HomeMy WebLinkAboutENERGY EFFICIENCY CODE1
, t
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LP-03
Builder Name:
Street: 1312 LONG PINE DR
GA�14FM
Permit Office:
City, State, Zip: FT. PIERCE, FL, 34982
Permit Number:
Owner:
S� � ld COuT1W Jurisdiction:
Design Location: FL, Fort Pierce
l y
1
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (2342.7 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 2000.40 ftZ
b. Frame - Wood, Adjacent
R=11.0 342.22 ftZ
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
5
d. N/A
R= ft2
5. Is this a worst case?
No
10. Ceiling Types (2340.0 sgft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2340.00 ft2
6. Conditioned floor area above grade (ft2)
2340
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(299.3 .sgft.) Description
Area
a. Sup: Main, Ret: Main, AH: Main
6 721
a. U-Factor: Dbl, U=0.62
299.34 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A
ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
42.0 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. 0-Factor: N/A
ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
0.000 ft.
Area Weighted Average SHGC:
0.250
14. Hot water systems
8. Floor Types (2340.0 sgft.)
Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 2340.00 ft2
b. Conservation features
EF: 0.940
b. N/A
R= ft2
None
c. N/A
R= ft2
15.E Credits
Pstat
Total Proposed Modified
Loads: 70.79
Glass/Floor Area: 0.128
Total Baseline
PASS
Loads:' 79.54
I
hereby certify that the plans and specifications covered by
Review of the plans and
STA?,
this calculation are in compliance with the
Florida Energy
specifications covered by this
p�TIiE
4 r' = O
'c+,O
Code.
calculation indicates compliance
yn,,;'%' `-'°
:.'.;,.•���„
with the Florida Energy Code.
!. rrr„t:G�-;'
PREPARED BY:
Before construction is completed
DATE:
04/11/2018
this building will be inspected for
compliance with Section 553.908
_..
a i], 3._ d
O-)j��l; ,a
hereby certify that hii s b'n esi is in compliance
Florida Statutes.
with the Florida Energy Cod
c0p y TIZ�
OWNER/AGENT:_
BUILDING OFFICIAL:
DATE:
�
DATE:''
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1. 1
- Compliance requires an Air Barrier and Insulation Inspection Checklist in laccordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402.4.1.2).
`,FILE COPY
4/11/2018 4:32 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1� Compliant Software Page 1 of 4
CORM R405-2017
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
LP-03 Bedrooms: 5
User Conditioned Area: 2340
Total -Stories: 1
1 Worst Case: No
Rotate Angle: 0
Cross Ventilation, No
WholelHouse Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 1312 LONG PINE DR
County: St. Lucie
City, State, Zip: FT. PIERCE,
FL, 34982
CLIMATE
V Design Location
Design Temp
TMY Site I 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce
FL VERO_BEACH_MUNI I 39 90
70
75 299 62 Low
I BLOCKS
Number
Name
Area Volume
1
Block1
2340 21762 �I
I SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
i
2340 21762 Yes 6
5
1 Yes Yes Yes
FLOORS
I
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 212 ft I 0
2340 ft2
---- 0 0 1
ROOF
V #
Type
Roof (Gable Roof
Materials Area (Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Hip
Composition shingles 2617 ft2 II ft2 Medium
0.45
N 0.9 No '20 26.6
ATTIC
i
/
V #
Type
i
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented '0 2340 ft2
N N
i
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Unvented) Main 0 Blown
2340 ft2 0.1 Wood
4/11/2018 4:32 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017
'I
WALLS
/
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
�rnt-
moo Wall�ype Space
R-Value-Et-In Et-Ip Area
R-Value- Erection -Absor -Grade%_
_ 1
N
Exterior Concrete Block - Ext Insul Main,
4 54 4 9
4 507.1 ft2
0
0 0.3
0
2
E
Exterior Concrete Block - Ext Insul Main;
I
4 72 4 9
4 675.1 ft2
0
0 0.3
0
3
S
Exterior Concrete Block - Ext Insul Main
4 40 0 9
4 373.3 ft2
0
0 0.3
0
_ 4
W
Exterior Concrete Block - Ext Insul Main
4 47 8 9
4 444.9 ft2
0
0 0.3
0
_ 5
-
Garage Frame - Wood Main
I 11 36 8 9
4 342.2 ft'
0
0.25 0.3
0
I DOORS
#
Ornt Door Type Space
I Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S Wood Main
I None
.39 3
7
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID Frame Panes NFRC
U,-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1
n 1 Metal Double (Clear) Yes
I0.62 0.25 N
43.3 ft2 0 ft 0 in
0 ft 0 in
None
None
2
n 1 Metal Double (Clear) Yes
0.62 0.25 N
52.0 ft' 0 ft 0 in
0 ft 0 in
None
None
3
n 1 Metal Double (Clear) Yes
0.62 0.25 N
72.0 ft' 0 ft 0 in
0 ft 0 in
None
None
4
e 2 Metal Double (Clear) Yes
u.62 0.25 N
6.5 ft' 0 ft 0 in
0 ft 0 in
None
None
5
s 3 Metal Double (Clear) Yes
662 0.25 N
78.0 ftZ 0 ft 0 in
0 ft 0 in
None
None
6
s 3 Metal, Double (Clear) Yes
0'62 0.25 N
8.7 ft' 0 ft 0 in
0 ft 0 in
None
None
7
s 3 Metal Double (Clear) Yes
0.62 0.25 N
10.7 ft' 0 ft 0 in
0 ft 0 in
None
None
8
w 4 Metal Double (Clear) Yes
0.62 0.25 N
6.5 ft' 0 ft 0 in
0 ft 0 in
None
None
9
W 4 Metal Double (Clear) Yes
I
0.62 0.25 N
21.7 ft' 0 ft 0 in
0 ft 0 in
None
None
GARAGE
I
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
494 ft2 494 ft'
1 64 ft
9.3 ft
1
INFILTRATION
I
#
Scope
Method SLA CFM 50 I ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000295
1813.5 99.56 187.23 .2157
5
HEATING SYSTEM
I
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1
34 kBtu/hr
1
sys#1
4/11/2018 4:32 AM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
CORM R405-2017
COOLING SYSTEM
#
System Type
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split SEER: 16
42 kBtu/hr
1260 cfm
0.7
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location EF I Cap
Use
SetPnt
Conservation
1
Electric
None
Garage ; 0.94 I 50 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
I
Collector
Storage
Cart
# Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
I �I
ft2
I DUCTS
---- Supply ---
-- Return ----I
Air
CFM 25 CFM25
HVAC #
V #
Location R-Value
Area
Location Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1
Main
6 721 ft2
Main 514 112 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATi RES
Programable Thermostat: Y
Ceiling Fans:
Cooling r
Heatin[X]
Jan r Feb
Jan [X] Feb
Mar
Pq Mar
r , Apr May II rX Jun X Jul
[ j Appr May [ Jun Jul
Au�Xj
rj Aug
Sep
SeP
Oct
Oct
Nov
Nov
H
Dec
HDec
Ventin [[[ ]]]
Jan [[[ ]]] Feb
X Mar
[[[XXX]]] A r [ Ma [[[ jjj Jun Jul
Aug
Se [X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
I Hours
Schedule Type
1
2 3 4 5 6
7
8 9
10
11
12
Cooling (WD)
AM
78
78 78 78 78 78
78
78 80
80
80
80
PM
80
80 78 78 �i 78 I 78
78
78 78
78
78
78
Cooling (WEH)
AM
78
78 78 78 78 I 78
78
78 78
78
78
78
PM
78
78 78 78 78 I 78
78
78 78
78
78
78
Heating (WD)
AM
66
66 66 66 66 68
68
68 68
68
68
68
PM
68
68 68 68 68 II 68
68
68 68
68
66
66
Heating (WEH)
AM
66
66 66 66 66 68
68
68 68
68
68
68
PM
68
68 68 68 68 68
68
68 68
68
66
66
4/11/2018 4:32 AM
EnergyGauge® USA - FlaRes2017 Section
I
;I
I
I
I
I
R405.4.1 Clompliant Software
I
Page 4 of 4
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 89
The lower the EnergyPe'rformance Index, the more efficient the home.
1312 LONG PINEDR, FT. PIERCE, FL, 34982
I
1. New construction or existing
New (From Plans)I
9. Wall Types
Insulation
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0
b. Frame - Wood, Adjacent
R=11.0
3. Number of units, if multiple family
1
c. N/A
R=
4. Number of Bedrooms
5 I
d. N/A
R=
5. Is this a worst case?
No I
10. Ceiling Types
Insulation
a. Roof Deck (Unvented)
R=20.0
6. Conditioned floor area (ft2)
2340 I
b. N/A
R=
7. Windows" Description
Area
c. N/A
R=
a. U-Factor: Dbl, U=0.62
299.34 ft2
11. Ducts
a. Sup: Main, Ret: Main, AH: Main
SHGC: SHGC=0.25
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
c. U-Factor: N/A
ft2
a. Central Unit
SHGC:
d. U-Factor: N/A
ft2
SHGC:
13. Heating systems
a. Electric Strip Heat
Area Weighted Average Overhang Depth:
0.000 ft.
Area Weighted Average SHGC:
0.250
8. Floor Types Insulation
Area
14. Hot water systems
a. Slab -On -Grade Edge Insulation R=0.0
2340.00 ft2
a. Electric
b. N/A R=
ft2
c. N/A R=
ft2
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above qnergy saving features which will be installed (or exceeded)
in this home before final inspecti n. Otherwise, a new EPL Display Card will be completed
based on installed Code complia t features.
Builder Signature:
Address of New Home:
Date:
City -/FL -Zip:
Area
2000.40 ft2
342.22 ft2
ft2
ft2
Area
2340.00 ft2
ft2
ft2
R ft2
6 721
kBtu/hr Efficiency
42.0 SEER:16.00
kBtu/hr Efficiency
34.0 COP:1.00
Cap: 50 gallons
EF: 0.94
Pstat
01-T%E ST,gT�
Ad y d
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web', site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I
4/11/2018 4:32 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
i
-i- wrightsoft° Load Short Form
Entire House
I
For: LP-03
1312 LONG PINE DR, FT. PIERCE, FL 34982
Htg Clg
Outside db (°F)
43
91 Method
Inside db (°F)
70
72 Construction quality
I
Design TD (°F)
27
19 I Fireplaces
Daily range
-
L
Inside humidity (%)
30
50 I
Moisture difference (gr/lb)
0
65
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
8.5
kW I
29082
Btuh
19
°F
1383
cfm
0.048
cfm/Btuh
0
in H2O
Job:
Date: Apr 08, 2018
By:
Infiltration
Simplified
Semi -tight
0
COOLING EQUIPMENT
Make Carrier
Trade 16 SEER PURON AC
Cond CA16NA042****A
Coil FV4CNB006
AHRI ref 4584928
Efficiency 13.7 EER, 16 SEER
Sensible cooling
29050
Btuh
Latent cooling
12450
Btuh
Total cooling
41500
Btuh
Actual air flow
1383
cfm
Air flow factor
0.052
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat ratio
0.68
ROOM NAME
Area
(f(z)
I
Htg load
(Btuh) II
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
MASTER SUITE
240
114609
3427
219
178
HIS WIC
47
585
380
28
20
HER WIC
54
I 90
251
4
13
MASTER BATH
124
821
1064
39
55
BED 4
167
1803
2836
86
148
WEST HALL
83
-235
203
11
11
BATH 3
56
94
202
4
11
BED 5 WIC
23
39
145
2
8
BED 5
147
3039
2243
145
117
FOYER
63
1082
888
51
.46
BED 3
179
2332
2194
111
114
BED 2
179
3127
2238
149
116
BATH 2
55
9b5
739
47
38
PANTRY
28
48
259
2
13
UTILITY
52
87
613
4
32
FAST t-IAI I
An
-ie
I
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
i + wrightSoft* Right -Suite® Universal 2012 12.1.05 RSU02818
ACC C:\Users\Jason\Documents\Wrightsoft HVACILP-03.rup Calc = MJ8 Front Door faces: i
2018-Apr-08 09:56:22
Page 1
KI I UHtN
"13y
'1301
'1 UZO
00
t UU
DINING
210 ',
4604
2865
219
149
GREAT RM
449 !
4062
4042
193
210
Entire House
2340
29087
26592
1383
1383
Other equip loads
I 0
0
Equip. @ 0.95 RSM
25396
Latent cooling
12711
Tl A] n
1 nn A/1
1 1 nll/'f09
1 no4nn
1 Anon
1 Anon
Calculations approved by ACCA to meet,all requirements of Manual J 8th Ed.
- + wrightsoft' Rig ht-Suite® Universal 2012 12.1.05 RSU02818
Zt-& C:\UserslJasonlDocuments\Wrightsoft HVAC\LP-03.rup Calc = MJ8 Front Door faces:
2018-Apr-08 09:56:22
Page 2
+ wrightsoft®
i
I
Project Summary
Entire House
For: LP-03
1312 LONG PINE
Notes:
Weather:
Winter Design Conditions
Outside db
43
OF
Inside db
70
OF
Design TD
27
OF
Heating Summary
Structure
26389
Btuh
Ducts
2698
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
29087
Btuh
Infiltration
Method
Construction quality
Fireplaces
Simplified
Semi -tight
0
Job:
Date: Apr 08, 2018
By:
FT. PIERCE, FL 34982
Heating
Cooling
Area (ft2)
2340
2340
Volume (f?)
22208
22208
Air changes/hour
0.22
0.11
Equiv. AVF (cfm)
81
41
Heating Equipment Summary
Beach Municipal AP, FL, US
Summer Design Conditions
Outside db
91
OF
Inside db
72
OF
Design TD
19
OF
Daily range
L
Relative humidity
50
%
Moisture difference
65
gr/lb
Sensible Cooling Equipment Load Sizing
Structure
24878
Btuh
Ducts
1715
Btuh
Central vent (0 cfm)
0
Btuh
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipment sensible load
25396
Btuh
Latent Cooling Equipment Load Sizing
Structure
10901
Btuh
Ducts
1810
Btuh
Central vent (0 cfm)
0
Btuh
Equipment latent load
12711
Btuh
Equipment total load
38106
Btuh
Req. total capacity at 0.70 SHR
i
3.0
ton
Cooling Equipment Summary
Make
Make Carrier
Trade
Trade 16 SEER PURON AC
Model
Cond CA16NA042****A ,
AHRI ref
Coil FV4CNB006
AHRI ref 4584928
Efficiency
100 EFF
Efficiency 13.7 EER, 16 SEER
Heating input
8.5 kW
Sensible cooling
29050
Btuh
Heating output
29082 Btuh
Latent cooling
12450
Btuh
Temperature rise
19 OF
'Total cooling
41500
Btuh
Actual air flow
1383 cfm
(Actual air flow
1383
cfm
Air flow factor
0.048 cfm/Btuh
Air flow factor
0.052
cfm/Btuh
Static pressure
0 in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.68
Calculations approved by ACCA to meet'pll requirements of Manual J 8th Ed.
A= + Wiilght5Oft'
Rig htSuite®Universa1201212.1.05 RSU02818
i
2018-Apr-0809:56:22
.9M C:\Users\Jason\DocumentslWrightsoft HVAC\LP-03.rup Calc = MJ8 Front Door faces: S
Page 1
10x10x8
10x10x7
178 CFM
COV. PATIO
149 CFM
DINING
•
•
•■
■• •
MASTER SUITE
10x10x8
■
210 CFM
■
16"x16"
R.A.G.
W/ 10"0
FLEX
8"o
GREAT ROOM 7"�
4"� 6 x 6 x 4
■
20 CFM 4"0 13 CFM
0
■
HIS WIC
HER WIC
7"0
o
"0
4"
10x10x
■
.10
x x
50 CFM
I 1
100 CFM
6
x 6 x 5
15 C
EXHAUST
J
50 C
40 CFM 6"0
AHU-1
KITCHEN
sT
MASTER BATH
3.5 TON
I
I
■
■
OO
N
12"4
6 0
6x6x4
13 CFM
12"x12"
10"0
R.A.G. t0"0
®
4"0 DRYER
4"0
BA 2
18"x18"
EXHAUST
FLEX R.A.G.
PANTR
■
/ 12"0
FLEX
o
EXHAUS
■ ■
,
10x10x7
148CFM
8
$
6x6x5
O
1
F
36 CFM �
5"0 5"m
_ — 6 x 6 x 5--
--__
--
■-
-
38 CFM6x6
O
CU-1
■
WORK AREA
BEDROOM 4
A
46Cxs
6 F�
3.
STORAGE
2
4"0
6 6
4
FOYER
12"x12"
9"o RA.G.
W/ 8"0
12"x12"
R.A.G.
W/ 8"0
•
6 x 6 x 48C
x
FLEX
FLEX
•
��M/5t►. tr.
11 CFM
4-
W
-
T-0
7"0
■
7"0
10x10x7
10x10x7
TWO BAY GARAGE
■
COV. ENTRY
114 CFM
116 CFM
•
BEDROOM 3
BEDROOM 2
1ox1ox7
117 CFM
■
BEDROOM 5
NOTE:
■ ■
■ ■
ALL RETURNS SHALL HAVE DIRECT
DUCTING
TO RETURN AIR PLENUM BOX.
"
DO
NOT SCALE PLANS
■■ ■
■ ■■