HomeMy WebLinkAbout1303-0120- PRODUCT APPROVAL ROOFING UNDERLAYMENTFlorida Building Code Online Page 1 of 2
BY
Business & Professional Regulation
r
Florida Departments eCiS Home I Login I User Registration I IHot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search I
Busines *USER:
Product Approval
Professi I Public User
Regulation
Product Approval Menu > Product or Apol
FL #
Application Type
Code Version
Application Status
Comments
Archived.
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory.
Compliance Method
Florida Engineer or Architect Name
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expirat
Validated By
Certificate of Independence
Referenced Standard and Year (of
> Application List > Application Deta
FL5259-R17
Revision
2010
Approved
C
POLYGLASS USA
150 Lyon Drive
Fernley, NV 89408
(570)384-1230 Ext242.
jakins@polyglass.com
James Akins
jakins@polyglass.com
Steve Wadding
150 Lyon Drive
Fernley, NV 98408
(602)363-7139
stevew@polyglass.com
James Akins
555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800) 894-4563
jakins@polyglass.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑✓ Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
Date 08/08/2015
John W. Knezeyich, PE
0 Validation Checklist - Hardcopy Received
FL5259 R17 COI Trinity ERD CI - Nieminen.r)df
Standard Year
ASTM D1970 2001
ASTM D226 2006
ASTM D6164 2005
http://www.floridabuilding.org/pr/pr_app_,
EVXQwtDgvbSgAaZp3 Crk... 3/14/2013
Florida Building Code Online Page 2 of 2
ASTM D6222 2002
ASTM G154 2005
ASTM G155 2005
FM 4474 2004
FRSA/TRI07320 2005
TAS 103 1995
Equivalence of Product Standard_ s
Certified By
Sections from the Code
Product.Approval Method Method 1 Option D
Date Submitted 12/07/2012
Date Validated 12/11/2012
Date Pending FBC Approval 12/18/2012
Date Approved 02/04/2013
Summary of Products
FL #
Model, Number
or
Description
Name
5259.1
Polyglass Roof
Roofing underlayments
Underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: Plo
FL5259 R17 II er120712FINAL POLYGLASS UNDERLAYMENTS FL5259-
R17.Ddf
Approved for use outside
HVHZ: Yes
Verified By: Robert Nieminen PE-59166
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-622.5
Other: 1.) The design pressurd
in this
Evaluation Reports
FL5259 R17 AE er120712FINAL POLYGLASS UNDERLAYMENTS FL5259-
R17.odf
application relates to one partic�R'
ar
underlayment system for use uer
Created by Independent Third Party: Yes
foam -on tile systems. Refer to
Section 5.5.2 for other.systems
and
maximum design pressures. 2.)
Refer
to ER Section 5 for other limits
of use.
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovrioht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not
send electronic mail to this entity. Instea6, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395.
"Pursuant to Section 455.275(1), Florida (Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails'provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
® M eCheik
M.
Credit
SArFE
http://www.floridabuilding.org/pr/pr_app�dtl.aspx?paratn=wGEVXQwtDgvbSgAaZp3 Crk... 3/14/2013
ot
EVALUATION REPORT
Polyglass USA, Inc:
150- Lyon Drive
Fernley, NV 98408
SCOPE:
This Evaluation Report -is issued und(
the use of construction materials in
reviewed,.by Robert Nieminen, P:E.
Florida Building .Code; Residential VI
comply with the.2010 Florida Buildin
DESCRIPTION.: Polyglass Roof Undl
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
. CHRISTIAN STREET,_UNIT.#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243'
Evaluation Report_ 1312060.02.09-1112
FL5259-R17
Date of Issuance: 02/24/2009
Revision 12: 12/07/2012
Rule 9N-3 and the applicable rules and regulations governing
:he State of Florida. The -documentation submitted has been
br use of the,'product under:.the Florida Building.:Code and,
ume. The products described herein have been designed to
Code sections noted herein.
LABELING:. Each 'unit shall bear labeling in accordance with the requirements the Accredited. Quality
Assurance Agency noted herein. -
CONTINUED 'COMP.LIANCE:. This EValu tion Report is valid until such time as the, named.'product(s)
changes, the referenced Quality Assurance documentation changesj or provisions,o ,the. Code that
relate to the 'product change. Accept#ance.of this- Evaluation Report by the named client constitutes
agreement to. notify Robert Niemi.en; P.E. if the product. changes or the referenced Quality
Assurance, documentation changes. Trinity[ERD requires a complete review of this Evaluation
Report relative to..updated Code requ rements with each Code Cycle:
ADVERTISEMENT:.The'Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature If any portion of the Evaluation Report is. displayed,. then it
shall be done in .its entirety.
INSPECTION::: Upon request, a copy of this entire Evaluation Report shall be .provided to the userby'
the manufacturer- or its distributors and shall be available for inspection at thejob job site at . the
request of the Building Official..
This Evaluation Report consists of pages 1 through 10.
Prepared by:
RobertJ.M., Nieminen, P.E.
Florida Registration No. 59166, Florida DCA All
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor._does it intent
distributing products it evaluates.
2. TrinitylERD is not owned, operated or controlled
3. - Robert Nieminen, P.E. does not have nor will act
the evaluation reports are being issued. .
4. Robert Nieminen, P.E. does not have, nor will
product.
6° +' The facsimile seal appearing was authorized
by Robert Nieminen, P.E: on 12/07/2012
• ;' p�,•^�, , ,; .,c f M1 ; . This does not serve as an electrohlcally signed
• 3„ document. Signed, sealed hardcopies have been
E1983 �'�S'o�rJ�q��.k. ; transmitted. to the Product Approval Administrator and
4�.JJi�rn��'n to the named client
to acquire .or will it acquire, a financial interest in any company manufacturing or
by any company manufacturing or distributing products it evaluates.
uire, a financial interest in any company manufacturing or distributing products for which
acquire,- a financial interest in any other entity involved in the approval process of the
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underla
Compliance Statement: . Roi
demonstrated. compliance with th
accordance with the following Sta
Limitations / Conditions of Use set
2. STANDARDS:
�l l'RINIIY ERD:
anent
if Underlayments, as produced by Polyglass USA, Inc., have
following sections of the Florida Building Code through testing in
idards. Compliance is subject to the Installation Requirements and
forth herein.
Section
Property
Standard
Year
1507.2.3, 1507.3.3, 1507.5.3,.
1507:7.3,=1507.8.3, 1507.9.3
Phy�ical Properties
ASTM D226
.2006
1.507.2.4, 1507.2.9.2, 1507.3.3,
1507.5.3
Physical Properties
ASTM D1970
2001
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2002
1504.6
Accelerated Weathering
ASTM G154
2005
1504.6
Acc lerated Weathering
ASTM G155
2005
1504.3.1
Wind Uplift
FM 4474
2004
1507.3.3
Instpllation Practice
FRSA/TRI 07320
2005
1523.6.5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES'
Entity
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRIO1111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physlical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878) .
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003.
PRI (TST 5878)
Phy ical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Phy ical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878).
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
_
Phy ical Properties,
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Phy ical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Phy ical Properties
PUSA-076-02-01
02/22/2008.
PRI (TST 5878)
Phy ical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Phy ical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
ERD 6049)
Physical Properties
Win Uplift
11752.09.99-1
11776.06.02
02/08/2000
01/16/2003
(TST
ERD (TST 6049)
I
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-R1
11/30/2009
ERD (TST 6049)
Phys cal Properties
P11030.11.09-1
11/30/2009
ERD (TST 60491
Wind Uplift -
P11030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties "
P11030.11.09-3
11/30/2009
ERD .(TST 6049)
Physical Properties
P33360.06.10
06/25/2010
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
ERD (TST 6049)
Physical Properties
P33370.04.11
04/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1112
Certificate of Authorization #9503 F11-5259-1117
Revision 12: 12/07/2012
Page 2 of 10
TRINITY .ERE �
Entity Ex mination Reference Date
ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD (TST 6049). Physical Properties C41420.09.12-3 09/11/2012
ICC-ES (EVL 2396) IB G Compliance ESR-1697 11/01/2011
Miami -Dade (CER 1592) HV Z Compliance NOA Current
Polyglass USA Ma iufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008
Polyglass USA Ma erials Affidavit Polystick SA Compound 08/18/2011
UL, LLC. (QUA9625) Qu�lity Control Service Confirmation Exp..08/08/2015
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlavments:
4.1:1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a. polyesterreinforced, SBS modified bitumen base sheet.
4.2 Self-Adherina Underlayments:
4.2.1 Polystick MTS is 'a nominall60-mil thick rubberized asphalt waterproofing membrane; glass fiber
reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103.
4.2.2 Polystick IR-Xe is a norm al 60-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced, with an aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU is a nominal i00-mil thick rubberized asphalt waterproofing membrane, glass fiber
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.4 iPolystickTU Plus is a no inal 80-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane,. glass-
fiber/polyester reinforced With a granular surface; meets ASTM D1970. and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a
170 g/m2 polyester fabric surface; meets TAS 10.3.
4.2.7 Polyflex SAP, PolyFlex, SAPS FR, Mule -Hide SA-APP Cap Sheet a'nd Mule -Hide SA-APP Cap Sheet
(FR) are a polyester reinforced, APP modified bitumen cap sheets.
4.2.8 Dual ProTM is a nominal 6i0-mil thick dual -layer rubberized asphalt waterproofing membrane,
fiberglass reinforced, with a polyester fabric surface.
4.2.9 Tile PrOTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane,
fiberglass reinforced, with apolyester fabric surface.
4.3 Mechanically Fastened aI d/or Bonded Underlavments:
4.3.1 Elastoflex S6 G and Ela
sheets.
4.3.2 Polyflex G and Polyflex G
S. LIMITATIONS:
5.1 This Evaluation Report is
S6 G FR are polyester reinforced, SBS modified bitumen cap
are polyester reinforced, APP modified bitumen cap'sheets.
for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory. for fire ratings of this product.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report P12060.02.09-11112
FL5259-R17
Revision 12: 12/07/2012
Page 3 of 10
5.3 Polyglass Roof Underlay
specifically referenced v
to the AHJ for approvi
prepared roof covering.
O
�l 1' RINITY IfRp.
ents may be used with any prepared roof cover where the product is
hin FBC approval documents. If not listed, a request may be made
based on this evaluation combined with supporting data for the
S a AIlnwnhie rnnf rnverc nnnlieri atnn the itnrlerlavments are as fnllnwc-
Table 1: Roof Cover Options
Underlayment
Asphal
Nail -On Tile
Foam -On
Metal
Wood
Shakes &
Slate
Shingle
Tile
Shingles
Elastobase
Yes
Yes
No
Yes
Yes _
Yes
Elastobase P
Yes
Yes
No
Yes
Yes
Yes
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick TU
Yes
Yes
es
No
Yes
Yes
See
5.Polystick
TU P
Yes I
Yes
es
No
Yes'
Yes
See
5.Polystick
TU Plus
Yes
Yes
es
Yes
Yes
Yes
See
5.Yes
Polystick TU Max
No
Yes
No
No
No
See 5.4.1
Dual Pro.
Yes
Yes
No
Yes
Yes
Yes
Tile Pro
Yes
Yes
Yes
Yes
Yes
Yes
1
See 5.4.1
Elastoflex S6 G
Yes
Yes
es
No
Yes
Yes
See
5.Elastoflex
S6 G FR
Yes
Yes
No
No
Yes
Yes
Polyflex G
Yes
Yes
es
No
Yes
Yes
See
5.Polyflex
G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
See 554.1 Ye
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
Yes
I
Yes
Yes
No
Yes
Yes
or SA-APP Cap Sheet (FR)
See 5.4.1
5.4.1 "Foam -On Tile" is limiter
adhesion / long term agin,
➢ Polyfoam PolyPro A
G, Polyflex G, Polyflex
SA-APP Cap. Sheet (FR
➢ 3M11" 2-Component I
➢ Dow TileBond: Polys
➢ Convenience Produc
Plus, Polystick TU Max
5.4.2 For nail -on the systems o
tile.
5.4.3 A 2-ply underlayment Sys
P, TU Plus or TU Max, c
prepared roof systems.
system is desired.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
to use of the following Approved tile adhesives unless tensile
data from an accredited testing laboratory is provided.
160: Polystick TU, Polystick TU P, Polystick TU Plus, Elastoflex S6
AP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide
or Tile Pro.
oof Tile Adhesive AH-160: Polystick TU Max
ck TU P, Polystick TU Plus, Pol'yflex SAP or"Tile Pro
a' Touch 1n Seal StormBond Roof Tile Adhesive: Polystick TU
r Polystick MTS, battens are required for loading / staging of the
m, consisting of Polystick MTS followed by Polystick MTS, TU, TU
Polyflex SAP is allowable for use under mechanically attached
is is not a requirement, but is allowable if a 2-ply underlayment
Evaluation Report P12060.02.09-1112
FL5259-R17
Revision 12: 12/07/2012
Page 4 of 10
TRINl , ,Y ERQ,
5.5 Allowable substrates are noted below:
5.5.1 Direct -Bond to Deck:
Polystick, Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP
Cap Sheet (FR) self-adh red to:.
➢ New untreated plywood
➢ ASTM D41 primed new I ntreated plywood;.
➢ Existing plywood;.
➢ ASTM D41 primed existi • g plywood;
➢ ASTM D41 primed OSB; .
➢ Southern Yellow Pine
➢ ASTM D41 primed Sout ern Yellow Pine;
➢ ASTM D41 primed struc ural concrete;
➢ .Huber Engineered Wood 'ZIP System".Panels (designed and installed. to meet wind loads for project).
Note: Polyglass does n t require priming of new or existing plywood sheathing. New or
existing. plywood sheat ing should be cleaned :of all dirt and debris prior to application of
Polystick membranes.
Elastoflex S6-G or S6 G II R in hot asphalt to:
➢ ASTM D41 primed structLral concrete.
Polyflex G or.(jFR torch applied to:
➢ ASTM D41 primed structtral concrete.
5.5.2 Wind Resistance for Unc
does not address wind
systems, where the unc
limitations apply'to unde
used in'foam-on.tile ap-p
load resistance based or
design wind- pressures.
rlavment Systems in Foam -On Tile Applications: FRSA/TRI 07320
)lift resistance of all underlayment systems beneath foam -on tile
rlayment forms part of the load -path.. The following wind uplift
ayment systems that are not addressed in FRSA/TRI 07320.and are:
rations. Maximum Design Pressure is the result of. testing -for wind
allowable wind loads. Refer to FBC.1609:1.5 for determination of-
5.5.2.1 Maximum-Desian Pressurle = -622:5 qsf.
Deck: _ Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM .D 1
Underlayment: Elastofle S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -
applied.: .
5.5.2.2 Maximum Design Pressure = -315 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer:: ASTM D 11
5.5.2.3
Underlayment: Polystick TU; Polystick TU P, Polystick TU Plus, .Polystick. TU Max, Tile Pro, .
Polyflex AP,.PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide
SA-APP Cap Sheet (FR).
Maximum Desian Pressur8 = -135 psf.
Deck:. Min. 15/i2-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optionally ASTM D41
Joints: Min. 4-inch wide strips -of Elastoflex SAN over all plywood joints.
Underlayment: Polystick. U; Polystick.TU P, Polystick TU Plus, Polyflex SAP,. P.olyF.lex'SAP FR,
Mule-Hide
Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR)
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R12
Certifcate of Authorization #9503 FL5259-R17
Revision 12: 12/07/2012
Page 5 of 10
�I TRIMTY � ERa
5.5.2.4
Deck:. Min. 15%32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Underlayment: Polystick TU, Polystick TO P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR,
Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR)
5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on the systems
carry a Maximum Desig Pressure of -45 psf.
5.5.3 Bond -to -Insulation:
➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
self -adhered to: AI�STM C1289, Type II, Class 1 polyisocyanurate or Type V
polyisocyanurate-composite' insulation; DensDeck DuraGuard; DensDeck Prime; or
SECUROCK Gypsum- fiber Roof Board.
➢ Elastoflex S6 G or S6'G FR in hot asphalt•to: DensDeck Prime or SECUROCK Gypsum -Fiber
Roof Board.
➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck
Prime or SECUROCK Gypsum -Fiber Roof.Board.
For installation under mechanically attached prepared roof coverings, insulation shall be
attached per minimum requirements of the prepared roof covering manufacturer's Product
Approval. For installations under foam -on tile systems, insulation attachment shall be
designed by a qualit�ed design professional and installed based on testing of the
insulation/underlayment systemin accordance with .FM 4470, Appendix K or TAS 114,
Appendix J.
5.5.4 Bond to Mechanically Attached Base Laver:
5.6
5.6.1
5.6.2
5.6.3
5.6.4
5.6.5
➢ Polystick; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase
P or Mule -Hide Nail Base.
➢ Elastoflex S6 G or S6 G FR in hot asphalt to: ASTM D226, Type I or II felt, Elastobase;
Elastobase P or Mule Hide Nail Base.
➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base.
For installations under mechanically attached prepared roof coverings, base layer shall be
attached per minimum codified requirements. For installations under foam -on tile systems,
base layer shall be atta hed per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120.
Exposure Limitations:
Elastobase, Elastobase P, shall not be left exposed for longer than 30-days after installation.
Polystick IR-Xe, Polystick TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than
90-days after installation..
Polystick MTS, TU, TU p or TU Plus shall not be left exposed for longer than 180-days after
installation.
'Polyflex SAP or SAP FRS or Mule -Hide SA-APP Cap Sheet or SA=APP Cap Sheet (FR) does not
have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in
which ,case the maximum exposure is 30 days.
Elastoflex S6 G or S6 � FR or Polyflex G or G FR does not have an exposure limitation, unless
the prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G), in which
case the maximum exposure is 180 days.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-11112
Certificate of Authorization #9503 FL5259-R17
Revision 12: 12/07/2012
Page 6 of 10
I EftD
5.7 For tile. roof installatior s governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition, use is limited o the following. Reference is made to the FRSA/TRI Technical Brief
titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of
02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems.
Table 3: Tile System Options per FRSA/TRI.07320/8-05
System
Underlay
Section)
Reference
Product(s)
Option
3.02A
1
Batten
Modified Cap Sheet
Elastoflex S6 G or Elastoflex S6 G FR; Polyflex G'or G FR
only
No. 30/'Modified Cap
Base Layer: Elastobase; Elastobase P
System One:
2
3.02B
Sheet
Top Layer: Elastoflex S6 G or Elastoflex S6 G FR; Polyflex G or G
Mechanically
FR
Fastened Tile,
4
3.02D
No. 30
Elastobase; Elastobase P
Unsealed or:
Self -Adhered
Polystick MTS; TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP
Sealed
"
5
3.02E
Underlayment
FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR);
Underlayment
Dual Pro; Tile Pro
System
Base Layer:,ASTM D226, Type II; Elastobase; Elastobase P; ,
No. 30 / Self -Adhered
Mule -Hide Nail Base
6
3.02F
Underlayment
Top Layer: Polystick MTS; TU; TU P; TU Plus; TU Max; Polyflex
SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet (FR); Dual Pro; Tile Pro
3.62A
1
Batten
Modified Cap Sheet
Elastoflex S6 G or Elastoflex S6 G FR; Polyflex G or G FR
only
No. 30 / Modified Cap
Base Layer: Elastobase; Elastobase P
System Two:
2
3.02E
Sheet
Top Layer: Elastoflex S6 G or Elastoflex S6 G FR; Polyflex G or G
Mechanically .
FR
Self -Adhered
Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or'SAP FR;
Fastened Tile,
Sealed
4
3.02D
Underlayment
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual
Underlayment
Pro; Tile Pro
System
Base Layer: ASTM D226; Type II; Elastobase; Elastobase P;
No. 30 / Self -Adhered
Mule -Hide. Nail Base
5
3.02E
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; TU Max;. Polyflex SAP or
SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Dual Pro; Tile Pro,.
1
3.02A
Modified Cap Sheet
Elastoflex S6 G or Polyflex G
2
3.02B I
No. 30 / Modified Cap
Base Layer: Elastobase; Elastobase P
System Four "A":
Sheet
Top Layer: Elastoflex S6 G or Polyflex G
Adhesive -Set Tile,
4
3
I
Self -Adhered
Polystick TU; TU P; TU Plus; TU Max; ,Polyflex SAP or SAP FR;
Unsealed or
.02D
Underlayment
Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Sealed
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
Underlayment
. Mule -Hide Nail Base
System
5
3.02E
No. 30 / Self -Adhered
Underlayment,
Top Layer: Polystick TU; TU. P; TU Plus; TU Max; .Polyflex SAP or
SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet (FR)
1
3.02A
No. 30 / Modified Cap
Base'Layer: ASTM D226, Type II; Elastobase; Elastobase P
.
Sheet
Top Layer: Elastoflex S6 G or Polyflex G
System Four "B":
3
3.02C
Self -Adhered
Underlayment
Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR;
Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP.Cap Sheet (FR)
Adhesive -Set Tile,
Sealed
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
Underlayment
Mule -Hide Nail Base
System
4
3.02D
No. 30 / Self -Adhered
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or
SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet (FR)
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1112
Certificate of Authorization #9503 FL5259-R17
Revision i2: 12/07/2012
Page, 7 of 10
6. INSTALLATION:
6.1 Polyglass Roof Underli
installation requiremen
specifics noted below.
6.2 Re -fasten any loose c
substrate thoroughly b
substrate (if.applicable)
6.3 Elastobase, Elastobas
6.3.1
Shall be installed. in cc
underlayment in FBC Se
6.3.2
For use in non -tile appli(
6.3.2.1
Reference is made to tl-
recommendations for in:
6.3.2.2
Elastobase, Elastobase
Polyflex SAP or SAP FR,
Tile Pro; self -adhered, E
applied.
6.3.3
For use in tile. applicatio
conjunction with FRSA,
herein.
6.4
PolYstick MTS, IR-Xe,
nQ
�I I! RINITY I ERp
�ments shall be installed in accordance with Polyglass published
s subject to the Limitations set forth in Section 5 herein and the
,king panels, and check ,for protruding .nail heads. Sweepthe
remove any dust and debris prior to application., and prime the
mpliance with the codified requirements for ASTM D226, Type II
:tions 1507 for the type of prepared roof covering to be installed.
Awl
current edition of the NRCA Steep -slope Roofing Manual and ARMA
Iling shingle underlayments and flashings
or Mule -Hide Nail Base may be coveredwith a. layer of Polystick,
ule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or
stoflex S6 G or S6 G FR in hot asphalt or .Polyflex G or G FR, torch
reference is made to Polyglass published installation instructions in
1 07320/8-05 Installation Manual, Fourth Edition, and .Table 2
6.4.1 Shall be installed in combliance with the codified requirements for ASTM D1970 underlayment
in FBC Sections 1507 forlthe type of prepared roof covering to be installed.
6.4.2 For non -tile applications:
6.4.2.1 All self -adhering materiz
and Mule -Hide SA-APP C
edge seam in accordan
corrosion resistant, 11 g
Simplex -type metal cap
nailed using the above
clavar" on the face of m
nailed
6.4.2.2 All seal -lap seams (selvz
ensure full contact and a
the end of the -glue patte
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Is, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR
3p Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage
:e with Polyglass / Mule -Hide Back Nailing Guider Nails shall be
iuge ring -shank type.with a minimum 1-inch diameter metal_ disk or
sail, at a minimum rate of 12" o.c. Polystick TU Plus should be back-
ioted fasteners and spacing, in area marked "nail area, area para
:mbrane. The head lap membrane- isto cover the area being back -
laps) must be firmly rolled with a minimum 28 lb. hand roller to
esion. For Dual Pro and Tile Pro, align the edge of the top sheet to
(the sheet will overlap the fabric).
Evaluation Report P12060.02:09-1132
FL5259-R17
Revision 12: 12/07/2012
Page 8 of 10 .
TRINITY ;ERD
View of Ovelap Seam of JDual Pro and Tile Pro
6.4.2.3 All over -fabric and ove9ranule end -laps shall have a 6-inch wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing
Cement, Polyglass PG5 1.0 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing
Cement, Mule -Hide 241tement,
Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry
Electrometric Flashing or, Mule -Hide 421 Mod Bit .Flashing Adhesive Trowel Grade
mastic, applied in between the application of the lap:
6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as
crickets, exposed valleys, or exposed roof to wall details
6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55
Premium Modified Flash, ing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flasshing Cement, Polystick TU Plus Tile Underlayment Flashing Cement,
Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry
Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade
mastic to the area in need of repair, followed by a minimum: 6 x 6 inch patch of the Polystick
material of like.kind,.seli and hand .rolled in place. over the repair area. Patch laps, if needed,
shall be installed in a water shedding manner.
6.4.2.6 All Polystick membranes shall be installed to ensure full .contact with approved. substrates.
Polyglass. requires, a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff
broom with approximately 40-lbs of _load applied for the field membrane. Hand rollers are
acceptable for rolling of 'Patches,. laps (min. 28 lb'roller) or small areas of the roof that are not
accessible to a large roller or broom.
6.4.3 For tile applications (not allowed for Polystick IR-Xe):
6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as
a guideline.
6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
6.5 Elastoflex S6 G or S6 G FR:
6.5.1 Elastoflex S6 G or S6 G FR shall be installed 'incompliance with current Polyglass published
installation requirements. For use in tile applications,. reference is made to FRSA/TRI
07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1112
Certificate of Authorization #9503 FL5259-1117
Revision 12: 12/07/2012
Page 9 of 10
6:5:2 Elastoflex S6 G or-S6 FR shall be fully asphalt -applied to the..substrates.noted.in Section
.5.5, Side laps'shall be minimum- 3-inch and end -laps minimum 6-inch wide, and offset end
laps minimum 3 feet'f om course to course. .Side and end laps shall be fully adhered in a
complete mopping of: of asphalt with asphalt extending approximately 3/8-inch beyond the
lap edge.
6.6 - Polvflex G or G FR:
6.6.1 Polyflex,G or G'FR shall be installed incompliance with current Polyglass published installation
requirements.. For se _ in tile applications, reference is made FRSA/TRI .07320/8-05.
Installation Manual, Fo rth Edition,, and Table•2 herein. .
6.6.2 'Polyflex G or G FR she II be fully_ torch -applied. to.the substrates noted in Section 5.5. Side•
laps shall be .minimum 3-inch, and. end -laps minimum 6-inch wide, .and off .set end -laps
minimum .3 feet from nurse to course., Side and .end -laps. shall. be fully heat -welded and.
inspe.cted,to ensure minimum 3/8'in.ch flow.of modified compound beyond. the I,ap edge.. ,
6:7 : .. Tile Staging:
6.7.1. Tile shall be loaded 8 n4l staged. in a manner that prevents tile slippage and/or damage to the
underlayment.. Refer to Polyglass published requirements for tile staging..
6.7.2 Battens and/or Counte =battens, as required by the the manufacturer and FRSA/TRI 07320/8-
05 must be .used on. II roof slopes greater than 7:12. . Precautions should' be. taken as .
needed,. such as the .0 a of battens or nail -boards, to prevent tile sliding and/or damage to
the underlayment during the loading process.
6.7..3 For nail --on. tile system ..over Polystick MTS, battens are required for loading. / stagin.g 'of .the
tile:
6.7.4 The minimum cure time afterinstallation of self -adhering membranes and before .loading of
roofing. tiles is forty=eig ht (48),hours.
7. LABELING:
Each unit shall bear a'permanent label with ,the manufacturer's, name, logos city,, state and logo of the.
Accredited.Quality Assurance Agency noted herein.
S. BUILDING PERMIT REQUIREMENTS:
As 'required, by the 'Building Offi c ial or Authority Having Jurisdiction in order to properly evaluate the
Installation of this•product:
9.. MANUFACTURING PLANTS:
Contact :the noted .QA: agency for information_ on product, locations covered for F.A.C.. Rule ,9N.-3 QA
requirements.
10.. QUALITY,ASSURANCE' ENTITY:
UL,- LLC QUA9625; (314) 578-3406; k.chancellor@us:ul.corn
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation• Report P12060.02.09-R12
-certificate of Authorization #9563 FL5259-R17
Revision 12: 12/07/2012
Page 10 of 10