HomeMy WebLinkAboutQUALITY STEEL STRUCTURESRISK CATEGORY TABLE 1 BOW/RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENER SPACING SPECIFICATIONS WIND EXPOSURE ULTIMATE WIND SPEED NOMINAL WIND SPEED MAXIMUM RAFTER/BOW CATEGORY (MPH) (MPH) AND END POST SPACING (FEET) W 139 HUI AVERAGE FASTENER SPACING ON -CENTERS ALONG RAFTERS OR PURLINS, AND POSTS OR GIRTS (INCHES) INTERIOR END BOWS/RAFTERS BOWS/RAFTERS on NOTES: 1. SPECIFICATIONS APPLICABLE TO 26 GAUGE METAL PANELS FASTENED DIRECTLY TO 12 OR 14 GAUGE STEEL TUBE BOW FRAMES. 2. FASTENTERS CONSIST OF 1/4"-14XV SELF -DRILLING SCREWS WITH CONTROL SEAL WASHER. 3. SPECIFICATIONS APPLICABLE ONLY FOR MEAN ROOF HEIGHT OF 20 FEET OR LESS, AND ROOF SLOPES OF 14°(3:12 PITCH). SPACING REQUIREMENTS FOR OTHER ROOF HEIGHTS AND/OR SLOPES MAY VARY. 4. GROUND ANCHOR REQUIREMENTS ARE 1 @ EACH CORNER AND ONE EVERY OTHER INTERIOR BOW/RAFTER POST LOCATION, AT MAXIMUM OF 10, O.C., AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. 5. GROUND ANCHORS ARE NOT REQUIRED WITH CONCRETE SLAB CONSTRUCTION. 13'. 13' 1 9' X 8' ROLL -UP DOOR 9' - 24' if FRONT ELEVATION 3068 DOOR SCALE: NOT TO SCALE 10' 30' - - - LEFT AND RIGHT ELEVATION SCALE: NOT TO SCALE 6" 11' 6"- E 9' X 8' ROLL -UP DOOR WINDOW AND DOOR NOTE EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED BY AN APPROVED INDEPENDENT TESTING LABORATORY, AND BEAR AN AAMA OR WDMA OR OTHER APPROVED LABEL INDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT EVALUATION ENTITY TO INDICATE COMPLIANCE WITH THE REQUIREMENTS OF THE FOLLOWING SPECIFICATION. ANSI/AAMA/NWWDA 101/1S 2/97 THE CONSTRUCTION SHALL BE TESTED IN ACCORDANCE WITH ASTM E 330, STANDARD TEST METHODS FOR STRUCTURAL PERFORMANCE OF EXTERIOR WINDOWS, CURTAIN WALLS, AND DOORS BY UNIFORM STATIC AIR PRESSURE. DESIGN WAS DONE IN ACCORDANCE WITH THE 2017 FLORIDA BUILDING CODE 6TH ED. (FBC) WITH 2O12 SUPPLEMENT AMENDMENTS 2006 INTERNATIONAL BUILDING CODE (IBC), 2009 IBC AND 2012 IBC. GENERAL NOTES: 1. ALL STEEL SHALL BE 50 KSI STEEL. 2. FASTEN METAL ROOF AND WALL PANELS TO FRAMING WITH 1/4" 1 X 3/4" SELF DRILLING FASTENERS WITH CONTROL SEAL WASHER @ 6" „ O.C. AVERAGE. I - 11'mm51 13 - - 24' REAR ELEVATION SCALE: NOT TO SCALE 3'-0" (TYP) O O O O �J No. Date Description By Chk 11/14/18 Updated Building RJD KMB r ALL FIELD CONNECTIONS SHALL BE 1/4" X 3/4" SELF DRILLING SCREWS. ALL SHOP CONNECTIONS SHALL BE WELDED. CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT 1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVELENT. GROUND ANCHOR REQUIREMENTS ARE 1@ EACH CORNER & ONE EVERY OTHER INTERIOR RAFTER POST LOCATION. AT A MAXIMUM 1U-0" O.C., AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR CONCRETE SLAB CONSTRUCTION. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS. PRODUCT APPROVAL: A c/l_..,ntrl r.Ov i i� vt_s_ �A nr FL i� 4�-R4 2 WALL PANEL FL14024-R3 3 (1) 3068 DOOR FL17996 4 (2) 9' X 8' ROLL -UP DOORS FL12765.8 NOTE: PRODUCT APPROVAL CODES PROVIDED BY OTHERS ZONE WIND PRESSURES DESIGN PRESSURE (PSF) POSITIVE NEGATIVE 1 15 -30 2 16 -46 3 21 -86 4 29 -32 5 32 -42 Engineer: Kent Bice FL License #: 50421 CO4#1 30468 all% M 1/i0s��A WANNEU �Jri►'� • n e ear �. `0 I� E N 3 �.,�cif, • • No 5042i ;*� STATE OF ►jj1�N M;r1yo 11/16/18 RECEIVED ft U) W U �D LL vr�^ r! J W W U) Q Q D m J J a F W U ° U_: W. _j w 3 w J ZN (n �= 8Q �� a0 U Z w U w W Uo -LLJ �LL,W a ❑ LL �� �z0> °L ow U mLL Uw Ott M Z O N Z w w UW � W 00 O J $ Q� s =y�8 O ii$; tSi 'NcN 0-0 OH LL d ZZ� Z 2 w(9� ZO yE�o C y�jyy a N W vw F YN Z OZ 0o Q w w W N� i'0 ZO 8 n = a O �a ion wa N m m N N - �w= a oo 0 Z ; 2 LLj O O V VNM (Y a w 2 F_ wJr- U �o� LL N O Oyes O W 0 W. O Few F aaz O r Wgo J J ww �N00 zoo Q O V K uJ d L =� gt Z UL<wozm w V :3 L Z W ZLL 0, wQ ,Z wE wHw o F- LL >wo wzOz JQO SHEET w 1 aF 6 0 Z ,,,,mjttjngqq Department fit, �.,ais counEv