Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFI E FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Basile Builder Name: Foglia Custom Homes Street: 6600 N. Hwy. A1A Permit Office: City, State, Zip: Fort Pierce , FL, 34949 Permit Number: Owner: Basile Jurisdiction: Design Location: FL, VERO_BEACH MUNICIPAL_AR IT County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From I lans) 9. Wall Types (12702.0 sqft.) Insulation Area 2. Single family or multiple family Single-fami y a. Concrete Block - Polystyrene Bead AggR=9.0 12382.00 ftZ b. Frame - Wood, Exterior R=19.0 320.00 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 3 d. N/A R= ftz 10. Ceiling Types (4669.9 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 4669.90 ft 6. Conditioned floor area above grade (ftZ) 8162.6591 968 b. N/A R= ftz c. R= ftZ Conditioned floor area below grade (ftZ) 0 11. Ducts R ftZ 7. Windows(4180.5 sqft.) Description Area 2 additional duct system(s) 6 408.13 a. U-Factor: Dbl, U=0.36 126U.80 ftZ b. Sup: System 2, Ret: System 2, AH: System 2 6 408.13 SHGC: SHGC=0.28 c. Sup: System 3, Ret: System 3, AH: System 3 (see detail _ b. U-Factor: Dbl, U=0.45 1212.70 ftZ 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit b. Central Unit 45.5 SEER:16.00 45.5 SEER:16.002 c. U-Factor: Dbl, U=0.63 8 3.21 ftZ additional cooling systems (see details) SHGC: SHGC=0.20 13. Heating systems kBtu/hr Efficiency d. V-Factor: other (see details) 8 3.78 ftZ a. Electric Heat Pump 45.5 HSPF:9.00 SHGC: other (see details) b. Electric Heat Pump 45.5 HSPF:9.00 Area Weighted Average Overhang Depth: P.489 ft. 2 additional heating systems (see details) Area Weighted Average SHGC: 0.218 14. Hot water systems a. Propane Tankless Cap: 1 gallons 8. Floor Types (4335.4 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 43 5.40 ftZ b. Conservation features b. NIA R= ftZ None c. N/A R= ftZ I 15. Credits CF, Pstat Glass/Floor Area: 0.512 Total Modified Loads: 292.22 PASS 7posed Total Baseline Loads: 308.78 I hereby that the and specifications c I ered by Review of the plans and PliE STq , certify plans this calculation are in compliance with the Florida Energy specifications covered by this �� Code. calculation indicates compliance with the Florida Energy Code. ti sirr PREPARED BY: Before construction is completed DATE: a- - this building will be inspected for compliance with Section 553.908 0 * °_ - I hereby certify that this buildin signe in compliance Florida Statutes. �0 with the Florida Energy Cod I WE OWNER/AGENT: BUILDING OFFICIAL: DATE: I I - Compliance requir certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory- aled in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). file C®py... 3/2/2018 1:09 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 7 FnRnn'PAnF_7n17 PROJECT Title: Basile Be�rooms: 3 Address Type: Street Address Building Type: User Coi ditioned Area: 8163 Lot # Owner Name: Basile Total Stories: 2 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Foglia Custom Homes Rotate Angle: 0 Street: 6600 N. Hwy. Al Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: W iole House Fan: City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34949 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site I 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, VERO_BEACH_MUN FL_VERO_BEACH_MUNI 45 90 70 75 299 64 Medium BLOCKS Number Name Area (Volume 1 Block1 2391.858 31860.3 2 Block2 2178.370 31076.5 3 Block3 1989.288 28681.5 4 Block4 1603.140 19755.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 System 1 2391.859 31860.3 Yes 2 1 1 Yes Yes Yes 2 System 2 2178.37 31076.5 76.5 No 0 0 1 Yes Yes Yes 3 System 3 1989.289 28681.5 Yes 4 1 1 Yes Yes Yes 4 System 4 1603.141 •19 55.8 No 2 1 1 Yes Yes Yes FLOORS # Floor Type Space l Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio System 1 290 ft 0 2167.65 ft ---_ 0 0 1 2 Slab -On -Grade Edge Insulatio System 2 107 ft 0 1154.37 ft ____ 0 0 1 3 Slab -On -Grade Edge Insulatio System 3 112 ft 0 1013.34 ft -___ 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V/ # Type Materials I Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 15409 ftZ 0 ftZ Medium i 0.6 No 0.9 No 20 30.3 ATTIC I # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 4669.93 ft N N 3/2/2018 1:09 PM EnergyGauge®(USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 7 I FORM 'R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) System 1 1 Blown 1066.84 ft2 0.11 Wood 2 Under Attic (Unvented) Systl m 2 1 Blown 1024 ft2 0.11 Wood 3 Under Attic (Unvented) System 3 1 Blown 975.95 ft2 0.11 Wood 4 Under Attic (Unvented) Sys iem 4 1 Blown 1603.13 ft2 0.11 Wood WALLS Ornt Adjacent 10 Space Wall lype Cavity Width Et In Height Et In Area Sheathing Framing Solar R-\/Pllle Fraction Ahsor Below rr:;rie% _ 1 S Exterior Concrete Block - Polystyr®ysPA/Mus. tem 1 9 15.5 0 16 0 248.0 ft2 0 0 0.6. 0 2 E Exterior Concrete Block - Polystyreystem 1 9 15.5 0 16 0 248.0 ft2 0 0 0.6 0 _ 3 N Exterior l Concrete Block - PolystynSysem 1 9 15.5 0 13 0 201.5 ft2 0 0 0.6 0 - 4 E Exterior l Concrete Block - Polystyr®ystem 1 9 8.417 0 13 0 109.5 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Polystyr®ystem 1 9 8.5 0 13 0 110.5 ft2 0 0 0.6 0 _ 6 W Exterior Concrete Block - Polystyr®ystem 1 9 10.5 0 13 0 136.5 ft2 0 0 0.6 0 _ 7 S Exterior Concrete Block - Polystyr®y tem 1 9 22.5 0 13 0 292.5 ft2 0 0 0.6 0 _ 8 N Exterior Concrete Block - Polystyreystem 1 9 8.25 0 13 0 107.3 ft2 0 0 0.6 0 _ 9 N Exterior Concrete Block - Polystyrday$tem 1 9 16.25 0 13 0 211.3 ft2 0 0 0.6 0 _ 10 E Exterior Concrete Block - Polystyr®ystem 1 9 8 0 13 0 104.0 ft2 0 0 0.6 0 _ 11 N Exterior Concrete Block - Polystyrfiystem 1 9 16.25 0 13 0 211.3 ft2 0 0 0.6 0 _ 12 N Exterior Concrete Block - Polystyr®ystem 1 9 18.16 0 13 0 236.2 ft2 0 0 0.6 0 13 N Exterior Concrete Block - Polystyr®ystem 1 9 30 0 13 0 390.0 ft2 0 0 0.6 0 _ 14 E Exterior Concrete Block - PolystyriSystem 1 9 6 0 13 0 78.0 ft2 0 0 0.6 0 _ 15 W Exterior Concrete Block - Polystyr®y tem 1 9 6.667 0 13 0 86.7 ft2 0 0 0.6 0 _ 16 $ Exterior Concrete Block - Polystyr®ystem 1 9 16 0 13 0 208.0 ft2 0 0 0.6 0 17 W Exterior Concrete Block - Polystyr®ystem 1 9 14 0 13 0 182.0 ft2 0 0 0.6 0 _ 18 W Exterior Concrete Block - Polystyr�stem 1 9 6.75 0 13 0 87.8 ft2 0 0 0.6 0 19 S Exterior Concrete Block - Polystyr�stem 1 9 6.833 0 13 0 88.8 ft2 0 0 0.6 0 _ 20 W Exterior Concrete Block - Polystyr�stem 1 9 10.5 0 13 0 136.5 ft2 0 0 0.6 0 21 E Exterior Concrete Block - Polystyr�stem 1 9 20.75 0 13 0 269.8 ft2 0 0 0.6 0 _ _ 22 W Exterior Concrete Block - Polystyrestem 1 9 9.5 0 13 0 123.5 ft2 0 0 0.6 0 _ 23 S Exterior Concrete Block - Polystyrfistem 2 9 16 0 13 0 208.0 ft2 0 0 0.6 0 24 E Exterior Concrete Block - Polystyr�stem 2 9 30.83 0 13 0 400.8 ft2 0 0 0.6 0 _ 25 W Exterior Concrete Block - Polystyraystem 2 9 30.83 0 13 0 400.8 ft2 0 0 0.6 0 _ 26 N Exterior Concrete Block - Polystyraystem 2 9 8 0 13 0. 104.0 ft2 0 0 0.6 0 _ 27 E Exterior Concrete Block - Polystyr®ystem 2 9 10 0 13 0 130.0 ft2 0 0 0.6 0 _ 28 W Exterior Concrete Block - Polystyr�stem 2 9 10.58 0 13 0 137.5 ft2 0 0 0.6 0 29 N Exterior Concrete Block - Polystyr®ystem 2 9 16 0 15.66 0 250.7 ft2 0 0 0.6 0 30 S Exterior Concrete Block - Polystyr®ystem 2 9 16 0 15.66 0 250.7 ft2 0 0 0.6 0 31 E Exterior Concrete Block - Polystyrd�stem 2 9 32 0 15.66 0 501.4 ft2 0 0 0.6 0 32 W Exterior Concrete Block - Polystyr@gystem 2 9 32 0 15.66 0 501.4 ft2 0 0 0.6 0 _ 33 N Exterior Concrete Block - Polystyrsystem 3 9 16 0 13 0 208.0 ft2 0 0 0.6 0 34 S Exterior Concrete Block - Polystyri4ystem 3 9 31.83 0 13 0 413.8 ft2 0 0 0.6 0 _ 35 E Exterior Concrete Block - Polystyr®ystem 3 9 31.83 0 13 0 413.8 ft2 0 0 0.6 0 36 W Exterior Concrete Block - Polystyr�stem 3 9 31.83 0 13 0 413.8 ft2 0 0 0.6 0 3/2/2018 1:09 PM EnergyGauge(D USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 7 FORM'R405-2017 WALLS Adjacent Sp To Well Type ce Cavity Width Height Sheathing Framing Solar Belo w 37 E Exterior Concrete Block - Polystyr®ystem 3 9 10 0 15.66 0 156.7 ft2 0 0 0.6 0 38 N Exterior Concrete Block - Polystyr®ystem 3 9 8 0 15.66 0 125.4 ft2 0 0 0.6 0 39 S Exterior Concrete Block - Polystyraystem 3 9 8 0 15.66 0 125.4 ft2 0 0 0.6 0 _ 40 E Exterior Concrete Block - PolystynRystem 3 9 16.33 0 15.66 0 255.9 ft2 0 0 0.6 0 _41 W Exterior Concrete Block - PolystyrdRystem 3 9 28 0 15.66 0 438.8 ft2 0 0 0.6 0 _42 S Exterior Concrete Block - Polystyr®ys em 3 9 17.33 0 15.66 0 271.6 ft2 0 0 0.6 0 _43 E Exterior Concrete Block - Polystyr®ys em 3 9 16 0 15.66 0 250.7 ft2 0 0 0.6 0 _44 S Exterior Concrete Block - Polystyr®ystem 3 9 6.583 0 15.66 0 103.1 ft2 0 0 0.6 0 _45 W Exterior Concrete Block - PolystynRy+rn 3 9 16.33 0 15.66 0 255.9 ft2 0 0 0.6 0 46 N Exterior Concrete Block - Polystyr®ys em 4 9 10 0 15.66 0 156.7 ft2 0 0 0.6 0 _47 E Exterior Concrete Block - Polystyr®ys em 4 9 16 0 15.66 0 250.7 ft2 0 0 0.6 0 48 N Exterior Concrete Block - Polystyr®ys em 4 9 17.58 0 15.66 0 275.5 ft2 0 0 0.6 0 _49 E Exterior Concrete Block - Polystyr®yslIem 4 9 6 0 15.66 0 94.0 ft2 0 0 0.6 0 50 W Exterior Concrete Block - Polystyr®ystem 4 9 17.58 0 15.66 0 275.5 ft2 0 0 0.6 0 T 51 E Exterior Concrete Block - Polystyr®ystllem 4 9 16 Q 15.66 0 250.7 ft2 0 0 0.6 0 52 S Exterior Concrete Block - Polystyr®ystem 4 9 8 0 15.66 0 125.4 ft2 0 0 0.6 0 _ 53 E Exterior Concrete Block - Polystyr®ys em 4 9 11 0 15.66 0 172.4 ft2 0 0 0.6 0 54 W Exterior Concrete Block - Polystyr®ys em 4 9 10 0 15.66 0 156.7 ft2 0 0 0.6 0 _55 W Exterior Concrete Block - Polystyr®yslem 4 9 8 0 15.66 0 125.4 ft2 0 0 0.6 0 56 W Exterior Concrete Block - Polystyr®yskem 4 9 12 0 15.66 0 188.0 ft2 0 0 0.6 0 _ 57 S Exterior Concrete Block - Polystyr®yslltem 4 9 8 0 15.66 0 125.4 ft2 0 0 0.6 0 _ 58 N Exterior Frame - Wood System 4 19 16 0 5 0 80.0 ft2 0 0.23 0.6 0 59 S Exterior Frame - Wood Sys em 4 19 16 0 5 0 80.0 ft2 0 0.23 0.6 0 _60 E Exterior Frame - Wood Sys em 4 19 16 0 5 0 80.0 ft2 0 0.23 0.6 0 61 W Exterior Frame - Wood Sys�em 4 19 16 0 5 0 80.0 ft2 0 0.23 0.6 0 DOORS # Ornt Door Type Spai a Storms U-Value Area FtWidth In FHeightln 1 W Wood Systel 1 None .39 3.2 8 25.4 ft2 WINDOWS Orientation shown is the entered, Pro osed orientation. Wall I Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 TIM Low-E Double Yes 0.63 0.2 Y 143.3 ft2 2.667 ft 0 2.667 ft 0 None None 2 S 1 TIM Low-E Double Yes 0.36 0.28 Y 38.2 ft2 2.667 ft 0 0.883 ft 0 None None 3 E 2 TIM Low-E Double Yes 0.63 0.2 Y 143.3 ft2 2.667 ft 0 2.667 ft 0 None None 4 E 2 TIM Low-E Double Yes 0.36 0.28 Y 38.2 ft2 2.667 ft 0 0.883 ft 0 None None 5 E 4 TIM Low-E Double Yes 0.45 0.21 Y 40.0 ft2 2.667 ft 0 4.667 ft 0 None None 6 E 4 TIM Low-E Double Yes 0.36 0.28 Y 10.7 ft2 2.667 ft 0 0.883 ft 0 None None 7 S 5 TIM Low-E Double Yes 0.45 0.21 Y 21.3 ft2 2.667 ft 0 4.833 ft 0 None None 8 S 5 TIM Low-E Double Yes 0.36 0.28 Y 7.1 ft2 2.667 ft 0 0.883 ft 0 None None 9 S 7 TIM Low-E Double Yes 0.36 0.28 Y 53.3 ft2 2.667 ft 0 2 ft 0 in None None 3/2/2018 1:09 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 7 FORM'R405-2017 Orientation WINDOWS . shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor $HGC Imp Area Depth Separation Int Shade Screening 10 N 8 TIM Low-E Double Yes 0.36 0.28 Y 26.7 ft2 2.667 ft 0 4.5 ft 0 in None None !T 11 N 9 TIM Low-E Double Yes 0.45 0.21 Y 26.7 ft2 2.667 ft 0 12.5 ft 0 i None None 12 E 10 TIM Low-E Double Yes 0.45 0.21 Y 40.0 ft2 2.667 ft 0 12.5 ft 0 i None None 13 N 12 TIM Low-E Double Yes 0.45 0.21 Y 53.3 ft2 2.667 ft 0 12.5 ft 0 i None None 14 N 13 TIM Low-E Double Yes 0.45 0.21 Y 26.7 ft2 2.667 ft 0 12.5 ft 0 i None None 15 N 13 TIM Low-E Double Yes 0.36 0.28 Y 126.0 ft2 2.667 ft 0 1 ft 0 in None None 16 E 14 TIM Low-E Double YES 0.45 0.21 Y 26.7 ft2 2.667 ft 0 12.5 ft 0 i None None 17 S 16 TIM Low-E Double Yes 0.36 0.28 Y 96.0 ft2 2.667 ft 0 2.667 ft 0 None None 18 W 17 TIM Low-E Double Yes 0.45 0.21 Y 21.0 ft2 2.667 ft 0 12.5 ft 0 i None None 19 W 18 TIM Low-E Double Yes 0.45 0.21 Y 21.0 ft2 2.667 ft 0 12.5 ft 0 i None None 20 S 19 TIM Low-E Double Y s 0.45 0.21 Y 40.0 ft2 2.667 ft 0 12.5 ft 0 i None None 21 W 20 TIM Low-E Double YES 0.45 0.21 Y 40.0 ft2 2.667 ft 0 12.5 ft 0 i None None 22 E 21 TIM Low-E Double YE s 0.36 0.28 Y 76.7 ft2 2.667 ft 0 12.5 ft 0 i None None 23 E 21 TIM Low-E Double YE s 0.43 0.16 Y 24.0 ft2 2.667 ft 0 4.833 ft 0 None None 24 E 21 TIM Low-E Double YE s 0.36 0.28 Y 8.0 ft2 2.667 ft 0 0.883 ft 0 None None 25 W 22 TIM Low-E Double Y s 0.45 0.21 Y 26.7 ft2 2.667 ft 0 12.5 ft 0 i None None 26 S 23 TIM Low-E Double Y;s 0.43 0.16 Y 24.0 ft2 2.667 ft 0 12.5 ft 0 i None None • 27 E 24 TIM Low-E Double Yes 0.63 0.2 Y 286.6 ft2 4 ft 0 in 0.5 ft 0 in None None 28 W 25 TIM Low-E Double Yes 0.43 0.16 Y 60.0 ft2 2.667 ft 0 12.5 ft 0 i None None 29 W 25 TIM Low-E Double Yes Q.36 0.28 Y 60.0 ft2 2.667 ft 0 12.5 ft 0 i None None -� 30 W 25 TIM Low-E Double Yes 0.45 0.21 Y 53.3 ft2 2.667 ft 0 12.5 ft 0 i None None 31 N 26 TIM Low-E Double Ygs 0.45 0.21 Y 26.7 ft2 2.667 ft 0 12.5 ft 0 i None None 32 E 27 TIM Low-E Double Yes 0.43 0.16 Y 24.0 ft2 10.667 ft 2 ft 0 in None None T 33 W 28 TIM Low-E Double Yes 0.45 0.21 Y 21.3 ft2 2.667 ft 0 12.5 ft 0 i None None 34 N 29 TIM Low-E Double Y s 0.45 0.21 Y 32.0 ft2 10 ft 0 in 1.5 ft 0 in None None 35 S 30 TIM Low-E Double Y s 0.45 0.21 Y 32.0 ft2 2.667 ft 0 1.5 ft 0 in None None 36 E 31 TIM Low-E Double Yes 0.36 0.28 Y 280.0 ft2 2.667 ft 0 1.5 ft 0 in None None 37 W 32 TIM Low-E Double Ygs 0.43 0.16 Y 40.0 ft2 6 ft 0 in 1.5 ft 0 in None None 38 W 32 TIM Low-E Double Yes 0.45 0.21 Y 42.7 ft2 2.667 ft 0 1.5 ft 0 in None None 39 W 32 TIM Low-E Double Yes 0.45 0.21 Y 64.0 ft2 6 ft 0 in 1.5 ft 0 in None None 40 N 33 TIM Low-E Double Yes 0.43 0.16 Y 48.0 ft2 2.667 ft 0 12.5 ft 0 i None None -� 41 N 33 TIM Low-E Double Yes 0.64 0.15 Y 31,5 ft2 2.667 ft 0 12.5 ft 0 i None None 42 S 34 TIM Low-E Double Yes 0.64 0.15 Y 137.5 ft2 2.667 ft 0 12.5 ft 0 i None None 43 S 34 TIM Low-E Double Yes 0.45 0.21 Y 28.0 ft2 2.667 ft 0 12.5 ft 0 i None None 44 E 35 TIM Low-E Double Yes 0.64 0.15 Y 275.0 ft2 2.667 ft 0 12.5 ft 0 i None None 45 W 36 TIM Low-E Double Yes 0.64 0.15 Y 101.8 ft2 2.667 ft 0 12.5 ft 0 i None None 46 W 36 TIM Low-E Double Yes 0.45 0.21 Y 28.0 ft2 2.667 ft 0 12.5 ft 0 i None None 47 E 37 TIM Low-E Double Yes 0.45 0.21 Y 12.0 ft2 2.667 ft 0 1.5 ft 0 in None None 48 N 38 TIM Low-E Double Yes 0.45 0.21 Y 32.0 ft2 2.667 ft 0 1.5 ft 0 in None None 49 E 40 TIM Low-E Double Yes 0.36 0.28 Y 112.0 ft2 2.667 ft 0 1.5 ft 0 in None None 50 S 39 TIM Low-E Double Yes 0.63 0.2 Y 48.0 ft2 15.667 ft 1.5 ft 0 in None None 51 W 41 TIM Low-E Double Yes 0.63 0.2 Y 112.0 ft2 8 ft 0 in 1.5 ft 0 in None None 3/2/2018 1:09 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 7 i:(1RhA `PAnc,-gn17 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 52 W 41 TIM Low-E Double Yes 0.45 0.21 Y 21.3 ft2 2.667 ft 0 1.5 ft 0 in None None 53 E 43 TIM Low-E Double Yes 0.63 0.2 Y 112.0 ft2 8 ft 0 in 1.5 ft 0 in None None 54 S 42 TIM Low-E Double Yes 0.36 0.28 Y 112.0 ft2 2.667 ft 0 1.5 ft 0 in None None 55 S 44 TIM Low-E Double Yes 0.45 0.21 Y 20.0 ft2 2.667 ft 0 1.5 ft 0 in None None Is 56 W 45 TIM Low-E Double Y 0.45 0.21 Y 20.0 ft2 2.667 ft 0 1.5 ft 0 in None None 57 E 47 TIM Low-E Double Y s 0.36 0.28 Y 72.0 ft2 6 ft 0 in 1.5 ft 0 in None None 58 E 47 TIM Low-E Double Yes 0.43 0.16 Y 24.0 ft2 6 ft 0 in 1.5 ft 0 in None None 59 N 48 TIM Low-E Double Yes 0.36 0.28 Y 72.0 ft2 2.667 ft 0 1.5 ft 0 in None None T 60 N 48 TIM Low-E Double Y s 0.45 0.21 Y 20.0 ft2 2.667 ft 0 1.5 ft 0 in None None 61 E 49 TIM Low-E Double Y�s 0.45 0.21 Y 21.3 ft2 2.667 ft 0 1.5 ft 0 in None None 62 W 50 TIM Low-E Double Y s 0,45 0.21 Y 21.3 ft2 2.667 ft 0 1.5 ft 0 in None None 63 W 50 TIM Low-E Double Yes 0.45 0.21 Y 20.0 ft2 2.667 ft 0 1.5 ft 0 in None None 64 E 51 TIM Low-E Double YI s 0.43 0.16 Y 24.0 ft2 6 ft 0 in 1.5 ft 0 in None None 65 E 51 TIM Low-E Double Yes 0.36 0.28 Y 72.0 ft2 2.667 ft 0 1.5 ft 0 in None None 66 S 52 TIM Low-E Double YI s 0.63 0.2 Y 48.0 ft2 2.667 ft 0 1.5 ft 0 in None None 67 E 53 TIM Low-E Double Y:s 0.45 0.21 Y 12.0 ft2 8 ft 0 in 1.5 ft 0 in None None 68 W 54 TIM Low-E Double Yes 0.45 0.21 Y 21.3 ft2 2.666667 1.5 ft 0 in None None 69 W 56 TIM Low-E Double Y�s 0.45 0.21 Y 20.0 ft2 2.667 ft 0 1.5 ft 0 in None None 70 S 57 TIM Low-E Double Yes 0.45 0.21 Y 20.0 ft2 2.667 ft 0 1.5 ft 0 in None None 71 N 58 TIM Low-E Double YI s 0.45 0.21 Y 60.0 ft2 2.667 ft 0 0.5 ft 0 in None None 72 S 59 TIM Low-E Double YIlIes 0.45 0.21 Y 60.0 ft2 2.667 ft 0 0.5 ft 0 in None None 73 E 60 TIM Low-E Double Yes 0.45 0.21 Y 60.0 ft2 2.667 ft 0 0.5 ft 0 in None None 74 W 61 TIM Low-E Double ies 0.45 0.21 Y 60.0 ft2 2.667 ft 0 0.5 ft 0 in None None 7 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000433 9281.2 509.52 958.24 .4003 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:9 45.5 kBtu/hr 1 sys#1 2 Electric Heat Pump/ Split HSPF:9 45.5 kBtu/hr 2 sys#2 3 Electric Heat Pump/ Split HSPF:9 45.5 kBtu/hr 3 sys#3 4 Electric Heat Pump/ Split HSPF:9 37 kBtu/hr 4 sys#4 3/2/2018 1:09 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 7 36T]IT, ENWITM- •illIFA ' COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts _ 1 Central Unit/ Split SEER: 16 45.5 kBtu/hr 1365 cfm 0.75 1 sys#1 2 Central Unit/ Split SEER: 16 45.5 kBtu/hr 1365 cfm 0.75 2 sys#2 3 Central Unit/ Split SEER: 16 45.5 kBtu/hr 1365 cfm 0.75 3 sys#3 4 Central Unit/ Split SEER: 15.5 34.2 kBtu/hr 1026 cfm 0.75 4 sys#4 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless System i1 0.95 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model I # Area Volume FEF None None ff' DUCTS / ---- Supply ---- -- eturn ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 System 1 6 408.13 Systen 1 102.03 Default Leakage System 1 (Default) (Default) 1 1 2 System 2 6 408.13 Systen 2 102.03 Default Leakage System 2 (Default) (Default) 2 2 3 System 3 6 408.13 Systen 3 102.03 Default Leakage System 3 (Default) (Default) 3 3 4 System 4 6 408.13 Systen, 4 102.03 Default Leakage System 4 (Default) (Default) 4 4 TEMPERATURES Programabl[e Ceiling Fans: ]Thermosta[t:jjY [[ ]] Feb Mar Ap [ ] Jul Aug [X] oct Nov Dec Heating f X] Jan f X] [X] �j Jun JM rjrj [ ]Sep �i �X� Nov DecVenting [[ ]] Jan [[ ]] Feb [[X]] Mar Apr EX] L ay Jun ]Jul Aug [ ]Sep Oct Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 4 5 6 7 8 9 10 11 12 Cooling (VUD) 80 718 78 78 78 78 78 78 78 78 PM 80 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 718 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION i Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Fans/ERV 600 60,10 575 75 2 - Electric Heat Pump 35% 2 - Central Unit 3/2/2018 1:09 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 7 of 7 FORMA R405-2017 ENERGY PERFORMANCE LEVEL (EPL) - DISPLAY CARD ESTIMATED ENFRGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. 6600 N. Hwy. A1A, Fort Pierce, FL, 34949 1. New construction or existing New (From Flans) 9. Wall Types Insulation Area a. Concrete Block - Polystyrene Bead Aggt=9.0 12382.00 ft2 2. Single family or multiple family Single-family) b. Frame - Wood, Exterior R=19.0 320.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 4669.90 ft2 6. Conditioned floor area (ft2) 8163 b. N/A R= ft2 c. N/A R= ft2 7. Windows- Description Ara g 11. Ducts R ft2 a. U-Factor: Dbl, U=0.36 1260.$0 ft� 2 additional duct system(s) 6 408.15 SHGC: SHGC=0.28 b. Sup: System 2, Ret: System 2, AH: System 2 6 408.13 b. U-Factor: Dbl, U=0.45 1212.�0 ft2 c. Sup: System 3, Ret: System 3, AH: System 3 ' (see detail SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.63 893. 1 ft2 a. Central Unit 45.5 SEER:16.00 SHGC: SHGC=0.20 b. Central Unit 45.5 SEER:16.00 2 additional cooling systems (see details) ' d. U-Factor: other (see details) 811.1 8 ft2 13. Heating systems kBtu/hr Efficiency SHGC: other (see details) a. Electric Heat Pump 45.5 HSPF:9.00 Area Weighted Average Overhang Depth: 3.41189 ft. b. Electric Heat Pump 45.5 HSPF:9.00 Area Weighted Average SHGC: 0.218 2 additional heating systems (see details) 8. Floor Types Insulation Area 14. Hot water systems Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 4335.40 ft2 a. Propane EF: 0.95 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits CF, Pstat I certify that this home has complied with the Florid Construction through the above energy saving feat in this home before final inspection. Otherwise, a r based on installed Code compliant features. Builder Signature: Address of New Home: a Energy Efficiency Code for Building Tres which will be installed (or exceeded) iew EPL Display Card will be completed Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/2/2018 1:12 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1