Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FLOOR PLAN
i 1 7 Project: AVALON BEACH MODEL - C 6408 OCEAN ESTATES COURT HUTCHINSON ISLAND FORT PIERCE, FLORIDA Key Plan: Issues: No.: Date: Description: 1. 2/13/12 FINAL ARCHITECT: Atelier d'Architecture By J. L. Ray, LLC 912 22nd Place Vero Beach, Florida 32960 (772) 770-9622 ph/fax (772) 766-1611 cell Drawing Title: 3RD FLOOR ELECTRICAL PLAN J.L.R. Chd: Project No.: J.L.R. 1119 Sheet No.: Reg. No.: AA26001760 A E 3 ` 10 Lic. No,: AR94653 Date SignFcEB 16 2 IfIt CMFFgh<.© 2WI. AW* Al-hlt--Wn 81 L L Fay, LLC Project: PANEL: "A" VOLTAGE: 120/240V BUSIBREAKER AIC RATIN 22KAMOKA RATING: 225A LOCATION: FOYER MECH CLOSET MOUNTING: SURFACE NEMA-1 MAIN CONNECTION: MLO FED FROM: MDP DEVICE FAMILY: DESCRIPTION "w � H -- � m P CONNECTED KVA No. CONNECTED KVA A B r K w w DESCRIPTION A B No. 1FL RANGE/OVEN 8 50 2 2.5 1 2 1.08 1 20 12 1FL MEDIA RM RECEP 8 2 2.5 3 S 0 7 9 1.6 11 4 6 8 10 12 0.72 0.9 0.72 1.08 1 1 1 1 1 20 20 20 20 20 12 12 121 12 12 1FL BREAKFAST RM RECEP 1FL RANGE HOOD SPACE 12 12 20 20 20 20 1 1 1 1 D.6 1FL FAMILY RM EAST RECEP 1FL FAMILY RM WEST RECEP 0.7 0.18 1FL REFRIGERATOR 1FL MICROWAVE 12 12 1FL FAMILY RM FIRE PLACE 2FL SOUTH MASTER RECEP 1FL SMALL APPLIANCE 12 20 1 1.5 13 14 0.72 1 20 12 2FL NORTH MASTER RECEP 1FL SMALL APPLIANCE 12 20 1 1.5 15 16 0.9 j 1 20 12 2FL SITTING RM RECEP 1FL DISHWASHER 12 20 1 1.2 17 18 0.54 1 20 12 2FL HER CLOSET RECEP 1FL FREEZER 12 20 1 0.9 19 20 1.41 1 20 12 2FL HER BATH 1FL LTS-KITCHEN/HALL 12 20 1 1.8 21 22 1.6 1 20 121 2FL HER JACUZZI TUB 1FL LTS-GREAT RM 12 20 1 0.9 23 24 1 1 20 12 2FL WASHER 1FL LTS-MEDIAISTAIR 12 20 1 1.4 25 26 2.5 2 30 10 2FL DRYER 1FL POWDER/2FL HIS BATH 12 20 1 1.7 27 28 2.5 2 10 2FL MASTER SUITE / SITTING LTS 12120 1 1.73 29 30 1 1 20 12 2FL HER WASHER 2FL SITTING RM/HER CLOS/LAUN LTS 12 20 1 1.7 31 32 2.5 2 30 10 2FL HER DRYER 1FL NORTH EXTERIOR FAN/LTS 12 20 1 1.2 33 34 2.5 2 10 1FL TERRACE APP RECEP 12 20 1 0.18 35 36 0.36 1 20 12 1F1 MEDIA RM TV RECEP 1FL TERRACE REFRIGERATOR 12 20 1 0.7 37 38 0.72 1 20 12 2FL BATH TV I PHONE RECEP 1FL TERRACE GRILL STARTER 12 20 1 0.18 39 40 0 1 20 12 SPACE SPACE 12 20111 0 41 42 0 1120 12 SPACE 13.33 11.16 TOTAL1 41.56 11.37 # TOTAL KVA SERVES CONNECTED LOAD - KVA DF CALCULATED DEMAND - KVA LIGHTING 10.38 1.25 12.98 RECEPTACLES (FIRST 10 KVA) 12.36 1.00 10.00 RECEPTACLES (OVER 10 KVA) 2.36 0.50 1.18 LARGE MOTORS 1.60 1.25 2.00 OTHER MOTORS 5.28 1.00 5,28 EQUIPMENT/HEAT 10.00 1.00 10.00 KITCHEN EQUIPMENT 6.24 0.00 PANEL 1.00 0.00 TOTAL DEMAND KVA: 41.44 TOTAL AMPERAGE: 172.65 NOTES: 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO BIDDING AND INSTALLATION. 2. PROVIDE TYPE WRITTEN DIRECTING ON INSIDE PANEL COVER 3. ALL AC EQUIPMENT TO HAVE HACR TYPE BREAKERS 4. ALL SINGLE POLE 20A BREAKERS TO BE AFCI / GFCI TYPE BREAKERS. PANEL: VOLTAGE: 120/240V 1PH 3W BUS/BREAKER AIC RATING: 22KA/10KA RATING: 100A LOCATION: FOYER MECH CLOSET MOUNTING: FLUSH NEMA-1 MAIN CONNECTION: MLO FED FROM: MDP DEVICE FAMILY: DESCRIPTION m P CONNECTEDBp No.Nm CONNECTED KVA P m § 10 DESCRIPTION A A 3FL KID RM/BED 3 LTS 12 20 1 1.375 1 2 0.72 1 20 12 3FL W EXT RECEP 3FL BED 2/BED 1 LTS 12 20 1 1.5 3 4 0.87 1 20 12 3FL E EXT RECEP/ATTIC LT 3FL BATHS LTS RECEP 12 20 1 1.89 5 6 1.08 1 20 12 3FL STAIRIHALL RECEP SPACE 0 7 8 0.9 1 20 12 3FL KIDS RM RECEP SPACE 0 9 SO 1.44 1 20 12 3FL BED 3 RECEP SPACE 0 11 12 1.44 1 20 12 3171- BED 2 RECEP SPACE 0 13114 1.44 1 20 12 3FL BED 1 RECEP SPACE 0 15116 0 SPACE SPACE 0 17 18 0 SPACE SPACE 0 19 20 0 SPACE SPACE 0 21 22 0 SPACE SPACE 0 23 24 0 I SPACE 3.265 1.5 TAL 4.68 3.21 12.7 TOTAL KVA CONNECTED LOAD - KVA OF CALCULATED DEMAND - KVA LIGHTING 4.34 1.25 5.43 RECEPTACLES (FIRST 10 KVA) 8.28 1.00 8.28 RECEPTACLES (OVER 10 KVA) 0.00 0.50 0.00 LARGE MOTORS 0.94 1.25 1.17 OTHER MOTORS 0.15 1.00 0.15 EQUIPMENT/HEAT 0.00 1.00 0.00 KITCHEN EQUIPMENT 0.00 1.00 0.00 PANEL 1.00 0.00 TOTAL DEMAND KVA: 15.03 TOTAL AMPERAGE: 162.63 NOTES: 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO BIDDING AND INSTALLATION. 2. PROVIDE TYPE WRITTEN DIRECTING ON INSIDE PANEL COVER 3. ALL AC EQUIPMENT TO HAVE HACR TYPE BREAKERS 4. ALL SINGLE POLE 20A BREAKERS TO BE AFCI / GFCI TYPE BREAKERS. PANEL: "MOP" VOLTAGE: BUS/BREAKER AIC RATING: 1201240V 1PH 3W 22KA122KA RATING: 400A LOCATION: MOUNTING: GARAGE SURFACE NEMA-1 FED FROM: ATS MAIN CONNECTION: MCB DEVICE FAMILY: DESCRIPTION q m P No. No coNANECTED6A P m DESCRIPTION ANECTEDBKVA ELEVATOR MOTOR 10 30 2 1.35 1 2 31.32 2 100 3 PANEL-C 10 2 1.35 3 4 31.32 2 3 ELEVATOR LTS 12 20 1 0.15 5 6 0 2 60 6 LANSCAPE/SITE LTS PANEL ELEVATOR SERVICE RECEP 12 20 1 0.18 7 8 0 2 6 PANEL -A 4 0 225 2 20.39 9 110 0 1 20 12 3FL BED 3 RECE 4 0 2 20.39 11 12 0 1 20 12 3FL BED 2 RECE PANEL-13 250 250 2 29.09 13 14 0 1 20 12 3FL BED 1 RECE 250 2 29.09 15 16 0 SPACE SPACE 0 17 18 0 SPACE SPACE 0 19 20 0 SPACE SPACE 0 21 22 0 SPACE SPACE 0 23 24 0 SPACE 50.98 51.01 TAL 31.32 31.32 164.6 TOTALKVA CONNECTED LOAD - KVA DF CALCULATED DEMAND - KVA LIGHTING RECEPTACLES (FIRST 10 KVA) RECEPTACLES (OVER 10 KVA) LARGE MOTORS OTHER MOTORS EQUIPMENT/HEAT KITCHEN EQUIPMENT PANELS A,B,C,SITE-LIGHT TOTAL DEMAND KVA: TOTAL AMPERAGE: SEE SERVICE ENTRANCE/MDP LOAD CALCULATION NOTES: 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO BIDDING AND INSTALLATION. 2. PROVIDE TYPE WRITTEN DIRECTING ON INSIDE PANEL COVER 3. ALL AC EQUIPMENT TO HAVE HACR TYPE BREAKERS 4. ALL SINGLE POLE 20A BREAKERS TO BE AFCI / GFCI TYPE BREAKERS. PANEL: "Brr VOLTAGE: 1201240V 1PH 3W BUSIBREAKER AIC RATING: 22KA/22KA RATING: 250A LOCATION: GARAGE MOUNTING: SURFACE NEMA-1 MAIN CONNECTION: MLO FED FROM: MDP DEVICE FAMILY: DESCRIPTION 3 m p COANECTEDBVA No. COANECTEDB A p m N DESCRIPTION Na. CU-1 PER MFG 2 2.932 1 2 1.5 2 PER MFG AHU-4 PER MFG 2 2.932 3 4 1.5 2 PER MFG CU-2 PER MFG 2 2.932 5 6 1.5 2 PER MFG AHU-5 PER MFG 2 2.932 7 8 1.5 2 PER MFG CU-3 PER PER MFG MFG 2 2 3.427 9 3.427 11 10 12 1.5 1.5 2 2 PER PER MFG MFG AHU-6 CU-4 PER MFG 2 2.047 13 14 0.3 2 PER MFG AHU-7 PER MFG 2 2.047 15 16 0.3 2 PER MFG AHU-1 PER MFG 2 0.3 17 18 0.3 2 PER MFG AHU-8 PER MFG 2 0.3 19 20 0.3 2 IPER MFG AHU-2 PER MFG 2 0.15 21 22 1.2 1 20 12 CENTRAL VAC-1 PER MFG 2 0.15 23124 0 SPACE AHU-3 PER MFG 2 0.15 25I 26 0.35 1 20 12 ENTRY WALL LTS PER MFG 2 0.15 27 28 0.405 1 20 12 GUEST BATH GARAGE EXT LTS GUEST E BED RECEP 12 12 20 20 1 1 1.2 29 1.08 31 30 32 1.35 1.08 1 1 20 20 12 12 GUEST LTS GUEST SITTING RECEP GARAGE RECEP 12 20 1 0.72 33 34 1.26 1 20 12 GUEST W BED RECEP WHA 10 30 2 2.25 35 36 1.2 1 20 12 GARAGE DOOR 10 2 2.25 37 38 1.2 1 20 12 GARAGE DOOR WH-2 10 30 2 2.25 39 40 0.18 1 20 12 WHA RECIRC PUMP 10 2 2.25 41 42 0.18 1 20 12 WH-2 RECIRC PUMP 18.36 17.52 1 TOTAL 10.64 7.965 54.5 TOTAL KVA SERVES CONNECTED LOAD - KVA DF CALCULATED DEMAND - KVA LIGHTING 3.13 1.25 3.91 RECEPTACLES (FIRST 10 KVA) 14.68 1.00 4.68 RECEPTACLES (OVER 10 KVA) 0.00 0.50 0.00 LARGE MOTORS 6.85 1.25 8.57 OTHER MOTORS 30.82 1.00 30.82 EQUIPMENT/HEAT 9.00 1.00 9.00 KITCHEN EQUIPMENT 0.00 1.00 0.00 PANEL 1.00 0.00 TOTAL DEMAND KVA: 56.98 TOTAL AMPERAGE: 237.40 NOTES: 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO BIDDING AND INSTALLATION. 2. PROVIDE TYPE WRITTEN DIRECTING ON INSIDE PANEL COVER 3. ALL AC EQUIPMENT TO HAVE HACR TYPE BREAKERS 4. ALL SINGLE POLE 20A BREAKERS TO BE AFCI / GFCI TYPE BREAKERS. RESIDENTIAL LOAD CALCULATIONS FOR MAIN PANEL "A" APPROXIMATE SQUARE FOOTAGE = 3,738 DESCRIPTION TOTAL LOAD GENERAL POWER & LIGHTING @ 6,854 So. FT, x 3 VOLT AMPERES 20.6 KVA (4) SMALL APPLIANCE CIRCUITS 0 1,500 VOLT-AMPERES EACH . 6.0 KVA (7) RANGE HOOD 0.6 KVA l61 BATH EXHUAST 0.6 KVA (1) DISHWASHER 1.2 KVA (4) REFRIGERATOR 2.8 KVA (11 OVEN 5.0 KVA (1) FRONT GATE 2.4 KVA (1) TRASH COMPACTOR 1.6 KVA (1) MICROWAVE 1.6 KVA (2) RECIRC PUMP .4 KVA (2) DISPOSAL 1.0 KVA (2) DRYER 6.0 KVA (1) JACUZZI TUB 1.6 KVA . LAUNDRY SMALL APPLIANCE INCLUDED TOTAL 37.80 KVA FIRST 10 KVA @ 100% 10.0 KVA REMAINDER @ 40% 143.4 KVA x .4) 17.4 KVA AIR CONDITIONING @ 100% 34.1 KVA HEAT STRIPS (0 KVA X 65%) N/A KVA ELEVATOR 0100% 1.4 KVA POOL/SPA EQUIP.0100% 7.5 KVA TOTAL PANEL 70.4 KVA PANEL SIZE ( 10.4KVA / 240V) = 294 AMPS ELECTRICAL SPECIFICATIONS 1. DO NOT SCALE THE ELECTRICAL DRAWING, REFER TO THE ARCHITECTURAL PLAN AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT AND CONFIRM WITH OWNERS REPRESENTATIVES. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2008 EDITION OF THE NATIONAL ELECTRICAL CODE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES. 3. UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER, WITH "THHN" INSULATION FOR SIZE #10 AND SMALLER. CONDUCTORS LARGER THAN #10 SHALL HAVE "THWN" INSULATION. ALL CONDUCTORS #10 AND SMALLER MAY BE SOLID. ALL CONDUCTORS #8 AND LARGER SHALL BE STRANDED. 4. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. 5. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK MAKE, QUICK BREAK, WITH ENCLOSURES AS REQUIRED BY EXPOSURE. 6. THESE PLANS DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION, THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND MEET ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 7. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED IN ARTICLE 250, NATIONAL ELECTRICAL CODE. 8, ALL MATERIALS SHALL BE NEW AND SHALL BEAR U.L. LABELS WHERE APPLICABLE. 9. ALL WORK SHALL BE PERFORMED BY A LICENCED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANSHIP MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY ENGINEER/ARCHITECT MUST BE A CONDITION OF THE SUBCONTRACTOR, 10. THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF POWER, LIGHT COMPANY AND TELEPHONE COMPANY. 11, CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZE. THE CONTRACTOR SHALL PROVIDE CIRCUITS TO SUIT JOB CONDITIONS. 12. SEE NOTES ON PLANS FOR OTHER REQUIREMENTS. 13. FURNISH AND INSTALL LIGHTING FIXTURES AND LAMPS AS CALLED FOR ON PLANS, OR AS SELECTED BY OWNER, 14. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROCESS OF CONSTRUCTION, 15. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE BY CONTRACTOR AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY PHASE OF THE INSTALLATION WHICH MAY BE DAMAGED. 16. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC [[<I .•,a-;. •1 31 is ° ),, "` a F :'"(1i �aa4 xq LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK. Leed e 17. CHECK ALL EQUIPMENT FOR PROPER VOLTAGE, PHASE, AND CURRENT BEFORE CONNECTION TO CIRCUITS. THESE PLANS AND A61- PRr; +GSEO Ylgn}. ARE SUBJECT TO ANY P: JS.F=I„TI4) td"z1 REQUIRED By rIaLJD C R5 ni.,T MAY BE NECES:6A1;tY IN QRGF:R TO COMPLY WITH ALLAPPl4PAE�IgF CODES. EXTERIOR INTERIOR 18. ELECTRICAL CONTRACTOR SHALL CHECK AND VERIFY EQUIPMENT FURNISHED AGAINST THOSE SPECIFIED OR INTENDED AND REVISE BRANCH CIRCUITS AS MAY BE REQUIRED WITH PRIOR APPROVAL OF ENGINEER/ARCHITECT. AIR CONDITIONING EQUIPMENT AND CONTROLS SPECIFICATION 1. ELECTRICAL CONTRACTOR SHALL INSTALL ALL CONTROL RACEWAY (CONDUIT), WIRE INSTALLATION, CONNECTIONS ETC. IN ACCORDANCE WITH WIRING DIAGRAMS ON AIR EQUIPMENT. 2. A/C / ELECTRICAL PLANS OR DIAGRAMS FURNISHED BY MANUFACTURER OF THE EQUIPMENT. 3, ALL POWER WIRING FOR THE AIR CONDITIONING EQUIPMENT SHALL BE FURNISHED, INSTALLED AND CONNECTED UNDER THIS SECTION OF THE SPECIFICATION. 4. MECHANICAL CONTRACTOR SHALL PROVIDE MOTOR STARTERS FOR ALL AIR CONDITIONING EQUIPMENT. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONECTIONS TO AIR CONDITIONING EQUIPMENT PER MANUFACTURERS SPECIFICATIONS. S. AIR CONDITIONING EQUIPMENT INCLUDES CONDENSOR, COMPRESSOR AND FAN, FAN COIL UNITS, ELECTRICAL STRIP HEATER, THERMOSTAT, ETC. �E HACR TYPE BREAKER FOR AHU& & [Us ATS 3 # 600MCM 1 # 2/0 GND 3 # 4/0 3 POLE, 400A THWN CU 1 # 2 GND 4" CI TH C N CU O400A 1 PH 3W, 120/240V GENERATOR W/ 11 M D P RESIDENTIAL GRADE EXHAUST HOOD, WEATHER PROOF ENCLOSURE & 3 # 900MCM LOAD SHEDDING ATS 400A THWN ALUMINUM 4" C OR EMERGENCY 3 # 600MCM GENERATOR THWN C BY OTHERS 4"C GREADE 3 # 600MCM 1 It 2/0 GND THWN CU TO PAD MOUNT 5J 4" C 1PH 120/240 3W UTILITY TRANSFORMER 1 # 2/0 CU BOND TO C.W.P. 1 # 2 1 # 2 BOND TO FOOTER STEEL 5/8"OxlOFT GNO ROD 3#1/0 162 1#6GND CU THWN CU 2" C 3 # 250 1#2GND THWN CU 2" C 91 10 V 10 Mo., CONNECT TO BUILDING STEEL AND COLD WATER 1 # 2 1 # 8 PIPE WITHIN 5 FEET CU CU 3 # 3 1#8GND THWN CU 2" C BOND TO BOND TO C.W.P. 1# 2 1# 2 C.W.P. 1# 8 \� --6�-�1 # 8 BOND TO BOND TO FOOTER STEEL - FOOTER STEEL RISER DIAGRAM GND ROD GND ROD GND ROD GND ROD R m e m009601 AVALON BEACH MODEL - C 6408 OCEAN ESTATES COURT HUTCHINSON ISLAND FORT PIERCE, FLORIDA Key Plan: Issues: No.: Date: Description: 1. 2/13/12 FINAL ARCHITECT: Atelier dlArchitecture By J. L. Ray, LLC 912 22nd Place Vero Beach, Florida 32960 (772) 770-9622 ph/fax (772) 766-1611 cell SEAL: Drawing Title: ELECTRICAL NOTES, PNL SCHEDULES & RISER Reference North J.L.R. Chd: Project No.: J.L.R. 1119 Sheet No.: Reg, No.: AA26001760 Lic. No.: AR94653 E 4 < 10 Date SigneFU �a Copyright © 2011. Atelier d'Archilecture By J. L Ray, LLC Project: POOL EQUIP. BY OTHERS --1 Fill 1/2'H&CW DROP 1/2'HW TO DW 3'S STACK UP POOL HEREQU3'S DN IN WALL 1-1UND DN BY OTHERS Hg 1-1/20V UP 2 POTANKSE(BY LP SUPPLIER) 1-1/2'V RISE REGULATOR�'p- SECONDARY LP (11.0h (11,0 In,w,c,) - 1-1/2' RISE LP 3/4'LP ON TO BELOW FL. -� �,}• _� 4• RUN BELOW FL IN SEALED 0 �0 f g LAV POWDER 1-1/2'V RISE _ _ _ WDERROOM CONDUIT VENTED THRU -4� - - - o C THE OUTSIDE WALL. LP V 00 I<S DW 1/2• D 2'W DN 2'V UP 1 II 1 3/4'LP UP FROM BELOW FL. O Oo OO 9 MEDIA ROOM REF I OYEY RRFOYER KITCHEN 2' ENTRY I 3/4' 4' I LP 1/2' LP— 1-1/2' r 3/4' \ ❑. LP O 4' F4' rl-1/2'HD 1/P, CW UP 3'S DNCODE IN WALL 2'V UP�— _ — — -TIT � � — — DWH-2 3/4'� 1-1/2'V UP � I 2 2'W UP TO WOB 3 2'W UP TO LS 1/2 CW UP — 2' 2' 2'W UP TO FD O� 2'W UP TO WOH n 00 � 2'4l UP TO FD COVERED I v--► N*\�TO LAVW UP TERRACE GREAT COURTYARD J 2'W UP TO CS ROOM I J LP HB 3' 3"I 1/2H&CW DROP 1/2 • 1/2L �J 3/4 _ 4 _ J L - SINK • 3'S DN • LP 2'V UP L ® a 1 IN WALL 3�O LE�3'S STACK UP 1/2• -2•V UP �3'S DN IN WALL CTG • CTG \------F 4' PLUMBING SPECIFICATIONS 1. GERM CONDITIONS: MATERIALS: NEW, UNUSED, BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS AS INDICATED ON THE DRAWINGS, BASIS OF QUALITY SHALL BE LATEST STANDARDS OF ASTM, ASA, FEDERAL SPECIFICATIONS OR OTHER ACCEPTABLE STANDARDS. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF WORK. CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES THIS CONTRACTOR SHALL PAY ALL FEES, GIVE ALL NOTICES, FILE ALL NECESSARY DRAWINGS AND OBTAIN ALL PERMITS AND CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH ALL WORK UNDER THIS CONTRACT. HE SHALL COMPLY NTH ALL NATIONAL AND LOCAL LAWS, ORDINANCES, RULES AND REGULATIONS AND THE STATE ENERGY CODE 2. CUTTING AND PATCHNGr. THE CONTRACTOR SHALL DO ALL PATCHING AND CUTTING REQUIRED TO SATISFACTORILY PERFORM HIS WORK. NO STRUCTURAL MEMBER SHALL BE CUT WITHOUT THE PRIOR APPROVAL OF THE ARCHITECT. 4. 1R)RB INCLUDED: THESE SPECIFICATIONS AND THE ACCOMPANYING DRAWINGS ARE INTENDED TO SECURE THE PROVISION OF ALL MATERIALS AND LABOR NECESSARY FOR ALL PLUMBING WORK AS CALLED FOR HEREIN AND AS INDICATED ON THE DRAWINGS. SYSTEMS SHALL BE COMPLETE WITH ALL NECESSARY APPURTENANCES AND MINOR AUXILIARIES REQUIRED TO MAKE EACH SYSTEM COMPLETE IN EVERY RESPECT. ALL WORK DESCRIBED IN THE SPECIFICATIONS AND NOT SHOWN ON THE DRAWINGS OR VICE VERSA SHALL BE FURNISHED IN COMPLETE WORKING ORDER. FOLLOWING IS A GENERAL DESCRIPTION OF WORK TO BE DONE: NEW DOMESTIC HOT & COLD WATER DISTRIBUTION SYSTEM CONNECTED TO PUBLIC WATER MAIN. NEW SANITARY AND WASTE PIPING CONNECTED TO PUBLIC STREET MAINS. NEW VENT PIPING EXTENDED THROUGH THE ROOF. TESTS, ADJUSTMENTS, SHOP AND AS -BUILT DRAWINGS, PERMITS, CERTIFICATES AND APPROVALS. PIPE INSULATION ON ALL WATER PIPING. HANGERS AND SUPPORTS. ALL REQUIRED VALVES, CONTROLS AND VALVE ACCESS DOORS 6. PIPE INSTALLATION: THE WORD 'PIPING' IN THIS SPECIFICATION MEANS PIPE, FITTINGS, NIPPLES AND VALVES AND SHALL BE CONSIDERED AS SUCH IN THE INSTALLATION. ALL WATER PIPING SHALL BE RUN LEVEL AND GENERALLY FREE OF TRAPS AND UNNECESSARY BENDS, ARRANGED TO CONFORM TO THE BUILDING REQUIREMENTS AND TO SUIT THE NECESSITIES OF CLEARANCES FOR OTHER MECHANICAL NORK. ALL HOT AND COLD WATER PIPING SHALL BE SEPARATED BY AT LEAST 6' (CENTER TO CENTER) AND INSTALLED SO THAT THE PIPES DO NOT COME IN CONTACT. WHERE THE PIPING IS PARALLEL, AMPLE SPACE SHALL BE PROVIDED BETWEEN PIPING FOR THE PROPER THICKNESS OF COVERING AND PROPER OPERATION OF VALVES. ALL PIPING SHALL HAVE REDUCING FITTINGS WHERE ANY CHANGE IN THE PIPE SIZES OCCUR. NO BUSHINGS WILL BE ALLOWED. NO VALVE STEM SHALL BE INSTALLED BELOW THE CENTERUNE OF THE PIPING IT SERVES. CONNECTIONS BETWEEN WATER PIPE, FITTINGS AND EQUIPMENT OF FERROUS AND NON-FERROUS METALS SHALL BE MADE WITH DI -ELECTRIC INSULATING COUPLINGS. 7. IIl M ATION, PROVIDE I' ARMAFLEX INSULATION ON ALL HOT AND COLD WATER PIPING, VALVES, AND EQUIPMENT. 8. HANGBR.9 AND SUPPORTS. ALL PIPING SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE BY MEANS OF APPROVED HANGERS AND SUPPORTS. HANGERS IN CONTACT WITH COPPER SHALL BE COPPER -PLATED. PIPING SHALL NOT BE HUNG FROM THE PIPING, DUCTWORK OR CONDUITS OF OTHER TRADES. 9. PH'FS, Ifl7'PINGB AND JOHM- ALL WATER PIPING SHALL BE HARD DRAWN, COPPER TUBING TYPE 'L'. FITTINGS SHALL BE WROUGHT COPPER. COPPER TUBING AND PIPING SHALL BE MADE UP WITH SOCKET FITTINGS, PATH 95-5 SOLDER JOINTS OR NTH SILVER SOLDERED BRAZED JOINTS. (ASTM B 88) SANITARY, WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC/DWK OUTDOOR LIQUEFIED PETROLEUM GAS (LPG) PIPING FROM SECONDARY REQULATOR TO BUILDING WALL TO BE POLYETHYLENE PLASTIC PIPING, SDR 11.0. INDOOR LIQUEFIED PETROLEUM GAS (LPG) PIPING FROM OUTSIDE WALL TO APPLAINCES TO BE SCHEDULE 40 BLACK STEEL PIPE ASTM A 53 WITH MALLEABLE IRON FITTINGS. 10. MYEL DOMESTIC HOT AND COLD WATER SHUT-OFF VALVES SHALL BE 'MILWAUKEE' JBA-155 (OR APPROVED EQUAL); SWEAT ENDS, FORGED BRASS, FULL PORT, BALL -TYPE VALVE (OR APPROVED EQUAL). 11. EQUD?Hm CONNECTIONS: CONTRACTOR SHALL FURNISH ALL REQUIRED VALVES, FITTINGS, VACUUM BREAKERS, TRAPS, ETC., NECESSARY FOR THE COMPLETE HOOKUP TO PROVIDE PROPER OPERATION OF EACH PIECE OF EQUIPMENT. IN CONNECTING TO EQUIPMENT, MANUFACTURER'S RECOMMENDATIONS AS TO SIZE AND ARRANGEMENT OF CONNECTIONS SHALL BE FOLLOWED, BUT WITH SIZES SHOWN ON PLAN BEING FOLLOWED. 12. DIETIECTION9 AND TESTS: THE OPERATION OF THE EQUIPMENT AND PIPING INSTALLATION DOES NOT CONSTITUTE AN ACCEPTANCE OF THE WORK BY THE OWNER. THE FINAL ACCEPTANCE IS TO BE MADE AFTER THE CONTRACTOR HAS ADJUSTED HIS SYSTEM AND DEMONSTRATED THAT IT FULFILLS THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS AND HAS FURNISHED REQUIRED CERTIFICATES. TEST ALL SYSTEMS IN FULL ACCORDANCE WITH LOCAL STATE AND UTILITY COMPANY REQUIREMENTS. T-4' PLUMBING SYMBOLS SANITARY do WASTE PIPING BELOW FLOOR (S) (W) SANITARY do WASTE PIPING ABOVE FLOOR (S) (W) - - - - VENT PIPING - COLD WATER PIPING (CW) - - HOT WATER PIPING (HW) - - - HOT WATER RETURN PIPING (HWR) LP LIQUEFIED PETROLEUM GAS PIPING (PROPANE) r BALL VALVE f)4 GATE VALVE N CHECK VALVE 0 CLEAN OUT DECK PLATE II- HORIZONTAL CLEANOUT b GAS COCK v- iL—:)o P TRAP 7 PIPE DOWN, DROP & RISE __o PIPE UP 0- TEE PLAN UP -g- TEE PLAN DOWN CTG CLEANOUT TO GRADE VTR VENT THRU ROOF HB HOSE BIBB W/ VACUUM BREAKER CTG VENT THRU ROOF FD FLOOR DRAIN ( BRONZE FINISH) HD CONDENSATE OPUN HUB DRAIN NOTE THAT NOT ALL SYMBOLS APPLY TO THE PROJECT ruervk, r,.`e iri 1r4.w,1 av4{il�fa GT' d b' AiP f, qT� GENERAC LP GENERATOR AND CONCRETE GENERATOR PAD BY OTHERS COVERED ENTRY THESE PLANS AND ALL PROPOSED WM, ARE SUBJECT TO ANY CoPPFCTIOid REQUMAY IRED BY FfELO fNSPEO'ORS T,4A7 COMPLY WITH ALL RAPIPLICA Lc CQQjS. \ SEE SITE PLAN FOR LP TANK LOCATION CTG 4' 1-1/2, CW SE�tVICE UP FROM BEL❑W SLAB 2 CAR GARAGE L — r4' KEY NOTES O3'S UP TO WC/BD O2'W UP TO LAV O2'W UP TO SH O2'W UP TO TUB O2'W DN 1-1/2'V RISE 1/2'H&CW DROP O1-1/2'W DN 1-1/2'V RISE 1/2'H&CW DROP O7 1/2'H&CW UP SO 2'V UP FROM BELOW O1/2'CW DROP 10 1/2'H&CW DROP 11 1-1/2'V UP FROM BELOW 12 I/2'H&CW UP FROM BELOW 13 1/2'CW UP FROM BELOW 14 3' SCHED. 40 PVC FLUE VENTS UP AVALON BEACH MODEL C 6408 OCEAN ESTATES COURT HUTCHINSON ISLAND FORT PIERCE, FLORIDA Key Plan: Issues: No.: Date: Description: 1. 2/13/12 FINAL ARCHITECT: Atelier d'Architecture By J. L. Ray, LLC 912 22nd Place Vero Beach, Florida 32960 (I IG) mo-lbll cell SEAL: )(`awing Title: 1 ST FLOOR PLUMBING PLAN M- AA Drn: Dwg. File: J.L.R. Chd: Project No J.L.R. 1119 Sheet No.: Reg, No.: AA26001760^ r 0 Lic. No.: AR94653 ICJ Date SigneFEB 16 0 CMYKght © 2011. MOW, J'Archit.d.r• 8, L L. Roy. LLC F — — — — L_ PLUMBING FIXTURE SCHEDULE MASTER BEDROOM - 2'W ON _SE 3/4 H CW DROP[ SITTING ROOM BSI 3'S IN 3'S ON i ---1- 1-1/4' -L WC L3/4' LAV -1/2' HIS 3'S DN MASTER BATW 'W IN HIS MASTER ---BATH --- A M' BD HER BATH W-0 �1-1/2-v 2 4' 2'V UP 3 1 I� hi DN CW UP BELOW HER FD COVERED WALKWAY FOYER /1-2'V UP r --I— —�I I NKEY NOTES 3,s DN, — UP TO WC 13 O3'S 1 1/2'CW UP T— O2'W UP TO LAV 1/2'H&CW UP O2'W UP TO SH 1/2'H8,CW UP UP TO TUB/SH O2'W 1/2'H&CW UP 2 ODN 5 1-1/2'V RISE 1-1 1/2'H&CW DROP IN O1-1/2'W 6 1-1/2'V RISE 1/2'H&CW DROP O1/2'H&CW UP 80 2'V UP FROM BELOW O9 1/2'CW DROP 10 1/2'H&CW DROP 11 1-1/2'V UP FROM BELOW 12 V2'H&CW UP FROM BELOW 13 1/2'CW UP FROM BELOW 14 3' SCHED, 40 PVC FLUE VENTS UP FDCfURE ED FD(TURE MFG: DESCRIPTION TYPE AND MODE TRIM / FAUCET SUPPLY TRAP PIPE SIZES REMARKS HOT COLT) WASTE VENT we WATER CLOSET KOHLER BY - McGUIRE — INTEGRAL - 1/2• 3- 1-1/2- WHITE VITREOUS CHINA. PROVIDE WITH ELONGATED SEAT W/ COVER. TANK TYPE OR EQUAL OWNER OR EQUAL WC -A WATER CLOSET (ADA) KOHLER BY - McGUIRE INTEGRAL - 1/2- 3' TANK TYPE OR EQUAL OWNER OR EQUAL BD BIDET KOHLER OR EQUAL BY OWNER BY OWNER McGUIRE INTEGRAL 1/2" 1/2" 2- 1-1/2- WHITE VITREOUS CHINA. 17" HIGH, PROV. WITH ELONGATED SEAT W/ COVER OR EQUAL LAV LAVATORY KOHLER BY BY McGUIRE McGUIRE 1/2" 1/2- 1-1/2- 1-1/2" WHITE VITREOUS CHINA UNDERCOUNTER MOUNT OR EQUAL OWNER OWNER OR EQUAL OR EQUAL CS COUNTER SINK KOHLER BY BY McGUIRE McGUIRE 1/2„ 1/2- 1-1/2" 1-1/2' OR EQUAL OWNER OWNER OR EQUAL OR EQUAL TUB BATHTUB KOHLER BY BY McGUIRE McGUIRE 1/2" 1/2- 2- 1-1/2- OR EQUAL OWNER OWNER OR EQUAL OR EQUAL SH SHOWER KOHLER BY BY McGUIRE McCUIRE 1/2" 1/2' 2' 1-1/ 2" OR EQUAL OWNER OWNER OR EQUAL OR EQUAL SH-1 SHOWER REFER TO BY GC BY McGUIRE McGUIRE 1/2' 1/2" 2- 1-1/2- ARCH DWGS OWNER OR EQUAL OR EQUAL TUB/SH BATHTUB KOHLER BY BY McGUIRE McGUIRE 1/2• 1/2- 2• 1-1/2„ SHOWER OR EQUAL OWNER OWNER OR EQUAL OR EQUAL KS KITCHEN KOHLER OR EQUAL BY BY McGUIRE McGUIRE 1/2' 1/2- 2" 1-1/2" UNDERCOUNTER MOUNT, EXTEND HW AND WASTE TO DISHWASHER, EXTEND CW TO ICE MAKER SINK OWNER OWNER OR EQUAL OR EQUAL LS LAUNDRY KOHLER BY BY McGUIRE McGUIRE 1/2' 1/2" 2" 1-1/2- SINK OR EQUAL OWNER OWNER OR EQUAL OR EQUAL PS PANTRY SINK KOHLER BY BY McGUIRE McGUIRE 1/2" 1/2' 1-1/2' 1-1/2- OR EQUAL OWNER OWNER OR EQUAL OR EQUAL WOB WASHER OUTLET BOX GUY GRAY BY BY - McGUIRE 1/2' 1/2- 2- 1-1/20 RECESS IN WALL W/ SHOCK ARRESTORS AND SINGLE LEVER WATER SHUT-OFF OR EQUAL OWNER OWNER OR EQUAL NOTES: 1. ALL FIXTURES AND APPURTENANCES SHALL COMPLY WITH THE STANDARDS SET FORTH IN THE FLORIDA PLUMBING CODE. 2. REFER TO THE ARCHITECTS DRAWINGS FOR LOCATION AND QUANTITIES OF ALL FIXTURES. 3. OWNER TO SELECT ALL FIXTURES AND TRIM. ALL FIXTURES TO BE INSTALLED BY THE PLUMBING CONTRACTOR. ID WC G 1ES61B LAV 2'/ 0 SITTING 3' SCHED 40 PVC AIR INTAKE & EXHAUST FOR DWH- SEE DETAIL F -1 2'VTR GUEST BEDROOM ARE THESE 1'LANje ,S AND ALL PROPOSED REQUIF"f, C i9OANYCORRF.CTION OR;: VAY BE . ELI N:'pECTORS THAT COMPLY ESSARY FJ ORDER TO WITH ALL APPLIgA'R Cpp6S, 7 GUEST BEDROOM EQUIPMENT SCHEDULE GENERAL DESIGN DATA ELECTRICAL ITEM SERVICE I MFR, No. LOCATION CAPACITY UM KW/HP R.P.M. VOLTS PHASE HZ, REMARKS DWG ELECRC WATER HEATER RHEEM OR EQUAL 83VR80-2 LAUNDRY ROOM 2nd FLOOR 80 GAL --- 4.5KW --- I 240v (1) 60 21 PH RECOVERY O 90' RISE I C P CIRC PUMP TACO OR EQUAL SERIES 003-BC4 AT DWH-1 & DWH-2 4 GPM 12 FT. 1/40-HP 3250 115V (1) 60 BRONZE CASING BRONZE FLANGED 1 XT EXPANSION TANK AMTROL OR EQUAL ST-5C AT DWH-1 & DWH-2 2.1 GAL. --- --- --- --- --- --- PROVIDE ISOLATION VALVE & UNION CONNECTION CINH ELECTRIC WATER HEATER RHEEM OR EQUAL 83VR40-2 GARAGE 40 GAL --- 4.5 KW --- 208v (1) 60 21 GPH RECOVERY O 90 RISE 2 Project: AVALON BEACH MODEL - C 6408 OCEAN ESTATES COURT HUTCHINSON ISLAND FORT PIERCE, FLORIDA Key Plan: Issues: No.: Date: Description: 1. 2/13/12 FINAL ARCHITECT: Atelier d'Architecture By J. L. Ray, LLC 912 22nd Place Vero Beach, Florida 32960 (772) 766-1611 cell SEAL: Drawing Title: 2ND FLOOR PLUMBING PLAN 0, Drn: Dwg. File: J.L.R. Chd: Project No.: J.L.R. 1119 Sheet No.: Reg. No.: AA26001760 Lic. No.: AR94653 A P2.1 0 Date Signq'EB 16 Cwyi4ht © 2011, Atelier dArchit,,Wre By J. L Roy, LLC 'roject: THERMOMETER 1-1/4' AQUASTAT--\ a` I i 3/4'— — — eX SPILL 1' DRAIN OVER F,D, OR TO OUTSIDE 13iZ1111111»I UNION (TYPE) TEMP. & PRESS RELIEF VALVE - PIPE FULL �SIZE TO DRAIN CI DRAIN PAN FOR DWH-1 CONC. PAD for DWH-2 GAS FIRED DIRECT VENT WATER HEATER DETAIL N. T. S. 2'V UP FROM BELOW- 3'VTR CAST IRON CLEi WITH COVER F1 DUTY REQUIRED. CAST IRON LONG SWEEP r' BEND OR CAST IRON COMB., 'Y' & w BEND. (USE REDUCING TYPE WHERE REQUIRED). BUILDING DRAIN OR SEWER MATERIAL AND SIZE AS SPECIFIED ETAIL 0 N. T. S. aY .Li u*rr+i.1! aJQrORi ti1i•ieY li{i,i v">rLN .�• 1/2'CW UP FROM BELOW FINISHED FLOOR CAST IRON EXTENSION - SAME SIZE AS SEWER UP TO 4' DIA, DIRECTION OF FLOW NOTEI PROVIDE WATER HAMMER ARRESTORS ON SUPPLY LINES. HOSE BIBB SUPPLY FITTINGS - FINISHED FLOOR tL m a x 0 Of a a HOT COLD 2' P-TRAP WASHING MACHINE ROUGH -IN UNIT 2' STAND PIPE 12' x 12' ACCESS PANEL CLEANOUT 1-1/2' VENT 2' DRAIN TO SAN, SEWER CLEANOUT DECKPLATE WASHER OUTLET BOX DETAIL N. T. S. AVALON BEACH MODEL- C 3408 OCEAN ESTATES COURT �UTCHINSON ISLAND =ORT PIERCE, FLORIDA Key Plan: Issues: No.: Date: Description: 1. 2/13/12 FINAL ARCHITECT: Atelier d'Architecture By J. L. Ray, LLC 912 22nd Place Vero Beach, Florida 32960 (772) 770-9622 ph/fax (772) 766-1611 cell CCAI . 3RD FLOOR PLUMBING PLAN Reference North Drn: Dwg. File: J.L.R. Chd: Project No.: J.L.R. 1119 Sheet No.: Req. No.: NAA2601760 P 3 10 Lic. o.: AR946g53e� Date Sign�p 1 6 LO Copyright © 2011, Atelier d'Architeclure By J. L Ray, LLC Project: 3" VTR-\ SANITARY RISER N. T. S. DIAGRAMS SECONDARY REGULATOR <a TOT, LOAD= 390,000 BTU/H TOT. RUN= 120 FT. OUTLET PRESS= 11.0 In. w,c, see, 1' 1' PRESS. DROP= 0.5 IN. W,C, SPEC. GRAY: 1.50 3/4' —1/2' LP TANKS CBY LI SUPPLIER) za TO 45KW GENERAC _ 290,000 GENERATOR BTU/HR 3/4' (100% LOAD) SAS RISER DIAGRAM Ee WORK 'IONS S THAT f0 CODER. AVALON BEACH MODEL C 6408 OCEAN ESTATES COURT HUTCHINSON ISLAND FORT PIERCE, FLORIDA Key Plan: Issues: No.: Date: Description: 1. 2/13/12 FINAL ARCHITECT: Atelier d'Architecture By J. L. Ray, LLC 912 22nd Place Vero Beach, Florida 32960 (772) 770-9622 ph/fax (772) 766-1611 cell sr Drawing Title: PLUMBING RISERS Reference North 7W Drn: Dwg. File: J.L.R. Chd: Project Nc J.L.R. 1119 Sheet No.: Reg. No.: AA26001760 0 EB 1 2 Lic. Na.: AR94653 94653 Date Signed:s t Cmialght © 2W1. Atelier d'Architecture By J. L Ray, LLC