Loading...
HomeMy WebLinkAbout0504-0180 BUILDING PLANS32'-11" 14'-9" ---------------------------- ------------------------ -------- -I ------------------ ------------------ \\ \\ A INDICATES 1 #5 DOWEL IN I GROUT FILLED CELLS WITH I \ \ HOOK AT AND TIE \ \ BEAM. BARR LAP LAP MUST BE 25" \ \ MIN. 13%0" O.C. MAX. SPREAD. 1 ` \\ CONCRETE SLAB \ \\ I 4" SLAB WITH 6X6 #10/10 W.W.M. (2500 P.S.I.) r' \ `\ (FIBER MESH OPT.) OVER 6 MIL VAPOR BARRIER \ \ T/1� NNCLEAN COMPACTED TERMITE TREATED FILL. \ \\ I (���i 5 1 Tw � \ C11 -- 8'-6„------ ----- -� I I I I m I a I I� I� I� I I 0+4" G o r-- L - - - --� 1 LET— \ I I L I - - \ \ \ 0+34^ ,- I - - - -1 I 9' 0+0„ I \ I \ / A 7N I I I +4" \ - Q 5' x 7' OPENING Q. Q � i(,---------- -- - ------------------ -- --'---------- -- -�'--------I-------� -'- 25'-1 WINDOW SCHEDULE CAST CRETE LINTEL SCHEDULE ® LENTH SAFE LOAD LBS/LIN.FT. SIZE NAILING FILLED COMPOSITE Ti68 A 36"x63 S.H. 10 8D NAILS 4'-O" 6039 B 36"x38" S.H. 10 8D NAILS 4'-6" 6039 C '\ C 26"x26" S.H. 10 8D NAILS 5'-4" 5057 \� D 48"x50" S.H. 10 8D NAIL) 6'-6" 3396 �-----------------� C E 26"x50" S.H. 10 8D NAILS 7'-6" 2610 9'-4" 1818 SCAN 11'-4" 1365 ;.. 12 ' - 0 " 1254 \ St Lucie 13'-4" 1076 ` 14 ' - 0 " 10 0 3 \ ` N 79°30'00" E 65.00' ` 14'-8" 1370 15' -4" 1250 950 s so NOTE: �$ m REVIEWED & APPROVED PGT IMPACT FILLED LINTELS: ----� RESISTANT SINGLE HUNG WINDOWS & DOORS BOTH PRECAST LINTELS AND PERIMETER BEAM I �` o�� $ \ FOR THIS STRUCTURE. AS DRAWN ON PLAN. HAVE 1 #5 CONTINUOUS. APPROVED 30 YEAR GAF ARCHITECTURAL N7930'00"E65.00' SHINGLES FOR THIS STRUCTURE. DESIGN PARAMETERS THFSFp//,, AE��q��✓P TT�q�q(l CODE EDITION: \ \ �gy6P ' ByFj 41yC SIMPSON SP40R FLORIDA BUILDING CODE 2001 ' �` �,1p NE FS F(D/NS SP1 BOTTOM ° CHAPTER 6 OF ASCE 7-98 i \e 0 (Y C S p OCCUPANCY CATEGORY: qAY 1/2" WEDGE ANCHOR ❑ npL IL EVERY 48" D.C. TO EXPOSURE CATEGORY: C p(�Cq�`�r0 x 2"x4"P.T.BOTTOMPLATE BASIC WIND PRESSURE: -33 PSF N BASIC WIND SPEED: 140 MPH �S INTERNAL PRESSURE COEFFICIENT = ±0.18 LEGAL DESCRIPTION DOORS & WINDOWS: (EDGE ZONE) +45.5 PSF -59.4 PSF LOT 390, NETTLES ISLAND PROJECT, o - °. MINIMUM GRADE LUMBER TO BE NO. 2 OR NETTLES ISLAND, PLAT HOOK 16, PAGE 1G, PUBLIC RECORDS f#5REBAR BETTER. RIDGE VENT 23' WITH CONTINUOUS OF ST, LUCIE COUNTY, FLORIDA. joNr. SOFFIT VENT. Ipjp Obi u �NLA PLOT S .006 MIL VAPOR BARRIER ON CLEAN NOTE THIS IS NOT A SURVEY. COMPACTED TERMITE TREATED FILL. 0+34" Ak 8'-6" QF f ELEV.F-10",� FINISH FLOOR ' Ib Ib ELEV.8'-0" FLOOD ZONE III III N .006 MIL VAPOR BARRIER ON CLEAN COMPACTED TERMITE TREATED FILL.Ilk - =- ELEV. _ III - III --°---a--��------------'�----•^^--`-- 4 . -- -- • 'v FINISH SLAB iII _- III MIL VAPOR BARRIER - - I I .006 MIL VAPOR BARRIER ON ° " a .006 T CLEAN COMPACTED TERMITE _ III CLEAN COMPACTED TERMITE .006 MIL VAPOR BARRIER ARRIER ON TREATED FILL. _ - I _ T. TREATED FILL CLEAN COMPACTED TERMITE TREATED FILL. I° _ i a -•:� a . IF�zk 1'-8" (3) 05 RODS CONT. ON 20 (3) #5 RODS CONT. ON CHAIRS WITH CORNER BENDS CHAIRS WITH CORNER BENDS .006 MIL VAPOR BARRIER ON CLEAN COMPACTED TERMITE TREATED FILL. � _ - E�.�`i' ELEV.6'+4" \qrFINISH SLAB FINISH SLAB .006 MIL VAPOR BARRIER ON CLEAN COMPACTED TERMITE TREATED FILL. ENT II - I�I = ICI - III - a I a .006 MIL VAPOR BARRIER ON -� a CLEAN COMPACTED TERMITE TREATED FILL. , ELEV. V-10" Y FINISH FLOOR ot ELEV. 8'-0" FLOOD ZONE a y a. .006 MIL VAPOR BARRIER ON $ CLEAN COMPACTED TERMITE TERMITE TREATMENT TREATED FILL. d o (3)#5 RODS GOUT. ON REQUIRED CHAIRS WITH CORNER BENDS ELEV.6'-4" FINISH SLAB OL ELEV. 8'4' FLOOD ZONE --�Y \_ (3) #5 RODS CONT. ON CHAIRS WITH CORNER BENDS �I FLOOD ZONE _ II - - III - III - H111 I° I .006 MIL VAPOR BARRIER ON a •• CLEAN COMPACTED TERMITE , TREATED FILL. ELEV. 6'-0" FINISH SLAB #5 RODSON C 1 -8 CHAIRS WITHH CORONT.NER CORNEE R BENDS SCALE- 3/4' = 1'-0' HANDRAIL 1 1/4" Z WITH GRIP. EXTERIOR M 36" HIGH 4" O.C. ION THIS STRUCTURE HAS BEEN DESIGNED AND REVIEWED FOR COMPLIANCE OF FBC 1606.1.4 FOR ONE OF THE FOLLOWING: INTERNAL WIND PRESSURE WINDBORNE DEBRIS PROTECTION i IMPACT RESISTANCE GLAZING �07Sp')'7r mt.) - U/ n v ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR CO PLI CE REVIEWE B DATE 10 PLA S AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE 4A�O. TO APPROVED SEWER SYSTEM GENERAL NOTES: 6. CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF 1. CONSTRUCTION SHALL FOLLOW THE FLORIDA BUILDING CODE AS GROUTED CELLS AT EACH LIFT OVER 4'-0" HIGH. CLEANOUTS ADAPTED BY THE COUNTY AND ALL APPLICABLE AMENDMENTS, SHALL BE SEALED AFTER CLEANING AND INSPECTION, AND 2. BUILDER SHALL COORDINATE ALL THE WORK OF ALL TRADES. BEFORE GROUTING. 3. BUILDER SHALL REVIEW DRAWINGS IN THEIR ENTIRETY BEFORE FOUNDATION NOTES: STARTING WORK. THE BUILDER SHALL ACCEPT FULL RESPONSIBILITY FOR ANY ERRORS OR OMISSIONS NOT REPORTED 1. AFTER STANDARD CLEANING AND GRUBBING HAS BEEN IMMEDIATELY IN WRITING TO THE ARCHITECT. BACK CHARGES WILL COMPLETED AND APPROVED, APPLY VIBRATORY COMPACTOR NOT BE ACCEPTED. DO NOT SCALE DRAWINGS. WITH A MINIMUM OF FOUR PASSES TO THE EXISTING GROUND, 4. BUILDER IS RESPONSIBLE FOR ADEQUATE BRACING OF STRUCTURAL 2. FLOOR SLAB TO BE 4" THICK POURED CONCRETE SLAB WITH OR NON-STRUCTURAL MEMBERS DURING CONSTRUCTION. 6"x6" #10/10 W.W.M. OR FIBER MESH ON 0.006 VISQUEEN (OR 5. ALL WINDOWS AND DOORS SHALL BE CAULKED AND WEATHER EQUAL) ON CLEAN WELL COMPACTED FILL PRE TREATED FOR STRIPPED. WINDOW UNITS SHALL DISPLAY LABELS SHOWING TERMITES. WWM SHALL BE LOCATED IN THE MIDDLE TO UPPER COMPLIANCE WITH THE F.B.C. CHAPTER 13 ENERGY EFFICIENCY HALF OF THE SLAB DEPTH AND MUST BE SUPPORTED AT 3'-0" SECTION II. ALL CONSTRUCTION IN BROWARD AND DADE COUNTIES O.C. EACH WAY WITH APPROVED MATERIALS. SHALL COMPLY WITH WITH THE HIGH VELOCITY HURRICANE ZONE 3. SLAB AND FOOTING CONCRETE SHALL BE A MINIMUM OF 2500 (HVHZ) SECTIONS OF THE F.B.C. P.S.I. @ 28 DAYS. 4. SLABS SHALL NOT BE LOADED UNTIL 12 HOURS HAS ELAPSED. 5. ALL REINFORCING BARS, DOWELS AND TIES SHALL CONFORM PLAN NOTES: WITH ASTM - 6115 AND SHALL BE FREE OF DIRT OR MUD. 1. PROVIDE 3" STEEL POST OR BOLLARD OR TIRE BUMPER IN FRONT 6. ALL REINFORCING SHALL BE PLACED AND SECURELY TIED IN OF ALL EQUIPMENT (HVAC, EHW, WASHER/DRYER) LOCATED IN THE PLACED SUFFICIENTLY AHEAD OF PLACING CONCRETE TO GARAGE AT FLOOR LEVEL PER F.B.C. MECHANICAL CODE. ALLOW INSPECTION AND CORRECTION, IF NECESSARY, 2. ALL GLAZING WITHIN 24" (48" IN HVHZ) AND PARALLEL TO A DOOR WITHOUT DELAYING THE CONCRETING OPERATION. SHALL BE TEMPERED. ALL WINDOWS, MIRRORS OR GLASS 7. ALL DOWELS & VERTICAL BARS ARE #5 UNLESS NOTED AS ENCLOSURES AT OR WITHIN 36" . F TUBS AND SHOWERS WITH #4 SILLS LESS THAN 60" ABOVE FLOOR SHALL BE TEMPERED. ALL # BARS: 25" LAP SPLICE W/ 10" HOOK GLASS IN SIDELIGHTS, SLIDING GLASS DOORS AND FRENCH DOORS #7 BARS: 35" LAP SPLICE W/ 14" HOOK SHALL BE TEMPERED. 8. SPLICES SHALL BE 48 BAR DIAMETERS AND CONTINUOUS 3. EGRESS WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT AROUND ALL CORNERS AND CHANGES IN DIRECTION. CORNER BARS SHALL BE 48 BAR DIAMETERS EACH WAY. THE USE OF TOOLS. EGRESS WINDOWS SHALL HAVE A MINIMAL NET 9, IMBED DOWELS 6" IN CONCRETE. OPENING OF 24" HIGH, 20" WIDE, AND MIN, NET AREA OF 5.7 S.F. FOR 10. VERTICAL BARS TO EXTEND TO TOP STEEL WITH HOOK. 2nd FLOOR WINDOWS AND 5.0 S.F. FOR 1st FLOOR WINDOWS. THE (SEE NOTE 7 FOR SIZES OF HOOK) BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR, LATCH AT 54" A.F.F. MAX. IN HVHZ AREAS WHERE THERE IS CONCRETE NOTES: MORE THAN A 4'4' DROP, THE SILL SHALL BE NO LESS THAN 36" A.F.F. 1. CONCRETE SHALL CONFORM TO ASTM C94-94 AND SHALL HAVE OR PROVIDE AN APPROVED SAFEGUARD. 2500 PSI COMPRESSIVE STRENGTH IN 28 DAYS (UNLESS NOTED 4. IN HVHZ AREAS PROVIDE HURRICANE SHUTTERS AS PER F.B.C. OTHERWISE). ALL CONCRETE WORK SHALL BE IN ACCORDANCE SECTION 2413 UNLESS THE EXTERIOR WALL COMPONENTS OF THE WITH ACI 318-99 AND ACI 301-99. ALL CONCRETE MASONRY ENCLOSED BUILDING HAS SPECIFIC PRODUCT APPROVAL TO WORK SHALL BE IN ACCORDANCE WITH ACI 530-99. PRESERVE THE ENCLOSED BUILDING ENVELOPE AGAINST IMPACT 2. MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE: LOADS AS SET FORTH IN CHAPTER 16. SLABS ON VAPOR BARRIER - 3/4" 5. PICKETS AT STAIRS, LANDINGS & BALCONIES SHALL BE SPACED BEAMS AND COLUMNS - 1 1/2" TO PREVENT PASSAGE OF A 4" DIAMETER SPHERE. FORMED CONCRETE BELOW GRADE - 2" 6. ALL DWELLING ROOMS MUST HAVE HVAC RETURNS. RETURNS MAY UNIFORMED CONCRETE BELOW GRADE - 3". BE DUCTED. JUMPERS OR TRANSFER GRILLES. 3. REINFORCING STEEL: GRADE 60 (FY = 60.000) ASTM A615-94. 7. A/C PADS SHALL BE MIN. 6" THICK, BE A MINIMUM 4'-0" x 4'-0" PAD 4. DOWELS COLUMN AND WALL REINFORCING TO FOOTING WITH FOR A SINGLE UNIT AND MINIMUM 4'-0" x 9'-0" PAD FOR DOUBLE UNIT. SAME SIZE AND NUMBER OF DOWELS AS VERTICAL BARS 8. HVAC MUST BRING A 4"0 FRESH AIR INLET INTO SYSTEM. ABOVE. 5. REINFORCING STEEL SHALL BE LAPPED 48 BAR DIA. MIN. MASONRY NOTES: WHERE SPLICE) AND SHALL BE WIRED TOGETHER. PROVIDE CORNER BARS SAME SIZE AND NUMBER AS HORIZONTAL BEAM 1. CONCRETE UNITS TO BE ASTM C 90-90, ASTM GRADES NI OR Nil. REINFORCING AT EACH FACE. LAP 48 BAR DIA. MIN. PROVIDE PRECAST LINTELS AS NECESSARY. (fm = 1500 PSI) 2. MORTAR TYPE M PER ASTM C 270-92, STRUCTURE FIRE PROTECTION IN ACCORDANCE 3. CONCRETE FILL WITH SBCCI 1997 STANDARD BUILDING CODE 709 A. CELLS LINTELS AND BOND BEAMS WHERE SPECIFIED SHALL CALCULATED FIRE RESISTANCE BE FILLED W/3000 PSI PEA GRAVEL CONCRETE, B. THE MIX DESIGN SHALL BE APPROVED BY THE ENGINEER, C. ALL CONCRETE SHALL BE OF A FLUID CONSISTENCY, WHICH THE ONE HOUR FIRE RATED ASSEMBLY PROPOSED IS THE MEANS THAT THE CONSISTENCY SHALL BE AS FLUID AS ADDITION OF THE MATERIAL IDENTIFIED AS "DENS -GLASS GOLD" POSSIBLE FOR POURING WITHOUT SEGREGATION OF THE WHICH IS RATED FOR ONE HOUR FIRE PROTECTION. SEE CONSTITUENT PARTS. ATTACHED CUT SHEET FROM THE MANUFACTURER AND LISTED 4. REINFORCING BELOW THE WINDOW OPENINGS OF THE SIDEWALLS ARE LESS THAN 10% OF THE SIDEWALL AREAS. VERTICAL: A. ASTM A615-94 PER REINFORCING SECTION (GRADE 60). RIGHT SIDE WINDOW OPENINGS = 3.8% B. VERTICAL REINFORCING STEEL SHALL HAVE A MINIMUM LEFT SIDE WINDOW OPENINGS = 3.8% CLEARANCE OF ONE-HALF INCH FROM THE MASONRY. QUOTING FROM THE CUT SHEET: C. VERTICAL REINFORCING EACH SIDE OF ANY OPENING, IF REQUIRED, SHALL BE CONTINUOUS TO THE TIE BEAM. PRECAST LINTELS SHALL HAVE OPENINGS TO ALLOW FIRE PROTECTION "DENS -GLASS GOLD" IS NON-COMBUSTIBLE REINFORCING BARS TO CONTINUE UNINTERRUPTED. (AS TESTED PER ASTM E-136). SO IT OFFERS BETTER PROTECTION AGAINST BURNING TEST (PERFORMED IN ACCORDANCE WITH 5. VERTICAL CELLS FOR MASONRY TO BE GROUTED SHALL HAVE ASTM E-84) SHOW DENS -GLASS GOLD PANELS PROVIDE ZERO VERTICAL ALIGNMENT SUFFICIENT TO MAINTAIN A CLEAR, FLAME SPREAD AND ZERO SMOKE DEVELOPMENT. TEST OF 5/8" UNOBSTRUCTED CONTINUOUS CELL, DENS -GLASS GOLD FIRESTOP. TYPE'X' (PREFORMED IN ACCORDANCE WITH ASTM E-191) QUALIFIES FOR A ONE HOUR FIRE RESISTANT CONSTRUCTION (UL 337). MY SIGNATURE AND SEAL HEREBY CERTIFIES THAT THIS MATERIAL AREA SCHEDULE APPLIED TO THE WALL WILL COMPLY WITH THE INTENT OF THE ONE HOUR FIRE RATING REQUIREMENTS. 1st FLOOR AREA CARPORT STORAGE ROOM 620 203 211 S.F. S.F. S.F. TOTAL 1st FLOOR AREA 1,034 S.F. 2nd FLOOR AREA FRONT PORCH 370 35 S.F. S.F. TOTAL 2nd FLOOR AREA 405 S.F. TOTAL FLOOR AREA 1,439 S.F. LIVING AREA UNDER .AIR 990 S.F. CERTIFICATION AND SEAL I HEREBY CERTIFY THAT THIS PLAN AND SPECIFICATION WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULYREGISTERED ARCHITECT OR ENGINEER UNDER THE LAWS OF THE STATE OF FLORIDA AS SIGNIFIED BY MY (HAND AND SEAL. 15'-221" . I Q• 0 (2) FULL SPAN PRE-FAB & PRE-ENGINEERED \ WOOD GIRDER TRUSS BY TRUSS MANUFACTURER. GIRDER TO BE DESIGNED FOR A UNIFORMLY SIN • \ 0 O in N K F \ K O • O 5 -516 LL X \ a w w 0 0 n 12" DEEP 2"x4" FLOOf�t TRUSS 16" O.C. • D O O 15'-2„ 7,-0„ I� L 22P-211 �. �,�. d �.� • �. �. o • r LUUN MAMNU rLAN SCALE:1/4' = T-0" ALL HEADERS ARE 2"x8" TOP & BOTTOM FLOORS. (SEE SHEET 3) OSLEEPING ROOMS PROVIDE AN EGRESS NDOW WITH A NET CLEAR OPENING SG. FT FOR GROUND FLOORS, SaE`T SQ Ff. FOR UPPER FLOORS, OPENINGS NOT BE LESS THAN 24'H OR INGS MORE THAN 44" ABOVE FLOOR ARCHITECTUAL SHINGLES OVER 30# FELT PAPER ATTACHED TO 5/8" COX PLYWOOD NAIL 8D 4" ON SEAM, 6" IN FIELD ON ENGINEERED TRUSSES 24" O.C. 12 ROOF SLOPE 3 SIMPSON MTS16 EVERY RAFTER NAIL 14 - 10D \ F 1000# UPLIFT DBL. 2" X 6" TOP PLATES W/ DRIPEDGE OVER 2"x6" SUB SIMPSON SP2 EACH STUD FASCIA W/ ALUM. FASCIA& NAIL 12 - IOD EACH, 890# UPLIFT VENTED VINYL SOFFIT IMF\\_ 5/8" DRY WALL TYPE'X' (TYPICAL) ACCORETTE STUCCO ON 5/8" DENS GLASS ON "TYVEK" ON 1/2" CDX NAILED 4" ON SEAM & 8" IN FIELD ON 2" X 6" WOOD STUDS 16" O.C. W/ R-19 INSUL. ese A HS✓4% � �UF� 0 /AFQAyTTOgNy 1 p9pF �'O6fA� Ss49y/N pFC �&0 o, 0)k c o�aT Fs , THETA 40 SIMPSON 16" O.C. Z X6" SOLE PLATE P.T. EMBEDDED 4" MOLDING NAIL 10 - 10D x 1 1/2", 1810#UPLIFIFT -- - - -- F____ ____---- _____ _____ _____. FRAMING NOTES: 1. THE TRUSS LAYOUT SHOWN ON THESE PLANS ARE SCHEMATIC IN NATURE. HOWEVER, THE SUPPORTING SUPERSTRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THAT THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL THE FINAL TRUSS DESIGNERS LAYOUT. 2. FINAL SIGNED AND SEALED ENGINEERED TRUSS DESIGN MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW. TRUSS DESIGNERS MUST PROVIDE ALL TRUSS CONNECTIONS AS PAST OF THE DESIGN, 3. TRUSS MANUFACTURER SHALL SUBMIT THREE (3) COPIES OF SHOP DRAWINGS AND ENGINEERING CALCULATIONS SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER, OF THEIR ROOF TRUSS DESIGN FOR REVIEW INCLUDING TWO (2) COPIES FOR ARCHITECTS REVIEW PRIOR TO FABRICATION. REVIEW OF TRUSS SHOP DRAWINGS IS A COURTESY BY THE ARCHITECT AND IN NO WAY RELIEVES THE TRUSS MANUFACTURER OF HIS RESPONSIBILITY TO PROVIDE A LAYOUT THAT FULLY INTEGRATES WITH THE ARCHITECTS SUPERSTRUCTURE. IF THERE IS ANY CONFLICT OR ADDITIONAL STRUCTURE NEEDED, THE TRUSS COMPANY SHALL NOTIFY THE ARCHITECT IN WRITING OF THE SPECIFIC AREAS OF CONCERN. /N tRlj�7 ne 401NO0 1 Dr/L°;F A��/��E F EF(®A/pA ARCHITECTUAL SHINGLES OVER 3q# FELT PAPER ATTACHED TO 5/8" CDX PLYWOOD NAIL 8D 4" ON SEAM, 6" IN FIELD ON ENGINEERED TRUSSES 24" O.C.. 12 ROOF SLOPE 3 Q. TOP I R-30 BATT. DBL. 2" X 6" TOP PLATES W/ SIMPSON SP2 EACH STUD NAIL 12 - 10D EACH, 890# UPLIFT 5/8" DRYWALL TYPE'X' 2"X6" SOLE PLATE P.T. 314" T & G PLYWOOD GLUE & SCREW TO 2" X 8" WOOD JOISTS MOLDINI 16" O.C. W/ R-19 INSULATION IN CARPORT AREA USE 1/2" CDX PLYWOOD W/ DENS -GLASS & STUCCO FINISHED. (2) 8"x8"x16" BEAM BLOCK (2) #50 CONT. 8"x8"x16" CONC. BLOCK ___ ___ -______-_____ 4. TRUSSES TO BE DESIGNED TO CARRY LOADS OF ATTIC AHU AND MISC. EQUIPMENT. COORDINATE LOCATIONS WITH BUILDER PRIOR TO FABRICATION AND INDICATE ON TRUSS DRAWINGS. THE BUILDER SHALL BE RESPONSIBLE FOR THE COMPLETE COORDINATION BETWEEN THE TRUSS DESIGN AND AIR CONDITIONING DESIGN REQUIREMENTS, 5. ALL INTERIOR LOAD BEARING PARTITIONS TO BE CONSTRUCTED WITH CLIPS, TOP AND BOTTOM EACH STUD, AS PER CODE. 6. STRUCTURAL WOOD AND TIMBER FRAMING SHALL CONFORM TO THE'TIMBER CONSTRUCTION MANUAL" AS PUBLISHED BY THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION. 7. ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED, PROVIDE AN APPROVED MOISTURE VAPOR BARRIER BETWEEN THE CONCRETE OR OTHER CEMENTITOUS MATERIALS AND THE WOOD AS PER CODE. 8. TRUSS MANUFACTURER SHALL DESIGN TRUSSES TO COMPLY WITH ALL SUPERIMPOSED WIND LOADS PER F.B.C. 2001, SIMPSON MTS16 EVERY RAFTER NAIL 14 - 10D 1000# UPLIFT (TYPICAL) SCANNED I* i_uce 001301 DRIPEDGE OVER 2"x6" SUB FASCIA W/ ALUM. FASCIA & VENTED VINYL SOFFIT ACCORETTE STUCCO ON 5/8" DENS GLASS ON "TYVEK" ON 1/2" CDX NAILED 4" ON SEAM & 8" IN FIELD ON 2" X 6" WOOD STUDS 16" O.C. W/ R-19 INSUL. ob F.F.E. 15'-1" 2nd FLOOR 1�`HETA40 SIMPSON 16" O.C. EMBEDDED 4" NAIL 10 - 1OD x 1 1/2", 1810# UPLIFT _ ELEV. B'-O" FLOOD ZONE z z 0 W d Ll v, LLI m V 0) ZZ � U Ll QJ d z w L �� I— �W NaLU p{ o<> z 0ZU �o oLL O W w czL11 tnmO LL fl U Q J �Qy Lj > > y LL cd —j Z Z O 0 a. � 0 0) a v 3:° >W 0 > N 0 oy LL a-9 A 1 F-7 ��/® L F F Gzl I C7 O Z a u � LiO U �yy E- L h,W 3LLJ R gDRAWN BY1 CHECKED BY DATE 02-08-05 SCALE 1/4"-1'-0" JOB No. 04-197 SHEET SHEETS OF j 8"x8"x16" CT C. BLOCK 7x4" MATERIAL P.T. OR SPRUCE, TAPCON TO BLOCK W/ (3) 3/16"x2 1/2" TAPCONS OR SPIKE WA 12d NAILS. 1/2" WEDGE ANCHOR EVERY 48" O.C. ENGINEERED TRUSS @ 24" O.C. Q ? +45.50 =----- ---------- ------------- =-- -------'------------------- -- ---� -- -49.55 it . r------------- ______.-________-____ _ SCALE: 1/4" = 1'-0" 5G BY �t i_�1CaB'�Ot111� � M�.j- p gyp_ .gip 1111G ll u ELL V AT M SCALE:1/4" =1'-0" rSFSF a, �a � •< gq�CSU P<4N`ggNO gFQNigFO Fprr p A`� Pgnp i^r Cp yBfiNF sy',1' 4 yoo SFo �pAR MP4yFSp�gy/N3p�CCrp n7o w pp, 'a✓��p�.�J p pga�grs�4r =2 Oz N = � J Q +45.50 -59.40 il I III ai I I IMF! I I r FRONT ELSE V AM M SCALE: 1/4" =1'-0" ROOF CONNECTOR CHART TRUSS ENDS UPLIFT LOADS SIMPSON CONNECTOR EA. END ANCHORS EA. CON. ALL A & B - MTS 16 1000# 14-10D EVERY RAFTER WINDOW FRAMING & HE � DDERD�TtiI� V4 E ;H SLAB ELEV. 6'-0" ELE V AMN SCALE: 1/4" =1'-0" DOOR & WINDOW WIND LOAD PRESSURES 140 MPH - EXPOSURE "C" = +45.5 / -59A PSF (EDGE ZONE)I 4 z 0 w x w e. a VJ Lu ` ,m V 00 > Z� z W �� �p u�W W w Oo Q g �g6 z u 1 5J zo o" o u- 0w ~ a w a z u- 0.. 0 off$ J J m J N uj D n F-- 2 O O Q O 3 a O ai F' U a � � � W vi N N LL rr .I...L 0- L.L 4=4 u � a W E-. � a z 0 w o E 0 � a ® o L Q Li DRAWN BY i1>»oo7S o CHECKED BY DATE 02-08-05 SCALE 1/4"-1'-0" .1oB N11 0 4 —19'7 SHEET SHEETS 3 EE 4 A/C NOTES 1. DUCT WORK MAIN LINE SUPPLY TO BE FIBERGLASS HARD BOARD R-6 MIN. 2. DUCT BOARD INTERNAL SURFACE TREATMENT TO BE RESISTANT TO FUNGUS GROWTH. 3. ALL DUCT WORK ABOVE CEILING TO BE R-6. 4. EACH AIR HANDLER UNIT TO BE EQUIPPED WITH A HUMIDSTAT TO REMOVE MOISTURE TO LESS THAN 50%. 5. A/C FEED WIRING TO BE INSTALLED BY ELECTRICAL CONTRACTOR. AIR CONDITIONING SCHEDULE UNIT# A/C HEATSTRIP AIR HACFDMER NAME CAT.# VOLT I PHASE VA I WATTS TONAGE KVA MFG. 1 2 1/2 10 KVA 1200 230 1 3750 ELECTRICAL NOTES: 1. CONTRACTOR SHALL VERIFY WITH F.P. $ L. THE LOCATION OF SERVICE AND SHALL LOCATE METER & PANELS AS REQUIRED. 2. ALL WIRE SHALL BE THHN COPPER, UNLESS NOTED OTHERWISE. 3. PROVIDE DISCONNECT SWITCH OF SIZE AS REQUIRED BY LOAD AND UNITS. 4. PROVIDE NON -FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIPMENT AND AT PUMPS NOT VISIBLE FROM CIRCUIT BREAKER PANEL AND AS PER MANUFACTURER RECOMMENDATIONS. 5. PROVIDE GFI BREAKERS FOR ALL BATHROOMS, GARAGE AND EXTERIOR OUTLETS AS SHOWN ON PLANS. 6. ELECTRICAL FIXTURES, TRIM AND APPLIANCES BE UL APPROVED AND AS SELECTED BY OWNER. 7. PROVIDE PRE -WIRED TELEPHONE OUTLETS AS SHOWN ON PLAN. 8. PROVIDE PRE -WIRED T.V. OUTLETS FOR CABLE AS SHOWN ON PLANS. 9. DEDICATED CIRCUITS SHALL HAVE NO MORE THEN 6 DUPLEX RECEPTACLES. 10. IN KITCHENS, DINING ROOMS AND BATHROOMS, RECEPTACLE OUTLETS FOR COUNTER SPACES SHALL BE GFCI PROTECTED ACCORDING TO NEC 210-8(a). 11. ALL CLOSET LIGHTING SHALL COMPLY WITH NEC SEC, 410.8. 12. SMOKE DETECTORS SHALL BE CONNECTED TO KITCHEN OR BATH LIGHTING CIRCUITS AHEAD OF SWITCH AND HAVE SELF CONTAINED BATTERY BACK-UP. DETECTORS SHALL BE TANDEM WIRED SO ALL DETECTORS SOUND SIMULTANEOUSLY. 13. PREWIRE FOR GARAGE DOOR OPENER SENSOR. 14. PROVIDE ARC FAULT-INTERRUTER PROTECTION FOR ALL DWELLING ROOM RECEPTACLES. 15. SMOKE DETECTORS REQUIRED ON ALL HVAC UNITS WITH 2O01 CFM OR MORE. MECHANICAL NOTES: 1. ALL HEATING, AIR CONDITIONING, REFRIGERATION AND VENTILATION EQUIPMENT SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE "FLORIDA BUILDING CODE MECHANICAL" AND CHAPTER 28 OF THE FLORIDA BUILDING CODE. (2) 5/8" RODS 8' LONG V APART U.G. SERVICE [31 1 /0 THW CU. IN. 1-112" CONDUIT LO 150 AMP MAIN DISC BOND TO STEEL [3) 1/0 THW CU. IN. 1-1/2" CONDUIT 1201240V 10 3W 150 AMP PANEL ALL ELECTRICAL I.A.W. CURRENT "N.E.C." INCL. GFI OUTLETS. ALL WIRING TO BE COPPER. A/C DISC, SIZE AS PER A/C MFG'R SPECS ELECTRICAL LOAD CALCULATIONS 1,439 S.F. @ 3 VA 4,317 TWO 20 AMP APPLIANCE CKTS 3,000 LAUNDRY 1,500 DRYER 4,500 RANGE 12,000 DISPOSAL 1,000 WATER HEATER 4,500 DISH WASHER 1,200 REFRIGERATOR 900 TOTAL VOLT/AMPS = WATTS 32,917 FIRST 10 KVA 10,000 AC HEAT STRIP 10,000 REMAINDER AT 40% 5,167 TOTAL 25,167 USE AMPS = 25,167/240 104.9 AMPS USE 150 AMP SERVICE ALL BEOROOMS OUTLETS ARE REQUIRED TO BE ACCI PROTECTED (2002) NEC <^ PROVIDED ELECTRIC SMOKE I DETECTLORS P ALL SLEEPING WITH BATTERY BACK D STAIR L At4DINGS AREAS ANHpT THE ACTIVATION VoRED SOCTOR WILL ACTIVATE ALL - OF ANY DETE ELECTRICAL SYMBOLS ,I{ OT PZEA RECEPTACLE 4 KEY PAD LIGHT CUG.. MOUNTED B DUPLEX RECEPTACLE AT BASE J O JUNCTION BOX INCONDESCENT LIGHT WALL MOUNTED �C DUPLEX RECEPTACLE AT 8" ABV. COUNTER nTV T TELEVISION JACK PRE -WIRED \ / HI -HAT CL'G. MOUNTED a O DUPLEX RECEPTACLE FLUSH IN FLOOR ® 220 V. RECEPTACLE AT 12" A.F.F. � l \ /VP HI -HAT VAPOR PROOF (jGFI DUPLEX RECEPTACLE GROUND FAULT T O HVAC THERMOSTAT I1 CO3 F.P.&I. METER &DISC. DUPLEX RECEPTACLE TOP REC. SWITCHED "r INTERCOM AT BO"A.F.F. BREAKER PANEL �WP DUPLEX RECEPTACLE WATERPROOF PH . TELEPHONE OUTLET AT 12' A.F.F. ® EXHAUST FAN UC luv DUPLEX RECEPTACLE UNDER COUNTER PH a TELEPHONE OUTLET FLUSH IN FLOOR EXHAUST FAN Wl LIGHT SWITCH SINGLE POLE SPEAKER IN CUG. FLUORESCENT LIGHT FIXTURE 3 SWITCH THREE WAY n SECURITY LIGHTS DOOR BELL 4 SWITCH FOUR WAY O SD SMOKE� DETECTOR �( :l CHIMES R SWITCH RHEOSTAT Il SWITCH DISCONNECT $$D SWITCH DIMMER /� tj PADDLE FAN W/OR W/O LIGHT $K SWITCH KEYED .5r �NED StLucieCounty 4" =11-0" Ilesea 9 4 � ,TTgNOq�` P AFD O41V-oSzo c M; 44 WjN SSoy/,v 4'044Sp�A SAS DNS o9t App 04,ej �S 1T gCszoi USN Op�C /OT�eF4O,�� z 0 5 w x w E a Ld U 00 rn z Z LLI d _ N �� x 2 LU N W J U 0 U CD mo U TTT1— x Ly Q F y F U 06 J J n J Li m (n ^[ Z 20) ILL O00� ry ^ IL L yf1 c F=1 �P�l Em�E-44 4 FOE � d� Z O � _4 E--I W E- O � Z O w o co lu0 Z a oIII IIuII'IL1 Z 1� LLI (� Li Q Illull� O v� � Li Q DRAWN N/j BY; d®}QO Mffi��//.F. CHECKED BY� DATE 02-08-05 SCALE 1/4„-1,-0" JOB NO 04-197 SHEET SHEETS 4 UE 4 SCANNED -F 1= -- - 14 14 79 wu sxs sxs X8 21'4"12 AA $A 01 of TRUSS 'FT4" 60'0°15 M LO '10"3 1271 TRUSS 'FT8' P I P +2 +2 +2 +2 21 + 2 +E' m �, V. r) ch 14 11'3"12 11'3012 3 � '2"6 5'1"6 5'1"6 '2"6 4X4 1.534 1 5X4 3x� 3'1 13 A1) 3X5(A1)Li 3X5 5X7 21'6" /4" X 16" DEEP 3100 SP 1/4" 8 1/4" T10"13 I— O 9"13 J �'10"13 �� 3X5(A1) i TRUSS "AB" 1.5 0'4"12 0'4"12 4X6(R) Tg 7 IA6 °a ph BI, IM `1:fl0 °jD 0'4"1 TRUSS 'A2' FILE COP 2' R , S ajf TS 0 N4y4 AROP05 f MAYS EBYR/to/N5P RRECpE0SW ORK COMPO'1INAS4RYINOR ERTp THAT ",441JGgpe, 000F5. F�'JT�y16�4, y,C+ c= AJ o 0 2 U �J a L o _ d 94 ; z; if LAJ E -F 0 E- c LU LU w c _T m p, .so i N . c ZCIO cr3ac5 wa S `c U TRUSS PLACEMENT SCHEDULE BY; MELVIN HARRISON ROOF & FLOOR TRUSS SYSTEMS 4175 MARTIN HIGHWAY PALM CITY, FL. 34990 OFF, (772) 286-3700 FAX (772) 288-4234 NOTED TRUSSES SHOWN ON THIS PLACEMENT PLAN ARE A COMPONENT PART OF THE BUILDING AND SHOW TRUSS LOCATIONS PROPER ERECTION, TEMPORARY AND PERMANENT BRACING DESIGN ARE THE RESPONSIBILITY OF THE BUIL➢ING DESIGNER OR HIS ENGINEER. LATERAL BRACING SHOWN ON THE INDIVIDUAL TRUSS DRAWINGS MUST BE PLACED DURING ERECTION PROCEDURE. AUTH❑RIZATI❑N AGREEMENT TRUSSES CANNOT BE FABRICATED UNTIL THIS AGREEMENT HAS BEEN SIGNED AND RETURNED TPE LEGAL ➢ESCRIPTI13N OF THE PROPERTY WHERE THE TRUSSES WILL BE INSTALLED IS: THE UNDERSIGNED ACKNOWLEDGES AND AGREES, 1. TRUSSES VILL BE MADE N STRICT ACCORDANCE WITH IRIS LAYOUT, WHICH 1S THE SOLE AUTHORITY FOR DETERMINING SUCCESSFUL FABRICATION GF THE TRUSSES 2. ALL DIMENSIONS IN THIS LAYOUT HAVE BEEN VERIFIED BY THE UNDERSIGNED. a UNLESS WRITTEN NOTICE IS PROVIDED BY CERTIFIED NAIL TO W. KOST, INC. WITHIN TEN (10) DAYS OF DATE Or DELIVERY THE lDERSIGNED AGREES THAT NO BACKCHARGES WILL BE ALLOWED IN TIE EVENT SUCH WRITTEN NOTICE IS FURNISHED, W. HOST, INC. SHALL HAVE THREE 0 BUSINESS DAYS IN WHICH ID BEGIN REPAIRS REWIRED, OR MAKE A.RRMEEMEMIS TO HAVE REPAIRS DOE OR TO SUBSTITUTE OTHER TRUSSES, AT W. KIST, 1NC OPTION, 4. THE UNDERSIGNED ACKNOWLEDGES RECEIPT OF 'NO-91' TRUSS PLATE INSTITUTE. 5. DELIVERY IS TO JOB SITE IT IS THE BUYERS RESPONSIBLITY TO MAKE THE JOB SITE SUITABLE FOR DELIVER W. KOST, INC. HAS THE SOLE AUTHORITY TO DETERMINE THE SUITABILITY IF THE .JOB SITE OR A PORTION IF THE .AB SITE FOR DELIVERY. V. MOST, INC. WILL BE RESPONSIBLE FIR BUMP DELIVERY ONLY, THE BUYER IS RESPONSIBLE FOR ANY ADDITIONAL DELIVERY EXPENSES IF W. KEST, INC. HAS TO REDELIVER BECAUSE JOB SITE IS NOT PREPARED FOR DELIVERY OF TRUSSES. BUYER WILL ALSO BE RESPONSIBLE FOR ANY TOWING CHARGES DUE TO SITE CONDITIONS. 6. PRICE AS SHOWN IN PARAGRAPH 7 IS SUBJECT TO CHANGE IF ANY CHANGES ARE MADE TO THIS LAYOUT. 7. THIS IS A PURCHASE DRIER TO V. MOST, INC. ]IF THE SUM IF B Mm INCLUDES SALES TAX, INVOICE VILL BE MADE ON DELIVERY AND VILL BE PAID WITHIN TERNS AS REWIRED BY W. KOST, INC, MANAGEMENT, INVOICE MAY BE MADE AT SCHEDULED DATE Of DELIVERY IF BUYER CANNOT ACCEPT DELIVERY OF FABRICATED TRUSSES. THE UNDERSIGNED AGREES TO PAY W. KOST, INC. REASDNABLE ATTOMEY'S FEE FOR COLLECTIONS. IN THE EVENT PAYMENT IS NOT RECEIVED WITHIN TERMS, 1 1/2% PER MOTH SERVICE CHARGE VILL BE AM TO ALL OUTSTANDING BALANCES B. SIGNITURr OR INITIALS ANYWHERE ON THIS SHEET CONSTITUTES AGREEMENT TO ALL ITEMS HEREIN 9. IN THE EVENT OF ANY LITIGATION CONCERNING THIS AGREEMENT, THE ITEMS FURNISHED HEREUNDER OR PAYMENTS REFERRED TO HEREIN, THE PARTIES AGREE THAT THE SOLE VENUE FOR ANY SUCH ACTION WILL BE MARTIN COUNTY, FLORIDA, DATE: , aL— D❑ NOT CUT OR ALTER THESE TRUSSES IN ANY WAY WITH❑UT WRITTEN PERMMISI❑N FROM A W. KOST INC, REPRESENTATIVE ROOF DESIGN LOADS (PSF) TOP CHORD LIVE 20 TOP CHORD DEAD 15 B❑T, CHORD LIVE 10 B❑T, CHORD DEAD 10 TOTAL DESIGN LOAD 55 STRESS INCREASE 1.25 WIND LOAD 140 ASCE 7-98 CATEGORY IC" STATUS CLOSED NInTC. THE ENGINEERED TRUSS DRAWINGS HAVE PRIORITY OVER THE TRUSS LAYOUT, SEE DRAWINGS FOR GIRDER PLYS AND REACTIONS. MULTIPLE PLY TRUSSES MUST BE NAILED OR BOLTED TOGETHER (PER ENG, TRUSS DWGS,) BEFORE THEY ARE ERECTED. TRUSS TO TRUSS CONNECTORS THAT EXCEED THE STANDARD HANGER SPECS. ARE THE RESPONSIBILITY OF THE BUILDER. DUE TO ABNORMALITIES IN DESIGN, SLABS, BEAMS, AND/OR LUMBER, W. KOST WILL NOT BE RESPONSIBLE FOR ANY DEFLECTI❑N IN GIRDER TRUSSES OVER 20'-0' IN LENGTH ❑R COMMON TRUSSES OVER 30'-0' IN LENGTH!!! rRuss LA Your FOR CUSTOMER PREMIER JOB NAME C❑NST, & REM❑D, PERRINE LOT/BLK/SECT LOT 390-2 ADDRESS CITY RES, NETTLES ISLAND JENSEN BEACH, FLA, PLAN SCALE: 1/4'=1'0" MEL\03-22-05\F:\ALPINE\JOBS\2733\2733.DWG