Loading...
HomeMy WebLinkAboutPOOL SPECIFICATIONSFILE COPY PROPERTY LINE SAFETY BARRIER: PROVIDE 48" HIGH MIN. FENCE PER LOCAL CODE W/ SELF -CLOSING, SELF -LATCHING GATES (PRINCE DEV.) Ulm ►iL P.2) ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE DWELLING TO THE POOL SHALL BE EQUIPPED WITH AN EXIT ALARM TO COMPLY WITH THE FLORIDA BUILDING CODE CHAPTER 4, SECT. 424.2.17.1.9. R L3,f WE HAVE REVIEWED THE POOUSPA PLAN AND APPROVE ALL ELEVATIONS, DEPTHS, AND DIMENSIONS TO BE CORRECT UNLESS OTHER WISE NOTED ON PLAN. • APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6t" ED. SPECIFICAMNS MAX. WIDTH 12'-6" MAX. LENGTH 36' MIN. DEPTH 3'-6" MAX. DEPTH 5' SHAPE CUST ELEVATION T.B.D FILL FROM EXCAVATION: _ HAUL TILE: INCLUDED INTERIOR FINISH: GEM FINISH POOL PUMP: VS FHPM 17PIIA1 T WIiN ANSI/4PS194GCA59M1 PUMP MARE PER FBC / 1.20 DISCHARGE LINE TO GROUND JANDY "AQUA -PURE" 1400 SALT - INC HANDRAIL NA LADDER NA HEATER: NOTINCLUDED VACUUM HEAD INCL POLE UNCL VACUUM HOSE INCL BRUSH INCL LEAF SKIMMER INCL TEST KIT INCL TREE / STUMP REMOVAL NA _ REMOVE EXISITING CONCRETE__NA PUMP POOL PATIO NA SCREEN ENCLOSURE NA ELECTRICAL INC POOL PATIO PAVERS TO MATCH EXISTING PATIO NA DEC' (RAIN INC GALwN CAPACITY -POOL 13,838 GAL. TURN -OVER RATE 6 hrs TER—MITETREAT—IN—C BARRIER MAX. WATER VELOCITY - 6 ff.is FROM TRUNK LINES TO 8' SUCTION LINES, 10fps MAX RETURN LINE SKIIIN..OER MIN. FLOW 25 GPM SURFACE AREA OF POOL - 435 Sg. FT.97' GIAMUM NOT : . SEAMANS POOL CONBT.UCTON TO COMPLY WI FLA.. CODE AND W ALL LOCAL ORDINANCES AND IDNNOREGULATICNS. ].SINMMING PWL TO BEAR ON ROCK OR UNDISTURBED NANO, ALL WAIIB AND FLOORS ABDUL NE SHOUTED ORBOUIEOINPIACE CONCRETEM MIN IAMMI.OWPEI. CONCRETE It FS pAYN COAMEARRE STff.. S. ANDERSON SHALL BE NOTRED IF SOIL=I LINO LESS THAN NM PAY.. OR MUCK Sift -TOR LCOM SOFT SM N BOONS, A SOIL REAMS CAPACITY OF B 00 P,SFIN M . HAS BEEN USED EOC.. . FENFORS02 BARS SHALL BE HEW BILLET BRpDEb, CALLPOOL WNNOTOBEPH.C.SCHEDUIF W MIN. ANDBEARTHENA.F.APPRCIAL. S.BACKr...NALLMENCOFN ..LOCALONDINANCFS. '--S CSALOF POOL WATEp 811ALLCONFONMRILCC1LORpINANCE8.8V0ACE4MgHO5XNILONTAW WATER ENTEM PROPERTY TINES. SCREWS SHALL NOT PERNST FOR SORE THAN ONE HOUR, S. MATER VS CREMAL SHALL SE INSTALLED SO THAT THERE IS NO C ROSS CONNE THON WO!A DOMESTIC WATER SUPPLY M SISTER ACIMSLL SYBTEM. S. GRATE AT MPN GRAIN SHALL HAVE A MEE AREA OF FX THE AREA OF THE SUCTION TINE 1HAN ♦TNUMSTM MSHALLNAVEAREMCVABLESCIIEENWIAMNIMUMMEEAREAOFSXMEAREAOF THE... N LINE. " E L EC TRICAL: INSTALL MRINO A DEMOS AS SHOWN IN'POM DATA' HEREON. LIGHT CONNECTION TO CONFORM TONATYJNAL EIECTRICAL COOS LATEST NOTION, 1E. ALL METALLM CONCUITS, PIPING SYSTEdHR. RENFORCEO STEEL. LOST FIXTURES S MOUSING, NETAL FARTS OF IAODERR MANORNLS. SAME BOARDS& WPF RATS TO BE BONDED TOGETHER A tlbVNOEO TO A COMMON GROUND, BONRNO CONDUCTOR SHALL NOT BE SMALLER THAN H COPPER, 13 . NO OVERHEAD OPEN WIRE OMER PCOL BATIK CppTUWE FA ER SHALL HAVE A MTRATON RATE NOT TO EXCEEO S O.P.M. I S.F. OF ENRR AREA. NO BACK AASN REQUIRED. CIXITMACTOR SMALL VERB Y ALL OUSER M MR AND CON .N. AT SITE SNORE START.. THE P.CONTMCIOR SNA L VERRY LdT BB OF ELECT ECAL RENAME BY SF.PAI. CONRAN,, 10. SPECIAL ATTENTION SHALL BE OVER TO EXISTING FOURSA HON TO PRESENT UNOERMM UC. JOB NAME: BOWEN ADDRESS: 3911 DUNESIDE DR. LOT 24 TARPON FLATS PERMIT NO.: DATE DRAWN: MAY 7, 2018 DRAWN BY: F. DELROCCO DESIGNER APPROVAL: CUSTOMER APPROVAL: SCALE: 1/4" = 1' R ; CONCRETE 1 ROW OF WATERLINE TILE STEEL @ 12" O/C E.W. FLOOR SLOPEZ` FLOOR SLOPES SNALL Be REASONABLY UNIWRM AND C9MPLY Y11TH ARTICLES S A THRU E S.3 POOLS, INC. _ 6" THICK LIGH1 5' WALLS SHALL NOT 6" THICK SLOPE GREATER THAN 11E LHARD n;777 PE # 47041 1010 EASTER LILLY LN. FILE COPY P.1OF2 $CImivw mCft* W , LUCIE COUNTY BUILDING wFWED FOR COMPLIANCE PLANS ANU rcnl-1, I '_- -- SITE OR NO INSPECTIONS) WILL BE MADE ARE SUB ECT PLANS TO AN AND CO RECT ONSORI REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD FILE COPY RECEIVED MAY 2 3 2018 ST. Lucie County, Permlt0ng SCANNtD St Lucie CoMy COPING 4" MIN. LIGHT SP 10-22 WALL FITTING INSIDE PIPE POOL SAVI NICHELESS LED LIGHT NO NICHE 1" LIGHT CONDUIT UNDERWATER LIGHT DETAIL 1N' SCH 40 PVC (NoscaLE) SLEEVE EQUIFIVItIv 1 LATUU 1 LEGEND 1. 2" POOL RETURN LINE 2. 1.5" WATER SUPPLY TO DECK JETS 3. 2" VACUUM LINE 4. 2.5" POOL MAIN DRAIN LINE 5. 2" SKIMMER LINE A.VARIABLE SPEED FLOPRO REC. PUMP W/APPR HAIR & LINT STRAINER B. 1.5" TO WASTE OR TO GROUND C. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE D. VALVES (TYP) E. JANDY "AQUA -PURE" SALT SYSTEM CERTIFICATION OF COMPLIANCE Contents: 1 Part Number. Desulption: Size: 640-231X V p e w p • O �^^ r Round Anti -Vortex Suction outlet 8.1 Open Area: 11.83 i62 GPM @ 15 fps: 55 floorflow Bate: 100 GPM Wail Flaw flare: 64 GPM Date of Manufacture: LOA DEC 10 2000 This product has been tested to ANSI/ASME 112.19.8-2007 (addendum 8a-2008) per §1404 of the Virginia Graham Baker (VGB 2008) Pool and Spa Safety Act Certified by: Underwriters laboratories, Inc, 2929 E. Imperial Highway, Suite 100, Brea, CA92821-6729 This product Is certified to (amply with §1404 of the Virginia Graham Baker (VGB 2008) Pool and Spa Safety Act. A copy of the test results for the above may be found at www.waterwayplastics.com or go to www.ul.com,This product is manufactured by Waterway Plastics, Oxnard, CA 93030 Ganalna ti 2200 East Sturgis Road, Oxnard, (A 93030 • Ph. (805) 981.0262 • Eax 1805) 9BI-9403 u MAI.watervsypliBuG.mm•waterway@waterwayplastics.com C)tlam.,ftW 810-0150.1208 POOL RETURN LINES 2" TO FIRST TEE POOL DETAIL APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 • •• APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL WITH THE 2017 SUPPLEMENTS AND THE • • ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE MINIMUM -(2) SUCTION LINES PER PUMP 3_FT. SEPARATION OR SEPARATE PLANES • I 3 FT. MIN. 2.5" SUCTION LINE TO PUMP MAX 117 G.P.M. TO FILTRATION PUMP 6 FPS MAX 3" PLUMBING LINES FROM SUMP W/3" TEE SWIMOUTS_- WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE APPROVED WITH FBC 2017WATERLINE 20" max. 18" FILTRATION PUMP 345O WM _ 50 RP� FILTRA ION 1710 RPM I PUMP HIGH SPEED 0 10 20 30 W m 60 70 W 90 100 110 Im 130 IW ISO 16D 170 iW 190 2 FILTRATION I FLOW GPM PUMP LOW SPEED MISC,_NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT AREA WHERE DECK IMBED .6" ABOVE POOL #8 GROUND WIRE HANDRAIL BONDING DETAIL 12" MAX. WHERE APPLICABLE 48"MAX PER NATIONAL ELECTRICAL CODE WATER DEPTH F10" MIN. e o -STEP DETAIL 1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXC c IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 4000 P51. STEP DETAIL_ N.T.S. 0 SAFETY BARRIER: PROVIDE 48" HIGH MIN. FENCE PER LOCAL CODE W/ SELF -CLOSING, SELF -LATCHING GATES APPROVED DOOR/WINDOW ALARMS SAFETY BARRIER PER FRC 4501.17-4501.17.1.15 & ASTM5034-95, ASTM D3787-89, ASTM 653-96 & R4501.17.1 THRU R4501.17.3 POOL BARRIER PER FRC 4501.17-41.1.17.3 AND ANSI/NSPI-5-1995 FUTURE HEATER 30" MIN. CLEARANCE IN FRONT OF SUBPANEL Q11C ECG. --LAYOUT 1/a"=1 POOLBOND PB-2008 WATER W.L. DECK WIRE LOCATION OF WATER BOND EQUIPOTENTIAL BONDING GRID PER N.E.C. 2014 SEC. 680.26 (WHERE ADOPTED) 18" MIN. ( ENTIRE PERIMETER 7_ SOIL #8 SOLID COPPER BOND WIRE W/APPR. CLAMPS 8 GAUGE SOLID COPPER (ONE ON EACH SIDE WIRE OF POOL 4 TOTAL) __ EQ_UIPOTENTIAL.BONDING GRID DETAIL MINIMUM 18" (MAX. 24") FROM EDGE OF POOL AROUND PER N.E.C. 2014 SEC. 680.26 ENTIRE POOL PERIMETER (WHERE ADOPTED) BURIED 4" TO 6" DEEP • APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6t" ED. NOTE; CLEAN FILL COMPACTED TO 95% MAX. DRY DENSITY UNDER DECK ONLY NOTE: REMOVE GRATE 8 WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL 6"X6" TILE INTERIOR GRATE SHALL FINISH \. BE SECURED IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL PLUG GRAVELBED 6" TYP. FLOOR TO PUMP —► 60 AMP POOL PANEL WI(3) -#6 THHN CU WITHIN'/1' ELECTRICAL CONDUIT \ #8 SOLID CU GROUND WIRE TO EXISTING PANEL TYPICAL_W_ALL SECTII-ON_& WELL ALE)POINT (NO SCALE) ISTEEL-TEX FORM R KRAFT WALL #3 @ 12" O.C.B.W. (NOTE: FOR DEPTHS TREATER THAN V ADD 1- #3 COVE BAR @ 6" O.C. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2600 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. IS ASSUMED FOR THI` 'ESGN. S.P.S.T. TOGGLE SWITCH / MANUAL MOTOR SWITCH L/ VARIABLE SPEED FLOPRO PUMP MOTOR rW/BUILT-IN OVERLOAD SWITCH Wl3- #10 THHN CU WITH -IN Y:" CONDUIT TIMECLOCK DISCONNECT (2) POOL LIGHTS —J SALT SYSTEM (GFI NOT REQUIRED) 1. ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE. 2.3412 THHN CU WITHIN 1/2" MIN. CONDUIT FOR POOL LIGHT (S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER. 4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B) 5. PROVIDE W.P. G.F.I. OUTLET 10' MIN. - 20' MAX. FROM WATER'S EDGE ELECTRICAL DIAGRAM__ N.T.S. MUST HOLD 35 PSI FOR AT I FAST 10 MIN .: (NO SCALE) (2) MAIN DRAIN MIN. X APART r FILTER HAIR & LIN' CATCHER (COMPONENT OF PUMP I RAY REINHARD PE # 47041 1010 EASTER LILLY LN. VERO BEACH, FL. 32968 P. 2 OF 2 3 x-