Loading...
HomeMy WebLinkAboutPOOL SPECIFICATIONS12° x 12° concrete w/ 2 El BY N ��" St LucieCOW* i i SCALE: 1/8" = V Pool Size: 16' x 32' Depth: 3`6" to 5'6" to 4' Area: 450 sq. ft. Perimeter: 90' Gallons: 13,500 Coping: Over pour Filter: Cartridge Pump: Pentair Variable speed, Pentair Whisperflow 2 speed Lights: 2- LED Pool Coating: Gem Stone Model 012530 Deck type: Spray deck Area: 1,680 sq ft Drain: Deck o drain Automatic Cleaner line Sun shelf Conversation pit with table - I XWO \) d 1 Install pool/spa per ANSI 3,5,7,15 an6 0VV Pool patio and equipment to be In accordance with FBC 2017 code chapter 64E-9 FAC and requirements of FBC Ch 4,454 All bonding and electrical noted on a separate sheet. To be current with all codes Adams Consulting & Design Inc. SORS dan el'78@ ail.com Y I � Designed for: Rinker Residence � , T. E. S C H LITr 12805 79th St Phone: 772 519 0772 11735 Appaloosa Ct. — � � TERE CE�SCHLITT, PE;81238 — ATE Fellsmere,Florida 32948 SurfsideRocksca es p Fax: 772 4612786 Port saint Lucie, Fl. 34987 ENGINEERING, LLC.-.1555, INDIAN RIVER BLVD, SUITE B-145 CA#322ss VERO BEACH,. FL. 32960` PH:772-360-4998 RP 252554858 11:;7RL9CTURAFLGGMAILMM 14 NFORfAMN01E NODMNGBOMANDNOL&WSAMMNAW ronLtH MA!-CrMw nrn5alnNuMG0F RWM7F6PO0LSWrDM0R)RDVlNG I 2' .I 36° L(11RavoNIT71E �t>F n. 6°NwRDot • THONG s»_ NY•eE"TNAOff WWWRSERW LONGITUDINAL POOL SECnON NOTE: OUTSIDE ANGLE OF REPOSE-0"-- 6'AND FURTHER = 4" THICK WALLS W/ #TS • @ 12" O.C. EA. WAY to `;� 3'-5,= " 5" TO 6" THICK WALLS W/ ADDT'L • oti='� #3's @ 12" O.C. EA. WAY 0'-3"= 6" TO 8" THICK WALLS W/ ADD7'L #3' s @ 1211 O.C. EA. WAY ANGLE OF REPOSE Ye Return ee ball 2° 4 Return piping VGB series 32" Channel Drain 2u To Pump Max flow B' per sec. Dom Single Channel dual outlet RexegWaL Per FRC41OL6.6 POOL MAIN DRAIN DETAIL 'EitlsraNG Sloe REsroENr£ .a, 4 4 4L ANGIEoF REP051: Flow and Friction Loss Per Foot Schedule 40 P.V.0 Velocity - Feet Per Second Pipe Size g fpc 10 fps 1" 21 gpm 0.23' 26 gpm 0.35' 1.5" 50 gpm 0.14i 62 gpm 0.21' 2" 82 gpm 0.10' 103 gpm 0.16' 2.5" 117 gpm 0.09' 146 gpm 0.13' 3" 181 gpm 0.07' 227 gpm 0.10' 4" 313 gpm 0.05' 392 gpm 0.07' 6" 712 gpm 0.03' 0#1sDutt xWS 1brasaea2°x4° UP10 6@11or RezegWai Tom ' I r' ftONG RESIDENCESLAS p > >V a•• u LWaL pG as 4 d,g Fowl A a'' ' W rx4°x1TNatrero B<QIFCF oiat%% Co�,ENus 09 P&MODSHMIN G SHORING DETAIL To be Installed on the filter pump for a final inspection Pressure guage l T' Vacuum guage Co D SAE GME&WeL RNrPotGRma MNNDIM& ArMALI(PLUP ToWiLOWLNe RCFD%GMRN1 ME Mro HvniaolM Sib -1' S'NURnw lltua tas@lra 11-WN (atRnsovete-a' RESIDENTIAL SWIMMING POOL NOTES . 5'TxacwxL �AmiBOa,EBga @1racASSVW 1. CONSTRUCTION SHALL COMPLY WITH FBC 2017, ANSI 7, AND ANSI-15. Raw= ;�` 2- PLOT PLANS NOT PREPARED FROM LEGAL SURVEYS OF EXISTING LOT AND RESIDENCE. POOL VASE •.rr CONTRACTOR/OWNER SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES IF a, NECESSARY PRIOR TO CONSTRUCTION. <igl 3. CONTRACTOR/OWNER SHALL LOCATE ALL UTILITIES AT THE SITE AND MAINTAIN MINIMUM CLEARANCES G - PER CODE. CALL 811 BEFORE CONSTRUCTION BEGINS. Nam IIDwmMAxWA1LSlOPE(TVP) Typical Wall & FloorSection / Well Point Pool one pump System Pool equipment to be bolted per maufacures specs. • = bolts Filtration pump R�IEfwR� • > > A w/M3a v C • .B PIPE LENGTH To 9E 4 x PIPE Dtti E A1°` 4. POOL DECK SHALL BE CONSTRUCTED OF CONCRETE OR OTHER NONABSORBENT MATERIAL PAr > > HAVING A SLIP RESISTANCE FINISH AND SHALL BE UNIFORMLY SLOPED TO PREVENT STANDING WATER. 5. POOL DECK SHALL HAVE A MINIMUM PITCH OF THREE INCHES IN TEN FEET AWAY FROM POOL OR TOWARDS THE DRAINS. SLOPE SHALL NOT EXCEED 1:20 UNLESS NOTED PER PLAN. 6. FOUNDATION SHALL PROVIDE A SAFE BEARING CAPACITY OF 1200 PSF MINIMUM. ORGANICS, MUCK, OR OTHER TYPES OF DELETERIOUS MATERIALS ENCOUNTERED UPON EXCAVATION SHALL BE REMOVED AND THE AREA BACKFILLED WITH WELL GRADED GRANULAR FILL AND COMPACTED IN 12 INCH LIFTS. It WEAK SOILS CANNOT BE REMOVED, POOL SHALL BE DESIGNED AND BUILT ON PILING SYSTEM WITH STRUCTURAL SHELL. 7. CONTRACTOR SHALL BACKFILL THE POOL SHELL WITH CAUTION AND WITHOUT DISTURBING. THE PLUMBING. BACKFLL MATERIAL SHALL BE CLEAN SAND, FREE OF ORGANICS AND PLACED IN 12 INCH LIFTS. EACH LAYER SHALL BE COMPACTED TO 987oDENSITY BY TAMPING SOLIDLY. SOILS BENEATH THE PATIO SHALL BE COMPACTED SIMILARLY. POOL BACK FILL SHALL BE TESTED BY A SOIL ENGINEER 8. WATER VELOCITY -MAX 8FT/SEC AS PER FBC-R 4501. 9. POOL BARRIER SHALL COMPLY WITH FBC-R 4501. 10. EQUIPMENT FOUNDATION PAD SHALL BE MIN. 4" THICK 3'x7 3,000 PSI CONCRETE SLAB OVER WELL COMPACTED GRADE. 11. WATER EQUIPMENT SHALL COMPLY WITH FBC-R 4501 AND SKIMMERS SHALL COMPLY WITH FBC-R 45D1.21 12. ALL STEPS, SHELF, AND SWIMOUT BENCH EDGES SHALL HAVE A 'TILEBORDER• OF QPPOSFTEr COLOR OF GEM FINISH FOR VISIBILITY. 13. ALL STEPS AND SWIMOUTS SHALL BE SOLID GUNITE, ALL GUNITE SHALL BE 3,000 PSI MINIMUM A-Raraual P" 14. SHELL BELOW COPING EDGE SHALL HAVE ONE 05 BAR OR TWO 03'S CONTINUOUS. B-Hw&tNrSwm 15. HANDHOLDS SHALL BE INSTALLED AT POOL EDGE WHERE BOTH THE DECK IS GREATER THAN 6" ABOVE c-R70LlW?PWRjE4C*M&A" DFiaoat SURFACE OF WATER AND WHERE THE DEPTH OF POOL EXCEEDS 4 FT. LOCATE NO GREATER THAN 4 FT E-otah= ON CENTER AND 9" ABOVE WATERLINE, 16. TRENCH DRAIN COVER(S) SHALL BE SECURED IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL I�niNO"VP"E�7g11' Ujm 17. POOL WALLS SHALL NOT SLOPE GREATER THAN 11 DEGREES. 18. FLOOR SLOPES SHALL BE_REASONABLY_UNMORMA_ NO SHALL_CQMP_LY_WITH_ARTICLES_5.6.1_THRU_5.6.3. ++WAN 19. _ SLOPE OF POOL FLOOR SHALL NOT EXCEED THE FOLLOWING AMOUNTS: SHALLOW END TOWARDS -►•��J DEEP AREA: 1 VERTICAL IN 7 HORIZONTAL, DEEP END:1 VERTICAL IN 3 HORIZONTAL. 20 PRESSURE GAUGES (SEE DETAIL) SHALL BE INSTALLED ON FlLT PUNT 2011 VGB Pool Entrapment Requirements APSP-5 and 7 Determine System Flow Rate: Minimum Flow Rate Required: 35 gpm per skimmer 1. Calculate Pool Volume: _15 avg- x _32_ Ft_4-x 7.48 (gal/ Ft) = _13,500_gal_ (Surface Area) (Average Depth) (Volume in gallons) 2. Determine Flow Rate: _13,500. gal_ / _374_ = _36 gpm_ + = 36 gpm_ (Volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rate) (System Flow Rate) Determine Pipe Sizes: Trunk Piping to be _2"_ inch to keep velocity @ 8 fps max. at _82_ gpm Maximum System Flow Rate. Return Piping to be _2"_ inch to keep velocity @8 fps max. at._82_ gpm Maximum System Flow Rate. Patio to be 4" thick w/ fiber mesh 2011 Pool Pump / Energy Efficiency Requirements APSP-15 Pool Pump Controller. Time Clack Set to run daily @ 36 gpm for 374 Min. to achieve one complete turn over In less than 12 hrs max. Minium run time of 374 mine.13,500 gal. / 36gpm = 374 min. Pool Filter 13,500 3746 min. 1.375 = 96 filler's min sq. ft. i Pump selection: (StaRite % h.p. 2 spd) using TDH & Calculator ( see attached form) Pentair WhisperPlow 2 speed Model 012530 ER P FOR FINAL INSPECTION. 21. HYDRO -STATIC RELIEF DEVICE INSTALLED IN AREAS THAT EXCEED 1 FT WATER TABLE IN SHELL. 22. LIFE SAFETY: A BARRIER OR ALARM IS NOT A SUBSTITUTE FOR RESPONSIBLE SUPERVISION. NO CHILD SHOULD BE LEFT UNATTENDED. THE POOL DESIGNER CANNOT BE HELD RESPONSIBLE FOR ANY LOSS, DAMAGE, DEATH, OR INJURY DUE TO MALFUNCTION OR FAILURE OF A BARRIER OR ALARM. .Nr,�'` JUG' JYt`��u ®C� Install pool/spa perANSI 3,5,7,15 and 16 Pool patio and equipment to be in accordance with FBC 2017 code chapter 64E-9 FAC and requirements of FBC Ch 4,454 All bonding and electrical noted on a separate sheet. To be current with all codes Adams Consulting & Design, Inc. danyelj78@gmail.com Designed for: Rinker Residence 79th StreetS--)R�sPhone: 772 519 0772 ' , T.E. SCHLITT12805 S 3 Fellsmere„Florida 32948 SurfsideRockscapes Fax: 772 4612786 11735 Appaloosa Ct. Port saint Lucie, Fl. 34987 TEREN SCHLITT,PE8123B DATE ENGINEERING,LLC. 1655 INDIAN RIVER BLVD, SUITE B-145 CAP32295 VERO BEACH, FL.32960 PH:772-36o.499B RP 252554858 STRUCTURAFL GMAIL.COM Florida Statute (F.S.) 471.003 exempts electrical contractors licensed in the State of Florida from having to be licensed as a STAINLESS STEEL Professional Engineer when performing HANDRAIL design of a residential electrical system less SAME BONDING FOR than 600 amperes. Specifically: LADDER) 471.003(2) The following -persons are not required to be licensed under the provisions of this chapter as a licensed engineer: (h) Any electrical, plumbing, air- •••.••.•.w,` )R W/ #8 BOND conditioning, or mechanical contractor &APPR BOND whose practice includes the design and CLAMP fabrication of electrical, plumbing, air- 3OND WIRE PPR CLAMP Electrical Equipment Wiring, Grounding and Installation must conform to the FBC 2017 N.E.C. and applicable local codes SERVICE PANEL W/P DISCONNECT W/P G.F.I NOTE: WATER-PRooF G.F.I. Musr NOT BE MORE THAN20'-0"FROM PSAND Noo 30' - 0" OF P E 0 12VIJGHT TRANSFORMER W/P DISCONNECT 3# 8IN W CONDUIT <IFA HEATER IS INCLUDED POOL TUBER W/ • S.P. -S.T. TOGGLE -SWITCH 3 #12IN Pool Heater NMALLEUMC4VWCWSMUC&MWToNECARMWNo6W ELECTRICAL DIAGRAM conditioning, or mechanical systems, respectively, which she or he installs by virtue of a license issued under chapter 489, under !part I of chapter 553, or under any special act or ordinance when working on any construction project which: 2.a. Requires an aggregate service capacity of 600 amperes (240 volts) or less on a residential electrical system or 800 amperes (240 volts) or less on a commercial or industrial electrical system; 18" MIN. - 24" MAR ENTIRE PERIMETER #8 SOLID BARE COPPER BOND WIRE W/ APPR. CLAMPS (ONE ON EACH SIDE OF POOL — 4 TOTAL) 4" TO 6" BELOW SUB- GRADE 1- #8 BARE COPPER WIRE BONDED TO POOL STEEL AS SHOWN NOTE: BONDING GRID REQUIRED AT PERIMETER OF POOL IN AREAS OF PAVED DECKING ONLY EQUIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTATION OF THE N.E.C. 2017 SEC.680.26 Equipotential Bonding —OPTIONAL2-UG Loop #8 copper around Pool Bonded to pool steel in 4 Places N.E.C. 2017 JUNCTION-BOX(S) sec. 680.26(C) I.B. 1.OF8" J.B. ABOVE POOL DECK Install pool/spa per ANSI3,5,7 and 15 POOL DECK NEGAFeItOvml' _J mccaccir ' �oo��u.��oler@be��soutl�.wet 1>hom: 772 318 8626 RIX: 772 571 8108