Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE1 , t FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LP-03 Builder Name: Street: 1312 LONG PINE DR GA�14FM Permit Office: City, State, Zip: FT. PIERCE, FL, 34982 Permit Number: Owner: S� � ld COuT1W Jurisdiction: Design Location: FL, Fort Pierce l y 1 County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2342.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 2000.40 ftZ b. Frame - Wood, Adjacent R=11.0 342.22 ftZ 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2340.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2340.00 ft2 6. Conditioned floor area above grade (ft2) 2340 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(299.3 .sgft.) Description Area a. Sup: Main, Ret: Main, AH: Main 6 721 a. U-Factor: Dbl, U=0.62 299.34 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 42.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. 0-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (2340.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2340.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 15.E Credits Pstat Total Proposed Modified Loads: 70.79 Glass/Floor Area: 0.128 Total Baseline PASS Loads:' 79.54 I hereby certify that the plans and specifications covered by Review of the plans and STA?, this calculation are in compliance with the Florida Energy specifications covered by this p�TIiE 4 r' = O 'c+,O Code. calculation indicates compliance yn,,;'%' `-'° :.'.;,.•���„ with the Florida Energy Code. !. rrr„t:G�-;' PREPARED BY: Before construction is completed DATE: 04/11/2018 this building will be inspected for compliance with Section 553.908 _.. a i], 3._ d O-)j��l; ,a hereby certify that hii s b'n esi is in compliance Florida Statutes. with the Florida Energy Cod c0p y TIZ� OWNER/AGENT:_ BUILDING OFFICIAL: DATE: � DATE:'' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. 1 - Compliance requires an Air Barrier and Insulation Inspection Checklist in laccordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402.4.1.2). `,FILE COPY 4/11/2018 4:32 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1� Compliant Software Page 1 of 4 CORM R405-2017 PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: LP-03 Bedrooms: 5 User Conditioned Area: 2340 Total -Stories: 1 1 Worst Case: No Rotate Angle: 0 Cross Ventilation, No WholelHouse Fan: No Single-family New (From Plans) Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 1312 LONG PINE DR County: St. Lucie City, State, Zip: FT. PIERCE, FL, 34982 CLIMATE V Design Location Design Temp TMY Site I 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI I 39 90 70 75 299 62 Low I BLOCKS Number Name Area Volume 1 Block1 2340 21762 �I I SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main i 2340 21762 Yes 6 5 1 Yes Yes Yes FLOORS I # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 212 ft I 0 2340 ft2 ---- 0 0 1 ROOF V # Type Roof (Gable Roof Materials Area (Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Hip Composition shingles 2617 ft2 II ft2 Medium 0.45 N 0.9 No '20 26.6 ATTIC i / V # Type i Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented '0 2340 ft2 N N i CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 0 Blown 2340 ft2 0.1 Wood 4/11/2018 4:32 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 'I WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below �rnt- moo Wall�ype Space R-Value-Et-In Et-Ip Area R-Value- Erection -Absor -Grade%_ _ 1 N Exterior Concrete Block - Ext Insul Main, 4 54 4 9 4 507.1 ft2 0 0 0.3 0 2 E Exterior Concrete Block - Ext Insul Main; I 4 72 4 9 4 675.1 ft2 0 0 0.3 0 3 S Exterior Concrete Block - Ext Insul Main 4 40 0 9 4 373.3 ft2 0 0 0.3 0 _ 4 W Exterior Concrete Block - Ext Insul Main 4 47 8 9 4 444.9 ft2 0 0 0.3 0 _ 5 - Garage Frame - Wood Main I 11 36 8 9 4 342.2 ft' 0 0.25 0.3 0 I DOORS # Ornt Door Type Space I Storms U-Value Width Height Area Ft In Ft In 1 S Wood Main I None .39 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U,-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes I0.62 0.25 N 43.3 ft2 0 ft 0 in 0 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.25 N 52.0 ft' 0 ft 0 in 0 ft 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.25 N 72.0 ft' 0 ft 0 in 0 ft 0 in None None 4 e 2 Metal Double (Clear) Yes u.62 0.25 N 6.5 ft' 0 ft 0 in 0 ft 0 in None None 5 s 3 Metal Double (Clear) Yes 662 0.25 N 78.0 ftZ 0 ft 0 in 0 ft 0 in None None 6 s 3 Metal, Double (Clear) Yes 0'62 0.25 N 8.7 ft' 0 ft 0 in 0 ft 0 in None None 7 s 3 Metal Double (Clear) Yes 0.62 0.25 N 10.7 ft' 0 ft 0 in 0 ft 0 in None None 8 w 4 Metal Double (Clear) Yes 0.62 0.25 N 6.5 ft' 0 ft 0 in 0 ft 0 in None None 9 W 4 Metal Double (Clear) Yes I 0.62 0.25 N 21.7 ft' 0 ft 0 in 0 ft 0 in None None GARAGE I # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 494 ft2 494 ft' 1 64 ft 9.3 ft 1 INFILTRATION I # Scope Method SLA CFM 50 I ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000295 1813.5 99.56 187.23 .2157 5 HEATING SYSTEM I # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 4/11/2018 4:32 AM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 CORM R405-2017 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 42 kBtu/hr 1260 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF I Cap Use SetPnt Conservation 1 Electric None Garage ; 0.94 I 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC I Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None I �I ft2 I DUCTS ---- Supply --- -- Return ----I Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Main 6 721 ft2 Main 514 112 Default Leakage Main (Default) (Default) 1 1 TEMPERATi RES Programable Thermostat: Y Ceiling Fans: Cooling r Heatin[X] Jan r Feb Jan [X] Feb Mar Pq Mar r , Apr May II rX Jun X Jul [ j Appr May [ Jun Jul Au�Xj rj Aug Sep SeP Oct Oct Nov Nov H Dec HDec Ventin [[[ ]]] Jan [[[ ]]] Feb X Mar [[[XXX]]] A r [ Ma [[[ jjj Jun Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference I Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 �i 78 I 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 I 78 78 78 78 78 78 78 PM 78 78 78 78 78 I 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 II 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/11/2018 4:32 AM EnergyGauge® USA - FlaRes2017 Section I ;I I I I I R405.4.1 Clompliant Software I Page 4 of 4 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPe'rformance Index, the more efficient the home. 1312 LONG PINEDR, FT. PIERCE, FL, 34982 I 1. New construction or existing New (From Plans)I 9. Wall Types Insulation 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 b. Frame - Wood, Adjacent R=11.0 3. Number of units, if multiple family 1 c. N/A R= 4. Number of Bedrooms 5 I d. N/A R= 5. Is this a worst case? No I 10. Ceiling Types Insulation a. Roof Deck (Unvented) R=20.0 6. Conditioned floor area (ft2) 2340 I b. N/A R= 7. Windows" Description Area c. N/A R= a. U-Factor: Dbl, U=0.62 299.34 ft2 11. Ducts a. Sup: Main, Ret: Main, AH: Main SHGC: SHGC=0.25 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems c. U-Factor: N/A ft2 a. Central Unit SHGC: d. U-Factor: N/A ft2 SHGC: 13. Heating systems a. Electric Strip Heat Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 2340.00 ft2 a. Electric b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above qnergy saving features which will be installed (or exceeded) in this home before final inspecti n. Otherwise, a new EPL Display Card will be completed based on installed Code complia t features. Builder Signature: Address of New Home: Date: City -/FL -Zip: Area 2000.40 ft2 342.22 ft2 ft2 ft2 Area 2340.00 ft2 ft2 ft2 R ft2 6 721 kBtu/hr Efficiency 42.0 SEER:16.00 kBtu/hr Efficiency 34.0 COP:1.00 Cap: 50 gallons EF: 0.94 Pstat 01-T%E ST,gT� Ad y d *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web', site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I 4/11/2018 4:32 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 i -i- wrightsoft° Load Short Form Entire House I For: LP-03 1312 LONG PINE DR, FT. PIERCE, FL 34982 Htg Clg Outside db (°F) 43 91 Method Inside db (°F) 70 72 Construction quality I Design TD (°F) 27 19 I Fireplaces Daily range - L Inside humidity (%) 30 50 I Moisture difference (gr/lb) 0 65 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.5 kW I 29082 Btuh 19 °F 1383 cfm 0.048 cfm/Btuh 0 in H2O Job: Date: Apr 08, 2018 By: Infiltration Simplified Semi -tight 0 COOLING EQUIPMENT Make Carrier Trade 16 SEER PURON AC Cond CA16NA042****A Coil FV4CNB006 AHRI ref 4584928 Efficiency 13.7 EER, 16 SEER Sensible cooling 29050 Btuh Latent cooling 12450 Btuh Total cooling 41500 Btuh Actual air flow 1383 cfm Air flow factor 0.052 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.68 ROOM NAME Area (f(z) I Htg load (Btuh) II Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 240 114609 3427 219 178 HIS WIC 47 585 380 28 20 HER WIC 54 I 90 251 4 13 MASTER BATH 124 821 1064 39 55 BED 4 167 1803 2836 86 148 WEST HALL 83 -235 203 11 11 BATH 3 56 94 202 4 11 BED 5 WIC 23 39 145 2 8 BED 5 147 3039 2243 145 117 FOYER 63 1082 888 51 .46 BED 3 179 2332 2194 111 114 BED 2 179 3127 2238 149 116 BATH 2 55 9b5 739 47 38 PANTRY 28 48 259 2 13 UTILITY 52 87 613 4 32 FAST t-IAI I An -ie I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i + wrightSoft* Right -Suite® Universal 2012 12.1.05 RSU02818 ACC C:\Users\Jason\Documents\Wrightsoft HVACILP-03.rup Calc = MJ8 Front Door faces: i 2018-Apr-08 09:56:22 Page 1 KI I UHtN "13y '1301 '1 UZO 00 t UU DINING 210 ', 4604 2865 219 149 GREAT RM 449 ! 4062 4042 193 210 Entire House 2340 29087 26592 1383 1383 Other equip loads I 0 0 Equip. @ 0.95 RSM 25396 Latent cooling 12711 Tl A] n 1 nn A/1 1 1 nll/'f09 1 no4nn 1 Anon 1 Anon Calculations approved by ACCA to meet,all requirements of Manual J 8th Ed. - + wrightsoft' Rig ht-Suite® Universal 2012 12.1.05 RSU02818 Zt-& C:\UserslJasonlDocuments\Wrightsoft HVAC\LP-03.rup Calc = MJ8 Front Door faces: 2018-Apr-08 09:56:22 Page 2 + wrightsoft® i I Project Summary Entire House For: LP-03 1312 LONG PINE Notes: Weather: Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 26389 Btuh Ducts 2698 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 29087 Btuh Infiltration Method Construction quality Fireplaces Simplified Semi -tight 0 Job: Date: Apr 08, 2018 By: FT. PIERCE, FL 34982 Heating Cooling Area (ft2) 2340 2340 Volume (f?) 22208 22208 Air changes/hour 0.22 0.11 Equiv. AVF (cfm) 81 41 Heating Equipment Summary Beach Municipal AP, FL, US Summer Design Conditions Outside db 91 OF Inside db 72 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Sensible Cooling Equipment Load Sizing Structure 24878 Btuh Ducts 1715 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 25396 Btuh Latent Cooling Equipment Load Sizing Structure 10901 Btuh Ducts 1810 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 12711 Btuh Equipment total load 38106 Btuh Req. total capacity at 0.70 SHR i 3.0 ton Cooling Equipment Summary Make Make Carrier Trade Trade 16 SEER PURON AC Model Cond CA16NA042****A , AHRI ref Coil FV4CNB006 AHRI ref 4584928 Efficiency 100 EFF Efficiency 13.7 EER, 16 SEER Heating input 8.5 kW Sensible cooling 29050 Btuh Heating output 29082 Btuh Latent cooling 12450 Btuh Temperature rise 19 OF 'Total cooling 41500 Btuh Actual air flow 1383 cfm (Actual air flow 1383 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.052 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.68 Calculations approved by ACCA to meet'pll requirements of Manual J 8th Ed. A= + Wiilght5Oft' Rig htSuite®Universa1201212.1.05 RSU02818 i 2018-Apr-0809:56:22 .9M C:\Users\Jason\DocumentslWrightsoft HVAC\LP-03.rup Calc = MJ8 Front Door faces: S Page 1 10x10x8 10x10x7 178 CFM COV. PATIO 149 CFM DINING • • •■ ■• • MASTER SUITE 10x10x8 ■ 210 CFM ■ 16"x16" R.A.G. W/ 10"0 FLEX 8"o GREAT ROOM 7"� 4"� 6 x 6 x 4 ■ 20 CFM 4"0 13 CFM 0 ■ HIS WIC HER WIC 7"0 o "0 4" 10x10x ■ .10 x x 50 CFM I 1 100 CFM 6 x 6 x 5 15 C EXHAUST J 50 C 40 CFM 6"0 AHU-1 KITCHEN sT MASTER BATH 3.5 TON I I ■ ■ OO N 12"4 6 0 6x6x4 13 CFM 12"x12" 10"0 R.A.G. t0"0 ® 4"0 DRYER 4"0 BA 2 18"x18" EXHAUST FLEX R.A.G. PANTR ■ / 12"0 FLEX o EXHAUS ■ ■ , 10x10x7 148CFM 8 $ 6x6x5 O 1 F 36 CFM � 5"0 5"m _ — 6 x 6 x 5-- --__ -- ■- - 38 CFM6x6 O CU-1 ■ WORK AREA BEDROOM 4 A 46Cxs 6 F� 3. STORAGE 2 4"0 6 6 4 FOYER 12"x12" 9"o RA.G. W/ 8"0 12"x12" R.A.G. W/ 8"0 • 6 x 6 x 48C x FLEX FLEX • ��M/5t►. tr. 11 CFM 4- W - T-0 7"0 ■ 7"0 10x10x7 10x10x7 TWO BAY GARAGE ■ COV. ENTRY 114 CFM 116 CFM • BEDROOM 3 BEDROOM 2 1ox1ox7 117 CFM ■ BEDROOM 5 NOTE: ■ ■ ■ ■ ALL RETURNS SHALL HAVE DIRECT DUCTING TO RETURN AIR PLENUM BOX. " DO NOT SCALE PLANS ■■ ■ ■ ■■