Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE.� FILt FORM R405-2017 .� FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-277 Builder Name: Street: 3218 BENT PINE DR Permit Office: City, State, Zip: FORT PIERCE, FL, 34951 ®v BY _ Permit Number: Owner: Jurisdiction: LUCIE_CO_INTL �t Lucie /Mumtounty: Design Location: FL, ST l St. Lucie (Florida Climate Zone 2 ) Im 1. New construction or existing New (Fr Plans) 9. Wall Types (2381.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 2071.40 ftz b. Frame - Wood, Adjacent R=11.0 309.78 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 10. Ceiling Types (2284.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2284.00 ftz 6. Conditioned floor area above grade (ftz) 2284 b. N/A R= ftz ' c. N/A R= ftz Conditioned floor area below grade (ftz) 0 11. Ducts R ftz 7. "Windows(380.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 702 �al U-Factor: Dbl, U=0.62 380.43 ftz = SHGC: SHGC=0.26 b. U-Factor: N/A ftz 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 48.0 SEER:16.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2284.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2284.00 ftz b. Conservation features b. N/A R= ftz None a c; N/A R= ftz 15. Credits Pstat Glass/Floor Area: 0.167 Total Proposed Modified Loads: 73.66 PASS I Total Baseline Loads: 75.06 �I hereby certify that the as dUificat!red by Review of the plans ando4ZHE 5rg1this calculation arein compliant ergy specifications covered by this indicates Code. calculation compliancev.with the Florida Energy Code.rnPREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 i - a _ I hereby certi)y t t"ttlis wilding, as dee i ned, is in compliance Code. M Florida Statutes. with the Florida Ene�rg COD WE f ....OWNER/AGENT BUILDING OFFICIAL: DATE: A"-�� DATE: _ i Compliance requires certification bylthe air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with en lope leakage no greater than 6.60 ACH50 (11402.4.1.2). I 1/28/2019 9:48 AM I EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 k- . t FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT I PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-277 User 1 Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 2284 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 3218 BENT PINE DR St. Lucie FORT PIERCE, FL, 34951 - I CLIMATE / V Design Location TMY Site Design Temp 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST—LUCIE—CO INTL FL_VERO BEACH MUNI 39 90 70 75 299 58 Medium I BLOCKS 'Number Name Area Volume 1' Blockl 2284 21241.2 I SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2284 21241.2 Yes 4 3 1 Yes Yes Yes I FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio I Main 209.9 ft 0 2284 ft2 __-- 0 0 1 ROOF / V; # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Barrel the 2554 ft2 0 ft2 Medium 0.4 N 0.9 No 0 26.6 ATTIC V # Type Iventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic i Vented 150 2284 ft2 N N I CEILING # Ceiling Type I Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2284 ft2 0.1 Wood I 1/28/2019 9:48 AM I EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 Pr)PRA Rangy-2017 INPUT Sl1MM,4RY CHECKLIST REPORT I WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below V#-Llrnt To Wall -Type _ Space _flue-Ft-In-Et-ln Area R-value-Fraction-Absor-Grade%-- _ 1 N Exterior Concrete Block - Ext Insul Main 4 32 0 11 4 362.7 ft2 0 0 0.3 0 _ 2 E Exterior . Concrete Block - Ext Insul Main 4 55 0 9 4 513.3 ft2 0 0 0.3 0 3 S Exterior Concrete Block - Ext Insu� Main 4 58 2 9 4 542.9 ft2 0 0 0.3 0 _ 4 SW Exterior Concrete Block - Ext Insu Main 4 8 9 11 4 99.2 ft2 0 0 0.3 0 _ 5 W Exterior Concrete Block - Ext Ins II Main 4 55 9 9 4 520.3 ft' 0 0 0.3 0 _ 6 NW Exterior Concrete Block - Ext Ins�l Main 4 2 11 11 4 33.1 ft2 0 0 0.3 0 7 - Garage Frame - Wood I Main 11• 27 4 11 4 309.8 ftz 0 0.25 0.3 0 I DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood Main None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 30.0 ft2 0 ft 0 in 0 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 6.0 ft2 0 ft 0 in 0 ft 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.26 N 8.0 ft2 0 ft 0 in 0 ft 0 in None None 4 n 1 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 0 ft 0 in 0 ft 0 in None None 5 e 2 Metal Double (Clear) Yes 0.62 0.26 N 20.7 ft2 0 ft 0 in 0 ft 0 in None None 6 e 2 Metal Double (Clear) Yes 0.62 0.26 N 43.3 ft2 0 ft 0 in 0 ft 0 in None None 7 e 2 Metal Double (Clear) Yes 0.62 0.26 N 4.5 ft2 0 ft 0 in 0 ft 0 in None None 8 s 3 Metal Double (Clear) Yes 0.62 0.26 N 42.9 ft2 0 ft 0 in 0 ft 0 in None None 9 s 3 Metal Double (Clear) Yes 0.62 0.26 N 96.0 ft2 0 ft 0 in 0 ft 0 in None None 10 s 3 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft2 0 ft 0 in 0 ft 0 in None None 11 s 3 Metal Double (Clear) Yes 0.62 0.26 N 6.5 ft2 0 ft 0 in 0 ft 0 in None None 12 sw 4 Metal Double (Clear) Yes 0.62 0.26 N 18.7 ft2 0 ft 0 in 0 ft 0 in None None 13 sw 4 Metal Double (Clear) Yes 0.62 0.26 N 18.5 ft2 0 ft 0 in 0 ft 0 in None None 14 w 5 Metal Double (Clear) Yes 0.62 0.26 N 20.7 ft2 0 ft 0 in 0 ft 0 in None None 15 w 5 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft2 0 ft 0 in 0 ft 0 in None None 16 NW 6 Metal Double (Cleary) Yes 0.62 0.26 N 10.0 ft2 0 ft 0 in 0 ft 0 in None None I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 686 ft2 686 ft2 1 64 ft 9.3 ft 1 1/28/2019 9:48 AM I EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5 GnPKA Rdnr,_7nl7 11►1�1IT C 111A11AA�V Gf`L(1 ICT D=PCIRT INFILTRATION # Scope Method SLAT CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .00039 F 2336.5 128.27 241.24 .3037 6.6 HEATING SYSTEM # System Type Subtypp Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None I COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM =;V. # System Type Subty a Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 48 kBtu/hr 1440 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftZ DUCTS Supply ---- V # Location R-Value Area -- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 702 ft2 Attic 489 ft2 Default Leakage Main (Default) (Default) 1 1 a TEMPERATURES Programable Thermostat: Y Cooling [[� jj Jan [ Feb Mar Heating [X] Jan X FebMar Ventin [[ ]] Jan [[ Feb X Mar I [ ] A [ ]Ar [X] Apr Ceiling Fans: r May [Xj Jun Jul JXJ Au Se [ j Oct Nov Jul Auf SeP [ ]Oct Nov [ Ma [ ] Jun Jul Aug [ Se [X] Oct X Nov l May [ ]Jun jxj� Dec Dec Dec ti4+ 1/28/2019 9:48 AM USA Section R405.4.1 Compliant Software r Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 =Cooling,(WD) AM 78 78 �8 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 178 78 78 78 78 78 78 78 78 78 PM 78 78 8 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/s .ft. Oft. 0 ft 0.3 Main Name: Rating Compant: Signature: Date: 1/28/2019 9:48 AM Enerk yGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 48.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2284 d) Room unit/PTAC EER e),Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 - 14. Heating system: Capacity 34.0 c) Area 7c. 380.4 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132, 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of t e Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or, exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Z s JA N i 9 Builder Signature: i Date: Address of New Hom 3218 BENT PINE DR City/FL Zip. FORT PIERCE, FL 34951 1/28/2019 9:48:40 AM EnergyGaUge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1