1506-0473 CONSTRUCTION PLAN PAGE 1-22
iid NOTES 1. ALL EXTERIOR DOORS AND WINDOWS SHALL BE INSTALLED PER MIAMI-DADE COUNTY NOTICE OF ACCEPTANCE OR FLORIDA PRODUCT APPROVAL. 2. GENERAL CONTRACTOR TO PROVIDE 5 SETS MINIMUM PRODUCT SUBMITTALS AND ONE SAMPLE OF EACH. 3. HARDWARE SHALL BE SUBMITTED TO OWNER FOR APPROVAL PRIOR TO ORDERING. 4. HARDWARE MANUFACTURER TO PROVIDE EMBOSSING TO IDENTIFY KEYS AT NO ADDITIONAL COST TO OWNER. 5. ALL HARDWARE TO COMPLY WITH STATE, LOCAL CODES AND REQUIREMENTS. 6. HARDWARE SUPPLIER TO REVIEW PLANS, SCHEDULE AND PROVIDE ANY ITEM REQUIRED TO COMPLETE THE SET; VERIFY ALL QUANTITIES AND DOOR SWINGS. 7. FINAL FINISH SELECETION BY OWNER AND ARCHITECT. 8. ALL EXTERIOR DOORS SHALL HAVE WEATHER STRIPING. 9. ALL WOOD DOORS TO BE STAINED TO MATCH EXISTING DOORS (TO REMAIN). CONTRACTOR TO SUBMIT COLOR SAMPLES TO OWNER FOR APPROVAL, PRIOR TO FINISHING OF CUSTOM DOORS. 10. COORDINATE WITH OWNER FOR REMOTE ACCESS LOCKING DOOR LOCATIONS AND VIDEO SURVEILLANCE REQUIREMENTS FOR ENTRY DOORS. FINISH FLOC FINISH FLOC FINISH CLEAR LOW-E CLEAR LOW-E CLEAR LOW-E GLAZING GLAZING GLAZING 10'-0" FINISH FLOOR WOOD CLAD BOARD & BATTON GARAGE DOOR 11 VARIES 10 VARIES I I EQ. EQ. 6'-0" T-0" T-0" 0D El El - ULI - - L3.0� ®0L ® ® c I.I L m®n ®mm Ej j � I L ®o_F1 M11E 0 L: L10 � �:®:12 R CUSTOM STAINED CUSTOM STAINED 21 CUSTOM STAINED 21 PANEL 21 PANEL DOOR PANEL DOUBLE DOOR DOUBLE POCKET DOORS 1 2 3 DASHED LINES INDICATE DOOR POCKET INSIDE OF WALL DOOR TYPES � 1 SCALE:1/4"=V-0" A-6.01 4'-0" VARIES l 2'-0" 2'-0" I I VARIES l WOOD CLAD / BOARD & GARAGE DOOR WOOD CLAD GARAGE DOOR CUSTOM ENTRY DOOR BATTON _// 12 BOARD & BATTON 13 ASSEMBLY OWNER SELECTED 1 4 SEE WINDOW TYPE "V" ON WINDOW TYPES SHEET A-6.03 CUSTOM INTERIOR DOOR SCREEN DOOR \- DECORATIVE, 1 5 1 6 PERFORATED METAL SCREEN ATTACHED TO 0 i a U N r� of < vi m m U Q W 0 O U a J ey LL N L C-' X y -- Z ci lLL z O om� -' o «' w x N � z w F- W U Z Lu 0 W w Z Z 00 (f)H Z 0 E Q z Q u d e a W J W U) W 0.' Q 0 Q 2 C] Z m Q W Of Z 0 0 0 0 DOOR o N O DOOR TYPES CONTINUED 1 z 6 zmm m°o SCALE: 1/4"=1'-0" A-6.01 FILE a a copf WINDOW SCHEDULE O QUANTITY ROUGH OPENING WINDOW TYPE FRAME GLAZING NOA No. or FPA No. DESIGN PRESSURE NOTES WIDTH HEIGHT A 5 T-0" 3'-2" SINGLE HUNG PAINTED ALUM. IMPACT, CLEAR FL # XXXX NOA # XX-XXXX.XX +XX.X / -XX.X PSF xxxxxxx . .............. W� �M MM0 zmz��_RM �� N m - I . . .... . C 2 5'-8" 31-21' SINGLE HUNG PAINTED ALUM. IMPACT, CLEAR OA R'R, 111"��11� i i I i i I i i I I I] i 111, i i i I i I i i i i i 11 i i i i I i i i 11,11, i 11, i i i i i i i i i i i i i i i i i i i i i i i i i i i I I I I I I I I I I "i .111 i i i i i i I i i I I I i I I I I I I i i E 1 T-O" 4-�8" CASEMENT PAINTED ALUM. IMPACT, CLEAR ..... . .. . . . ..... . . . . . ....... . ..... ...... ..... .. G 9 5'-0" 4'-8" CASEMENT FIXED PAINTED ALUM. IMPACT CLEAR 7 ....... ................... 1 3 T-4" 4'-8" CASEMENT FIXED PAINTED ALUM. IMPACT, CLEAR 10 Wo NMI% 1 Im RA L x4m R, 1 5.8" 4'-2" CASEMENT FIXED PAINTED ALUM. IMPACT, CLEAR CUSTOM STAINED GLASS INSERT 5 Jel e NUM 4 mum %=, ... . .... N 3 2'-6" 6-4- CASEMENT PAINTED ALUM. IMPACT, CLEAR ligg"immigi ligpit.1% * AmmiNvAr RMIRM . . . . . ..... . . �7 zz . ........ . .. . . . . . Q MIINP�E�T s 1 1 NE 8'-10" (2) 4'-2" 111146440115 6'-8" 6--2" CASEMENT FIXED gim 'T. N=Ma g�g MT. 1�211,m CASEMENT FIXED P1, T It '1%%%A%%J%% P_ml PAINTED ALUM. 7PAWN 119F 1111100.."mm PAINTED ALUM. 00"pi k ii, IMPACT CLEAR IMPACT, CLEAR pwo Pig . ..... :% MOM 1111. .11� .. 11101111111 .... M�M EN :1 RION BUTT GLAZED CORNER WINDOW 111111111115%01111 FROM 1E1 101101 U g� M W 2m 1 1 1HI 111111110 6-4- 8'-8" 61-811 FIXED TRANSOM In MwImmi, FIXED SIDELITE PAINTED ALUM. PAINTED ALUM. IMPACT, CLEAR IMPACT CLEAR 1. .. . ... . ... . 1 . .... . . . IP Y A 1 3'-0" 111P. M.11� 5-4- CASEMENT FIXED PAINTED ALUM. 2M019ii IMPACT ,CLEAR mmm% AA 1 V-6" V-13" FIXED GLASS PAINTED ALUM. IMPACT, CLEAR ..... IK .. . .. CC 1 2--6" T-10" FIXED GLASS PAINTED ALUM. IMPACT CLEAR EE 2 3--1" 3--1" FIXED GLASS PAINTED ALUM. A 11,1=M Al I IRA IMPACT, CLEAR IKAPArT rl PAP ii FIXED GLASS WINDOW WITH STAINED GLASS INSERT ..... . ...... WINDOW TYPE- G SCALE: 1/2" = V-0" m . 31-0" 01 6-0.1 2" 2" 2 -8' 2" 2"? �p, 2'L, 2'-0 4" v Iry 2" 2'-0 2" g � 15 aA EB C14 c"! CLEAR GLASS, CLEAR GLASS, DIVIDED LITES DIVIDED LITES 9!1 mEm C-4 cli 0 F_ B 0 z:) ALUMINUM ALUMINUM Of STILES AND STILES AND II-_ RAILS - BRONZE RAILS - BRONZE U) 0 in Of 0 U- FINISH FLOOR uj cn WINDOW TYPE- A WINDOW TYPE- B m SCALE: 1/2" = V-0" SCALE: 1/2" = V-0" Of Lu LL 51 -811 01 2-4- LID 211 � 214- 2'1,, 4" v liv- 2" -2-1 14 2-4- e 2"? c; c6 CV cli C) CLEAR GLASS, kv CLEAR GLASS, DIVIDED LITES DIVIDED LITES 0 04 ALUMINUM STILES AND RAILS - BRONZE ALUMINUM 9 STILES AND N RAILS - BRONZE WINDOW TYPE- C SCALE: 1/2" = V-0" T-0" WINDOW TYPE- D SCALE: 1/2" = V-0" 2"I_L" 2'�� 4",.t- 2)'-6" C14 NCLEAR GLASS, CLEAR GLASS, DIVIDED LITES DIVIDED LITES Ll iv E iv F O ALUMINUM O ALUMINUM 9 STILES AND 9 STILES AND RAILS - BRONZE N RAILS - BRONZE FINISH FLOOR WINDOW TYPE- E SCALE: 1/2" = V-0" 21-011 T-4" v 101-0.1 2" -2" 4'-6" 2'-_�, 4- 21' a; 2" 2- -2 1-8 L_ 4" _2". 2"� 2 2' _4,. V-4" 4' T-0' 112 ?,0 9 GLASS, N NCLEAR GLASS, NCLEAR GLASS, -EAR VIDED LITES DIVIDED LITES DIVIDED LITES 04 or cV N NN C? - . lr It zl)N ALUMINUM N O ALUMINUM -UMINUM FILES AND o STILES AND o STILES AND MLS - BRONZE 04 �IN RAILS - BRONZE N RAILS - BRONZE NN WINDOW TYPE- H NOT USED WINDOW TYPE- J WINDOW TYPE- K SCALE: 1/2" = V-0" SCALE: 1/2" = V-13" SCALE: 1/2" = V-0" WINDOW TYPE- F CLEAR GLASS, DIVIDED LITES wKi ALUMINUM STILES AND RAILS - BRONZE /DECORATIVE, STAINED/LEADED GLASS INSERT ON INTERIOR SIDE OF WINDOW FINISH FLOOR WINDOW TYPE- L SCALE: 1/2" = V-13" r, O u �4 C) W 0 u < ax 'm z 0 z 0 0 N 1- z w 2 = < fn z 0 cn z m: 0 Lu w Z Z 00 U) Z E 0 m z 0 NH % c' A E zim m W) 0 @ U) I I 2" 7-2" -2" 2„ 2'_0" 7,_On 211 2" 1'-4" 4" 2" 2" 2'-8" 4" Z' 1 -4' 2" 1110 .110 ef N CLEAR GLASS, - DIVIDED LITES — -. W �y CLEAR GLASS, _ iv DIVIDED LITES iv W 17 N / a0 IT ✓ _. 00 IT (O I 0'M M \ P O J N O O ALUMINUM ALUMINUM co o STILES AND q STILES AND iv RAILS - BRONZE RAILS - BRONZE WINDOW TYPE- M in �` F SCALE: 1/2" = V-0" CLEAR GLASS, DIVIDED LITES 2" ALUMINUM STILES AND RAILS - BRONZE N 2,_8" 2" WINDOW TYPE- N SCALE: 1/2" = 1'-0" 04 CLEAR GLASS, DIVIDED LITES I ALUMINUM STILES AND _ RAILS - BRONZE 0 N WINDOW TYPE- P SCALE: 1/2" = 1'-0" 1,_2„ 2„ 2 6 2„ 2„ . 2,_6„ 2„ 1 2 2„ N N c0 O � o JM M N L r S N 0 LEFT SIDE OF ASSEMBLY RIGHT SIDE OF ASSEMBLY in CORNER WINDOW UNIT " 2„ 4„ 2" 4,_s„ 2„ 4„ 2„ 1,-4„ 2„ Lie vv vie (V CLEAR GLASS, ` DIVIDED LITES lV CV V1 04 ® ALUMINUM STILES AND `D RAILS - BRONZE `y WINDOW TYPE- Q SCALE: 1/2" = 1'-0" — — 2" 1.... 2" WINDOW TYPE- R SCALE: 1/2" = 1'-0" FN .tI w §.-rig v.Ew Him Zm U) Z Of O LL- O7 F— W Lo P i M N co r 0 a U N m 'FITIFFIT-7- y 0 0 ev (n ) U a a H'I W o � N U a �a m N E- z U x 0 En z om� N W Q N 1 r Q N n t m W w Q 1 m N H W U Z W 0 07 W w o U Z E e O z i 45 m Q a Jy /n N - V^r ) P N ry 8 Nm� O " N Q o EE °� Z; m` Zry ' N N ❑ o �N N aa0 50 in 0 ih Ni 2" V-6" N N CLEAR GLASS, ` CLEAR GLASS, = DIVIDED LITES 'l DIVIDED LITES CP IT C9 N N N N ao .. Lo .._ in .. O fV� N O CZ ALUMINUM STILES AND STILES AND RAILS - BRONZE o RAILS - BRONZE r7 WINDOW TYPE- Y Om� mm SCALE: 1/2" = V-0" t3'-1" WINDOW TYPE- EE SCALE: 1/2" = V-0" WINDOW TYPE- Z SCALE: 1/2" = 1'-0" 1'-6" X fV FIXED CLEAR GLASS ALUMINUM STILES AND RAILS - BRONZE CV c N 00 2'-2" CLEAR GLASS, DIVIDED LITES ALUMINUM STILES AND RAILS - BRONZE FIXED CLEAR GLASS, DIVIDED LITES ALUMINUM STILES AND RAILS - BRONZE WINDOW TYPE- AA WINDOW TYPE- BB WINDOW TYPE- CC WINDOW TYPE- DD SCALE: 1/2" = 1'-0" SCALE: 1/2" = V-0" SCALE: 1/2" = V-0" SCALE: 1/2" = V-0" 3'-9" 6'-0" 2'-0" 2„ 1'-4y,, 2„4„2„ 1'-4%2„ 2„ Ao 1, 0„2„ 4„ 2„ Liv-2,�„ 2„ 4„ p1,_0„ 2" 2„ 1,_6„ 2„ d N N FIXED CLEAR _ - _ _ FIXED CLEAR GLASS, DIVIDED GLASS, DIVIDED FIXED CLEAR GLASS, LITES LITES DIVIDED LITES o I I L.--- --- STAINED WOOD N b - N CD FRAMES AND Lo I. MUNTINS - - — ALUMINUM I 1 ALUMINUM S TILES AND STILES AND RAILS -BRONZE RAILS - BRONZE fV CV FF WINDOW TYPE- FF SCALE: 1/2" = V-0" WINDOW TYPE- GG SCALE: 1/2" = 1'-0" WINDOW TYPE- HH SCALE: 1/2" = T-0" L� r U. z C c It C LL H LL cf. H r LL O. LC d C w 2 a ,a9 N z m d F-� 0 O � m m rn U K aLL WCD m 2 N z _ W O Om 3 Fz 0 z W a m ^ K co M N W U z W 0 W w 00 U) H z0 E oo z Q d a 0 LLI z F z O U 07 Lu a d O Z o = z_ 2 � ELECTRICAL SYMBOL LEGEND SPECIFICATIONS: Y U BASIC MATERIALS BASIC MATERIALS CONT. FIRE ALARM/DETECTION SYSTEM TELEPHONE/DATA SYSTEM I. THE TOTAL ELECTRICAL INSTALLATION MUST MEET THE REQUIREMENTS OF THE 2008 EDITION OF NFPA 70, THE NATIONAL ELECTRICAL CODE, NFPA 72 2002, THE WITH THESE PLANS THAT REQUIRE MAINTENANCE. AT A MINIMUM, THE MANUAL SHALL INCLUDE: o NATIONAL FIRE ALARM CODE, THE 2010 FLORIDA BUILDING CODE, AND THE 2010 A. EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT FLORIDA FIRE PREVENTION CODE. REQUIRING MAINTENANCE. SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION 2. ON ALL ELECTRICAL PLAN SHEETS, E.G. T-I", "E-2.1% ETC., THE TERM "CONTRACTOR" SHALL MEAN 'ELECTRICAL CONTRACTOR', SOMETIMES ALSO "E.C.". B. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF Sa SINGLE POLE SWITCH ® AUTOMATIC TRANSFER SWITCH MANUAL PULL STATION PHONE/DATA OUTLETS MOUNTED AT RECEPTACLE (SUBSCRIPT INDICATES ITEM CONTROLLED) -FUSED HEIGHT UNLESS OTHERWISE NOTED. C =ABOVE THE COUNTER 3. ABBREVIATED AS MATERIALS AND EQUIPMENT INSTALLED SHALL BE ENTIRELY NEW, UNLESS EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. S3 THREE-WAY SWITCH �. NON DISCONNECT SWITCH, AMP RATING / # OF POLES ® CEILING SMOKE DETECTOR, PHOTOELECTRIC M = NUMBER OF DATA PORTS, DEFAULT = I OTHERWISE NOTED, AND SHALL MEET U.L. REQUIREMENTS. S4 FOUR-WAY SWITCH NEMA I IF INDOORS NEMA 3R IF OUTDOORS TYPE UNLESS OTHERWISE NOTED N = NUMBER OF PHONE PORTS, DEFAULT = 1 4. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE C. NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. E = ELEVATOR WITH RECALL CONTACTS M DATA 8P8C ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. o Sp SINGLE POLE SWITCH WITH PILOT LIGHT FUSED DISCONNECT 30AR I = IONIZATION OUTLET, 5. CONTRACTOR TO INSTALL A COMPLETE ELECTRICAL SYSTEM FOR LIGHTING AND 37. WORKMANSHIP, MATERIALS AND APPARATUS UNDER THIS CONTRACT SHALL BE SWp SINGLE POLE SWITCH WITH WEATHERPROOF COVER [�j1 AR DENOTES AMP RATING OF SWITCH 20AF DUCT SMOKE DETECTOR POWER IN ACCORDANCE WITH THESE PLANS FROM THE POINT OF ATTACHMENT OF GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL AF DENOTES AMP FUSE SIZE 0 N PHONE OUTLET, RJII THE POWER COMPANY TO AND THROUGH THE MAIN DISTRIBUTION PANEL AND ACCEPTANCE BY THE OWNER. SWST SPRING WOUND WALL SWITCH TIMER (30 MIN.) MCP # DENOTES FUSE PER MANUFACTURER RECOMMENDATIONS R = RETURN BRANCH -CIRCUIT PANELS TO AND INCLUDING ALL OUTLETS, DEVICES AND 38. GREATER THAN 80% NONLINEAR LOADS: SHARED NEUTRALS AND GROUNDS ARE SK SINGLE POLE KEY SWITCH SIZE # OF POLES S = SUPPLY M L N COMBINED DATA/PHONE OUTLET, 8P8C/RJII 6. EQUIPMENT FURNISHED BY OTHERS ,AS MAY BE REQUIRED. CONTRACTOR SHALL MAKE EARLY CONTACT AND MAINTAIN DIRECT COMMUNICATION NOT PERMITTED FOR SINGLE PHASE CIRCUITS. 39. A. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE S3K THREE-WAY KEY SWITCH Ip 30/3 3R COMBINATION MAGNETIC MOTOR STARTER, SIZE 8 # OF POLES ® SUPERVISED CONTROL RELAY WITH THE SERVING ELECTRIC UTILITY TO ENSURE CORRECT INSTALLATION OF WITH NEC 110. S4K FOUR-WAY KEY SWITCH 0 3 POLE UNLESS OTHERWISE NOTED DUCT SMOKE REMOTE ALARM INDICATING LAMP, ® TELEPHONE OUTLET FLOOR MOUNTED CONDUITS PRIOR TO CONCRETE AND PAVEMENT INSTALLATIONS, TO ENSURE B. THE EXCLUSIVELY -DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL SL LIGHTED HANDLE SWITCH ENCLOSURE NEMA RATING. R W/ TEST SWITCH, WALL MOUNTED 72" AFF CORRECT INSTALLATION OF METERING FACILITIES, AND TO ENSURE THE TIMELY CEILING WITH A WIDTH AND DEPTH OF THE PANEL BOARD OR SWITCHBOARD MUST NEMA STARTER SIZE PROVISION OF ELECTRIC SERVICE. BE CLEAR OF ALL PIPING, DUCTS OR EQUIPMENT FOREIGN TO THE ELECTRICAL SLV $F LOW VOLTAGE SWITCH CEILING FAN/LIGHT CONTROL, DAN'S FAN CITY #423LW OR EQUAL - BRANCH CIRCUIT PANEL BOARD, UNDER 250 VOLTS, REMOTE INDICATING LAMP FIRE ALARM WITH TEST SWITCH TTB ® TELEPHONE/COMPUTER TERMINAL BOARD 7. CONTRACTOR TO COMPLETE ALL WORK INCIDENTAL TO MECHANICAL TRADES FOR A COMPLETE INSTALLATION, INCLUDING CONTROL WIRING, MOTOR STARTERS, EQUIPMENT OR ARCHITECTURAL APPURTENANCES IN ACCORDANCE WITH NEC 408. 40. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE -RESISTIVE WHITE COLOR SURFACE MOUNTED " WALL MOUNTED 72 AFF, SIMPLEX 4098-9842 OR EQUAL DISCONNECT SWITCHES AND EQUIPMENT GROUNDS. ASSEMBLIES, (CLASSIFIED AS FIRE/SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED SM MOTOR RATED SNAP SWITCH, IHP MIN., 20A, 120/277V --C BRANCH CIRCUIT PANEL BOARD, UNDER 250 VOLTS, C 8. CONTRACTOR TO MAKE NECESSARY PROVISIONS FOR THE INSTALLATION OF WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS o LEVITON 1121-2 OR EQUAL - FLUSH MOUNTED COMBINATION AUDIBLE/VISUAL TELEPHONE TERMINAL CABINET TELEPHONE, DATA, AND SMOKE/CO ALARM SYSTEMS INCLUDING RACEWAYS, SHALL BE MET PER FBC 302: SoMANUAL MOTOR STARTER WITH OVERLOAD HEATERS AND _ BRANCH CIRCUIT PANEL BOARD, OVER 250 VOLTS, XXCD NOTIFICATION DEVICE CD = CANDELA RATING, MINIMUM 75 CD PER T �\TELEPHONE CABINETS, PULL BOXES AND OUTLETS. SEE SHOP DRAWINGS FOR EACH SYSTEM FOR ADDITIONAL DETAILS AND INSTRUCTIONS. A. ALL ELECTRICAL BOXES SHALL BE METALLIC. PILOT LIGHT SURFACE MOUNTED FBC II-4.28.3(4) � SYSTEM RACEWAY 9. CONTRACTOR SHALL FURNISH AND INSTALL ALL FIXTURES COMPLETE AS LISTED IN o z SD DIMMER SWITCH (1500 WATTS UNLESS OTHERWISE INDICATED) _ BRANCH CIRCUIT PANEL BOARD, OVER 250 VOLTS, SS FIRE ALARM SPEAKER -CEILING MOUNTED THE LIGHTING FIXTURE SCHEDULE B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE. B. Fort Pierce _ FLUSH MOUNTED TELEVISION RACEWAY SYSTEM 10. PANELBOARDS, SWITCHBOARDS AND DISCONNECT SWITCHES SHALL HAVE COPPER OR Engineering, Inc. STD SINGLE POLE SWITCH - TIME DELAY FOR EXHAUST FAN/LIGHTS COPPER (NOMINAL 15% BY VOLUME) CLAD ALUMINUM BUS. C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES. BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN WALL. WALL MOUNTED SPEAKER WITH STROBE II. ALL PANELS, DISCONNECTS, TIME CLOCKS, AND CONTACTORS SHALL BE LABELED Dependable Mechanical, Electrical DUPLEX RECEPTACLE, 5-20R UNLESS OTHERWISE NOTED SHALL INCLUDE PHASE, NEUTRAL AND GROUND CONDUCTORS XXCD CD = CANDELA RATING WITH A PERMANENT ENGRAVED LABEL. IDENTIFICATION ON THE LABEL MUST D. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED &C.A. No. 28173gn SINGLE 5-20R RECEPTACLE, T DENOTES TWIST -LOCK ,,,--------,,,CONDUIT AS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED). ❑TV TELEVISION OUTLET FOR ANTENNA CONFORM TO THESE ELECTRICAL DRAWINGS. 1/8 INCH BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE � 12. TYPEWRITTEN CIRCUIT IDENTIFICATION SHALL BE INSTALLED IN ALL PANELBOARDS, OPENING. BRANCH CIRCUIT CONDUIT CONCEALED IN SLAB, ®S FIRE ALARM SPEAKER - WALL MOUNTED TV TELEVISION SIGNAL WALL OUTLET EACH BREAKER HAVING A DISTINCTIVE DESCRIPTION COMPLYING WITH NEC 408.4. SP SURGE PROTECTION TYPE (TVSS) DUPLEX RECEPTACLE UNDERGROUND OR UNDER FLOOR. --� ATV -ATV DISTRIBUTION SYSTEM RACEWAY 13. THE MAIN BREAKER OR FUSIBLE DISCONNECT SHALL BE A QUICK -MAKE, QUICK -BREAK, LOAD -BREAK DEVICE. E. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE --BRANCH CIRCUIT CONDUIT EXPOSED (D FIRE ALARM SPEAKER WITH STROBE - CEILING MOUNTED 14. CONDUIT FOR UNDERGROUND SHALL BE SCHEDULE 40 PVC UNLESS OTHERWISE COMPLETELY FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL). ® PEDESTAL MOUNTED RECEPTACLE iI- GROUND OR GROUND ROD AS NOTED CD = CANDELA RATING ® MAGNETIC LOCK SHOWN AND/OR REQUIRED BY CODE. ® FLOOR OUTLET BOX AND DUPLEX RECEPTACLE /J EM EMERGENCY BRANCH CONDUIT VISUAL SIGNALING UNIT, WALL MOUNTED CCTV CAMERA W/ CONDUIT TO VIDEO 15. Y " � " " � " R CONDUIT FOR ABOVE GRADE SHALL BE GRC , IMC SCH 80 PVC OR EMT . "LFNC" SHALL BE USED FOR CONNECTIONS TO AIR HANDLING UNITS, CONDENSING F. PROVIDE A WALL AROUND OUTLETS LARGER THAN I6 SQUARE INCHES. THE INTEGRITY OF THE WALL RATING SHALL BE MAINTAINED. 1 WITH APPROPRIATE FLANGE. (NO AUDIO DEVICE) JUNCTION BOX UNITS, WATER HEATERS AND OTHER EQUIPMENT. SPARE CONDUITS SHALL HAVE A FLOOR OUTLET BOX WITH DUPLEX RECEPTACLE UP CONDUIT TURNING UP © FIREMAN'S PHONE JACK PULL WIRE INSTALLED. G. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 ® AND ONE COMBINATION W/ VOICE/DATA OUTLET PTZ PAN/ TILT/ ZOOM CCTV CAMERA W/CONDUIT 16. CONDUCTORS SHALL BE THHN/THWN EXCEPT WHERE SPECIFIED OTHERWISE ON THE SQUARE INCHES PER 100 SQUARE FEET OF WALL AREA. OUTLET BOXES LOCATED - aDN CONDUIT TURNING DOWN SPRINKLER TAMPER TO VIDEO JUNCTION BOX - MOUNTED MIN 15' DRAWINGS. CONDUCTORS NO. 8 AWG AND LARGER SHALL BE JOINED BY AN ON OPPOSITE SIDES OF FIRE -RESISTIVE ASSEMBLIES ® FLOOR OUTLET BOX WITH TWO DUPLEX RECEPTACLES 0 SWITCH CONNECTION AFF OR o CEILING APPROVED PRESSURE CONNECTOR. CONNECTION TO GROUND CONDUCTORS NO.I/0 AND ONE COMBINATION W/ VOICE/DATA OUTLET ] CONDUIT STUB AWG AND LARGER SHALL BE CAST BY FUSIBLE METAL PROCESS. ALL CONDUCTORS H. SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. 315 South 7th Street © POKE THRU FS SPRINKLER WATER FLOW MUST BE INSTALLED IN CONDUIT, AS NM OR MC CABLE, OR LFNC. CONDUCTORS IN PANELS THEIR Fort Pierce, FL. 34950 CONDUIT CONTINUED SWITCH CONNECTION SYNCHRONOUS MASTER CLOCK SYSTEM FACTORY LABELS VISIBLE TO A PERSON IN THE I. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS. Phone: 772 672-4636 PP POWER POLE SINGLE POLE SWITCH/RECEPTACLE COMBINATION FLEXIBLE CONDUIT FP FIRE ALARM SYSTEM PRINTER 17. W RKINGSHALL S ACEHAVE CONDUCTORS MULTIWIRE CIRCUITS SHALL BE GROUPED IN AT LEAST ONE Fax:772 672-4637 S� EXISTING TO BE REMOVED LOCATION WITHIN THE PANELBOARD OR OTHER POINT OF ORIGIN BY WIRE TIES OR S DUPLEX RECEPTACLE WITH EACH HALF ON SEPARATE CIRCUIT ZONE ADDRESSABLE MODULE SYNCHRONOUS SYSTEM CLOCK SIMILAR MEANS. MULTIWIRE CIRCUIT DISCONNECTS SHALL BE PROVIDED WITH A (BREAKER SHALL BE TWO POLE WITH COMMON TRIP) EXISTING TO REMAIN MEANS TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT THE DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER - EXISTING AFFECTED BY THIS PROJECT ® ELECTROMAGNETIC DOOR HOLD OPEN DEVICE FATC MASTER CLOCK CONTROL PANEL 18. POINT WHERE THE BRANCH CIRCUIT ORIGINATES. NO CONDUCTORS SMALLER THAN 12 AWG SHALL BE USED FOR POWER AND DUPLEX TAMPER -RESISTANT RECEPTACLE. MOUNT - - - FUTURE ®H ELECTROMAGNETIC DOOR HOLD OPEN DEVICE CONNECTION TO CLOSURE/ HOLDER CL MASTER CLOCK SYSTEM CONDUIT AND WIRING 19. LIGHTING. ALL CONDUCTORS SHALL BE COPPER, UNLESS NOTED OTHERWISE. COLOR CODE FOR 120/240V le SYSTEM SHALL BE: BLACK, RED, WHITE, 8 GREEN. COVER PLATE WITH SPANNER HEAD SCREWS NEW 20. CONTRACTOR SHALL VERIFY WITH ARCHITECT FOR DETAILED DIMENSIONS AND DUPLEX RECEPTACLE WITH TOP HALF SWITCHED � ELECTROMAGNETIC DOOR HOLD OPEN DEVICE 21. LOCATIONS OF OUTLETS AND EQUIPMENT AND FOR ANY REVISIONS IN LAYOUT. H CONNECTION TO CLOSURE/ HOLDER INCLUDES DETECTOR DOORBELL SYSTEM MOUNT WALL SWITCHES 44" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON DRAWING. GANG SWITCHES WHEREVER POSSIBLE. ? GFI RECEPTACLE (EWC DENOTES ELECTRIC LIGHTING rn EWC WATER COOLER. COORDINATE WITH EWC CEILING HEAT DETECTOR 135 F UNLESS OTHERWISE 22. SWITCHES SHALL BE TOGGLE TYPE, 120 VOLT, 20A, RESIDENTIAL SPECIFICATION o v H > rm INSTALLER FOR MOUNTING HEIGHT) OH INDICATED. GRADE, UNLESS OTHERWISE NOTED. SWITCHES SHALL MATCH COVER PLATE IN J too I--o-� FLUORESCENT STRIP FIXTURE DOOR PUSH-BUTTON STATION COLOR. CLEAR, LIGHTED HANDLE SWITCHES SHALL BE INSTALLED WHERE SHOWN. x z WP GFI RECEPTACLE. WP DENOTES WEATHERPROOF COVER. FIXTURE A BEAM DETECTOR - TRANSMITTER WP =WEATHERPROOF 23. r" RECEPTACLES SHALL BE LOCATED 1� ABOVE FINISHED FLOOR TO CENTER LINE OF a a o FLUORESCENT FIXTURE DEVICE, UNLESS OTHERWISE NOTED. ABOVE -COUNTER RECEPTACLES SHALL BE Q J GFI RECEPTACLE MOUNTED ABOVE COUNTER DESIGNATION ® BEAM DETECTOR - RECEIVER DB DOORBELL CHIME (SELF CONTAINED) MOUNTED 6" ABOVE BACK SPLASH TO CENTERLINE OF DEVICE. PRIOR TO ROUGH -IN, O 3 CIRCUIT- -2 a -LOWER CASE LETTER INDICATES CONTROL CIRCUIT SWITCH LEG E.C. SHALL SCHEDULE A WALK THROUGH WITH THE OWNER TO VERIFY RECEPTACLE z z a TWO DUPLEX RECEPTACLES WITH COMMON COVER NUMBER ® FLUORESCENT FIXTURE FACP ca FIRE ALARM CONTROL PANEL DB DOORBELL SYSTEM CONDUIT AND WIRING 24. HEIGHTS AND LOCATIONS. COVER PLATES SHALL BE LIGHT ALMOND OR IVORY IN COLOR (PROVIDE SAMPLES w coW o � � Co TWO DUPLEX RECEPTACLES WITH COMMON COVER SHADING DENOTES EMERGENCY LIGHT FIXTURE. FATC OF EACH TO OWNER FOR SELECTION I PRIOR TO ORDERING), THERMOPLASTIC, UNLESS MOUNTED ABOVE COUNTER ® FLUORESCENT WRAP AROUND OR SURFACE MOUNTED FIXTURE. rat FIRE ALARM TERMINAL CABINET OTHERWISE NOTED. RECEPTACLES WITH THERMOPLASTIC COVER PLATES SHALL BE Z MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED DOWN, UNLESS OTHERWISE O ISOLATED GROUND DUPLEX RECEPTACLE, 4 FLUORESCENT WALL MOUNTED FIXTURE WITH WALL OUTLET BOX FAAP FIRE ALARM ANNUNCIATOR PANEL - FLUSH MOUNTED DOOR CONTROL SYSTEM NOTED. RECEPTACLES WITH METAL COVER PLATES SHALL BE MOUNTED SUCH THAT F IG (ORANGE DEVICE) $. THE GROUND PIN IS MOUNTED UP, UNLESS OTHERWISE NOTED. DUPLEX RECEPTACLE HID, INCANDESCENT OR FLUORESCENT WALL MOUNTED FIXTURE 25. ALL NEW 125V RECEPTACLES SHALL BE NEMA 5-20R AND SHALL BE UL LISTED Q OTE: N 0 HID, FLUORESCENT, OR INCANDESCENT FIXTURE �F� FIRE ALARM SYSTEM CONDUIT AND WIRING TAMPER -RESISTANT TYPE. COLOR SHALL BE WHITE. OUTDOOR RECEPTACLES TICK MARKS SHOWN ON ANY DEVICE REPRESENTS RECEPTACLE (RED DEVICE) TYPICAL (> FLUORESCENT, OR INCANDESCENT WALL WASHER. FIREMAN'S ELEVATOR WARNING LIGHT MOTION DETECTOR 360 26. SHALL BE WEATHER RESISTANT. ELECTRIC MOTORS SHALL COMPLY WITH THE ENERGY POLICY ACT OF 1992. WHERE ELECTRICAL ABBREVIATIONS W CONNECTED TO THE EMERGENCY CIRCUIT CR APPLICABLE PER FBC TABLE 505.7.5. Z O rn FOR ANY DEVICE IN LEGEND ® ACCENT FLOOD LIGHTING - AIMING AS INDICATED CARD READER 27. ALL DEVICES SHALL BE MOUNTED VERTICAL, UNLESS OTHERWISE NOTED. E.C.: ELECTRICAL CONTRACTOR NL: NIGHT LIGHT W rn © CLOCK RECEPTACLE EXIT LIGHT FIXTURE ❑K DIGITAL KEYPAD 28. WHEN AN 'IG" ISOLATED GROUND RECEPTACLE IS SPECIFIED ON THE PLANS, THE GFI: GROUND FAULT PROTECTION P: PANEL Q � o M a ® SPECIAL PURPOSE RECEPTACLE, RATING AS NOTED _ +� DIRECTION ARROWS AS SHOWN PAGING SYSTEM &BACKGROUND MUSIC 0 BALANCED MAGNETIC DOOR CONTACT RECEPTACLE GROUNDING TERMINAL SHALL BE BONDED TO GROUND BY AN UNBROKEN, INSULATED, EQUIPMENT GROUNDING CONDUCTOR FROM THE RECEPTACLE WP: WEATHER PROOF LION: UNLESS OTHERWISE NOTED W o a o (SHADED QUADRANT INDICATES FACES) OF FIXTURE) TO AND WITHIN THE ENCLOSURE IN WHICH THE GROUNDED SERVICE CONDUCTOR IS VP: VAPOR PROOF AFF: ABOVE FINISHED FLOOR IG: ISOLATED GROUND Q as 0r w o (� LIGHTING CONTROL TIME CLOCK � WALL MOUNTED EXIT LIGHT FIXTURE BONDED TO THE GROUNDING ELECTRODE CONDUCTOR. THIS INSULATED CONDUCTOR AFG: ABOVE FINISH GRADE M: MOTOR LOAD BFC: BELOW FINISHED CEILING z Z L)) w U_ o ® PHOTOCELL, MOUNTED ON ROOF FACING NORTH COMBINATION EXIT/EMERGENCY LIGHT FIXTURE Q LOUDSPEAKER/ TRANSFORMER/ BAFFLE/ INTERCOM SYSTEM SHALL HAVE A CONTINUOUS GREEN FINISH WITH ONE OR MORE YELLOW STRIPES. THE FRAME OF THE "IG' RECEPTACLE SHALL BE CONNECTED TO A SEPARATE SA: SMOKE/CO ALARM LOAD SN: SOLID NEUTRAL O > GN GROUND BAR D`❑ EXTERIOR LIGHT FIXTURE WITH ARMS AS SHOWN SUPPORT TRUSS. (CEILING MOUNTED) EQUIPMENT GROUNDING CONDUCTOR WITH NO YELLOW STRIPES. IN EXISTING L LIGHTING LOAD F: FAN LOAD w Z `�G U o- Ld v ON DRAWINGS W = WALL MOUNTED OCCUPANCIES WHERE FEEDERS FROM THE SERVICE EQUIPMENT TO PANELBOARDS R: RECEPTACLE LOAD O 0 Q o OfTo a ® PLUG-IN STRIP WITH RECEPTACLES, 18' O.C. UNLESS PB ELECTRICAL PULL BOX C MASTER STATION ARE NOT TO BE REPLACED, THE ISOLATED EQUIPMENT GROUNDING CONDUCTOR a OTHERWISE INDICATED S LOUDSPEAKER/ TRANSFORMER/ BAFFLE/ C =COUNTER SHALL BE TERMINATED ON THE EQUIPMENT GROUNDING TERMINAL IN THE TRACK WITH TRACK LIGHT FIXTURE (TRIANGLES ENCLOSURE FOR EXPOSED CEILING AREAS D =DESK ORIGINATING BRANCH CIRCUIT PANELBOARD. ELECTRICAL DRAWING INDEX ENGINEER SEAL ® UNDER GROUND CONCRETE ENCASED DUCTBANK INDICATE QUANTITY OF LIGHT FIXTURES) W = WALL MOUNTED W =WALL MOUNTED 29. CONTRACTOR SHALL CONNECT AIR CONDITIONERS, PUMPS, FANS AND OTHER �ue��t'rII� JUNCTION BOX ® BATTERY PACK WITH TWIN HEADS (CEILING MOUNT) �D BATTERY PACK WITH TWIN HEADS (WALL MOUNT) HORN/TRANSFORMER FOR HIGH NOISE AREAS H = HAND SET TYPE HF = HANDS FREE 30. EQUIPMENT. AFCI CIRCUIT BREAKERS SHALL BE INSTALLED IN ACCORDANCE WITH NEC 210.12. SHEET DESCRIPTION ISSUED �t�*`6N�( C. r'�'A q� •`GE�S'�fi% JUNCTION BOX- WALL MOUNTED II WP = WEATHER PROOF 31. AIR CONDITIONER BREAKER SHALL BE MARKED LISTED HACR TYPE AS REQUIRED+�� `o��` F "•, v JUNCTION BOX- FURNITURE SYSTEM FEED PAEC r� PAGING SYSTEM EQUIPMENT CABINET IC INTERCOM SYSTEM SPEAKER BY NEC 110.3(B). IF BREAKER IS NOT MARKED, THE OUTSIDE DISCONNECT SHALL BE CHANGED TO A FUSED DISCONNECT WITH RATING AS NOTED ON A/C EQUIPMENT. No 6158 MOTION/OCCUPANCY SENSOR SYSTEM E-I ELECTRICAL LEGEND, SPECIFICATIONS 8 ABBREVIATIONS YES - ■ CONDUIT SEAL -OFF FITTINGS PATC W =WALL MOUNTED 32. CONTRACTOR SHALL MAKE TESTS AND ADJUSTMENTS AS REQUIRED, UPON COMPLETION OF THE WORK AND BEFORE FINAL ACCEPTANCE BY THE OWNER. THE E-2.1 ELECTRICAL POWER/LIGHTING SYSTEMS DEMOLITION PLAN YES/9 .- tt ' 9 : STATE tU LCP SS SURGE SUPPRESSOR �3 o PAGING SYSTEM TERMINAL CABINET ICEC CONTRACTOR SHALL TEST THE COMPLETE ELECTRICAL SYSTEM IN THE PRESENCE E-2.2 ELECTRICAL POWER SYSTEMS IST FLOOR NEW WORK PLAN YES 0%OF : s ••T p;' < �. - - r� LIGHTING CONTROL PANEL o INTERCOM EQUIPMENT CABINET E OLOAD E-2.3 ELECTRICAL POWER SYSTEM 2ND FLOOR NEW WORK PLAN YES P. m06`Se�OR B3 = DISTRIBUTIONBOARDDEVICE,SEEFOR RATING = DR DOCTORS REGISTRY SYSTEM CONDUIT AND WIRING � S CO U G BALANCE, GROUNDS, ANDTOSURE SATISFACTORY AND A3 = PANEL BOARD DEVICE, MAX I25KA PER PHASE CONFORMANCE TO CONTRACT REQUIREMENTS. E-3.1 ELECTRICAL LIGHTING SYSTEM IST FLOOR NEW WORK PLAN YES ,too, fw%"% ST SHUNT -TRIP BUTTON - FLUSH MOUNTED UNLESS © PASSIVE INFRARED OCCUPANCY SENSOR C = CEILING MOUNT ICrCTTC INTERCOM TERMINAL CABINET 33. EQUIPMENT, LABOR AND MATERIAL REQUIRED FOR TESTING SHALL BE FURNISHED E-3.2 ELECTRICAL LIGHTING SYSTEMS 2ND FUR. NEW WORK PLAN YES Timothy C. Trewwyyn, PE OTHERWISE NOTED NEMA 3R FOR EXTERIOR LOCATIONS W =WALL MOUNT VC VOLUME CONTROL BY THE CONTRACTOR(S) AS PART OF THIS CONTRACT. E-4 ELECTRICAL RISER, DETAILS YES P.E. No. 61580 EDH-X 34. AFTER COMPLETION OF THE WORK, THE CONTRACTOR SHALL SECURE CERTIFICATES LE]-Av\l\ ELECTRIC DUCT HEATER U❑ ULTRASONIC OCCUPANCY SENSOR /� IC �\ INTERCOM SYSTEM CONDUIT AND WIRING OF FINAL INSPECTION AND APPROVAL FROM AUTHORITIES HAVING JURISDICTION E-5 ELECTRICAL SCHEDULES AND CALCULATIONS YES TWE s a � I" EM OWY FOR rW MO � P'"P""E "m a_w ff f JU P'� E"�"'E W, "`' 1°` (AHJ). 11EY RREPAAE0. REUSE OR IWRIMER RnIMtE a MOTOR CONNECTION. C = CEILING MOUNT W =WALL MOUNT SSEC r� SOUND SYSTEM EQUIPMENT CABINET 35. WITHIN 30 DAYS OF ELECTRICAL SYSTEM ACCEPTANCE BY THE AHJ, THE CONTRACTOR SHALL PROVIDE THE BUILDING OWNER WITH RECORD DRAWINGS OF TWMMKSE S A TAIIM'B'SM"� RDUT � , M TEN BE R� tom,TO TW M &L RWS KSEMI �" ® VARIABLE FREQUENCY DRIVE ❑D PASSIVE INFRARED /ULTRASONIC OCCUPANCY SENSOR SSTC THE ACTUAL INSTALLATION. THE RECORD DRAWINGS SHALL INCLUDE A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND SHEET TITLE ELECTRICAL FH_D_1 ELECTRIC HAND DRYER C = CEILING MOUNT W =WALL MOUNT C;NSOUND SYSTEM TERMINAL CABINET FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. IF DD DIRECT DIGITAL CONTROL PANEL P =WITH PHOTOCELL FOR NIGHT ONLY OPERATION PROVIDED WITH COMPLETE FIELD MARKUPS ON THESE PLAN SHEETS, THE ENGINEER SHALL SYMBOL LEGEND, SMS SINGLE POLE SWITCH - PASSIVE S MODIFY THESE PLAN SHEETS INTO SAID RECORD DRAWINGS AND PROVIDE A ❑T TRANSFORMER INFRARED SOUND SYSTEM CONDUIT AND WIRING COPY TO THE OWNER AND TO THE CONTRACTOR AND RETURN THE ORIGINAL FIELD GENERAL NOTES & OCCUPANCY SENSOR MARKUP TO THE CONTRACTOR. 36. WITHIN 30 DAYS OF ELECTRICAL SYSTEM ACCEPTANCE BY THE AHJ, THE ABBREVIATIONS ® OCCUPANCY SENSOR POWER SUPPLY CONTRACTOR SHALL PROVIDE THE BUILDING OWNER AN OPERATING AND ISSUE DATE: 06-12-2015 MAINTENANCE MANUAL FOR ALL ELECTRICAL SYSTEMS INSTALLED IN ACCORDANCE NOTE: DRAWN: TEC TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. WITH THE 2010 FLORIDA BUILDING CODE AND THE 2010 FLORIDA FIRE PREVENTION CODE. APPROVED: TCT DRAWING NUMBER E-1 SHEET I OF 8 15020-02 GENERAL DEMOLITION NOTES: COORDINATE SEQUENCING WITH OWNER AND OTHER CONTRACTORS. IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO PROTECT AND MAINTAIN THE INTEGRITY OF THE REMAINING DEVICES AND EQUIPMENT. 0 EXISTING SPA PUMP — LOCATED IN CRAWL. SPACE TO BE REMOVED AND RELOCATED. Ci J J � <E> i J J J E J 0 C Q EXISTING WATER PUMPS IN CRAWL SPACE CAI ♦�® f�I V` �~� 070, I I EXISTING PANEL LOCATED IN THE , CRAWL SPACE. SPA PANEL PUMP PANEL <E> <E> <E> �-- EXISTING SPA HEATER LOCATED IN CRAWL SPACE,I TO BE REMOVED AND/ RELOCATED. N.I.C. EXISTING CENTRAL — VACUUM SYSTEM TO REMAIN <E> < OUTSIDE <E> OVERHANG tK+ t: r f <R>� r_, \ <R> EXISTING GENERATOR, PAD, PANEL, UNISTRUT SUPPORTS, ETC. TO BE REMOVED. WIRE TO BE REMOVED TO POINT OF ORIGIN. EXPOSED CONDUITS TO BE REMOVED TO POINT OF ORIGIN, CONCEALED CONDUITS TO BE ABANDONED IN PLACE. <E>O 0 LANDSCAPE LIGHTING TIME CLOCK AND e CONTROLLER <> AO <R FPL METER AND SERMCE DISCONNECT SWITCH OR> /1, `"L SWITCH FOR HALL <> /. 7 UGHi1NG t/t,1t 1i (TER f * PANEL "PA"❑8 ® -,' WATER HEATER TO BE <R> /,0 RELOCATED 07 AUTOMATIC TRANSFER SWITCH TO BE REMOVED ELEC. EXIS7ING/DE>10 PLAN 1ST FLOOR SCALE 1/8" = 1'-0" ELEC_ EXISTNG/DEMO FLAN 2ND FLOOR ' SCALE 1/8" = I'-O" ELECTRICAL CONTRACTOR SHALL VISIT AND EXAMINE THE SITE PRIOR TO CONSTRUCTION TO ASCERTAIN THE EXISTING CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION. DISCONNECT, REMOVE OR RELOCATE ALL EXISTING ELECTRICAL MATERIAL AND EQUIPMENT THAT INTERFERES WITH NEW INSTALLATION. THIS INCLUDES BUT IS NOT LIMITED TO PANELS, LIGHTING FIXTURES, WIRING DEVICES, SIGNAL EQUIPMENT, EXHAUST FANS, BASEBOARD HEATERS, UNIT HEATERS, ETC. SEE MECHANICAL DRAWINGS FOR HEATERS, EXHAUST FANS, ETC. WHICH MUST BE DISCONNECTED BY THIS CONTRACTOR FOR REMOVAL OR ABANDONMENT BY MECHANICAL CONTRACTOR. ALL REMOVED EQUIPMENT SHALL BE DISPOSED OF BY THIS CONTRACTOR UNLESS DIRECTED TO DO OTHERWISE BY THE OWNER. WHERE WORK BY GENERAL CONTRACTOR (WALL REMOVAL, NEW OR RELOCATED WALL OPENINGS, ETC.) RESULTS IN THE REMOVAL, RELOCATION OR REFEEDING OF ELECTRICAL DEVICES OR LIGHTING FIXTURES. THE ELECTRICAL CONTRACTOR SHALL DISCONNECT AND RECONNECT ALL ACTIVE DEVICES REMAINING. ANY SUCH CONNECTIONS SHALL BE CONCEALED UNLESS LOCATED IN UNFINISHED AREAS. ANY EXISTING PANEL HOME RUNS, WHICH WILL REMAIN WITHIN THE AREA, MAY BE RETAINED AND USED AS PART OF THE NEW CIRCUITRY OR REMAIN AS SPARE EMPTY CONDUIT. SUCH EMPTY CONDUIT(S) SHALL BE MARKED AS TO PANEL AND END LOCATIONS. EXISTING OUTLET BOXES AND CONDUIT WHICH ARE LOCATED PROPERLY FOR NEW WORK MAY BE REUSED FOR NEW DEVICES AND WIRE. WHERE CONDUIT TO BE REMOVED STUBS THROUGH FLOORS, WALLS AND CEILINGS. SUCH CONDUIT SHALL BE REMOVED TO THE POINT WHERE THE FINISHED SURFACES CAN BE PATCHED ADEQUATELY SO THAT NO EVIDENCE OF THE FORMER INSTALLATION REMAINS. ALL CONDUIT AND WIRE REMOVED SHALL BE REMOVED TO THE SOURCE OF SUPPLY. ALL CUTTING, CORING AND PATCHING REQUIRED FOR ELECTRICAL WORK SHALL BE BY THE ELECTRICAL CONTRACTOR. INSTALL A BLANK COVER PLATE WHERE REQUIRED. • ANY ELECTRICAL ITEMS AND OR ELECTRICAL WORK THAT IS NOT COVERED UNDER "GENERAL DEMOLITION NOTES" SHALL FALL UNDER THE "OVERALL GENERAL DEMOLITION SPECIFICATIONSN COVERED IN THE ARCHITECTURAL CONTRACT DOCUMENTS. GENERAL DRAWING NOTE: THE CONTRACTOR SHALL VISIT AND CAREFULLY EXAMINE THOSE PORTIONS OF THE BUILDING AND SITE AFFECTED BY THIS WORK BEFORE SUBMITTING PROPOSAL SO AS TO BECOME FAMILIAR WITH EXISTING WORK. SUBMISSION OF PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. IT IS TO BE UNDERSTOOD THAT UNFORESEEN CONDITIONS PROBABLY EXIST AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON THESE DRAWINGS. COOPERATION WITH OTHER TRADES IN EQUIPMENT ROUTING AS DETERMINED DURING CONSTRUCTION AND AS DIRECTED BY THE ARCHITECT/ENGINEER MAY BE NECESSARY AND IT IS INTENDED THAT SUCH DEVIATIONS SHALL BE CONSIDERED AS PART OF THIS CONTRACT. THIS CONTRACTOR IS TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID AND INCLUDE ANY DEVIATIONS IN THE CONTRACT. ELECTkICAL DEMOLITION LEGEND SYMBOL DESCRIPTION <E> EXISTING TO REMAIN. <ER> EXISTING TO RELOCATED. <R> REMOVE AND TURN OVER TO OWNER. <ERP> EXISTING TO BE REPLACED. <ERC> EXISTING TO BE RECIRCUITED. <RE> RELOCATED EXISTING. ELECTRICAL DEMOLITION KEY NOTES: ❑I REMOVE ALL EXISTING ROUGHED IN ELECTRICAL ITEMS THAT ARE WITHIN THE DASHED LINE ENCLOSED AREA, INCLUDING LIGHTING, POWER AND SYSTEM DEVICES, EXCEPT WHERE NOTED WITH THE SYMBOL <E>, <ER>, <ERC>, OR <ERP>. ANY WIRING AND CONDUIT CAN BE REUSED AT THE CONTRACTORS DISCRETION. CONTRACTOR SHALL ALSO REMOVE ANY OTHER ELECTRICAL EQUIPMENT THAT MAY NOT BE SHOWN, BUT IS PART OF THE DEMOLITION SHOWN BY ATTACHED NOTES. CONTRACTOR SHALL COORDINATE WITH THE ARCHITECTURAL DEMOLITION PLANS AND ALSO FIELD VERIFY, PRIOR TO ANY REMOVAL. 02 ALL REMOVED EQUIPMENT SHALL BE DISPOSED OF BY THE CONTRACTOR UNLESS DIRECTED TO DO OTHERWISE BY THE OWNER. ALL DISPOSAL OF MATERIAL TO CONFORM TO EPA REGULATIONS. Q ALL EXISTING FLOOR BOXES (IF ANY) AND CONDUIT FOR POWER/TELEPHONE/DATA THAT ARE BEING REMOVED, SHALL BE ABANDONED IN PLACE. WIRE SHALL BE REMOVED AND PULL STRINGS INSTALLED WITH TAG, UNLESS NOTED "EXISTING TO REMAINN. ® ELECTRICAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE REPLACEMENT OF ANY DAMAGED EQUIPMENT AND OR MATERIALS NOT BEING REMOVED IN THIS DEMOLITION. Q EXISTING LIFT TO BE REMOVED. DISCONNECT AND REMOVE DISCONNECT SWITCH AND BRANCH CIRCUIT WIRING TO POINT OF ORIGIN. © EXISTING KITCHEN LIGHTING FIXTURES, RECEPTACLES, SWITCHES, ETC TO REMAIN UNLESS NOTED OTHERWISE. 7❑ WATER HEATER TO BE RELOCATED. EXISTING BRANCH CIRCUIT WIRING IS TO BE EXTENDED TO THE NEW LOCATION. REFER TO NEW WORK PLAN FOR THE NEW LOCATION. ® EXISTING TO BE REMOVED AND RELOCATED. REFER TO NEW WORK PLAN FOR THE NEW LOCATION. PROMDE WIRE/CONDUIT, JUNCTION BOXES REQUIRED FOR THE EXTENSION OF THE EXISTING BRANCH CIRCUITS TO THE NEW PANEL LOCATION. z 0 > w a 0 Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No.28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 Lo rn 1u o m J < U Go 6 Q 0 Ca w J U LL. O O F 3 w z • < w En a J U W N co O L1 W 4 0) rn W In Q o IT Q M w �? z o :50fF+�l o Q w m z Z o w o J � ~ W w d U 0 FCryll v O o [L Ir M Q CL a n a ENGINEER SEAL 110111111111"I ���y c. rR<A +4 6EIV8 F!L�� No 6158Q t� STATE OF . 4r P��;6` 40, R t Q R •',e O��e• f�r�fS/ONA� EN % Timothy C. Trewyn, PE P.E. No. 61580 TYLSE ➢OCLIENTS, NOG VIM THE COGEPTS NO W OESGNS PRESENM IEtSIII ARE INInGEO [ICY FM TIE SPECIFIC PIAE6RE NRI CLIENT 6 FORT PIERCE ENOPEERRG, INC. RR V)UN TIEY WERE FREPA REUSE W INPROER RF "E M Mm OICUE Ts wrwT WITTEN AUMIZRT3! NRR A ATR! RY FIRT PEACE DEINFERRG, INC. SYNC 1E WITIERIT LIABEITY TOME SANE. (WIZIN0©RIS, FRR PEACE nGREllUNG, PIG N RNMS RESERVN. SHEET TITLE ELECTRICAL DEMO PLAN 1 06-12-2015 1 DRAWN: TEC APPROVED: TCT I DRAWING NUMBER I FNW12-07 n 1 SHEET 2 OF 8 15020-02 a a a Y U (2)#12 B (D#12G. 3/4" C. 1,A IAh� )R UNIT WI MANUFACTI SYSTEMS PL,4N 1ST FLOCR SCALE 1/8" = 1'-0" (U#IOG. IN 3/4" C. SOUND ATTENUATED GENERATOR ENCLOSURE. 15OMPH NAND REFER TO FLOOR RATED. PLAN FOR — — r TION CONTINUA EXISTING PUMP AND WATER TANK. EXISTING WIRING TO BE I I MAINTAINED I APPROX. BATTERY CHARGER LOCATION 01 GENERATOR CONCRETE PAD PER MANUFACTURER'S SPECIFICATIONS APPROX. BREAKER LOCATION APPROX. GEN-SET CONTROLLER LOCATION --J GENERATOR MOUNTED IN THE ENCLOSURE SCALE:NONE ELECTRICAL DEMOLITION LEGEND SYMBOL DESCRIPTION <E> EXISTING TO REMAIN. <ER> EXISTING TO RELOCATED. <R> REMOVE AND TURN OVER TO OWNER. <ERP> EXISTING TO BE REPLACED. <ERC> EXISTING TO BE RECIRCUITED. <RE> RELOCATED EXISTING. LP GAS GENERATOR COORDINATE FINAL LOCATION WITH ARCHITECT PRIOR TO WP ROUGH -IN. E-3 RELOCATED IRRIGATION WELL. EXISTING BRANCH CIRCUIT WIRING IS TO INTERCEPTED AND EXTENDED TO THE NEW LOCATION OF THE WATER HEATER. ELECT. CONTR. IS TO FURNISH AND INSTALL WIRE/CONDUIT, DISCONNECTS, OUTLET BOXES, JUNCTION BOXES FOR THE EXTENSION AND RECONNECTION OF THE EXISTING BRANCH CIRCUIT WIRING TO THE IRRIGATION WELL. EXISTING UTILITY COMPANY PAD MOUNTED TRANSFORMER. FIELD VERIFY THE EXISTING LOCATION. SUB GRADE LP FUEL TANK. COORDINATE FINAL LOCATION PRIOR TO ROUGH -IN. ELECTRICAL KEY NOTES: QI CEILING MOUNTED DUPLEX RECEPTACLE FOR THE GARAGE DOOR OPENER. COORDINATE FINAL LOCATION IN THE FIELD PRIOR TO ROUGH -IN. ❑2 4"X4" JUNCTION BOX MOUNTED TO MACHINE ROOM WALL FOR 20A, 120V CIRCUIT (12/2+GRD) FOR THE ELEVATOR CAB LIGHTING AND BATTERY CHARGER. (MIN. 6" PIGTAIL) ❑3 4"X4" JUNCTION BOX MOUNTED IN THE MACHINE ROOM WALL FOR 30A, 230 IPH CIRCUIT (10/3+GRD-B,W,R,G) FOR MAIN ELEVATOR FEED. (MIN. 6' PIGTAIL) ® LIGHT FIXTURE, SWITCH AND GFCI RECEPTACLE TO BE LOCATED IN THE ELEVATOR SHAFT PER THE DIRECTION OF THE ELEVATOR INSTALLER ❑5 (D LIVE LAND IIASED PHONE LINE WITH PIG TAIL (MIN. 10'0") PER CODE. © VERIFY RECEPTACLE HEIGHT WITH OWNER PRIOR TO ROUGH -IN. 0 z 0 w La 0 0 z Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Port Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 J S n7 QQ F6VK Z � Q O 4i W J C) UOLj L 3 w F7 v Q J U M � In Z O F-1 Q Q Q W z 0) rn Q z U wz Q F- W Z O V] o ~ o C-) o a rn o 0 w o L f> E ~ a� O x 5 o of _j a d ti M I ENGINEER SEAL I 011111111111, IC. )-F-.# E No 6158Dj .. STATE OF . <C+? Ive�$�oNA"�1��`a Timothy C. Trewyn, PE P.E. No. 61580 THESE DUCLAENIS, &W V TIE CREEPTS ANB DR DESICM PRESENTED I[M]N PRE IRIENGEO REY M LE SPECIFIC PURRRSE MID CUENI 6 HIRT PIERCE ENGIIFFRiNfi, INC. FOt VMCN TIEY WERE PREPAMS. REUSE 0; IMPWPER REL]HlCE RI THESE [WnMMEJOS VITNWI WHO HJTIORZAn[N Hm AMPTATIM BY FDRT PIERCE ENGIIF➢tlNG, I SHALL BE VITINI LIABILITY W HE SHE CWYRRM �RNIS, F[Ri PIERCE ENGINEERING, INC. H1 RIGHTS RESERVER I SHEET TITLE I ELECTRICAL POWER SYSTEMS PLAN ISSUE DATE: 06-12-2015 I DRAWN: TEC APPROVED: TCT I DRAWING NUMBER I SHEET 3 OFI SHEET 3 OF 88 15021 a a a Y U SYSTEMS FLAN 2ND FLOOD' " SCALE 1/8" = 1`0" I I I I I F ELECTRICAL DEMOLITION LEGEND SYMBOL DESCRIPTION <E> EXISTING TO REMAIN. <ER> EXISTING TO BE RELOCATED. <R> REMOVE AND TURN OVER TO OWNER. <ERP> EXISTING TO BE REPLACED. <ERC> EXISTING TO BE RECIRCUITED. <RE> RELOCATED EXISTING ELECTRICAL KEY NOTES: QI EXISTING KITCHEN LIGHTING FIXTURES, RECEPTACLES, SWITCHES, ETC. TO REMAIN UNLESS NOTED OTHERWISE ❑2 VERIFY RECEPTACLE HI IGHT WITH OWNER PRIOR TO ROUGH -IN. C c Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 Lo rn a J t7 U to o Ca W J LL F a LJ F- Z CC w n a J i) U M es to z 0 F--I Q Q w z 0) m w o a a Q z U W Wzo z O U 0 J H U o 0' W o w d U _D O W fl� n Q d ti a rn OL I ENGINEER SEAL I ,NY C r7-"d'f,' E IV EIZ.L �i � ^ No 61580 s a ST/A7T'/P'I�° OF :*U11 �sOT ��< n ,� I �7 p;•'�T� `ems Timothy C. Trewyn, PE P.E. No. 61580 RESE IDICIM[N1S, N V TIE EOLFPTS W M RESIW PCESENTm IE NE PIIEtmEP OLY M uE SPECIFSc PURPRSE W CLSNT ❑ W PIERCE MWENW, INC. FM VWCH TIV VETS PREPM RLR6E IN �R RELP a TIE.CE ROYIFNTS VnINT VRITTEN MITI ATIM " nm Auffi W FOR PTFPCE ENOI UA PIG SHRLL K VnIW( LIMLITY n DiE SNE. CwYRIGnom5, FOR PIERCE EN6PEF X, M N OWS RESERVER I SHEET TITLE I ELECTRICAL POWER SYSTEMS PLAN ISSUE DATE: 06-12-2015 I DRAWN: TEC APPROVED: TCT I DRAWING NUMBER I IIIII�IIh� ��i�� SHEET 4 OF 8 15020-02 LIGHTING FIXTURE SCHEDULE MARK MANUFACTURER - PART NUMBER LAMPS VOLTS MOUNTING DESCRIPTION REMARKS NOI TYPE WATTS PROGRESS - P8075-28 I INC 75 120 CEILING 6' RECESSED VERTICAL, INSULATED CEILING RATED A AIR- E D DOWNLQHT WITH WHITE REFLECT913 B C PROGRESS - P831-AT-P8041-28 I PAR20 50 120 CEILING 4' RECESSED VERTICAL, INSULATED CEILING RATED AIR -SEALED DOWNLIGHT WITH WHITE BAFFLE D PROGRESS - P821-AT-P8079-28 I PAR30 75 120 CEILING RECESSED ADJUSTABLE EYEBALL FIXTURE WHITE BAFFLE AND TRIM E LEVITON 9726-C I INC 60 120 CEILING/WALL MEDIUM BASE ONE-PIECE PORCELAIN OUTLET BOX RECEPTACLE WITH GROUNDING MOUNT, PULL -CHAIN, WITH 15A RECEPTACLE FOR USE IN ATTIC F PROGRESS - P821-AT-P8060-28 I INC 40 120 CEILING 6' SHOWER FIXTURE, WET LOCATION LABEL, WHITE TRIM ABOLITE LENS G PROGRESS - P821-AT-P8062-28 I INC 40 120 CEILING 6' DOWNLIGHT WITH LENS, WHITE TRIM. H PROGRESS - P7263-30EB 2 T8 32 120 CEILING I X 4 SURFACE MOUNT FLUORESCENT FIXTURE, WHITE ACRYLIC LENS J PENDANT FIXTURE -SELECTED BY OTHERS - - 60 120 CEILING K WALKWAY FIXTURE -SELECTED BY OTHERS - - 100 120 CEILING L KITCHEN PENDANT FIXTURE - SELECTED BY OTHERS - - 100 120 CEILING M EXTERIOR WALL SCONCSE - SELECTED BY OTHERS - - 150 120 CEILING N PROGRESS - P7262-30EB 2 FBT8 32 120 CEILING 2' X 2' FLUORESCENT FIXTURE, ACRYLIC DIFFUSER WHITE FINISH, SURFACE MOUNTED P PROGRESS - P7183-30EB 2 TS 20 120 CEILING 8' X 2' FLUORESCENT WRAP FIXTURE, ACRYLIC DIFFUSER, WHITE FINISH, SURFACE MOUNTED R WALL SCONCE - SELECTED BY OTHERS I - - 1 150 120 WALL T PROGRESS - P7018-30EBS I I T8 1 15 120 SURFACE 18' UNDERCABINET FIXTURE WHITE FINISH GENERAL LIGHTING FIXTURE SCHEDULE NOTES: I. VERIFY TYPE OF CEILING FOR EACH FIXTURE WITH ARCHITECTURAL REFLECTED CEILING PLANS AND PROVIDE FIXTURE TRIM AS REQUIRED. 2. VERIFY VOLTAGES PRIOR TO BID AND INSTALLATION OF FIXTURES. 3. PROPOSED ALTERNATE LIGHTING BIDS MUST INCLUDE THE FOLLOWING: A. COST SAVINGS TO OWNER. B. PHOTOMETRIC LAYOUT OF PROPOSED ALTERNATE LIGHTING FIXTURES. C. ABOVE INFORMATION MUST BE SUPPLIED TO THE ENGINEER (3) DAYS PRIOR TO BID. 4. ALL COMPACT FLUORESCENT DOWNLIGHTS SHALL USE ELECTRONIC BALLASTS, UNLESS OTHERWISE NOTED. 5. PROVIDE APPROVED FIRE RATED ENCLOSURES FOR ALL LIGHT FIXTURES LOCATED IN FIRE RATED CEILINGS. 6. FIXTURES IN AREAS WITHOUT CEILINGS OR IN MECHANICAL AND ELECTRICAL ROOMS SHALL BE MOUNTED WITH I 1/2"M 1/2' KINDORF CHANNEL SUPPORT SUSPENDED FROM ROOF STRUCTURE WITH THREADED RODS. FIXTURES SHALL BE MOUNTED 10'-O'A.F.F. UNLESS OTHERWISE NOTED. 7. ALL ACRYLIC LENSED FIXTURES SHALL HAVE A MINIMUM LENS THICKNESS OF .125 INCHES. „LIGHTING SYSTEMS FL/4N IST fLCCR SCALE 1/8" = 1'-0" ELECTRICAL KEY NOTES: I❑ EXISTING KITCHEN LIGHTING FIXTURES, RECEPTACLES, SWITCHES, ETC. TO REMAIN UNLESS NOTED OTHERWISE ❑2 4'X4' JUNCTION BOX MOUNTED TO MACHINE ROOM WALL FOR 20A, 120V CIRCUIT (12/2+GRD) FOR THE ELEVATOR CAB LIGHTING AND BATTERY CHARGER. (MIN. 6' PIGTAIL) 0 4'X4' JUNCTION BOX MOUNTED IN THE MACHINE ROOM WALL FOR 30A, 230 IPH CIRCUIT (10/3+GRD-B,W,R,G) FOR MAIN ELEVATOR FEED. (MIN. 6' PIGTAIL) ® LIGHT FIXTURE, SWITCH AND GFCI RECEPTACLE TO BE LOCATED IN THE ELEVATOR SHAFT PER THE DIRECTION OF THE ELEVATOR INSTALLER ❑5 (U LIVE LAND BASED PHONE LINE WITH PIG TAIL (MIN. 10'00) PER CODE. © INSTALL NIW DUAL FLOOD OUTDOOR FIXTURE WITH MOTION SENSOR. AIM FLOODS AND ADJUST OFI'ECTOR PER OWNER DIRECTION. Al al Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 w m U 6 O It J m U to C Q Ca W O O O u 3 w W wzw v a J a O H U W N (n z C Q w z w Q o� M W H Z O Q o Q - 0 w o z z w 0 C o g U Cl) F m ~ W U d U O p ran a a ro 0- ENGINEER SEAL C No 615 �2 �'.• STATE OF O�. e 0 R Timothy C. Trewyn, PE P.E. No. 61580 I SHEET TITLE I ELECTRICAL LIGHTING SYSTEMS PLAN ISSUE DATE: 06-12-2015 I DRAWN: TCT APPROVED: TCT SHEET 5 OF 8 15020-02 LIGH7NG SYSTEMS NOTES I. SEE LIGHTING POWER DENSITY CALCULATIONS ON THIS SHEET. 2. FBC 303.2.3 RECESSED FIXTURES ARE AIR SEALED WITH A GASKET OR CAULK AND RATED FOR INSULATED CEILINGS PER ASTM E 283. OR AFFECTED AREA/OPAQUE INSULATED ARE <= 1% OR ROOF, WALL, OR FLOOR COVERED WITH INSULATION TO FULL DEPTH REQUIRED, REDUCED INSULATION EFFECTS INCLUDED IN ENERGY CALCULATIONS. 3. AT LEAST 50 PERCENT OF PERMANENTLY INSTALLED LIGHTING FIXTURES ARE SPECIFIED WITH HIGH EFFICACY LAMPS PER FBC 404.1. 4. CLASSROOM AND MEETING ROOM LIGHTING CONTROLS SHALL TURN OFF LIGHTING WITHIN 30 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE UNLESS MULTI -SCENE CONTROL USED. 5. HOTEL, MOTEL SLEEPING ROOMS SHALL HAVE MASTER SWITCH NEAR ENTRY CONTROLLING ALL PERMANENT LIGHT FIXTURES AND SWITCHED RECEPTACLES EXCEPT BATHROOM. 6. LC -I SHALL BE AN ASTRONOMIC TIME SWITCH, WITH TWO SETS OF SIMULTANEOUSLY CONTROLLED CONTACTS FOR 240V OPERATION, AND SHALL HAVE MINIMUM 10-HOUR BATTERY BACKUP. LIGHTING FIXTURE SCHEDULE MARK MANUFACTURER - PART NUMBER LAMPS VOLTS MOUNTING DESCRIPTION REMARKS NO TYPE WATTS A PROGRESS - P8075-28 I INC 75 120 CEILING 6' RECESSED VERTICAh INSULATED CEILING RATED AIR -SEALED DO I I ITE REFLECTOR 13 C PROGRESS - P831-AT-P8041-28 I PAR20 50 120 CEILING 4' RECESSED VERTICAL, INSULATED CEILING RATED AIR -SEALED DOWNLIGHT WITH WHITE BAFFLE D PROGRESS - P821-AT-P8079-28 I PAR30 75 120 CEILING RECESSED ADJUSTABLE EYEBALL FIXTURE WHITE BAFFLE AND TRIM E LEVITON 9726-C I INC 60 120 CEILING/WALL MEDIUM BASE ONE-PIECE PORCELAIN OUTLET BOX RECEPTACLE WITH GROUNDING MOUNT, PULL -CHAIN, WITH 15A RECEPTACLE FOR USE IN ATTIC F PROGRESS - P821-AT-P8060-28 I INC 40 120 CEILING 6' SHOWER FIXTURE, WET LOCATION LABEL, WHITE TRIM ABOLITE LENS G PROGRESS - P821-AT-P8062-28 I INC 40 120 CEILING 6' DOWNLIGHT WITH LENS, WHITE TRIM. H PROGRESS - P7263-30EB 2 T8 32 120 CEILING I X 4 SURFACE MOUNT FLUORESCENT FIXTURE, WHITE ACRYLIC LENS J PENDANT FIXTURE -SELECTED BY OTHERS - - 60 120 CEILING K WALKWAY FIXTURE -SELECTED BY OTHERS - - 100 120 CEILING L KITCHEN PENDANT FIXTURE - SELECTED BY OTHERS - - 100 120 CEILING M EXTERIOR WALL SCONCSE - SELECTED BY OTHERS - - 150 120 CEILING N PROGRESS - P7262-30EB 2 FBT8 32 120 CEILING 2' X 2' FLUORESCENT FIXTURE, ACRYLIC DIFFUSER WHITE FINISH, SURFACE MOUNTED P PROGRESS - P7183-30EB 2 T8 20 120 CEILING 8" X 2' FLUORESCENT WRAP FIXTURE, ACRYLIC DIFFUSER, WHITE FINISH, SURFACE MOUNTED R WALL SCONCE - SELECTED BY OTHERS - - 150 120 WALL T PROGRESS - P7018-30EBS I T8 15 120 SURFACE 18" UNDERCABINET FIXTURE I 1 1 WHITE FINISH GENERAL LIGHTING FIXTURE SCHEDULE NOTES: I. VERIFY TYPE OF CEILING FOR EACH FIXTURE WITH ARCHITECTURAL REFLECTED CEILING PLANS AND PROVIDE FIXTURE TRIM AS REQUIRED. 2. VERIFY VOLTAGES PRIOR TO BID AND INSTALLATION OF FIXTURES. 3. PROPOSED ALTERNATE LIGHTING BIDS MUST INCLUDE THE FOLLOWING: A. COST SAVINGS TO OWNER. B. PHOTOMETRIC LAYOUT OF PROPOSED ALTERNATE LIGHTING FIXTURES. C. ABOVE INFORMATION MUST BE SUPPLIED TO THE ENGINEER (3) DAYS PRIOR TO BID. 4. ALL COMPACT FLUORESCENT DOWNLIGHTS SHALL USE ELECTRONIC BALLASTS, UNLESS OTHERWISE NOTED. 5. PROVIDE APPROVED FIRE RATED ENCLOSURES FOR ALL LIGHT FIXTURES LOCATED IN FIRE RATED CEILINGS. 6. FIXTURES IN AREAS WITHOUT CEILINGS OR IN MECHANICAL AND ELECTRICAL ROOMS SHALL BE MOUNTED WITH I I/2'xl 1/2' KINDORF CHANNEL SUPPORT SUSPENDED FROM ROOF STRUCTURE WITH THREADED RODS. FIXTURES SHALL BE MOUNTED 10'-0"A.F.F. UNLESS OTHERWISE NOTED. 7. ALL ACRYLIC LENSED FIXTURES SHALL HAVE A MINIMUM LENS THICKNESS OF .125 INCHES. "LIC HTING SYSTEMS FLAIL 2ND FLOOD` SCALE 1/8,, = 1'—O" t t t t i t t t 1 t� r t t TUBE TYPE E NNTED IN THE ATTIC JACENT TO ATTIC CESS ELECTRICAL KEY NOTES: IQ INSTALL NEW DUAL FLOOD OUTDOOR FIXTURE WITH MOTION SENSOR. AIM FLOODS AND ADJUST DETECTOR PER OWNER DIRECTION. ❑2 GARDCO 943EMC D/C 26QF RGD 120 BRP EMERGENCY STEP LIGHT OR SIMILAR. MATCH SELECTED FIXTURE TO AVAILABLI STRUCTURE FOR MOUNTING WITH TOP OF LENS EVEN WITH TOP OF EACH FLIGHT OF STAIRS. Y U w 0 w w a a Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design CA. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 w H rn �U p rn J M to aQ Q a O 0 w J O UO L 3 UJ Z W Jn a J 7 U Pa ON to O 1--I F"J F-y Q Q Q W zJn W m w z W Q z O Z z o � 0 J o o o Lu a to to a 0 � F Y O 0 of M a a M a I ENGINEER SEAL I ``%%tiluu111aro�� �, ��..' C NO 6158� ��2 �. STATE OF T �fn5 �ORtOP' *,P;.,ONAL Timothy C. Trewyn, PE P.E. No. 61580 I SHEET TITLE I ELECTRICAL LIGHTING SYSTEMS PLAN ISSUE DATE: 06-12-2015 I DRAWN: TCT APPROVED: TCT I SHEET 6 OF 8 1 15020-02 NOTE: CONTACT ELECTRICAL ENGINEER AT LEAST 24 HOURS IN ADVANCE TO ARRANGE FOR CONDUIT INSPECTION PRIOR TO BACKFILL. SPOT FILLING TO PREVENT FLOATING IS ACCEPTABLE. A UTILITY SERVICE FEEDER TRENCHING DETAIL SCALE= METRAFLEX MI-SMB - TYPE OR EQUIVALENT SPRING MOUNT. (TYPICAL) #4 BARS o18I1O.C.—'v EACH WAY COMPACTED SUB -GRADE TO 98% OF ASHTO T-180 TO EXTEND UP TO 5' FROM EDGE OF FOUNDATION. GENERATOR AND ENCLOSURE I E I GENERATOR PAD DETAIL LOAD MANAGEMENT CONTROL CABINET RELAY LOGIC ALL CONDUCTORS #M SI TYPE ON IOA C.B. OR FUSED AT B AMPS MOUNT ALL DEVICES SHOWN IN A SINGLE CABINET IDA ATS T TERMINAL TI ATS T TERMINAL T2 ATS E TERMM ATS NEUTRAL TERMINAL NOTE: CONTACT ELECTRICAL ENGINEER AT LEAST 24 HOURS IN ADVANCE TO ARRANGE FOR CONDUIT INSPECTION PRIOR TO BACKFILL. SPOT FILLING TO PREVENT FLOATING IS ACCEPTABLE. 101j B I CONDUCTOR TRENCHING DETAIL POURED IN PLACE 3000PS1 CONCRETE. USE VIBRATOR TO FILL ALL VOIDS IN FORM. SEE MANUFACTURER SPECIFICATION FOR ANY OTHER CONCRETE REQUIREMENTS. 1LBOND GROUND ROD TO REBAR CAGE USING #4 SOFT DRAWN SOLID BARE COPPER AND MECHANICAL GROUND ROD CLAMPS. SUSSMAN TERMINAL BOARD LEGEND ALL CONTACTS SHOWN WITH TRANSFER SWITCH IN UTILITY POSITION, FREQUENCY NORMAL. 2 - TIMER RELAY 81 - UNDERFREQUENCY RELAY SCALE = SO D SO D SUSSMAN ZELIO RM35M]FM ZEUO RERRBMU TERMINAL BOARD UNDERFREOUENCY RELAY. SET THRESHOLD TO 56HL 5 SEC. DELAY. GENERATOR PROTECTION SETTING IS 56 HZ, 10 SEC. DELAY PER PAGE 19 OF SUBMITTAL F OPTIONAL SELF-CONTAINED LOAD SHED MODULE FUNCTION 'B' TIMER SET TO INSTANT CLOSE ON INPUT TO A THEN 60 MIN. INTERVAL ON 18, THEN TRANSFER TO 16 AND RESET TIMER GE CONTACTOR CRI60MC51037 TO PANEL 'LM' LI L2 N TI T2 N TO IOOA CB IN MDP FINISH GRADE ROCK GROUND WIRE AS REQUIRED by aLt(N 19 C PULL -BOX SECTION 1 # 3/0 GROUND CONDUCTOR -EXIST. CUTOVER TO NEW SERVICE DISCONNECT METAL PIPE - EXIST. METAL STRUCTURAL MEMBER -EXIST. 20 FT CONCRETE ENCASED I/O CU ELECTRODE -EXIST. EXIST.-5/8'z8' CU CLAD STEEL GROUND ROD MAIN DISTRIBUTION PANEL 'MDP 120/240V IPH 3W - ISM #6 (1225A 2P (I 175A 2P FIBERGLASS COVER. LABEL 'ELECTRIC' MIN. 12" RADIUS 200A 2P NEW ANEW (3) 0/0 CUB (3) 03/0 DU a (D #6 CU G.C. 0) 06 CU B.C. IN 2'C. IN 24C. P EL A� P'PEL EXTENDED NEW (3) 0/0 GU B (3) #2/0 CU e 0) #6 CU G.C. 0) f6 CU G.C. IN VC. IN M. NEW (3) #1 CU B (1) #6 CU G. IN 2•C. G ELECTRICAL RISER DIAGRAM EWH FIBERGLASS BODY CONDUITS (TYP.) ASS COVER. IDUIT TO BE WITH FOAM. ;ACE PG 8) BRASS 'L' BOLT. NOTES: I. FIBERGLASS JUNCTION BOX WITH SCREW DOWN COVER. SIZE AS REQUIRED. 2. SPLICES SHALL BE MADE WITH SPLIT BOLT CONNECTORS. CONNECTOR SHALL BE SEALED IN SILICONE GEL THAT WILL BE CONTAINED IN A CLOSURE AROUND THE SPLIT BOLT TO PROVIDE A WATERPROOF CONNECTION. THIS CLOSURE SHALL BE UV RESISTANT, IMPACT RESISTANT AND ABRASION RESISTANT. D I PULL -BOX DETAIL NEW (2) 2 1/2' C WITH (3) 350 MCM IN EACH 250A 2P (T 60A 2P MIN. (2) I 2P SPACES MIN 250A LOAD SHED ATS N L 4-00 LS T E (3) #250 MCM 5 (3) #6 CU G D f4G. 11) #D CU G.C. IN 2 I/2'C. IN PC. PANEL 'PUMP EXIST. -PER ATS MFR. HVAC-2 HVAC-4 INSTALL NEW 600A METER ENCLOSURE Fo 600A 60A 2P ( 30A 2P ES)#6 CU8 �bl }B CUB 0) #IO CU G.C. 0) #IO CU G.C. IN 10C. IN I'C. NOTE OIIORDMATE PROONIEIYEN( OF MYS WITH SEPARATE BP/M CIRCUIT TFINIMATI0116 FOR FAN MOTOR AND HEATER CIRCUITS NEW UNDERGROUND SERVICE LATERAL TO FPL 120/240V IPH 3W TRANSFORMER NEW 0) #2/0 CU e O) 06 CU G.C. IN 2'C. GENERATOR 36KW 120/240V IPH 175A METAL PIPE ICI Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 U Ci F J M mo C4 z a Ca W o J C)0 u- z a U� w z Tn a J � U N N U) z On Q Q w z W °' IT Q M LLI z � 0 2 W C' � E Q zz z U u o w 0 � O J LL 1 z w 0- O O o _j rro a d ti t1 ro CC ENGINEER SEAL JNY C Y fT9r�,'® Na 61525 STATE OF CC/,` dNA® Timothy C. Trewyn, PE P.E. No. 61580 THESE DOF.LIENTS, AL346 VIIH THE UNCEPTS ANO M DESIftllS PRESENTED IEREPI AY INTENDED RLY FOR THE SPECEIC PLRP6SE MID nJN31T 6 FORT PERtt ENGDFERING, X. FOR wall THEY VERE PREPARED RIUSE OR IMPROPER fEl1AREE IN THEY OOCLAENTS VITHOUO VRMSN MRINpATSN AND ADAPTAID! V FORT RHINE ENO� W. S H VITHOUT LIABILITY TO THIS SNE COPYRIGHT CM5, FORT PIERCE ENOINEERUG, V ALL RIGHTS RESERVED, SHEET TITLE ELECTRICAL RISER & DETAILS —#2 G.E.C. ISSUE DATE: 06-12-2015 DRAWN: TEC/TCT METAL STRUCTURAL MEMBER. 20 FT CONCRETE APPROVED: BID SET ENCASED 1/0 CU DRAWING NUMBER ELECTRODE 5/8N8' CU CLAD FFc STEEL GROUND ROD Illy o 4 SHEET 7 OF 8 15020-02 PANEL: „E„ VOLTAGE: 120/240V 1PH 3W BUS/BREAKER AIC RATING: 22KA/10KA RATING: 250A LOCATION: MECH/ELECT. RM MOUNTING: SURFACE NEMA 1 MAIN CONNECTION: M.L.O. FED FROM; ATS DEVICE FAMILY: SIEMENS OR EQUAL DESCRIPTION g um P COANNECTED NO. No. COANNECTEDBA P am DESCRIPTION BA WELL WATER PUMP 12 20 2 1.15 1 2 1.2 1 20* 12 UR-OFFICE/BDRM 12 1.16 3 4 1.44 1 20* 12 L/R-BDRM/HALL GENERATOR CONTROL 12 20 1 0.94 5 6 1.14 1 20* 12 L/R-BDRM R-GENERATOR CONV 12 20 1 0.18 7 8 1.1 1 20 12 MICROWAVE SPARE 20* 1 0 9 10 1.2 1 20 12 R-REFRIGE, WINE COOLER SPACE 0 11 12 0 SPACE ATTIC AHU-2 4 70 2 0.92 13 14 4.13 1 1 20 12 CU-2 ON LOAD SHED 4 0.92 15 16 4.13 1 20 12 ON LOAD SHED 0 17 18 0 G.D.O. SOUTH 12 20 1 1.58 19 20 1.96 2 30 10 ELEVATOR MOTOR G.D.O. NORTH 12 20 1 1.58 21 22 1.96 10 GOLF CART CHARGER 12 20 1 1.05 23 24 0.45 1 20 12 ELEVATOR CONTROLLER L/R ELEVATOR PIT 12 20 1 0.33 25 26 0 EWH (EXISTING) 10 30 2 2.25 27 28 17.06 2 125 1 PANEL "El" (ON LOAD SHED) 101 2.25 1 29 1 30 16.56 1 7.17 7.13 TOTAL 26.19 26.14 66.63 TOTALKVA SERVES CONNECTED LOAD - KVA DF CALCULATED DEMAND - KVA GENERAL LIGHTING (FIRST 3 KVA) 3.00 1.00 3.00 GENERAL LIGHTING (3 KVA TO 120 KVA) 15.39 0.35 5.39 LARGEST MOTOR 8.26 1.25 10.33 OTHER MOTORS 21.44 1.00 21.44 EQUIPMENT/HEAT 13.44 1.00 13.44 APPLIANCE LOAD 2.80 0.75 2.10 TOTAL DEMAND KVA: 55.69 TOTALAMPERAGE: 232.05 NOTES: 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO BIDDING AND INSTALLATION. 2. PROVIDE TYPE WRITTEN DIRECTORY ON INSIDE PANEL COVER 3. NON -COINCIDENT LOAD. CALCULATION BASED ON AIR CONDITIONING MODE WITH I_1. 4. DUE TO THE VERY INTERMITTENT OPERATION OF MANY LOADS, EXPECTED MAXIMUM LOAD IS LESS THAN 480 AMPS. S. THESE LOADS ARE PRIMARILY TRANSFERRED FROM PANEL "PA". 6. KW DEMAND WHEN SUPPLIED BY THE GENERATOR 15 LIMITED TO 34.16 KW, WITHIN THE 36 KW CAPACITY OF THE GENERATOR. GIVEN ONLY OCCASIONAL OPERATION OF THE ELEVATOR, LOAD SHEDDING OF HVAC-2 IS NOT EXPECTED. PANEL: E1 VOLTAGE: 120/240V 1PH 3W BUSIBREAKER AIC RATING: 22KA/10KA RATING: 125A LOCATION: NEW ADDITION GARAGE MOUNTING: SURFACE NEMA 1 MAIN CONNECTION: M.C.B. FED FROM: PANEL "E" DEVICE FAMILY: SQ D QO OR EQUAL DESCRIPTION = 9 g0 Y um P COANNECTED KVBA NO NO. CONNECTED P m DESCRIPTION B GENERATOR CONTROL 12 20 1 0.94 1 2 1.20 1 20 12 L-GARAGE R-GENERATOR CONV. 12 20 1 0.18 3 4 1.09 1 20 12 L-GARAGE WORK AREA G.D.O. NW 12 20 1 1.58 5 6 0.96 1 20 12 L-GARAGE STORAGEIWORK G.D.O. NE 12 20 1 1.58 7 8 0.60 1 20 12 L-WALKWAY 1ST FL G.D.O. E 12.20. 1 1.58 9 10 0.53 1 20* 12 L-FOYER, STAIRS R-KITCHEN APP 12 201 1 1.50 11 12 0.83 1 20* 12 L-MASTER BDRM R-WORK RM ISLANDS 12 201 1 0.64 13 14 0.66 1 20* 12 L-MASTER BATHROOM R-MASTER BDR 12 20* 1 1.66 15 16 0.81 1 20 12 L-KITCHEN/LAUNDRY R-MASTER BATH 12 20 1 0.54 17 18 1.00 1 20 12 L-WALKWAY 2ND FL R-OFFICE 12 20* 1 0.90 19 20 1.15 1 20 12 LAUNDRY R-GOLF CART CHARGER 12 20 1 1.05 21 22 0.00 SPACE REFRIGERATOR 12 20 1 0.50 23 24 2.26 2 30 10 EWH SPACE 0.00 25 261 2.25 10 HVAC-CU-4 8 50 2 3.87 27 Mgj 0.00 2 1201121 AHU-4 FAN (ON LOAD SHED) 1 8 1 1 3.87 29 301 0.00 12 (ON LOAD SHED) 10.10 10.19 TOTAL F 6.59 6.72 33.595 TOTALKVA SERVES CONNECTED LOAD - KVA DF CALCULATED DEMAND - KVA GENERAL LIGHTING (FIRST 3 KVA) 3.00 1.00 3.00 GENERAL LIGHTING (3 KVA TO 120 KVA) 11.09 0.35 3.88 LARGEST MOTOR 7.74 1.25 9.68 OTHER MOTORS 4.78 1.00 4.78 EQUIPMENT/HEAT 6.49 1.00 6.49 APPLIANCE LOAD 0.50 0.75 0.38 28.20 TOTAL DEMAND KVA: TOTALAMPERAGE: 117.50 NOTES: 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO BIDDING AND INSTALLATION. 2. PROVIDE TYPE WRITTEN DIRECTORY ON INSIDE PANEL COVER *-DENOTES PROVIDE AFCI TYPE BREAKER 3. NON -COINCIDENT LOAD. CALCULATION BASED ON HEATING MODE. PANEL: "PA1" NEW VOLTAGE: 120/24OVlPH 3W BUS/BREAKER AIC RATING: 22KA/30KA RATING: 200A LOCATION: MECH/ELECT RM. MOUNTING: SURFACE - NEMA 1 MAIN CONNECTION: M.L.O. DEVICE FAMILY: SQUARE D - QO OR EQUAL FED FROM: WIREWAY DESCRIPTION 9. $" x O m P CONNECTED KVA No. No. CONNECTED KVA P O m 9 § w DESCRIPTION A B A B HVAC-MS-I-INDOOR/OUTDOOR 12 15 2 1.38 1 2 2.33 2 30 10 HVAC-CU-3 UNITS - MOCP=15A 12 1.38 3 4 2.33 10 MCA=20.3 R-GARAGE CEILING S 12 20 1 0.18 5 6 4.21 2 50 8 HVAC-AHU-3 R-GARAGE CEILING N 12 20 1 0.18 7 8 4.21 8 FAN=.5HP,HTR.=7.3 KW R-GARAGE NE 12 20 1 0.18 9 10 1.08 1 20* 12 R-ENTRY/FOYER,EXT. R-EXERCISE ROOM -WEST 12 20* 12 0.54 11 12 0.72 1 20 12 R-GARAGE, EXTERIOR R-EXERCISE ROOM -EAST 12 20* 1 1 0.72 13 14 0.72 1 20 1 12 R-PORT COCHERE R-WASHER 12 20 1 1.16 15 161 0.72 1 20* 12 R-MECH/ELEC. ROOM R-IRONING BOARD 12 20* 1.50 17 18 0.00 SPACE SPACE 0.00 19 20 0.00 R-LAUNDRY ROOM 12 20* 1 0.72 21 22 0.00 R-FOYER,HALL,TRASH RM. 12 20* 1 0.90 23 24 0.00 L-EXERCISE RM, STOR.,POOL RM 12 20* 1 0.64 25 26 0.60 1 20 12 L-PORTE COCHERE L-GARAGE 12 20 1 1.00 27 28 0.70 1 20* 12 L-FOYER,HALL L-PRIV. ENTRY,EXTERIOR 12 20* 1 0.50 29 30 0.81 1 20* 12 L-LAUNDRY,CLO.,STOR.,GALLER L-EXTERIOR WALL LIGHTS 12 20 1 0.70 31 32 1.08 1 20* 12 R-SEATING - 2ND FL R-ENTRY FOYER, HALLWAY 12 20* 1 1.26 33 34 0.00 1 20 SPARE SPARE 20* 1 0.00 35 36 0.00 1 20* SPARE SPACE 0.00 37 38 0.00 SPACE SPACE 0.00 39 40 0.00 SPACE SPACE 0.00 1 41 42 0.00 SPACE 6.98 1 5.85 TOTAL 9.75 9.76 32.35 TOTALKVA SERVES CONNECTED LOAD - KVA OF CALCULATED DEMAND - KVA GENERAL LIGHTING(FIRST 3 KVA) 3.00 1.00 3.00 GENERAL LIGHTING (3 KVA TO 120 KVA) 13.50 0.35 4.73 LARGEST MOTOR 3.92 1.25 1 4.90 OTHER MOTORS 3.89 1.00 3.89 EQUIPMENT/HEAT 7.30 1.00 7.30 APPLIANCE LOAD 0.00 0.75 0.00 TOTAL DEMAND KVA: 23.82 TOTALAMPERAGE: 99.21 NOTES: 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO BIDDING AND INSTALLATION. 2. PROVIDE TYPEWRITTEN DIRECTORY ON INSIDE PANEL COVER *-DENOTES PROVIDE AFCI TYPE BREAKER -- PANEL: NEW VOLTAGE: 120/240V 1PH 3W BUS/BREAKER AIC RATING: 22KA/10KA RATING: 200A LOCATION: GARAGE MOUNTING: SURFACE - NEMA 1 MAIN CONNECTION: 200A M.C.B. FED FROM: FPL TRANSFORMER DEVICE FAMILY: SQUARE D - QO OR EQUAL DESCRIPTION § a m P CONNECTED KVA No. No. CONNECTED KVA P U m �' DESCRIPTION A B A B DRYER 10 30 2 2.70 1 2 1.26 1 20 12 R-GARAGE 10 12 20* 1 1.50 2.70 3 5 4 6 1.08 1.08 1 1 20* 20* 12 12 R-STOR/WK RM.,TRASCH,WK AREA R-WK/STORAGE R-IRONING BOARD R-ICE MAKER-2ND FL. 12 20* 1 0.70 7 8 1.50 1 20 12 R-KITCHEN APPLIANCE CIRCUIT R-LIV. RM. 12 20* 1 1.44 9 10 0.00 SPACE R-STAIRWAY, STORAGE 12 20* 1 1.08 11 12 1.50 1 20 1 12 1 R-DISH WASHER -KITCHEN R-LIVING RM FLOOR 12 20* 1 0.72 13 14 0.00 SPACE R-RANGE 6 50 2 4.00 15 16 1.13 1 20 12 R-GARBAGE DISPOSAL -KITCHEN 6 4.00 17 18 0.24 1 20* 12 L-MASTER BR F-2ND FL COVERED TERRACE 12 20 1 0.32 19 20 0.12 1 20* 12 L-MSTR BR, CLO., SPARE 20 1 0.00 21 22 0.72 1 20* 12 L-LIVING RM,OFFICE SPARE 20* 1 0.00 23 24 0.46 1 20* 12 L-STAIR,FOYERS, CHANDELIERS L-KITCHEN PENDANTS & UC 12 20* 1 0.23 25 26 0.00 1 20 SPARE L-COVERED TERRACE-2ND FL. 12 20 1 0.50 27 28 0.90 1 1 20* 1 12 1 R-ENTRY 212,LAUD. RM,STORE L-COVERED WALKWAY-2ND FL. 12 20 1 0.30 29 30 0.00 1 SPACE L-WALKWAY-1ST FLOOR 12 20 1 0.30 31 32 0.00 SPACE L-COVERED TERRACE -1ST FL. 12 20 1 0.60 33 34 0.00 SPACE R-TERRACE 12 20* 1 0.64 35 36 0.00 SPACE SPACE 0.00 37 38 0.00 SPACE AHU-4 HEAT 8 50 2 4.15 39 40 0.00 SPACE (8.3KW HEAT) 8 4.15 41 42 0.00 SPACE 15.64 14.29 TOTAL 3.30 6.68 39.91 TOTAL KVA SERVES CONNECTED LOAD - KVA DF CALCULATED DEMAND - KVA GENERAL LIGHTING (FIRST 3 KVA) 3.00 2.00 3.00 GENERAL LIGHTING (3 KVA TO 120 KVA) 11.56 0.35 4.04 LARGEST MOTOR 1.13 1.25 1.41 OTHER MOTORS 0.32 1.00 0.32 EQUIPMENT/HEAT 21.70 1.00 21.70 APPLIANCE LOAD 2.20 0.75 1.65 TOTAL DEMAND KVA: 32.13 TOTAL AMPERAGE: 133.86 NOTES: 1. VERIFY ELECTRICAL REQUIREMI NTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO BIDDING AND INSTALLATION. 2. PROVIDE TYPEWRITTEN DIRECTORY ON INSIDE PANEL COVER *-DENOTES PROVIDE AFCI TYPE BREAKER PANEL: "PA"SURFACE EXISTING "MAIN PANEL" VOLTAGE: 120/240V 1PH 3W BUS/BREAKER AIC RATING: 2ZW10KA RATING: 200A LOCATION: MECH. ROOM MOUNTING: MAIN CONNECTION: M.L.O. FED FROM: MDP DEVICE FAMILY: SQUARE D DESCRIPTION P CONNECTED KVA No. Na. CONNECTEOKVA P U DESCRIPTION A B A B L-OUTDOOR STRUCTURES 12 20 1 0.20 1 2 3.73 2 100 NOTE 5 SPACE 0.00 3 4 7.63 _ R-DOUBLE OVEN -EX. 8 50 2 3.50 5 6 0.00 2 40 SPARE 8 3.50 7 8 0.00 AHU-1 8 50 2 4.41 9 10 0.00 2 30 NOTE 6 (8KW HEAT, 1/3HP FAN) 8 4.41 11 1 12 0.00 WATER HEATER -EX. 10 30 2 2.25 13 1 14 0.00 2 20 SPARE 10 2.25 15 16 0.00 A=WASHER,B=SPARE 12 1 20** 2 1.15 17 18 1.44 2 20** 12 A=CENT. VAC,B=EXT. RECS.-EX. A=SPARE,B=UTILITY RM.-EX. 12 20** 2 2.16 19 20 0.80 2 20** 12 A=SPARE,B=RANGE HOOD/KIT. LTS.-EX. A=ICE MAKER,B=LAUND. RM. LTS-EX. 12 20 2 2.10 21 22 4.10 2 20** 12 A=MICRO-WAVE,B=RECS. BY SINK -EX. A=BED RM,B=OFFICE RECS.-EX. 12 20 2 1.44 23 24 1.20 2 20** 12 A=SPARE,B=SPARE R-KITCHEN SECURITY STATION 12 20* 1 0.18 25 26 1.20 1 20** 12 R-TEA KETTLE -EX. R-COFFEE MACHINE -EX. 12 20 1 1.14 27 28 1.50 1 20** 12 R-DISH WASHER -EX. L-LANDSCAPE-EX. 12 20 1 1.10 29 30 1.58 1 20 12 R-DISPOSAL-EX. R-EXTERIOR RECEPTS.-EX. 12 20 1 1.44 31 32 3.20 2 60 6 R-COOK TOP -EX. SPACE 0.00 33 34 3.20 6 SPACE 0.00 35 36 0.00 2 70 NOTE 6 SPACE 0.00 37 38 0.00 SPACE 0.00 39 40 0.00 SPACE SPACE 0.00 41 42 0.00 SPACE 14.89 16.34 TOTAL 15.25 14.33 1 60.81 TOTAL KVA SERVES CONNECTED LOAD - KVA DF CALCULATED DEMAND - KVA GENERAL LIGHTING(FIRST 3 KVA) 3.00 1.00 3.00 GENERAL LIGHTING (3 KVA TO 120 KVA) 17.82 0.35 6.24 LARGEST MOTOR 1.15 1.25 1.44 OTHER MOTORS 0.82 1.00 0.82 EQUIPMENT/HEAT 12.50 1.60 12.50 APPLIANCE LOAD 25.52 0.75 19.14 TOTAL DEMAND KVA: 43.13 TOTALAMPERAGE: 179.73 NOTES: 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO BIDDING AND INSTALLATION. 2. PROVIDE TYPEWRITTEN DIRECTORY ON INSIDE PANEL COVER 3.*-DENOTES PROVIDE AFCI TYPE BREAKER 4. **INDICATES TANDEM CIRCUIT BREAKER S. TRANSFER THIS PANEL TO THE MDP. NOTIFY GC OF RESTORATION WORK. 6. TRANSFER THIS LOAD TO THE MDP. NOTIFY GC OF RESTORATION WORK. PANEL: "MDP" VOLTAGE: 120/240V 1PH 3W BUS/BREAKER AIC RATING: 22KA/lOKA RATING: 600A LOCATION: MECH/ELECT. RM MOUNTING: SURFACE NEMA 1 MAIN CONNECTION: M.C.B. FED FROM: FPL TRANSF. DEVICE FAMILY: SQUARE D I -LINE OR EQUAL DESCRIPTION w w 8 Y am P CONNECTED KVA No. No. CONNECTED KVA P am DESCRIPTION A B A B PANEL "P1" 3/0 200 2 19.96 1 2 29.92 2 225 4/0 PANEL "E" 3/0 19.63 3 4 29.92 4/0 THRU ATS SPA PANEL -EXIST 6 60 2 6.73 5 6 15.81 2 200 3/0 PANEL "PA1" 6 6.76 7 8 16.81 3/0 PUMP PANEL - EXIST. 6 60 2 1.15 9 10 30.01 2 200 3/0 PANEL "PA" - EXIST MAIN PANEL 6 1.15 11 12 30.01 3/0 0 13 14 3.73 2 100 3 PANEL 2ND FLOOR CLOSET 0 1 15 16 7.63 3 0 17 18 2.7 2 30 10 CLOTHES DRYER 0 19 20 21 10 0 21 22 0 0 23 24 0 0 25 26 0 0 27 28 0 0 29 30 0 27.84 27.54 TOTAL 82.17 86.07 1 223.62 TOTALKVA SERVES CONNECTED LOAD - KVA DF CALCULATED DEMAND - KVA GENERAL LIGHTING (FIRST 3 KVA) 3.00 1.00 3.00 GENERAL LIGHTING (3 KVA TO 120 KVA) 78.97 0.35 27.64 LARGEST MOTOR 3.92 1.25 4.90 OTHER MOTORS 39.83 1.00 39.83 EQUIPMENT/HEAT 15.24 1.00 15.24 APPLIANCE LOAD 30.52 0.75 22.89 FIXED ELECTRIC SPACE HEATING 24.50 0.65 15.93 TOTAL DEMAND KVA: 129.42 TOTALAMPERAGE: 539.27 NOTES: 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH MANUFACTURER'S MANUAL PRIOR TO BIDDING AND INSTALLATION. 2. PROVIDE TYPE WRITTEN DIRECTORY ON INSIDE PANEL COVER 3. NON -COINCIDENT LOAD. CALCULATION BASED ON HEATING MODE. 4. DUE TO THE VERY INTERMITTENT OPERATION OF MANY LOADS, EXPECTED MAXIMUM LOAD IS LESS THAN 480 AMPS. U a U of 0 z 0 m w w Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 6724637 TD m o O m m o z a o Ca W J d V O IL O 3 w I- W Cn Q J O 1- U W N Cn z O E'+ A W z o rn W °' a Q o m W z a o Ems+ o E Q o I,J o zz W LL O _j -} U C%] 1- L1.1 F- L) o O 'O _J CL a a a .� M ENGINEER SEAL ®a C. T 9'i��r S No 6 4IIIEW 2 0 6/95Ir z O `STAY 50F . LU.: Timothy C. Trewyn, PE P.E. No. 61580 TESE mL1AENTS, N WH TIE CIN: M W M ZSIM MsDffUl I m NE IIHFHOEO IFEI Fm TIE SKC6S PI.INOSE NO CUD7 6 FORT PIERCE ENOIE W, OIC M wo T V PRO' A IB OFRfPER RDgNCE a SHEET TITLE ELECTRICAL SCHEDULES & CALCULATIONS 1" " ` 06-12-2015 I DRAWN: TEC APPROVED: TCT DRAWING NUMBER ) c SHEET 8 OF 8 15020-02 DUCTWORK SYSTEM SYMBOLS SYMBOL DESCRIPTION ® LN SUPPLY AIR DUCT SECTION (UP/DOWN) z©j RETURN, OUTDOOR OR EXHAUST AIR DUCT SECTION (UP/DOWN) z©j OUTDOOR AIR DUCT SECTION (UP/DOWN) z©j EXHAUST AIR DUCT SECTION (UP/DOWN) RETURN, EXHAUST OR TRANSFER AIR FLOW - SUPPLY AIR FLOW MD ❑ MOTORIZED DAMPER VD MANUAL VOLUME DAMPER FD [>- FIRE DAMPER SD >- SMOKE DAMPER AD Q ACCESS DOOR FLEXIBLE DUCT CONNECTION ELBOW WITH TURNING VANES SUPPLY DIFFUSER WITH 4-WAY BLOW SUPPLY DIFFUSER WITH 2-WAY BLOW SUPPLY DIFFUSER WITH QUADRANT BLOCK SD - SIDEWALL DIFFUSER Fol RETURN, TRANSFER OR EXHAUST GRILLE OR REGISTER ® EXHAUST FAN ROUND CEILING DIFFUSER LINEAR DIFFUSER CDP-1 AIR DEVICE, TYPE AND CAPACITY 100 SQUARE TO ROUND TRANSITION - EXISTING DUCTWORK OR EQUIPMENT TO REMAIN - -- -- -- EXISTING DUCTWORK OR EQUIPMENT TO BE REMOVED NEW DUCTWORK OR EQUIPMENT OROOF CENTRIFUGAL FAN, EXHAUST OROOF CENTRIFUGAL FAN, SUPPLY ELECTRIC DUCT HEATER UNDERCUT CONTROL SYMBOLS THERMOSTAT - 5-0" A.F.F. MOUNTING HEIGHT HUMIDISTAT - 5'-0" A.F.F. MOUNTING HEIGHT �- TEMPERATURE SENSOR �- STATIC PRESSURE SENSOR ® DUCT SMOKE DETECTOR /VD VOLUME DAMPER /AD AUTO DAMPER HVAC PIPING LEGEND -CWR- CONDENSER WATER RETURN -CWS- CONDENSER WATER SUPPLY -CHWS- CHILLED WATER SUPPLY -CHWR- CHILLED WATER RETURN HOT WATER SUPPLY -HWS- HOT WATER RETURN -HWR- - - - - - REFRIGERANT PIPING CONDENSATE DRAIN FROM COOING COIL CD DOMESTIC COLD WATER - - - G GAS PIPING MECHANICAL SYMBOL LEGEND SCHEDULE FORSUPPLY 4 WAY BLOW 2 WAY BLOW A QUADRANT BLOCK SYMBOL 0 NECK CDP-1 6" CDP-2 8" CDP-3 10" CDP-4 12" FLEX CONNECTION CFM RANGE FINISH REMARKS 6" 0 - 125 OFF-WHITE O O 8" 126 - 225 OFF-WHITE OA OB 10" 226 - 400 OFF-WHITE O O 12" 401 - 600 OFF-WHITE (D OB I SCHEDULE FOR 24"X24" CEILING RETURN DIFFUSER SYMBOL 1 0 NECK 1 19 RD-1 6" RD-2 B. RD-3 10" RD-4 12" RD-5 14" RD-6 16" FLEX CONNECTION CFM RANGE FINISH REMARKS 6" 0 - 125 OFF-WHITE OC 8" 126 - 225 OFF-WHITE O 10" 226 - 400 OFF-WHITE OC 12" 401 - 600 OFF-WHITE OC 14" 601 - 900 OFF-WHITE OC 16" 901 - 1250 OFF-WHITE n REMARKS: A. ALL SUPPLY DIFFUSERS SHALL BE 4-WAY BLOW UNLESS OTHERWISE SHOWN, METALAIRE 5000, OR EQUAL BY TITUS. B. DO NOT INSTALL DAMPER IN DIFFUSERS USE DAMPER AT FLEX TAKE -OFF TO BALANCE AIR FLOW. C. ALL RETURN DIFFUSERS SHALL BE METALAIRE RH, OR EQUAL BY TITUS. SPLIT SYSTEM EQUIPMENT SCHEDULE AIR HANDLERS DESIGNATION AHU-3 AHU-4 PROTOTYPE MANUFACTURER MODEL LENNOX CBX32MV-036 LENNOX CBX32MV-048 WEIGHT (POUNDS) 180 200 NOM. TONS 3 4 SYSTEM CAPACITY (BTU/HR) TOTAL / SENSIBLE 31,362 / 26,235 43,867 / 36,744 TOTAL AIR FLOW (CFM) 1,125 1,600 SEER 21.5 20.5 EXTERNAL STATIC PRESSURE 0.811 0.8.. COIL EAT•F db/wb 7 / / -927 COIL LAT `F db/wb 51.6 / 51.2 52.0 / 51.5 FAN MOTOR HP 1/2 H.P. I H.P. AUX. HEATER, KW STAGES I 7.3KW / 2 1 8.3KW / 2 ELEC-VOLTS/PHASE/ MCA/ MOCP 230 / I / 47 / 50 I 230 / I / 58 / 60 CONDENSING UNITS - HEAT PUMP (R-410A) DESIGNATION CU-3 CU-4 PROTOTYPE MANUFACTURER LENNOX LENNOX MODEL XP25-036-230 XP25-048-230 PIPE SIZE, SUCTION/LIQUID, IN. 3/4" / 3/8" 7/8" / 3/8" ELEC-VOLTS/PHASE/MCA/MOCP 230 / 1 / 20.3 / 30 230 / 1 / 33.7 / 50 NOTES: I. AIR HANDLER & CONDENSING UNIT SAME MANUFACTURER. 2. ALL EQUIPMENT TO COMPLY WITH FLORIDA ENERGY CODE. 3. EQUIPMENT MANUFACTURER LISTED IS USED AS THE BASIS OF DESIGN eI IS NOT INTENDED TO LIMIT COMPETITION. 4. CONDENSING COILS TO HAVE "ULTRA -GUARD" COASTAL CORROSION RESISTANT COATING. 5. PROVIDE FREEZE STAT ON INDOOR COILS. 6. SYSTEMS SHALL HAVE INVERTER DRIVE, VARIABLE CAPACITY COMPRESSORS WITH VARIABLE SPEED AIR HANDLERS. 7. PROGRAM AHUS FOR GRADUAL FAN SPEED RAMP -UP TO FULL AIRFLOW WHEN SYSTEM CYCLES ON, IMMEDIATE STOP WHEN SYSTEM CYCLES OFF. B. SYSTEM'S COMPRESSOR CAPACITY a AIR HANDLER AIRFLOW SHALL VARY BASED ON COOLING DEMAND. 9. PROVIDE LENNOX "i-COMFORT" DIGITAL TOUCH SCREEN / Wi-Fi PROGRAMMABLE THERMOSTATS WITH INTEGRAL HUMIDISTAT FOR "COOLING FOR DEHUMIDIFICATION" CAPABILITY & REMOTE THERMOSTAT. TEMPERATURE SHALL BE AVERAGED BETWEEN MASTER a REMOTE THERMOSTAT. 10. INSTALL CORROSION "GRENADE" ON SUCTION LINE AT EACH COMPRESSOR. 11. PROVIDE "APRILAIRE" OR EQUIVALENT ONCE -A -YEAR FILTER FOR EACH STANDARD SYSTEM. FILTER SHALL BE LOCATED AT AHU RETURN, NO FILTERS IN RETURN GRILLS. 12. ELECTRIC HEATER SHALL BE ENABLED ONLY WHEN HEAT PUMP COMPRESSOR HAS BEEN DISABLED - HEAT PUMP COMPRESSOR SHALL NOT OPERATE SIMULTANEOUSLY WITH EMERGENCY ELECTRIC HEATER IN AIR HANDLER. MS -I: FUJITSU 12RLECD 12,000 BTU MINI SPLIT HEAT PUMP SYSTEM MS -I OUTDOOR FUJITSU AOUI2RLFC, HEAT PUMP R-410A, 20 SEER, 12,000 BTU, 230V-10, 15 MOCP. INVERTER DRIVE VARIABLE SPEED COMPRESSOR WITH VARIABLE CAPACITY. SUCTION LINE 3/8", LIQUID LINE 1/4". MS -I INDOOR FUJITSU ARU12RLF, SLIM DUCT, 12,000 BTU, 380 CFM. UTILIZE MANUFACTURER PROVIDED THERMOSTAT. INDOOR UNIT SHALL BE INSTALLED VERTICALLY ON FLOOR WITH RETURN LOW THRU WALL 81 SUPPLY DUCTED TO HIGH LOCATION THRU WALL. NOTE: SOME NOTES & SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. REFRIGERANT PIPING NOTES 1. REFRIGERANT PIPING SHALL BE TYPE "K" OR "L" SOFT DRAWN COPPER TUBING WITH WROUGHT COPPER SOLDER TYPE FITTINGS SUITABLE FOR CONNECTION WITH SILVER SOLDER. 2. COOLING COIL DRIP PIPING SHALL BE TYPE "M" COPPER OR SCHEDULE 40 PVC. PROVIDE 4" DEEP TRAP. 3. PROVIDE ALL VALVES AND SPECIALTIES AS SHOWN BY THE DETAILS AND AS REQUIRED FOR A COMPLETE OPERATING REFRIGERATION SYSTEM. 4. VALVES AND SPECIALTIES SHALL BE AS FOLLOWS: 4.1. AGLOBE VALVES, FORGED BRASS, BACKSEATING TYPE 500 PSI 4.2. CHECK VALVES, FORGED BRASS, 500 PSI 4.3. SOLENOID VALVES, FORGED BRASS, 400 PSI 4.4. REFRIGERANT STRAINERS, BRASS, 350 PSI, 100 MESH STRAINER 4.5. MOISTURE INDICATOR, FORGED BRASS, OPTICAL GLASS, 500 PSI 4.6. FILTER DRYER, STEEL SHELL, REPLACEABLE FILTER DRYER 5. REFRIGERANT PIPING JOINTS: ALL JOINTS SHALL BE MADE WITH SILVER SOLDER. THE PIPING SHALL BE CHARGED WITH DRY NITROGEN WHILE CONSTRUCTING THE JOINTS. A REMOVABLE TYPE DRYER STRAINER SHALL BE INSTALLED IN THE LIQUID UNE. A THREE WAY VALVE BY-PASS SHALL BE PROVIDED FOR THE STRAINER, AFTER THE REFRIGERANT PIPING HAS BEEN COMPLETED, THE REFRIGERANT SYSTEM SHALL BE PRESSURE TESTED WITH NITROGEN AT A PRESSURE OF 300 PSI (HIGH SIDE) AND 150 PSI (LOW SIDE). WHILE THE SYSTEM IS BEING PRESSURE TESTED, AN ELECTRONIC LEAK DETECTOR SHALL BE USED TO CHECK FOR LEAKS. PRESSURE SHALL BE MAINTAINED ON THE SYSTEM FOR A MINIMUM OF 12 HOURS. THE SYSTEM SHALL THEN BE EVACUATED TO 2.0 MM MERCURY AND THEN CHARGED AND MADE READY FOR INSULATION. 6. PIPING EXPANSION AND VIBRATION ELIMINATION: PROVIDE REFRIGERANT TYPE FLEXIBLE CONNECTIONS AT THE AIR HANDLER AND AT THE CONDENSING UNIT. THE CONNECTORS SHALL BE AT LEAST 12" IN LENGTH AND SHALL BE LOCATED TO EFFECTIVELY CONTROL VIBRATION AND TO ALLOW FOR CHANGES IN PIPE LENGTH. PIPE INSULATION NOTES 1. THE REFRIGERANT SUCTION LINES SHALL BE INSULATED WITH 1" THICK "ARMAFLEX", OR EQUAL THE SUC11ON LINE SHALL BE INSULATED IN ITS ENTIRETY INCLUDING VALVES AND SPECIALTIES. VALVES AND SPECIALTIES THAT REQUIRE ACCESS SHALL HAVE SPECIAL REMOVABLE COVERS. 2. ALL INSULATION SHALL. BE VAPOR SEALED AND BUTT JOINTS OF "ARMAFLEX" SHALL BE TAPED TO PREVENT INTRUSION AT THE JOINT. 3. SADDLES SHALL BE USED AT ALL PIPE HANGERS TO PREVENT COMPRESSION OF THE INSULATION. ELECTRICAL CONNECTION NOTES 1. COORDINATE POWER WIRING AND CONDUIT FROM PANEL THRU FUSED DISCONNECT TO UNIT WITH ELECTRICAL. 2. COORDINATE THE FUSED DISCONNECTS WITH ELECTRICAL. 3. MAKE FINAL CONNECTIONS TO AIR HANDLING UNIT WITH "GREENFIELD". MAKE FINAL CONNECTION TO CONDENSING UNIT WITH "UQUIDTITE". FINAL CONNECTIONS SHALL BE A MINIMUM OF 3 FT. 4. ALL WIRING SHALL BE COPPER. SEE ELECTRICAL DRAWINGS FOR WIRE SIZE. 5. CONTROL WIRING SHALL BE RUN IN CONDUIT. 6. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONTROL WIRING. 7. AIR HANDLING UNIT SHALL BE PROVIDED WITH SINGLE POINT OF ELECTRIC ENTRY. B. MECHANICAL CONTRACTOR SHALL PROVIDE MOTOR STARTER AND HEATER CONTACTORS IN CONTROL PANEL EXHAUST FAN SCHEDULE SYMBOL DESCRIPTION BROAN QTXE050, 50 CFM W/ BACKDRAFT DAMPER. EF-I PROVIDE SEPARATE SWITCH. 120V-1o, 0.3A BROAN QTXEI50, 150 CFM W/ BACKDRAFT DAMPER. EF-2 PROVIDE SEPARATE SWITCH. 120V-1o, 0.5A 1. PRIOR TO SUBMITTING A BID, THE CONTRACTOR SHALL VISIT THE JOB SITE TO THOROUGHLY FAMILIARIZE HIMSELF WITH THE EXISTING FIELD CONDITIONS AND PHYSICAL CONSTRAINTS ASSOCIATED WITH THE WORK TO BE ACCOMPLISHED UNDER THIS CONTRACT. 2. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS: FLORIDA MECHANICAL CODE 2010 ED, FLORIDA ENERGY CODE, NFPA-90A STANDARDS FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS, SMACNA DUCT CONSTRUCTION STANDARDS, ASHRAE 62.1 3. VERIFY FINAL LOCATIONS FOR ROUGH -INS WITH FIELD MEASUREMENTS AND WITH REQUIREMENTS OF THE ACTUAL EQUIPMENT TO BE INSTALLED. 4. COORDINATE THE CUTTING AND PATCHING OF BUILDING COMPONENTS TO ACCOMMODATE THE INSTALLATION OF HVAC EQUIPMENT AND MATERIALS. 5. PROVIDE WEATHER PROTECTION FOR ALL EQUIPMENT AND MATERIALS STORED ON SITE, 6. VENTILATION DUCTWORK SHALL BE SHEET METAL AND INSTALLED IN ACCORDANCE WITH SMACNA. ALL OTHER DUCTWORK SHALL BE AS SHOWN ON THE PROJECT PLANS. DUCTWORK INSULATION SHALL COMPLY WITH THE FLORIDA ENERGY CODE. 7. REFER TO ELECTRICAL CEILING GRID LIGHTING PLAN FOR EXACT LOCATION OF AIR DISTRIBUTION DEVICES B. PROVIDE ALL DUCT TRANSITIONS REQUIRED TO CONNECT EQUIPMENT SHOWN TO DUCT SYSTEMS. 9. PROVIDE DUCT MOUNTED SMOKE DETECTORS ON THE SUPPLY OF ALL AIR HANDLING SYSTEMS 2000 CFM AND GREATER. 10. PROVIDE AIR BALANCE TO QUANTITIES SHOWN ON THE PLANS. PROVIDE ALL VOLUME DAMPERS REQUIRED TO ACCOMPLISH AIR BALANCE. --SUBMIT BALANCE REPORT FOR REVIEW 11. SYSTEM TEST At BALANCE REPORT TO BE INCLUDED WITH INSTALLATION PROVIDE REPORT TO OWNER AND ENGINEER FOR REVIEW INSTALLATION WILL NOT BE CONSIDERED COMPLETE WITHOUT T&B REPORT FIBRE DUCT INSTALLATION DETAILS DUCT CONSTRUCTION NOTES 1. ALL DUCT WORK, DUCT FITTINGS, DUCT FLEXIBLE CONNECTIONS, AND FLEXIBLE DUCT SHALL BE CONSTRUCTED AND INSTALLED, AS A MINIMUM, IN ACCORDANCE AND WITH THE STANDARDS AND RECOMMENDATIONS OF "SMACNA" LATEST PUBLICATIONS AND STANDARDS 2. ALL DUCT WORK SHALL BE CONSTRUCTED OF 1-1/2" FIBRE BOARD EXCEPT EXHAUST DUCTS WHICH SHALL BE SHEET METAL FIBRE DUCTS SHALL BE CONSTRUCTED WITH 1-1/2" BOARD WITH ANTI -FUNGAL INTERIOR COATING. 3. DUCT HANGERS AND SUPPORTS SHALL COMPLY WITH "SMACNA" STANDARDS IN GENERAL, HOWEVER, DUCT STRAPS SHALL BE USED UP TO 48" IN HORIZONTAL DIMENSION (OR ROUND). DUCTS GREATER THAN 48" SHALL BE SUPPORTED WITH TRAPEZE HANGERS AND STEEL RODS. 4. ALL DUCTS SHALL BE OF THE SIZE AND SHAPE AS SHOWN BY CONTRACT DOCUMENTS 5. ALL FLEXIBLE DUCTS SHALL COMPLY WITH UL 181. FLEX DUCTS SHALL NOT BE GREATER IN LENGTH THAN 10'. WHERE LENGTHS GREATER THAN 10' ARE SHOWN ON THE PLANS INSTALL ROUND SHEET METAL To WITHIN 10' OF THE DEVICE BEING SERVED. 6. SHEET METAL TURNING VANES SHALL BE PROVIDED IN ALL SUPPLY AND RETURN RECTANGULAR DUCT WITH ANGLES GREATER THAN 30DEG . 7. DUCTWORK PENETRATING FIRE RATED WALLS SHALL BE EQUIPPED WITH FIRE DAMPERS. NO OPENINGS WITHIN 5' ON EITHER SIDE OF THE FIRE RATED WALL. DUCTWORK ON EACH SIDE OF A FIRE RATED WALL (5) SHALL BE A MINIMUM OF 26 GA. SHEET METAL 8. ALL DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS DUCT INSULATION NOTES 1. ALL INSULATION SHALL COMPLY WITH THE *FLORIDA ENERGY CODE" LATEST EDITION. 2. FLEXIBLE DUCTS SHALL BE OF THE LOW PRESSURE FACTORY FABRICATED TYPE CONSISTING OF A ZINC COATED SPRING STEEL HELIX NON-PEFORATED INNER LINING AND 1-1/2" THICK FIBERGLASS INSULATION WITH METALIZED MYLAR VAPOR BARRIER. 3. ALL INSULATION SHALL HAVE A MAXIMUM FLAME SPREAD/ SMOKE DEVELOPED RATING OF 25/50 4. DUCT SUPPORT HANGERS SHALL PASS AROUND THE OUTSIDE OF THE INSULATION USING SHIELDS OR SADDLES SO AS NOT TO COMPRESS THE INSULATION MECHANICAL DRAWING INDEX SHEET DESCRIPTION I ISSUED M-1 HVAC GENERAL NOTES, SYMBOLS a SCHEDULES YES M-2.1 MECHANICAL HVAC EXISTING / DEMO PLAN YES M-2.2 MECHANICAL HVAC IST FLOOR PLAN YES M-2.3 MECHANICAL HVAC 2ND FLOOR PLAN YES M-3 MECHANICAL HVAC DETAILS YES to 16 Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax:772 672-4637 u o J M m a a w 0 Q°o 0 3 w z rr w z U) Q z O U P] N (n z O E� W U 0 Z En W 61 Q o v W z ¢ 0 W 0 tr E Q ~ W O z Z L) w 0 0 O J U (/] H W Z U a v Ld O 0 � t1 ti Of M a ENGINEER SEAL �SVO .e0©am .vim»• C'"� � '". 82 �^ STAT'JOF v Eric J. Svoboda, PE P.E. No. 60982 THESE DOCUENTS, f1RL VIM THE CONCEPTS AM OR ➢ESI6M PRESENTED I EM ORE IMEMED • Y FOR THE SPECIFIC PURPOSE AND CLIENT OF FORT PIERCE EMIEERIM, M. FIX WHICH TIEY WERE PREPARED. REME OR DIPROPER RELINCE IN THESE DOCLIERIS WITHOUT WRITTEN ACr RC%TaN AM ACOPTRTION BY FORT PIERCE ENOMEPoNO, INC. SHNLL RE WITIWT LI"BiLITY TO THE SHE. COPNW(D2015, FORT PIERCE EIEINEERINO, HNC FILL RAMS RESERM SHEET TITLE HVAC GENERAL NOTES, SYMBOLS & SCHEDULES 11- -1; 06-12-2015 DRAWN: EJS APPROVED: EJS DRAWING NUMBER M - 1 SHEET I OF 5 15020-02 w a Y U K 0 2.5 TON 5 TON SILL 0--z „H\/AC EXISTING/DEMO FLAN IST FLOOR SCALE 1/8" = I'-O" "H\/.4C EXISTING/DEMO FLAN 2ND FLOOR SCALE 1/8" = 1'-0" GENERAL NOTES: I. ALL EXISTING HVAC EQUIPMENT, DUCTWORK, AIR DEVICES, ETC. TO REMAIN UNLESS NOTED OTHERWISE. KEY NOTES: lO EXISTING 2.5 TON AHU WITH RETURN THRU LOUVERED DOOR. 2O EXISTING 5 TON AHU ABOVE CEILING. 3O EXISTING SIDEWALL SUPPLY REGISTER TO BE RELOCATED - ADJUST DUCTWORK AS NECESSARY - SEE SHEET M-2.2 FOR NEW LOCATION. ® EXISTING RANGE HOOD EXHAUST VENT TO BE RELOCATED. SEE SHEET M-2.3 5O EXISTING RANGE HOOD EXHAUST TERMINATION TO BE REMOVED / RELOCATED. © EXISTING DRYER VENT TO BE REMOVED. w a 0 6 z vort rierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No.28173 315 South 7th Street Fort Pierce, FL. 34950 Phone:772 672-4636 Fax: 772 672-4637 0) H rn v o 0) F J M U M Q z a o A W J O O L- W ~ Z < v a o � U M N (n z C H ra Q w z 0) 0) w Q o� M w;!? z o �o a 0 � aLµY.,1 � W O z Z 0 W O J � F- U i/� w a U O /+T~ Ld O sr O Ir M a ENGINEER SEAL ���s�►e � n � $�6 �'f.. 0 09812 STATE yOfi. A, � ` .,< q R { O Q,"• ova`` Of4Al.��t� Eric J. Svobodo, PE P.E. No. 60982 THESE D OUTS, W WD VITH THE E EPTS AND W DESIMS PRESENTED IEIEIN WE INTERRED REY FOR THE SPECIFIC WEE AND CLBFM OF UT PIERCE ENGDEFRX Me FM VHICN TIEY VERE PPEPARER REUSE OR BBRWER RELIWICE W THESE DOCIMMS VITNWT WITTEN AUT ZOW PIW ADAPTATION BY FEW PME ENLREERINO, X SNALL BE V T LIMRITY TD TIE SANE. TXEIRIFMOM, FORT PIERCE ENH➢EERMO, IK. ALL RE RESERVED. I SHEET TITLE I HVAC DEMO PLAN I" ": 06-12-2015 I DRAWN: EJS APPROVED: EJS I DRAWING NUMBER I rlll SHEET 2 OF 5 15020-02 I a a Y U E N 0 U O ST FLCCR SCALi= 1/8" = 1'-0" GENERAL NOTES: I. ROUTE REFRIGERANT LINES FROM MS-1 INDOOR UNIT THRU EXTERIOR WALL TO OUTDOOR UNIT, ROUTE REFRIGERANT LINES FROM AHU-3 UP ABOVE CEILING, THEN DOWN a THRU EXTERIOR WALL TO CU. 2. ROUTE 3/4, CONDENSATE DRAIN FROM MS-1 INDOOR UNIT THRU EXTERIOR WALL a TERMINATE ABOVE GROUND IN LANDSCAPE AREA. ROUTE I' CONDENSATE DRAIN FROM AHU-3 BELOW FLOOR TO EXTERIOR a TERMINATE ABOVE GROUND IN LANDSCAPE AREA - COORDINATE WITH PLUMBING CONTRACTOR. 3. COORDINATE EXACT AIR DEVICE LOCATIONS WITH LIGHTING LAYOUT. 4. PROVIDE PLENUM BOX ABOVE AIR DEVICES FOR SIDE CONNECTION IF PROPER FLEX DUCT BEND RADIUS CAN'T BE ACHIEVED. 5. LOCATE FILTER AT BASE OF AHU-3. NO FILTERS IN RETURN GRILLS. KEYNOTES: OI 4"0 DRYER EXHAUST WITH WALL CAP. 20 MS-1 INDOOR UNIT INSTALLED ON GROUND VERTICALLY WITH RETURN LOW THRU WALL AS INDICATED. 3O COORDINATE EXACT CU LOCATION IN FIELD. ® PROVIDE 12NIT TRANSFER LOUVER LOW IN DOOR. OPROVIDE DEHUMIDIFIER IN CRAWL SPACE. COORDINATE REQUIREMENTS AND TYPE WITH THE OWNER 0 z 0 w w a 0 I Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 0) F rn U p rn W M U m Q d Q O Q W O 0 J L 3 Z w w < � cn a J � U W O z O ra w z 0 w Q oa w z o oQ o Q zz ~ W w� O c� v1 o F- W O 'Z x U w p a '�r EL a ran to Q o_ ENGINEER SEAL 82 ,ems 0 R +p:•:��` Eric J. Svoboda, PE P.E. No. 60982 I SHEET TITLE I HVAC PLAN I IJJVC `1 C: 06-12-2015 DRAWN: EJS APPROVED: EJS L DRAWING NUMBER I SHEET 3 OF 5 15020-02 a Y V a' O H\/,4C FL/4N 2ND FLOOR SCALE 1/8" = 1'-0° GENERAL NOTES: I. ROUTE REFRIGERANT LINES FROM AHU-4 UP ABOVE CEILING, THEN DOWN B THRU EXTERIOR WALL TO CU. 2. ROUTE 11 CONDENSATE DRAIN FROM AHU-3 BELOW FLOOR THEN DOWN 13, THRU EXTERIOR WALL. TERMINATE ABOVE GROUND IN LANDSCAPE AREA.000RDINATE EXACT AIR DEVICE LOCATIONS WITH LIGHTING LAYOUT. 3. PROVIDE PLENUM BOX ABOVE AIR DEVICES FOR SIDE CONNECTION IF PROPER FLEX DUCT BEND RADIUS CAN'T BE ACHIEVED. 4. LOCATE FILTER AT BASE OF AHU-4. NO FILTERS IN RETURN GRILLS. KEY NOTES: ID 40e DRYER EXHAUST WITH WALL CAP. 2O RANGE HOOD EXHAUST THRU WALL TO ALUMINUM HOOD WITH SCREEN. 3O RECIRCULATING RANGE HOOD. w Q a a z Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No, 28173 315 South 7th Street Fort Pierce. FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 Lo rn o rn M m Q R Z a Cr Q W O 0 o LL a w � z w<_ vi a J 0 H U 0.1 N Tn F-i I--d I --I Q Q W z 0) W m Q o a M f� W Z p O Q: Q U W 0 o zz W LL O > F- X� W y U a c� C) O O m M G d " a ro a ENGINEER SEAL � J SVQ �. STATELLOF ��t s CLlAl` % Eric J. Svoboda, PE P.E. No. 60982 TIFOE nom ' xue M THE ra is w m RESRRlS MUSEEp N]I-tE ARE Rw P OEY M 11E SPECOIC PIFPOSE I!ID [1@W 6 Mi PEACE nIGPIDt1NG, RE. FIR WRdI THESE maxLRrs 10 VES PRPPARE0. REUSE Ot RIPRO'ER AELIANf.E M nTIaW vRmLA aull®nnnm um A TATRN V NW PIDaZ EiGRFniaEu 1NC. SNALL BE VWOAO Man, TR THE Sz CRPYRIORm2P15, POW PIERCE DQEEFM M ALL MENTS RESERVER SHEET TITLE HVAC PLAN ISSUE DATE: 08-12-2015 DRAWN: EJS APPROVED: EJ DRAWING'S ER M-2.3 SHEET 4 OF 5 15020-02 1 1/2' STRAPS TO STRUCTURE STAINLESS STEEL BAND INSULATED FLEX DUCT 3' SHAFT INSERT 1 1/2' INSULATION RADIUS NOT LESS THAN ly 1 1/2'x DUCT DIA. BRANCH DUCT RETURN AIR DUCT - SEE PLAN FOR SIZE 773' SHAFT INSERT SUPPLY AIR DUCT - SEE PLAN FOR SIZE PROVIDE BUTTERFLY DAMPER STAINLESS STEEL BAND TRANSITION TO SUIT MFG. OPENING OPERATOR ON 1 1/Y STAND-OFF TO ALLOW INSULATE BELLS FOR INSULATION USE ROUND SHEET METAL DUCT HERE TO LIMIT FLEX DUCT TO 10'-0' IN LENGTH 11 CEILING 6'SADDLE CEILING DIFFUSER FLEX (TYP•) DIRECTION OF AIR FLOW BRANCH DUCT TAKE -OFF FITTING SECURE FLEX DUCT TO TAKE -OFF FITTING WITH STAINLESS STEEL SCREW DRIVER OPERATED BAND FLEXIBLE DUCT I STRAPI DAMPER SADDLE NOTE: USE BORDER TYPE 1 WHERE IN HARD CLGS. - BORDER TYPE C WHEN EXPOSED 1 1/2' INSULATION PROVIDE GASKET BETWEEN TAKE OFF FITTING AND BRANCH DUCT. A FLEX DUCT CONNECTION DETAILS TWX VALVE MOISTURE SIGHT GLASS 1. PROVIDE ACCUMULATOR IF DEVELOPED LENGTH IS GREATER THAN 50' 2. PROVIDE REFRIGERANT PIPE SIZES RECOMMENDED BY MFG. 3. SEE ALSO REFRIGERANT SYSTEM NOTES CHARGE VALVE W/CAP IF NOT PROVIDED WITH UNIT CONDENSING UNIT SEE DETAIL & SCHEDULE SENSING BULB — WITH REPLACEABLE FILTER/DRYER CORE CEILING DIFFUSER. INSULATE BELLS. SEE HVAC FLOOR PLAN FOR LOCATION OF DIFFUSER. CEILING NOTE: USE BORDER TYPE 1 WHERE IN HARD CLGS. - BORDER TYPE C WHEN EXPOSED ANGLE VALVES ISOLATION VALVES (TYPICAL) BALL TYPE ISOLATION VALVES IF NOT PROVIDED WITH UNIT SCALE - SUCTION LINE LIQUID LINE UP -FLOW AIR HANDLING UNIT - SEE SCHEDULE C.D. TRAP J FLOOR PLENUM SUPPORT BASE - 18' HIGH CONSTRUCT OF 18 GA. GALV. SHEET METAL WITH OPENING IN TOP & SIDE TER WALL DUCT SUPPORT PROVIDE EMERGENCY OVERFLOW SENSOR WATER GARD PRIMARY PAN SENSOR #401475B OR SECONDARY DRAIN HOLE SENSOR 1401490B WITH ALARM. WATER GARD, INC. 2211 CEDAR GAP, HOUSTON, TX 77072 PH 888-652-9800) * PLACE AIR HANDLING UNIT IN THE ROOM SO THAT SERVICE TO THE UNIT & FILTER REPLACEMENT CAN BE ACCOMPLISHED. B I VERTICAL AHU DETAIL AHU I & 2 THREADED CAP WITH Y2"O HOLE DRILLED IN TOP, HAND TIGHTENED. SLOPE TO DRAIN THREADED CAP, HAND TIGHTENED AIR HANDLER UNIT DRAIN PAN CASING SLEEVE -UNION NOTE: 1. FILL TRAP MANUALLY ON INITIAL START-UP. 2. PIPE SIZE SHALL NOT BE LESS THAN DRAIN PAN CONNECTION SIZE. 3. A = 12 TIMES FAN SUCTION S.P. B = %" PLUS FAN DISCHARGE S.P. 4. ALL CONDENSATE PIPING TO BE PVC. 5. INSULATE ALL DRAIN LINES WITH )z" ARMAFLEX WALL R.G. DUCT SUPPOR, TYPICAL AIR COOLED CONDENSING UNIT. DO NOT LOCATE UNIT WHERE THE UPBLAST WILL STRIKE ANY OVERHANG. LOCATE UNIT MINIMUM OF 2'-0' FROM BUILDING EXTERIOR WALL ANCHOR UNIT TO PAD WITH MIN. 1/4' DIA.— EXPANSION BOLTS 0 1 1/2' EMBEDMENT DEPTH & NEOPRENE PAD. (TYPICAL FOR 4) SUCTION & LIQUID REFRIGERANT LINES RUN REFRIGERANT LINES SHORTEST - FLOOR DISTANCE TO BLDG. EXTERIOR WALL. SEE PLANS FOR CONTINUATION. PROVIDE EMERGENCY OVERFLOW SENSOR WATER GARD PRIMARY PAN SENSOR #401475B OR SECONDARY DRAIN HOLE SENSOR 1401490B WITH ALARM. WATER GARD, INC. 2211 CEDAR GAP, HOUSTON, TX 77072 PH 888-652-9800) C VERTICAL CONCEALED UNIT DETAIL MS- I INDOOR SCALE _ (N T.S J SCALE SECURE TO STRUCTURE ABOVE AS RECOMMENDED BY SMACN�j 1 20 GA GALV. METAL STRAP `SHEET METAL SCREW, RIVET OR BOLT TO BOTH SIDES OF DUCT. TYPE 'A' TYPICAL RECTANGULAR DUCT BAND J IVIL DILL AS HANGER STRAP GER AD RATED 3TENEIR, 36" DIA. MAX TYPICAL ROUND DUCT DUCTSCHEDULE DUCT DIMENSIONS TYPE INCHES HANGER UP TO 18 A 19 TO 30 A/B 30 TO 60 B NOTE: 8'-0" MAX HANGER SPACING SECURE TO STRUCTURE ABOVE AS RECOMMENDED BY SMACNA 11ANGER ROD SIZEE Y' i TYPE'B' IvX1Nt'X GALVANIZED ANGLE HANGER RODS, WIRES OR STRAPS BAND ONE HALF —ROUND MAY BE USED IF DUCT SHAPE IS MAINTAINED PAD TO BE 4' LARGER ALL AROUND THAN UNIT, FURNISHED WITH 14 REBARS AT 6' O.C. BOTH WAYS 4„ a < < Y n <. 8' THICK CONCRETE PAD. 4' ABOVE GRADE AND 4' BELOW GRADE MIN. 3000 PSI D AIR COOLED CONDENSING UNIT DETAIL 3/8" DIA. THREADED STEEL HANGER ROD T SEE PLAN FOR EXHAUST DUCT CONTINUATION AND TERMINATION DUCT SLEEVES EXHAUST DUCT FLEX. CONNECTION TO EXHAUST FAN CABINET FAN UPPER ATTACHMENTS IN ACCORDANCE WITH SMACNA DETAILS RUBBER -IN -SHEAR VIBRATION ELIMINATORS (TYPICAL FOR ALL 4 HANGER RODS) CEILING EXHAUST FAN CEILING GRILLE Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 Lo m U d m Q m Q 0 Z� aLd =(N.T.S) O C) O U _j O z 3 w a w z to U O 1 N En z 0 H �1 Q W z 0) W 0) It Q a " W U% z = 0 :�i Q W rx O Fr w o zz U W O J LJJ U d U 0O o Ir O IL IL a- ti IMn ENGINEER SEAL ?? S E� F1 5'.W Eric J. Svoboda, PE P.E. No. 60982 TIESE ROELAENIS, &M VERI THE EAEEPTS ANR OR RESIGNS PREMTED IEfER! ORE RRQEER Q Y nR TIE SPECIFIC PLRPMSE AN➢ CLIENT 6 NIT PMCE ENGREERRG, IRE, U WHO TEY WERE FRETAREA REI&E ER RPN�LR REJU ON TNSE NLEMS VfiNR W MEN ILT UIT�! AN➢ A ATM V FORT PN.%E ENGNEERING, RIG SHOL. BE WaffliT LM UTY TO THE SAME EEPYRRM 0GM, W PIIACE FRGRE ]K M ILL RIGHTS RESERVER. SHEET TITLE MECHANICAL DETAILS IJJVG VHIG: 06-12-2015 DRAWN: EJS ' %N APPROVED: EJOIZ *. C\�> T)))) E I REFRIGERANT PIPING SCHEMATIC F I CONDENSATE DRAIN TRAP DETAIL G DUCT SUPPORT DETAILS SCALE=(MMS) H CEILING CABINET EXHAUST FAN DETAIL EET 5 OF 5 15020-02 PLUMBING SYMBOLS THERMOMETER POSITIONED °(O BE READ FROM FLOOR (RANGE 0-200 A HOT WATER SUPPLY EXPANSION TANK �— COLD WATER SUPPLY ISOLATION GATE �- -Pw-PIPE UNION (TYP) VALVE (TYP) P8T RELIEF VALVE (SETTING BY MFR. OF HEATER) FULL SIZE OF VALVE ELECTRIC WATER OUTLET HEATER - ROUTE TEMP. AND PRESS. VALVE OUTLET TO 6" ABOVE PAN - ROUTE 3/4" PAN DRAIN TO EXTERIOR FLOOR MOUNTED ELECTRIC WATER HEATER DETAIL N.T.S. 3110 FLOOR DRAIN FLOOR DRAIN WITH 1 RAP GUARD INSERT N.T.S. 2" STAND PIPE � 12" x 12" ACCESS PANEL IAIAC1-1INIC l,A A(`I-11 NIC unr)V-1IID nFTA11 PLUMBING FIXTURE SCHEDULE CODE DESCRIPTION HW CW WASTE VENT TRAP REMARKS WATER CLOSET, FLOOR MOUNTED, WC-1 1/2" 3" 2" INT SELECTED BY OWNER. — LAVATORY, COUNTERTOP, WITH FAUCETS, L-1 1/2" 1/2" 2" 1 1/4" 1 1/4" SELECTED BY OWNER. KITCHEN SINK, COUNTERTOP, 2 S-1 COMPARTMENT WITH FAUCET, SELECTED 1/2" 1/2" 2" 1 1/2" 1 1/2" BY OWNER. LAUNDRY / UTILITY SINK, COUNTERTOP, S 2 1/2" 1/2" 2" 1 1/2" 1 1/2" WITH FAUCET, SELECTED BY OWNER. SINK, COUNTERTOP, WITH FAUCET, S-3 1/2" 1/2" 2" 11/2" 11/2" SELECTED BY OWNER. SHOWER, WITH SHOWER HEAD & VALVE, ADJ. TEMP. LIMITSTOP, PRESSURE SH-1 1/2" 112" 2" 11/2" 2" BALANCING, 2" TRAP WITH GRID DRAIN, SELECTED BY OWNER. BATH, TUB FAUCET WITH VALVE, 2" TRAP B-1 WITH CHROME LIFT & DRAIN BATH WASTE. 1/2" 1/2" 2" 1 1/2" 2" SELECTED BY OWNER PLUMBING EQUIPMENT SCHEDULE CODE I DESCRIPTION REMARKS EXTERIOR CLEAN OUT, 2-WAY, ADJUSTABLE SET IN 12" X 12" X4" CO-1 TOP, INTERNAL CLOSURE PLUG, HEAVY DUTY CONCRETE COVER PLATE. CO-2 WALL CLEAN OUT PLUG WITH CHROME PLATED BRASS COVER PLATE. ELECTRIC WATER HEATER, A.O. SMITH DEN 52, PROVIDE EXPANSION TANK EWH-1 50 GAL, 4.5KW, ASME CONSTRUCTION, T&P RELIEF VALVE, 230V, 1 PHASE PER CODE. SET AT 110 DEG, UTILITY VALVE BOX FOR WASHER, 3/4" HOSE VB-1 THREAD, H&CW VALVES, 2" DRAIN CONNECTION. ICE MAKER OUTLET BOX WITH 1/4 TURN VALVE VB-2 AND MOUNTED WATER HAMMER ARRESTOR. FLOOR DRAIN, JOSAM SERIES 30000A, C.I. BODY, POLISHED BRONZE STRAINER W/ PROVIDE WITH TRAP GUARD INSERT BY PROSET. TRAP FD-1 EXTENDED RIM, INTEGRAL TRAP, WITH TRAP PRIMER TO BE CONNECTED GUARD INSERT & PRIMER CONNECTION. TO NEAREST SINK. HOSE BIBB, ALL BRASS, 3/4" HOSE PROVIDE SHUT-OFF TO HB-1 CONNECTION, VACUUM BREAKER, WHEEL EACH HOSE BIBB PER HANDLE STOP. I CODE. SYMBOLS DESCRIPTION - — - COLD WATER (CW) -- HOT WATER (HW) SEWER (S) VENT LINE (V) — HWR RECIR. HOT WATER CD CONDENSATE DRAIN X EXISTING PIPE ® CONNECT TO EXISTING -SD- STORM DRAIN (SD) P PUMP VTR VENT THRU ROOF WC WATER CLOSET UR URINAL HL HAND LAVATORY L-(No) LAVATORY HB HOSE BIBB SS SERVICE SINK DF DRINKING FOUNTAIN EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER GWH GAS WATER HEATER SH SHOWER HS HAND SINK FD FLOOR DRAIN RD F200F DRAIN —0o- GATE VALVE -�� GLOBE VALVE CHECK VALVE BACK FLOW PREVENTER VALVE IN YARD BOX (TYPE AS NOTED) PRESURE RELEIF VALVE (RV) -�M - WATER METER -O ELBOW- UP -E) RISE OR DROP -per CONCENTRIC REDUCER -p- DIRECTION OF FLOW C.04 CLEAN OUT (RISER) —C.O. _-o- C.O. LEAN OUT C III WALL CLEAN OUT -� PLUGGED PIPE SHOWER HEAD -{4�- PUMP W/FLOW DIRECTION FLOW SWITCH PRESSURE SWITCH TA,B,C,D WATER HAMMER ARRESTER WITH P.D.I. SIZE I. PLUMBING CONTRACTOR IS TO FURNISH AND INSTALL ALL PLUMBING FIXTURES COMPLETE AS LISTED IN "PLUMBING FIXTURE SCHEDULE". 2. PLUMBING CONTRACTOR MAY USE SCHEDULE 40 OR 80 TYPE I, GRADE I, POLYVINYL CHLORIDE PIPE FOR ALL SOIL, WASTE AND VENT PIPING WHERE PERMITTED BY LOCAL CODES. WHERE PVC PIPING IS NOT PERMITTED BY LOCAL CODES, USE STANDARD WEIGHT CAST IRON PIPING. ALL PIPING ABOVE GRADE MAY HAVE HUBLESS FITTINGS. PLASTIC PIPING SHALL NOT BE USED IN A RETURN AIR PLENUM. COORDINATE THIS REQUIREMENT WITH H.V.A.C. CONTRACTOR. 3. PROVIDE SHUT-OFF GATE VALVES ON ALL EQUIPMENT a HOSE BIBBS, 8 STOP COCKS IN HOT AND COLD WATER PIPING TO ALL PLUMBING FIXTURES. 4. ALL WATER PIPING BELOW GRADE SHALL BE TYPE "L" SOFT TEMPERED COPPER AND ALL WATER PIPING ABOVE GRADE SHALL BE TYPE "L" HARD TEMPERED COPPER. 5. INSTALL I" FOAM RUBBER INSULATION ON ALL HOT WATER PIPING ABOVE GRADE. ALL JOINTS IN INSULATION ARE TO BE TAPED. 6. ELEVATION OF ALL FLOOR DRAINS SHALL BE HELD 1/2" BELOW FINISH FLOOR TILE. 7. ALL MATERIAL AND INSTALLATIONS SHALL BE IN ACCORDANCE WITH ALL LOCAL AND STATE PLUMBING AND MECHANICAL CODES, INCLUDING THE STANDARD BUILDING, PLUMBING AND MECHANICAL CODES, NEPA, ASME, ASHRAE, ASA AND AGA. 8. THE SANITARY SYSTEM INCLUDES CONNECTION TO FIXTURES, RUNNING OF SOIL AND WASTE LINE AND SOIL AND VENT SANITARY SEWER SYSTEM AND/OR SEPTIC TANKS AND DRAIN FIELDS AND ALL ITEMS AS SHOWN ON DRAWINGS. VENT STACKS SHALL EXTEND THROUGH ROOF WITH LEAD FLASHING. 9. THE DOMESTIC WATER SYSTEM INCLUDES CONNECTIONS TO THE DESIGNED SYSTEM, CONTROL VALVES AND PIPING TO PLUMBING FIXTURES, INCLUDING CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS. 10. PIPE INSTALLATIONS AND MATERIALS SHALL BE AS REQUIRED TO MAINTAIN FIRE RATINGS WHERE REQUIRED BETWEEN FLOORS AND/OR BETWEEN UNITS. II. ARRESTERS SHALL BE INSTALLED WHERE NECESSARY TO PREVENT WATER HAMMER. 12. COPPER PIPING WHERE USED SHALL NOT CONTACT DISSIMILAR METALS OR MASONRY. PROVIDE ISOLATING BUSHINGS WHEN CONNECTING TO ANY DISSIMILAR METALS. 13. PLUMBING CONTRACTOR SHALL COORDINATE WITH ARCHITECT FOR DETAILED DIMENSIONS AND LOCATIONS OF ALL FIXTURES AND EQUIPMENT AND FOR ANY CHANGES IN LAYOUT. 14. PLUMBING CONTRACTOR SHALL MAKE ALL TEST AND ADJUST- MENTS AS REQUIRED, UPON COMPLETION OF WORK AND PRIOR TO FINAL ACCEPTANCE BY OWNER. 15. AFTER COMPLETION OF THIS WORK, THE CONTRACTOR SHALL OBTAIN A CERTIFICATE OF FINAL INSPECTION AND APPROVAL FROM ALL AUTHORITY'S HAVING JURISDICTION. 16. ALL WORKMANSHIP, MATERIALS AND APPARATUS UNDER THIS CONTRACT SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY THE OWNER. SHEET PLUMBING DRAWING INDEX DESCRIPTION ISSUED P-1 PLUMBING LEGEND, NOTES, SCHEDULES a DETAILS YES P-2.1 PLUMBING EXISTING / DEMO PLAN YES P-2.2 PLUMBING IST FLOOR PLAN YES P-2.3 PLUMBING 2ND FLOOR PLAN YES P-3 PLUMBING WASTE -VENT a WATER RISERS YES a U 0 z O w Q 0 z Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone:772 672-4636 Fax:772 672-4637 Ln ti m u o v p J m Q Z o Q 0_ W O Q°o o F 3 Lei w P4 a O U = EU In z O N� Q W Z O rn Q a a M -ti 0 Q W z o W O E Q w O zz o WU_ O J -X �� �j O d LJ U O `� O � n a ENGINEER SEAL SVO&\\i111111//�/ 1\! ` O. STATE 0P4t` r T y��•�< O B IiiQ=.tea=�� tAl Eric J. Svoboda, PE P.E. No. 60982 THESE RQLIENfS, ALMG VnH TIE LMCEVIS AND M KSIGNS MSEME" IEAEIN AK INFnIDFR REY FOR TIE SPEEIFS PL"PME MID ELRNT M Nn PIERCE 9X6IIEERM INC. FM MM DU VEK FREP REUSE M IM R WUAN M T SAn"ENTS Vnw Warm A ZATIM MID A ATRN GY FMT PRISE E"GREE3RNG, M SHALL K VnIOJ! LMUn TO TIE S SMYR"MOM, FMT PIERCE EM,IIEERING, INC. ALL RIGHTS RESERVER SHEET TITLE PLUMBING LEGEND, NOTES, SCHEDULES & DETAILS ISSUE DATE: 06-12-2015 DRAWN: EJS APPROVED: EJS I DRAWING NUMBER I NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. SHEET I OF 5 15020-02 a a Y U EXISTING WELL 0 FLUMBING EXISTING/DEMO FL/4N IST FLOCR SCALE 1/8" = I`0" ACTIVE WASTE LINE ACTIVE WATER BRANCH CUT a CAP ABANDONED CUT a CAP ABANDONED CONNECTION CONNECTION 2FT OR IMMEDIATELY AT ACTIVE 2FT OR LESS LESS DEVELOPED BRANCH CONNECTION xs� LENGTH FROM ACTIVE DEVELOPED LENGTH TAKE -OFF TO PREVENT WASTE LINE TO PREVENT DEAD -LEG. DEAD-END. UJ�STF UJ�4TER DEl10 DETAIL „FLUMBIN(__ EXISTING ;/DE>10 FL/4N 2ND FLOOR SCALE 1/8" = 1'-0" NTS GENERAL NOTES: I. EXISTING PLUMBING FIXTURES TO REMAIN UNLESS NOTED OTHERWISE. 2. CUT a CAP WASTE a WATER CONNECTIONS AS NECESSARY FOR FIXTURES BEING REMOVED. 3. MAINTAIN WASTE 8 WATER CONNECTIONS FOR EXISTING REMAINING FIXTURES AS NECESSARY. KEY NOTES: lO EXISTING SINK TO BE REMOVED. 20 EXISTING WASHING MACHINE VALVE BOX TO BE REMOVED. 3O EXISTING 65 GALLON, 4.5 KW ELECTRIC WATER HEATER TO BE REMOVED / RELOCATED. EXISTING MAIN HOT WATER CONNECTION TO HOUSE FROM EXISTING HEATER LOCATION TO BE MAINTAINED / EXTENDED AS NECESSARY TO CONTINUE HOT WATER SERVICE TO EXISTING HOUSE. ® EXISTING WATER SOFTENER SYSTEM TO BE REMOVED / RELOCATED. 5O EXISTING WELL PUMP & PRESSURE TANK IN CRAWL SPACE BELOW FLOOR TO BE REMOVED / RELOCATED. LINES SHALL BE EXTENDED FROM WELL AT THIS POINT TO NEW LOCATION AS NECESSARY. © EXISTING MAIN WATER CONNECTION TO HOUSE FROM SOFTENER TO BE MAINTAINED / EXTENDED AS NECESSARY TO CONTINUE SERVICE TO EXISTING HOUSE. ® EXISTING MAIN WASTE EXIT FROM STRUCTURE TO BE RELOCATED - INTERCEPT B ADJUST DIRECTION OF WASTE LINE RUNNING BELOW FLOOR IN CRAWL SPACE AS NECESSARY, SEE SHEET P-2.2 FOR NEW PROPOSED LOCATION TO RUN TO NEW DRAIN FIELD. VERIFY INVERT ELEVATION FOR PROPER SLOPING. 80 EXISTING HOSE BIB TO BE REMOVED. z z 0 w a 0 a z Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 H U p o J M U m p z a O Ca U J °0 3 w z Ld n a J O F U P] N In z 0 Q w zD1 w z U Lj Q -" W Z O V) LD U o J I— 1-) oP0 m o a it � o W O } H 3-U 0 0 � m a a ro a_ ENGINEER SEAL ww,l411f111jols, pew�sS o V , & °O°s 82 it �'. STATE OF IJJi A,< O IDP,�,ww Eric J. Svoboda, PE P.E. No. 60982 IIESE WLIBENTS, AIBlG WIN TIE CMCEPTS MID M BESM PIESDfIEB F EB ARE BIE1100) BEY HAR TIE SPECIFIC Pf?RBE ANB ELIPM 6 EMT PIERCE ENLREERB6, M FOR WHICH 1HEY WERE PREPARED. REW Ot 1MRBPER REl IMSE IN THESE AEIKNTS VI11WI WRITTEN NETHURRATIBN AND ABMTATIN BY EMT MERLE EMINEERM, INC. WL BE VITW L1011.1 Y ill TIE SOME. COPYYBWTOM5, Fun PIERCE ENBBEERM INE. ML RIGHTS RESERVER. PLUMBING DEMO PLAN ISSUE DATE: 06-12-2015 1 DRAWN: EJS APPROVED: EJS I DRAWING NUMBER I I SHEET 2 OF 5 1 15020-02 Y U K EXISTING WELL O fi�LUM II�C� FL,4N iST FLOOF, SCALE I/8" = I'-O" GGflI 3-1 GENERAL NOTES: I. INSTALL NEW FIXTURES AS INDICATED. 2. FIELD VERIFY EXISTING CONNECTIONS / INVERT WASTE ELEVATIONS PRIOR TO TIE IN OF NEW LINES. 3. ROUTE 1" CONDENSATE DRAIN FROM AHU-3 IN MECHANICAL ROOM 116 BELOW FLOOR TO EXTERIOR. COORDINATE WITH MECHANICAL CONTRACTOR. KEY NOTES: lO RELOCATE EXISTING WELL PUMP / PRESSURE TANK TO EXTERIOR LOCATION AS INDICATED. EXTEND WELL LINE FROM PREVIOUS LOCATION AS NECESSARY. O ROUTE In LINE FROM WELL PUMP UP ABOVE CEILING TO NEW WHOLE HOUSE SOFTENER SYSTEM AS INDICATED. 3O RELOCATE EXISTING 65 GALLON, 4.5 KW WATER HEATER TO NEW LOCATION AS INDICATED. ROUTE 3/4" PAN DRAIN THRU EXTERIOR WALL & TERMINATE ABOVEGROUND. 4O ROUTE In CW LINE FROM SOFTENER UP ABOVE CEILING TO TIE BACK INTO EXISTING HOUSE MAIN SUPPLY POINT AS INDICATED. 0 ROUTE 3/4" HW FROM HEATER UP ABOVE CEILING TO TIE BACK INTO EXISTING HOUSE MAIN SUPPLY POINT AS INDICATED. © LOCATE & TIE INTO EXISTING HOUSE MAIN CW SUPPLY POINT AS NECESSARY. 7O LOCATE & TIE INTO EXISTING HOUSE MAIN HW SUPPLY POINT AS NECESSARY. 8O ROUTE in CW LINE FROM SOFTENER UP ABOVE CEILING TO RUN BELOW WALKWAY TO SERVE NEW ADDITION AS INDICATED. 9O SEE SHEET P-2.3 FOR CONTINUATION OF WATER LINE BELOW FLOOR ABOVE, 10 1/2" HBCW DOWN FROM ABOVE. II 3/4" CW DOWN TO EWH-I / 3/4" HW UP FROM EWH-I. 12 2" VENT THRU ROOF. 13 3" WASTE DOWN FROM ABOVE. 14 ROUTE NEW WASTE LINE FROM EXISTING MAIN WASTE LOCATION IN CRAWL SPACE AS INDICATED. 15 4" WASTE TO NEW PROPOSED DRAIN FIELD. COORDINATE EXACT ROUTING IN FIELD. I6 ROUTE 3/4" PAN DRAIN THRU EXTERIOR WALL 8 TERMINATE ABOVE GROUND. 17 PROVIDE DRY WELL FOR SOFTENER BACKWASH DISCHARGE CONNECTION. a 0 I Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 J Z C E� Q W z 0) 0 w o� w Q z U U w Z C v) z z 0 U 0 J H o w o w Q� ~ a� 00 Ir 0 � r� r) a 0- ti tL M a - ENGINEER SEAL ' SvQ& \G E �O®ems ".0,,N% A, P etro: 11"Plo e0 N A' -E 0" Eric J. Svoboda, PE P.E. No. 60982 I SHEET TITLE I PLUMBING FLOOR PLAN ISSUE DATE: 06-12-2015 I DRAWN: EJS APPROVED: EJS I DRAWING NUMBER I SHEET 3 OF 5 15020-02 Y U K O r PLUMBIN G FLAN 2ND FLOOR SCALE 1/8" = 1'-0" I I I I I I _J GENERAL NOTES: I. INSTALL NEW FIXTURES AS INDICATED. 2. FIELD VERIFY EXISTING CONNECTIONS / INVERT WASTE ELEVATIONS PRIOR TO TIE IN OF NEW LINES. KEY NOTES: 01 IN CW CONTINUED BELOW FLOOR FROM BELOW RAISED WALKWAY. 20 2 1/2' VENT THRU ROOF. 0 3" WASTE DOWN. ® 1/2' HBCW DOWN TO IST FLOOR. 50 3/4' CW DOWN TO EWH-I / 3/4' HW UP FROM EWH-I ON IST FLOOR. © PROVIDE R/O WATER SYSTEM BELOW SINK. COORDINATE WITH THE OWNER. a 0 tort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No.28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax:772 672-4637 O O � J M m Q Z Q O Ca U J c) LL W ~ w z to a J O W O Co O H w z 0) 0) W Q z U LLJ w Q -" Z O C/] Z z O U O OLd It oK) M o a o � w w O w ~ a O O O of ro Q d ti 0- toa ENGINEER SEAL P°aInuf poll*..ONG S V ^ O �'1s ro o0 ®2 4�f* :0 •. STAT OF :�` .�s'.c� 0 R l O P Ca`,` s ° Eric J. Svobodo, PE P.E. No. 60982 I SHEET TITLE I PLUMBING FLOOR PLAN I lOJUC URIC 06-12-2015 1 DRAWN: EJS APPROVED: EJS I DRAWING NUMBER I I '%&ET 4 OF 5 1 I