HomeMy WebLinkAboutENGINEERING0ounty (This appendix is not part of this standard. it conformance to the standard. It has not been contain material that has not been subject to pi material are not offered the right to appeal to, APPENDIX A RECOMMENDED ASHRAEIACCA COMP Building or Zone Name: HARBOUR RIDGE LIFES Location or Address: 12600 HARBOUR RIDGE Design Conditions: Weather Data Used Indoor Dry Bulb Design Temperature Indoor Design Relative Humidity merely informative and does not contain requirements necessary for )cessed according to the ANSI requirements for a standard and may is review or a consensus process. Unresolved objectors on informative BRAE or ANSI) FORM FOR STANDARD 183 CENTER VD, PALM CITY, FL Cooling WPB, FL (92DB/79WB) 3°F 0%RH Load Calculation Method: (indicate which of the following methods is used) ❑ CLTD/CLF—Cooling Load Temperature ❑ B—Heat Balance methods 0T ETD?A—Total Equivalent Temperatui ❑ TFNt—Transfer Function Methods ❑ RTS—Radiant Time Series methods ❑ OTHER (please specify) The undersigned attests that the above l used to perform t'lgq%IAachWh9lations cc % •%�t.1P E ��� Signed: C15 ��ll • �� �i r • � r • a : W ;J 20 �, a • LIJ Submitted by ��0 :% yA� O • Q. Heating WPB, FL (45DB) 680F 45%RH Load Factor methods Difference/Time Averaging methods C Q `� c at t e procedures with ANSUASHRAEIACCA Standard 183. Date: L Date: v AL ANSUASHRAF+ACCA Standard 183-2007 15-1039 `,��ttttttiri��i v�G E N 3F•• . 0 0 aft 0: No 31932 •A •CC � 1 • �'. STATE OF ll��/.� RGD Consulting Engineers; Inc. 1232 W. Indiantown Road, Suite 104 Jupiter, FL 33458 P.'"561-743-0165 F 561-743-0193 C A# 5454 —Qr Location Building owner Program user Company Comments Palm City, Florida RGD & Associates Inc RGD & Associates Inc By RGD Dataset name X:l Active_Projects115-1039 Harbour Ridge Lifestyle CenterlMEP_ProjectlMechanicallEnergy Code\HARBOUR RIDGE nrg.TRC Calculation time 09:54 AM on 10/13/2015 TRACED 700 version 6.3.2 Location West Palm Beach, Florida Latitude 26.7 deg Lon itude 80.2 deg Time Zone 5 Elevation 15 ft Barometric pressure 29.9 in. Hg Air density 0.0760 lb/cu ft Air specific heat 0.2444 Btu/Ib-°F Density -specific heat product 1.1147 Btu/h-cfm-°F Latent heat factor 4,906.9 Btu-min/h•cu ft Enthalpy factor 4.5604 lb-min/hr-cu ft Summer design dry bulb 92.3 OF Summer design wet bulb 79.2 OF Winter design dry bulb 45.0 OF Summer clearness number 0.90 Winter clearness number 0.95 Summer ground reflectance 0.20 Winter ground reflectance 0.20 Carbon Dioxide Level 400 ppm Design simulation period January - December Cooling load methodology TETD-TA1 Heating load methodology UATD 7M(X7oo .ft_ gas T..building analysts Zone Checksums By RGD Zone - 001 COOLING COIL PEAK Peaked at Time: Mo/Hr: 11 / 16 Outside Air: OADBMIB/HR: 82 / 70 / 90 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h (%) Envelope Loads Skylite Solar 0 0 0 0. Skylite Cond 0 0 0 0: Roof Cond 0 8,329 8,329 6 ; CLG SPACE PEAK Mo/Hr. 11 / 16 OADB: 82 Space Percent Sensible Of Total Btu/h (%) : : Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 ; Roof Cond HEATING COIL PEAK Mo/Hr. Heating Design OADB: 45 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 0 -3,180 Percent Of Total (%) 0.00 0.00 8.61 TEMPERATURES Cooling SADB 54.0 Ra Plenum 73.0 Return 73.0 ReUOA 73.0 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 68.0 67.4 67.4 67.5 0.0 0.0 0.0 Glass Solar 61,994 0 61,994 44 : 64,001 56 ; Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 6,359 0 6,359 5 : 5,025 4 : Glass/Door Cond -12,001 -12,001 32.49 Cooling Heating Wall Cond 2,384 1,315 3,699 3 ; 2,163 2: Wall Cond -1,944 -3,110 8.42 Partition/Door 0 . 0 0: 0 0: Partition/Door 0 0 0.00 Diffuser 6,408 6,408 Floor 0 0 0: 0 0 Floor 0 0 0.00 Terminal 6,408 6,408 Adjacent Floor 0 0 0 0 ; 0 0 ; Adjacent Floor 0 0 0.00 Main Fan 6,408 6,408 Infiltration 0 0 0. 0 0: Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 70,737 9,644 80,381 58 : 71,189 62 ; Sub Total ==> -13,945 -18,291 49.51 Nom Vent 1,297 1,297 AHU Vent 1,297---l-,297- Internal Loads ; Internal Loads Infil 0 0 Lights 17,322 0 17,322 12: 17,379 15=Lights 17,322 17,322 -46.89 MinStop/Rh 0 0 People 27,737 0 27-737 2 ,868 12: People 13,868 13,868 -37.54 Return 6,408 6,408 _Misc 7,608 0 7,608 5: 7,608 7: Misc 7,608 7,608 -20.59 Exhaust 1,297 1,297 Sub Total ==> 52,666 0 52,666 38 38,798 34 ; Sub Total ==> 38,798 38,798 -105.02 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 4,505 -4.505 0 0 : 4,310 4 : Ceiling Load -987 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 9,557 7 0 0: Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0. 0 0 ; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr sizing 0 0 01 0 0 Exhaust Heat 938 -2.54 ENGINEERING CKS Exhaust Heat -4,280 -4,280 -3: OA Preheat Diff. -33,245 89.99 Sup. Fan Heat 1,234 1 : RA Preheat Diff. -23,865 64.60 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 20.2 20.2 Duct Heat Pkup 0 0 0: ; System Plenum Heat -1,278 3.46 cfm/ft2 1.33 1.33 Underflr Sup Ht Pkup 0 0: Underflr Sup Ht Pkup 0 0.00 cfm/ton 297.77 Supply Air Leakage 0 0 0: Supply Air Leakage 0 0.00 ft2/ton 223.08 Btu/heft' 53.79 -7.69 Grand Total =_> 127,908 859 139,558 100.00 114,297 100.00 Grand Total ==> 23,865 -36,943 100.00 No. People 50 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F grAb Main Clg 11.6 139.6 120.5 6,408 73.0 60.1 57.3 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 9.9 118.7 55.4 1,297 92.3 79.2 130.2 Total 21.5 258.3 Leave DBIWB/HR °F °F gr4b 53.8 52.4 56.6 0.0 0.0 0.0 54.0 53.9 62.0 AREAS Gross Total Glass ft2 (%) Floor 4,801 Part 0 Int Door 0 ExFlr 0 Roof 4,801 0 0 Wall 3,443 1,037 30 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F n Htg -3.7 6,408 67.5 68.0 Htg 0.0 0 0.0 0.0 heat 0.0 0 0.0 0.0 nidif 0.0 0 0.0 0.0 Vent -33.2 1.297 45.0 68.0 3/ -36.9 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative -1 System Checksums Report Page 1 of 15 Zone Checksums By RGD Zone - 002 COOLING COIL PEAK Peaked at Time: Mo/Hr: 6 / 19 Outside Air: OADBI B/HR: 85 / 74 / 110 Space Plenum Net Percent: Sens. + Lat Sens. + Lat Total Of Total ; Btu/h Btu/h Btu/h (%): Envelope Loads Skylite Solar 0 0 0 0: Skylite Cond 0 0 0 0: Roof Cord 0 957 957 4 ; CLG SPACE PEAK Mo/Hr: 6 / 19 OADB: 85 Space Percent: Sensible Of Total ; Btu/h (%) : : Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 Roof Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 45 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 0 -405 Percent Of Total (%) 0.00 0.00 2.91 TEMPERATURES Cooling SADB 54.0 Ra Plenum 72.9 Return 72.9 Ret/OA 73.0 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 68.0 67.4 67.4 67.7 0.0 0.0 0.0 Glass Solar 3,927 0 3,927 17 : 3,927 23 ; Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 705 0 705 3 : 705 4 : Glass/Door Cond -926 -926 6.66 Cooling Heating Wall Cond 419 191 610 3 ; 419 2 Wall Cond -242 -364 2.62 Partition/Door 0 0 0: 0 0 Partition/Door 0 0 0.00 Diffuser 1,097 1,097 Floor 0 0 0: 0 0 Floor 0 0 0.00 Terminal 1,097 1,097 Adjacent Floor 0 0 0 0: 0 0 ; Adjacent Floor 0 0 0.00 Main Fan 1,097 1,097 Infiltration 0 0 0; 0 0: Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 5,051 1,149 6,199 26: 5,051 29 : Sub Total ==> -1,168 -1,696 12.19 Nom Vent 526 526 AHU Vent 526 526- Internal Loads ; Internal Loads - lnfil 0 0 Lights 1,880 0 1,880 8. 1,880 11 ; Lights 1,880 1,880 -13.52 MinStop/Rh 0 0 People 13,464 0 13,464 57�--6-732 39 People 6,732 6,732 -48.41 Return 1,097 1,097 Misc 2,5jW�- 0 2,507 11: 2,507 15: Misc 2,507 2,507 -18.02 Exhaust 526 526 -Sub-Total==> 17,850 0 17,850 75 : 11,118 65 ; Sub Total ==> 11,118 11,118 -79.95 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 954 -954 0 0: 954 6 : Ceiling Load -126 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 2,366 10: 0 0 Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 : 0 0 ; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0: : Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0: 0 0 Exhaust Heat 381 -2.74 ENGINEERING CKS Exhaust Heat -2,886 -2,886 -12 : OA Preheat Diff. -13,494 97.03 Sup. Fan Heat 211 1 : RA Preheat Diff. -9,824 70.64 Cooling Heating Ret. Fan Heat 0 0 0. ; Additional Reheat 0 0.00 % OA 48.0 48.0 Duct Heat Pkup 0 0 0: ; System Plenum Heat -392 2.82 cfm/ft2 1.79 1.79 Underfir Sup Ht Pkup 0 0: Underfr Sup Ht Pkup 0 0.00 cfm/ton 183.07 Supply Air Leakage 0 0 0: ; Supply Air Leakage 0 0.00 ft'/ton 102.11 Btu/hr-ft2 117.52 -22.72 Grand Total =_> 23,855 -2,691 23,741 100.00' 17,123 100.00 ' Grand Total =_> 9',824 -13,907 100.00 No. People 24 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F grAb Main Clg 2.0 23.7 17.6 1,097 73.0 61.4 62.8 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 4.0 48.2 22.5 526 92.3 79.2 130.2 Total 6.0 71.9 Leave DB/WB/HR °F °F grAb 53.8 53.8 61.8 0.0 0.0 0.0 54.0 53.9 62.0 AREAS Gross Total Glass ft2 (%) Floor 612 Part 0 Int Door 0 ExFlr 0 Roof 612 0 0 Wall 362 80 22 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F i Htg -0.4 1,097 67.7 68.0 Htg 0.0 0 0.0 0.0 seat i 0.0 0 0.0 0.0 tidif 0.0 0 0.0 0.0 Vent -13.5 526 45.0 68.0 1/ -13.9 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative -1 System Checksums Report Page 2 of 15 Zone Checksums By RGD Zone - 003 COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK Peaked at Time: Mo/Hr: 7 / 15 Mo/Hr: 7 / 19 Mo/Hr: Heating Design Outside Air: OADB/WB/HR: 91 / 78 / 124 OADB:-87 OADB: 45 Space Plenum Net Percent: Space Percent Space Peak Coil Peak Percent Sens. + Lat. Sens. + Lat Total Of Total ; Sensible Of Total ; Space Sens Tot Sens Of Total Btu/h Btu/h Btu/h (%): Btu/h (%) : Btu/h Btu/h (%) Envelope Loads : Envelope Loads Skylite Solar 0 0 0 0: 0 0: Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0: 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 4,946 4,946 21 : 0 0 Roof Cond 0 -1',227 14.16 Glass Solar 3,580 0 3,580 16. 3,644 22 . Glass Solar 0 0 0.00 Glass/DoorCond 1,131 0 1,131 5. 1,108 7: Glass/DoorCond -1,753 -1,753 20.23 Wall Cond 237 199 436 2 : 226 1 : Wall Cond -146 -267 3.08 Partition/Door 0 0 0: 0 0: Partition/Door 0 0 0.00 Floor 0 0 0: 0 0 Floor 0 0 0.00 Adjacent Floor 0 0 0 0; 0 0; Adjacent Floor 0 0 0.00 Infiltration 0 0 0 0 j 0: Infiltration 0 0 0.00 Sub Total =_> 4,948 5,145 10,093 44: 4,978 30 ; Sub Total ==> -1,899 -3,247 37.47 Internal Loads ; Internal Loads Lights 7,130 0 7,130 31 ; 7,130 4.4_�__L-ight 7,130 7,130 -82.29 People 2,200 0 2,200 10. 1,100 7: People 1,100 1,100 -12.69 Misc - _-- -2;685 0 2,685 12 : 2,685 16 : Misc 2,685 2,685 30.99 - -- _ Sub Total ==> 12,016 0 12,016 52. 10,916 67 Sub Total ==> 10,916 10,916 -125.97 Ceiling Load 512 -512 0 0: 491 3 : Ceiling Load -381 0 0.00 Ventilation Load 0 0 1,050 5: 0 0 Ventilation Load 0 0 0.00 Adj Air Trans Heat 0 0 0 ; 0 0 ; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing -12,563 -12,563 144.98 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 121 -1.40 Exhaust Heat -289 -289 -1 : OA Preheat Diff. -4,291 49.52 Sup. Fan Heat 151 1 • RA Preheat Diff. 0 0.00 Ret. Fan Heat 0 0 0: ; Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0: ; System Plenum Heat 398 4.60 Underflr Sup Ht Pkup 0 0: UnderflrSup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0: ; Supply Air Leakage 0 0.00 Grand Total ==> 17,476 4,344 23,021 100.00' 16,385 100.00 ' Grand Total ==> -3,927 -8,665 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBIWB/HR ton MBh MBh cfm °F °F gr/lb Main Clg 1.9 23.0 21.0 786 73.4 60.0 56.1 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 1.3 15.3 7.2 167 92.3 79.2 130.2 Total 3.2 38.3 Leave DBIWB/HR °F °F gr/lb 53.8 49.4 45.4 0.0 0.0 0.0 54.0 53.9 62.0 AREAS Gross Total Glass ft' (%) Floor 1,852 Part 0 Int Door 0 ExFlr 0 Roof 1,852 0 0 Wall 359 151 42 Ext Door 0 0 0 TEMPERATURES Cooling Heating SADB 54.0 72.5 Ra Plenum 73.7 67.4 Return 73.6 67.4 Ret/OA 73.4 67.5 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.1 0.0 AIRFLOWS Cooling Heating Diffuser 786 786 Terminal 786 786 Main Fan 786 786 Sec Fan 0 0 Nom Vent 167 167 AHU Vent 167 167 Infil 0 0 MinStop/Rh 0 0 Return 786 786 Exhaust 167 167 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % OA 21.3 21.3 cfm/ft' 0.42 0.42 cfm/ton 246.09 ftl/ton 579.63 Btu/heft' 20.70 -4.68 No. People 4 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F n Htg A.4 786 67.5 Htg 0.0 0 0.0 heat 0.0 0 0.0 nidif 0.0 0 0.0 Vent A.3 167 45.0 V -8.7 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative -1 System Checksums Report Page 3 of 15 Zone Checksums By RGD Zone - 004 COOLING COIL PEAK Peaked at Time: Mo/Hr: 8 / 15 Outside Air: OADBMIB/HR: 92 / 79 / 130 Space Plenum Net Percent: Sens. + Lat. Sens. + Lat Total Of Total ; Btu/h Btu/h Btu/h (%): Envelope Loads Skylite Solar 0 0 0 0: Skylite Cond 0 0 0 0: Roof Cond 0 4,287 4,287 10 ; CLG SPACE PEAK Mo/Hr: 8 / 16 OADB: 92 Space Percent Sensible Of Total ; Btu/h (%) : Envelope Loads 0 0 Skylite Solar 0 0: Skylite Cond 0 0 Roof Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 45 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 0 -1,027 Percent Of Total (%) 0.00 0.00 10.49 TEMPERATURES Cooling SADB 54.0 Ra Plenum 73.7 Return 73.7 Ret/OA 73.6 Fn MtrTD 0.0 Fin BIdTD 0.0 Fin Frict 0.1 Heating 68.0 67.4 67.4 67.5 0.0 0.0 0.0 Glass Solar 0 0 0 0; 0 0: Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0. 0 0: Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 705 252 957 2: 718 2: Wall Cond -421 -570 5.82 Partition/Door 0 0 0: 0 0: Partition/Door 0 0 0.00 Diffuser 1,882 1,882 Floor 0 0 0: 0 0: Floor 0 0 0.00 Terminal 1,882 1,882 Adjacent Floor 0 0 0 0. 0 0 ; Adjacent Floor 0 0 0.00 Main Fan 1,882 1,882 Infiltration 0 0 0: 0 0; Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 705 4,539 5,245 12 ; 718 2 : Sub Total ==> -421 -1,597 16.31 Nom Vent 338 338 Internal Loads AHU Vent 338-338- Internal Loads ; Infi 0 0 Lights 5,068 0 5,068 12 ; 5,068 14 : Lights 5,068 5,068 -51.78 MinStop/Rh 0 0 People 8,306 0 8,306 194- -427812People 4,278 4,278 -43.71 Return 1,882 1,882 Misc 23,051_- ----0---23,651 54 • 23,651 67 : Misc 23,651 23,651 -241.64 Exhaust 338 338 __ l =_> -Sub-Tdta 37,024 0 37,024 85 ; 32,996 94 : Sub Total ==> 32.996 32,996 -337.12 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 1,411 -1,411 0 0: 1,406 4 : Ceiling Load -319 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 2,396 5: 0 0: Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0. 0 0 ; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0. : Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0: 0 0 : Exhaust Heat 245 -2.50 ENGINEERING CKS Exhaust Heat -1,238 -1,238 -3 : : OA Preheat Diff. -8,671 88.59 Sup. Fan Heat 362 1 • RA Preheat Diff. -32,256 329.56 Cooling Heating Ret. Fan Heat 0 0 0. ; Additional Reheat 0 0.00 % OA 18.0 18.0 Duct Heat Pkup 0 0 0 : ; System Plenum Heat -504 5.15 cfm/ft' 1.21 1.21 Undertir Sup Ht Pkup 0 0. : Underflr Sup Ht Pkup 0 0.00 cfm/ton 302.06 Supply Air Leakage 0 0 0: : Supply Air Leakage 0 0.00 ft'/ton 248.84 Btu/heft' 48.22 -6.31 Grand Total ==> 39,140 1,891 43,789 100.00' 35,120 100.00 ' Grand Total ==> 32,256 -9,788 100.00 No. People 16 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/lb Main Clg 3.7 43.8 38.3 1,882 73.6 60.3 57.1 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 2.6 31.0 14.4 338 92.3 79.2 130.2 Total 6.2 74.8 Leave DB/WB/HR °F °F gr4b 53.8 52.1 55.2 0.0 0.0 0.0 54.0 53.9 62.0 AREAS Gross Total Glass Floor 1,550 Part 0 Int Door 0 ExFlr 0 Roof 1,550 0 0 Wall 440~ 0 0 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F i Htg -1.1 1,882 67.5 Htg 0.0 0 0.0 seat 0.0 0 0.0 iidif 0.0 0 0.0 Vent -8.7 338 45.0 i/ -9.8 0.01 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative-1 System Checksums Report Page 4 of 15 Zone Checksums By RGD Zone - 005 COOLING COIL PEAK Peaked at Time: Mo/Hr: 8 / 15 Outside Air: OADBMIB/HR: 92 / 79 / 130 Space Plenum Net Percent: Sens. + Lat. Sens. + Lat Total Of Total ; Btu/h Btu/h Btu/h (%) : Envelope Loads : Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0: Roof Cond 0 7,397 7,397 33 ; CLG SPACE PEAK Whir: 8 / 16 OADB: 92 Space Percent Sensible Of Total ; Btu/h (%) : Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 ; Roof Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 45 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 0 -1,774 Percent Of Total (%) 0.00 0.00 22.99 TEMPERATURES Cooling SADB 54.0 Ra Plenum 73.7 Return 73.7 Ret/0A 73.4 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 70.0 67.4 67.4 67.6 0.0 0.0 0.0 Glass Solar 0 0 0 0; 0 0; Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0: 0 0: Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 937 336 1,273 6 : 955 7: Wall Cond -576 -780 10.11 Partition/Door 0 0 0: 0 0 Partition/Door 0 0 0.00 Diffuser 614 614 Floor 0 0 0: 0 0 Floor 0 0 0.00 Terminal 614 614 Adjacent Floor 0 0 0 0 ; 0 0 Adjacent Floor 0 0 0.00 Main Fan 614 614 Infiltration 0 0 0: 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 937 7,733 8,671 38 : 955 7 : Sub Total ==> -576 -2,554 33.09 Nom Vent 237 237 AHU Vent 237 237- Internal Loads Internal Loads -Infil 0 0 Lights 7,866 0 7,866 35 ; 7,866 61 Light 7,866 7,866 -101.94 MinStop/Rh 0 0 People 4,651 0 4,651 20-�-2;461 19: People 2,461 2,461 -31.89 Return 614 614 Misc 11097 -0-1,097 5: 1,097 8: Misc 1,097 1,097 -14.21 Exhaust 237 237 Sub Total ==> 13,614 0 13,614 60 ; 11,423 88 ; Sub Total ==> 11,423 11,423 -148.04 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 622 -622 0 0: 615 5 : Ceiling Load -551 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 491 2: 0 0 Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 ; 0 0 ; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0: :Ov/Undr Sizing -11,665 -11,665 151.17 Ov/Undr Sizing 0 0 0: 0 0 Exhaust Heat 171 -2.22 ENGINEERING CKS Exhaust Heat -197 A97 -1 OA Preheat Diff. -6,076 78.74 Sup. Fan Heat 118 1 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 38.6 38.6 Duct Heat Pkup 0 0 0 : System Plenum Heat 983 -12.74 cfm/ft' 0.23 0.23 UnderflrSup HtPkup 0 0: : UnderflrSup HtPkup 0 0.00 cfm/ton 165.85 Supply Air Leakage 0 0 0. : Supply Air Leakage 0 0.00 ft'/ton 723.89 Btu/heft' 16.58 -2.88 Grand Total ==> 15,173 6,914 22,696 100.00 12,993 100.00 ' Grand Total ==> -1,368 -7,717 100.00 No. People 9 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/Ib Main Clg 1.9 22.7 20.0 614 73.4 61.0 60.2 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 1.8 21.7 10.1 237 92.3 79.2 130.2 Total 3.7 44.4 Leave DB/WB/HR 'F -F gr/lb 53.8 47.5 38.7 0.0 0.0 0.0 54.0 53.9 62.0 AREAS Gross Total Glass fts Floor 2,678 Part 0 Int Door 0 ExFlr 0 Roof 2,678 0 0 Wall 602 0 0 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F i Htg -1.6 614 67.6 Htg 0.0 0 0.0 seat 0.0 0 0.0 ddif 0.0 0 0.0 Vent -6.1 237 45.0 1/ -7.7 0.0 0.0 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative - 1 System Checksums Report Page 5 of 15 Zone Checksums By RGD Zone - 006 COOLING COIL PEAK Peaked at Time:. Mo/Hr: Outside Air: OADBf B/HR: Space Plenum Sens. + Lat. Sens. + Lat Btu/h Btu/h Envelope Loads Skylite Solar 0 0 Skylite Cond 0 0 Roof Cond 0 1,921 12 / 11 75 / 65 / 76 Net Percent: Total Of Total Btu/h (%) : 0 0: 0 0: 1,921 4; CLG SPACE PEAK Mo/Hr: 11 / 10 OADB: 75 Space Percent: Sensible Of Total ; Bluth (%) : : Envelope Loads 0 0 : Skylite Solar 0 0 Skylite Cond 0 0 Roof Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 45 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 0 -1,321 Percent Of Total (%) 0.00 0.00 6.74 TEMPERATURES Cooling SADB 54.0 Ra Plenum 72.3 Return 72.1 Ret/OA 72.3 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 72.5 67.4 67.4 67.5 0.0 0.0 0.0 Glass Solar 22,506 0 22,506 46 : 22,831 56 ; Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 793 0 793 2 : 1,104 3 : Glass/Door Cond -6,496 -6,496 33.15 Cooling Heating Wall Cond 1,761 817 2,579 5 : 2,060 5: Wall Cond -2,023 -3,037 15.50 Partition/Door 0 0 0: 0 0: Partition/Door 0 0 0.00 Diffuser 1,915 1,915 Floor 0 0 0: 0 0 Floor 0 0 0.00 Terminal 1,915 1,915 Adjacent Floor 0 0 0 0 ; 0 0 ; Adjacent Floor 0 0 0.00 Main Fan 1,915 1,915 Infiltration 0 0 0: 0 0: Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 25,060 2,739 27,799 57: 25,995 64 ; Sub Total ==> -8,518 -10,854 55.39 Nom Vent 345 345 AHU Vent 345 345 Internal Loads ; Internal Loads -fnfi 0 0 Lights 7,053 0 7,053 14 : 7,053 17 Lights ;0 3 7,053 -35.99 MinStop/Rh 0 0 People 9,967 0 9,967 20: 5417-13 People 5,417 5,417 27.64 Return 1,915 1,915 Misc 2,558 0 2,558-5-�-- 2,558 6 : Misc 2,558 2,558 -13.05 Exhaust 345 345 Sub Total ==> _ _- 19;578 0 19,578 40. 15,028 37 Sub Total ==> 15,028 15,028 -76.69 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load -419 419 0 0 : -472 -1 Ceiling Load -410 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 1,111 2. 0 0: Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0, 0 0 ; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0: : Ov/Undr Sizing -15,708 -15,708 80.16 OvlUndr Sizing 0 0 0: 0 0 : Exhaust Heat 250 -1.27 ENGINEERING CKS Exhaust Heat 337 337 1 : : OA Preheat Diff. -8,850 45.17 Sup. Fan Heat 369 1 : RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0: Additional Reheat 0 0.00 % OA 18.0 18.0 Duct Heat Pkup 0 0 0: System Plenum Heat 540 -2.76 cfm/ft' 0.96 0.96 Underflr Sup Ht Pkup 0 0: Underfir Sup Ht Pkup 0 0.00 cfm/ton 284.36 Supply Air Leakage 0 0 0: ; Supply Air Leakage 0 0.00 fV/ton 296.31 Btu/heft' 40.50 -9.82 Grand Total ==> 44,219 3,495 49,194 100.00' 40,550 100.00 ' Grand Total ==> -9,609 -19,595 100.00 No. People 21 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR ton MBh MBh cfm °F °F gr/Ib °F °F gr/lb Main Clg 4.1 49.2 43.3 1,915 72.2 59.9 57.4 53.8 50.7 49.9 Aux Cig 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 2.6 31.6 14.7 345 92.3 79.2 130.2 54.0 53.9 62.0 Total 6.7 80.8 AREAS Gross Total Glass ft' (%) Floor 1,995 Part 0 Int Door 0 ExFIr 0 Roof 1,995 0 0 Wall 2,850 503 18 Ext Door 145 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F i Htg -10.7 1,915 67.5 72.5 Htg 0.0 0 0.0 0.0 seat 0.0 0 0.0 0.0 ddif 0.0 0 0.0 0.0 Vent -8.9 345 45.0 68.0 1/ -19.6 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Altemative - 1 System Checksums Report Page 6 of 15 Zone Checksums By RGD Zone - 007A COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK Peaked at Time: Mo/Hr: 7 / 19 Mo/Hr: 6 / 19 Mo/Hr: Heating Design OutsideAir: OADBANB/HR: 87 / 76 / 120 OADB: 85 OADB: 45 Space Plenum Net Percent: Space Percent Space Peak Coil Peak Percent Sens. + Lat. Sens. + Lat Total Of Total ; Sensible Of Total Space Sens Tot Sens Of Total Btu/h Btu/h Btu/h (%): Btu/h (%) Btu/h Btu/h (%) Envelope Loads ; Envelope Loads Skylite Solar 0 0 0 0: 0 0 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0: 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 374 374 7. 0 0 Roof Cond 0 -155 10.26 Glass Solar 1,353 0 1,353 26. 1,392 34 ; Glass Solar 0 0 0.00 GlasslDoor Cond 342 0 342 7 : 314 8 : Glass/Door Cond -463 -463 30.67 Wall Cond 293 128 420 8 288 7: Wall Cond -175 -255 16.89 Partition/Door 0 0 0 0 0: Partition/Door 0 0 0.00 Floor 0 0 0: 0 0 Floor 0 0 0.00 Adjacent Floor 0 0 0 0; 0 0: Adjacent Floor 0 0 0.00 Infiltration 0 0 0; 0 0: Infiltration 0 0 0.00 Sub Total ==> 1,989 502 2,490 49 1,993 49 Sub Total ==> -638 -873 57.82 Internal Loads Internal Loads ; Lights 879 0 879 17 : 879 22 Lights 879--879 -58.17 People 1,100 0 1,100 22: 550 14 ' People 550 550 -36.42 Misc 399 0 399�8: 399 10: Misc 399 399 -26.44 Sub Total ==> _2,378 0 2,378 47 ; 1,828 45 ; Sub Total==> 1,828 1,828 -121.03 Ceiling Load 219 -219 0 0: 216 5 : Ceiling Load -48 0 0.00 Ventilation Load 0 0 377 7: 0 0: Ventilation Load 0 0 0.00 Adj Air Trans Heat 0 0 0: 0 0 ; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0: :Ov/UndrSizing 0 0 0.00 Ov/Undr Sizing 0 0 0: 0 0 Exhaust Heat 39 -2.59 Exhaust Heat -178 -178 -3: OA Preheat Diff. -1,386 91.74 Sup. Fan Heat 44 1 • RA Preheat Diff. -1,142 75.60 Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 : ; System Plenum Heat 23 -1.55 Underfir Sup Ht Pkup 0 0. Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0: ; Supply Air Leakage 0 0.00 Grand Total =_> 4,586 104 5,111 100.00' 4,037 100.00 ' Grand Total ==> 1,142 -1,510 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/lb Main Clg 0.4 5.1 4.4 226 73.0 60.3 58.1 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.4 5.0 2.3 54 92.3 79.2 130.2 Total 0.8 10.1 Leave DI `F -F 53.8 52.4 0.0 0.0 54.0 53.9 gr/lb 56.2 0.0 62.0 AREAS Gross Total Glass ftz (%) Floor 234 Part 0 Int Door 0 ExFlr 0 Roof 234 0 0 Wall 237 40 17 Ext Door Q� 0 0 TEMPERATURES Cooling Heating SADB 54.0 68.0 Ra Plenum 73.0 67.4 Return 73.0 67.4 ReVOA 73.0 67.5 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.1 0.0 AIRFLOWS Cooling Heating Diffuser 226 226 Terminal 226 226 Main Fan 226 226 Sec Fan 0 0 Nom Vent 54 54 AHU Vent _54�54 -Infil 0 0 MinStop/Rh 0 0 Return 226 226 Exhaust 54 54 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % OA 23.9 23.9 cfm/ft, 0.97 0.97 cfm/ton 270.08 WIton 279.19 Btu/heft' 42.98 -6.45 No. People 2 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F i Htg -0.1 226 67.5 68.0 Htg 0.0 0 0.0 0.0 seat 0.0 0 0.0 0.0 iidif 0.0 0 0.0 0.0 Vent -1.4 54 45.0 68.0 i/ -1.5 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative -1 System Checksums Report Page 7 of 15 Zone Checksums By RGD Zone-007B COOLING COIL PEAK Peaked at Time: Mo/Hr: 7115 Outside Air: OADBMIB/HR: 91 / 78 / 124 Space Plenum Net Percent: Sens. + Lat. Sens. + Lat Total Of Total ; Btu/h Btu/h Btu/h (%): Envelope Loads Skylite Solar 0 0 0 0: Skylite Cond 0 0 0 0: Roof Cond 0 666 666 22 ; CLG SPACE PEAK Mo/Hr: 7 / 15 OADB: 91 Space Percent: Sensible Of Total Btu/h (%) : : Envelope Loads 0 0 : Skylite Solar 0 0: Skylite Cond 0 0 Roof Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 45 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 0 -158 Percent Of Total (%) 0.00 0.00 10.99 TEMPERATURES Cooling SADB 54.0 Re Plenum 73.8 Return 73.8 Ret/OA 73.4 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 68.0 67.4 67.4 67.7 0.0 0.0 0.0 Glass Solar 0 0 0 0; 0 0 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0: 0 0 Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 0 0 0 0 : 0 0. Wall Cond 0 0 0.00 Partition/Door 0 0 0: 0 0: Partition/Door 0 0 0.00 Diffuser 120 120 Floor 0 0 0: 0 0: Floor 0 0 0.00 Terminal 120 120 Adjacent Floor 0 0 0 0. 0 0 ; Adjacent Floor 0 0 0.00 Main Fan 120 120 Infiltration 0 0 0 0 0: Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total ==> 0 666 666 22 : 0 0 : Sub Total ==> 0 -158 10.99 Nom Vent 54 54 AHU Vent 54 54- Internal Loads ; Internal Loads lnfil 0 0 Lights 897 0 897 29 ; 897 42 ' Light 897 897 -62.28 MinStop/Rh 0 0 People 1,100 0 1,100 36� --55 20 6 People 550 550 -38.18 Return 120 120 Misc 0- 408 13: 408 19: Misc 408 408 -28.31 Exhaust 54 54 _____408-- -Sub Total ==> 2,405 0 2,405 78 : 1,855 87 ; Sub Total ==> 1,855 1,855 -128.77 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 284 -284 0 0: 284 13 : Ceiling Load -49 0 0.00 Leakage own 0 0 Ventilation Load 0 0 224 7: 0 0: Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 ; 0 0 ; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0: : Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0: 0 0 Exhaust Heat 39 -2.73 ENGINEERING CKS Exhaust Heat -227 -227 -7: OA Preheat Diff. -1,393 96.71 Sup. Fan Heat 23 1 • RA Preheat Diff. -1,806 125.36 Cooling Heating Ret. Fan Heat 0 0 0: ; Additional Reheat 0 0.00 % OA 45.3 45.3 Duct Heat Pkup 0 0 0: ; System Plenum Heat 22 -1.55 cfm/ft' 0.50 0.50 Underflr Sup Ht Pkup 0 0: : Underflr Sup Ht Pkup 0 0.00 cfm/ton 178.43 Supply Air Leakage 0 0 0: Supply Air Leakage 0 0.00 ft'/ton 355.60 Btu/hr-ft' 33.75 -6.03 Grand Total==> 2,689 155 3,091 100.00' 2,139 100.00 " Grand Total ==> 1,806 -1,441 100.00 No. People 2 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/lb Main Clg 0.3 3.1 2.5 120 73.4 61.2 61.4 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.4 5.0 2.3 54 92.3 79.2 130.2 Total 0.7 8.1 Leave DB/WB/HR °F °F gr/lb 53.8 52.2 55.8 0.0 0.0 0.0 54.0 53.9 62.0 AREAS Gross Total Glass ft2 (%) Floor 239 Part 0 Int Door 0 ExFlr 0 Roof 239 0 0 Wall 0 0 0 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F i Htg -0.1 120 67.7 68.0 Htg 0.0 0 0.0 0.0 seat 0.0 0 0.0 0.0 iidif 0.0 0 0.0 0.0 Vent -1.4 54 45.0 68.0 r/ -1.4 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative -1 System Checksums Report Page 8 of 15 Zone Checksums By RGD Zone - 009 COOLING COIL PEAK Peaked at Time: Mo/Hr: 6 / 19 Outside Air: OADB/ B/HR: 85 / 74 / 110 Space Plenum Net Percent: Sens. + Lat. Sens. + Lat Total Of Total ; Btu/h Btu/h Btu/h (%) : Envelope Loads Skylite Solar 0 0 0 0: Skylite Cond 0 0 0 0: Roof Cond 0 1,176 1,176 7; CLG SPACE PEAK Mo/Hr: 6 / 19 OADB: 85 Space Percent: Sensible Of Total ; Btu/h (%) : : Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0; Roof Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 45 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 0 -498 Percent Of Total (%) 0.00 0.00 10.65 TEMPERATURES Cooling SADB 54.0 Ra Plenum 72.9 Return 72.9 Ret/OA 72.9 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 68.0 67.4 67.4 67.5 0.0 0.0 0.0 Glass Solar 6,338 0 6,338 37 : 6,338 46 : Glass Solar 0 0 0.00 AIRFLOWS Glass/DoorCond 784 0 784 5: 784 6: Glass/DoorCond -1,158 -1,158 24.76 Cooling Heating Wall Cond 305 175 480 3 : 305 2 : Wall Cond -186 -297 6.36 Partition/Door 0 0 0: 0 0: Partition/Door 0 0 0.00 Diffuser 778 778 Floor 0 0 0: 0 0 Floor 0 0 0.00 Terminal 778 778 Adjacent Floor 0 0 0 01 0 0 Adjacent Floor 0 0 0.00 Main Fan 778 778 Infiltration 0 0 0: 0 0: Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 7,428 1,351 8,779 52 : 7,428 54 ; Sub Total ==> -1,343 -1,953 41.76 Nom Vent 165 165 AHU Vent 165-165 Internal Loads Internal Loads TfiI 0 0 Lights 2,823 0 2,823 17 ; 2,823 201 Lights 2,823 2,823 -60.36 MinStop/Rh 0 0 People 3,300 0 3,300 19: 1,650 f2: People 1,650 1,650 -35.28 Return 778 778 Misc 1,283�0-1,283 8: 1,283 9: Misc 1,283 1,283 -27.44 Exhaust 165 165 _ _Sub -Total =_> 7,407 0 7,407 43. 5,757 41 Sub Total ==> 5,757 5,757 -123.08 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 695 -695 0 0 : 695 5 : Ceiling Load -155 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 1,241 7. 0 0: Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 ; 0 0 ; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0: :Ov/UndrSizing 0 0 0.00 Ov/Undr Sizing 0 0 0: 0 0 Exhaust Heat 119 -2.55 ENGINEERING CKS Exhaust Heat -537 -537 -3: OA Preheat Diff. -4,233 90.52 Sup. Fan Heat 150 1 • RA Preheat Diff. -4,259 91.05 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 21.2 21.2 Duct Heat Pkup 0 0 0: ; System Plenum Heat -108 2.31 cfm/ft' 1.03 1.03 UnderfIr Sup Ht Pkup 0 0: Underflr Sup Ht Pkup 0 0.00 cfm/ton 290.43 Supply Air Leakage 0 0 0: ; Supply Air Leakage 0 0.00 ft'/ton 280.65 Btu/heft' 42.76 -6.22 Grand Total ==> 15,530 118 17,039 100.00' 13,880 100.00 ' Grand Total ==> 4,258 -4,677 100.00 No. People 6 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/lb Main Clg 1.4 17.0 14.7 778 72.9 60.1 57.4 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 1.3 15.1 7.1 165 92.3 79.2 130.2 Total 2.7 32.2 Leave DB/WB/HR °F °F gr/Ib 53.8 52.4 56.4 0.0 0.0 0.0 54.0 53.9 62.0 AREAS Gross Total Glass Floor 752 Part 0 Int Door 0 ExFlr 0 Roof 752 0 0 Wall 330 100 30 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F i Htg -0.4 778 67.5 68.0 Htg 0.0 0 0.0 0.0 seat 0.0 0 0.0 0.0 iidif 0.0 0 0.0 0.0 Vent -4.2 165 45.0 68.0', 1t -4.7 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11102/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative -1 System Checksums Report Page 9 of 15 Zone Checksums By RGD Zone - 010a COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES Peaked at Time: Mo/Hr: 7115 Mo/Hr: 7/15 Mo/Hr: Heating Design Cooling Heating Outside Air: OADBI B/HR: 91 / 78 / 124 OADB: 91 OADB: 45 SADB 54.0 68.0 Ra Plenum 73.8 67.4 Space Plenum Net Percent: Space Percent: Space Peak Coil Peak Percent Return 73.8 67.4 Sens. + Lat. Sens. + Lat Total Of Total : Sensible Of Total ; Space Sens Tot Sens Of Total Ret/OA 73.5 67.5 Btu/h Btu/h Btulh (%): Btu/h (%) : Btu/h Btu/h (%) Fn MtrTD 0.0 0.0 Envelope Loads : Envelope Loads Fn BIdTD 0.0 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 0.1 0.0 Skylite Cond 0 0 0 0: 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 496 496 21 • 0 0 Roof Cond 0 -118 20.80 Glass Solar 0 0 0 0: 0 0; Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 0 0 0 0 0 0. Wall Cond 0 0 0.00 Partition/Door 0 0 0 0 0: Partition/Door 0 0 0.00 Diffuser 71 71 Floor 0 0 0: 0 0 Floor 0 0 0.00 Terminal 71 71 Adjacent Floor 0 0 0 0 ; 0 0 Adjacent Floor 0 0 0.00 Main Fan 71 71 Infiltration 0 0 0: 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total ==> 0 496 496 21: 0 0 Sub Total ==> 0 -118 20.80 Nom Vent 21 21 AHU Vent 21 21 Internal Loads ; Internal Loads Infil 0 0 Lights 668 0 668 28 ; 668 44=L-ight 668 668 -117.87 MinStop/Rh 0 0 People 900 0 900 38 500 33: People 500 500 -88.19 Return 71 71 Misc _ --304--'0 304 13 : 304 20 : Misc 304 304 -53.58 Exhaust 21 21 f� _ Sub Total =_> 1,872 0 1,872 79 : 1,472 97 : Sub Total ==> 1,472 1,472 -259.64 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 42 -42 0 0: 42 3 : Ceiling Load -37 0 0.00 Leakage Own 0 0 Ventilation Load 0 0 -8 0: 0 0: Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 : 0 0 ; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0: : Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0: 0 0 Exhaust Heat 15 -2.64 ENGINEERING CKS Exhaust Heat -17 -17 -1 OA Preheat Diff. -530 93.52 Sup. Fan Heat 14 1 • RA Preheat Diff. -1,435 253.18 Cooling Heating Ret. Fan Heat 0 0 0: ; Additional Reheat 0 0.00 % OA 28.9 28.9 Duct Heat Pkup 0 0 0: ; System Plenum Heat 30 -5.22 cfm/ft' 0.40 0.40 Undertlr Sup Ht Pkup 0 0: Underflr Sup Ht Pkup 0 0.00 cfm/ton 201.86 Supply Air Leakage 0 0 0: ; Supply Air Leakage 0 0.00 ft'/ton 502.58 Btu/heft' 23.88 -3.19 Grand Total ==> 1,914 437 2,357 100.00 ' 1,514 100.00 ' Grand Total ==> 1,435 -567 100.00 No. People 2 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBfVVB/HR ton MBh MBh cfm °F °F gr/lb Main Clg 0.2 2.4 2.0 71 73.5 61.5 62.4 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.2 1.9 0.9 21 92.3 79.2 130.2 Total 0.4 4.3 Leave DB/WB/HR °F °F gr/lb 53.8 49.8 46.8 0.0 0.0 0.0 54.0 53.9 62.0 AREAS Gross Total Glass ft' (%) Floor 178 Part 0 Int Door 0 ExFlr 0 Roof 178 0 0 Wall 0 0 0 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F i Htg 0.0 71 67.5 Htg 0.0 0 0.0 seat 0.0 0 0.0 ddif 0.0 0 0.0 Vent -0.5 21 45.0 1 -0.6 0.0 0.0 0.0 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Altemative -1 System Checksums Report Page 10 of 15 Zone - 010b COOLING COIL PEAK Peaked at Time: Mo/Hr: 8 / 16 Outside Air: OADBM/B/HR: 92 / 79 / 130 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total : Btu/h Btu/h Btu/h (%): Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 531 531 14 Glass Solar 0 0 0 0 ; Glass/Door Cond 0 0 0 0 Wall Cond 504 180 685 19 : Partition/Door 0 0 0 Floor 0 0 0 Adjacent Floor 0 0 0 0. Infiltration 0 0 0. Sub Total ==> 504 712 1,216 33 Internal Loads Zone Checksums By RGD CLG SPACE PEAK Mo/Hr: 9 / 16 ; OADB: 90 Space Percent Sensible Of Total ; Btu/h (%) : Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 Roof Cond 0 0 ; Glass Solar 0 0 : Glass/Door Cond 520 22. Wall Cond 0 0 Partition/Door 0 0 Floor 0 0 ; Adjacent Floor 0 0: Infiltration 520 22 Sub Total =_> Internal Loads HEATING COIL PEAK Mo/Hr: Heating Design OADB: 45 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu/h (%) 0 0 0.00 0 0 0.00 0 -133 17.61 0 0 0.00 ,. 0 0 0.00 -291 -394 52.08 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 -291 -527 69.69 Lights 755 0 755 21 ; 755 31 ' Lights 755 755 -99.79 People 1,350 0 1,350 37��750 31 : People 750 750 -99.18 Misc - __343-0- 343 9 : 343 14 : Misc 343 343 -45.36 - --- --Sud Total �> 2,448 0 2,448 67. 1,848 77 ; Sub Total==> 1,848 1,848 -244.33 Ceiling Load 44 -44 0 0 32 1 : Ceiling Load -41 0 0.00 Ventilation Load 0 0 0 0. 0 0 Ventilation Load 0 0 0.00 Adj Air Trans Heat 0 0 0 0 0; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 : Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0. 0 0 Exhaust Heat 20 -2.59 Exhaust Heat -21 -21 -1 OA Preheat Diff. -694 91.75 Sup. Fan Heat 22 1 RA Preheat Diff. -1,515 200.38 Ret. Fan Heat 0 0 0 ; ; Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 ; ; System Plenum Heat 113 -14.90 Underflr Sup Ht Pkup 0 0 Underfir Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0 ; Supply Air Leakage 0 0.00 Grand Total ==> 2,996 647 3,665 100.00 2,400 100.00 Grand Total ==> 1,515 -756 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBNVBIHR ton MBh MBh cfm °F °F grfib Main Clg 0.3 3.7 3.1 113 73.5 61.4 62.0 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.2 2.5 1.2 27 92.3 79.2 130.2 Total 0.5 6.1 Leave DB/WB/HR, °F °F gr/Ib 53.8 49.9 47.3 0.0 0.0 0.0 54.0 53.9 62.0 AREAS Gross Total Glass ftz (%) Floor 201 Part 0 Int Door 0 ExFlr 0 Roof 201 0 0 wall 304 0 0 Ext Door 0 0 0 TEMPERATURES Cooling Heating SADB 54.0 68.0 Ra Plenum 73.7 67.4 Return 73.7 67.4 Ret/OA 73.5 67.5 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.1 0.0 AIRFLOWS Cooling Heating Diffuser 113 113 Terminal 113 113 Main Fan 113 113 Sec Fan 0 0 Nom Vent 27 27 AHU Vent 27 27 1 fil 0 0 MinStop/Rh 0 0 Return 113 113 Exhaust 27 27 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % OA 23.9 23.9 cfm/ft' 0.56 0.56 cfm/ton 221.39 ft'/ton 392.72 Btu/heft' 30.56 -3.76 No. People 3 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F i Htg -0.1 113 67.5 68.0 Htg 0.0 0 0.0 0.0 seat 0.0 0 0.0 0.0 fidif 0.0 0 0.0 0.0 Vent -0.7 27 45.0 68.0 d -0.8 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative-1 System Checksums Report Page 11 of 15 Zone Checksums By RGD Zone - 010c COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK Peaked at Time: Mo/Hr: 7 117 Mohr: 7 / 17 Mo/Hr: Heating Design Outside Air: OADBMIB/HR: 90 / 77 / 123 OADB: 90 OADB: 45 Space Plenum Net Percent: Space Percent: Space Peak Coil Peak Percent Sens. + Lat. Sens. + Lat Total Of Total ; Sensible Of Total Space Sens Tot Sens Of Total Btu/h Btu/h Btu/h (%): Btu/h (%) Btu/h Btu/h (%) Envelope Loads ; Envelope Loads Skylite Solar 0 0 0 0: 0 0 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0: 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 396 396 13 • 0 0 Roof Cond 0 -107 19.12 Glass Solar 0 0 0 0: 0 0 Glass Solar 0 0 0.00 Glass/Door Cond 0 0 0 0: 0 0 Glass/Door Cond 0 0 0.00 Wall Cond 586 209 795 26 : 586 29 : Wall Cond -410 -554 99.35 Partition/Door 0 0 0: 0 0 Partition/Door 0 0 0.00 Floor 0 0 0 0 0 Floor 0 0 0.00 Adjacent Floor 0 0 0 0; 0 0; Adjacent Floor 0 0 0.00 Infiltration 0 0 0: 0 0: Infiltration 0 0 0.00 Sub Total ==> 586 606 1,191 40 : 586 29 ; Sub Total ==> -410 -661 118.47 Internal Loads ; Internal Loads Lights 604 0 604 20: 604 30 ; Lights 604 604 -108.34 People 900 0 900 30 : 500 25-P6-o-p a 500 500 -89.62 Misc 275 0 27.5-9: 275 14: Misc 275 275 -49.24 Sub Total ==> _ 1-779- 0 1,779 59 : 1,379 69 Sub Total ==> 1,379 1,379. -247.20 Ceiling Load 28 -28 0 0. 28 1 Ceiling Load -33 0 0.00 Ventilation Load 0 0 26 1: 0 0 Ventilation Load 0 0 0.00 Adj Air Trans Heat 0 0 0; 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0. Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0: 0 0 Exhaust Heat 14 -2.55 Exhaust Heat -12 -12 0: OA Preheat Diff. -504 90.34 Sup. Fan Heat 18 1 • RA Preheat Diff. -937 167.85 Ret. Fan Heat 0 0 0 : ; Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 ; ; System Plenum Heat 150 -26.92 Underflr Sup Ht Pkup 0 0 : : Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0. Supply Air Leakage 0 0.00 Grand Total ==> 2,393 565 3,003 100.00 ' 1,993 100.00 Grand Total ==> 937 -558 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/lb Main Clg 0.3 3.0 2.6 94 73.4 61.0 60.5 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.2 1.8 0.8 20 92.3 79.2 130.2 Total 0.4 4.8 Leave DBIWB/HR °F °F gr1lb 53.8 49.6 46.2 0.0 0.0 0.0 54.0 53.9 62.0 AREAS Gross Total Glass ft2 (%) Floor 161 Part 0 Int Door 0 ExFlr 0 Roof 161 0 0 Wall 428 0 0 Ext Door 0 0 0 TEMPERATURES Cooling Heating SADB 54.0 68.0 Ra Plenum 73.6 67.4 Return 73.6 67.4 Ret/OA 73.4 67.5 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.1 0.0 Cooling Heating Diffuser 94 94 Terminal 94 94 Main Fan 94 94 Sec Fan 0 0 Nom Vent 20 20 AHU Vent 20�20 -Infil 0 0 MinStop/Rh 0 0 Return 94 94 Exhaust 20 20 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % OA 20.9 20.9 cfm/ft' 0.58 0.58 cfmlton 235.13 ft'/ton 402.30 Btu/heft' 29.83 -3.47 No. People 2 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -0.1 94 67.5 68.0 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent -0.5 20 45.0 68.0 Total -0.6 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11102/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative -1 System Checksums Report Page 12 of 15 Zone Checksums By RGD Zone - 010d COOLING COIL PEAK Peaked at Time: Mo/Hr: 7 / 15 Outside Air: OADB/WB/HR: 91 / 78 / 124 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h (%): Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0: Roof Cond 0 446 446 20 CLG SPACE PEAK Mo/Hr: 7 / 15 OADB: 91 Space Percent: Sensible Of Total ; Btu/h (%) : : Envelope Loads 0 0 : Skylite Solar 0 0 Skylite Cond 0 0: Roof Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 45 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 0 -106 Percent Of Total (%) 0.00 0.00 19.75 TEMPERATURES Cooling SADB 54.0 Ra Plenum 73.8 Return 73.8 Ret/OA 73.5 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 68.0 67.4 67.4 67.5 0.0 0.0 0.0 Glass Solar 0 0 0 0 0 0; Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0 0 0: Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 0 0 0 0: 0 0. Wall Cond 0 0 0.00 Partition/Door 0 0 0. 0 0 Partition/Door 0 0 0.00 Diffuser 67 67 Floor 0 0 0: 0 0 Floor 0 0 0.00 Terminal 67 67 Adjacent Floor 0 0 0 0 ; 0 0 ; Adjacent Floor 0 0 0.00 Main Fan 67 67 Infiltration 0 0 0: 0 0: Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 0 446 446 20 : 0 0 Sub Total ==> 0 -106 19.75 Nom Vent 20 20 AMU Vent 20-2o Internal Loads Internal Loads Infil 0 0 Lights 601 0 601 27 ; 601 43 Lights 601 601 -111.96 MinStop/Rh 0 0 People 900 0 900 41 : 500 35 People 500 500 -93.19 Return 67 67 Misc 273 0 _ 273 1 273 19 : Misc 273 273 -50.89 Exhaust 20 20 Sub Total _>------1;774 _ 0 1,774 81 ; 1,374 97 ; Sub Total =_> 1,374 1,374 -256.04 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 38 -38 0 0: 38 3 : Ceiling Load -33 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 -17 -1 : 0 0 : Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0. 0 0 ; Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0: : Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0. 0 0 Exhaust Heat 14 -2.64 ENGINEERING CKS Exhaust Heat -16 -16 -1 OA Preheat Diff. -503 93.66 Sup. Fan Heat 13 1: RA Preheat Diff. -1,341 249.90 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 29.4 29.4 Duct Heat Pkup 0 0 0 ; System Plenum Heat 25 -4.63 cfm/ft' 0.42 0.42 Underflr Sup Ht Pkup 0 0: Underflr Sup Ht Pkup 0 0.00 cfm/ton 200.29 Supply Air Leakage 0 0 0: ; Supply Air Leakage 0 0.00 ft'lton 480.81 Btu/heft' 24.96 -3.35 Grand Total==> 1,812 392 2,199 100.00 1,412 100.00 ' Grand Total =_> 1,341 -537 100.00 No. People 2 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR ton MBh MBh cfm °F °F grAb °F °F gr/lb Main Clg 0.2 2.2 1.8 67 73.5 61.6 62.9 53.8 49.9 47.3 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.2 1.8 0.8 20 92.3 79.2 130.2 54.0 53.9 62.0 Total 0.3 4.0 AREAS Gross Total Glass ft' (%) Floor 160 Part 0 Int Door 0 ExFlr 0 Roof 160 0 0 Wall 0 0 0 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg 0.0 67 67.5 68.0 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent -0.5 20 45.0 68.0 Total -0.5 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative -1 System Checksums Report Page 13 of 15 Zone Checksums By RGD Zone - 011 COOLING COIL PEAK Peaked at Time: Mo/Hr: 6 / 18 Outside Air: OADBMIB/HR: 87 / 76 / 116 Space Plenum Net Percent: Sens. + Lat. Sens. + Lat Total Of Total ; Bluth Btu/h Btu/h (%): Envelope Loads Skylite Solar 0 0 0 0: Skylite Cond 0 0 0 0: Roof Cond 0 2,578 2,578 7 ; CLG SPACE PEAK Mo/Hr: 6118 OADB: 87 Space Percent Sensible Of Total ; Btu/h (%) : : Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 ; Roof Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 45 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 0 -790 Percent Of Total (%) 0.00 0.00 4.88 TEMPERATURES Cooling SADB 54.0 Ra Plenum 73.3 Return 73.3 Ret/OA 73.2 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 68.0 67.4 67.4 67.6 0.0 0.0 0.0 Glass Solar 13,400 0 13,400 35 ; 13.400 46 : Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 1,354 0 1,354 4 : 1,344 5 : Glass/Door Cond -2,172 -2,172 13.43 Cooling Heating Wall Cond 1,061 518 1,580 4 : 1,079 4. Wall Cond -797 -1,178 7.28 Partition/Door 0 0 0. 0 0 Partition/Door 0 0 0.00 Diffuser 1,363 1,363 Floor 0 0 0: 0 0 Floor 0 0 0.00 Terminal 1,363 1,363 Adjacent Floor 0 0 0 0 ; 0 0 ; Adjacent Floor 0 0 0.00 Main Fan 1,363 1,363 Infiltration 0 0 0: 0 0: Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 15,815 3,096 18,911 50, 15,823 55 : Sub Total ==> -2,970 -4,141 25.60 Nom Vent 610 610 AHU Vent 610-610 Internal Loads Internal Loads -Infil 0 0 Lights 4,525 0 4,525 12 ; 4,525 16 Lights -525 4,525 27.97 MinStop/Rh 0 0 People 11,054 0 11,054 29: 6,141 21 : People 6,141 6,141 -37.96 Return 1,363 1,363 Misc 2,271 0 2,271 6: 2,27--1 8 MMisc 2,271 2,271 -14.04 Exhaust 610 610 Sub Total ==> 17,851 0_ 1-7;8514 12,938 45: Sub Total ==> 12,938 12,938 -79.97 Rm Exh 0 0 Auxiliary 0 0 Ceiling -Load _ - 121 -121 0 0: 115 0 : Ceiling Load -245 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 1,213 3: 0 0 Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 ; 0 0 ; Adj Air Trans Heat 0 0 0 Dehu`mid. Ov Sizing 0 0: Ov/Undr Sizing 0 0 0.00 Ov/Undr sizing 0 0 0: 0 0 Exhaust Heat 441 -2.73 ENGINEERING CKS Exhaust Heat -184 -184 0: OA Preheat Diff. -15,633 96.63 Sup. Fan Heat 263 1 : RA Preheat Diff. -9,722 60.10 Cooling Heating Ret. Fan Heat 0 0 0: ; Additional Reheat 0 0.00 % OA 44.7 44.7 Duct Heat Pkup 0 0 0: ; System Plenum Heat -61 0.37 cfm/ft' 1.14 1.14 Underflr Sup Ht Pkup 0 0: Underflr Sup Ht Pkup 0 0.00 cfm/ton 174.28 Supply Air Leakage 0 0 0: ; Supply Air Leakage 0 0.00 Wilton 152.51 Btu/heft' 78.68 -13.56 Grand Total ==> 33,787 2,791 38,054 100.00 28,875 100.00 Grand Total ==> 9,722 -16,178 100.00 No. People 25 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/Ib Main Clg 3.2 38.1 31.9 1,363 73.2 60.9 60.5 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 4.7 55.8 26.0 610 92.3 79.2 130.2 Total 7.8 93.9 Leave DB/WB/HR °F °F gr/lb 53.8 51.1 51.4 0.0 0.0 0.0 54.0 53.9 62.0 AREAS Gross Total Glass ft2 (%) Floor 1,193 Part 0 Int Door 0 ExFlr 0 Roof 1,193 0 0 Wall 1,080 170 16 Ext Door 45 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F i Htg -0.6 1,363 67.6 68.0 Htg 0.0 0 0.0 0.0 seat 0.0 0 0.0 0.0 iidif 0.0 0 0.0 0.0 Vent -15.6 610 45.0 68.0 U -16.2 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative -1 System Checksums Report Page 14 of 15 Zone - 012 COOLING COIL PEAK Peaked at Time: Mo/Hr: 6 / 9 Outside Air: OADBMIB/HR: 80 / 71 / 99 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total ; Btu/h Btu/h Btu/h (%): Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 397 397 3 Glass Solar 7,904 0 7,904 53 ; Glass/Door Cond 502 0 502 3. Wall Cond 406 209 614 4 Partition/Door 0 0 0 Floor 0 0 0 Adjacent Floor 0 0 0 0 ; Infiltration 0 0 0 Sub Total =_> 8,811 606 9,417 64 Internal Loads Lights 2,093 -People 1,600 Misc 1,203 Sub Total =_> 4,896 Ceiling Load -134 Ventilation Load 0 Adj Air Trans Heat 0 Dehumid. Ov Sizing Ov/Undr Sizing 0 Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total ==> 13,573 -0 7093 14 ; 0 1,600 11 0 1,203 8 0 4,896 33: 134 0 0: 0 340 2 0 0; 0 0 0 0 49 49 0 118 1 0 0 0; 0 0 0: 0 0: 0 0 0 789 14,820 100.00 Zone Checksums By RGD CLG SPACE PEAK Mo/Hr: 6 / 9 OADB: 80 Space Percent: Sensible Of Total Btu/h (%) ; Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 Roof Cond 7,904 61 Glass Solar 511 4 : Glass/Door Cond 400 3 : Wall Cond 0 0 Partition/Door 0 0 Floor 0 0 Adjacent Floor 0 0 Infiltration 8,815 68 Sub Total ==> 2,093 16 Lights 980 8 People 1,203 9 Misc 4,276 33 Sub Total ==> -134 -1 : Ceiling Load 0 0 Ventilation Load 0 0 ; Adj Air Trans Heat Ov/Undr Sizing 0 0 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underfir Sup Ht Pkup Supply Air Leakage 12,957 100.00 ' Grand Total =_> COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBIWB/HR ton MBh MBh cfm °F °F gr/lb Main Cig 1.2 14.8 13.9 612 72.3 59.0 53.5 Aux Cig 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.4 4.8 2.2 52 92.3 79.2 130.2 Total 1.6 19.6 Leave DBIWB/HR °F °F gr/lb 53.8 50.2 48.2 0.0 0.0 0.0 54.0 53.9 62.0 HEATING COIL PEAK Mo/Hr: Heating Design OADB: 45 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu/h (%) 0 0 0.00 0 0 0.00 0 -356 20.40 0 0 0.00 -1,643 -1,643 94.24 -502 -758 43.44 TEMPERATURES Cooling Heating SADB 54.0 68.0 Ra Plenum 72.2 67.4 Return 72.2 67.4 Ret/OA 72.3 67.4 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.1 0.0 AIRFLOWS Cooling Heating 0 0 0.00 Diffuser 612 612 0 0 0.00 Terminal 612 612 0 0 0.00 Main Fan 612 612 0 0 0.00 Sec Fan 0 0 -2,145 -2,757 158.09 Nom Vent 52 52 2,093 980 1,203 4,276 -110 0 0 0 2,020 - -AHU Vent-52 52 Infil 0 0 2,093 -120.01 MinStop/Rh 0 0 980 -56.20 Return 612 612 1,203 -69.00 Exhaust 52 52 4,276 -245.20 Rm Exh 0 0 Auxiliary 0 0 0 0.00 Leakage Dwn 0 0 0 0.00 Leakage Ups 0 0 0 0 0 0.00 38 -2.17 -1,339 76.78 -2, 020 115.83 0 0.00 58 -3.33 0 0.00 0 0.00 -1,744 100.00 AREAS Gross Total Glass ft2 (%) Floor 537 Part 0 Int Door 0 ExFlr 0 Roof 537 0 0 Wall 710 124 17 Ext Door 45 0 0 ENGINEERING CKS Cooling Heating 8.5 8.5 1.14 1.14 n 374.55 328.78 •ft2 36.50 -3.25 !ople 4 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F n Htg -0.4 612 67.4 68.0 Htg 0.0 0 0.0 0.0 heat 0.0 0 0.0 0.0 nidif 0.0 0 0.0 0.0 Vent -1.3 52 45.0 68.0 3/ -1.7 Project Name: 15-1039 TRACE® 700 v6.3.2 calculated at 10:04 AM on 11/02/2015 Dataset Name: HARBOUR RIDGE nrg.TRC Alternative -1 System Checksums Report Page 15 of 15