4'4-9 ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES, A 7; - F1------F- - - - -- _ I� ^ - 3_4 L 8. - CFI I_ 8 m EL I CDOEF 1800�6 SERA BLO K CELL. FILLC. FOUNORTION PLRN SCALE: V4'=1'-0' 24' x 72' ALUM. WALL LOUVER W/IhRFf1T S(:RFFN--.-_ 1 I 1 a aiNnnm�.�a +o�Hnnm a T � ::. o�nunnuuumo auuuunnuleo !� � III 1 � I III O INIHNIIIIIIIIIIIIIIINII�AllllO!IIIIIINIIIIIIIIIIIIIIu111N111111110 SERVICE a - � C ioI1111 NIN11 NINIHHunNO o NminnnHlinnnlNlKim' MAIN BREAKER W/QOC12US COVER MAIN PANEL r PROTOTYPE FLOOR PLRN SCALE: V4'=1'-0' PLUMBING FIXTURE SCHEDULE ALUM. WALL WINSECT SCREEN ,i NED BY StLudeftrb REVIEWED BY '111V XZ, DATE 0p D PLANS AND PERMIT MUST BE KEPT ON JOB OR I nF n, ^,ne L-1 AMERICAN STANDARD 0321.026 DECLYN WALL -HUNG LAVATORY W/CONCEALED ARMS SUPPORT, WHITE, W/ SLOAN ETF-�86 FAUCET & ELF-10 SENSOR, BRASSCRAFT R1912A CHROME SUPPLY, 1 V4' CHROME PLATED P-TRAP, T7 GA WITH CLEAN OUT WC-1 AMERICAN STANDARD 2257.103 AFWALL EL 1.6, ELONGATED FLUSH VALVE TOILET, WALL HUNG, WHITE W/CHURCH 9500C OPEN FRONT LESS COVER,BOLT CAPS, AND SLOAN ROYAL 142 ES-S OPTIMA SYSTEMS CONCEALED FLUSH VALVE WC-2 AMERICAN STANDARD 2257.103 AFWALL EL 1B, ELONGATED FLUSH VALVE TOILET, WALL HUNG, WHITE W/CHURCH 95000 OPEN FRONT LESS COVER, BOLT CAPS, AND SLOAN ROYAL 142 ES-S OPTIMA SYSTEMS CONCEALED FLUSH VALVE (MOUNT WITH SEAT HEIGHT OF 20' A.F.F.) STEBBINS, SCOTT & BERGMAN ARCHITECTS,P.A. 2101 SUNRISE BLVD #AA C001468 FORT PIERCE. FLORIDA 561-4&4-3122 34950 St. Lucie Cod* seen I Sdv mmental amen Septle System Appm Ad For Proposed Construction This Amroval DoEs Not Gi 6 norXf am e1=MST.ILUCIE COUNT >vievv�r:IaUa4acifity djL- SCALE: APPROVED BY: DRAWN BY DATE: 07(15(96 1 REVISED Board of County Commissioners St. Lucie County, FL DRAWING NUMBEI Job No. 95-1136 1 Sheet Al c \ c \ \ T ' JI 24' x 77 ALUM. LOWER W/INSECT SCREEN & CLEAR, ANODIZED FINISH OA2 DISPENSER/WASTE SURFACE MOUNTED 30' X IF MIRROR JN S FRAME- + SOAP DISPENSER-� OA2 IMM GRAB 2 COATS BLOCK FILLER &EPDXY PAINT ON EXPOSED GONG BLOCK SOLID PLASTIC OVERHEAD BRACED TOILET PARTITIONS WALL -HUNG H.C. TOILET v M NOTE: ACCESSIBLE TOILET ROOMS SHALL MEET ALL APPLICIBLE STANDARDS OF THE AMERICANS WITH DISABILITIES ACT, FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS ACCE�;IBILTTY REQUIREMENTS MANUAL AND CHAPTER 15,53, FLORIDA STATUTES INTERIOR ELEVATIONS SCALE: NEI'4-0 7_00�•01 HgL�lSg, PULLS, LATCHES, LOCKS, AND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A FHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGtfT GRASPINQ TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. LEVER-0PFRATED MECHANISMS, PUSH TYPE MECHANISMS, AND U SHAPED HANDLES ARE ACCEPTABLE DESIGNS. WHEN SLIDING DOORS ARE FULLY OPEN, OPERATING HARDWARE SHALL IXPC6ED AND USABLE IHOM BOTH SIDES. HARDWARE RC-0UIRED FOR ACCESSIBLE DOOR PASSAGE SHALL BE MOUNTTED NO HIGHER THAN 48 IN ABOVE FINISHED FLOOR 4.13.10 DOOR CLOSERS IF A DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 IN FROM THE LATCH, MEASURED TO THE LEADING EDGE OF THE DOOR. (2) q GEiAB BAR SHALL BE INSTALLED AT A HEIGHT OF 33 INCHES, MEASURED BY THE VERTICAL DISTANCE FROM THE FINISH SURFACE OF THE FLOOR TO THE TOP OF THE RAIL, WITH AN ALLOWABLE VARIATION OF NOT MORE THAN 05 INCHES. 4.192 LAVATORY HEIGHT & CLEARANCES LAVATDRIES SHALL BE MOUNTED WITH THE RIM OR COUNTER SURFACE NO HIGHER THAN 34 IN. ABOVE DIE FINISH FLOOR. PROVIDE A CLEARANCE OF AT LEAST 29 IN. ABOVE THE FINISH FLOOR TO THE HOTTOM OF THE APRON. 4.193 LAVATORY CLEAR FLOOR SPACE A CLEAR FLOOR SPACE 30 IN. BY 48 IN. COMPLYING WITH 424 SHALL BE PROVIDED IN FRONT OF A LAVATORY TO ALLOW FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19 IN. UNDERNEATH THE LAVATORY 4.19.4 LAVATORY EXPOSED PIPES AND SURFACES HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL 13E NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. 4.195 FAUCETS FAUCETS SHALL COMPLY WITH 427.4. LEVER OPERATED PUSH -TYPE, AND ELECTRONICALLY CONTROLIED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. IF THE SELF-CLO61NO VALVES ARE USED THE FAUCET SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS. 4.198 MIRRORS MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE NO HIGHER THAN 40 IN. ABOVE THE FINISH FLOOR. ALTERNATE ROOFING' --- _-.-_-.—_— 2060 MIN. FIBERGLASS SHINGLES ON 2 LAYERS %# ROOFING FELT TIN TAGGED TO 19137 EXPOSURE 1, C-0 SHEATHING GRADE PLYWOOD WITH LONG DIMENSION PFRPINDICULAR TO FRAMING MEMBERS AND END JOINTS STAGGERED. 1 1/2' 24 GA. STANDING SEAM METAL ROOF & 2 LAYERS 150 ROOFING FELT TIN -TAGGED TO SS' C-D SHEATHING GRADE PLYWOOD USE 10d RING SHANKED NAILS ® 4' O.C. AT ALL EDGES AND INTERMEDIATE SUPPORTS, FOR ALL FASTENING 6' OR LESS FROM ROOF EDGE: USE 10d COMMON OR HOT DIPPED GALV. BOX NAILS ® 8' O.C. AT ALL EDGES AND INTERMEDIATE SUPPORTS ELSEWHERE 12 5 ROOF SLOPE -,- TRUSSES m 240O.C. V7 PLYWOOD SOFFIT -6l8 M.R. GYPSUM DRYWALL CEILING WIX CONT. ALUM. VENT-- /'a0000 -- t T x B' FASCIA ON 2' x 4' SUB -FASCIA = 'Y6 4 Mfg CA4LIG 1 ;-w n . L1' 0' MTI. Tn r, A-�L �1 IPnn IJ.. yg STUCCO ON 8' CONIC EIEAM --- 5'8' STUCCO ON 8 CONIC BLOCK COLUMN--- ----- _rnlL 91G1[!/ GPiees4.►�a �soiT'"t ♦. i'1 Hlrl TOP OF GONG BEAM ELEVATION +8'-V A SIMPSON OSS1B, TYPICAL 0 EACH TRU11 -- -8' x 18' GONG BEAM W/246 EARS TOP & BOTT. GOUT. '1 RAISE BEAM BOTTOM 2' ® DOOR & LOUVER OPENINGS. °o_4I PROVIDE SIMPSON ETAITSS 20 0 ENDS OF EACH TRUSS SECTION A SCALE: 3/4'=1'4 A2 rALTERNATE ROOFING: 285I MIN. FIBERGLASS SHINGLES ON 2 LAYERS W ROOFING FELT TIN TAGGED TO IR/37 EXPOSURE 1, GD SHEATHING GRADE PLYWOOD WITH LONG DIMENSION PERPINDICULAR TO FRAMING MEMBERS AND LEND JOINTS STAGGERED. 1 112' 24 G4 STANDING SEAM METAL ROOF & 2 LAYERS 12 161 ROOFING FELT TIN -TAGGED TO 5/8' C-D SHEATHING GRADE PLYWOOD 5 ROOF SLOPE PLYWOOD---- __ -- ----_ ___-__._. _ __.-- USE 10d RING SHANKED NAILS ®4' O.C. AT ALL EDGES AND INTERMEDIATE SUPPORTS FOR ALL FASTENING 5' OR LESS FROM ROOF EDGE; USE 10; COMMON OR HOT DIPPED GALV. BOX NAILS ® 8' O.C. AT ALL EDGES AND INTERMEDIATE / SUPPORTS ELSEWHERE - E— —PRE-ENGINEERED WOOD V7 PLYWOOD SOFFIT TRUSSES ® 24'OC. W/3' CONT. ALUM. VENT � �cLg MR. GYPSUM DRYWALL CEILING 1' x 6' FASCIA ON (f° �I 2 x 4' SUB FFvSCIA- -- SIMPSON ETA/TSS18, TYPICAL oU TRUSS BEARING 0 ---8 x 18' CONC BEAM W/246 BA ^v rA Mr, AGPLic �' nr r .. 1' 0 0 RAISE BEAM BOTTOM 7 ®D00 y.;, enn rs. PROVIDE SIMPSON ETAITSS 20 1 -- --319 CONT. REVEAL ® EXPOSED 8 x 8' x 1B' CONCRETE MAE S(g STLOCO ON El_ E3 UNITS IN V2 RUNNING BOND T GONG BLOCK ____ --_- -_-__ __ \-- 4' 3000 PSI GONG SLAB W/B HOT DIP)ED GALV MASONRY TIES COMPACTED (96% DRY DENS ® 18' 00 VERT.-- UNDER ALVSLAESWAND FOO TURN VAPOR BARRIER UP A TO CREATE BOND BREAK I I � r" :19•I� iL v w 1 I U?' \� Pm. �e d•n sLu d^ we �i I � '� % od► se?hw �recx c o� Lnv FL PrA ti t:7 i We 1117 D�•- � :AM // 1 � aaµ8� Wi Tn o[o'!.L,T•�An�r •.nCa�:.rLo �i.4 RiFAD IN( O7: U+al �rRl+fr ufc=TL' f^'+E?r tic- l 4" h ppeCnVlvE 40R, Rvcu 4r Pvy d"m 'CA •sslru AAA C! Iti_A _� o "o "o "o oQ 0� oQ o ' ob' 006 00 �00 D� � �(qq -,A rSTEBBINS. SCOTT & BERGMAN1 ARC HITECTS,P.A. 2101 SUNRISE BLVD #AA Coo 1468 FORT PIERCE. FLORIDA 5614fi4-3122 34050 Fn.L BA4.str r s.!ELLA44 6Arr TOP OF CONC BEAM ELEVATION +8'-T & BOTT. CONT. NER OPENINGS. OF EACH TRUSS BARRIER ON CLEAN, 1. REINFORCE SLAB J�t) FINISH FLOOR ELEVATION +0'-0' \\\ L11 TOP OF GONG FOOTING LE ELEVATION 2V CONCRETE FOOTING W/346 BARS CONT. RNE L FIENDS (LAP SPLICES MIN. 25� SECTION_ SCALE: 314'4-0' A2 S B EU SttudeCouMv ST. LUCIE COUNTY P ototype Toilet Facility SCALE: APPROVED BY: DRAWN BY DATE: 07/15/96 REVISED Board of County Commissioners 24 Y 36 PRINTED ON NO. lOOON CEARPRINT• Job No, 95-1136 DRAWING Nl Sheet A