Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONId REC OV EDD NOV 0 4 2016 [FjFjo.c. BY sducle counb/ Sal BRENT A WOOD ARCH ITECTU RE #3 Narrative i Application No.: 1506-0473 Application Type: Residential Addition Applicant: Mrs. Patricia Johnson Primary Contractor: First Florida Development ar 200 NE Dixie Hwy. Stuart, FL.34994' Phone: (772) 692-1387 Summary of Structural November 03, 2016 TCL Q- I .UU - rQl llQI FUUI IUQ LIU[I rI1011 • Revised & simplified structural foundation columns & beam configuration. • Re -alignment of covered walkway & Porte Cochere structure. • Revised window sizes in Garage 115 & Foyer 114. Sheet S-2.00 — Partial Foundation Plan • Revised & simplified structural foundation columns & beam configuration. • Re -alignment of covered walkway & Porte Cochere structure. • Added niche in Entry Foyer 1121. • Revised stair footing. Sheet S-3.00 — Partial Second Floor Framing Plan • Revised & simplified structural foundation columns & beam configuration. • Re -alignment of covered walkway & Porte Cochere structure. • Revised window sizes in Garage 115 & Foyer 114. • Eliminated timber framing over Exercise Room 111 and revised to Pre - Engineered truss system Sheet S-4.00 — Partial Second Floor Framing Plan • Revised & simplified structural foundation columns & beam configuration. • Re -alignment of covered walkway & Porte Cochere structure. • Revised window sizes in Garage 115 & Foyer 114. 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawoodarch.com fax772.419.5061 I BRENT A WOOD ARCH IITECTURE �I Sheet S-5.00 — Partial Roof Framing Plan • Re -alignment of covered walkway structure. • Eliminated timber framing over covered walkway and revised to Pre - Engineered truss system. • Simplified high roof over covered walkway. Sheet S-6.00 — Partial Roof Framing Plan • Eliminated timber framing over covered walkway and revised to Pre - Engineered truss system. , • Simplified high roof over covered walkway Sheet S-7.00 — Notes & Details • Revised structural column type. Sheet S-8.00 — Notes & Details • Revised structural beam schedule & types. Sheet S-11.00 — Sections & Details • Revised structural beam detail. Sheet S-12.00 — Sections & Details • Revised structural truss & beam details. Sheet S-13.00 — Sections & Details Revised structural truss & beam details. Architectural Sheet CV-1 — Cover Sheet • Revised drawing index indicating the sheets revised. Sheet A-1.00-1 —Architectural Site Plan • Relocation of proposed Hoot Aerobic Septic System. • Relocation of proposed Drain Field. Sheet A-1.00-2 — Ground Level Reference Floor Plan • Added exterior door to Electrical Room 116. • Revised window sizes in Garage 115 & Foyer 114. • Indication of proposed Hoot Aerobic Septic System. 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawoodarch.com fax772.419.5061 I I I BRENT A WOOD ARCH IITECTU RE I Sheet A-1.00-4 — Site Grading & Drainage Plan • Relocation of proposed Hoot Aerobic Septic System. • Relocation of proposed Drain Field. Sheet A-1.01-1 — Ground Level Floor Plan — Existing Residence Renovation and Additions I, • Added exterior door to Electrical 'Room 116. • Revised window sizes in Garage I115 & Foyer 114. • Indication of proposed Hoot Aerobic Septic System. I Sheet A-1.01-2 — Ground Level Dimension Plan — Existing Residence Renovation and Additions • Added exterior door to Electrical Room 116. • Revised window sizes in Garage 115 & Foyer 114. • Indication of proposed Hoot Aerobic Septic System. • Revised dimensions to reflect new; & revised openings. Sheet A-1.02-3 — Second Floor Reflected i Ceiling Plan • Revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system at Covered Walkway 211. Sheet A-1.12-3 — Second Floor Reflected ;Ceiling Plan • Revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system at Covered Walkway 211. Sheet A-1.03 — Overall Roof Plan • Revision / simplification to high roof section on Covered Walkway 211. • Added dimensions to high roof section on Covered Walkway 211. Sheet A-2.01 — Buildinq Elevations • Revision / simplification to high roof section on Covered Walkway 211. • Revision to Fascia member size on new construction. • Revised railing type in two locations on arrival side of house. • Added exterior door to Electrical Room 116. • Revised window sizes in Garage 115 & Foyer 114. Sheet A-3.01 — Buildinq Sections 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawoodarch.com fax772.419.5061 I W BRENT A WOOD ARCHITECTURE • Revision / simplification to roof section on Covered Walkway 211 - revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system at Covered Walkway 211. • Revision to Fascia member size ,on new construction. • Revised railing type. • Added note for furring @ bottom;of truss systems for T&G ceilings. • Added not for skirt board trim & flashing @ face of garage beam. • Revised ceiling cavity insulation from rigid to sprayed foam. Sheet A-3.02 — Building Sections • Revision / simplification to roof on Covered Walkway 211 - revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system at Covered Walkway 211. • Revision to Typical Eave / Fascia Detail — revised fascia member size on new construction. Revised elevator type — from Traction to Hydraulic Revised ceiling cavity insulation from rigid to sprayed foam. Sheet A-3.04 — Buildinq Sections • Revised ceiling cavity insulation from rigid to sprayed foam. • Revision to Typical Eave / Fascia Detail — revised fascia member size on new construction. Indication of existing stone veneer to remain (currently exterior of existing house to be enclosed by new covered walkway structure). Sheet A-3.05 — Buildinq Sections • Revision / simplification to roof on Covered Walkway 211 - revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system at Covered Walkway 211. • Revision to Typical Eave / Fascia Detail — revised fascia member size on new construction. • Revised ceiling cavity insulation from rigid to sprayed foam. • Indication of existing stone veneer to remain (currently exterior of existing house to be enclosed by new covered walkway structure). Sheet A-3.06 — Buildinq Sections 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawoodarch.com fax772.419.5061 11, BRENT A WOOD ARCHITECTURE • Revision / simplification to roof on Covered Walkway 211 - revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system at Covered Walkway 211. • Revision to Typical Eave / Fascia Detail — revised fascia member size on new construction. • Revised ceiling cavity insulation from rigid to sprayed foam. • Indication of existing stone veneer to remain (currently exterior of existing house to be enclosed by new covered walkway structure). Sheet A-3.07 — Building Sections • Revision / simplification to roof on Exercise Room - revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system. • Revision to Typical Eave / Fascia ;Detail — revised fascia member size on new construction. • Revised ceiling cavity insulation from rigid to sprayed foam. Sheet A-5.01 — Enlarged Sections and Details • Revision / simplification to roof on Covered Walkway 211 - revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered, vaulted truss system at Covered Walkway 211. • Revision to Typical Eave / Fascia Detail — revised fascia member size on new construction. • Revised ceiling cavity insulation from rigid to sprayed foam. • Revision / simplification to roof on Exercise Room - revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system. Sheet A-6.01 — Door and Hardware Schedules • Added exterior door to Electrical Room 116. Sheet A-6.02 — Window Schedule and Window Types • Eliminated window type "D" from scope. • Added Window type "JJ" Sheet A-6.04 — Window Types • Revised Window Type "GG" • Added Window type "JJ" 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawoodarch.com fax772.419.5061 P C, i'� i, fi ED BRENT A OOD °�� °�°�° ARCHIT WECTURE Application No.: Application Type: Revision #3 Narrative 1506-0473 Residential Applicant: Mrs. Patricia John Primary Contractor: First Florida Deve' 200 NE Dixie Hwy. Stuart, FL 34994 Phone: (772) 692-1 Structural November 03, 2016 Sheet S-1.00 — Partial Foundation Plan • Revised & simplified structural foundation columns & beam configuration. +� • Re -alignment of covered walkway & Porte Cochere structure. ✓ • Revised window sizes in Garage 1 115 & Foyer 114. T- Q-EvtsvP a Ac-9404 Sheet S-2.00 — Partial Foundation Plan i • Revised & simplified structural fouridation columns & beam configuration. ✓ • Re -alignment of covered walkway & Porte Cochere structure... • Added niche in Entry Foyer 121.✓ • Revised stair footing. ,r Sheet S-3.00 — Partial Second Floor Framing Plan • Revised & simplified structural foundation columns & beam configuration:✓ • Re -alignment of covered walkway & Porte Cochere structure. ►� • Revised window sizes in Garage 115 & Foyer 114. f-l' W5 4 V%..; l�`� • Eliminated timber framing over Exercise Room 111 and revised to Pre - Engineered truss system j g3 bn.a�+ �s_ j �r►g b,�''.�� Sheet S-4.00 — Partial Second Floor Framing Plan • Revised & simplified structural foundation columns & beam configuration. ✓ • Re -alignment of covered walkway & !Porte Cochere structure. ✓ • Revised window sizes in Garage 115 & Foyer 114. jcjg,,s rl } 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawooda'rch.com fax772.419.5061 _} . BRENTI A WOOD ARCH ITECTU RE ML v-U.vv— raIuai rwvi nannny rian • Re -alignment of covered walkway structure. •� • Eliminated timber framing over covered walkway and revised to Pre - Engineered truss system. 'I"rwys�d '�^°�g ti.�� r �`S °��I` aVV4 IIJ mac. • Simplified high roof over covered'walkwayIL .1u.1(�t�.2 7Cly-V.UV - f QIIIQI 11UV1 r-IQIIIIIIl1 r"IQII • Eliminated timber framing over covered walkway and revised to Pre - Engineered truss system. sf �1 ems 1 • Simplified high roof over covered walkway Sheet S-7.00 — Notes & Details • Revised structural column type.v, Sheet S-8.00 — Notes & Details • Revised structural beam schedule & types. ✓ Sheet S-11.00 — Sections & Details ✓ i • Revised structural beam detail. Sheet S-12.00 — Sections & Details V • Revised structural truss & beam details. Sheet S-13.00 — Sections & Details / Revised structural truss & beam details. Architectural Sheet CV-1 — Cover Sheet ✓ i • Revised drawing index indicating the sheets revised. Sheet A-1.00-1 —Architectural Site Plan • Relocation of proposed Hoot Aerobic Septic System. • Relocation of proposed Drain Field. Sheet A-1.00-2 — Ground Level Reference Floor Plan • Added exterior door to Electrical Room"116. M(C' • Revised window sizes in Garage 115 &, Foyer 114. • Indication of proposed Hoot Aerobic Septic System. J-,,W TZ 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawoodarch:com fax772.419.5061 2 e B R E N T I A WOOD A R C H I T E C T U R E 7Gl r%-1.VV--►— VIIG VIQU111y cx L"QlI IQyG r1011 • Relocation of proposed Hoot Aerobic Septic System. • Relocation of proposed Drain Field Additions • Added exterior door to Electrical Room 116. ✓ �4cs�� • Revised window sizes in Garage 115 & Foyer 114.," • Indication of proposed Hoot Aerobic Septic System. l' Sheet A-1.01-2 — Ground Level Dimension Plan — Existing Residence Renovation and Additions • Added exterior door to Electrical Room 116. • Revised window sizes in Garage 115 & Foyer 114. • Indication of proposed Hoot Aerobic Septic System. • Revised dimensions to reflect new & revised openings.✓ Sheet A-1.02-3 — Second Floor Reflected Ceiling Plan • Revised ceiling and beam heights to'reflect the elimination of heavy timber framing -and the addition of new pre-engineered vaulted truss system at Covered Walkway 211. m e,,d T"0 tiffs 'f— Sheet A-1.12-3 — Second Floor Reflected Ceiling Plan • Revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system at Covered Walkway 211. �p t 6 Sheet A-1.03 — Overall Roof Plan • Revision / simplification to high roof section on Covered Walkway 211. • Added dimensions to high roof section on Covered Walkway 211.. SVb� QnAd�� if Sheet A-2.01 — Building Elevations �cAm Tab c Yw�.�4'e %� T-Aj4 . • Revision / simplification to high roof section on Covered Walkway 211. • Revision to Fascia member size on new construction. • Revised railing type in two locations on arrival side of house. • Added exterior door to Electrical Room 1, 16. • Revised window sizes in Garage 115 & Foyer 114. Sheet A-3.61 — Building Sections 20 SE OCEAN BLVD. STUART, - FLORIDA 34996 772.220.1217 brent@bawoodarch.com fax772.419.5061 " 3 I BRENT�' A WOOD A R C H I T E C T U R E • Revision / simplification to roof section on Covered Walkway 211 - revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system at Covered Walkway 211. • Revision to Fascia member size on new construction. • Revised railing type. • Added note for furring @ bottom of truss systems for T&G ceilings. • Added not for skirt board trim & flashing @ face of garage beam. • Revised ceiling cavity insulation from rigid to sprayed foam. I Sheet A-3.02 — Buildinq Sections • Revision / simplification to roof on Covered Walkway 211 - revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered it aulted truss system at Covered Walkway 211. • Revision to Typical Eave / Fascia Detail — revised fascia member size on new construction. • Revised elevator type — from Traction to Hydraulic • Revised ceiling cavity insulation from rigid to sprayed foam. t Sheet A-3.04 — Buildinq Sections • Revised ceiling cavity insulation from lrigid to sprayed foam. • Revision to Typical Eave / Fascia Detail — revised fascia member size on new construction. • Indication of existing stone veneer to temain (currently exterior of existing house to be enclosed by new covered,Iwalkway structure). i Sheet A-3.05 — Buildinq Sections • Revision / simplification to roof on Covered Walkway 211 -revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system at Covered Walkway 211. Revision to Typical Eave / Fascia Detail — revised fascia member size on new construction. Revised ceiling cavity insulation from rigid to sprayed foam...�{;C Indication of existing stone veneer to remain (currently exterior of existing house to be enclosed by new covered walkway structure). Sheet A-3.06 - Buildinq Sections 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawoodarch.com fax772.419.5061 G , .It ..r . BRENT IA WOOD ARCH ITECTU RE • Revision / simplification to roof one Covered Walkway 211 - revised ceiling v/ and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system at Covered Walkway 211. I Revision to Typical Eave / Fascia Detail — revised fascia member size on new construction. -- Revised ceiling cavity insulation from rigid to sprayed foam. GY"� • Indication of existing stone veneer to remain (currently exterior of existing house to be enclosed by new covered walkway structure). Sheet A-3.07 — Building Sections • Revision / simplification to roof on Exercise Room - revised ceiling and ✓ beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system.] p tom. • Revision to Typical Eave / Fascia Detail — revised fascia member size on new construction.' ol'c • Revised ceiling cavity insulation from rigid to sprayed foam. Sheet A-5.01 — Enlarged Sections and Details • Revision / simplification to roof on Covered Walkway 211 -revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system at Covered Walkway 21.1. Revision to Typical' / Fascia Detail — revised fascia member size on new construction. Revised ceiling cavity insulation from rigid to sprayed foam. Revision / simplification to roof on Exercise Room - revised ceiling and beam heights to reflect the elimination of heavy timber framing and the addition of new pre-engineered vaulted truss system. ✓ I Sheet A-6.01 — Door and Hardware Schedules • Added exterior door to Electrical Room 116. Sheet A-6.02 —Window Schedule and Window Types • Eliminated window type "M from scope. • Added Window type "JJ" Sheet A-6.04 — Window Types • Revised Window Type "GG" • Added Window type "JJ° 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawoodarchxoml fax772.419.5061 ECE!VED JAN. 17 2017 BRENI A WOOD PERMITTING A R C H I T E C T U R E st. Lucie County, FL St. Lucie County Building Department Revision 3 - Responses to Building Department Comments January 16, 2015 Permit No.: 1506-0473 Application Type: Residential Addition Applicant: Mrs. Patricia Johnson Primary Contractor: First Florida Development and Construction, Inc. 200 NE Dixie Hwy. Stuart, FL 34994 Phone: (772) 692-1387 COMMENT: 1. SUBMIT THE PRODUCT APPROVALS, IN DUPLICATE OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.842 OF THE FLORIDA STATUTES. RESPONSE: Please refer to the attached (2) copies of completed Product Review Affidavit signed & sealed by architect of record. COMMENT: 2. NOTE: IF SUBMITTING 2 COPIES OF PRODUCT APPROVAL'S (I.E. N.O.A. OR STATE OF FLORIDA APPROVAL) IN LUE OF THE PRODUCT APPROVAL AFFIDAVIT DOCUMENTS MUST BE HIGHLIGHTED OR MARKED IDENTIFYING THE OPENING OR CLADDING COMPONENTS, WITH FASTENERS AND DESIGN PRESSURES. RESPONSE: Please refer to the attached (2) copies of completed Product Review Affidavit signed & sealed by architect of record. COMMENT: 3. PLEASE SUBMIT PRODUCT APPROVALS FOR THE SKY LIGHTS MEETING THE REQUIREMENTS OF SECTION 402.1.1 SUBSECTION B. RESPONSE: Please refer to the attached (2) copies of completed Product Review Affidavit signed & sealed by architect of record 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brentgbawoodarch.com fax772.419.5061 BRENT A WOOD ARCHITECTURE COMMENT: 4. GLAZING AND THERMAL CHANGES'. PLEASE FURNISH ENEGRY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 OF THE 2014 FLORIDA ENEGRY�-CODE FIFTH EDITION. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER. RESPONSE: Please refer to attached revised energy calculations & Manual J forms. COMMENT: 5. PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE FOR THE NEW ROOFING SYSTEMS. REVIEWED AND APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE. RESPONSE: Please refer to the truss placement drawings reviewed & approved by the structural engineer of record. COMMENT: 6. PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE FOR THE NEW ROOFING SYSTEMS. PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE. RESPONSE: Please refer to the truss engineering reviewed & approved by the structural engineer of record. COMMENT: 7. PLEASE SUBMIT DOCUMENTS FOR THE NEW ELEVATOR HOISTING SYSTEM. SEE SECTION 107 OF THEE 2014 FBC. RESPONSE: Please refer to the attached elevator manufacturer hoistway details & specifications. COMMENT: 8. PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. RESPONSE: Noted. 20 SE OCEAN BLVD. STUART, . FLORIDA 34996 772.220.1217 brent(abawoodarch.com fax772.419.5061 r IIA"Aa BRENT A WOOD ARCH ITECTU RE St. Lucie County Building Department Revision 1 - Responses to Zoning Comments August 20, 2015 Permit No.: 1506-0473 ' Application Type: Residential Addition Applicant: Mrs. Patricia Johnson Primary Contractor: First Florida Development and Construction, Inc. 200 NE Dixie Hwy. Stuart, FL 34994 Phone: (772) 692-1387 COMMENT: 1. ALL SETS OF PLANS NEED TO BE SIGNED OFF AND APPROVED BY ST LUCIE COUNTY HEALTH DEPARTMENT RESPONSE: All plans have been submitted to St. Lucie County Health Department for review and are pendina approval. G.C. to provide confirmation of reauired approval COMMENT: 2. ON THE BUILDING PERMIT APPLICATION IDENTIFY THE TOTAL SQUARE FOOTAGE OF THE EXISTING HOUSE AND TOTAL SQUARE FOOTAGE OF PROPOSED ADDITION. RESPONSE: Please refer tc h COMMENT: 3. PROVIDE A SIGNED AND SEALED BOUNDARY/TOPO SURVEY SHOWING EXISTING AND PROPOSED IMPROVEMENTS. SHOW ALL PROPOSED BUILDING SETBACKS. PROVIDE EXISTING. FINISHED FLOOR AND PROPOSED FLOOR ELEVATIONS. THE PROPOSED ELEVATIONS SHALL BE A MINIMUM OF 18 INCHES ABOVE THE ELEVATION AT THE CROWN OF THE ROAD. PROVIDE ELEVATION AT CROWN OF ROAD. RESPONSE: 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawoodarch.com fax772.419.5061 1 \ 7 Please refer to Revised Boundary/Topographical Survey signed & sealed by Surveyor of record. COMMENT: 4. REMOVE ALL REFERENCES TO A GUEST HOUSE ON THE PLANS AND BUILDING PERMIT. THE IMPROVEMENTS ARE ALL CONNECTED AND WILL BE CONSIDERED AN ADDITION TO THEISINGLE FAMILY RESIDENCE. RESPONSE: All references to "Guest "Arirlifinn" _ Ploncn rcfc COMMENT: 5. REVISE THE PLANS TO SHOW EXISTING SEPTIC AND DRAINFIELD LOCATIONS AND PROPOSED SEPTIC AND DRAINFIELD LOCATIONS. WILL THE SEPTIC AND DRAINFIELD BE NEW OR IS THIS A MODIFICAITON TO EXISTING? RESPONSE: Please refer to Revised Boundary/Topographical Survey & Architectural Site Plan; sheet A-1.00-1, indicating the locations of existing and proposed septic system & drain field components. The Proposed Septic & drain field components are to be New. COMMENT: 6. AS OF 7/14/2015 NO VEGETATION REMOVAL PERMIT HAS BEEN SUBMITTED. BEN BALCER RESPONSE: Vegetation removal application to be submitted by General Contractor. COMMENT: 7. RELOCATE NEW SEPTIC SYSTEM 300 LF FROM THE MEAN HIGH WATER LINE OF THE ST. LUCIE RIVER OR APPLY FOR A ADMINISTRATIVE SHORELINE VARIANCE FROM THE PROVISIONS OF LDC SECTION 6.02.02 (B)(2)(A). NO NEW SEPTIC SYSTEMS WITHIN 300 FEET OF THE SHORELINE. RESPONSE: New HOOT aerobic tvpe septic system to be used for this project. Svstem specifications to be submitted to Health Department for approval and an Administrative Shoreline Variance will be applied for by coastal/civil engineer subsequent to comment responses. 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawoodarch.com fax772.419.5061 BRENT A WOOD ARCHITECTURE COMMENT: 8. PLEASE FURNISH ENEGRY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 OF THE 2010 FLORIDA ENERGY CODE. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER. RESPONSE: ' Please refer to enerav calculations & Manual J forms signed by engineer of record. COMMENT: 9. ENERGY CALCS MUST BE SIGNED BY OWNER OR OWNERS AGENT. i RESPONSE: Please refer to energy calculations & Manual J forms sinned by owners agent. COMMENT: 10. PLEASE ADD TO THE PLANS THE CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA WEATHERING ANDTERMITE AREA IN ACCORDANCE WITH TABLE 301.2.(1) RESPONSE: Please refer to revised drawing sheet: "GN-1" for requested data COMMENT: 11. PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES IN ACCORDANCE WITH SECTION 302.9 OF THE FLORIDA RESIDENTIAL CODE RESPONSE: Please refer to revised drawing sheet: "GN-1" for requested data COMMENT: 12. PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS REQUIRED IN SECTION 302.10 OF THE 2010 FLORIDA RESIDENTIAL CODE RESPONSE: Please refer to revised drawing sheet: "GN-1" for requested data COMMENT: 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brentgbawoodarch.com fax772.419.5061 13. PLEASE COMPLETE THE GAS PIPING SCHEMATIC WORK SHEET OR SHOW ON PLANS AS PER SECTION G2401 OF THE RESIDENTAL BUILDING CODE. RESPONSE: Schematic Worksheet" for exterior generator and fuel tanks at time of submittal. No interior gas systems or appliances are proposed for this rp oiect• COMMENT: 14. PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE RESPONSE: to manufacturer. ineer / COMMENT: 15. PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2010 FLORIDA BUILDING CODE RESPONSE: Truss engineering drawings will be provided prior to construction phase, subsequent to selection & contracting',of licensed truss engineer / manufacturer. COMMENT: 16. PLEASE FURNISH TRUSS STAPING IN DUPLICATE PER 107.2.1 OF THE 2010 FLORIDA BUILDING CODE RESPONSE: Truss engineering drawings will be provided prior to construction phase, subsequent to selection & contracting of licensed truss engineer / manufacturer. COMMENT: 17. PLEASE FURNISH PILE DETAIL ON PLANS FOR THE NEW PILE LOCATED UNDER THE NEW STAIRS. 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brent@bawoodarch.com fax772.419.5061 J BRENT A WOOD ARCHITECTURE RESPONSE: Please refer to revised structural', detail "A" on sheet S-1.00 COMMENT: 18. PLEASE FURNISH SOIL REPORT PER THE FOUNDATION NOTES ON PAGE S- 7.00 IN DUPLICATE.. RESPONSE: Requested Soils report is enclosed in duplicate with re -submittal package. COMMENT: 19. PLEASE CLARIFY 8" STEPDOWN AT GROUND LEVEL OF THE ELEVATOR SHAFT. RESPONSE: Elevator manufacturer specifications require an 8" elevator pit at the bottom of scheduled hoistway. Elevator specifications are provided to address subsequent comment. COMMENT: 20. PLEASE CLARIFY IF THE RAMP IN THE GARAGE IS BEING USED FOR WHEEL CHAIR ACCESS. IF SO PLEASE SEE SECTION 405 OF THE 2010 ACCESSIBILITY CODE. PLEASE PUT ON PLANS SLOPE OF THE RAMP. RESPONSE: Ramp in private garage is not intended for wheelchair use — ramp is intended for recyclables and trash removal. COMMENT: 21. PAGE A1.01-2 STAIR FOOT NOTES DETAIL LOCATION IS INCORRECT PLEASE CORRECT. RESPONSE: Please refer to revised sheet A-1.02-2 indicating proper stair detail location. COMMENT: 22. PLEASE FURNISH SPEC SHEETS FOR THE ELEVATOR. RESPONSE: Elevator manufacturer specifications are enclosed with the re -submittal package. 20 SE OCEAN BLVD. STUART, i FLORIDA 34996 772.220.1217 brentgbawoodarch.com fax772.419.5061 III BRENT A WOOD ARCH ITECTU RE COMMENT: 23. PLEASE FURNISH SPEC SHEETS FOR THE GENERATOR. RESPONSE: package. COMMENT: 24. PAGE S1.00 CALLS OUT FOR 10 PTiWOOD PILES, CROSS SECTION CALLS OUT FOR 12" PILES PLEASE CORRECT. RESPONSE: nl,....... _..a.._ a.. ,__&— _._ ..&.....a 9�- of nn 1........a ....�......... to be 12" diameter. COMMENT: 25. PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. RESPONSE: Noted 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brentnbawoodarch.com fax772.419.5061