Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEBANNED FORM R405-2017 I*v ff fIFUDA ENERGY EFFICIMUMb9dE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 7901 Deer ParkFort Pier a FL B Ider Name: Habitat for Humanity Street: 7901 Deer Park Avenue sy q g MAY G� AU Pe it Office: City, State, Zip: Fort Pierce , FL , 34950 Pe mit Number: Owner: Joseph W. Gianna �����itil�r diction: Design Location: FL, VERO_BEACH_MUN ClLL_wVR�otln nty:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1344.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1116.00 ft2 b. Concrete Block - Int Insul, Adjacent R=4.1 228.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (13114.0 sgfL) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1384.00 ft2 6. Conditioned floor area above grade (ft2) 1384 1 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(160.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 277 a. U-Factor. Sgl, U=0.33 160.75 ft211 SHGC: SHGC=0.22 b. U-Factor: N/A ft2' 12. Cooling systems kBtu/hr Efficiency SHGC: i a. Central Unit 35.0 SEER:16.00 c. U-Factor: N/A ft2J SHGC: i 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2; a. Electric Strip Heat 27.3 COP:1.00 SHGC: 1 Area Weighted Average Overhang Depth: 2.000 ft.1 Area Weighted Average SHGC: 0.220 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1384.1 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1384.10 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 I 15. Credits CF Glass/Floor Area: 0.116 Total Proposed Modified Loads: 46.36 PASS • Total Baseline Loads: 48.36 I hereby certify that the plans and specifications covered by Review of the plans and 4-fHE SrgT this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: _Z� DATE: Beforebuilding construction inspected scompl for 9 Pq compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. A. with the Florida Energy Code. COD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: f DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FILE C®PY 3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 r PROJECT Title: 7901 Deer ParkFort Pierce FL Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1384 Lot # Owner Name: Joseph W. Gianna Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Habitat for Humanity Rotate Angle: 0 Street: 7901 Deer Park Avenue Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34950 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating' Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, VERO_BEACH_MUNI FL_VERO_BEACH_MUNI 45 90 70 75 299 64 Medium BLOCKS Number Name Area Volume 1 Entire House 1384 11072 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Bedroom 1 203 16241 No 2 1 1 Yes Yes Yes 2 Clst 1 19 152 No 0 1 Yes Yes Yes 3 Bath 1 93 744 No 0 1 Yes Yes Yes 4 Dn Clst 16 128 No 0 1 Yes Yes Yes 5 Kitchen 128 1024 Yes 0 1 Yes Yes Yes 6 Bedroom 3 168 1344 No 1 1 1 Yes Yes Yes 7 Bath 2 113 900 No 0 1 Yes Yes Yes 8 Clst 3 20 160 1 No 0 1 Yes Yes Yes 9 Clst 2 16 128 No 0 1 Yes Yes Yes 10 Bedroom 2 171 1368, No 1 1 1 Yes Yes Yes 11 Dining 105 842 1 No 0 1 Yes Yes Yes 12 Living Room 332 2656 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bedroom 1 14.5 ft 0 203 ft2 _ 1 0 0 2 Slab -On -Grade Edge Insulatio Clst 1 2.5 ft 0 18.8 ft2 1 0 0 3 Slab -On -Grade Edge Insulatio Bath 1 19.5 ft 0 93.3 ft2 1 0 0 4 Slab -On -Grade Edge Insulatio Dn Clst 2.5 ft 0 16.3 ft2 1 0 0 5 Slab -On -Grade Edge Insulatio Kitchen 9.5 ft 0 128.3 ft' 1 0 0 3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio Bedroom 3 24.5 ft 0 168 ft2 e 1 0 0 7 Slab -On -Grade Edge Insulatio Bath 2 9 ft 0 112.5 ft2 - 1 0 0 8 Slab -On -Grade Edge Insulatio Clst 3 3 ft 0 19.5 ft2 1 0 0 9 Slab -On -Grade Edge Insulatio Clst 2 , 2.5 ft 0 16.3 ft2 r 1 0 0 10SIab-On-Grade Edge Insulatio Bedroom 2 30.5 ft 0 171.3 ft2 e 1 0 0 11SIab-On-Grade Edge Insulatio Dining 6.5 ft 0 105.3 ft2 - 1 0 0 12SIab-On-Grade Edge Insulatio Living Room 15 ft 0 331.5 ft2 - 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1459 ft2 230 ft2 Medium . 0.9 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1384 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Bedroom 1 30 Blown 203 ft2 0.1 Wood 2 Under Attic (Vented) Clst 1 30 Blown 19 ft2 0.1 Wood 3 Under Attic (Vented) Bath 1 30 Blown 93 ft2 0.1 Wood 4 Under Attic (Vented) Dn Clst 30 Blown 16 ft2 0.1 Wood 5 Under Attic (Vented) Kitchen 30 Blown 128 ft2 0.1 Wood 6 Under Attic (Vented) Bedroom 3 30 Blown 168 ft2 0.1 Wood 7 Under Attic (Vented) Bath 2 30 Blown 113 ft2 0.1 Wood 8 Under Attic (Vented) Clst 3 30 Blown 20 ft2 0.1 Wood 9 Under Attic (Vented) Clst 2 30 Blown 16 ft2 0.1 Wood 10 Under Attic (Vented) Bedroom 2 30 Blown 171 ft2 0.1 Wood 11 Under Attic (Vented) Dining 30 Blown 105 ft2 0.1 Wood 12 Under Attic (Vented) Living Room 30 Blown 332 ft2 0.1 Wood WALLS Adjacent pace Cavity Width SRvaillp Ft In Height Ft In Area Sheathing Framing P-Value Solar Below _ 1 W Exterior Concrete Block - Int InsuBedroom 1 4.1 14 6 8 0 116.0 ft2 0 0 0.8 0 2 N Garage Concrete Block - Int InsuBedroom 1 4.1 14 0 8 0 112.0 ft2 0 0 0.8 0 3 W Exterior Concrete Block - Int Insul Clst 1 4.1 2 6 8 0 20.0 ft2 0 0 0.8 0 _ 4 S Exterior Concrete Block - Int Insul Bath 1 4.1 14 0 8 0 112.0 ft2 0 0 0.8 0 3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below 10 Space Wall Type 5 W Exterior Concrete Block - Int Insul Bath 1 4.1 5 6 8 0 44.0 ft2 0 0 0.8 0 _ 6 S Exterior Concrete Block - Int Insul Dn Clst 4.1 2 6 8 0 20.0 ft2 0 0 0.8 0 7 S Exterior Concrete Block - Int Insul Kitchen 4.1 9 6 8 0 76.0 ft2 0 0 0.8 0 8 E Exterior Concrete Block - Int InsuBedroom 3 4.1 12 0 8 0 96.0 ft2 0 0 0.8 0 _ 9 S Exterior Concrete Block - Int InsuBedroom 3 4.1 12 6 8 0 100.0 ft2 0 0 0.8 0 10 E Exterior Concrete Block - Int Insul Bath 2 4.1 9 0 8 0 72.0 ft2 0 0 0.8 0 11 E Exterior Concrete Block - Int Insul Clst 3 4.1 3 0 8 0 24.0 ft2 0 0 0.8 0 12 E Exterior Concrete Block - Int Insul Clst 2 4.1 2 6 8 0 20.0 ft2 0 0 0.8 0 13 N Exterior Concrete Block - Int InsuBedroom 2 4.1 12 6 8 0 100.0 ft2 0 0 0.8 0 14 E Exterior Concrete Block - Int InsuBedroom 2 4.1 12 6 8 0 100.0 ft-7 0 0 0.8 0 -15 W Exterior Concrete Block - Int InsuBedrol m 2 4.1 5 6 8 0 44.0 ft2 0 0 0.8 0 -16 S Exterior Concrete Block - Int Insul DiniIng 4.1 6 6 8 0 52.0 ft2 0 0 0.8 0 -17 N Exterior Concrete Block - Int Insdtiving Room 4.1 15 0 8 0 120.0 ft2 0 0 0.8 0 -18 W Garage Concrete Block - Int Insdiiving Room 4.1 11 0 8 0 88.0 ft2 0 0 0.8 0 -19 N Garage Concrete Block - Int InsdLiving Room 4.1 3 6 8 0 28.0 ft2 0 0 0.8 0 DOORS # Omt Door Type Space Storms U-Value Width eighln Area Ft In Ft 1 N Wood Living Room None .39 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 None Single (Clear) Yes, 0.33 0.22 Y 18.3 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 2 S 4 None Single (Clear) Yes 0.33 0.22 Y 7.8 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 3 S 7 None Single (Clear) Yes 0.33 0.22 Y 9.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 4 E 8 None Single (Clear) Yes, 0.33 0.22 Y 17.9 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 5 S 9 None Single (Clear) Yes 0.33 0.22 Y 18.3 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 6 E 10 None Single (Clear) Yes 0.33 0.22 Y 7.8 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 7 N 13 None Single (Clear) Yes 0.33 0.22 Y 18.3 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 8 E 14 None Single (Clear) Yes, 0.33 0.22 Y 18.3 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 9 S 16 Vinyl Single (Clear) Yes 0.33 0.22 Y 21.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 10 N 17 None Single (Clear) Yes 0.33 0.22 Y 24.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 f12 382.8 ft2 64 ft 8 ft 1 3/29/2018 2:16 PM EnergyGauge® USA-,FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 rWWRA Rdnr,_7nl7 INFILTRATION #, Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000264 922.5 50.64 95.24 .1906 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27.3 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 35 kBtu/hr 1050 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply --- V # Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 277 ft2 Attic 69 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N CoolingJan ]Feb Mar HeatinJan �X] Feb kiMar Ventin Jan [ ] Feb Mar Ceiling Fans: Apr Ma rlJun Jul Au Se Oct Nov Apr MayJun Jul Aug Sep f _� Oct Nov [X Apr [ May Jun Jul AugSe LX Oct Nov Dec Dec Dec 3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2017 Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 Hours 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65. 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 651 65 65 65 65 68 68 68 68 68 PM 68 68 68; 68 68 68 68 68 68 68 68 68 3/29/2018 2:16 PM EnergyGauge® USA FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6 I FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. i 7901 Deer Park Avenue, Fort Pierce, FL, 34950 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1116.00 ft2 b. Concrete Block - Int Insul, Adjacent R=4.1 228.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1384.00 ft2 6. Conditioned floor area (ft2) 1384 b. N/A R= ft2 7. Windows- Description Area c. N/A R= ft2 11. Ducts R ft2 a. U-Factor: Sgl, U=0.33 160.75 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 277 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 35.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 27.3 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.220 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1384.10 ft2 a. Electric EF: 0.95 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits CF I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/29/2018 2:17 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and'Professional Regulation - Residential Performance Method Project Name: 7901 Deer ParkFort Pierce FL Builder Name: Habitat for Humanity Street: 7901 Deer Park Avenue Permit Office: City, State, Zip: Fort Pierce, FL , 34950 Permit Number. Owner: Joseph W. Gianna Jurisdiction: Design Location: FL, VERO_BEACH_MUNICIPAL ARPT County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1344.0 sqft.) Insulation Area 2, Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1116.00 ft2 b. Concrete Block - Int Insul, Adjacent R=4.1 228.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1384.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1384.00 ft2 6. Conditioned floor area above grade (ft2) 1384 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(160.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 277 a. U-Factor: Sgl, U=0.33 160.75 f12 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 35.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.3 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.220 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1384.1 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1384.10 1112 b. Conservation features b. N/A R= ft2 None c. NIA R= ft2 15. Credits CF Glass/Floor Area: 0.116 Total Proposed Modified Loads: 46.36 PASS Total Baseline Loads: 48.36 1 hereby certify that the plans and specifications covered by Review of the plans and 61 ST�g1, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance O with the Florida Energy Code. ,n„>'�.:::i•';,- �, PREPARED BY:441141--�Before DATE: 3- n 11 construction is completed this building will be inspected ford, compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Code. WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 PROJECT Title: 7901 Deer ParkFort Pierce FL Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1384 Lot # Owner Name: Joseph W. Gianna Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Habitat for Humanity Rotate Angle: 0 Street: 7901 Deer Park Avenue Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34950 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, VERO_BEACH_MUNI FL VERO_BEACH _MUNI 45 90 70 75 299 64 Medium BLOCKS Number Name Area Volume 1 Entire House 1384 11072 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Bedroom 1 203 1624 No 2 1 1 Yes Yes Yes 2 Clst 1 19 152 No 0 1 Yes Yes Yes 3 Bath 1 93 744 No 0 1 Yes Yes Yes 4 Dn Clst 16 128 No 0 1 Yes Yes Yes 5 Kitchen 128 1024 Yes 0 1 Yes Yes Yes 6 Bedroom 3 168 1344 No 1 1 1 Yes Yes Yes 7 Bath 2 113 900 No 0 1 Yes Yes Yes 8 Clst 3 20 160 No 0 1 Yes Yes Yes 9 Clst 2 16 128 No 0 1 Yes Yes Yes 10 Bedroom 2 171 1368 No 1 1 1 Yes Yes Yes 11 Dining 105 842 No 0 1 Yes Yes Yes 12 Living Room 332 2656 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bedroom 1 14.5 ft 0 203 ft2 — 1 0 0 2 Slab -On -Grade Edge Insulatio Clst 1 2.5 ft 0 18.8 ft2 — 1 0 0 3 Slab -On -Grade Edge Insulatio Bath 1 19.5 ft 0 93.3 ft2 e 1 0 0 4 Slab -On -Grade Edge Insulatio Dn Clst 2.5 ft 0 16.3 ft2 — 1 0 0 5 Slab -On -Grade Edge Insulatio Kitchen 9.5 ft 0 128.3 ft2 — 1 0 0 3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio Bedroom 3 24.5 ft 0 168 ft2 - 1 0 0 7 Slab -On -Grade Edge Insulatio Bath 2 9 ft 0 112.5 ft2 e 1 0 0 8 Slab -On -Grade Edge Insulatio Clst 3. 3 ft 0 19.5 ft2 a 1 0 0 9 Slab -On -Grade Edge Insulatio I Clst 2 2.5 ft 0 16.3 ft2 - 1 0 0 10SIab-On-Grade Edge Insulatio Bedroom 2 30.5 ft 0 171.3 ft2 e 1 0 0 11SIab-On-Grade Edge Insulatio Dining 6.5 ft 0 105.3 ft2 - 1 0 0 12SIab-On-Grade Edge Insulatio Living Room 15 ft 0 331.5 ft2 M 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1459 ft2 230 ft2 Medium 0.9 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1384 ft2 N N CEILING # Ceiling Type Space R Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Bedroom 1 30 Blown 203 ft2 0.1 Wood 2 Under Attic (Vented) Clst 1 30 Blown 19 ft2 0.1 Wood 3 Under Attic (Vented) Bath 1 30 Blown 93 ft2 0.1 Wood 4 Under Attic (Vented) Dn Clst 30 Blown 16 ft2 0.1 Wood 5 Under Attic (Vented) Kitchen 30 Blown 128 ft2 0.1 Wood 6 Under Attic (Vented) Bedroom 3 30 Blown 168 ft2 0.1 Wood 7 Under Attic (Vented) Bath 2 30 Blown 113 ft2 0.1 Wood 8 Under Attic (Vented) Clst 3 30 Blown 20 ft2 0.1 Wood 9 Under Attic (Vented) Clst 2 30 Blown 16 ft2 0.1 Wood 10 Under Attic (Vented) Bedroom 2 30 Blown 171 ft2 0.1 Wood 11 Under Attic (Vented) Dining 30 Blown 105 ft2 0.1 Wood 12 Under Attic (Vented) Living Room 30 Blown 332 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 W Exterior Concrete Block - Int InsulBedroom 1 4.1 14 6 8 0 116.0 ft2 0 0 0.8 0 2 N Garage Concrete Block - Int InsuBedroom 1 4.1 14 0 8 0 112.0 ft2 0 0 0.8 0 3 W - Exterior Concrete Block - Int Insul Clst 1 4.1 2 6 8 0 20.0 ft2 0 0 0.8 0 4 S Exterior Concrete Block - Int Insul Bath 1 4.1 14 0 8 0 112.0 ft2 0 0 0.8 0 3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6 FORM R401F-9017 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space R-Val-le Et In Et In Area R-Xallle Fraction Absor Grade%- 5 W Exterior Concrete Block - Int Insul Bath 1 4.1 5 6 8 0 44.0 ft2 0 0 0.8 0 6 S Exterior Concrete Block - Int Insul Dn Clst 4.1 2 6 8 0 20.0 ft2 0 0 0.8 0 7 S Exterior Concrete Block - Int Insul Kitchen 4.1 9 6 8 0 76.0 ft2 0 0 0.8 0 8 E Exterior Concrete Block - Int InsuBedroom 3 4.1 12 0 8 0 96.0 112 0 0 0.8 0 _ 9 S Exterior Concrete Block - Int InsuBedroom 3 4.1 12 6 8 0 100.0 ft2 0 0 0.8 0 10 E Exterior Concrete Block - Int Insul Bath 2 4.1 9 0 8 0 72.0 ft2 0 0 0.8 0 11 E Exterior Concrete Block - Int Insul Clst 3 4.1 3 0 8 0 24.0 ft2 0 0 0.8 0 12 E Exterior Concrete Block - Int Insul Clst 2 4.1 2 6 8 0 20.0 ft2 0 0 0.8 0 13 N Exterior Concrete Block - Int InsuBedroom 2 4.1 12 6 8 0 100.0 ft2 0 0 0.8 0 14 E Exterior Concrete Block - Int InsuBedroom 2 4.1 12 6 8 0 100.0 ft2 0 0 0.8 0 15 W Exterior Concrete Block - Int InsuBedroom 2 4.1 5 6 8 0 44.0 ft2 0 0 0.8 0 _ 16 S Exterior Concrete Block - Int Insul Dining 4.1 6 6 8 0 52.0 ft2 0 0 0.8 0 _ 17 N Exterior Concrete Block - Int Insd Living Room 4.1 15 0 8 0 120.0 ft2 0 0 0.8 0 _ 18 W Garage Concrete Block - Int InsdLiving Room 4.1 11 0 8 0 88.0 ft2 0 0 0.8 0 _ 19 N Garage Concrete Block - Int InsdLiving Room 4.1 3 6 8 0 28.0 ft2 0 0 0.8 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft to Ft In 1 N Wood Living Room None .39 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 None Single (Clear) Yes 0.33 0.22 Y 18.3 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 2 S 4 None Single (Clear) Yes 0.33 0.22 Y 7.8 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 3 S 7 None Single (Clear) Yes 0.33 0.22 Y 9.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 4 E 8 None Single (Clear) Yes 0.33 0.22 Y 17.9 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 5 S 9 None Single (Clear) Yes 0.33 0.22 Y 18.3 it' 2 it 0 in 1 ft 0 in Drapes/blinds Exterior 5 6 E 10 None Single (Clear) Yes 0.33 0.22 Y 7.8 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 7 N 13 None Single (Clear) Yes 0.33 0.22 Y 18.3 ft2 It 0 in 1 ft 0 in Drapes/blinds Exterior 5 8 E 14 None Single (Clear) Yes 0.33 0.22 Y 18.3 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 9 S 16 Vinyl Single (Clear) Yes 0.33 0.22 Y 21.0 ft2 2 ft 0 in 1 It 0 in Drapes/blinds Exterior 5 10 N 17 None Single (Clear) Yes 0.33 0.22 Y 24.0 ft2 2 it 0 in 1 It 0 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 ft 1 3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 POPRR PAflr,_9f117 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 922.5 50.64 95.24 .1906 5 HEATING SYSTEM # System Type Subtype! Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27.3 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 35 kBtu/hr 1050 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — V # Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 277 ft2 Attic 69 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N CoolingJan ]Feb Mar HeatinHJan �X] Feb kiMar Ventin Jan [ ]Feb Mar Ceiling Fans: A r Ma X Jun Jul [X] Au Se [ j Oct Nov Apr May 4 Jun Jul [ ] ASep [ ]Oct Nov [X A r [ Ma [ Jun Jul [ ] Augu Se [X] Oct Nov Dec Dec Dec 3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 Hours 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (VVD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 .4 3/29/2018 2:16 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2017 ENERGY PER FORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDI The lower the EnergyPerformance Index, the more efficient # 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows- Description a. U-Factor: Sgl, U=0.33 SHGC: SHGC=0.22 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: NIA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 7901 Deer -Park Avenue, Fort Pierce, FL, 34950 New (From Plans) Single-family 1 3 No 1384 Area 160.75 ftz Insulation R=0.0 R= R= 9. Wall Types a. Concrete Block - Int Insul, Exterior b. Concrete Block - Int Insul, Adjacent c. N/A d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic ftz 12. Cooling systems ftz a. Central Unit ftz 2.000 ft. 0.220 Area 1384.10 ftz ftz ftz 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florid'a Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a -new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Insulation R=4.1 R=4.1 R= R= Insulation R=30.0 R= R= Area 1116.00 ftz 228.00 ftz ftz ftz Area 1384.00 ftz ftz ftz R ftz 6 277 kBtu/hr Efficiency 35.0 SEER:16.00 kBtu/hr Efficiency 27.3 COP:1.00 Cap: 40 gallons EF: 0.95 CF *Note: This is not a Building Energy Rating.- If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/29/2018 2:17 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1