HVAC LOADS
Rhvac Residential,q& Light Commercial HVAC Loads Elite Software Development, Inc.` o . as Smith Heating & A/C Basile ..• „ ..: a , _. ,., . �.. . > - �-.., � � � � , . Project Report :Gerieral;Pro ecf°liiformation r E` Project Title: Basile Designed By: Smith Services, Inc. Project Date: Wednesday, September 20, 2017 Client Name: Foglia Custom Homes Client Address: 1705 19th Place, Ste. F-2 Client City: Vero Beach, FL. 32960 Client Phone: (954) 444-6152 Company Name: Smith Services, Inc. Company Representative: Mike Thornton Company Address: 1306 29th Street Company City: Vero Beach, FL. 32960 Company Phone: (772) 770-3300 Reference City: Foy rt Pierce, Florida Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Out oor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 95 78 4I7% 50% 75 53 ,. r ,A h Sref M h Check Figures _ h m ,rGL V� E-` Total Building Supply CFM: 5,731 CFM Per Square ft.: 0.702 Square ft. of Room Area: 8,163 Square ft. Per Ton: 522 Volume (ft'): 115,259 Buildin aLoads .>,u .,wh .<.,r x ,r.y.,, ,� ,. , Total Heating Required Including Ventilation Air: 1107,148 Btuh 107.148 MBH Total Sensible Gain: 1140,755 Btuh 83 % Total Latent Gain: 28,223 Btuh 17 % Total Cooling Required Including Ventilation Air: 68,978 Btuh 14.08 Tons (Based On Sensible + Latent) 15.64 Tons (Based On 75% Sensible Capacity) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Basile.rh9 Friday, March 02, 2018, 1:20 PM Residential & Light Comercial HVAC Loads Elite Software Development, Inc Rhvac m Smith H& A/C ' S Basile eating Vero Beach; �L�3296b _ _ Miscellaneous Report System 1 Systern utdoor- � Outdooi �°�� � `Outdoor InddorI Indoor -` Gcams "�,` DBulb V11et�Bul'b� � � �Re[ Harn �° Rel:Hiam }�' ° "��= D 'Bulb Difference° Input Data:„�` .,� Winter: 42 39.4 80% n/a 70 n/a Summer: 95 I 78 47% 50% 75 52.90 System 2 System2 ! E , Outdoor Outdoors Outdoor' Indoor Indoor s Grams yt-,F3el Hums ReLHum,,,:.�,D Differences In Winter: 42 39.4 80% n/a 70 n/a Summer: 95 I 78 47% 50% 75 52.90 System 3 System 3 ��Outdoor�� Outdoor `a r Outdoor Indoor] �� Indoor' Grams: InputData�,..6 .,Bulb�1/VetBulb °ReLHurn :}. Rel;Hum_ D :,Bulb ., .;°Difference.y Winter: 42 39.4 80% n/a 70 n/a Summer: 95 I 78 47% 50% 75 52.90 Systerp 4 System 4 n „Outdoor Outdoor "n Outdoof Indoor)9 IndoorF Grams; 0o a ° ". Bulb Rel Hum Re(H' m i Dry Bulb Dq e"r'enc I'n ut Data =.P,.. . s . ,, .. , . D_ ,Bnulb ,_ ,,, .Wet , _ Winter: 42 39.4 80% n/a 70 n/a Summer: 95 I 78 47% 50% 75 52.90 1�ye� Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.0800 in.wg./100 ft. 0.0800 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. N. Winter Summer Infiltration Specified: 0.100 AC/hr 0.100 AC/hr 192 CFM 192 CFM_ Infiltration Actual: 0.100 AC/hr 0.000 AC/hr Above Grade Volume: X 115,259 Cu.ft. X 115,259 Cu.ft. 11,526 Cu.ft./ r 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 192 CFM 0 CFM Total Building Ventilation: 0 CFM 672 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 35.94 = (0.68 X 0.999 X 52.90 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1,10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.100 AC/hr (53 CFM) Summer Infiltration Specified: 0.100 AC/hr (53 CFM) ---System 2--- Infiltration & Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 315.94 = (0.68 X 0.999 X 52.90 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 310.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.100 AC/hr (52 CFM) II Summer Infiltration Specified: 0.100 AC/hr (52 CFM) ---System 3--- Infiltration & Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 35.94 = (0.68 X 0.999 X 52.90 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.100 AC/hr (47 CFM) Summer Infiltration Specified: 0.100 AC/hr (47 CFM) I C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Basile.rh9 Friday, March 02, 2018, 1:20 PM Load Preview Report Net Rep n. i Sen Let Net Sen Sys Htg SS: Clg Sys Act Duct Scope Ton Ton /Ton' Area Gain Gain Gain Loss CFM CFM CFM Size Building 14.08, 15.64 522 8,163' 140,755 28,223 168,978 107,148 1,393.' 5,731 i 5,731 System 1 4.02 4,47 535 2,392 40,240 ; 7,971^ 48,211 35,187 , 457 F,1645_II 1,645 14x21 Ventilation 4,079, 6,670' 10,7491 0 Zone 1 -Clg.: 48%, Htg.: 55% 1,067 18,733 400 19,133 19,287 251 852 i 852 12x14 1-Master Bedroom 240 10,443 400, 10,843 ` 7,846 102 475; 475 2-9 2-His Bath 130 2,388 0 2,388 2,400 31 ,t.109, 109 1-6 3-His Closet 89 899 0 899, 1,762 231,' Y 4,1q 41, 1-4 4-Master Hallway 158 1,412 ' 0 � 1,412 ' 2,274' 30 641 64 1-5 5-Vestibule 35 47 0 47 51 1 N ,,. • 2i 2 1-4 6-Her WC 35 561 0 561 ' 8405 11 `: 2ti ` 26 1-4 7-Her Bath 163 2,330 0• 2,330 2,652 34 ¢ 106. 106 1-6 8-Her Closet 217 653 0 653 1,462 ; 19 .r 30" 30 1-4 Zone 2 - Clg.: 52%, Htg.: 45% 11325 20,453 901 21,354 , 15,900 207 j 531111 931 12x16 9-Den 295 1,129 0 1,129 1,845 : 24 ; DJ 51 ^ 51 1-4 10-Hall 1 73 0 0' 0 0 0 1m' >` O 0 0-0 11-Hall2 200 5,833, 0 5,833, 6,734 88,p 265l 265 1-10 12-Laundry 121 1,643 0' 1,643 1,217 16*1 751i 75 1--5 13-Hall 3 116 0 0 0 0 0�_:_, A:! 0 1--0 14-Vestibule 59, 1,005 0 1,005 710 9'1`.,f� "46ji 46 1-4 15-Powder Room 72 2,638 0 2,638, 2,058. 27 t ° " 120 i 120 1-6 16-Kitchen 389 8205 901 9,106 3,336, 43 j,.3T3;j 373 4-6 System 2 3.58 4.04 539 2,178 36,403 6,510 t 42,913 24,756 322 ^1 475 1,475 14x19 Ventilation 3,981 6,510 10,491 0 Zone 1 2,178 32,422 0 32,422 . 24,756 , 322 1,4.75;f 1,475 14x19 17-Great Room/Entry 982 14,625 0 14,625, 12,850 167 , 665'; 665 4-8 18-Storage 01 86 509 0 509, 967 13 § 23a 23 1--4 19-Bar 88 821 0, 821 1,010 13 �.3V 37 1-4 29-2nd Floor Balcony 1,024. I 16,467 0 16,467 9,929 129 ` 749,1 749• 44 System 3 3.98 4,45 447 40,044 ' 7,725 47,769 ' 31,225 406 ~1 656;'j 1,656 14x21 Ventilation �,989 3,650 5,967 9,617` 0, Zone 1 -CIg.: 48%, Htg.: 56°10 013 19,239 958 20,197 I 17,640 229 ; 875:1 875 12x15 20-1/0 Great Room ,013 19,239 958 20,197 , 17,640 229 875.E 875 4-9 Zone 2 - Clg.: 52%, I Itg.: 44% 976 20,498, 800' 21,298 , 13,585 177 E„ _933I, 933 12x16 30-Bathroom 02 139 675 0 675 729 9.1 31 :1 31 1-4 31-Bedroom 02 308 5,375 4001 5,775 3,710 48 ?'� 245; 245 2-7 32-Hallway 144 6,567 0 6,567 3,290 43! °° 299" 299 1-10 33-Bedroom 03 i 277 5,996 400 6,396 4,363 57 273 273 2-7 34-Bathroom03 108 1,885 0 1,885 1,493 19 8@ 86 1-5 System 4 2.51 2.67 599 1 ij1603 24,068 6,017 30,085 15,980 208 ` 95, jr 955 12x16 Ventilation 3,068 5,017, 8,085` 0 Zone 1 - Clg.: 74%, Htg.: 76% 1 279 17,481 , 1,000 18,481 12,180 158 { 795aj 795 1 0x1 7 21-Office 1237 4,662 2001 4,862; 2,222' 29 f_ 212! 212i 1-9 22-Exercise '299' 4,236 400 4,636' 3,561 46 j; .193 193' 2-6 23-Vestibule 37 50 0 50, 54 1 2�v i 2. 1 24-Bedroom 04 301 5,595 400 5,995 2,977 39 1"'� 255, 255 2-7 25-Bath 04 21 837 0 837, 752 10 1:"r 38! 38 1-4 26-Hallway 114 664 0 664 799 10i 30 30 1-4 27-Storage 02 68 305 0 305 427 6 Y, 14 14 1-4 28-Bath05 102' 1,132` 0 1,132- 1,388 18p 52?; 52 1-4 Zone 2 - Clg.: 26%, Htg.: 24% 324 6,268 0, 6,268 3,800 49 ( ", 285,, 285 7x7 C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Basile,rh9 Friday, March 02, 2018, 1:20 PM Rhvac Residential'&,Light,Commercial HVAC Loatls i 3' Elite Software Development; Inca Srpith Heat��g & AIC �' Basile _ y Vero BeachL 32980 Total Building Summary Loads ComponentPi ' Sens Lat Sen =' .r Total. QAreal r� j�e.� L'oss�,.,,. '�Galnrq Descrl tiori,..- x� .ua"°�'.4 s�'Gm.�... _ A1A-Al: Glazing -Sliding Glass Door, Low- E Impact, 893.2 15,756 0 21,460 21,460 alum. clad wood/no Break, u-value 0.63, SHGC 0.2 C1 B-MAWFenb: Glazing -Fixed sash, Mono, Alum., lov -e, 1260.8 12,705 0 29,826 29,826 no break, u-value 0.36, SHGC 0.28 C1A-MAWFe: Glazing -operable casement, alum, low-e, 1212.7 15,277 0 25,753 25,753 no break, u-value 0.45, SHGC 0.21 C1 OC-W: Glazing -French Door, Heat Absorbing, 268 3,227 0 4,856 4,856 Aluminum Frame, without Break, u-value 0.43, SHGC 0.16 A10A-m: Glazing-Windoor alum., Low-E, impact, u-val a 545.8 9,780 p 12,959 12,959 0.64, SHGC 0.15 11 D: Door -Wood - Solid Core 25.3 277 0 306 306 A13A-R-13.1: Wall -Block, Custom, 8" CMU R-9 core -fill 8415.4 17,908 0 14,324 14,324 w/4.1 Fi-foil (R-13.1) 12E-Osw: Wall -Frame, R-19 insulation in 2 x 6 stud 80 152 0 120 120 cavity, no board insulation, siding finish, wood stud 18131-8-19o: Roof/Ceiling-Roof Joists Between Roof I 4669.9 6,802 0 6,313 6,313 Deck and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, White or Light Color Asphali Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-19 open cell 1/2- lb. spray foam, 5 inches in 2 x 8 joist cavity 22A-ph: Floor -Slab on grade, No edge insulation, no 509 19,353 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 101,237 0 115,917 115,917 People: 14 2,800 3,220 6,020 Equipment: 1,259 6,840 8,099 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 192, Summer CFM: 0 5,911 0 0 0 Ventilation: Winter CFM: 0, Summer CFM: 672-_.._.._.._...-__._.......____._.._.._._____-_..._...___-.._.._....-._.._0...__._.....24,164 _.___...._14,778 38,942 Total Building Load Totals: 107,148 28,223 140,755 168,978 ��. rr�� Gj.. Check.Fi uresF ..r r 94 Total Building Supply CFM: 5,731 CFM Per Square ft.: 0.702 Square ft. of Room Area: 8,163 Square ft. Per Ton: 522 Volume (ft3): 115,259 ., bd� Total Heating Required Including Ventilation Air: 107,148 Btuh 107.148 MBH Total Sensible Gain: 140,755 Btuh 83 % Total Latent Gain: 28,223 Btuh 17 % Total Cooling Required Including Ventilation Air: 168,978 Btuh 14.08 Tons (Based On Sensible + Latent) 15.64 Tons (Based On 75% Sensible Capacity) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Editioh, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Basile.rh9 Friday, March 02, 2018, 1:20 PM Rhv_ac Res�dentialy&Light Commercial HVAC Loads R d Elite Software Development, Inca` .w System 9 Room Load Summary r d 3 p,r 3 Htg, Min RUr� Run Clg *: Clg Mini Act. r RoompSens Htg �{ Duct, Sens Lat CIg Sys , 4Duct,,= 7 Btuh CFM t .; ,. S,ize Vel x..,,Bfiih, , : Btuh_ CFM :CFIUI; �° ---Zone 1--- 1 Master Bedroom 240 7,846 102 2-9 538 10,443 400 475 475 2 His Bath 130 2,400 31 1-6 553 2,388 0 109 109 3 His Closet 89 1,762 23 1-4 469 899 0 41 41 4 Master Hallway 158 2,274 30 1-5 471 1,412 0 64 64 5 Vestibule 35 51 1 1-4 25 47 0 2 2 6 Her WC 35 840 11 1-4 292 561 0 26 26 7 Her Bath 163 2,652 34 1-6 540 2,330 0 106 106 8 Her Closet 217 1,462 19 1-4 340 653 0 30 30 _ Zone 1 subtotal 1,067 _ 19,287 _ 251 18,733 400 852 852 ---Zone 2--- 9 Den 295 1,845 24 1-4 589 1,129 0 51 51 10 Hall 73 0 0 0-0 0 0 0 0 0 11 Hall 200 6,734 88 1-10 487 5,833 0 265 265 12 Laundry 121 1,217 16 1-5 548 1,643 0 75 75 13 Hall 3 116 0 0 1-0 0 0 0 0 0 14 Vestibule 59 710 9 1-4 524 1,005 0 46 46 15 Powder Room 72 2,058 27 1-6 611 2,638 0 120 120 16 Kitchen 389 3,336 ---- 43 4-6 475 ---....._........__....-_.................__..-. -- 8,205 901 373 373 - - Zone 2 subtotal---- 1,325 15,900 207 20,453 _ 901 - -- 931 931 - -- Ventilation 0 4,079 6,670 v _ System 1 total 2,392 _35,187 57 --- .............................. - 40,240 7,971 1,645 _1,645 -- .. System 1 Main Trunk Size: 1421 in. Velocity: 806 ft./min Loss per 100 ft.: 0.075 in.wg _._.....__........ _...................... _.._. _ -- --- ._....-_.-...._..-......_-_... --._...--. Note: Since the system is multizone, the Peak Fenestration ----- Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sI to equal the totals at the system level. Room and zone�sensible nsible gains and airflows for cooling shown above are not intended gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load Procedure + Excursion" method. "Cooling.S stem Summa` " ^.,�_Coolmg Seislble/Latent = Sensible `Latent Total Tons lit, °,���a ����,Btuh �:.�k �,��Btuh,, Net Required: 4.02 83% / 1i7% 40,240 7,971 48,211 Recommended: 4.47 75% / 25% 40,240 13,413 53,654 ,,E uipmeWData Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a I 0 Btuh Latent Capacity: n/a I i 0 Btuh C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Basile.rh9 Friday, March 02, 2018, 1:20 PM • I Rhvac Resitlential & Gght Commercial HVAC Loads Elite Software Development, Inc Smith Heati�ig & � s Basile ,._ _. Vero;Beach;''FL 32960 w , {+_ Pa e'47= System 2 Room Load Summary 9 Mm ¢s xRtir`x`Run PCI ` CI Min Act: 9 9 `Room i °�' Area Sense( Htg Duct Duct ` Sens La t " "Ctlg Sys` " " CFM' Size' Vel,,. ' ` '" Btuh CFM CFM N'o,,Name °SF Btuhi .Btuh, ---Zone 1--- 17 Great Room/Entry 982 12,850 167 4-8 477 14,625 0 665 665 18 Storage 01 86 967 13 1-4 265 509 0 23 23 19 Bar 86 1,010 13 1-4 428 821 0 37 37 -1,024 _9,929 129 4-8 537 29 2nd Floor Balcony-_____ _ - - ----- ...................._._.......- - - - ......_— 16,467 0 749 749 --._...................—-._... --... - Ventilation 0 3,981 6,510 System 2 total _ 2,178 _ 24,756 322 _ 36,403 6,510 1,475 1,475 System 2 Main Trunk Size: 14x19 in. Velocity: 799 ft./min Loss per 100 ft.: 0.077 in.wg Coolm S.sterri:Siamma h wk ff i.. ,rb V Coo(mg Sensible/Latent r i, Sensible W Latent Total , a ' .=NTonswBtuh, =`,s., a�.`�,;° aBtuh�... Net Required: 3.58 85016 / 15016 36,403 6,510 42,913 Recommended: 4.04 75% /I25% 36,403 12,134 48,538 merit Data ;; °s R y n Heating System Coolinq System Type: Natural Gas urnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a I I I I I I 0 Btuh C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Basile.rh9 Friday, March 02, 2018, 1:20 PM I Rhyap Residential & Ught Commercial HVAC Loads Eht Saftvyare Development, Inc Basile. Smith. 10d� Vero"Beach;FL ,p"�_ . .32960. , Pa a.& System 3 Room Load Summary g tHtg Min RunaRun ,k > Cog Clg , v. Mm Act; Sens 4Htg Duct Duct Senn Lat Clg Sys; ;PArea No` Name s SF , Btuti "CFM. ° Size Vel Bt it . Btuh e ACFM CFIVI - � ---Zone 1--- 229 20 1/0 Great Room 1,013 17,640 4_-9 495 19,239 958 875 875 Zone 1 subtotal 1,013 17,640 229 19,239 958 875 875 ---Zone 2--- ' 30 Bathroom 02 139 729 9 1-4 352 675 0 31 31 $1 Bedroom 02 308 3,710 48 2-7 458 5,375 400 245 245 32 Hallway 144 3,290 43 1-10 548 6,567 0 299 299 33 Bedroom 03 277 4,363 57 2-7 510 5,996 400 273 273 34 Bathroom 03 108 1,493 19 1-5 629 1,885 _-- _ 0 — 86 _—_ 86 Zone 2 subtotal 976 13,585 77 20,498 800 933 _ 933 Ventilation 0 3,650 5,967 _ System 3 total 1,989 31,225 406 40,044 7,725 1,656 1,656 System 3 Main Trunk Size: 14x21 in. Velocity: 811 ft./min Loss per 100 ft.: 0.076 in.wg ...... Note:- Since the system is multizone, the Peak Fenestration _....__....-... - - ...._...._........- — —.._.. --- ...........................-- — -- — - Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone Sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load Procedure + Excursion" method. Cooliri '`S'sterri'Summary � s Cooling , Sensible/Latent 3 Sensible �� Latent Total . Btuh Btuh Net Required: 3.98 84% / 1'6% 40,044 7,725 47,769 Recommended: 4.45 75% / 26% 40,044 13,348 53,391 `A Eucn `ienfPata' Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh I I I i I I C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Basile.rh9 Friday, March 02, 2018, 1:20 PM Rhvac Residential & Ught Commercial HVAC Loads Elite Software Development, Inca Smith Heating Basile -� a 49:' System 4 Room Load Summary Htg, , Mms Run'�Run Clg +'� Clg Min Act. Room AKea Sens ' hHtg pact "� Duct Sgns Lat Clg gys No NameVet6K , Btuh ..Btuh r <, CFM . ---Zone 1--- 21 Office 237 2,222 29 1-9 480 4,662 200 212 212 22 Exercise 299 3,561 46 2-0 491 4,236 400 193 193 23 Vestibule 37 54 1 1-4 26 50 0 2 2 24 Bedroom 04 301 2,977 39 2-7 476 5,595 400 255 255 25 Bath 04 121 752 10 1-4 436 837 0 38 38 26 Hallway 114 799 10 1-4 346 664 0 30 30 27 Storage 02 68 427 6 1-4 159 305 0 14 14 28 Bath 05 ................... ---........................ _1 02 --- 1, 388. -----. �_$..-._..__ 1-4 590 1,132 -0-- 52 -- -- 52 -...._............. -- -- ' Zone 1 subtotal 1,279 12,180 58 17,481 1,000 795 795 ---Zone 2--- 35 Observation Deck _ 324 3,800 149 2-7 534 6,268 0 285 285 _ Zone 2 subtotal 324 $,800 149 6,268 0 285 285 Ventilation 0 _ 3,068 5,017 System 4 total _ _..... _ ._1,603 15,980 208 _ — _.. 24,068 _ 6,017 _ 955 _ 955 System 4 Main Trunk Size: 12x16 in. Velocity: 717 ft./min Loss per 100 ft.: 0.077 in.wg Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone Isensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load Procedure + Excursion method. ,Conlin 'S VtemtiSuummaA pf 63 nxei3�, #t '�, �.• •44 La N, r>ve t7n. Cooling Sensible/Latent :,� x"� `Senslble" Latent Total, 43, .Btuh b :.Btuh," Btuhr, Net Required: 2.51 80% / 20% 24,068 6,017 30,085 Recommended: 2.67 75% / 25% 24,068 8,023 32,091 Heating System Cooling System Type: Natural Gas F mace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh I I I i I II I I I I C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Basile.rh9 Friday, March 02, 2018, 1:20 PM r r tt iJ1 ` '",. ,+ a<'r S'++ N.+t :.v �N`;1 �:� �- r, a _ ''•. a, t to I 6v& L. D . f t � , NO -BURN® Plus XD, developed specifically for spray polyurethane foam (SPF) international code requirements as an intumescent latex based coating or ignition barrier alternate that acts as a shield, protecting the substrate from a flame source by surrounding the treated material with a protective char -barrier. Plus XD meets intumescent coating requirements over spray polyurethane foa T1. USES: 1 • Coverage rate 150-320 square feet per gallon , f • Water -based, non -toxic, non -carcinogenic intumescent paint -Applicable over open & closed cell spray polyurethane foam • Contributes to or meets green building standards t �� + FINISH/COLOR: � + �� x:�� � � � �, � • flat/white/tinted LOW VOC CONTENT & EMISSIONS: ) 18 /L I ! I fx c CDPH/EHLB/Standard Method Version 1.1, 2010 (Emission testing method for CA i Specification 01350) - m 4 CLEAN-UP: soap and water TESTED IN ACCORDANCE WITH. ICC-ES, NFPA 286/AC377 and Appendix X 4 Q _ EVALUATION REPORTS:' ' F� ICC-ES Reports, in accordance with AC377, may be found on the manufacturer's P Y website. r Material Film Thickness Spread t � Rat, o 6wet/ 4drymils 267sgftpergal Intertek No. 100645468SAT-001H' fz .� � BASF ENERTITE�N � � M Open Cell Spray Foam + Beyer BayseelTM OC 6 wet /4 dry mils 267 sgft per gal Intertek No 101266208SAT-002B Open Cell Spray Foam Convenience Touch n Seal® 7 75 pCloCell SpFoa: °, d •'r, f r + i'-- B wet/ 5 dry mils 200.sgft per gal ICC-ESR #3052 d sed ray m_ _ _� { }, • }f p;'>z 1�, }�'� Demllec SEALECT10AP500� Intertek No.100496956SAT-002D Open Cell Spray Foam 6 wet /4 dry mlls 267 sqft per gal ICC-ESR #1172 Demilec SEALECTION Agribalance°'- _^10 wet 16 dry mils 160 sgftpergal ICCESR#2600 Open Cell -Spray Foem -_ FOMO Handl Foam® E-84 10 wet] 6 dry mils 160 sgft per gal [CC-ESR #2717 Closed Cell Spray Foam Huberiw_s stem® ,RSheathing Panels 10 wet 16 dry mils 160, sgft per gal Intertek No 100936210SAT-002 + o lcyneyµ" Open a LD pray F' 6 wet 14 dry mils 267 sgft per gal ICC ESR #1826 ` Open Cell Spray Foam Icynene CDR 50 - i� , 10 wet h6 drymils. 160 sgft:per - ICC gal .ESR #2715 'u Open pell,Spray Foam Icynene MD-R-200 Open Can Spray Foam 5 wet / 3 dry mils 320 sgft per gal Intertek No 100648084SAT-008B QuadrarttUrethaOeTechnology QuadFoarn0500 " 8 wet J 5dry mils 200 sgft per g. F Intertek N0. 100514290sAT-002A " • " Service Partners SEAL PROnd 500 6 wet /4 dry mils 267 sgft per gal Intertek No. 100496956SAT-002D f ". - r , ,., °• °•, Open Cell Spray Foam ICC-ESR #2940 r -^ Servlce Partners"i am ROn" 800 - '+ _Open Cell Spray Foam ` 10wet /,6 dry mils - 160 sgft per gal ICC-ESR#3034 Tiger Foam Insulation E-84 Fire Rated SPF Clas10 wet 16 dry mils 160 sgft per gal [CC-ESR #3183 -r• tI . '+' ° ' s 1 Spray Foam t , ! a, ul: v AM No-Burn®'Plus XD ° Low VaC;.visibly white, water -based intu'mesGent coa4ng, supplied in 5-gallon (19 L) pails and 55.ga[Ion (20&L) drums. Sell Sheet International Building Code (IBC) I 2012 ' 2009 ' 2006 2003 i t Foam Elastics in Attics and Crawl Spaces International Residential Code (IRC) 2012 2009116 2 003. R316.5.3 (AC 377 Appendix X) R316.5.3 (AC 377 Appendix X) R314.5.3 (AC 377 Appendix X) R316.5.4 (AC 377 Appendix X) R316.5.4 (AC 377 Appendi x X) R314.5.4 (AC 377 Appendix X) 1 NFPA 286 with Acceptance Criteria (AC) 377 Appendix X- ICC ES Manufacturer certified installations available. All intended end -use applications, listed above, should be verified with the appropriate Authority or Authorities Having Jurisdiction prior to installation. 1 • e- a :oe .. Building Permit # Planning & Development Services Department Building & Regulations Division Product Review Affidavit 1712-0596 Owners Name Stephen & Lisa Basile Applicant: Foglia Contracting Corp. Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment Windows Casement +45.6 -60.9 100 -120 Windoor Series CA-9060 14-0305.03 Mullions +39.8 -49.2 93.4 -93.4 Windoor 2X6 Mull FL17137 Fixed Glass +45.6 -60.9 90 -90 Windoor Series 9020 Fix 12-0627.05 Block Glass Skylights ° Sliding Glass Doors +37.6 -44.9 50 -60 Windoor Series 8100 14-0107.14 Swing Type Doors +42.1 -54.0 70 -70 Windoor Series 9050 12-0627.07 Fold fienth Doors +38.0 -45.7 60 -65 Euro-wall Vista Fold FL17838 Garage Doors +32.1 -34.9 +45.8 -49.3 Amarr Garage Dnnrc 950 Heritage NOA 13-0503.08 Hurricane Protection Roof Ventilation Roofing Material RoofingAdhesive MR 23.44 Max MF 40.4 Entegra I 3M Corp lantation Med. Pad AH-160 Foam I dy 24g NOA 15-072 NOA 12-022 .04 .18 Roofing Underlayment -108.6 -112.5 Polyglass USA Polyglass E-7 NOA 17-1004.09 Revised 03/14/2018 I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: William P. Stoddard, Ph.D., P.E. Signature: seal ' Design Prof:. Professional Eng ineerCert. No. Date: 57605 3/14/2018 t Section E MIMI®Miami-Dade County HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area ,of the roof, then the tile attachment method is acceptable. 3:12 P 1; 108.1 X 0.289 = 3124 _ Mg; 7.79 = Mr1: 23.45 < 40.4 NOA Mf Med. Paddy 24gr. 7:12 P 2; 53_6 X 0.289 = 15 49 _ Mg; 7,04 _ _I = Mr2: 8 45 ; <_ 40.4 NOA Mf Med. Paddy 24gr. P3:xX= 1.;- Mg: =Mr3:<_ NOA Mf Method 3 "Uplift Based Tile Calculations Per RAS 127" For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. P1: XI:�= I Xw:=-W: P2X1:=Xw:=-W: P3 X1:= Xw:=-W: Where to Obtain Info X. cos 0: El = Fr1: < NOA F' _ XCos 0:El=Fr2: <_ NOA F' =11 XCos 0:=Fr3:<_NOA F' to complete tile calculations Description Symbol Where to Find Design Pressure P1 or P2 or P3 Table 1 RAS engineer based 127, or by an engineer analysis prepared, signed and sealed by a professional on ASCE 7. Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier X Product Approval (NOA) Restoring Moment due to Gravity Mg I Product Approval (NOA) Attachment Resistance Mf Product Approval (NOA) Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' Product Approval (NOA) Required Uplift Resistance Fr .Calcu d Average Tile Weight W Pro uct pprova ( A) Tile Dimensions I = length w =width Product Approval (NCA) ,I