HomeMy WebLinkAboutEVALUATION REPORT ROOF UNDERLAYMENTSI
: 'SCANNED
BY EXTERIOR RESEARCH & DESIGN, LLC.
�Lucie ftnbl Certificate of Authorization #9503
'j RI I(TY ERD 353 CHRISTIAN STREET, UNIT #i13
! t`► 1 Vt I I OXFORD, CT 06478
ST•jtO� COUNTY BUILDI DIVISION (203) 262-9245
EVALUATION REPORT REVIEWED FOR COMPLIAN
Polyglass USA, Inc. DATE Evaluation Report P12060.02.09-R23
150 Lon Drive FL5259-R27
Y PLANS AN PE IT MU KEPT ON JOB
Fernley, NV 98408 SITE OR NO INSPECTIO S) WILL BE MADE Date of Issuance: 02/24/2009
(570) 384-1230 i Revision 23: 09/14/2017
SCOPE:
This Evaluation Report is issued under Rule 61G
construction materials in the State of Florida. The c
for use of the product under the Florida Building
described herein have been evaluated for complia
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the
CONTINUED COMPLIANCE: This Evaluation Report is
Quality Assurance documentation changes, or pro,
Evaluation Report by the named client constitutes
referenced Quality Assurance documentation cha
relative to updated Code requirements with each (
ADVERTISEMENT: The Evaluation Report number 1
advertising literature. If any portion of the Evaluat
9 and the applicable rules and regulations governing the use of
imentation submitted has been reviewed by Robert Nieminen, P.E.
de and Florida Building Code, Residential Volume. The products
with the 6`h Edition (2017) Florida Building Code sections noted
the Accredited Quality Assurance Agency noted herein.
id until such time as the named product(s) changes, the referenced
)ns of the Code that relate to the product change. Acceptance of this
•eement to notify Robert Nieminen, P.E. if the product changes or the
-s. Trinity IERD requires a complete review of this Evaluation Report
e Cycle.
:eded by the words "TrinitylERD Evaluated" may be displayed in
Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through
Prepared by:
Robert J.M. Nleminen, P.E.
Florida Registration No. 59166, Florida DC4ANE1983
The facsimile seal appearing was authorized by Robert Nleminen,
P.E. on 09/14/2017. This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity) ERD does not have, nor does it intend to acl uire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluate .
3. Robert Nieminen, P.E. does not have nor will acquire a financial interest in any company manufacturing or distg products for
which the evaluation reports are being issued. RIO
4. Robert Nleminen, P.E. does not have, nor will acquire, a financial interest in any other entity invoAVd4�tla�'Sprocess of the
product. 0
5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are I�0 ����� C'��®Ford for any
e unless retained
project on which this Evaluation Report, or previous versions thereof, is/was us �� f*
specifically for that purpose. pQt� `�t�OgPr`' pp�►�
+ J 0011y
��O `tfy`y.Vlo
J � .
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE: _ ..
Product Category'. ;roofing.._
Sub -Category: Underlayment
Compliance Statement: Roof Underlay'me'nts; as produced. by Polyglass USA;,.Inc:; 17have demonstrated compliance with the
pro .
following sections of the 5`h Edition (2014)''Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.3 / 1507.1.1
Physical Properties
ASTM D226
2009
1507.2A / 1507.1.1,1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
1507.11.2
Physical Properties
ASTM D6164
2011
1507.21.2
Physical Properties
ASTM D6222
2011
1523.6.5.2.1
Physical Properties
TAS 103
1995
TAS 110
Accelerated Weathering
TAS 110
2000
3. REFERENCES:
Eniitlf
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRIO1111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2009
PRI (TST 5878)
Physical Properties
PUSA-076-02=01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX34E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST �0449)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049):;'� :` ;� .,
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST'6049.) :;,;, ,'y = ;' ;
Physical Properties
P13450.08.09
68/13/2009
,
`'' ' '' =o -1
ERD(TST6049 •;,:•;...�•,!,..,• ,
'r; . Wind Uplift
P30540.11.09-R1
21/30/2009
ERD ST,6049 1 9
(T
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049), " "<<r) r ` %:,, , ` :,Ly, V •. Wind Uplift
P13030.11.09-2
11/30/2009
ERD (TST 6049)Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049) %. j ; �' y ;� �,; %.'� Physical Properties
P33360.06.10
06/25/2010
ERD (TST 6049) - ' h' ., ''° Physical Properties
P33370.03.11
03/02/2011
ERD (TST 6049)
"'• Physical Propertles
P33370.04.11
04/26/2011
ERD (TST 6049)
�' Physical Properties `;
P37300.10.11
10/19/2011
Exterior Research and Design, LLC.
Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503
6'" EDITION (2017) FBC NON-HVHZ EVALUATION
FL5259-R27
Polyglass Roof Underlayments,
(570) 384-1230
Revision 23: 09/14/2017
Page 2 of 14
TRINITY II ERD
Ent! Examination Reference Date
ERD (TST 6049) Physical P ioperties P40390.08.12-1 08/06/2012
ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD (TST 6049) Physical Prloperties P45370.04.13 04/26/2013
ERD (TST 6049) Wind Uplift" P1738.02.07-R2 04/29/2013
ERD (TST 6049) Wind Uplift; 11757.04.01-1-R3 04/30/2013
ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD (TST 6049) Wind Uplifi1t P11751.05.03-R1 11/26/2013
ERD (TST 6049) Wind Upli4 P11781.11.03-Ri 11/26/2013
ERD (rST 6049) Physical P loperties P45270.05.14 05/12/2014
ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD (rST 6049) Physical Properties 6020.09.14-3 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD (TST 6049) Physical P loperties 6020.09.14-5 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD (tST 6049) Physical Properties P46520.10.14 10/03/2014.
ERD (17ST 6049) Physical Properties P44360.10.14 10/07/2014
ERD (TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD (TST 6049) Physical Pioperties PLYG-SC7550.03.15 03/24/2015
ERD (TST 6049) . Physical Properties P40390.04.15 04/03/2015
ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD (rST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD (rST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016
ERD (TST 6049) Wind Uplift PLYG-SC32025.10.16 10/12/2016
ERD (rST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016
ERD (TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ERD (TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017
ICC-ES (EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA PA Affidavit Mule -Hide Cross Ltg 03/01/2008
Polyglass USA Materials (Affidavit Polystick SA Compound 08/18/2011
UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 10/05/2018
4. PRODUCT DESCRIPTION:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBIS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass•APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets TAS 103.
4.2.2 Polystick IR-Xe is a nominal 60-mil thick (rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and TAS 103.
Exterior Research and Design, LLC. Evaluation Report P32060.02.09-R23
Certificate ofAuthorizotion #9503 6i" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (510) 384-1230 Revision 23: 09/14/2017
Page 3 of 14
TRINITY i ERb
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/mZ polyester
fabric surface; meets ASTM D1970 and TAS 103.
4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012.
4.2.7 Polystick Dual Pro' is a nominal 60-mil thick dual -layer, rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.8 Polystick Tile Pro' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
WX
ifPF On, : a-:,' �' PS' ` .s,• '�ti-:.b,.� 't .;.s "
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex 56 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System',' from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened the roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Unde"rlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. 1 If not listed, a request may be made, to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Deslgn,.LLC. Evaluation Report P32060.02.09-R23
certffl-te afAuthonroUon #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ7
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2011
Page 4 of 14
\.I TRINITY � ERD
5.5 Allowable Roof Covers:
"`'� �i �+� a�i� ,x x �
a
€ �ab` 'f,"`�i' "u ��,. Y<� � "f r
Asphalt Shingles Naill On Tile
�,k°'Y F✓ '�i" g
Yi .r°�
� Yak' C .o
.
Slate
Underiayment
Foam -On Tile
Metal
wood Shakes
& Shingles
Elastobase
Yes
Yes
(Base SheetlIn 2-ply system)
Yes
(Base Sheet In 2-ply system)
Yes
Yes
Yes
Elastobase P
Yes
(Base Sheetlin
iYes
2-ply system)
Yes
(Base Sheet In 2-ply system)
Yes
Yes
Yes
Polyglass G2 Base
No
(Base Sheetlin
'Yes
2-ply system)
Yes
(Base Sheet in 2-ply system)
No
No
No
Polyglass APP Base
No
(Base Sheetlin
Yes
2-ply system)
Yes
(Base Sheet In 2-ply system)
No
No
No
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
INo
No
No
Yes
Yes
Polystick TU P
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes (See 5.5.1)
Yes
No
No
Polystick Dual Pro
Yes
INo
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick MU-X
Yes
INo
No
Yes
Yes
Yes
Elastoflex S6 G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex S6 G FR
Yes
Yes
No
No
Yes
Yes
Elastoflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5.1)
_ No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
I es
Yes (See 5.5.1)
No
Yes
Yes
I
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
� rx..AB
mil `t' m�i�lFl
$ s t E a r '
Florida Product
.tea O,xINil��a.`,`
Adhesive
Approval
Underlayments
DAP Foam Touch 'n Seal StormBond Roof
Tile Adhesive
FL1450i6
Polystick TU Plus, Polystick TU Max
Dow TileBond'"
FL22525
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® AH-160
FL6332
Elastoflex G TU, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polyglass PolyLok Roof Tile Adhesive
FL17855
Polystick TU Plus or Polystick TU Max
2 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, LLC. I
IEvaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION F1.5259-1127
Polyglass Roof Underlayments; (570) 384-1230 " Revision 23: 09/14/2017
Page 5 of 14
I
TRINITY I ERD
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM-D41 primed existing
plywood; .New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require' priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:.
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on the systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2612 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23
Certiftate oJAuthorization #9503 6r" EDITION 12017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments;1570) 384-2230 Revision 23: 09/14/2017
Page 6 of 14
5.6.4
address wind uplift resistance of all unc
forms part of the load -path. The fall(
addressed in FRSA/TRI April 2012 (04-12
result of testing for wind load resistanu
divided by 2 (the 2 to 1 margin of safety
12), Appendix A, Table 1A or FBC 1609 fo
#1 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to n
Primer: None
Underlayment: Polystick TU P, Polystick TU PI
Mule -Hide SA-APP Cap Sheet
#2 Maximum Design Pressure = -97.5 psf:
Deck: Min.15/32-inch plywood to n.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TU P
Mule -Hide SA=APP Cap Sheetl
1W ring shank nails through 3
#3 Maximum Design Pressure = -105 psf:
TRINITY l ERD
!ms in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
!rlayment systems beneath foam -on tile systems, where the underlayment
ving wind uplift limitations apply to underlayment systems that are not
and are used in foam -on tile applications. Maximum Design Pressure is the
based on allowable wind loads, and reflects the ultimate passing pressure
ier FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
determination of design wind loads.
project requirements to satisfaction of Authority Having Jurisdiction.
Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
. self -adhered.
project requirements to satisfaction of Authority Having Jurisdiction.
us, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
(FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
2 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
Deck: Min. 15/32-inch plywood to ' eet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Underlayment: Polystick TU P, Polystick TU P us, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and.
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within.the selvedge -edge side laps using 12 ga. x
1Y.." ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-135 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#5 Maximum Design Pressure= -315 psf:
Deck: Structural concrete to meet
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TU
Sheet and Mule -Hide SA-APF
#6 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex
#7 Maximum Design Pressure=-30.0 psf*:
Deck: Min. 15/32-inch OSB to meet
Base Sheet: Elastobase or Mule -Hide Nail
Fasteners: 11 ga. x 1.25-inch long x 1-ini
Spacing: 6-inch o.c. at the 3-inch wide
Underlayment: Polystick TU P, Polystick TU F
Mule -Hide SA-APP Cap Sheet
#8 Maximum Design Pressure = -37.5 nsf*:I
requirements to satisfaction of Authority Having Jurisdiction.
Ilus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Cap Sheet (FR), self -adhered. ,
requirements to satisfaction of Authority Having Jurisdiction.
G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
project requirements to satisfaction of Authority Having Jurisdiction.
Base (poly -film top surface)
:h head diameter round metal cap nails
side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
lus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
(FR), self -adhered.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1491ch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center -rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-1123
Certiflcate of Authorizatlon#.9503 If" EDITION (2017) FBC NON-HVH2 EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 7 of 14
TR1NrrY J ERD
#9 Maximum Design Pressure = -37.5 Dsf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#10 Maximum Design Pressure = -45 Dsf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt.
#11 Maximum Design Pressure = -45 Dsf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type 11 felt
Fasteners: it ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot
asphalt.
#12 Maximum Design Pressure=-45 Dsf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-Inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#13 Maximum Design Pressure = -52.5 Dsf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top, surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure = -52.5 Dsf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inchmide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#15 Maximum Design Pressure = -52.5 Dsf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#16 Maximum Design Pressure = -60 Dsf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spadng: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-1123
CertifcateofAuthorization#9503 eH EDITION (2017) FBC NON-HVH2 EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 8 of 14
'i
TRINITY ERb
#17 Maximum Design Pressure = -60 P!
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure = -67.5 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-i ch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure = -75 asf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass; PP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast414 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10•inch o.c. at the 4-inch wide side laps and 104nch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maximum Design Pressure = -90 asf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure = -90 W.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip oOMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex Sg G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure =-90 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#23 Maximum Design Pressure=-90 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, CMG Roofgrip #14 with
OMG Flat Bottom Plates (AcicuTrac), Trufast HD with Trufast 3-inch Insulation Plates or•Simplex.,MAXX Cap
Fasteners
Spacing: 9-inch o.c. at the 4-irich wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certftate ofAuthorizotion #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments;'(570) 384-1230 Revision 23.09/14/2017
Page 9 of 14
TRINITY i ERb
#24 Maximum Design Pressure = -97.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-Inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maximum Design Pressure = -105' psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#26 Maximum Design Pressure = -120 psf:
Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded to surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#27 Maximum Design Pressure = -120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of -45 psf.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than
180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set -tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. .
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-1123
Certificate oJAuthorization #9503 6rx EDITION (2017) FBC NON-HVHZ EVALUATION . FL5259-R27
Polyglass Roof Underlayrnents; (570) 384-1230 Revision 23: 09/14/2017•
Page 10 of 14
TRINITY ERD
5.9 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
1
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
4 ' t t i�i?A -i"i
� � � ` � . " °
191 . �. _ a x z. .�
�` .{*C&' £ �kk i i S
TABLE : ,S IPPA M �► 115�
v �
'b`, �•.�3%•a�' i..a�, d' i" '.
ISE l R1. � .�'
1, '-t� +F {'1jV, ( ^'g
e ? c
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
10-tile stack
7:12
Lugged
&tile stack (6 over 2)
6:12
Elastoflex S6 G or 56 G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS
Flat or Lugged
Prohibited without battens
N/A
Polystick Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
30-tile stack
6:12
Polystick TU P
Flat
6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
�� asl oid u)I'if at B' ...3tsta#�.:�. ,.v OWN62
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table
1507.1.1 for the type of prepared roof co ering to be installed.
Elastobase, Elastobase P or Mule -Hide N I it Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S6 G FR in hot asphalt or Poly)ex G or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide N 11 Base are limited to use as a mechanically attached base sheet in the "Two
Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2022 (04-12) Installation Manual.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
6T" EDITION (2017) FBC NON-HVHZ EVALUATION .
Polyglass Roof Underlayments; (570) 394-1230
Evaluation Report P12060.02.09-R23
FL52S9-R27
Revision 23: 09/14/2017
Page 11 of 14
�',l TRINITY I ERD
L 1 'I
.,.4.� Shale be installed
in comoliance ti�vitr the codifie., recuireman�s
d
t A T f. t i D Table1,007.1.1
for .,S � i4� D137C underfavmen. in FwC T® z
6.4.2
for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FIR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed
using the above noted fasteners -and spacing, in area marked "nail area, area para clavar" on the face of membrane.
The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 128 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
View of Ovelap Seam of Dual Pro and Tile Pro
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications (not allowed for Polystick Dual Pro, IR-Xe or Polystick MU X):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than .FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set the applications; refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
6.4.4 Two (2) Ply Underlavment Systems:
Polystick MTS followed by Polystick MTS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material.
This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-1123
Certijicote of Authorization #9503 67" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ7
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 12 of 14
F)o
TRINITY 11 ERD
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in the applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRl April 2012 (04-12) beneath mechanically fastened file roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G' TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side l ps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited -per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened the roof systems (Base Sheet Limited per 5.6.3).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published riequirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours. j
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6'" EDITIONI(2017) FBC NON-HVH2 EVALUATION FL5259-R27
Polyglass RI of Underlayments; (570) 394-1230 Revision 23: 09/14/2017
Page 13 of 14
CYD
TRINITY I ERb
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
a. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.. The following
plants have qualified products under their respective physical properties specifications.
�)a x..
e►irica iorip ..
NINE Mrr. ,
Fernley, NV, Hazleton, PA & Winter Haven, FL
ASTM D1970
Polystick MU-X
Hazleton, PA
M-D 13-0004
Elastoflex G TU
Hazleton, PA & Winter Haven, FL
ASTM D1970
Polystick IR-Xe
ASTM D1970 & TAS 203
Polystick TU Plus
ASTM D1970 & TAS 103
Pol stick TU Max
Tuscaloosa, AL
ASTM D4601, Type II
Polyglass G2 Base
Winter Haven, FL
ASTM D226 (physicals)
Elastobase, Elastobase P
ASTM D6509
Polyglass APP Base
TAS 103
Polystick MTS
ASTM D1970 & TAS 103
Polystick TU P
FRSA/TRI April 2012
Polyflex SAP, Polyflex SA P. FR
ASTM D1970
Polystick Dual Pro
ASTM D1970 & TAS 103
Polystick Tile Pro
ASTM D6164
Elastoflex S6, Elastoflex 56 G FR
ASTM D6222
I Polyflex G, Polyflex G FR
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report P32060.02.09-R23
CrrtiykateoJAuthoriiation#9503 6t" EDITION (2017) FBC NON-HVH2 EVALUATION. FL5259-1127
Polyglass Roof Underlayments, (570) 384-1230. Revision 23: 09/14/2017
Page 14 of 14