Loading...
HomeMy WebLinkAbout1303-0120- PRODUCT APPROVAL ROOFING UNDERLAYMENTFlorida Building Code Online Page 1 of 2 BY Business & Professional Regulation r Florida Departments eCiS Home I Login I User Registration I IHot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search I Busines *USER: Product Approval Professi I Public User Regulation Product Approval Menu > Product or Apol FL # Application Type Code Version Application Status Comments Archived. Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory. Compliance Method Florida Engineer or Architect Name developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expirat Validated By Certificate of Independence Referenced Standard and Year (of > Application List > Application Deta FL5259-R17 Revision 2010 Approved C POLYGLASS USA 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext242. jakins@polyglass.com James Akins jakins@polyglass.com Steve Wadding 150 Lyon Drive Fernley, NV 98408 (602)363-7139 stevew@polyglass.com James Akins 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800) 894-4563 jakins@polyglass.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑✓ Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 UL LLC Date 08/08/2015 John W. Knezeyich, PE 0 Validation Checklist - Hardcopy Received FL5259 R17 COI Trinity ERD CI - Nieminen.r)df Standard Year ASTM D1970 2001 ASTM D226 2006 ASTM D6164 2005 http://www.floridabuilding.org/pr/pr_app_, EVXQwtDgvbSgAaZp3 Crk... 3/14/2013 Florida Building Code Online Page 2 of 2 ASTM D6222 2002 ASTM G154 2005 ASTM G155 2005 FM 4474 2004 FRSA/TRI07320 2005 TAS 103 1995 Equivalence of Product Standard_ s Certified By Sections from the Code Product.Approval Method Method 1 Option D Date Submitted 12/07/2012 Date Validated 12/11/2012 Date Pending FBC Approval 12/18/2012 Date Approved 02/04/2013 Summary of Products FL # Model, Number or Description Name 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: Plo FL5259 R17 II er120712FINAL POLYGLASS UNDERLAYMENTS FL5259- R17.Ddf Approved for use outside HVHZ: Yes Verified By: Robert Nieminen PE-59166 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-622.5 Other: 1.) The design pressurd in this Evaluation Reports FL5259 R17 AE er120712FINAL POLYGLASS UNDERLAYMENTS FL5259- R17.odf application relates to one partic�R' ar underlayment system for use uer Created by Independent Third Party: Yes foam -on tile systems. Refer to Section 5.5.2 for other.systems and maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovrioht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instea6, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1), Florida (Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails'provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® M eCheik M. Credit SArFE http://www.floridabuilding.org/pr/pr_app�dtl.aspx?paratn=wGEVXQwtDgvbSgAaZp3 Crk... 3/14/2013 ot EVALUATION REPORT Polyglass USA, Inc: 150- Lyon Drive Fernley, NV 98408 SCOPE: This Evaluation Report -is issued und( the use of construction materials in reviewed,.by Robert Nieminen, P:E. Florida Building .Code; Residential VI comply with the.2010 Florida Buildin DESCRIPTION.: Polyglass Roof Undl EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 . CHRISTIAN STREET,_UNIT.#13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243' Evaluation Report_ 1312060.02.09-1112 FL5259-R17 Date of Issuance: 02/24/2009 Revision 12: 12/07/2012 Rule 9N-3 and the applicable rules and regulations governing :he State of Florida. The -documentation submitted has been br use of the,'product under:.the Florida Building.:Code and, ume. The products described herein have been designed to Code sections noted herein. LABELING:. Each 'unit shall bear labeling in accordance with the requirements the Accredited. Quality Assurance Agency noted herein. - CONTINUED 'COMP.LIANCE:. This EValu tion Report is valid until such time as the, named.'product(s) changes, the referenced Quality Assurance documentation changesj or provisions,o ,the. Code that relate to the 'product change. Accept#ance.of this- Evaluation Report by the named client constitutes agreement to. notify Robert Niemi.en; P.E. if the product. changes or the referenced Quality Assurance, documentation changes. Trinity[ERD requires a complete review of this Evaluation Report relative to..updated Code requ rements with each Code Cycle: ADVERTISEMENT:.The'Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature If any portion of the Evaluation Report is. displayed,. then it shall be done in .its entirety. INSPECTION::: Upon request, a copy of this entire Evaluation Report shall be .provided to the userby' the manufacturer- or its distributors and shall be available for inspection at thejob job site at . the request of the Building Official.. This Evaluation Report consists of pages 1 through 10. Prepared by: RobertJ.M., Nieminen, P.E. Florida Registration No. 59166, Florida DCA All CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor._does it intent distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled 3. - Robert Nieminen, P.E. does not have nor will act the evaluation reports are being issued. . 4. Robert Nieminen, P.E. does not have, nor will product. 6° +' The facsimile seal appearing was authorized by Robert Nieminen, P.E: on 12/07/2012 • ;' p�,•^�, , ,; .,c f M1 ; . This does not serve as an electrohlcally signed • 3„ document. Signed, sealed hardcopies have been E1983 �'�S'o�rJ�q��.k. ; transmitted. to the Product Approval Administrator and 4�.JJi�rn��'n to the named client to acquire .or will it acquire, a financial interest in any company manufacturing or by any company manufacturing or distributing products it evaluates. uire, a financial interest in any company manufacturing or distributing products for which acquire,- a financial interest in any other entity involved in the approval process of the ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underla Compliance Statement: . Roi demonstrated. compliance with th accordance with the following Sta Limitations / Conditions of Use set 2. STANDARDS: �l l'RINIIY ERD: anent if Underlayments, as produced by Polyglass USA, Inc., have following sections of the Florida Building Code through testing in idards. Compliance is subject to the Installation Requirements and forth herein. Section Property Standard Year 1507.2.3, 1507.3.3, 1507.5.3,. 1507:7.3,=1507.8.3, 1507.9.3 Phy�ical Properties ASTM D226 .2006 1.507.2.4, 1507.2.9.2, 1507.3.3, 1507.5.3 Physical Properties ASTM D1970 2001 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 1504.6 Accelerated Weathering ASTM G154 2005 1504.6 Acc lerated Weathering ASTM G155 2005 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Instpllation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES' Entity Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRIO1111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physlical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) . Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003. PRI (TST 5878) Phy ical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Phy ical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878). Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) _ Phy ical Properties, PUSA-055-02-02 12/10/2007 PRI (TST 5878) Phy ical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Phy ical Properties PUSA-076-02-01 02/22/2008. PRI (TST 5878) Phy ical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Phy ical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) ERD 6049) Physical Properties Win Uplift 11752.09.99-1 11776.06.02 02/08/2000 01/16/2003 (TST ERD (TST 6049) I Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD (TST 6049) Phys cal Properties P11030.11.09-1 11/30/2009 ERD (TST 60491 Wind Uplift - P11030.11.09-2 11/30/2009 ERD (TST 6049) Physical Properties " P11030.11.09-3 11/30/2009 ERD .(TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD (TST 6049) Physical Properties P37300.10.11 10/19/2011 Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1112 Certificate of Authorization #9503 F11-5259-1117 Revision 12: 12/07/2012 Page 2 of 10 TRINITY .ERE � Entity Ex mination Reference Date ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD (TST 6049). Physical Properties C41420.09.12-3 09/11/2012 ICC-ES (EVL 2396) IB G Compliance ESR-1697 11/01/2011 Miami -Dade (CER 1592) HV Z Compliance NOA Current Polyglass USA Ma iufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Ma erials Affidavit Polystick SA Compound 08/18/2011 UL, LLC. (QUA9625) Qu�lity Control Service Confirmation Exp..08/08/2015 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlavments: 4.1:1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a. polyesterreinforced, SBS modified bitumen base sheet. 4.2 Self-Adherina Underlayments: 4.2.1 Polystick MTS is 'a nominall60-mil thick rubberized asphalt waterproofing membrane; glass fiber reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103. 4.2.2 Polystick IR-Xe is a norm al 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU is a nominal i00-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.4 iPolystickTU Plus is a no inal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane,. glass- fiber/polyester reinforced With a granular surface; meets ASTM D1970. and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 170 g/m2 polyester fabric surface; meets TAS 10.3. 4.2.7 Polyflex SAP, PolyFlex, SAPS FR, Mule -Hide SA-APP Cap Sheet a'nd Mule -Hide SA-APP Cap Sheet (FR) are a polyester reinforced, APP modified bitumen cap sheets. 4.2.8 Dual ProTM is a nominal 6i0-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.2.9 Tile PrOTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with apolyester fabric surface. 4.3 Mechanically Fastened aI d/or Bonded Underlavments: 4.3.1 Elastoflex S6 G and Ela sheets. 4.3.2 Polyflex G and Polyflex G S. LIMITATIONS: 5.1 This Evaluation Report is S6 G FR are polyester reinforced, SBS modified bitumen cap are polyester reinforced, APP modified bitumen cap'sheets. for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory. for fire ratings of this product. Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report P12060.02.09-11112 FL5259-R17 Revision 12: 12/07/2012 Page 3 of 10 5.3 Polyglass Roof Underlay specifically referenced v to the AHJ for approvi prepared roof covering. O �l 1' RINITY IfRp. ents may be used with any prepared roof cover where the product is hin FBC approval documents. If not listed, a request may be made based on this evaluation combined with supporting data for the S a AIlnwnhie rnnf rnverc nnnlieri atnn the itnrlerlavments are as fnllnwc- Table 1: Roof Cover Options Underlayment Asphal Nail -On Tile Foam -On Metal Wood Shakes & Slate Shingle Tile Shingles Elastobase Yes Yes No Yes Yes _ Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MTS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU Yes Yes es No Yes Yes See 5.Polystick TU P Yes I Yes es No Yes' Yes See 5.Polystick TU Plus Yes Yes es Yes Yes Yes See 5.Yes Polystick TU Max No Yes No No No See 5.4.1 Dual Pro. Yes Yes No Yes Yes Yes Tile Pro Yes Yes Yes Yes Yes Yes 1 See 5.4.1 Elastoflex S6 G Yes Yes es No Yes Yes See 5.Elastoflex S6 G FR Yes Yes No No Yes Yes Polyflex G Yes Yes es No Yes Yes See 5.Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes See 554.1 Ye No Yes Yes Mule -Hide SA-APP Cap Sheet Yes I Yes Yes No Yes Yes or SA-APP Cap Sheet (FR) See 5.4.1 5.4.1 "Foam -On Tile" is limiter adhesion / long term agin, ➢ Polyfoam PolyPro A G, Polyflex G, Polyflex SA-APP Cap. Sheet (FR ➢ 3M11" 2-Component I ➢ Dow TileBond: Polys ➢ Convenience Produc Plus, Polystick TU Max 5.4.2 For nail -on the systems o tile. 5.4.3 A 2-ply underlayment Sys P, TU Plus or TU Max, c prepared roof systems. system is desired. Exterior Research and Design, LLC. Certificate of Authorization #9503 to use of the following Approved tile adhesives unless tensile data from an accredited testing laboratory is provided. 160: Polystick TU, Polystick TU P, Polystick TU Plus, Elastoflex S6 AP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide or Tile Pro. oof Tile Adhesive AH-160: Polystick TU Max ck TU P, Polystick TU Plus, Pol'yflex SAP or"Tile Pro a' Touch 1n Seal StormBond Roof Tile Adhesive: Polystick TU r Polystick MTS, battens are required for loading / staging of the m, consisting of Polystick MTS followed by Polystick MTS, TU, TU Polyflex SAP is allowable for use under mechanically attached is is not a requirement, but is allowable if a 2-ply underlayment Evaluation Report P12060.02.09-1112 FL5259-R17 Revision 12: 12/07/2012 Page 4 of 10 TRINl , ,Y ERQ, 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: Polystick, Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self-adh red to:. ➢ New untreated plywood ➢ ASTM D41 primed new I ntreated plywood;. ➢ Existing plywood;. ➢ ASTM D41 primed existi • g plywood; ➢ ASTM D41 primed OSB; . ➢ Southern Yellow Pine ➢ ASTM D41 primed Sout ern Yellow Pine; ➢ ASTM D41 primed struc ural concrete; ➢ .Huber Engineered Wood 'ZIP System".Panels (designed and installed. to meet wind loads for project). Note: Polyglass does n t require priming of new or existing plywood sheathing. New or existing. plywood sheat ing should be cleaned :of all dirt and debris prior to application of Polystick membranes. Elastoflex S6-G or S6 G II R in hot asphalt to: ➢ ASTM D41 primed structLral concrete. Polyflex G or.(jFR torch applied to: ➢ ASTM D41 primed structtral concrete. 5.5.2 Wind Resistance for Unc does not address wind systems, where the unc limitations apply'to unde used in'foam-on.tile ap-p load resistance based or design wind- pressures. rlavment Systems in Foam -On Tile Applications: FRSA/TRI 07320 )lift resistance of all underlayment systems beneath foam -on tile rlayment forms part of the load -path.. The following wind uplift ayment systems that are not addressed in FRSA/TRI 07320.and are: rations. Maximum Design Pressure is the result of. testing -for wind allowable wind loads. Refer to FBC.1609:1.5 for determination of- 5.5.2.1 Maximum-Desian Pressurle = -622:5 qsf. Deck: _ Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM .D 1 Underlayment: Elastofle S6 G, applied in full mopping of hot asphalt or Polyflex G, torch - applied.: . 5.5.2.2 Maximum Design Pressure = -315 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer:: ASTM D 11 5.5.2.3 Underlayment: Polystick TU; Polystick TU P, Polystick TU Plus, .Polystick. TU Max, Tile Pro, . Polyflex AP,.PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR). Maximum Desian Pressur8 = -135 psf. Deck:. Min. 15/i2-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optionally ASTM D41 Joints: Min. 4-inch wide strips -of Elastoflex SAN over all plywood joints. Underlayment: Polystick. U; Polystick.TU P, Polystick TU Plus, Polyflex SAP,. P.olyF.lex'SAP FR, Mule-Hide Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R12 Certifcate of Authorization #9503 FL5259-R17 Revision 12: 12/07/2012 Page 5 of 10 �I TRIMTY � ERa 5.5.2.4 Deck:. Min. 15%32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Underlayment: Polystick TU, Polystick TO P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) 5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on the systems carry a Maximum Desig Pressure of -45 psf. 5.5.3 Bond -to -Insulation: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: AI�STM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite' insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum- fiber Roof Board. ➢ Elastoflex S6 G or S6'G FR in hot asphalt•to: DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck Prime or SECUROCK Gypsum -Fiber Roof.Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualit�ed design professional and installed based on testing of the insulation/underlayment systemin accordance with .FM 4470, Appendix K or TAS 114, Appendix J. 5.5.4 Bond to Mechanically Attached Base Laver: 5.6 5.6.1 5.6.2 5.6.3 5.6.4 5.6.5 ➢ Polystick; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Elastoflex S6 G or S6 G FR in hot asphalt to: ASTM D226, Type I or II felt, Elastobase; Elastobase P or Mule Hide Nail Base. ➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be atta hed per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. Exposure Limitations: Elastobase, Elastobase P, shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe, Polystick TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 90-days after installation.. Polystick MTS, TU, TU p or TU Plus shall not be left exposed for longer than 180-days after installation. 'Polyflex SAP or SAP FRS or Mule -Hide SA-APP Cap Sheet or SA=APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which ,case the maximum exposure is 30 days. Elastoflex S6 G or S6 � FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G), in which case the maximum exposure is 180 days. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-11112 Certificate of Authorization #9503 FL5259-R17 Revision 12: 12/07/2012 Page 6 of 10 I EftD 5.7 For tile. roof installatior s governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited o the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of 02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems. Table 3: Tile System Options per FRSA/TRI.07320/8-05 System Underlay Section) Reference Product(s) Option 3.02A 1 Batten Modified Cap Sheet Elastoflex S6 G or Elastoflex S6 G FR; Polyflex G'or G FR only No. 30/'Modified Cap Base Layer: Elastobase; Elastobase P System One: 2 3.02B Sheet Top Layer: Elastoflex S6 G or Elastoflex S6 G FR; Polyflex G or G Mechanically FR Fastened Tile, 4 3.02D No. 30 Elastobase; Elastobase P Unsealed or: Self -Adhered Polystick MTS; TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP Sealed " 5 3.02E Underlayment FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Underlayment Dual Pro; Tile Pro System Base Layer:,ASTM D226, Type II; Elastobase; Elastobase P; , No. 30 / Self -Adhered Mule -Hide Nail Base 6 3.02F Underlayment Top Layer: Polystick MTS; TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual Pro; Tile Pro 3.62A 1 Batten Modified Cap Sheet Elastoflex S6 G or Elastoflex S6 G FR; Polyflex G or G FR only No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P System Two: 2 3.02E Sheet Top Layer: Elastoflex S6 G or Elastoflex S6 G FR; Polyflex G or G Mechanically . FR Self -Adhered Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or'SAP FR; Fastened Tile, Sealed 4 3.02D Underlayment Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual Underlayment Pro; Tile Pro System Base Layer: ASTM D226; Type II; Elastobase; Elastobase P; No. 30 / Self -Adhered Mule -Hide. Nail Base 5 3.02E Underlayment Top Layer: Polystick TU; TU P; TU Plus; TU Max;. Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro; Tile Pro,. 1 3.02A Modified Cap Sheet Elastoflex S6 G or Polyflex G 2 3.02B I No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P System Four "A": Sheet Top Layer: Elastoflex S6 G or Polyflex G Adhesive -Set Tile, 4 3 I Self -Adhered Polystick TU; TU P; TU Plus; TU Max; ,Polyflex SAP or SAP FR; Unsealed or .02D Underlayment Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Sealed Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; Underlayment . Mule -Hide Nail Base System 5 3.02E No. 30 / Self -Adhered Underlayment, Top Layer: Polystick TU; TU. P; TU Plus; TU Max; .Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) 1 3.02A No. 30 / Modified Cap Base'Layer: ASTM D226, Type II; Elastobase; Elastobase P . Sheet Top Layer: Elastoflex S6 G or Polyflex G System Four "B": 3 3.02C Self -Adhered Underlayment Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP.Cap Sheet (FR) Adhesive -Set Tile, Sealed Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; Underlayment Mule -Hide Nail Base System 4 3.02D No. 30 / Self -Adhered Underlayment Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1112 Certificate of Authorization #9503 FL5259-R17 Revision i2: 12/07/2012 Page, 7 of 10 6. INSTALLATION: 6.1 Polyglass Roof Underli installation requiremen specifics noted below. 6.2 Re -fasten any loose c substrate thoroughly b substrate (if.applicable) 6.3 Elastobase, Elastobas 6.3.1 Shall be installed. in cc underlayment in FBC Se 6.3.2 For use in non -tile appli( 6.3.2.1 Reference is made to tl- recommendations for in: 6.3.2.2 Elastobase, Elastobase Polyflex SAP or SAP FR, Tile Pro; self -adhered, E applied. 6.3.3 For use in tile. applicatio conjunction with FRSA, herein. 6.4 PolYstick MTS, IR-Xe, nQ �I I! RINITY I ERp �ments shall be installed in accordance with Polyglass published s subject to the Limitations set forth in Section 5 herein and the ,king panels, and check ,for protruding .nail heads. Sweepthe remove any dust and debris prior to application., and prime the mpliance with the codified requirements for ASTM D226, Type II :tions 1507 for the type of prepared roof covering to be installed. Awl current edition of the NRCA Steep -slope Roofing Manual and ARMA Iling shingle underlayments and flashings or Mule -Hide Nail Base may be coveredwith a. layer of Polystick, ule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or stoflex S6 G or S6 G FR in hot asphalt or .Polyflex G or G FR, torch reference is made to Polyglass published installation instructions in 1 07320/8-05 Installation Manual, Fourth Edition, and .Table 2 6.4.1 Shall be installed in combliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 forlthe type of prepared roof covering to be installed. 6.4.2 For non -tile applications: 6.4.2.1 All self -adhering materiz and Mule -Hide SA-APP C edge seam in accordan corrosion resistant, 11 g Simplex -type metal cap nailed using the above clavar" on the face of m nailed 6.4.2.2 All seal -lap seams (selvz ensure full contact and a the end of the -glue patte Exterior Research and Design, LLC. Certificate of Authorization #9503 Is, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR 3p Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage :e with Polyglass / Mule -Hide Back Nailing Guider Nails shall be iuge ring -shank type.with a minimum 1-inch diameter metal_ disk or sail, at a minimum rate of 12" o.c. Polystick TU Plus should be back- ioted fasteners and spacing, in area marked "nail area, area para :mbrane. The head lap membrane- isto cover the area being back - laps) must be firmly rolled with a minimum 28 lb. hand roller to esion. For Dual Pro and Tile Pro, align the edge of the top sheet to (the sheet will overlap the fabric). Evaluation Report P12060.02:09-1132 FL5259-R17 Revision 12: 12/07/2012 Page 8 of 10 . TRINITY ;ERD View of Ovelap Seam of JDual Pro and Tile Pro 6.4.2.3 All over -fabric and ove9ranule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG5 1.0 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241tement, Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing or, Mule -Hide 421 Mod Bit .Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap: 6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details 6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flash, ing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flasshing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a minimum: 6 x 6 inch patch of the Polystick material of like.kind,.seli and hand .rolled in place. over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. 6.4.2.6 All Polystick membranes shall be installed to ensure full .contact with approved. substrates. Polyglass. requires, a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of _load applied for the field membrane. Hand rollers are acceptable for rolling of 'Patches,. laps (min. 28 lb'roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 For tile applications (not allowed for Polystick IR-Xe): 6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 6.5 Elastoflex S6 G or S6 G FR: 6.5.1 Elastoflex S6 G or S6 G FR shall be installed 'incompliance with current Polyglass published installation requirements. For use in tile applications,. reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1112 Certificate of Authorization #9503 FL5259-1117 Revision 12: 12/07/2012 Page 9 of 10 6:5:2 Elastoflex S6 G or-S6 FR shall be fully asphalt -applied to the..substrates.noted.in Section .5.5, Side laps'shall be minimum- 3-inch and end -laps minimum 6-inch wide, and offset end laps minimum 3 feet'f om course to course. .Side and end laps shall be fully adhered in a complete mopping of: of asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 - Polvflex G or G FR: 6.6.1 Polyflex,G or G'FR shall be installed incompliance with current Polyglass published installation requirements.. For se _ in tile applications, reference is made FRSA/TRI .07320/8-05. Installation Manual, Fo rth Edition,, and Table•2 herein. . 6.6.2 'Polyflex G or G FR she II be fully_ torch -applied. to.the substrates noted in Section 5.5. Side• laps shall be .minimum 3-inch, and. end -laps minimum 6-inch wide, .and off .set end -laps minimum .3 feet from nurse to course., Side and .end -laps. shall. be fully heat -welded and. inspe.cted,to ensure minimum 3/8'in.ch flow.of modified compound beyond. the I,ap edge.. , 6:7 : .. Tile Staging: 6.7.1. Tile shall be loaded 8 n4l staged. in a manner that prevents tile slippage and/or damage to the underlayment.. Refer to Polyglass published requirements for tile staging.. 6.7.2 Battens and/or Counte =battens, as required by the the manufacturer and FRSA/TRI 07320/8- 05 must be .used on. II roof slopes greater than 7:12. . Precautions should' be. taken as . needed,. such as the .0 a of battens or nail -boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7..3 For nail --on. tile system ..over Polystick MTS, battens are required for loading. / stagin.g 'of .the tile: 6.7.4 The minimum cure time afterinstallation of self -adhering membranes and before .loading of roofing. tiles is forty=eig ht (48),hours. 7. LABELING: Each unit shall bear a'permanent label with ,the manufacturer's, name, logos city,, state and logo of the. Accredited.Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As 'required, by the 'Building Offi c ial or Authority Having Jurisdiction in order to properly evaluate the Installation of this•product: 9.. MANUFACTURING PLANTS: Contact :the noted .QA: agency for information_ on product, locations covered for F.A.C.. Rule ,9N.-3 QA requirements. 10.. QUALITY,ASSURANCE' ENTITY: UL,- LLC QUA9625; (314) 578-3406; k.chancellor@us:ul.corn - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation• Report P12060.02.09-R12 -certificate of Authorization #9563 FL5259-R17 Revision 12: 12/07/2012 Page 10 of 10