HomeMy WebLinkAboutENERGY EFFICIENCY CODE.� FILt
FORM R405-2017 .�
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MW-277
Builder Name:
Street: 3218 BENT PINE DR Permit Office:
City, State, Zip: FORT PIERCE, FL, 34951 ®v
BY
_
Permit Number:
Owner: Jurisdiction:
LUCIE_CO_INTL �t Lucie /Mumtounty:
Design Location: FL, ST l
St. Lucie (Florida Climate Zone 2 )
Im
1. New construction or existing New (Fr Plans)
9. Wall Types (2381.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 2071.40 ftz
b. Frame - Wood, Adjacent
R=11.0 309.78 ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 3
d. N/A
R= ftz
10. Ceiling Types (2284.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2284.00 ftz
6. Conditioned floor area above grade (ftz) 2284
b. N/A
R= ftz '
c. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
11. Ducts
R ftz
7. "Windows(380.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 702
�al U-Factor: Dbl, U=0.62 380.43 ftz
= SHGC: SHGC=0.26
b. U-Factor: N/A ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
48.0 SEER:16.00
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2284.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2284.00 ftz
b. Conservation features
b. N/A R= ftz
None
a c; N/A R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.167 Total Proposed Modified Loads: 73.66
PASS
I Total Baseline Loads: 75.06
�I hereby certify that the as dUificat!red by
Review of the plans ando4ZHE
5rg1this
calculation arein compliant ergy
specifications covered by this
indicates
Code.
calculation
compliancev.with the Florida Energy Code.rnPREPARED
BY:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
i - a
_
I hereby certi)y t t"ttlis wilding, as dee i ned, is in compliance
Code. M
Florida Statutes.
with the Florida Ene�rg
COD WE
f
....OWNER/AGENT
BUILDING OFFICIAL:
DATE: A"-��
DATE:
_
i
Compliance requires certification bylthe air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with en lope leakage no greater than 6.60 ACH50 (11402.4.1.2).
I
1/28/2019 9:48 AM I EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5
k- .
t
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
I PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-277
User
1
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 2284
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
3218 BENT PINE DR
St. Lucie
FORT PIERCE,
FL, 34951
-
I
CLIMATE
/
V Design Location
TMY Site
Design Temp
97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST—LUCIE—CO INTL FL_VERO BEACH
MUNI 39 90
70
75 299
58 Medium
I
BLOCKS
'Number
Name
Area
Volume
1'
Blockl
2284
21241.2
I
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
2284
21241.2 Yes 4
3
1 Yes
Yes Yes
I
FLOORS
#
Floor Type
Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio I Main 209.9 ft 0
2284 ft2
__--
0 0 1
ROOF
/
V; #
Type
Materials
Roof Gable Roof
Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Barrel the
2554 ft2 0 ft2 Medium
0.4
N 0.9
No 0 26.6
ATTIC
V #
Type
Iventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
i Vented 150 2284 ft2
N N
I
CEILING
#
Ceiling Type
I
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2284 ft2 0.1
Wood
I
1/28/2019 9:48 AM I EnergyGauge® USA Section R405.4.1 Compliant Software
Page 2 of 5
Pr)PRA Rangy-2017 INPUT Sl1MM,4RY CHECKLIST REPORT
I
WALLS
Adjacent
Cavity Width Height
Sheathing
Framing Solar
Below
V#-Llrnt
To
Wall -Type _
Space
_flue-Ft-In-Et-ln
Area
R-value-Fraction-Absor-Grade%--
_ 1
N
Exterior
Concrete Block - Ext Insul
Main
4 32
0 11
4
362.7 ft2
0
0 0.3
0
_ 2
E
Exterior
. Concrete Block - Ext Insul
Main
4 55
0 9
4
513.3 ft2
0
0 0.3
0
3
S
Exterior
Concrete Block - Ext Insu�
Main
4 58
2 9
4
542.9 ft2
0
0 0.3
0
_ 4
SW
Exterior
Concrete Block - Ext Insu
Main
4 8
9 11
4
99.2 ft2
0
0 0.3
0
_ 5
W
Exterior
Concrete Block - Ext Ins II
Main
4 55
9 9
4
520.3 ft'
0
0 0.3
0
_ 6
NW
Exterior
Concrete Block - Ext Ins�l
Main
4 2
11 11
4
33.1 ft2
0
0 0.3
0
7
-
Garage
Frame - Wood I
Main
11• 27
4 11
4
309.8 ftz
0
0.25 0.3
0
I
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood Main
None
.39
3
8
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
n 1
Metal Double (Clear)
Yes
0.62 0.26
N
30.0 ft2
0 ft 0 in
0 ft 0 in
None
None
2
n 1
Metal Double (Clear)
Yes
0.62 0.26
N
6.0 ft2
0 ft 0 in
0 ft 0 in
None
None
3
n 1
Metal Double (Clear)
Yes
0.62 0.26
N
8.0 ft2
0 ft 0 in
0 ft 0 in
None
None
4
n 1
Metal Double (Clear)
Yes
0.62 0.26
N
21.7 ft2
0 ft 0 in
0 ft 0 in
None
None
5
e 2
Metal Double (Clear)
Yes
0.62 0.26
N
20.7 ft2
0 ft 0 in
0 ft 0 in
None
None
6
e 2
Metal Double (Clear)
Yes
0.62 0.26
N
43.3 ft2
0 ft 0 in
0 ft 0 in
None
None
7
e 2
Metal Double (Clear)
Yes
0.62 0.26
N
4.5 ft2
0 ft 0 in
0 ft 0 in
None
None
8
s 3
Metal Double (Clear)
Yes
0.62 0.26
N
42.9 ft2
0 ft 0 in
0 ft 0 in
None
None
9
s 3
Metal Double (Clear)
Yes
0.62 0.26
N
96.0 ft2
0 ft 0 in
0 ft 0 in
None
None
10
s 3
Metal Double (Clear)
Yes
0.62 0.26
N
26.0 ft2
0 ft 0 in
0 ft 0 in
None
None
11
s 3
Metal Double (Clear)
Yes
0.62 0.26
N
6.5 ft2
0 ft 0 in
0 ft 0 in
None
None
12
sw 4
Metal Double (Clear)
Yes
0.62 0.26
N
18.7 ft2
0 ft 0 in
0 ft 0 in
None
None
13
sw 4
Metal Double (Clear)
Yes
0.62 0.26
N
18.5 ft2
0 ft 0 in
0 ft 0 in
None
None
14
w 5
Metal Double (Clear)
Yes
0.62 0.26
N
20.7 ft2
0 ft 0 in
0 ft 0 in
None
None
15
w 5
Metal Double (Clear)
Yes
0.62 0.26
N
7.0 ft2
0 ft 0 in
0 ft 0 in
None
None
16
NW 6
Metal Double (Cleary)
Yes
0.62 0.26
N
10.0 ft2
0 ft 0 in
0 ft 0 in
None
None
I
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
686 ft2 686 ft2
1
64 ft
9.3 ft
1
1/28/2019 9:48 AM I EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5
GnPKA Rdnr,_7nl7
11►1�1IT C 111A11AA�V Gf`L(1 ICT D=PCIRT
INFILTRATION
# Scope Method
SLAT
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.00039
F
2336.5 128.27 241.24 .3037 6.6
HEATING SYSTEM
# System Type
Subtypp
Efficiency Capacity Block
Ducts
1 Electric Strip Heat/
None
I
COP:1 34 kBtu/hr 1
sys#1
COOLING SYSTEM
=;V. # System Type
Subty
a
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
SEER: 16 48 kBtu/hr 1440 cfm 0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt Conservation
1 Electric None
Garage
0.94 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ftZ
DUCTS
Supply ----
V # Location R-Value Area
-- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1 Attic 6 702 ft2
Attic
489 ft2 Default Leakage Main (Default) (Default)
1 1 a
TEMPERATURES
Programable Thermostat: Y
Cooling [[� jj Jan [ Feb Mar
Heating [X] Jan X FebMar
Ventin [[ ]] Jan [[ Feb X Mar
I
[ ] A
[ ]Ar
[X] Apr
Ceiling Fans:
r May [Xj Jun Jul JXJ Au Se [ j Oct Nov
Jul Auf SeP [ ]Oct Nov
[ Ma [ ] Jun Jul Aug [ Se [X] Oct X Nov
l May [ ]Jun jxj�
Dec
Dec
Dec
ti4+
1/28/2019 9:48 AM
USA Section R405.4.1 Compliant Software
r
Page 4 of 5
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
=Cooling,(WD)
AM
78
78
�8
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
178
78
78
78
78
78
78
78
78
78
PM
78
78
8
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/s
.ft.
Oft.
0 ft
0.3
Main
Name:
Rating Compant:
Signature:
Date:
1/28/2019 9:48 AM Enerk yGauge® USA Section R405.4.1 Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy
Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity 48.0
a) Split system SEER 16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2284
d) Room unit/PTAC EER
e),Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.620
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.260 -
14. Heating system: Capacity 34.0
c) Area
7c. 380.4
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP 1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 11.0
2. Masonry (Insulation R-value)
10132,
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a. 30.0
b) Cross ventilation No
b) Single assembly
11 b.
c) Whole house fan No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of t
e Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or,
exceeded) in this home before
final inspection. Otherwise, a new EPL
display card will be completed based on installed
code compliant features.
Z s JA N i 9
Builder Signature: i
Date:
Address of New Hom 3218 BENT PINE
DR
City/FL Zip. FORT PIERCE, FL 34951
1/28/2019 9:48:40 AM EnergyGaUge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1