Loading...
HomeMy WebLinkAbout0504-0180 ENERGY EFFICIENCY CODEFORM 60OA-2001 I r FLORIDA ENERGY EFFICIENCY CODE GANNED FOR BUILDING CONSTRUCTION Florida Departme I t of Community Affairs �4L��eesi Residential Whole Building Performance Method A Project Name: Perrine-Premier I Builder: Address: ; Permitting Office: I 6SO 4 ,' c� f �U City, State: Permit Number: Owner: i Jurisdiction Number: Climate Zone: Central 1. New construction or existing Newl _ 12. Cooling systems 2. Single family or multi -family Single family, a. Central Unit Cap: 23.0 kBtu/hr 3. Number of units, if multi -family _ 1� _ _ SEER: 12.00 _ 4. Number of Bedrooms 2 _ b. N/A _ 5. Is this a worst case? No 6. Conditioned floor area (ft2) '990 ft2 c. N/A 7. Glass area & type Single Pane Double Pane a. Clear glass, default U-factor 0.0 ft2 0.0 ft2 _ 13. Heating sys b. Default tint 0.0 ft2 0.0 ft2 _ a. Electric Hea p Cap: 23.6 kBtu/hr c. Labeled U or SHGC 194.0 ft2 0.0 ft2 HSPF: 7.50 8. Floor types _ _ b. N/A a. Slab -On -Grade Edge Insulation R=0.0, 128.2(p) ft b. Raised Wood, Stem Wall ; ft2 _ c. N/A c. N/A 9. Wall types I _ 14. Hot water systems a. Frame, Wood, Exterior R=19.0, 833.0 ft2 _ a. Electric Resistance Cap: 40.0 gallons _ b. N/A _ EF: 0.90 _ c. N/A _ b. N/A _ d. N/A e. N/A i c. Conservation credits 10. Ceiling types _ (HR-Heat recovery, Solar a. Under Attic R=30.0, 990.2 ft2 _ DHP-Dedicated heat pump) b. N/A ; _ 15. HVAC credits PT, c. N/A (CF-Ceiling fan, CV -Cross ventilation, 11. Ducts i _ HF-Whole house fan, a. Sup: Unc. Ret: Con. AH: Interior Sup. R=6.0,I100.0 ft _ PT -Programmable Thermostat, b. N/A MZ-C-Multizone cooling, I MZ-H-Multizone heating) Glass/Floor Area: 0.20 Total as -built points: 12361 PASS Ti otal base points: 14739 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida E ergy ode. OWNERIAGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 -Florida Statutes. BUILDING OFFICIAL: DATE: sion: FLRCSB v3.30) r FORA 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , I PERMIT #: I BASE I AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 990.0 25.78 4594.0 Single, SC� 0.43 E 1.5 14.2 34.0 24.47 0.99 826.8 Single, S9=0.43 S 1.5 10.7 10.0 17.29 0.97 167.7 Single, SC=0.43 E 1.5 12.8 48.0 24.47 0.99 1166.4 Single, SC=0.43 S 1.5 12.8 16.0 17.29 0.99 273.4 Single, SC=0.43 S 1.5 12.8 16.0 17.29 0.99 273.4 Single, SC=0.43 N 1.5 9.7 10.0 9.07 0.98 88.9 Single, SC=0.43 W 1.5 5.7 17.0 21.58 0.91 332.5 Single, SC=0.43 W 5.5 8.2 34.0 21.58 0.65 475.7 Single, SIC=0.43 N 1.5 5.7 9.0 9.07 0.93 76.3 As -Built Total: 194.0 3681.1 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 19.0 833.0 1.00 833.0 Exterior 833.0 1.90 1582.7 I Base Total: 833.0 1582.7 As -Built Total: 833.0 833.0 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 20.0 7.20 144.0 Exterior 20.0 4.80 96.0 Base Total: 20.0 96.0 As -Built Total: 20.0 1".0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 990.2 2.13 2109.1 Undei Attic 30.0 990.2 2.13 X 1.00 2109.1 Base Total: 990.2 2109.1 As -Built Total: 990.2 2109.1 FLOOR TYPES Area X BSPM = Points I Type R-Value Area X SPM = Points Slab 128.2(p) -31.8 -4076.8 SlabOn-Grade Edge Insulation 0.0 128.2(p -31.90 -4089.6 Raised 66.0 -3.43 -226.4 Rai ied Wood, Stem Wall 19.0 66.0 -1.80 -118.8 Base Total: -4303.1 As,' Built Total: 194.2 -4208.4 INFILTRATION Area X BSPM = Points Area X SPM = Points 990.0 14.31 14166.9 I 990.0 14.31 14166.9 I EnergyGauge® DCA Form 60OA-2001 EnergyGl uge®/FlaRES'2001 FLRCSB v3.30 I I FORU 600A-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE I AS -BUILT Summer Base Points: 18245.6 Summer As -Built Points: 16725.8 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 18245.6 0.4266 7783.E 1 16725.8 1672.5.8 1.000 1.00 (1.079 x 1.150 x 0.90) 0.284 1.117 0.284 0.950 0.950 5042.5 5042.5 EnergyGaugeTm DCA Form 60OA-2001 EnergyG6uge®/FIaRES'2001 FLRCSB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , i PERMIT #: BASE I AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point .18 990.0 5.86 1044.3 Single, Sd=0.43 E 1.5 14.2 34.0 14.85 1.00 506.8 Single, S6=0.43 S 1.5 10.7 10.0 13.57 1.00 135.7 Single, SC=0.43 E 1.5 12.8 48.0 14.85 1.00 715.8 Single, SC=0.43 S 1.5 12.8 16.0 13.57 0.99 215.9 Single, SC=0.43 S 1.5 12.8 16.0 13.57 0.99 215.9 Single, SC=0.43 N 1.5 9.7 10.0 16.22 1.00 161.8 Single, SC=0.43 W 1.5 5.7 17.0 15.28 1.01 263.0 Single, SAC=0.43 W 5.5 8.2 34.0 15.28 1.06 552.2 Single, IC=0.43 N 1.5 5.7 9.0 16.22 1.00 145.4 As -Built Total: 194.0 2912.7 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 19.0 833.0 1.10 916.3 Exterior 833.0 2.00 1666.0 Base Total: 833.0 1666.0 As -Built Total: 833.0 916.3 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 20.0 7.60 152.0 Exterior 20.0 5.10 102.0 I Base Total: 20.0 102.0 As -Built Total: 20.0 152.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 990.2 0.64 633.7 Under Attic 30.0 990.2 0.64 X 1.00 633.7 Base Total: 990.2 633.7 As -Built Total: 990.2 633.7 FLOOR TYPES Area X BWPM = Points i Type R-Value Area X WPM = Points Slab 128.2(p) -1.9 -243.6 Slati-On-Grade Edge Insulation 0.0 128.2(p 2.50 320.5 Raised 66.0 -0.20 -13.2 Raised Wood, Stem Wall 19.0 66.0 0.30 19.8 Base Total: -256.8 Ash -Built Total: 194.2 340.3 INFILTRATION Area X BWPM = Points I Area X WPM = Points 990.0 -0.28 -277.2 I 990.0 -0.28 -277.2 I I EnergyGauge® DCA Form 600A-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30 I i i FORM 600A-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details [ADDRESS: , , , PERMIT #: I BASE I AS -BUILT Winter Base Points: 29170 Winte' As -Built Points: 4677.9 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Compoi ent Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 4677.9 1.000 (1.066 x 1.160 x 0.92) 0.455 0.950 2305.0 2912.0 0.6274 1827.0 1 4677.9 1.00 1.140 0.455 0.950 2305.0 EnergyGaugeTm DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30 FORM 60OA-2001 ` WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE I AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2664.00 5128.0 40.0 I 0.90 2 1.00 2507.02 1.00 5014.0 As -Built Total: 5014.0 CODE I COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 7784 1827 5128 14739 5042 2305 6014 12361 EnergyGaugeTm DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30 FORM 60OA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , ! PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfrn/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & walli sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeterj penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with il/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on piiometer of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. iRA-77 InTI49:R PRFCf`_RIPTIVF MFACI IRFQ /mnc4 n mn4 e..--^A^A 1— -11 - _;.1....--- � COMPONENTS SECTION - ----------- - --- ------------ REQUIREMENTS CHECK Water Heaters 612.1 Comply with efi fciency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30 ENERGY PERFO DISP CE LEVEL (EPL) Y CARD - a/ffo ESTIMATED ENERGY PERFORMANCE SCORE* = 87.0 The higher the score, Ithe more efficient the home. 1. New construction or existing New 1 2. Single family or multi -family Single family 3. Number of units, if multi -family 1 4. Number of Bedrooms 2 5. Is this a worst case? No 6. Conditioned floor area (ft2) 990 ft2 7. Glass area & type Single Pane Double Pane a. Clear - single pane 0.0 ft2 0.0 ft2 b. Clear - double pane 0.0 ft2 0.0 ft2 L c. Tint/other SHGC - single pane 194.0 ft2 0.0 ft2 d. Tintlother SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 128.2(p) ft b. Raised Wood, Stem Wall R=19.0, 66.0ft2 c. N/A 9. Wall types I - a. Frame, Wood, Exterior R=19.0, 833.0 ft2 I- b. N/A c. N/A _ d. N/A _ e. N/A 10. Ceiling types a. Under Attic R=30.0, 990.2 ft2 b. N/A ! _ c. N/A 11. Ducts 12. Cooling systems a. Central Unit Cap: 23.0 kBtu/hr _ SEER:12.00 b. N/A c. N/A 1 eating systems 1 5 HeaQump Cap: 23.6 kBtu/hr HSPF:7.50 _ b. c. N/A opy 14. Hot water systems a. Electric Resistance Cap: 40.0 gallons - EF: 0.90 b. N/A c. Conservation credits _ (HR Heat recovery, Solar DIP -Dedicated heat pump) 15. HVAC credits PT, - (CF-Ceiling fan, CV -Cross ventilation, BF -Whole house fan, _ PT -Programmable Thermostat, a. Sup: Unc. Ret: Con. AH: Interior Sup. R=6.0, 100.0 ft _ MZ-C-Multizone cooling, b. N/A MZ-H-Multizone heating) I I I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code co pliant features. Builder Signature: � � Date: '4/4067 Address of New Home: \ \\ \ City/FL Zip: *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or' greater (or 86 for a US EPADOE EnergyStardesignation), your home may qualifyfor energy efficiency mortgage (EE.) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCSB v3.30) Project Summa°b Date: March 25, 2005 Entire House By: mm Coastal Heating & Air Cond., Inc. •984 SW Jack James Drive, Stuart, FL 34997 Phone: 772-288-4829 Aply For: Notes: Perrine Residence ,r 4 Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Buildingg heat loss 15362 Btuh Ventilafion air 0 cfm Ventilation air loss 0 Btuh Design heat load 15362 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (ft') Air changes/hour Equiv. AVF (cfm) Simplified Average 0 Heating Cooling 8020 8020 0.75 0.35 100 47 Heating Equipment Summary Make Carrier Trade WeatherMate 38BYC Model 38BYCO2431 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 7.5 HSPF 23600 BFuh @ 47°F m I 0.000 cfm/Btuh 0.00 in H2O Heat\Cool I Sensible Cooling Equipment Load Sizing Structure 15767 Btuh Ventilation 0 Btuh Design temperature swing 3.0 OF Use mfg. data y Rate/swing multiplier 1.00 Total sens. equip. load 15767 Btuh Latent Cooling Equipment Load Sizing Internal gains 600 Btuh Ventilation 0 Btuh Infiltration 1954 Btuh Total latent equip. load 3369 Btuh Total equipment load 19137 Btuh Req. total capacity at 0.70 SHR 1.9 ton Cooling Equipment Summary Make Carrier Trade WeatherMate 38BYC Cond 38BYCO2431 Coil FC4BNF030 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 12 SEER 16100 Btuh 6900 Btuh 23000 Btuh 767 cfm 0.049 cfm/Btuh 0.00 in H2O 82 % Printout certified by ACCA to meet all requirements of Manual J 8th Ed. rgl wnghtsoft Right -Suite Residential5.9.11 RSR31712 2005•Mar-2713:56:01 AM C:1My Documents\Wrightsoft HVAC\Jobs\Perrine-Premier.rrp Calc = MA Orientation = N Page 1 I Right,J Worksheet Entire House Coastal Heating & Air Cond., Inc. .984 SW Jack James Drive, Stuart, FL 34997 Phone: 772-2884829 Job: Date: March 25, 2005 By: mm 1 Room name Entire House Kitchen/Dining 2 Exposed wall 134.0 ft 28.3 It 3 Ceiling height 8.1 ft d 8.1 ft heat/cool 4 Room dimensions 17.0 x 11.3 It 5 Room area 990.2 ftz 192.1 ftz Ty Construction U-value Or HTM Area (W) Load Area (1`12) Load number (Btuh/ft'--`F) (Bt or, perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-Osw - -0.068' . n; , 1:90• - , 1.35 290 --", 261 476 '. 34. 0 - " ^ -6 0 .. 0' 0 61B 0.570 .'n 16M. .16.31 _0 A - 0 0 0 0 0 0 61B = 0570 -n 15.96 16.31. 10 0 160 163 0 0 0 0 61B 0.570 n 15.96 16.31 9 0 . 144 147 0, 0. 0 : 0 11 1.1.00 0.390, _n_- _ 10;92 ." 11:31 ". 20 _.:: _-20. " . 2]8; 226' 0 .. 0 __ _ ..0 -- - °.- _0. , . W _ 12E-0sw 0.068 a 1.90 1.35 175 93 177 126 92 58 110 78 61C 0.570 a 15.96 44.10 34 0 543 1500 34 0 543 1500 61 B 0.570 a 15.96 44.10 48 0 766 2117 0 0 0 -_ 0 W , 12E-06w 0.068 s 1.90 1.•. 35 -408 -" W6 697 . 495 136 _ - 128 244 `in 61B 0.570: , s 15.96 17.84 10' . 10 160 - 163 10 10 160 163 61B 0.576 s 15.96, 17.84 16 _ '„ ' 16 . 255 261 D 0 '0 . 0 , 616 A.570 s 15.96 17.84 ' 16 ' 16 255 261 0 0 0 , 0 616` _ 0:570:_s`.-_15.96 >.-17.84` :" 0 ...`0.-0 -0 -0 0 . _ ._0. W 12E-Osw 0.068 w 1.90 1.35. 174 123 234 166 0 0 0 0 Es61B 0.570 w 15.96 44.10 17 0 271 750 0 0 0 0 61C 0.670 w 1&96 44,10 34 16 543 1067 0 0 0 0 P 12E-0bw _ .0068 . - _ .-.1.90:'- 056 :--0 . 0 - .,_ 0 0, _. -0 0 0._ V_ _. 0 C 16C-30a1 0.032 - 0.90 1.36 990 990 887 1347 -` 192 192 172 261 f.': 22A-tph _ .- _ 1.358 - : 36:02 0;00 - .925 ;_ _ .- 128 ., 48 -5- _ , : _ _ 0 _ _ 192 - _ 26 - 1076 - . 0 F 20P-19t 0.050 - 1.40 0.63 66 6 92 41 0 0 0 0 Envelope loss/gain 10755 9170 2305 2176 12 a) Infiltration 3085 771 678 169 b) Ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 0 0 Appliances @ 1200 2 2400 1 1200 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 13840 13031 2982 3545 15 Duct loads 11% 21% 1522 2736 11% 21% 328 744 Total room load 15362 15767 W10 4289 Air required Winn) 01 767 0 209 Printout certified by ACCA to meet all wrrgl ltsofit RightSuite Residential 5:9.11 RSR31712 C:Wy DocumentslWrightsoft HVAC1JobslPerrine-Premier.rrp Calc = M, Orientation = N of Manual J 8th Ed. 2005-Mar-2713:56:02 Page 1 Right-J Worksheet Entire House Coastal Heating & Air Cond., Inc. 984 SW Jack James Drive. Stuart, FL 34997 Phone: 772-288-4829 Job: Date: March 25, 2005 By: mrn 1 Room name Living Bedroom 2 2 Exposed wall 23.5 ft 11.8 It 3 Ceiling height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 15.0 x 10.3 ft 11.8 x 11.3 ft 5 Room area 154.5 ft2 133.3 ftz Ty Construction U-value Or HTM Area (ft� Load Area (ftj Load number (Btuh/ft--'F) (Btuh/" or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-Osw 0.068 n 1.90 1.35 1 0 0 0 0 0 0 0 0 61 B 0.570 n 15.96 16.31 0 0 0 0 0 0 0 0 N 61 B 0.570 n 15.96 16.31 I 0 0 0 0 0 0 0 0 61 B 0.570 n 15.96 16.31 0 0 0 0 0 0 0 0 11 11 DO 0.390 n. 10.92 11.31 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 a 1.90 1.35 1 83 35 67 47 0 0 0 0 61 C 0.570 a 15.96 44.10 1 0 0 0 0 0 0 0 0 61 B 0.570 a 15.96- 44.10 1 48 0 766 2117 0 0 0 0 W 12E-Osw 0.068 s 1.90 1.35 93 77 147 104 96 80 152 108 61 B 0.570 s 15.96 17.84 0 0 0 0 0 0 0 0 61 B 0.570 s 15.96 17.84 16 16 255 261 0 0 0 0 61 B 0.570 s 15.96 17.84 0 0 0 0 16 16 255 261 61 B 0.570 s 15.96 17.84 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 w 1.90 1.35 0 0 0 0 0 0 0 0 61 B 0.570 w 15.96 44.10 I 0 0 0 0 0 0 0 0 61 C 0.570 w 15.96 44.10 0 0 0 0 0 0 0 0 P 12E-Obw 0.068 - 1.90 0.56 ' 0 0 0 0 0 0 0 0 C 16C-30al 0.032 - 0.90 1.36 I 155 155 138 210 133 133 119 181 F 22A-tph 1.358 - 38.02 0.00 j 155 24 894 0 133 12 449 0 F 20P-19t 0.050 - - 1.40 0.63 0 f i i I I `j I II 0 0 0 0 _ 0 0 0 Envelope loss/gain 2267 2740 976 551 12 a) Infiltration 519 130 283 71 b) Ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2785 2869 1259 851 15 Duct loads 11% 21% 306 603 11% 21% 138 179 Total room load 3092 3472 1397 1030 Air required (cfm) 0 169 0 50 Printout certified by ACCA to meet all wngl-�tso1F� Right-Sufte Residential 5.9.11 RSR31712 .4CCA C:Wy Documents\Wrightsoft HVAC\Jobs\Perrine-Premier.rrp Calc = MJ8 Orientation = N of Manual J 8th Ed. 2005-Mar-2713:56:02 Page 2 Right-J Worksheet Job: Entire House Date: March 25, 2005 By: MM Coastal Heating & Air Cond., Inc. 984 SW Jack James Drive, Stuart, FL 34997 Phone: 772-288-4829 1 Room name Bath 2/Util Hall/Stairs 2 Exposed wall 10.8 ft 4.0 ft 3 Ceiling height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 10.8 x 6.5 ft 70.0 x 1.0 It 5 Room area 70.2 ft2 70.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ftj Load number (Btuh/ff- °F) (Btuh/n or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-Osw 0.068 n 1.90 1.3-5 f 87 82 156 111 32 12 23 16 61 B 0.570 n 15.96 16.3.1 } 0 0 0 0 0 0 0 0 61 B 0:570 n 15.96 16.31 5 0 80 82 0 0 0 0 61 B 0.570 n 15.96 16.31 0 0 0 0 0 0 0 0 11 11 DO 0.390 - n 10.92 11.31 I 0 0 0 0 _ 20 20 218 226 12E-Osw 0.068 a 1.90 1.35 0 0 0 0 0 0 0 0 IW 61 C 0.570 a 15.96 44.10 0 0 0 0 0 0 0 0 L- G 61 B 0.570 a 15.96 44.10 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 1.90 1.35 0 0 0 0 0 0 0 0 61 B 0.570 s 15.96 17.84 0 0 0 0 0 0 0 0 61B 0.570 s 15.96 17.84 0 0 0 0 0 0 0 0 61 B 0.570 s 15.96 17.84 0 0 0 0 0 0 0 0 61 B 0.570 - s 15.96 17.84 0 0 0 0 0- 0 0 0 W 12E-Osw 0.068 w 1.90 1.35 0 0 0 0 0 0 0 0 61 B 0.570 w 15.96 44.10 0 0 0 0 0 0 0 0 61 C_ 0.570 w 15.96 44.10 ! 0 0 0 0 0 0 -0 0 0 P 12E-Obw 0.068 _ - 1.90 0.56 0 0 0 0- 0 0 0 C 16C-30al 0.032 - 0.90 - 1.36. 70 70 63 95 70 70 63 95 F 22A-tph 1.358 - 38.02 _ 0.00 70 11 411 0 70 - 4 152 0 F 20P-19t 0.050 - _ 1.40 0.63 ., 0 f t i i 0 0 0 0 0 0 0 Envelope loss/gain 1 709 288 456 338 12 a) Infiltration 256 64 94 24 b) Ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 1 1200 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 966 1552 550 361 15 Duct loads 11% 21% 106 326 11% 21% 61 76 Total room load 1072 1878 1 611 437 Air required (cfm) 01 91 1 01 21 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnyht50fC Right-Sufte Residential 5.9.11 RSR31712 2005-Mar-2713:56:02 /CCX C:\My Documents\Wrightsoft HVAC\Jobs\Perrine-Premier.rrp Calc = MJ8 Orientation = N Page 3 Right-J Worksheet Entire House Coastal Heating & Air Cond., Inc. 984 SW Jack James Drive, Stuart, FL 34997 Phone: 772-288-4829 Job: Date: March 25, 2005 By: rnm 1 Room name M. Bath Master Bedroom 2 Exposed wall 5.8 ft 49.8 ft 3 Ceiling height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 5.8 x 11.3 ft 304.5 x 1.0 ft 5 Room area 65.5 ftz 304.5 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ftq Load number (Btuh/ft? "F) (Btuh/" or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-Osw 0.068 n 1.90 1.35 47 42 80 57 124 115 219 156 61 B 0.570 n 15.96 16.31 0 0 0 0 0 0 0 0 61 B 0.570 n 15.96 16.31 5 0 80 82 0 0 0 0 N 61 B 0.570 n 15.96 16.31 f 0 0 0 0 9 0 144 147 11 111130 0.390 n 10.92 11.31 j 0 0 0 0 0 0 Q- 0 IW 12E-Osw 0.068 a 1.90 1.35 0 0 0 0 0 0 0 0 61 C 0.570 a 15.96 44.10 0 0 0 0 0 0 0 0 1� 61 B 0.570 a 15.96 44.10 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 1.90 1.35 0 0 0 0 81 81 154 110 61 B 0.570 s 15.96 17.84 0 0 0 0 0 0 0 0 61 B 0.570 s 15.96 17.84 0 0 0 0 0 0 0 0 61 B 0.570 s 15.96 17.84 0 0 0 0 0 0 0 0 61 B 0.570 s 15.96 17.84 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 w 1.90 1.35 I 0 0 0 0 174 123 234 166 EG 61 B 0.570 w 15.96 44.10 0 0 0 0 17 0 271 750 G 61C 0.570 w 15.96 44.10 0 0 0 0 34 16 543 1067 P 12E-Obw 0.068 - 1.90 0.56 0 0 0 0 0 0 0 0 C 16C-30al 0.032 - 0.90 1.36 66 66 59 89 305 305 273 414 F 22A-tph 1.358 - 38.02 0.00 1 0 0 0 0 305 _ 50 1894 - 0 F 20P-19t _ 0.050 - 1.40 - 0.63 1 66 I f I i j F 6 92 41 0 0 - 0 0 Envelope loss/gain 1 311 2691 3731 2810 12 a) Infiltration i 138 35 1117 279 b) Ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 449 303 4848 3549 15 Duct loads 11% 21% 49 64 11% 21% 533 745 Total room load 499 367 5381 4294 Air required (cfm) 0 18 0 209 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�glltsOFC Right -Suite Residential5.9.11 RSR31712 2005-Mar-2713:56:02 ACC-N C:WIy Documents\Wrightsoft HVAC\Jobs\Perrine-Premier.rrp Calc = MJ8 Orientation = N Page 4