HomeMy WebLinkAboutREVIEW-COMMENTSI -- Planning & Development Services f Building 8 Code Regulation Division. 2300 Virginia>Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462.6443 SCANNED BY St Lucie count I REVIEW COMMENTS Page 1 PROPERTY INFORMATION Address: 3354 Perimeter Rd Owner(s): Patricia A Johnson City / State / Zip: Stuart, FI 34995 Parcel #: 4436-510-0030-000/6 Jurisdiction: SAINT LUCIE COUNTY Zoning: AR-1 I Lot#: 26 Block: APPLICATION INFORMATION Permit Number: 1506-0473 I Stories: Automatic Sprinkler System? No Permit Type: BUILD RESID ADDITION CONTRACTOR INFORMATION Contractor Name: Fax Number: Business Name: Email: Business Addr: City I State I Zip: REVIEWS AND COMMENTS ReviewT-yoe Status Reviewed By Date Started Date Completed Date Released ENVIRONMENTAL REVIEW INCOMPLETE Ben Balcer 7/14/2015 Comment: AS OF 7/14/2015 NO VEGETATION REMOVAL PERMIT HAS BEEN SUBMITTED. BEN BALCER Comment: RELOCATE NEW SEPTIC SYSTEM 300 LF FROM THE MEAN HIGH WATER LINE OF THE ST. LUCIE RIVER OR 7/14/2015 APPLY FOR A ADMINISTRATIVE SHORELINE VARIANCE FROM THE PROVISIONS OF LDC SECTION 6.02.02(B) (2)(A). NO NEW SEPTIC SYSTEMS WITHIN 300 FEET OF THE SHORELINE. FRONT COUNTER REVIEW COMPLETE Angela Huff 6/26/2015 6/26/2015 6/26/2015 Comment: PE REVIEW COMMENTS (2) INCOMPLETE William Durden 8/31/2015 Comment: • ENERGY CALC'S MUST BE SIGNED BY OWNER OR OWNERS AGENT. 8/5/2015 ENERGY CALC SUBMITTED ONLY HAVE THE PREPARERS SIGNATURE ON THEM. Comment: • PLEASE COMPLETE THE GAS PIPING SCHEMATIC WORK SHEET OR SHOW ON PLANS AS PER SECTION 8/5/2015 G2401 OF THE RESIDENTAL BUILDING CODE. Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 8/5/2015 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE Comment: - PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2010 FLORIDA BUILDING 8/5/2015 CODE 8/5/2015 Comment: • PLEASE FURNISH TRUSS STAPING IN DUPLICATE PER 107.2.1 OF THE 2010 FLORIDA BUILDING CODE Comment: • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 8/5/2015 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. PLANS EXAMINER REVIEW COMPLETE William Durden 8/512015 8/31/2015 8/31/2015 Comment: R17/ ct Planning &Development Services Building & Code Regulation Division, 2300'Virginia Avenue FortPierce, FL. 34082 Phone:(772)462-2172 Fax:(772)462-6443 REVIEW COMMENTS 2 ZONING REVIEW INCOMPLETE Jeffrey Johnson 7/8/2015 7/8/2015 7/8/2015 Comment: ALL SETS OF PLANS NEED TO BE SIGNED OFF AND APPROVED BY ST LUCIE COUNTY HEALTH 7/8/2015 DEPARTMENT Comment: PROVIDE A SIGNED AND SEALED BOUNDARY/TOPO SURVEY SHOWING EXISTING AND PROPOSED IMPROVEMENTS. SHOW ALL PROPOSED BUILDING SETBACKS. PROVIDE EXISTING FINISHED FLOOR AND 7/8/2015 PROPOSED FLOOR ELEVATIONS. THE PROPOSED ELEVATIONS SHALL BE A MINIMUM OF 18 INCHES ABOVE THE ELEVATION AI THE CROWN OF THE ROAD. PROVIDE ELEVATION AT CROWN OF ROAD. Comment: REVISE THE PLANS TO SHOW EXISTING SEPTIC AND DRAINFIELD LOCATIONS AND PROPOSED SEPTIC 7/8/2015 AND DRAINFIELD LOCATIONS. WILL THE SEPTIC AND DRAINFIELD BE NEW OR IS THIS A MODIFICAITON TO EXISTING? Comment: ON THE BUILDING PERMIT APPLICATION IDENTIFY THE TOTAL SQUARE FOOTAGE OF THE EXISTING 7/8/2015 HOUSE AND TOTAL SQUARE FOOTAGE OF PROPOSED ADDITION. Comment: THE PROPOSED ADDITION WILL BE CONSIDERED A GUEST HOUSE AS PER COUNTY LAND DEVELOPMENT CODE REQUIREMENTS. PER SECTION 7.10.04 OF THE LAND DEVELOPMENT CODE, THE PROPERTY 8/6/2015 OWNER SHALL SIGN A NOTARIZED STATEMENT TO THE EFFECT THAT UNDER NO CIRCUMSTANCES SHALL THE GUEST HOUSE BE USED FOR RENTAL PURPOSES SEASONAL OR ANNUAL. Planning & Development Services Building & Code Regulation Division. 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 3354 Perimeter Rd City / State / Zip: Stuart, FI 34995 Parcel #: 4436-510-0030-000/6 Zoning: AR-1 APPLICATION INFORMATION Permit Number: 1506-0473 Permit Type: BUILD RESID ADDITION CONTRACTOR INFORMATION Contractor Name: Business Name: Business Addr: City / State / Zip: REVIEWS AND COMMENTS Review Tvoe ENVIRONMENTAL REVIEW 7/14/2015 Comment: Comment: 7/14/2015 FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW Comment: 8/5/2015 8/5/2015 Comment: 8/5/2015 Comment: 8/5/2015 Comment: 8/5/2015 Comment: 8/5/2015 Comment: Comment: 8/5/2015 8/5/2015 Comment: REVIEW COMMENTS Page 1 Owner(s): Patricia A Johnson Jurisdiction: SAINT LUCIE COUNTY Lot#: 26 Block: i Stories: Automatic Sprinkler System? No I i i Fax Number: I Email: Status ;Reviewed By Date Started Date Completed Date Released PENDING AS OF 7/14/2015 NO VEGETATION REMOVAL PERMIT HAS BEEN SUBMITTED. BEN BALCER RELOCATE NEW SEPTIC SYSTEM 300 LF FROM THE MEAN HIGH WATER LINE OF THE ST. LUCIE RIVER OR APPLY FOR A ADMINISTRATIVE SHORELINE VARIANCE FROM THE PROVISIONS OF LDC SECTION 6.02.02(B) (2)(A). NO NEW SEPTIC SYSTEMS WITHIN 300 FEET OF THE SHORELINE. COMPLETE Angela Huff 6/26/2015 6/26/2015 6/26/2015 INCOMPLETE William Durden 8/5/2015 • PLEASE FURNISH ENEGRY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 OF THE 2010 FLORIDA ENEGRY CODE. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER. • ENERGY CALC'S MUST BE SIGNED BY OWNER OR OWNERS AGENT. • PLEASE ADD TO THE PLANS THE CLIMATIC AND GEOGRAPHIC DESIGN CRIERIA WEATHERING AND TERMITE AREA IN ACCORDANCE WITH TABLE 301.2.(1) - PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES IN ACCORDANCE WITH SECTION 302.9 OF THE FLORIDA RESIDENTIAL CODE • PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS REQUIRED IN SECTION 302.10 OF THE 2010 FLORIDA RESIDENTIAL CODE - PLEASE COMPLETE THE GAS PIPING SCHEMATIC WORK SHEET OR SHOW ON PLANS AS PER SECTION G2401 OF THE RESIDENTAL BUILDING CODE. • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2010 FLORIDA BUILDING CODE Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462.6443 REVIEW COMMENTS 8/5/2015 Comment: • PLEASE FURNISH TRUSS STAPING IN DUPLICATE PER 107.2.1 OF THE 2010 FLORIDA BUILDING CODE 8/5/2015 Comment: • PLEASE FURNISH PILE DETAIL ON PLANS FOR THE NEW PILE LOCATED UNDER THE NEW STAIRS. 8/5/2015 Comment: • PLEASE FURNISH SOIL REPORT PER THE FOUNDATION NOTES ON PAGE S-7.00 IN DUPLICATE. 8/5/2015 Comment: • PLEASE CLARIFY 8" STEPDOWN AT GROUND LEVEL OF THE ELEVATOR SHAFT. Comment: • PLEASE CLARIFY IF THE RAMP IN THE GARAGE IS BEING USED FOR WHEEL CHAIR ACCESS. IF SO 8/5/2015 PLEASE SEE SECTION 405 OF THE 2010 ACCESSIBILITY CODE. PLEASE PUT ON PLANS SLOPE OF THE RAMP. 1 8/5/2015 Comment: • PAGE A1.01-2 STAIR FOOT NOTES DETAIL LOCATION IS INCORRECT PLEASE CORRECT. 8/5/2015 Comment: • PLEASE FURNISH SPEC SHEETS FOR THE ELEVATOR. 8/5/2015 Comment: • PLEASE FURNISH SPEC SHEETS FOR THE GENERATOR. 8/5/2015 Comment: • PAGE S1.00 CALLS OUT FOR 10 PT WOOD PILES, CROSS SECTION CALLS OUT FOR 12" PILES PLEASE CORRECT. Comment: • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 8/5/2015 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. ZONING REVIEW INCOMPLETE Jeffrey Johnson 7/8/2015 7/8/2015 718/2015 Comment: ALL SETS OF PLANS NEED TO BE SIGNED OFF AND APPROVED BY ST LUCIE COUNTY HEALTH 7/8/2015 DEPARTMENT Comment: PROVIDE A SIGNED AND SEALED BOUNDARY/TOPO SURVEY SHOWING EXISTING AND PROPOSED 7/8/2015 IMPROVEMENTS. SHOW ALL PROPOSED BUILDING SETBACKS. PROVIDE EXISTING FINISHED FLOOR AND PROPOSED FLOOR ELEVATIONS. THE PROPOSED ELEVATIONS SHALL BE A MINIMUM OF 18 INCHES ABOVE THE ELEVATION AT THE CROWN OF THE ROAD. PROVIDE ELEVATION AT CROWN OF ROAD. I Comment: REVISE THE PLANS TO SHOW EXISTING SEPTIC AND DRAINFIELD LOCATIONS AND PROPOSED SEPTIC 7/8/2015 AND DRAINFIELD LOCATIONS. WILL THE SEPTIC AND DRAINFIELD BE NEW OR IS THIS A MODIFICAITON TO EXISTING? 7/8/2015 Comment: ON THE BUILDING PERMIT APPLICATION IDENTIFY THE TOTAL SQUARE FOOTAGE OF THE EXISTING HOUSE AND TOTAL SQUARE FOOTAGE OF PROPOSED ADDITION. Comment: REMOVE ALL REFERENCES TO A GUEST HOUSE ON THE PLANS AND BUILDING PERMIT. THE 7/8/2015 IMPROVEMENTS ARE ALL CONNECTED AND WILL BE CONSIDERED AN ADDITION TO THE SINGLE FAMILY RESIDENCE. I REVIEW COMMENTS :.: Page 2 -Comment: • PLEASE FURNISH TRUSS STAPING-IN DUPLICATE PER 107.2.1 OF THE 2010 FLORIDA BUILDING CODE 8/5%2015 Comment:. • PLEASE FURNISH:PILE DETAIL ON PLANS FOR THE NEW PILE LOCATED UNDER THE NEW STAIRS. 8/5/2015 Comment: -:PLEASE FURNISH SOIL -REPORT PER THE FOUNDATION NOTES ON PAGE S-7.00 IN DUPLICATE. 8/5l2015 Comment: • PLEASE'CLARIFY 8" ST i PDOWN AT GROUND LEVEL OF THE: ELEVATOR SHAFT. Comment: • PLEASE CLARIFY IF THE RAMP IN THE GARAGE IS BEING USED FORWHEEL CHAIR ACCESS. IF SO 8/5/2015 PLEASE SEE SECTION 40:5.OF THE 2010 ACCESS]BILITY:CODE. PLEASE PUT ON PLANS SLOPE OF THE :. RAMP. 8/5/2015 :Comment: • PAGE A1.01-2 STAIR FOOT NOTES -DETAIL LOCATION IS INCORRECT PLEASE CORRECT. 8/5/2015 Comment: • PLEASE FURNISH SPEC SHEETS FOR THE ELEVATOR. 815/2015 Comment: PLEASE FURNISH SPEC SHEETS FOR THE GENERATOR. 8/5/2015 Comment:.. • PAGE S1:00 CALLS OUT FOR 10 PT WOOD PILES, CROSS SECTION CALLS OUT FOR 12" PILES. PLEASE CORRECT. Comment: • PLEASE NOTE THAT THE COMMENTS'ARE FOR THE CLARIFICATION OR CORRECTION -OF THE 8/5/2015 SUBMITTED.DOCUMENTS: ADDITIONAL REVIEW MAYBE REQUIRED AFTER,SUBMITTING CORRECTED DOCUMENTS. ZONING REVIEW INCOMPLETE Jeffrey Johnson 7/8/2015 7/8/2015 7/8/2015 Comment: ALL SETS OF PLANS NEED To BE SIGNED OFF AND. APPROVED BYST LUCIE COUNTY HEALTH 7/8/2015 DEPARTMENT Comment: PROVIDE A SIGNED AND SEALED BOUNDARY/TOPO SURVEY SHOWING EXISTING AND PROPOSED 7/8/2015. IMPROVEMENTS. :SHOW ALL PROPOSED BUILDING SETBACKS. PROVIDE EXISTING FINISHED FLOOR AND ".: PROPOSED FLOOR ELEVATIONS. THE PROPOSED ELEVATIONS:SHALL BE A MINIMUM OF. 18 INCHES ABOVE THE,ELEVATION AT THE CROWN OF THE ROAD. PROVIDE ELEVATION AT CROWN OF ROAD., Comment: • : REVISE THE PLANS TOO SHOW EXISTING SEPTIC AND DRAINFIELD LOCATIONS AND PROPOSED SEPTIC 7/8/2015 AND DRAINFIELD LOCATIONS. WILL THE SEPTIC AND DRAINFIELD BE:NEW OR IS THIS A MODIFICAITON TO EXISTING? 7!8/2015 Comment: ON THE BUILDING PERMIT APPLICATION .IDENTIFY; THE TOTAL SQUARE FOOTAGE OF THE EXISTING, -TOTAL 'HOUSE AND SQUARE FOOTAGE OF PROPOSED ADDITION. Comment: REMOVE ALL REFERENCES TO A GUEST HOUSE ON THE PLANS AND.BUILDING PERMIT. THE, :7/8/2015 IMPROVEMENTS ARE ALL CONNECTED AND WILL BE CONSIDERED AN ADDITION TO THE SINGLE FAMILY .: RESIDENCE. .. ( Piarining'8develoorn6l5ervices REVIEW COMMENTS 9 9 hon D' Butid(n Ei;CodeRe u!a .,.; _nnsio,� 2300 Virginia Avsalue, .forfPierceFL 34982 Phone:11M1462 2172 Fax (i72)4M•6443 Page 1 PROPERTY INFORMATION Address: 3354 Perimeter Rd Ow ner(s): Patricia A Johnson City / State / Zip: Stuart, FI.:' 34995 Parcel#: 4436-510-0030-000/6 Jurisdiction: SAINT LUCIE COUNTY Zoning: ARA Lot#: 26. Block: . APPLICATION INFORMATION Permit Number: 1506-0473 :. Stories: Automatic Sprinkler System? No . Permit Type: BUILD;RESID ADDITION I CONTRACTOR INFORMATION I RE n77 . Contractor Name: Fax Number: Business Name: AEG 2 6 2015' Email: Business Addr: I ©ri(s Public !N City /State /Zip: St.. Lucie County, FI_ REVIEWS AND COMMENTS...' I Review Tvae Status Reviewed'Bv Date Started Date Completed: Date Released I ENVIRONMENTAL REVIEW ' PENDING 7/14/2015 Comment:. : AS OF 7/14/2015 NO VEGETATION REMOVAL PERMIT HAS BEEN SUBMITTED. BEN BALCER Comment: RELOCATE NEW SEPTIC SYSTEM 300 LF FROM THE MEAN HIGH WATERLINE OFTHE ST. LUCIE RIVER OR 7/14/2015 : APPLY FOR ADMINISTRATIVE SHORELINE VARIANCE. FROM THE PROVISIONS OF LDC SECTION 6.02:02 ,(B)(2)(A). NO -NEW SEPTIC SYSTEMS WITHIN 300 FEET OF THE SHORELINE. FRONT.COUNTER REVIEW COMPLETE.. Angela Huff .: 6/26/2015 : 6/26/2015 . 6/2612015 " Comment: I PLANS EXAMINER REVIEW INCOMPLETE William Durden 8/5/2015 -Comment: • PLEASE:FURNISH. ENEGRY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 8/5/2015 OF THE 2010 FLORIDp ENEGRY CODE. NOTE ONLY; ENERGIES MUST HAVE ORIGINAUSIGNATURE OF PREPARER. F4. 7�(2-d'C t° 2 8/5/2015 Comment: -ENERGY CALLS MUST BE SIGNED BY OWNER OR OWNERS AGENT. 8/5/2015 Comment: • PLEASE ADD TO THE, PLANS THE CLIMATIC AND GEOGRAPHIC DESIGN.CRIERIA WEATHERING AND TERMITE AREA IN -ACCORDANCE WITH TABLE 301.2.(1) 8/5/2015 Comment: •.PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED, INDEX FOR WALL AND CEILING FINISHES IN,ACCORDANCE WITH SECTION 302.9 OF THE FLORIDA RESIDENTIAL CODE 8/5/2015 Comment: • PLEASE.SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS REQUIRED IN SECTION 302.10 OF THE 2010 FLORIDA RESIDENTIAL CODE 8/5/2015 Comment: • PLEASE COMPLETE THE GAS PIPING SCHEMATIC WORK SHEET OR SHOW ON PLANS AS PER SECTION G2401 OF THE RE$IDENTAL BUILDING CODE. Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS -IN DUPLICATE REVIEWED AND 8/5/2015 APPROVED'BY THE_DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61 G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE 8/5/2015 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2010 FLORIDA BUILDING CODE Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL, 34982 Phone:(772)462-2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 3354 Nw Perimeter Rd City / State I Zip: Palm.City, FI 34990 Parcel #: 4436-510-0030-000/6 Zoning: AR-1 APPLICATION INFORMATION Permit Number: 1506-0473 Permit Type: BUILD RESID ADDITION REVIEW COMMENTS 1 Owner(s): Patricia A Johnson Jurisdiction: SAINT LUCIE COUNTY Lot#: 26 Block: Stories: Automatic Sprinkler System? No CONTRACTOR INFORMATION Contractor Name: Paul L Kleinfeld Fax Number: 772-692-2359 Business Name: First Florida Development & Construction Inc Business Addr: 200 Ne Dixie Hwy Email: Cindi@Firstfloridainc.Com City / State / Zip: Stuart, FI 34994 REVIEWS AND COMMENTS { Review Tvoe Status Reviewed By Date Started Date Completed Date Released i ENVIRONMENTAL REVIEW COMPLETE Ben Balcer 7/8/2015 3/2/2016 3/2/2016 Comment: I FRONT COUNTER REVIEW COMPLETE Angela Huff 6/26/2015 3/2/2016 3/2/2016 i Comment: NOTIFIED FOR PICK UP COMPLETE Deanna Givens 302016 3/2/2016 3/2I2016 Comment: PE REVIEW COMMENTS (2) COMPLETE William Durden 8/31/2015 2/23/2016 2/23/2016 Comment: i PLANS EXAMINER REVIEW COMPLETE William Durden 815/2015 8/31/2015 8131/2015 i Comment: REVISIONS INCOMPLETE William Durden 11/23/2016 i Comment: • SUBMIT THE PRODUCT APPROVALS, IN DUPLICATE OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH 11/23/2016 FLORIDA PRODUCT.APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.842 OF THE FLORIDA STATUTES. Comment: NOTE: IF SUBMITTING 2 COPIES OF PRODUCT APPROVAL'S (I.E. N.O.A. OR STATE OF FLORIDA APPROVAL) 11/23/2016 IN LUE OF THE PRODUCT APPROVAL AFFIDAVIT DOCUMENTS MUST BE HIGHLIGHTED OR MARKED IDENTIFYING THE OPENING OR CLADDING COMPONENTS, WITH FASTENERS AND DESIGN PRESSURES. 11/23/2018 Comment: PLEASE SUBMIT PRODUCT APPROVALS FOR THE SKY LIGHTS MEETING THE REQUIREMENTS OF SECTION 402.1.1 SUBSECTION B. Planning & Development Services Building & Code Regulation Division, 2300 Virginia Avenue Fort Pierce, FL: 34982 Phnnp-17721162.2172 Fax_f7721462-6443 Comment: 11/23/2016 Comment: 11/23/2016 11/23/2016 Comment: 11/23/2016 Comment: ZONING REVIEW Comment: REVIEW COMMENTS rage c - GLAZING AND THERMAL CHANGES. PLEASE FURNISH ENEGRY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 OF THE 2014 FLORIDA ENEGRY CODE FIFTH EDITION. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER - PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE FOR THE NEW ROOFING SYSTEMS. REVIEWED AND APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 O� THE FLORIDA ADMINISTRATIVE CODE • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE FOR THE NEW ROOFING SYSTEMS. PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE PLEASE SUBMIT DOCUMENTS FOR THE NEW ELEVATOR HOISTING SYSTEM. SEE SECTION 107 OF THEE 2014 FBC. COMPLETE Jeffrey Johnson 7/8/2015 3/212016 31212016