HomeMy WebLinkAboutGENERAL DESCRIPTIONU tLIC00 Series TY-FRB, S.i Upright, Pendent, Quick Response, General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb -type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. SCA6ED Worldwide www.tyco4ire.com U Contacts St Lucia countV K-factor and Recessed Pendent Sprinklers Coverage o TYCO Series TY-FRB Sprinklers scribed herein must be installed :1 maintained in compliance with s document, as well as with the glicable standards of the National s Protection Association, in addition the standards of any other authori- s having jurisdiction. Failure to do so y impair the performance of these I owner is responsible for main - ling their fire protection system I devices in proper operating con- )n. Contact the installing contrac- or product manufacturer with any Sprinkler Identification I Number (SIN) 13.... Upright 5.61K, 1/2 in. NPT 23.... Pendent 5.61K, 1/2 in. NPT echnical Refer, efei to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 plsi (17.2 bar)* The Limum working pressure of 250 psi (17{1 only apQ lies to the listing by Underwriters Labo aF "fo ries, Incl (UL). Discharge Coefficient , K=5.6IGPM/psi''/2 (80,6 LPM/bary2) Temperature Rating Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated I Physical Characteristics Frame .1..........................Bronze Button.)....................Brass/Copper Sealing issembly ... Stainless Steel w/TEFLON Bulb...............................Glass Compres ion Screw.................Bronze Deflectors..........................Bronze >: -�.3 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Page 1 of 4 AUGUST 2018 TFP172 TFP172 Page 2 of 4 Components: * Temperature rating is ** Pipe thread. connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16" (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE -IN ESCUTCHEON 6* I 5 7/16" (11,1 mm) 4 NOMINAL 2" MAKE -IN (50,8 mm) 2 2" �\Q�I/ 1-3/8" 3 (50,8 mm) (34,9 mm) WRENCH / FLATS 1 1/2 NPT** DEFLECTOR * — 2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE i SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT, QUICK RESPONSE / WRENCH RECESS (USE ONLY END "A") FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS t PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb -type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135"F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak -tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N •m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over -tightening the sprinkler. Re -adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe -thread sealant applied to the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N•m). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe -thread sealant applied to the pipe threads, hand -tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N•m). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. 1". Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. TFP172 Page 3 of 4 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8" (15,9 mm) FLUSH 3/8±5/16" (9,5±7,9 mm) m) MOUNTING 1/8 SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 518 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4" 1/2" (12,7 mm) (7,9±6i4 mm) 1 FLUSH MOUNTING 1/8" 7_mr�_"��___��_ SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON imited /arranty warranty terms and conditions, visit w.tyco-fire.com. Irdering rocedure ntact your local distributor for avail- lity. When placing an order, indicate full product name and Part Number Sprinkler Assemblies with NPT TI)read Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP172 Page 4 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED POLYESTER 135°F(57°C) Orange UPRIGHT (TY313) 155°F (68°C) Red 175°F (79°C) Yellow and 1, 2, 3, 4, 5, 6 5.6 1/2 in. NPT PENDENT (TY323) 200°F(93°C) Green 286°F (141°C) Blue 135°F(57°C) Orange RECESSED PENDENT (TY323) Figures 4a and 5b 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) 6. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion -Resistant Sprinklers. a. Installed with Style 15 (1/2 in. NPT) 5/81n. Total Adjustment Recessed Escutcheon, as applicable. b. Installed with Style 20 (1/2 in. NPT) 1/2 In. Total Adjustment Recessed Escutcheon, as applicable. c. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A. LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/Na 77 — XXX — SIN 370 5.6K UPRIGHT (1/2 in.NPT) TY313 371 5.6K PENDENT (1/2 in.NPT) TY323 Notes: a. Use suffix "I" for ISO 7-1 connection; for example, 77-370-4-175-1 — XXX 71 SPRINKLER TEMPERATURE FINISH RATINGS 1 NATURAL BRASS 3 PURE WHITE (RAL9010)a POLYESTER 4 SIGNAL WHITE (RAL9003) POLYESTER 5 JET BLACK (RAL9005) POLYESTER 9 CHROME PLATED a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) 1400 Pennbrook Parkway, Lansdale, PA,194461 Telephone +1-215-362-0700 0201a Johnson Controls. All rights reserved. All specifications and other information shown were.,current as of document revision date and are subject to change without notice. Johnson IIn son NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON is a mgiatered trademark of OUPont tqC00 Series TY-FRB - Extended Cover Quick and Stane General Description TYCO Series TY-FRB 5.6 and 8.0 X-factor Extended Coverage Hori- zontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) are decorative 3 mm glass bulb type spray sprinklers designed for use in hydrau- lically calculated sprinkler systems in light hazard, commercial occupancies such as churches, restaurant seating areas, hotels, educational facilities, offices, etc. With their coverage up to 16 ft (4,9 m) wide by 24 ft (7,3 m) long, they are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Hori- zontal sidewall (HSW) sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desirable. The fast response thermal sensitivity rating of the Series TY-FRB, 3 mm bulb type sprinklers provides for a quick response extended coverage (QREC) rating for many of the coverage areas detailed in Tables B and C. The recessed version of the Series TY-FR8 Extended Coverage Horizontal Sidewall Sprinkler utilizes either a two- piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT), Recessed Escutch- eon with 1/2 in, (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush side - IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING' that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide I www.tyco4ire.com Contacts and 8.0 K-factor Horizontal Sidewall Sprinklers 'Response (Light Hazard) wall position, or a two-piece Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) Recessed Escutcheon with 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush sidewall position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe lengths to the sprinklers must be cut. orrosion resistant coatings, where pplicable, are utilized to extend the life f copper alloy sprinklers beyond that hich would otherwise be obtained hen exposed to corrosive atmo- pheres. Although corrosion resistant oated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is q�ot representative of all possible cor- rosive atmospheres. Consequently, i� is recommended that the end user be consulted with respect to the suit- apility of these coatings for any given corrosive environment. The effects of a bient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be T�e Series TY-FRB Sprinklers ddIIscribed herein must be installed an�� maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these an for owner is responsible, for main- 7g their fire protection system levices in proper operating con- 7. Contact the installing contrac- r product manufacturer with any Sprinkler Identification Numbers (SINs) TY3332... EC HSW, 5.6K, 1/2 in. NPT TY4332... EC HSW, 8.OK, 3/4 in. NPT Page 1 of 8 AUGUST 2018 TFP296 TFP296 Page 2 of 8 Compose is DEFLECTOR 4 2 - Button HAT ` I 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector* 1 \ 7 - Ejection Spring 6* 5 2 3 1 * Temperature rating is indicated on Deflector or adjacent to orifice WRENCH seat on Frame. 7 FLATS 1/2" ** / /NPT 'E 7/16" (11,1 mm) 1�II a_TT1 1-9/16" CENTERLINE 3 mm OF SPRINKLER 7/16"' ( ) WATERWAY (11,1 mm) NOMINAL MAKE -IN ** Pipe thread connections per 1-1/2" ISO 7-1 can be provided on (38,1 mm) special request. 7/16" 2-3/16" (11,1 mm) (55,6 mm) FIGURE 1 SERIES TY-FRB (TY3332) EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER 5.6 K-FACTOR, 1/2 INCH NPT Components DEFLECTOR 1 - Frame HAT ` 4 2 - Button I ' 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector* / 7 - Ejection Spring 6* 5 2 3 1 * Temperature rating is indicated on Deflector or adjacent to orifice WRENCH seat on Frame. 7 FLATS 3/4" ** (� NPT 7/16° 11,1 mm) 1-1/2° CENTERLINE OF SPRINKLER 1/2" (38,1 mm) WATERWAY (12,7 mm) NOMINAL MAKE -IN ** Pipe thread connections per 1-1/2" ISO 7-1 can be provided on (38,1 mm) special request. 9/16" 2-1/4" (14,3 mm) (57,2 mm) FIGURE 2 SERIES TY-FRB (TY4332) EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER 8.0 K-FACTOR, 314 INCH NPT Technical Data Approvals UL and C-UL Listed FM and NYC Approved (Refer to Table Afor complete approval infor- mation including corrosion resistant status, as well as the Design Criteria section per- taining to special design considerations.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K=5.6 gpm/psis/2 (80,6 Ipm/bars/2) K=8.0 gpm/psis/2 (115,2 Ipm/bars/2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table E. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button......................Brass/Copper Button......................Brass/Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw.................Bronze Deflector ......................... Copper Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria TYCO Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizon- tal Sidewall Sprinklers Quick and Stan- dard Response (Light Hazard) must be installed and utilized in- Light Hazard Occupancies, under smooth ceilings as outlined in the appliable installation standard recognized by the Approval Agency (e.g., UL recognizes NFPA 13, and FM recognize the FM Loss Preven- tion Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, is to be used for recessed installations. TFP296 Page 3 of 8 BULB SPRINKLER FINISHM K-FACTOR SPRINKLER TEMPERATURE LIQUID TYPE RATING COLOR NATURAL CHROME POLYESTER- BRASS PLATED I 135°F (57°C) Orange 5.6 1/2 in. HSW (TT Y3332) 1, 2, 3, 4 I 155°F (68°C) Red 175°F (79°C) Yellow NPT 135°F (57°C) Orange 1%2 n RECESSED EC HSWa 1, 2,4 155°F (68°C) Red NPT (TY3332) 175°F (79°C) Yellow 135°F (57°C) Orange 5.6 1/2 In. RECESSED EC HSWb 1, 2, 3, 4 1155°F (68°C) Red NPT (TY3332) 175°F (79°C) Yellow 1135°F (57°C) Orange 8.0 3/4 in. EC HSW TY4332) (T 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow NPT 1135°F(57°C) Orange 8.0 3/4 in. RECESSED EC HSWa 1, 2, 4 I155°F (68°C) Red NPT TY4332) I175°F (79°C) Yellow 1, 2, 3, 4 I135°F (57°C) Orange 8.0 3/4 in. RECESSED EC HSWb 1, 2, 3, 4 55°F (68°C) Red NPT (TY4332) 75°F (79°C) Yellow Notes: 1. Listed by Underwriters Laboratories, Inc. (UL) per Table C 2. Listed by Underwriters Laboratories, Inc. for use in Canada perTable C 3. Approved by Factory Mutual Research Corporation (FM) perTable D 4. Approved by the City of New York under MEA 354-01-E 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed corrosion -resistant sprinklers. a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3A in. Total Adjustment Recessed Escutcheon, as applicable b. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable c. Frame and deflector only I TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) SPRINKLER FINISH K-FACTOR SPRINKLER NATURAL CHROME POLYESTER TYPE BRASS PLATED EC HSW 5.6 (TY3332) 1/2 in. NPT 250 PSI (17,2 BAR) RECESSED EC HSW (TY3332) I OR 175 PSI (12,1 BAR) EC HSW 8.0 3/4 in. (TY4332) SEE NOTE 1 RECESSED EC HSW NPT (TY4332) Notes: 1. The maximum working pressure of 250 psi (17,2 bar) only appliel to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE B MAXIMUM WORKING PRESSURE TFP296 Page 4 of 8 5.6K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER (TY3332) Response Coveragge Minimum Minimum Deflector -to -Ceiling Sprinkler Minimum Rating Area( ), Flow(2), Pressure(2), Distance(3), Temperature Spacing(4), ft x ft (m x m) gpm (Ipm) psi (bar) Inches (mm) Rating, °F ft (m) Quick 16 x 16 (4,9 x 4,9) 26 (98) 21.6 (1,48) 4 to 12 (100 to 300) 135, 155, 175 10(3,1) Quick 16 x 18 (4,9 x 5,5) 29 (110) 26.8 (1,85) 4 to 12 (100 to 300) 135, 155, 175 10(3,1) Quick 16 x 20 (4.9 x 6,1) 32 (121) 32.7 (2,25) 4 to 6 (100 to 150) 135 10(3,1) Quick 16 x 22 (4,9 x 6,7) 35 (133) 39.1 (2,70) 4 to 6 (100 to 150) 135 10(3,1) Standard 16 x 20 (4,9 x 6,1) 32 (121) 32.7 (2,25) 4 to 6 (100 to 150) 155 10(3,1) Standard 16 x 22 (4,9 x 6,7) 35 (133) 39.1 (2,70) 4 to 6 (100 to 150) 155,175 10 (3,1) 8.OK EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER (TY4332) Response Coveragge Minimum Minimum Deflector -to -Ceiling Sprinkler Minimum Rating Areal ), Flow( ), Pressure(2), Distance(3), Temperature °F Spacing(4), ft x ft (m x m) gpm (Ipm) psi (bar) Inches (mm) Rating, ft (m) Quick 16 x 16 (4,9 x 4,9) 26 (98) 10.6 (0,73) 4 to 12 (100 to 300) 135, 155, 175 10 (3,1)/13 (4,0)(5) Quick 16 x 18 (4,9 x 5,5) 29 (110) 13.1 (0,90) 4 to 12 (100 to 300) 135, 155, 175 10 (3,1)/13 (4,0)(5) Quick 16 x 20 (4.9 x 6,1) 32 (121) 16.0 (1,10) 4 to 6 (100 to 150) 135 10 (3,1)/13 (4,0)(5) Quick 16 x 20 (4.9 x 6,1) 33 (125) 17.0 (1,17) 4 to 12 (100 to 300) 135 10 (3,1)/13 (4,0)(5) Quick 16 x 22 (4,9 x 6,7) 35 (133) 19.1 (1,32) 4 to 6 (100 to 150) 135 10 (3,1)/13 (4,0)(5) Quick 16 x 22 (4,9 x 6,7) 36 (136) 20.3 (1,59) 4 to 12 (100 to 300) 135 10 (3,1)/13 (4,0)(5) Quick 16 x 24 (4,9 x 7,3) 39 (148) 23.8 (1,64) 4 to 6 (100 to 150) 135 10 (3,1)/13 (4,0)(5) Quick 16 x 24 (4,9 x 7,3) 40 (151) 25.0 (1,72) 4 to 12 (100 to 300) 135 10 (3,1)/13 (4,0)(5) Standard 16 x 20 (4.9 x 6,1) 32 (121) 16.0 (1,10) 4 to 6 (100 to 150) 155 10 (3,1)/13 (4,0)(5) Standard 16 x 20 (4.9 x 6,1) 33 (125) 17.0 (1,17) 4 to 12 (100 to 300) 155 10 (3,1)/13 (4,0)(5) Standard 16 x 22 (4,9 x 6,7) 35 (133) 19.1 (1,32) 4 to 6 (100 to 150) 155,175 10 (3,1)/13 (4,0)(5) Standard 16 x 22 (4,9 x 6,7) 36 (136) 20.3 (1,59) 4 to 12 (100 to 300) 155,175 10 (3,1)/13 (4,0)(5) Standard 16 x 24 (4,9 x 7,3) 39 (148) 23.8 (1,64) 4 to 6 (100 to 150) 155,175 10 (3,1)/13 (4,0)(5) Standard 16 x 24 (4,9 x 7,3) 40 (151) 25.0 (1,72) 4 to 12 (100 to 300) 155,175 10 (3,1)/13 (4,0)(5) Notes: 1. Backwall (where sprinkler is located) by sidewall (length of throw) 2. Requirement is based on minimum flow in gpm from each sprinkler. The Indicted residual pressures are based on the nominal K-factor. 3. The centerline of the sprinkler waterway is located 7116 in. (11,1 mm) below the deflector (Ref. Figures 1 and 2). 4. Minimum spacing Is for lateral distance between sprinklers located along a single wall, otherwise adjacent sprinklers (i.e., sidewall sprinklers on an adjacent wall, on an oppo- site wall, or pendent sprinklers) must be located outside of the maximum listed protection area of the extended coverage sidewall sprinkler being utilized. 5. Minimum spacing is 13 ft (4,0 m) when design pressure exceeds 175 psi (12,1 bar), otherwise the minimum spacing is 10 ft (3 m). TABLE C UL AND C-UL LISTING COVERAGE AND FLOW RATE CRITERIA I TFP296 Page 5 of 8 5.6K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER (TY3332) Response Coverage Area(II), Minimum Flow( ), Minimum Pressure(2), Deflector -to -Ceiling Distance( ), Sprinkler Temperature Minimum Spacing(4), Rating ft x ft (m x m) gpm (Ipm) psi (bar) Inches (mm) Rating, °F ft (m) Quick 16 x 16 (4,9 x 4,9) 26 (98) 22 (1,51) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 18 (4,9 x 5,5) 30 (1II14) 29 (2,00) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 20 (4.9 x 6,1) 33 (1I25) 35 (2,41) 4 to 12 (100 to 300) 135,155 10(3,1) Standard 16 x 16 (4,9 x 4,9) 26 (9I8) 22 (1,51) 4 to 12 (100 to 300) 175 10(3,1) Standard 16 x 20 (4,9 x 6,1) 30 (1 j4) 29 (2,00) 4 to 12 (100 to 300) 175 10(3,1) Standard 16 x 22 (4,9 x 6,7) 33 (1?I5) 35 (2,41) 4 to 12 (100 to 300)) 175 10(3,1) 8.OK EXTENDED ((COVERAGE HORIZONTAL SIDEWALL SPRINKLER (TY4332) Response Coverage Minimum Minimum Deflector -to -Ceiling Sprinkler Minimum Rating Area(1), FIoW(2), Pressure(2), Distance(3), Temperature °F Spacing(4), ft x ft (m x m) gpm (lam) psi (bar) Inches (mm) Rating, ft (m) Quick 16 x 16 (4,9 x 4,9) 32 (12) 16 (1,10) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 18 (4,9 x 5,5) 36 (136I) 20 (1,38) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 20 (4.9 x 6,1) 40 (151) 25 (1,72) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 22 (4,9 x 6,7) 44 (167 30 (2,06) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 24 (4,9 x 6,7) 48 (182 36 (2,48) 4 to 12 (100 to 300) 135,155 10(3,1) Standard 16 x 16 (4,9 x 4,9) 32 (121) 16 (1,10) 4 to 12 (100 to 300)) 175 10(3,1) Standard 16 x 18 (4,9 x 5,5) 36 (136)I 20 (1,38) 4 to 12 (100 to 300) 175 10(3,1) Standard 16 x 20 (4.9 x 6,1) 40 (151) 25 (1,72) 4 to 12 (100 to 300)) 175 10(3,1) Standard 16 x 22 (4,9 x 6,7) 44 (167) 30 (2,06) 4 to 12 (100 to 300) 175 10(3,1) Standard 16 x 24 (4,9 x 6,7) 48 (182) 36 (2,48) 4 to 12 (100 to 300) 175 10(3,1) Notes: 1. Backwall (where sprinkler is located) by sidewall (length of th ow) 2. Requirement is based on maintaining both minimum flow and minimum residual pressure. 3. The centerline of the sprinkler waterway is located 7/16 In. (1j11 mm) below the deflector (Ref. Figures 1 and 2). 4. Minimum spacing is for lateral distance between sprinklers located along a single wall, otherwise adjacent sprinklers (i.e., sidewall sprinklers on an adjacent wall, on an oppo- site wall, or pendent sprinklers) must be located outside of the maximum listed protection area of the extended coverage sidewall sprinkler being utilized. TABLE D FM COVERAGE AND FLOW RATE CRITERIA TFP296 Page 6 of 8 WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation TYCO Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizon- tal Sidewall Sprinklers Quick and Stan- dard Response (Light Hazard) must be installed in accordance with this section. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm). A leak tight 112 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). A leak tight 3/4 in. NPT sprinkler joint should be obtained with a torque of 10 to 20 lb-ft (13,4 to 26,8 N•m). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under- or over -tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY FRB EC Sidewall Sprinkler The Series TY-FRB EC Sidewall Sprin- klers must be installed in accordance with the following instructions: Step 1. Horizontal sidewall sprinklers are to be installed with their center- line perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the deflector is to face towards the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figures 1 and 2, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. Series TY FRB Recessed EC Sidewall Sprinkler The Series TY-FRB Recessed EC Sidewall Sprinklers must be installed in accordance with the following instructions: Step 1. Horizontal sidewall sprinklers are to be installed with their center- line perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the deflector is to face towards the ceiling. Step 2. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1 or 2, the W Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step 4. After the wall has been installed or the finish coat has been applied, slide on the Style 10, 20, 30, or 40. Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the wall. Care and Maintenance TYCO Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizon- tal Sidewall Sprinklers Quick and Stan- dard Response (Light Hazard) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire pro- tection system that it controls, per- mission to shut down the affected fire protection system must be obtained from the proper authorities and all per- sonnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non -operation in the event of a fire or inadvertent oper- ation may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to Installa- tion Section.) Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. J MOUNTING SURFACE CLOSURE SERIES TY FRB EC 5/8±1/4" 15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING PLATE I/ 1/8" (3,2 }nm) 1-1/4" (31,8 mm) 3/4" (1g1,1 mm) 3/4" (19,1 mm) 1/4" (6, mm) FIGURE 5 SERIES TY-FRB RECESSED EC SPRINKLER ASSEMBLY WITH 7 314 INCH TOTAL ADJUSTI STYLE 10 RECESSED ESCUi 5.6 K-FACOTR, 112 INCH 5/8±1/4" (1 ,9±6,4 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING CLOSURE 2-7/8" DIA. SERIES (73,0 mm) TY-FRB EC 2-1/4" DIA. (57,2 mm) MOUNTING PLATE rmm 1/8" (3,2 m�) 1-1/4" (31,8 mm) 3/4" (19,1 mm) 3/4" (19,1 mm) 1/4" (6,41mm) FIGURE 7 SERIES TY-FRB RECESSED EC S SPRINKLER ASSEMBLY WITH TVI 314 INCH TOTAL ADJUSTMI STYLE 40 RECESSED ESCUTC 8.0 K-FACTOR, 314 INCH N TFP296 Page 7 of 8 1/2±1/8" (12,7±3,2 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING C*OSURE 2-7/8" DIA. (73,0 mm) SERIES TY-FRB EC1/4" DIA. 7,2 mm) MOUNTINGPLATE (3,2 mm) 1-1/4" (31,8 mm) 1/2" (12,7 mm) 1" (25,4 mm) 1/4" (6,4 mm) FIGURE 6 SERIES TY-FRB RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 INCH NPT 1/2±1/8" (12,7±3,2 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING 1(1111V CLOSURET7 2-7/8" DIA. SERIES (73,0 mm) TY-FRB EC 2-1/4" DIA. (57,2 mm) MOUNTING PLATE 11 II)I/,II I I 1/8" (3,2 mm) 1-1/4" (31,8 mm) 1/2" (12,7 mm) 1" (25,4 mm) 1/4" (6,4 mm) FIGURE 8 SERIES TY-FRB RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K FACTOR, 314 INCH NPT TFP296 Page 8 of 8 57 - XXX - X - XXX SPRINKLER FINISH 1 NATURAL BRASS TEMPERATURE SIN 3 PURE WHITE (RAL9010) RATING POLYESTER 135 135oF (57°C) 376 5.6K EC HSW TY3332 4 SIGNAL WHITE (RAL9003) 155 155°F (68°C) 396 8.OK EC HSW TY4332 POLYESTER 175 175°F(79°C) 5 JET BLACK (RAL9005) POLYESTER 9 1 CHROME PLATED TABLE E SERIES TY—FRB EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS PART NUMBER SELECTION Limited Warranty For warrany terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assembly with NPT Thread Connections Specify: Series TY-FRB, (specify SIN), Extended Coverage Horizontal Side - wall Sprinkler, K=(specify), (specify) temperature rating, (specify) finish, P/N (specify from Table E) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify`) finish, P/N (specify') Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 r� �J 1 0201SJohnson Controls. All rights reserved.All specifications and otherinformation shownwere current as of document revision date and are subjectto change without notice. Johnson - V0 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA we registered trademarks of National Fire Protection Association; Controls TEFLON Isa registered trademark of DuPont 1