Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & 2300�isirpiia Aven Certification for I Project Name: Seacoast Curb Adapters & Project Address: 2601 Industrial Avenue 3, Ft. Permit #: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and • Submit (2) copies for residential, (3) copies for coi o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a build o Any non-residential structure. * Note: Form not required for interior renovations pi certain minor building permits at the discretion of the welopment Services Department & Code Regulations Division Fort Pierce, FL 34982 — (772) 462-1553 Inc. DESIGN PARAMETERS AND ASSUMPTIONS USED: (c r. DESIGN CODE: Florida Building Code Fiftt . 2. Structure Designed as (check one): Enclose 3: Risk Category: _I II III IV 4._ Design Wind Velocity 160 mph 124 ASI 5. Mean Roof Height 19'-4" ft R 6. Components & Cladding Design Pressures Used: (P! Zone 1: 21.14 Zone 2: 21.14 Zone 3: 21.1i 7. Design Loads: Floor: NA PSF Roof/Dead: Dock: NA PSF Deck: NA PSF Stairs: NA 8. Were Shear Walls Considered For Structure? ` Load Compliance Florida Type: F-1 Construction Type: Type I I B :sled by the design professional of record. mercial with all permit applications involving the following: ig permit FILt COP ed that no exterior structural elements are affected and I building official. Contact the # above for questions. iplete all that apply) Edition with 20 14 Supplements using ASCE 7-10 Partially Enclosed Open Exposure Category: B * C D LRFD End Zone Width: 23 ft )f Pitch: 1/2 :12 Parapet: NA ft based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 4: 36.69 Zone 5: 36.69 Garage: PSF Roof/Live: Balcony: NA PSF PSF Fence: Na PSF Railings: 50 PSF es Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Yes I Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? . Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depictedIon these plans provide adequate resistance to the design forces specified: SignaQuire, Date, and Seal Revised 07/25/2014 Jeffrey D; Brasseur AR 17698 Print Name Cert # & Co. Cert Auth. Brasseu4 Drobot Architects, P.A. 224 Datulra St., Suite 311, West Palm Beach, Florida Company Name & Address