Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ICC-ES-EVALUATION REPORT 2-1-12
Y B IMES Evaluation Report �� , Imm 9 ESR-1826 Reissued February 1, 2012 report is subject to renewal in one year. www.icc-es.org 1 (800) 423-6587 1 � 61 64�0-0543 W A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND h PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: ICYNENE, INC. 6747 CAMPOBELLO ROAD MISSISSAUGA, ONTARIO L5N 21_7 CANADA (905) 363-4040 www.icynene.com EVALUATION SUBJECT: ICYNENE LD-C-50Tm (formerly known as Insulation System 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2009 Intemational Building Code® (20091 ■ 2009 International Residential Code® (201 ■ 2009 International Energy Conservation IECC) I ■ Other Codes (see Section 8.0) I Properties evaluated: ■ Surface burning characteristics I ■ Physical properties I ■ Thermal performance (R-values) ■ Ahic and crawl space installation ■ Fire resistance ■ Air permeability ■ Noncombustible construction Icynene ) IRC) Code® (2009 2.0 USES Icynene LD-C-50Tm is used to provide thermal insulation in buildings and to seal areas such as plumbing and wiring penetrations against air infiltration, in Types I, II, III, IV and Type V construction (IBC) and dwellings under the IRC. The Icynene Insulation System may be used in fire - resistance -rated construction when iristalled in accordance with Section 4.5 and in Types I through IV construction when installed in accordance with Section 4.6. 3.0 DESCRIPTION 3.1 General: Icynene LD-C-50TM is a low -density, open -cell, polyurethane foam plastic insulation and air barrier system that is 100 percent water -blown with an installed nominal density of 0.5 pcf (8 kg/m). Icynene LD-C-50 is a two - component, spray -applied product. The two components of the insulation are polymeric isocyanate (A -Component, also known as Base Seal and proprietary resin (B-Component, LD-C-50 Resin, also known as, Gold Seal. The A -Component must be stored at a temperature of 50°F (10°C) or greater, and has a shelf life of six months. The B-Component must be stored at temperatures below 100OF (37.8°C), and has a shelf life of six months. 3.2 Surface Burning Characteristics: When tested in accordance with ASTM E 84/UL 723, at a thickness of 6 inches (152 mm) and a nominal density of 0.5 pcf (8 kg/m3), Icynene LD-C-50 has a flame spread index of 25 or less and a smoke -developed index of 450 or less. Thicknesses of up to 71/2 inches (190.5 mm) for wall cavities and 111/2 inches (292 mm) for ceiling cavities are recognized based on room comer fire testing in accordance with NFPA 286, when covered with minimum 1/2-inch-thick (13 mm) gypsum board or an equivalent thermal barrier complying with the applicable code. 3.3 Thermal Resistance: Icynene LD-C-50 has thermal resistance (R-values) at a mean temperature of 75°F (24°C) as shown in Table 1. 3.4 Air Permeability: Based on testing in accordance with ASTM E 283, Icynene LD-C-50, at a minimum thickness of 3.5 inches (89 mm), is considered air -impermeable. 3.5 Intumescent Coatings: 3.5.1 CAMAX21ShelterShield Intumescent Coating: CAMAX2/ShelterShield intumescent coating, supplied by Icynene, is a water -based coating supplied in 5-gallon (19 L) pails and 55-gallon (208 L) drums and has a shelf life of six months when stored in a factory -sealed container at temperatures of 60°F (16°C) or above. 3.5.2 No Bum Plus XD: No Bum Plus XD intumescent coating is a latex -based coating supplied in 1-gallon (4L) and 5-gallon (19L) pails and 55-gallon (208 L) drums. The coating material has a shelf life of 12 months when' stored in factory -sealed containers at temperatures between 40°F (4.4°C) and 90°F (32.2°C). ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as :.ter to arty finding or other matter in this report, or as to; any product covered by the report. UM Q Copyright © 2011 1 Page 1 of 5 ESR-1826 I Most Widely Accepted and Trusted Page 2 of 5 i 3.5.3 DC 315: DC 315 intumescent coating is a water - based coating supplied in 5-gallon (191L) pails and 55-gallon (208L) drums. The coating material has a shelf life of 24 months when stored in factory -sealed containers at temperatures between 41OF (5°C) and 95OF (350C). 4.0 DESIGN AND INSTALLATION 4.1 General: The manufacturer's published installation instructions and this report must be strictly adhered to and a copy of these instructions and this evaluation report must be available on the jobsite at all times during installation. I 4.2 Application: Icynene LD-C-50 must be applied using spray equipment specified by Icynene, Inc. Icynene LD-C-50 must not be used in areas which have a maximum service temperature greater than 180°F (821C). The foam plastic must not be used in electrical outlet or junction boxes or in contact with rain or water, and must be protected from the Iweather during and after application. Where Icynene LD-C-50 is used as an air -impermeable barrier, suchl as in unventilated attic spaces regulated by IRC Section R806, the insulation must be installed at a minimum thickness of 3.5 inches (89 mm). Icynene LD-C-50 can be installed in one pass to the maximum thickness. Wherel multiple passes are required, the cure time between passes is negligible. Icynene LD-C-50 must only be installed by licensed dealers, certified by Icynene, Inc., to install Icynene LD-C-50. 4.3 Thermal Barrier: 4.3.1 Application with a Prescriptive Thermal Barrier: Icynene LD-C-50 must be separated from the interior of the building by an approved thermal barrier, such as %-inch (12.7 mm) gypsum wallboard installed using mechanical fasteners in accordance with the applicable code, or an equivalent 15-minute thermal barrier complying with the applicable code. When installation is within an attic or crawl space as described in Section 4.4, a thermal barrier is not required between the foam plastic and !the attic or crawl space, but is required between the foam and the interior of the building. Thicknesses of up toJ7'/2 inches (190.5 mm) for wall cavities and 111/2 inches (292 mm) for ceiling cavities are recognized based on room corner fire testing in accordance with NFPA 286, when covered with minimum 1/2-inch-thick (13 mm) gypsum! board or equivalent thermal barrier complying with, the applicable code. 4.3.2 Application without a Prescriptive Thermal Barrier or Ignition Barrier: The prescriptive 15-minute thermal barrier or ignition barrier may be dmitted when installation is in accordance with this section. The insulation and coating may be spray -applied to the interior facing of walls, the underside or roof sheathing of roof rafters, and in crawl spaces, and may be left exposed as an interior finish without a prescribed 15-minute thermal barrier or ignition barrier. The thickness of the foam plastic applied to the underside of the roof sheathing must not exceed 14 inches (356 mm). The thickness of the spray foam insulation applied to vertical wall surfaces must not exceed 6 inches (152 mm). The foam plastic must be covered on all surfaces with DC 315 coating at a minimum wet film thickness of 20 mils. The coating must be applied over the Icynene LD-C-50 insulation in accordance with the coating manufacturer's instructions and this report. Surfaces to be coated must be dry, clean, and free of dirt, loose debris and other substances that could interfere with adhesion of the coating. The coating is applied in one coat with low-pressure airless spray equipment. 4.4 Attics and Crawl Spaces: 4.4.1 Application with a Prescriptive Ignition Barrier: When Icynene LD-C-50 is installed within attics where entry is made only for service of utilities, an ignition barrier must be installed in accordance with IBC Section 2603.4.1.6 and IRC Sections R316.5.3 and R316.5.4, as applicable. The ignition barrier must be consistent with the requirements for the type of construction required by the applicable code and must be installed in a manner so that the foam plastic insulation is not exposed. Icynene LD-C- 50 may be installed in unvented attics in accordance with IRC Section R806.4. 4.4.2 Application without a Prescriptive Ignition Barrier: Where Icynene LD-C-50 is installed in an attic or crawl space without a prescriptive ignition barrier, in accordance with Sections 4.4.2.1, 4.4.2.2 and 4.4.3, the following conditions apply: 1. Entry to the attic or crawl space is only for the service of utilities and no storage is permitted. 2. There are no interconnected attic, crawl space or basement areas. 3. Air in the attic or crawl space is not circulated to other parts of the building. 4. Combustion air is provided in accordance with IMC Section 701. 5. Attic ventilation is provided when required by IBC Section 1203.2 or IRC Section R806, or as required, except when air -impermeable insulation is permitted in unvented attics in accordance with Section R806.4 of IRC. 6. Under -floor (crawl space) ventilation is provided when required by IBC Section 1203.3 or IRC Section R408.1, as applicable. 4.4.2.1 Attics: In attics Icynene LD-C-50 insulation may be spray -applied to the underside of the roof sheathing and/or rafters, as described in this section. The thickness of the foam plastic applied to the underside of the roof sheathing must not exceed 14 inches (356 mm). The thickness of the spray foam insulation applied to vertical wall surfaces must not exceed 5.5 inches (140 mm). The foam plastic must be covered on all surfaces with one of the coatings described in Section 3.5. The coating must be applied over the Icynene LD-C-50 insulation in accordance with the coating manufacturer's instructions and this report. Surfaces to be coated must be dry, clean, and free of dirt, loose debris and other substances that could interfere with adhesion of the coating. The coating is applied in one coat with low-pressure airless spray equipment. The coatings must be applied to a thickness as follows: ■ CAMAX 2/ShelterShield at a minimum wet film thickness of 12 mils ■ No Burn Plus XD at a minimum wet film thickness of 10 mils ■ DC 315 at a minimum wet film thickness of 8 mils The coating must be applied when ambient and substrate temperature is at least 60°F (16°C) and no more than 95°F (35°C). All other surfaces (including glass) must be protected against damage from the coating. Icynene LD-C-50 insulation may be installed in unvented attics or crawl spaces when the foam plastic is applied at a minimum thickness of 3.5 inches (89 mm) as described in this section in accordance with IRC Section R806.4. . _ti ESR-1826 I Most Widei and Trusted 3of5 4.4.2.2 Crawl Spaces: In crawl spaces, Icynene LD-C- 50 insulation may be spray -applied to vertical walls and the underside of floors, as described in this section: The thickness of the foam plastic applied to the underside of the floors must not exceed 14 inches (356 mm). The thickness of the spray foam insulation applied to vertical wall surfaces must not exceed 31/2 inches (88.9 mm). The foam plastic does not require an ignition barrier or a coating. 4.4.3 Use on Attic Floors: Icynene Icynene LD-G-50 insulation may be installed at a maximum thickness of 51/2 inches (152 mm) between joists in attic floors when covered with one of the coatings applied as described in Section 4.4.2.1. The insulation must be separatedl from the interior of the building by an approved thermal barber. 4.5 One -hour Fire -resistance -rated Assemblies: 4.5.1 Assembly 1 (Limited Load -bearing Wood Stud Wall): Minimum nominally 2-by-4 [1112 by 3'/2 inches (38 mm by 89 mm)] southern pine (G = 0.55), No. 2 grade studs spaced 16 inches (406 mm) on center with a base layer of 1/2-inch-thick (12.7 mm) wood fiber sound board installed horizontally on each face with vertical joints located over the studs, attached with 6d box nails, 2 inches (51 mm) long and spaced 24 inches (610 mm) on center along the studs, and a second layer of 5/8-inch-thick (15.9 mm) Type X gypsum wallboard installed vertically on each face, attached with 8d box nails, 21/2 inches (64 mm) long and spaced 7 inches (178 mm) on center along the studs. The stud cavity contains Icynene insulation nominally 2 inches (51 mm) thick. Axial loads applied to the wall assembly must be limited to the least of the following: I ■ 1,805 pounds (8029 N) per stud. ■ Design stress of 0.78 F'c. ■ Design stress of 0.78 F'c at a maximum le/d of 33. 4.5.2 Assembly 2 (Limited Load -bearing Wood Stud Wall): Minimum nominally 2-by-4 [11/2 by 31/2 inches (38 mm by 89 mm)] southern pine (G = 0.55), No. 2 grade studs spaced 16 inches (406 mm) on center with two layers of 1/2-inch-thick (12.7 mm) Type X gypsum wallboard installed vertically with joints staggered on each face, attached with 8d box nails, 21/2 inches (64 mm) long and spaced 7 inches (178 mm) on center along the studs for the face layer and 6d cement coated box nails, 2 inches (51 mm) long and spaced 24 inches (610 mm) on center along the studs. The stud cavity contains Icynene insulation nominally 2 inches (51 mm) thick. Axial loads applied to the wall assembly must be limited to the least of the following: ■ 1,805 pounds (8029 N) per stud. ■ Design stress of 0.78 F'c. ■ Design stress of 0.78 F'c at a maximum Idd of 33. 4.5.3 Assembly 3 (Floor/Ceiling): Minimum nominally 2- by-10 [11/2 by 91/4 inches (38 mm by 235 mm)] Douglas fir, No. 2 grade wood joists spaced 24 inches (610 mm) on center, with minimum 1-by-3 [3/4 by 2'/2 inches (19.1 by 64 mm)] spruce bridging at mid -span. Floor decking must be minimum 1/2-inch4hick (12.7 mm) exterior grade plywood installed perpendicular to joists and fastened with 2-inch- long (51 mm) ring shank nails 6 inches,(152 mm) on center at the joints and 12 inches (305 mm) on center at the intermediate joists. Plywood joints must occur over joists. Icynene insulation must be applied to;the underside of the plywood deck between the joists to a depth of 5 inches (127 mm). Two layers of minimum 5/8-inch-thick (15.9 mm), Type X gypsum wallboard must be attached perpendicular to the joists on the ceiling side of the assembly. The first layer must be attached with 11/4-inch-long (32 mm), Type W drywall screws, spaced 24 inches (610 mm) on center. The second layer must be applied perpendicular to the joists, offset 24 inches (610 mm) from the base layer. The second layer must be attached with 2-inch-long (51 mm), Type S drywall screws spaced 12 inches (305 mm) on center. Additional fasteners must be installed along the butt joints of the second layer, securing the two layers together. These fasteners must be 11/2-inch-long (38 mm), Type G drywall screws placed 2 inches (51 mm) back from each end of the butt joint and spaced. 12 inches (305 mm) on center. The wallboard joints on the exposed side must be treated with paper tape embedded in joint compound and topped with an added coat of compound, and the fastener heads must be coated with joint compound in accordance with ASTM C 840 or GA-216. 4.5.4 Assembly 4 (Non-loadbearing Steel Stud Wall): Nominally 6-inch-deep (152.4 mm), No. 18 gage, galvanized steel studs spaced 16 inches (406.4 mm) on center, are friction -fit into No. 18 gage galvanized steel floor and ceiling track with a layer of 5/8-inch-thick (15.9 mm),Type X gypsum board applied to the interior side with the long edge parallel to steel studs and secured using No. 6, 11/4-inch-long (31.7 mm), self- drilling drywall screws spaced 8 inches (203 mm) on center around the perimeter and 12 inches (305 mm) on center in the field. The gypsum board joints must be treated with vinyl or casein, dry or premixed joint compound applied in two coats to cover all exposed screw heads and gypsum board butt joints, and a minimum 2-inch-wide (51 mm) paper, plastic, or fiberglass tape embedded in the first layer of compound over butt joints of the gypsum board. The stud cavity is filled with Icynene insulation up to 6 inches (152 mm) thick. DensGlas? Gold Exterior Sheathing, 112 inch (12.7 mm) thick, is installed parallel to steel studs with vertical joints offset a minimum of 16 inches 406 mm) from the vertical joints of the gypsum board and the horizontal joints offset a minimum of 24 inches (610 mm) from the horizontal joints of the gypsum board. The sheathing is attached using No. 6, 11/4-inch-long (31.7 mm), self -drilling drywall screws spaced 8 inches (203 mm) on center around the perimeter and in the field. Hohmann & Barnard DW-10 brick ties, 6 inches (152 mm) long by 11/2-inches (38 mm) wide, are spaced 16 inches (406.4 mm) on center vertically on each steel stud, and secured, using two 15/8- inch-long (41.3 mm) self -drilling screws, through 4-inch (102 mm) red.clay brick [31/2 inches (88.9 mm) by 2114 inches (57.1 mm) by 73/4 inches (197 mm)] laid in a running bond pattern with Type S mortar, leaving a nominally 1-inch (25.4 mm) air gap between the brick and the exterior sheathing. Optional: It is permitted to add code -complying, expanded polystyrene (EPS), extruded polystyrene (XPS), foil -faced, rigid polyurethane board stock or polyurethane spray foam on the exterior of the wall (between the DensGlas Gold sheathed wall and the brick), while maintaining the 1-inch (25.4 mm) air space. The length of the brick ties must be increased to account for the thickness of the insulation. 4.6 Exterior Walls in Type I, II, III and IV Construction: 4.6.1 General: When used on exterior walls of Types I, II, III or IV construction, the assembly must comply with IBC Section 2603.5 and this section, and the LD-C-50 insulation must be installed at a maximum thickness of 6 . . '!11 ESR-1826 I Most lldei oted and Trusted 4of5 inches (152 mm). The potential heat of Icynene LD-C-50 insulation is 494 Btu/ft2 per inch of thickness, when testing is in accordance with NFPA 259. 4.6.2 Exterior Face: Nominally 6-inch-deep (152 mm), No. 18 gage, galvanized steel studs spaced 16 I inches (406 mm) on center, are fastened to No. 18 gage, galvanized steel floor and ceiling track using I No. 8, /e-inch-long (22.2 mml, self -tapping pan head framing screws. GP DensGlass Gold Exterior Sheathing, '/2inch (12.7 mm) thick, is installed over the exterior side I of steel studs with the long end perpendicular to the steel studs, using No. 6, Type S, 11/4-inch (31.7 mm), self tapping bugle head screws spaced 8 inches (203.2 mm) on center around the perimeter and in the field. The stud cavity is filled with Icynene insulation to a nominal thickness of 6 inches (152 mm). 4.6.3 Interior Face: Type X gypsum board, 5/e inches (15.9 mm) thick, is installed with the long dimension perpendicular to steel studs with No. 6, Type S, 11/4 inch - long (31.7 mm), self -tapping, bugle head screws spaced 8 inches (203 mm) on center around the perimeter and in the field. The gypsum board joints must be treated with vinyl or casein, dry or premixed joint compound applied in two coats to cover all exposed screw heads and gypsum board butt joints, and a minimum 2-inch-wide (51 mm) paper, plastic, or fiberglass tape embedded in the first layer of compound over buttjoints of the gypsum board 4.6.4 Exterior Wall Covering: Details of the exterior wall covering must be provided to the code official by the report holder, designer or specifier, with an engineering analysis demonstrating that (1) the exterior wall covering conforms to ASTM E 136 and (2) the addition of the wall covering to the assembly described in this section does not negatively affect conformance of the assembly with the requirements of IBC Section 2603.5. 5.0 CONDITIONS OF USE The Icynene LD-C-50 spray -applied polyurethane insulation described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 This evaluation report and the ;manufacturer's published installation instructions, when required by the code official, must be submitted at the time of permit application. 5.2 The insulation must be installed in accordance with the manufacturer's published installation instructions, this evaluation report and the applicable code. If there is a conflict between the installation instructions and this report, this report governs. i 5.3 The insulation must be separated from the interior of the building by an approved 15-minute thermal barrier, except when installation is as described in Section 4.3.2 or in attics and scrawl spaces as described in Section 4.4.2 and 4.4.3. 5.4 The insulation must not exceed the thickness and density noted in Sections 3.2, 4.3, 4.4, 4.5 and 4.6. 5.5 The insulation must be protected from the weather during and after application. 5.6 The insulation must be applied by installers certified by Icynene, Inc. 5.7 Use of the insulation in areas where the probability of termite infestation is "very heavy" must be in accordance with IRC Section R318.4 or IBC Section 2603.8, as applicable. 5.8 Jobsite certification and labeling of the insulation must comply with IRC Sections N1101.4 and N1101.4.1 and IECC Sections 303.1.1 and 303.1.2, as applicable. 5.9 A vapor retarder must be installed in accordance with the applicable code. 5.10lcynene LD-C-50 is manufactured in Mississauga, Ontario, Canada, under a quality control program with inspections by Intertek Testing Services (AA-691). 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Spray -applied Foam Plastic Insulation (AC377), dated November 2009, including reports of tests in accordance with Appendix X (Section 4.4.2.1 and Appendix C (Section 4.4.2.2). 6.2 Test report on air leakage rate in accordance with ASTM E 283. 6.3 Reports of room corner fire testing in accordance with NFPA 286. 6.4 Test reports in accordance with ASTM E 119. 6.5 Test report in accordance with NFPA 285, and related engineering analysis. 6.6 Reports of tests in accordance with NFPA 259. 7.0 IDENTIFICATION All packages and containers of Icynene LD-C-50 must be labeled with the Icynene, Inc., name and address; the product name; the flame spread index and the smoke - developed index; the shelf life expiration date; the label of the inspection agency (Intertek Testing Services); and the evaluation report number (ESR-1826). J Intumescent coatings are identified with the manufacturer's name and address, the product trade name and use instructions. 8.0 OTHER CODES 8.1 Scope: The products recognized in this report have also been evaluated for compliance with the following codes: ■ 2006 Intemational Building Code® (2006 IBC) ■ 2006 International Residential Code® (2006 IRC) ■ 2006 International Energy Conservation Code® (2006 IECC) 8.2 Uses: See Section 2.0. 8.3 Description: See Section 3.0. 8.4 Installation: 8.4.1 General: See Section 4.1. 8.4.2 Application: See Section 4.2. 8.4.3 Thermal Barrier: See Section 4.3. 8.4.4 Attics and Crawl Spaces: See Section 4.4. 8.4.5 One -hour Fire -resistance -rated Assemblies: See Section 4.5. 8.4.6 Use in Noncombustible Construction: See Section 4.6. I I ESR-1826 I Most Widely Accepted and Trusted Page 5 of 5 8.5 Conditions of Use: 1 8.6 Evidence Submitted: The Icynene LD-C-50 described in this report complies See Section 6.0. with, or is a suitable alternative to what is specified in, 8.7 Identification: those codes listed in Section 8.1 of this report, subject to Conditions of Use 5.1 through 5.6 and 5.8 through 5.10. See Section 7.0. TABLE 1—THERMAL RESISTANCE (R VALUES) THICKNESS (inches) R-VALUE (°F•fe-h/Btu) 1 3.7 2 I 7 3 I 11 3.5 13 4 14 5 18 5.5 20 6 22 7 I 25 7.5 27 8 29 9 I 32 9.5 34 10 36 11.5 41 14 50 For SI: 1 inch = 25.4 mm, 1 °F•ff-h/Btu = 0.176 110°K•m2NV. 'R-values are calculated based on tested Kvalues at 1- and 3.5-inch thicknesses. I I i ICYNENE LD-C-50® - USA PRODUCT SPECIFICATION 1. PRODUCT NAME Y N E N E FD� - f- - 5" ICYNENE LD-C-50® Is a trademark for light density, open celled, flexible,100% water -blown polyurethane foam insulation manufactured by Icynene Inc. ICYNENE LD-C-5011 spray formula Is a nominal 0.5 Ibs/fta density, free rise material. 2. MANUFACTURER ICYNENE LD-C-509 Is made on -site from liquid components manufactured by Icynene Inc. Installation and on -site manufacturing is supplied by Independent Icynene Licensed Dealers. 3. PRODUCT DESCRIPTION ICYNENE LD-C-5001 the "classic" light density formulation of Icynene has been Installed in buildings since 1986. Icynene is the pioneer of high yield, 100% water -blown polyurethane foam technology for air -sealing and insulating buildings. ICYNENE LD-C-5011 Insulates and air -seals In one step for maximum energy conservation while minimizing the environmental Impact during manufacturing and construction. Significantly reducing air leakage means ICYNENE LD-C-5011 contributes to a healthier, quieter and more comfortable Indoor environment, while reducing energy consumption and related greenhouse gas emissions by as much as 50%. ICYNENE LD-C-50® is an effective vapor permeable air barrier material that can move with the building to maintain the air barrier characteristic against energy -robbing air leakage for the life of the building. Convective air movement Inside wall cavities is virtually eliminated, providing more uniform temperatures throughout the building. The result Is superior quality construction, with higher comfort levels and lower heating and/or cooling costs. Energy savings will vary depending on building design, location, etc. ICYNENE LD-C-500 Is applied by spraying liquid components onto an open wall, crawlspace, telling surface or cathedral ceiling. There It expands approximately 100:1 In seconds to provide a flexible foam blanket of millions of tiny air cells, filling building cavities, cracks and crevices in the process. It adheres to most construction materials, sealing out air Infiltration. Excess material Is easily trimmed off, leaving a surface ready for drywall or other code - compliant finish. 4. TECHNICAL DATA (Based on Core Samples) Thermal Performance Thermal resistance (ASTM C518) I - R/in = R3.7 hr. ft2 OF/BTU Average Insulation contribution In a furl stud wall: 2"x4"= 13 2" x 6" = IR20 ICYNENE LDIC-5011 provides more effective performance than the equivalent R-value of air permeable insulation materials. ICYNENE LD-C- 50® Is not subject to loss of R-value due to aging, windy! conditions, settling, convection or air Inflltration; nor will It be prone to traditional moisture Intrusion via air leakage. A FACT SHEET with R-value data Is available upon request. Air Permcance/Air Barrier /Air -Seal i ICYNENELD-C-50® fills any shaped cavity, and adheres most construction materials, creating assemblies with very low air permeance. Additional Interior or exterior air Infiltration protection Is subject to applicable codes. Air perm) abfllty of core foam: ASTM E283 data - 0.0019 L/s•m2 @ 75 Pa for 3.5" Air permeability of a 2" x 6" wood framed wall assembl Iy: ASTM i E 2178 data i - 0.01 L/s•m2 @ 75 Pa for 5.5" All buildings Insulated and air -sealed with ICYNENE LD-C-500 must be designed to include adequate mechanical ventilation/ outdoor air supply. See ASHRAE Standard 62 — Ventilation for Acceptable Indoor Air Quality. Water Vapor Permeance i ICYNENE LD-C-50® is water vapor permeable and, allows molsture to diffuse through the Insulation and dissipate from the building envelope. Water vapor transmission properties: (ASTM E96 Desiccant Method) - . II perms @ 5.5" In those situations that warrant a vapor retarder, asupplemental layer of polyethylene may be used. Alternately, low vapor permeance paint elther directly on the foam or as a primer for the Interior drywall may be used. Water Absorption Properties Water can be forced Into the foam under pressure because it Is open celled. Water will draln by gravity, given favorable drying potential, and upon drying all chemical and physical properties are fully restored. Acoustical Properties Performance In a 2" x 4" wood stud wall: STC Sound Transmission Class - 37 Hz. Freq. 125 250 500 1000 2000 4000 ASTM E90 19 30 31 42 38 46 NRC Noise Reduction Coefficient - 70 Hz. Freq, 125 250 500 1000 2000 4000 ASTM C423 .11 .43 .89 .72 .71 .67 Burn Characteristics ICYNENE LD-C-50® Is a combustible product and is therefore, consumed by flame, but will not sustain flame upon removal of the flame source. It leaves a charred foam residue. It will not melt or drip. ICYNENE LD-C-500 Is subject to all applicable National/State and County building codes regarding fire prevention. Requirements for Thermal Barrier and Ignition Barrier coverings must be met as per the applicable building code having jurisdiction. U.S. Fire Testing Surface Burning Characteristics of (ASTM E841 @ 5" Thickness Flame Spread 525 Smoke Development -e450 *Flame spread rating not Intended to reflect hazards under actual fire conditions. Electrical Wiring ICYNENE LD-C-50® has been evaluated with energized 14/3 and 12/2 residential wiring (max. 1220F). It Is chemically compatible with typical electrical wiring coverings. Note: For any Insulation of knob and tube wiring, please reference local electrical code. Corrosion ICYNENE LD-C-5011 did not cause corrosion when evaluated In contact with steel at 120°F and 85% relative humidity conditions. ICYNENE LD-C-50® - USA Plastic Piping ICYNENE LD-C-50® Is compatible In direct contact with CPVC piping systems, as per Paschal Engineering Study for the Spray Polyurethane Foam Alliance (SPFA). Bacterial or Fungal Growth and Food Value Independent testing conducted by Texas Tech University has confirmed that ICYNENE LD-C- 50® Is not a source of food for mold; and as an air barrier material, It resists the airborne Introduction of moisture, nutrients, and mold spores Into the building envelope. Environmental / Health / Safety ICYNENE LD-C-500 is 100% water -blown and therefore contains no ozone -depleting blowing agents. It Is also PBDE-free. It has been thoroughly evaluated for in -situ emissions by Industry and government experts. VOC emissions are below 1/100th of the safe concentration level (TLV) within hours following the application of ICYNENE LD-C-50®. Proper handling and use is required to avoid exposure to reactive chemicals in their unreacted state. For more Information, contact the Spray Polyurethane Foam Alliance or the American Chemistry Council. Newly Insulated areas have been shown to be safe for occupancy 24 hours after Installation Is complete. ICYNENE LD-C-50® is CHPS E.Q. 2.2/Section 01350 Compliant and listed as such In the Collaborative for High Performance Schools (CHPS) Low Emitting Materials (LEM) Table. Under LEED guidelines, products that are CHPS E.Q. 2.2/Section 01350 Compliant are considered Environmentally Preferable Products. The reaction used to create ICYNENE LD-C-50® generates Carbon Dioxide to expand the foam. Carbon Dioxide has a very low Global Warming Potential (GWP of 1). Not Intended for exterior use. Not to be Installed within 3" of heat emitting devices or where the temperature Is In excess of 200°F, as per ASTM C411 or in accordance with applicable codes. Telephone: 906.363.4040 ' Toll Free: 800.758.7325 Facsimile: 906.363.0102 Website: www.Icynene.com E-mail: inquiry@lcynene.com SL-200-05 — October 2010 5. INSTALLATION ICYNENE LD-C-50® is Installed by a network of Licensed Dealers, trained In the Installation of ICYNENE LD-C-50®. Installation Is generally Independent of environmental conditions. It can be Installed In hot, humid or, freezing conditions. Surface preparation Is generally not necessary. Within seconds, the foaming process Is complete. For Information! on Health and Safety, refer to the Spray Polyurethane Foam Alliance Health and Safety guidance documents at www.spraypolyuIrethane.com 6. AVAILABILITY Check regional Yellow Pageff or contact Icynene,lnc. at ,800-758-7325 or our website at www.icynene.com for a local Icynene Licensed Dealer. 7. WARRANTY WHEN INSTALLED PROPERLY IN ACCORDANCE WITH INSTRUCTIONS, THE COMPANY WARRANTS THAT THE PROPERTIES OF THE PRODUCT MEET PRODUCT SPECIFICATIONS AS OUTLINED IN THIS PRODUCT SPECIFICATION SHEET. SAVE AND EXCEPT ANY EXCLUSIONS REFERENCED IN THE WARRANTY. 8. TECHNICAL I Icynene Licensed Dealers and Icynene Inc. provide support on Both technical and regulatory Issues. Architectural specifications in CSI 3-Part format and design details are available upon request. 9. REGULATORY ICYNENE LD-C-50® has been tested as per the requirements of the International Code Council — Evaluation Service's AC377 Acceptance Criteria (June 2009). i The following evaluation reports apply to this product: ! ICC ESR-1826 Based on the 3rd party test evidence submitted, this product was found to comply with: IRC — 2006 — 2009 IBC — 2006 — 2009 IECC — 2006 — 2009 10.RELATED REFERENCES All physical properties were determined through testing by accredited third -party agencies. Icynene Inc. reserves the right to change specifications In Its effort of continuous Improvement. Please confirm that technical data literature Is current. 11. PACKAGING AND STORAGE Packaging 55 U.S. gallon steel drums Component 'A' 550 lb. per drum Base Seal0 MDI Component 'B' 500 lb. per drum ICYNENE LD-C-50® (Gold Seal®) Resin Storage Component A, Base Seal® MDI and Component B, ICYNENE LD-C-501' Resin Ideally should be stored between 60°F and 90°F. Component A, Base SealO, should be protected from freezing. Component B, ICYNENE LD-C-50® (Gold Seal®) Resin, can be frozen but must be protected from overheating 1201 and prolonged storage above 100°F. Component B, ICYNENE LD-C-50® (Gold SeaI9 Resin, may separate during storage and should be mixed thoroughly prior to use. 12. INSTALLATION SPECIFICATIONS Must be Installed by Icynene Licensed Dealers. Refer to the Icynene Installer's Manual for expanded information.