Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPIFia.AvT(VO, ervi es Department �r ode Regulati ns Division WANNEU 2300 VirgBart Ui�p, FL4982 — (772) 462-1553 13Y. 1 St Lucie Counti, Certifica Project Name: HAB - Deer Park Project Address: 7901 Deer Park Ave. Ft. Pierce, FL Permit #: Occupancy Type: VB iance Construction Type: R-3 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition I o Any accessory structure requiring a building permit FILE COPY o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS!USED: (complete all that apply) 1. DESIGN CODE: Florida Residential Code Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): XI Enclosed Partially Enclosed Open 3. Risk Category: ._I X II III IV Exposure Category: x B C D 4. Design Wind Velocity 160 mph ASD x LRFD End Zone Width: ft 5. Mean Roof Height 10' 11" ft Roof Pitch: 4 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: -38.52 Zone 2: -73.37 Zone 3: -108.49 Zone 4: -49.95 Zone 5: -61.66 Garage: -50.01 7. Design Loads: Floor: PSF - Roof/Dead: 20 PSF Roof/Live: 20 Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? x Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best ofjgVlJ�yledge and belief, the attached plans & specifications have been designed to comply with the appl� �aitftictrio sons of the building codes currently adopted and enforced by St. Lucie ��'' !,� d County. I also cert,s��rq•I o• ��depicted on these plans provide adequate resistance to the design forces specified: Q� �► g008 r,,,n%ony Tombo FL. 80083 31615 ®* ° ame Cert # & Co. Cert Auth. 'i ,� •� le House Engineering, LLC. Anthony T. Tombo,' Signature, Date, an w •••'„+451 St. Lucie Blvd. Fort Pierce, FL 34946 inusaill Company Name & Address Revised 07/25/2014 SERIAL c 3B BCA221000000004C 1287 DF