Loading...
HomeMy WebLinkAboutFORMBOARD- - _ RECENED q ' 0 i O RECED MAR 3 02010 U) 0 U of IL a 0 zd 0 0 FI G IL Lu IL n 3 0 LL Z w 7 FND 5/8" DIA. IRC (C. A. MITCHELL&ASSOC) N63'19'17"E 0,30' i I CONC. PARKING/DIVE AREA I LOT 11 (OCCUPIED —I INDUSTRIAL) I I I I EXISTING BUILDING F.F.E.=18.01 I .i GRAPHIC SCALE ( IN FEET ) 1 inch = 30 ft. t0 FND 5/8" DIA. IRC (C.A.MITCHELL&ASSOC) FND 5/8" DIA. IRC N05'47'08"W 0.24' FENCE (S,J.BROWN 4049) III nn$ 0.41N.` i N27'28'23"W 0.14' Nq o z I � I w I � p O O o O I rn LOT 14 O I z (BROADCAST STUDIO) � t D �I C7 I J ( —I I I S1 L11 dMs.. • � aFa'rn- yr 3 � tll h h �'�•x. pp////�� "(�%��Qt f rpt , t �' `{1' S z�,t 4�� s+ InJucOtal AvCd"' St 0 A t�t�wt� „ sty r a: r E I Rd 08([ast)_ 1:1 a08(Wescj ��.,� ,,;,,Tall PlneslMolatle Home Communrtp r Fortl Pierce _n) it M ,tnctzay Ave _. Le I:Oi �Glry C .� J�anila t;e ,Juanita Au NORTH FT. PIERCE ST. LUCIE COUNTY, FLORIDA �- NO SCALE St. L4o • Cc*FL. ��t��-ka TREE LEGEND Approved SIZES SHOWN ARE DIAMETER AT BREAST HEIGHT (DBH) SUBJECT FARCEL LEGAL DESCRIPTION �t2 OAK TREE 12" LOTS 12 AND 13, 3LOCK 7, AIRPORT INDUSTRIAL PARK UNIT ONE, ACCORDING TO CABBAGE PALM THE PLAT THEREOF RECORDED IN PLAT BOOK 12, PAGE 40, PUBLIC RECORDS OF ST. LUCIE COUNTY FLORIDA ,2. PINE TREE 12" ADDRESS: INDUSTRIAL AVENUE THREE FT. PIERCE, FLORIDA 34946 QUEEN PALM aet:�D 30 1©1B WI(aR LEGEND but" (P) PLAT DATA rk CENTERLINE C CALCULATED FROM FIELD MEASUREMENTS It PROPERTY LINE (D) DEED No. NUMBER DIA. DIAMETER TYP TYPICAL P.Q.B. POINT OF BEGINNING EL ELEVATION m P.L.S. PROFESSIONAL, LAND SURVEYOR CONC CONCRETE L.B. LICENSED BUSINESS CATV CABLE TELEVISION FIRM PERMANENT REFERENCE MONUMENT SQ. SQUARE SE CORNER d IRC 5/8" IRON RCID & CAP FT. FEET BLOCK 1 C.M. CONCRETE MONUMENT TOE TOE OF BANK (p)(C) O.R.B. OFFICIAL RECORDS BOOK TB TOP OF BANK PB .PLAT BOOK CHU OVERHEAD UTILITIES 33.82'(C) PG PAGE HDPE HIGH DENSITY POLYETHYLENE - 0 - CENTRAL ANGLE LS LIFT STATION WET R RADIUS WIP L ARC LENGTH IRON PIPE q BUILDING WALL LINE CB CHORD BEARING CD CHORD DISTAMCE CO-) WOOD POWER POLE UGE UNDERGROUND ELECTRIC FIRE HYDRANT DIA. CM &BRASS DISK UG AT&T UNDERGROUND AT&T VALVE 'ED "SLCVC BM PAUL" BM R/W RIGHT OF WAY 0 DRAINAGE MANHOLE (NAVD 88) RR RAIL ROAD SQ SANITARY MANHOLE CBS CONCRETE BLOCK STRUCTURE .142' © HAND HOLE WM WATER MAIN A/C AIR CONDITIONING SANITARY CLEAN OUT BLDG BUILDING WOOD POWER POLE H/C HANDY CAPPED CONCRETE POWER POLE F.F.E. FINISHED FLOOR ELEVATION —) GUY WIRE AND ANCHOR N.A.V.D. NORTH AMERICAN VERTICAL DATUM WELL N.G.V.D. NATIONAL GEODETIC VERTICAL DATUM C.R. COUNTY ROAE, CABLE TV JUNCTION BOX NSLRWCD NORTH ST. LUCIE RIVER WATER CONTROL DISTRICT SIGN a �, ASPHALT >$ INDICATOR LIGHT i Ei9f' ii�t ;v CONCRETE SCANNLU BY NOTES `ImleCnllntt 1) NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 2) ADDITIONS OF DELETIONS TO SURVEY MAPS OR REPORTS, BY OTHER THAN THE SIGNING SURVEYOR IS PROHIB TED, WITHOUT CONSENT OF THE SIGNING SURVEYOR. 3) THE LAST DATE 0-- FIELD WORK WAS MARCH 19, 2018. 4) LANDS SHOWN HEREON WERE NOT ABSTRACTED BY THIS OFFICE FOR RIGHT-OF-WAYS, RESERVATIONS, AGREEMENTS, AND/OR EASEMENTS OF RECORD. SUCH INFORMATION SHOULD BE OBTAINED AND CONFIRMED BY OTHERS THROUGH APPROPRIATE TITLE VERIFICATION. 5) UNDERGROUND UTLITIES, UTILITY SERVICES, FOUNDATIONS AND IMPROVEMENTS WERE NOT LOCATED AS A PART OF THIS SURVEY. 6) TO MAKE THE MAP LEGIBLE THE SYMBOLS SHOWN HEREON AND AS DESCRIBED IN THE LEGEND ARE NOT ALWAYS TO SCALE, BUT INDICATE THE SURVEYED LOCATION. 7) DESCRIBED PROPERTY IS LOCATED WITHIN AN AREA HAVING A FLOOD DESIGNATION "X", BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA), ON FLOOD INSURANCE RATE MAP NO. 12111CO155J, (PANEL NOT PRINTED) IN ST. LUCIE COUNTY, FLORIDA. 8) ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88) AND REFERENCE BENCHMARK "PAUL", HAVING AN ELEVATION OF 14.142 FEET. TO CONVERT ELEVATIONS FROM NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88) TO NATIONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD 29), ADD 1.48 FEET. 9) SUBJECT PROPERTY CONTAINS 2.500 ACRES, MORE OR LESS (108,900 SQUARE FEET). 10) THE NORTH LINE OF INDUSTRIAL AVENUE THREE IS ASSUMED TO BEAR N89'49'02"W AND ALL OTHER BEARINGS SHOWN ARE RELATIVE THERETO. UNLESS OTHERWISE NOTED, ALL BEARINGS AND DISTANCES SHOWN ARE PER RECORD PLAT (P) AND CALCULATED (C). 11) THE EXPECTED USE IS COMMERCIAL. BOUNDARY ACCURACY EXCEEDS 1:10,000. 12) ALL MEASUREMENTS SHOWN ARE BASED ON AND IN ACCORDANCE WITH U.S. STANDARDS AND ARE IN FEET AND DECIMALS THEREOF. 9 �-n MICHAEL T. OWEN DATE PROFESSIONAL SURVEYOR AND MAPPER FLORIDA REGISTRATION #5556 EQC PFOvI # 16-282 �. I�r � ENGINEERS ® SURVEYORS PORT SAINT LUCIE 10250 NW VILLAGE PKWY. PORT SAINT LUCIE, FL 34987 e 772-340-4990 '0 www.edc-inc.com F.B.P.E. CERTIFICATE OF AUTHORIZATION 993 L.B. CERTIFICATE OF AUTHORIZATION 8098 �yml m W F �mJ1 Y O m Z W O Q O NI �� 0 cb 0 a MICHAEL T. OWEN PSM #5556 T PORT SAINT LUCIE 10250 NW VILLAGE PKWY. PORT SAINT LUCIE, FL 34987 9M� 772-340-4990 —1 1 OF 1