Loading...
HomeMy WebLinkAboutREVISION 11-26-18FILE COPY OFFICE UBL ONLY: DATE FILED: PERMIT # SnS ' O (0c7 REVISION FEE: RECEIPT# BY NED PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE StLucie COUBty FORT PIERCE, FL 34982.5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: (; DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME): OWNER/BUILDER INFORMATION: NAME: pL C f 3 0 N r� F b-,) CA e ADDRESS: c✓ CITY: S t_ STATE: PHONE (DAYTIME: 7.7 1 Li ct - oo t" Cn ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME): SLCCC. 9123109 Revised 06/30/17 w ST. LUCIE CO CERT. #: _ ZIP: FAX: f�I." ZIP: lj 'Alun0D ai:)nl -as }uawliedaa buipp-lad 810Z 9 9 AON ®3AI3:)32i STUCCO CEMENT FINISH V CMU WATER RESISTANT COATING FILLED CELL AT JAMB BLOCK (SEE WATER PROOFING NOTE # 1) (TYPICAL) CORROSION RESISTANT FLASHING ° - e. PER WATERPROOFING NOTE # 2 a a o: 1" X 3" P.T. WOOD FURRING ALL (3) SIDES CONTINUOUS. APPLY PERIMETER SEALANT CAULK O SEE WATER PROOFING NOTE # 6 BETWEEN BUCK & WINDOW FRAME (SEE WATERPROOFING NOTE # 5 ANCHOR 1 " X 4" P.T. (MIN.) BUCK WITH SEALANT' PER WATERPROOFING NOTE # 4, AND ANCHORED ; TO MASONRY WITH 1-1/2" CASE HARDENED COIL ` ,.7 NOTE: NAILS AT 12" O.C. MAX.A�7�o ra-Is t, d2" x�{" ►?T WIN W FRAME SHOULD BE COMPLETELY ANCHOR WINDOW FRAME TO MASONRY IN l ���� �t64 � 1'7 SEATED ON THE BUCK, IN NO INSTANCE SHALL -1, F & uJ nb C�2 QSaa�IMG 1ar�f� 8� STRICT ACCORDANCE WITH MANUFACTURE'S � THE FRAME OVERHANG THE BUCK PRODUCT APPROVAL INSTALLATION REQUIREMENTS. Xw &Nn "PZW b -To I1..k-614 WpLy -rttmV I K flo"414,;W 1•CW ' %hba vc �I�R:� Ad11J, IA " RRI0 15 wd.G WINDOW HEADER AND JAMBS TYPICAL BUCK DETAILNO SCALE I NOTE TAPCONS TO BE INSTALLED THRU BUCK INTO MASONRY w/MIN. 1-1/4" EMBEDMENT PER PRODUCTAPPROVAL PER FBC 1715.5.4.3 BUCKS MUST COVER ENTIRE DEPTH OF JAMBS. 1/8" -4-1/2� 3" -- 3/4 — NOTE: PRECAST CONCRETE WIND RESISTANT FLUSH w 3/8" SILL AS MANUFACTURED BY CAST-CRETE (OR EQUAL) C4o- 1-3/8 x° 7-5/8" PRECAST CONCRETE WINDOW SILL DE -TAIL NO SCALD - - - -- STUCCO CEMENT FINISH CMU WATER RESISTANT COATING (SEE WATER PROOFING NOTE # 1 ) APPLY PERIMETER SEALANT CAULK BETWEEN BUCK & WINDOW FRAME (SEE WATERPROOFING NOTE # 5) CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE # 2 SLIDING G NO SCALE FILLED CELL AT JAMB BLOCK (TYPICAL) 1" X 3" P.T. WOOD FURRING ALL (3) SIDES CONTINUOUS WOOD TRIM 1" X P. T. WOOD BUCK WITH SEALANT PER WATERPROOFING NOTE #4AND ANCHORED TO MASONRY WITH 1-1/2" CASE HARDENED COIL NAILS Q 12" O,C, MAX SEE WATER PROOFING NOTE # 6 ANCHOR DOOR JAMB AND HEADER TO 1 x BUCKS IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIREMENTS. R BUCK DETAIL STUCCO CEMENT FINISH CMU WATER RESISTANT COATING (SEE WATER PROOFING NOTE # 1 ) CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE # 2 APPLY PERIMETER SEALANT CAULK BETWEEN BUCK & WINDOW FRAME (SEE WATERPROOFING NOTE # 5) EXTERIOR DOOR BU NOTE: TAPCONS TO BE INSTALLED THRU BUCK INTO MASONRY w/ MIN. 1-1/4" EMBEDMENT PER PRODUCTAPPROVAL PER FBC 1715.5.4.3. BUCKS MUST COVER ENTIRE DEPTH OF JAMBS. NOTE: L /P6 - b 42f ST. LUCIE COUNTY BUILDING DIVISION REVIEW�FORMPLI CREVIEW DATE PLANS AND PERMIT MUS E KEPT ON JOB SITE OR NO INSPECTIO ) WILL BE MADE FILLED CELLAT JAMB BLOCK (TYPICAL) 1" X 3" P.T. WOOD FURRING ALL (3) SIDES CONTINUOUS WOOD TRIM 2" X P. T. WOOD BUCK WITH SEALANT PER WATERPROOFING NOTE # 4 AND ANCHORED TO MASONRY WITH 1/4" TAPCONS w/ MIN. 1-1/4" EMBED. 3" FROM EDGES & 12" O.C. MAX. SEE WATER PROOFING NOTE # 6 ANCHOR DOOR JAMB HEADER TO MASONRY IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIREMENTS. NOTE BUCK 2"X 6" P.T. RIPPED DOWN TO 2 X 4-1/8" P.T. W/ 3/16" TAPCONS 1-1/4"MIN. EMB. 4/12"O.C. w/# 10 SCREWS, PER PRODUCTAPPROVAL. WINDOWAND DOOR FENESTRATIONS SHALL BE IN ACCORDANCE WITH FMMA/AMA 200-9, CONTRACTOR SHALL SUBMIT FMMA /AMA 200-9 STANDARDS WITH PERMIT SUBMITTAL CONTINUOUS FOAM INTERIOR AIR AND WATER SEALANT PER WATERPROOFING NOTE # 6 MARBLE SILL MORTAR OR GROUT 1/2" DRYWALL FASTENERS.AS REQUIRED BY WINDOW MANUFACTURER CORROSION RESISTANT FLASHING PER WATERPROOFING (NOTE # 2) CAULK SEAM AT WINDOW INSTALLTION (SEE WATERPROOFING NOTE # 5) CMU WATER RESISTANT COATING (SEE WATER PROOFING NOTE # 1 ) SET SILL IN FULL MORTAR BED STUCCO OR DECORATIVE CEMENTITIOUS COATING 8" C.M.U. 3/4" FURRING TO MASONRY WALL WATERPROOFING NGTCS 1. PRIOR TO BUCK INSTALLATION TREAT THE MASONRY OPENING WITH A C IU WATER RESISTANT COATING TO SEAL THE WINDOW / DOOR CAVITY TO PREVENT IT FROM ABSORBING WAi ER. THE CMU WATER RESISTANT COATING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURE'S RECOMMENDATIONS. THE APPLICATION OF THE CMU WATER RESISTANT COATING SHALL INCLUDE THE ENTIRE SURROUND OF THE OPENING (SILLS, JAMBS, HEAD) AND RETURN WALLS OF THE OPENING 8" MINIMUM EACH DIRECTION. ALL CMU WATER RESISTANT COATINGS SHALL BE INSTALLED PRIOR TO BUCK INSTALLATIONS. 2. INSTALL BUCKS SO THAT THERE ARE NO EDGE GAPS EXCEEDING 1/8" BETWEEN BUCK AND MASONRY. 3. PRIOR TO BUCK INSTALLATION APPLY 3/8" NOMINAL DIAMETER BEAD OF SEALANT BETWEEN THE BUCK AND THE MASONRY TO PREVENT THE PASSAGE OF LIQUID BEHIND THE BUCK. COMPLETELY SEAL THE ENTIRE END OF THE WOOD BUCKS WITH SEALANT TO RESTRICT THE PASSAGE OF LIQUID THROUGH THE CUT ENDS AND THE ENTIRE EXTERIOR FACE AND RETURN SURFACE OF THE BUCK SHALL BE COATED WITH A LIQUID APPLIED WATER RESISTIVE COATING / SEALANT. 4. PROVIDE PAN FLASHING AT THE SILL OF WINDOW AND DOOR OPENINGS, PAN FLASHING SHALL BE SEALED OR SLOPED IN A MANNER TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WATER RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. INCORPORATE PAN FLASHING AT HEAD AND SILLAS WELL. PAN FLASHING SHALL BE CORROSION RESISTANT. (OPTIONAL, NOTREQUIRED) 5. PROVIDE CONTINUOUS 3/8" BEAD OF SEALANT ON WINDOW / DOOR FRANIES ATALL PERIMETER ON FRONT AND BACK SURFACE PRIOR TO WINDOW / DOOR INSTALLATION. 6. AFTER WINDOW / DOOR INSTALLATION PROVIDE FOAM SEALANT BETWEEN THE BUCK (OR PRECAST SILL) AND THE WINDOW / DOOR TO ENSURE A WATER RESISTANT INTERIOR AIRSEAL AROUND THE ENTIRE PERIMETER. SCANNED St Lucre CountV REVISION REVISION F- m U W W O. y U a W = O o ENGINEER PAUL WELCH INC. PAUL WELCH P.E. REG. # 29945 1984 S.W. BILTMORE ST. PORT ST. LUCIE,FL 34984 PHONE : (772) 785-9888 FAX: (772) 785-9933 U w 0 CN rn W It U O LU o U < Q 0 o LL LL � z m o U w Q L`n E W J J 0 � J LLJ n Ud CIO WCY) 0 W J L O C) 0. W 0 V LL � g J } U) W Z ry O ^ L..L T— O N SHEET DETAILS MODEL ARUBA DRAWN BILL SCHROEDER DATE JULY 03, 2018 SCALE AS NOTED. SHEET NO. 1® OF OF 10 SHEETS