HomeMy WebLinkAboutENERGY EFFICIENCY CODEBANNED
FORM R405-2017 I*v
ff fIFUDA ENERGY EFFICIMUMb9dE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 7901 Deer ParkFort Pier a FL
B Ider Name: Habitat for Humanity
Street: 7901 Deer Park Avenue sy q g
MAY G� AU
Pe it Office:
City, State, Zip: Fort Pierce , FL , 34950
Pe mit Number:
Owner: Joseph W. Gianna �����itil�r diction:
Design Location: FL, VERO_BEACH_MUN ClLL_wVR�otln
nty:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1344.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1116.00 ft2
b. Concrete Block - Int Insul, Adjacent
R=4.1 228.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (13114.0 sgfL)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1384.00 ft2
6. Conditioned floor area above grade (ft2) 1384 1
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(160.8 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 277
a. U-Factor. Sgl, U=0.33 160.75 ft211
SHGC: SHGC=0.22
b. U-Factor: N/A ft2'
12. Cooling systems
kBtu/hr Efficiency
SHGC: i
a. Central Unit
35.0 SEER:16.00
c. U-Factor: N/A ft2J
SHGC: i
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2;
a. Electric Strip Heat
27.3 COP:1.00
SHGC: 1
Area Weighted Average Overhang Depth: 2.000 ft.1
Area Weighted Average SHGC: 0.220
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1384.1 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1384.10 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2 I
15. Credits
CF
Glass/Floor Area: 0.116 Total Proposed Modified Loads: 46.36
PASS •
Total Baseline Loads: 48.36
I hereby certify that the plans and specifications covered by
Review of the plans and
4-fHE SrgT
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: _Z�
DATE:
Beforebuilding construction
inspected scompl for
9 Pq
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
A.
with the Florida Energy Code.
COD WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: f
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FILE C®PY
3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
r
PROJECT
Title: 7901 Deer ParkFort Pierce FL
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1384
Lot #
Owner Name: Joseph W. Gianna
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: Habitat for Humanity
Rotate Angle: 0
Street:
7901 Deer Park
Avenue
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type: Single-family
FL, 34950
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating'
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, VERO_BEACH_MUNI FL_VERO_BEACH_MUNI 45
90
70
75
299
64
Medium
BLOCKS
Number Name
Area
Volume
1 Entire House
1384 11072
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 Bedroom 1
203
16241 No
2
1
1
Yes
Yes
Yes
2 Clst 1
19
152 No
0
1
Yes
Yes
Yes
3 Bath 1
93
744 No
0
1
Yes
Yes
Yes
4 Dn Clst
16
128 No
0
1
Yes
Yes
Yes
5 Kitchen
128
1024 Yes
0
1
Yes
Yes
Yes
6 Bedroom 3
168
1344 No
1
1
1
Yes
Yes
Yes
7 Bath 2
113
900 No
0
1
Yes
Yes
Yes
8 Clst 3
20
160 1 No
0
1
Yes
Yes
Yes
9 Clst 2
16
128 No
0
1
Yes
Yes
Yes
10 Bedroom 2
171
1368, No
1
1
1
Yes
Yes
Yes
11 Dining
105
842 1 No
0
1
Yes
Yes
Yes
12 Living Room
332
2656 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Bedroom 1 14.5 ft 0
203 ft2
_
1 0
0
2 Slab -On -Grade Edge Insulatio
Clst 1 2.5 ft 0
18.8 ft2
1 0
0
3 Slab -On -Grade Edge Insulatio
Bath 1 19.5 ft 0
93.3 ft2
1 0
0
4 Slab -On -Grade Edge Insulatio
Dn Clst 2.5 ft 0
16.3 ft2
1 0
0
5 Slab -On -Grade Edge Insulatio
Kitchen 9.5 ft 0
128.3 ft'
1 0
0
3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
Bedroom 3 24.5 ft 0
168 ft2
e
1
0
0
7 Slab -On -Grade Edge Insulatio
Bath 2 9 ft
0
112.5 ft2
-
1
0
0
8 Slab -On -Grade Edge Insulatio
Clst 3 3 ft
0
19.5 ft2
1
0
0
9 Slab -On -Grade Edge Insulatio
Clst 2 , 2.5 ft
0
16.3 ft2
r
1
0
0
10SIab-On-Grade Edge Insulatio
Bedroom 2 30.5 ft 0
171.3 ft2
e
1
0
0
11SIab-On-Grade Edge Insulatio
Dining 6.5 ft 0
105.3 ft2
-
1
0
0
12SIab-On-Grade Edge Insulatio
Living Room 15 ft
0
331.5 ft2
-
1
0
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Composition shingles 1459 ft2
230 ft2 Medium
. 0.9
No
0.9
No
0
18.4
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
300
1384 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
Bedroom 1
30
Blown
203 ft2
0.1
Wood
2 Under Attic (Vented)
Clst 1
30
Blown
19 ft2
0.1
Wood
3 Under Attic (Vented)
Bath 1
30
Blown
93 ft2
0.1
Wood
4 Under Attic (Vented)
Dn Clst
30
Blown
16 ft2
0.1
Wood
5 Under Attic (Vented)
Kitchen
30
Blown
128 ft2
0.1
Wood
6 Under Attic (Vented)
Bedroom 3
30
Blown
168 ft2
0.1
Wood
7 Under Attic (Vented)
Bath 2
30
Blown
113 ft2
0.1
Wood
8 Under Attic (Vented)
Clst 3
30
Blown
20 ft2
0.1
Wood
9 Under Attic (Vented)
Clst 2
30
Blown
16 ft2
0.1
Wood
10 Under Attic (Vented)
Bedroom 2
30
Blown
171 ft2
0.1
Wood
11 Under Attic (Vented)
Dining
30
Blown
105 ft2
0.1
Wood
12 Under Attic (Vented)
Living Room
30
Blown
332 ft2
0.1
Wood
WALLS
Adjacent
pace Cavity Width
SRvaillp Ft In
Height
Ft In
Area
Sheathing Framing
P-Value
Solar
Below
_ 1 W Exterior Concrete Block - Int InsuBedroom 1
4.1 14
6 8
0
116.0 ft2
0
0
0.8
0
2 N Garage Concrete Block
- Int InsuBedroom 1
4.1 14
0 8
0
112.0 ft2
0
0
0.8
0
3 W Exterior Concrete Block
- Int Insul Clst 1
4.1 2
6 8
0
20.0 ft2
0
0
0.8
0
_ 4 S Exterior Concrete Block
- Int Insul Bath 1
4.1 14
0 8
0
112.0 ft2
0
0
0.8
0
3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
10
Space
Wall Type
5
W
Exterior
Concrete Block - Int Insul Bath 1
4.1
5
6
8 0
44.0 ft2
0
0 0.8
0
_ 6
S
Exterior
Concrete Block - Int Insul Dn Clst
4.1
2
6
8 0
20.0 ft2
0
0 0.8
0
7
S
Exterior
Concrete Block - Int Insul Kitchen
4.1
9
6
8 0
76.0 ft2
0
0 0.8
0
8
E
Exterior
Concrete Block - Int InsuBedroom 3
4.1
12
0
8 0
96.0 ft2
0
0 0.8
0
_
9
S
Exterior
Concrete Block - Int InsuBedroom 3
4.1
12
6
8 0
100.0 ft2
0
0 0.8
0
10
E
Exterior
Concrete Block - Int Insul Bath 2
4.1
9
0
8 0
72.0 ft2
0
0 0.8
0
11
E
Exterior
Concrete Block - Int Insul Clst 3
4.1
3
0
8 0
24.0 ft2
0
0 0.8
0
12
E
Exterior
Concrete Block - Int Insul Clst 2
4.1
2
6
8 0
20.0 ft2
0
0 0.8
0
13
N
Exterior
Concrete Block - Int InsuBedroom 2
4.1
12
6
8 0
100.0 ft2
0
0 0.8
0
14
E
Exterior
Concrete Block - Int InsuBedroom 2
4.1
12
6
8 0
100.0 ft-7
0
0 0.8
0
-15
W
Exterior
Concrete Block - Int InsuBedrol m 2
4.1
5
6
8 0
44.0 ft2
0
0 0.8
0
-16
S
Exterior
Concrete Block - Int Insul DiniIng
4.1
6
6
8 0
52.0 ft2
0
0 0.8
0
-17
N
Exterior
Concrete Block - Int Insdtiving Room
4.1
15
0
8 0
120.0 ft2
0
0 0.8
0
-18
W
Garage
Concrete Block - Int Insdiiving Room
4.1
11
0
8 0
88.0 ft2
0
0 0.8
0
-19
N
Garage
Concrete Block - Int InsdLiving Room
4.1
3
6
8 0
28.0 ft2
0
0 0.8
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
eighln
Area
Ft
In
Ft
1
N
Wood Living Room
None
.39
3
7
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
W 1
None Single (Clear) Yes,
0.33
0.22
Y
18.3 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
2
S 4
None Single (Clear) Yes
0.33
0.22
Y
7.8 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
3
S 7
None Single (Clear) Yes
0.33
0.22
Y
9.0 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
4
E 8
None Single (Clear) Yes,
0.33
0.22
Y
17.9 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
5
S 9
None Single (Clear) Yes
0.33
0.22
Y
18.3 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
6
E 10
None Single (Clear) Yes
0.33
0.22
Y
7.8 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
7
N 13
None Single (Clear) Yes
0.33
0.22
Y
18.3 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
8
E 14
None Single (Clear) Yes,
0.33
0.22
Y
18.3 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
9
S 16
Vinyl Single (Clear) Yes
0.33
0.22
Y
21.0 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
10
N 17
None Single (Clear) Yes
0.33
0.22
Y
24.0 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
382.8 f12 382.8 ft2
64 ft
8 ft
1
3/29/2018 2:16 PM EnergyGauge® USA-,FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6
rWWRA Rdnr,_7nl7
INFILTRATION
#, Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000264
922.5 50.64 95.24 .1906 5
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity Block
Ducts
1 Electric Strip Heat/
None
COPA 27.3 kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
SEER: 16 35 kBtu/hr 1050 cfm 0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt Conservation
1 Electric None
Garage
0.95 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
— Supply ---
V # Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1 Attic 6 277 ft2
Attic
69 ft2 Default Leakage Attic (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
CoolingJan ]Feb Mar
HeatinJan �X] Feb kiMar
Ventin Jan [ ] Feb Mar
Ceiling Fans:
Apr Ma rlJun Jul Au Se Oct Nov
Apr MayJun Jul Aug Sep f _� Oct Nov
[X Apr [ May Jun Jul AugSe LX Oct Nov
Dec
Dec
Dec
3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2017
Thermostat Schedule:
Schedule Type
HERS 2006 Reference
1
2
3
4
5
Hours
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65.
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
651
65
65
65
65
68
68
68
68
68
PM
68
68
68;
68
68
68
68
68
68
68
68
68
3/29/2018 2:16 PM EnergyGauge® USA FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6
I
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
i
7901 Deer Park Avenue, Fort Pierce, FL, 34950
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior
R=4.1
1116.00 ft2
b. Concrete Block - Int Insul, Adjacent
R=4.1
228.00 ft2
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
3 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No a. Under Attic (Vented)
R=30.0
1384.00 ft2
6. Conditioned floor area (ft2)
1384 b. N/A
R=
ft2
7. Windows- Description
Area c. N/A
R=
ft2
11. Ducts
R ft2
a. U-Factor: Sgl, U=0.33
160.75 ft2 a. Sup: Attic, Ret: Attic, AH: Attic
6 277
SHGC: SHGC=0.22
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit
35.0 SEER:16.00
SHGC:
d. U-Factor: N/A
ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
27.3
COP:1.00
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.220
8. Floor Types
Insulation Area 14. Hot water systems
Cap:
40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1384.10 ft2 a. Electric
EF: 0.95
b. N/A
R= ft2
c. N/A
R= ft2 b. Conservation features
None
15. Credits
CF
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/29/2018 2:17 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and'Professional Regulation - Residential Performance Method
Project Name: 7901 Deer ParkFort Pierce FL
Builder Name: Habitat for Humanity
Street: 7901 Deer Park Avenue
Permit Office:
City, State, Zip: Fort Pierce, FL , 34950
Permit Number.
Owner: Joseph W. Gianna
Jurisdiction:
Design Location: FL, VERO_BEACH_MUNICIPAL ARPT
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1344.0 sqft.)
Insulation Area
2, Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1116.00 ft2
b. Concrete Block - Int Insul, Adjacent
R=4.1 228.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1384.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1384.00 ft2
6. Conditioned floor area above grade (ft2) 1384
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(160.8 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 277
a. U-Factor: Sgl, U=0.33 160.75 f12
SHGC: SHGC=0.22
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
35.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
27.3 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.220
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1384.1 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1384.10 1112
b. Conservation features
b. N/A R= ft2
None
c. NIA R= ft2
15. Credits
CF
Glass/Floor Area: 0.116 Total Proposed Modified Loads: 46.36
PASS
Total Baseline Loads: 48.36
1 hereby certify that the plans and specifications covered by
Review of the plans and
61 ST�g1,
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
O
with the Florida Energy Code.
,n„>'�.:::i•';,- �,
PREPARED BY:441141--�Before
DATE: 3- n 11
construction is completed
this building will be inspected ford,
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
COD
with the Florida Energy Code.
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
PROJECT
Title: 7901 Deer ParkFort Pierce FL
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1384
Lot #
Owner Name: Joseph W. Gianna
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: Habitat for Humanity
Rotate Angle: 0
Street:
7901 Deer Park
Avenue
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type: Single-family
FL, 34950
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, VERO_BEACH_MUNI FL VERO_BEACH _MUNI 45
90
70
75
299
64
Medium
BLOCKS
Number Name
Area
Volume
1 Entire House
1384 11072
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 Bedroom 1
203
1624 No
2
1
1
Yes
Yes
Yes
2 Clst 1
19
152 No
0
1
Yes
Yes
Yes
3 Bath 1
93
744 No
0
1
Yes
Yes
Yes
4 Dn Clst
16
128 No
0
1
Yes
Yes
Yes
5 Kitchen
128
1024 Yes
0
1
Yes
Yes
Yes
6 Bedroom 3
168
1344 No
1
1
1
Yes
Yes
Yes
7 Bath 2
113
900 No
0
1
Yes
Yes
Yes
8 Clst 3
20
160 No
0
1
Yes
Yes
Yes
9 Clst 2
16
128 No
0
1
Yes
Yes
Yes
10 Bedroom 2
171
1368 No
1
1
1
Yes
Yes
Yes
11 Dining
105
842 No
0
1
Yes
Yes
Yes
12 Living Room
332
2656 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Bedroom 1 14.5 ft 0
203 ft2
—
1 0
0
2 Slab -On -Grade Edge Insulatio
Clst 1 2.5 ft 0
18.8 ft2
—
1 0
0
3 Slab -On -Grade Edge Insulatio
Bath 1 19.5 ft 0
93.3 ft2
e
1 0
0
4 Slab -On -Grade Edge Insulatio
Dn Clst 2.5 ft 0
16.3 ft2
—
1 0
0
5 Slab -On -Grade Edge Insulatio
Kitchen 9.5 ft 0
128.3 ft2
—
1 0
0
3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017
FLOORS
# Floor Type
Space Perimeter Perimeter R Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
Bedroom 3 24.5 ft 0
168 ft2
-
1
0
0
7 Slab -On -Grade Edge Insulatio
Bath 2 9 ft
0
112.5 ft2
e
1
0
0
8 Slab -On -Grade Edge Insulatio
Clst 3. 3 ft
0
19.5 ft2
a
1
0
0
9 Slab -On -Grade Edge Insulatio
I
Clst 2 2.5 ft 0
16.3 ft2
-
1
0
0
10SIab-On-Grade Edge Insulatio
Bedroom 2 30.5 ft 0
171.3 ft2
e
1
0
0
11SIab-On-Grade Edge Insulatio
Dining 6.5 ft 0
105.3 ft2
-
1
0
0
12SIab-On-Grade Edge Insulatio
Living Room 15 ft
0
331.5 ft2
M
1
0
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Composition shingles 1459 ft2
230 ft2 Medium
0.9
No
0.9
No
0
18.4
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
300
1384 ft2
N
N
CEILING
# Ceiling Type
Space
R Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
Bedroom 1
30
Blown
203 ft2
0.1
Wood
2 Under Attic (Vented)
Clst 1
30
Blown
19 ft2
0.1
Wood
3 Under Attic (Vented)
Bath 1
30
Blown
93 ft2
0.1
Wood
4 Under Attic (Vented)
Dn Clst
30
Blown
16 ft2
0.1
Wood
5 Under Attic (Vented)
Kitchen
30
Blown
128 ft2
0.1
Wood
6 Under Attic (Vented)
Bedroom 3
30
Blown
168 ft2
0.1
Wood
7 Under Attic (Vented)
Bath 2
30
Blown
113 ft2
0.1
Wood
8 Under Attic (Vented)
Clst 3
30
Blown
20 ft2
0.1
Wood
9 Under Attic (Vented)
Clst 2
30
Blown
16 ft2
0.1
Wood
10 Under Attic (Vented)
Bedroom 2
30
Blown
171 ft2
0.1
Wood
11 Under Attic (Vented)
Dining
30
Blown
105 ft2
0.1
Wood
12 Under Attic (Vented)
Living Room
30
Blown
332 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
Space
1 W Exterior Concrete Block - Int InsulBedroom 1
4.1 14
6 8
0
116.0 ft2
0
0
0.8
0
2 N Garage Concrete Block - Int InsuBedroom 1
4.1 14
0 8
0
112.0 ft2
0
0
0.8
0
3 W - Exterior Concrete Block
- Int Insul Clst 1
4.1 2
6 8
0
20.0 ft2
0
0
0.8
0
4 S Exterior Concrete Block - Int Insul Bath 1
4.1 14
0 8
0
112.0 ft2
0
0
0.8
0
3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6
FORM R401F-9017
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
Space
R-Val-le
Et
In
Et In
Area
R-Xallle
Fraction Absor
Grade%-
5
W
Exterior
Concrete Block - Int Insul Bath 1
4.1
5
6
8 0
44.0 ft2
0
0 0.8
0
6
S
Exterior
Concrete Block - Int Insul Dn Clst
4.1
2
6
8 0
20.0 ft2
0
0 0.8
0
7
S
Exterior
Concrete Block - Int Insul Kitchen
4.1
9
6
8 0
76.0 ft2
0
0 0.8
0
8
E
Exterior
Concrete Block - Int InsuBedroom 3
4.1
12
0
8 0
96.0 112
0
0 0.8
0
_
9
S
Exterior
Concrete Block - Int InsuBedroom 3
4.1
12
6
8 0
100.0 ft2
0
0 0.8
0
10
E
Exterior
Concrete Block - Int Insul Bath 2
4.1
9
0
8 0
72.0 ft2
0
0 0.8
0
11
E
Exterior
Concrete Block - Int Insul Clst 3
4.1
3
0
8 0
24.0 ft2
0
0 0.8
0
12
E
Exterior
Concrete Block - Int Insul Clst 2
4.1
2
6
8 0
20.0 ft2
0
0 0.8
0
13
N
Exterior
Concrete Block - Int InsuBedroom 2
4.1
12
6
8 0
100.0 ft2
0
0 0.8
0
14
E
Exterior
Concrete Block - Int InsuBedroom 2
4.1
12
6
8 0
100.0 ft2
0
0 0.8
0
15
W
Exterior
Concrete Block - Int InsuBedroom 2
4.1
5
6
8 0
44.0 ft2
0
0 0.8
0
_ 16
S
Exterior
Concrete Block - Int Insul Dining
4.1
6
6
8 0
52.0 ft2
0
0 0.8
0
_ 17
N
Exterior
Concrete Block - Int Insd Living Room
4.1
15
0
8 0
120.0 ft2
0
0 0.8
0
_ 18
W
Garage
Concrete Block - Int InsdLiving Room
4.1
11
0
8 0
88.0 ft2
0
0 0.8
0
_ 19
N
Garage
Concrete Block - Int InsdLiving Room
4.1
3
6
8 0
28.0 ft2
0
0 0.8
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
to
Ft In
1
N
Wood Living Room
None
.39
3
7
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
W 1
None Single (Clear) Yes
0.33
0.22
Y
18.3 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
2
S 4
None Single (Clear) Yes
0.33
0.22
Y
7.8 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
3
S 7
None Single (Clear) Yes
0.33
0.22
Y
9.0 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
4
E 8
None Single (Clear) Yes
0.33
0.22
Y
17.9 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
5
S 9
None Single (Clear) Yes
0.33
0.22
Y
18.3 it'
2 it 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
6
E 10
None Single (Clear) Yes
0.33
0.22
Y
7.8 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
7
N 13
None Single (Clear) Yes
0.33
0.22
Y
18.3 ft2
It 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
8
E 14
None Single (Clear) Yes
0.33
0.22
Y
18.3 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
9
S 16
Vinyl Single (Clear) Yes
0.33
0.22
Y
21.0 ft2
2 ft 0 in
1 It 0 in
Drapes/blinds
Exterior 5
10
N 17
None Single (Clear) Yes
0.33
0.22
Y
24.0 ft2
2 it 0 in
1 It 0 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
382.8 ft2 382.8 ft2
64 ft
8 ft
1
3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6
POPRR PAflr,_9f117
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000254
922.5 50.64 95.24 .1906 5
HEATING SYSTEM
# System Type
Subtype!
Efficiency Capacity Block
Ducts
1 Electric Strip Heat/
None
COPA 27.3 kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
SEER: 16 35 kBtu/hr 1050 cfm 0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubTpe
Location
EF Cap Use SetPnt Conservation
1 Electric None
Garage
0.95 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
— Supply —
V # Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1 Attic 6 277 ft2
Attic
69 ft2 Default Leakage Attic (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
CoolingJan ]Feb Mar
HeatinHJan �X] Feb kiMar
Ventin Jan [ ]Feb Mar
Ceiling Fans:
A r Ma X Jun Jul [X] Au Se [ j Oct Nov
Apr May 4 Jun Jul [ ] ASep [ ]Oct Nov
[X A r [ Ma [ Jun Jul [ ] Augu Se [X] Oct Nov
Dec
Dec
Dec
3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017
Thermostat Schedule:
Schedule Type
HERS 2006
Reference
1
2
3
4
5
Hours
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (VVD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
.4
3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2017
ENERGY PER FORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDI
The lower the EnergyPerformance Index, the more efficient #
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows- Description
a. U-Factor: Sgl, U=0.33
SHGC: SHGC=0.22
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: NIA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
7901 Deer -Park Avenue, Fort Pierce, FL, 34950
New (From Plans)
Single-family
1
3
No
1384
Area
160.75 ftz
Insulation
R=0.0
R=
R=
9. Wall Types
a. Concrete Block - Int Insul, Exterior
b. Concrete Block - Int Insul, Adjacent
c. N/A
d. N/A
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
c. N/A
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
ftz
12. Cooling systems
ftz a. Central Unit
ftz
2.000 ft.
0.220
Area
1384.10 ftz
ftz
ftz
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florid'a Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a -new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
Insulation
R=4.1
R=4.1
R=
R=
Insulation
R=30.0
R=
R=
Area
1116.00 ftz
228.00 ftz
ftz
ftz
Area
1384.00 ftz
ftz
ftz
R ftz
6 277
kBtu/hr Efficiency
35.0 SEER:16.00
kBtu/hr Efficiency
27.3 COP:1.00
Cap: 40 gallons
EF: 0.95
CF
*Note: This is not a Building Energy Rating.- If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/29/2018 2:17 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1