HVAC CONVERSION PLAN PAGE 31-45
f ENLARGED EXISTING D 1 /411 = 11-01, B -- q ENLARGED EXIS' 1 /4" = 11-01, e SB SB N :TRICAL ROO' ELECTRICAL EXISTING 480V, 3-SECTION SWITCHBOARD SE ,- EXISTING 480V, '4, 1-SECTION SWITCHBOARD MDP F EXISTING 480V PANEL HH1 r- EXISTING 480V PANEL HH2 SB c l ELEC. m 151 3 ND FLOOR T MEZZANINE EXISTING 480V PANEL HH3 XISTING 480V/208V RANSFORMER'TO" XISTING FARADAY MPC-6000 IRE ALARM CONTROL PANEL XISTING 208V PANEL 1C"(D XISTING 208V PANEL "LBO" 20 EXISTING COMMUNICATIONS EQUIPMENT LOCATED HERE 4.4) EXISTING 480VPANEL HL1 EXISTING 480V PANEL HL2 EXISTING 480V PANEL HE r-EXISTING 208V PANEL LBR EXISTING 208V PANEL LRR1 EXISTING 208V PANEL LRR2 EXISTING 480V1208V TRANSFORMER'TR" GENERAL NOTES 1. REFERENCE THE SYMBOL LEGEND AND GENERAL NOTES ON SHEET E001. 2 REFERENCE THE RISER DIAGRAMS ON SHEET E601. 3. REFERENCE THE ELECTRICAL SCHEDULES ON THE E700 DRAWING SERIES. 4. REFERENCE THE ELECTRICAL SPECIFICATIONS ON THE E800 DRAWINGS SERIES. REFERENCE NOTES iO EXISTING GENERAL ELECTRIC, PANEL "LC" WITH 100 A MAIN BREAKER, 208/120 V, 3-PHASE, 4-WIRE, 10,000 AIC AT 240 V PANELBOARD TYPE CCB. PROVIDE A NEW 15A/1-POLE BREAKER IN EXISTING SPACE LOCATED AT CIRCUIT # 32 TO SERVE NEW EXHAUST FAN EF-4. 2O EXISTING GENERAL ELECTRIC, PANEL "LBO" WITH 125 A MAIN BREAKER, 208/120 V, 3-PHASE, 4-WIRE, 10,000 AIC AT 240 V PANELBOARD TYPE CCB SERVING EQUIPMENT AT THE MEZZANINE LEVEL. 3O NEW FEEDER FROM EXISTING PANEL HH1. SEE SHEET E201 FOR REQUIREMENTS AND CONTINUATION. Sims Wilkerson Cartier Engineering, Inc. 12124 High Tech Avenue - Suite. 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-5900 FL. CERT. OF AUTH. NO. 6106 o Ci,LL Y A. µ'0 KH60N, P.L. 41167 o M IS J C AR I'IBR, RR. 51M, o kDkMS LLAIAI P.L.77010 n.TJ?JT 4 FL2IN11v PE. h 6n •9A\R ILR VI ISA]DI'R PE. cyp> 14001 _A1F����i,/i O, STATE OF 441 4v /01VlA— :,. LI I I I I I- J Q U_ H U LLJ U f6 Lr) w C/) 0) O O Oz J LL O C7 +�+ = =) CD O > O F— ww U U 0 0 a) U w J J w U) = cn O to ILLo N � W O V ^ _ o ■ i LUMINAIRE TYPE SU (TYPICALOF 2) CHILLER PLA 1 /4" = 11_011 M ECTION 1 - HILLER PLANT SECTION 2 - ELECTRICAL 1 /4" = 11-011 Sims Wilkerson Cartier Engineering, Inc. 12124 High Tech Avenue - Suite. 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-5900 FL. CERT. OF AUTH. NO. 6106 OG, 1y A. M PIRSM, P.2. 43167 0 6'YI F J. C,=p, PL 53169 o AUAM S. INv6C P L 771)111 In 1-y A. KMKl 4N. IT 65639 • S %NULL 2. A LC4Nll8R BP_55f22 14001 IR'IAL�/v///// •. STA'IIt�O Il\0\\\\ 11 _J Q U (6 L N O N U J c LL o w �J c .o ' o > o F— U) U C U O ~ U W U J Q J a Ui cf) cn = cn O LL o N 0 p W p 0 N U) CV w 5/8"x10' GROUND POLE TOP LUMINAIRE, BOND TO LUMINAIRE AND EQUIPMENT GROUNDING CONDUCTOR. LUMINAIRE SL1 POLE DETAIL SCALE: NOT TO SCALE 6"SQUARE CONCRETE POLE, TYPICAL STAINLESS STEEL —` 1.1/2"xl-1/2" METAL CHANNEL SUPPORT BOLTED TO CONCRETE POLE AS REQUIRED FOR EQUIPMENT AND CONDUIT SUPPORT, TYPICAL. =AND REPLACE CONCRETE OR 4ROUND NEW JECESSARY FOR WEATHERPROOF GFCI PION OF NEW POLE DUPLEX RECEPTACLE CONCRETEPAD BY DIVISION 15 ATED— I CONCRETE, TYPICAL: CHILLER CIRCUIT BREAKER ENCLOSURE, TYPICAL CB/CH-1 CB/CH-2 CONDUIT, TYPICAL CB/CH-3 (FUTURE) ---------- L77 Y7 II 11 s SIZE OF RACK TO BE AS REQUIRED FOR EQUIPMENT SIZES. MINIMUM 12" SPACING BETWEEN CIRCUIT BREAKER ENCLOSURES, 6" SQUARE NEMA 4X WIREWAY KINDORF PIPE STRAP, SIZE AS REQUIRED, TYPICAL. IIIMIN 24" 4" GENERAL NOTE' SEE NEW CHILLER PLANT ELECTRICAL RISER DIAGRAM ON SHEET E601 FOR OTHER UUIPMENT REQUIREMENTS. CHILLER CIRCUIT BREAKER RACK MOUNTED DETAIL NU I O SUALL [:111 Sims Wilkerson Cartie Engineering, Inc. 12124 High Tech Avenue - Suite. 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-5900 FL. CERT. OF AUTH. NO.6106 o GARY A. ANU�RSON, PE. 43167 o RYLE J. CARi➢: P.E. 53269 oAD S." WE, F.E. 77010 o XE A &IlUf N, RE, 65629 d SA TL R AIEXAN EP, P.E. 55 M 14001 �'oIR'IAL. �\�•��GENs -A `, ST '-51 40RIDP•G�2��: NIAI _1 U C) O � O O � J U ( C: d' J W o W Q IL � J W fr_ Q ♦; U) o LL O CV O W O f\ p `T rC/) v / - �IU GRADE GRADE EXISTING FPL 1,500kVA TRANSFORMER (# 6-6372-4929) WITH 13.2kV PRI/480V SEC, AND 28,682A OF AVAILABLE FAULT CURRENT OUTSIDE i EXISTING 2,000A, 480V, 3-PH, 4-WIRE, SQUARE D GROUND -FAULT PROTECTED ENCLOSED CIRCUIT BREAKER RATED 65kAIC @ 480V kWH METER MDP1 NEW UTILITY FUTURE TRANSFOMER, CB/CH-3 UT-1 13.2kV PRI/480V SEC WITH 1,800A ESTIMATED AVAILABLE FAULT CURRENT IS 18,000A METER SWITCHBOARD SE PANEL HL XFMR 'TR' PANEL HE PANEL HH SWITCHBOARD MDP O2 PANEL HMB REFRIG PANEL HH3 EXIST. SE 350 kcmil IN YC. OUTSIDE 1 E501 C80-2 C130-1 O O L STORAGE149 SPD 17MDP2 CPH i I I i T-CPL1 GENERAL NOTES 1. REFERENCE THE LEGEND AND GENERAL NOTES ON SHEET E001. 2. REFERENCE THE ELECTRICAL SCHEDULES ON THE E700 SERIES SHEETS. 3. REFERENCE THE SPECIFICATIONS ON THE E800 SERIES SHEETS. 4. EQUIPMENT ON EXISTING ELECTRICAL RISER DIAGRAM ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. 5. REFERENCE THE OVERALL GROUNDING DIAGRAM FOR THE NEW PANELBOARD MDP2 ON SHEET E602. 6. PROVIDE STAINLESS STEEL ENCLOSURE AND SUPPORT FOR ALL EXTERIOR EQUIPMENT. 7. UTILITY TRANSFORMER, UT -I IS APPROXIMATELY 200 FEET AWAY FROM CHILLER CIRCUIT BREAKER RACK. CPHI WAREHOUSE205 CPL2 REFERENCE NOTES O EXISTING GENERAL ELECTRIC, 1600A, 480/277V, 3-PHASE, 4- WIRE, 65,000 AIC AT 480V, THREE SECTION FUSIBLE SWITCHBOARD, TYPE AV -LINE. THIS EQUIPMENT WAS PART OF THE ORIGINAL ELECTRIC DISTRIBUTION INSTALLATION, AND IS NOW APPEARS TO BE RE -FED FROM SWITCHBOARD MOP WHICH WAS ADDED LATER. 2O EXISTING SQUARE D, 2000A 480/277V, 3-PHASE, 4-WIRE, 100,000 AIC AT 48OV, SINGLE SECTION FUSIBLE SWITCHBOARD, TYPE QED. THIS SWITCHBOARD WAS ADDED AFTER THE ORIGINAL ELECTRIC DISTRIBUTION INSTALLATION. Q EXISTING GENERAL ELECTRIC, 800A 480/277V, 3-PHASE, 4- WIRE, 14,000 AIC AT 480V PANELBOARD TYPE CCB. REMOVE ALL CIRCUITRY, EXCEPT CIRCUIT BREAKERS FROM THIS PANEL BACK TO THE AHUs THAT ARE TO BE DEMOLISHED UNDER THIS CONTRACT. ® THE EXISTING COMPARTMENT COVER JUST ABOVE THE MAIN CIRCUIT BREAKER COMPARTMENT HAS A BURNT OUT HOLE APPROXIMATELY 3" BY 2". THIS IMPLIES THAT THERE WAS SOME SORT OF ARCING INCIDENT WITHIN CIRCUIT BREAKER ENCLOSURE. VERIFY THAT THE CIRCUIT BREAKER, AND THE INSULATION OF THE CONDUCTORS CONNECTED TO IT ARE SUITABLE FOR CONTINUED SERVICE TO THE EXISTING FACILITY. O NEW FEEDER TO NEW HVAC PANELS, SEE SHEET E201 FOR LOCATION AND REQUIREMENTS. © PROVIDE SURGE SUPPRESSION DEVICE WITH INTEGRAL FUSED DISCONNECT (NEMN3R). PROVIDE DOUBLE LUGS ON LOAD SIDE OF CIRCUIT BREAKER TO FACILITATE SPD CONNECTION. O7 SERVICE ENTRANCE RATED EQUIPMENT WITH A MINIMUM OF 2/0 AWG CU MAIN BONDING JUMPER. PROVIDE A 3/0 AWG CU COMMON GROUNDING ELECTRODE CONDUCTOR (CGEC) FOR CB/CH-1 AND CB-CH-2. CONNECT TO THE CGEC WITH TAPS FROM CB/CH-1 AND CB/CH-2 SIZED AT 2/0 AWG CU. CONNECT THE CGEC TO (3) 3/4"x2O' GROUND RODS EQUALLY SPACED. ALL CONNECTIONS ARE TO BE EXOTHERMIC WELD. ® (2) 3" CONDUIT FROM UTILITY TRANSFORMER SECONDARY OPENING IN TRANSFORMER SUPPORT SLAB TO BELOW EQUIPMENT FUTURE LOCATION AT RACK SUPPORT. CAP AND LABEL CONDUITS FOR FUTURE USE. i O CUT AND PATCH THE EXISTING CONCRETE AND ASPHALT SURFACES AS NECESSARY FOR THE INSTALLATION OF THE i UNDERGROUND CONDUITS. NEW CHILLER PLANT ELECTRICAL RISER DIAGRAM 01 NOT TO SCALE MAIN ELECTRICAL ROOM _ MEZZANINE OPEN AREA STORAGE AUTOMOTIVE i (3)#41N 1-1/2"C. �(4)#310IN2-1/2"C, (3) #1 /0 IN 2"C. (4)#1IN1.112"C. LTG PANELHL CONTACTORS PANEL PANEL PANEL PANEL HH1 HH2 HL1 HL2 PANEL HH PNL LRR SQ.D PNL PNL HE PNLLBR G.E. G.E. XFMR'TR' 110AMCB 800A MLO 600A MLO G.E.225kVA 208V LRR2 480V,3-PH 2O8V,3-PH 4BODELTA1277V 3-PH 25 kAIC @ 22 kAIC @ TO PNL LRR1 S25A Q. Q. D D 2225A 480V 240V 208Y/120V, 2.9%Z%Z 3-PH `T 7 T (2) 3-1/2"C. (2) 3-112"C. W/ (4) WI (4) 500 350 kcmil IN EA. C. kcmil IN EA, C. (2)1-112"C. W/ (3)1/0 AWG IN EA. C. (2) 3"C. W/ (4) 350 kcmil IN EA. C. EXISTING ELECTRICAL RISER DIAGRAM NOT TO SCALE PNL HH3 E SQ.D PANEL 480A MLO LBO 380V,3-PH 35 kAIC @ 480V PANEL LC (4) #3 IN 1-1 (4) #31N 1-1/2"C. XFMR XFMR 'TF 1 'TI' (3)#81N 1"C. (4) #410 IN 2-1 /2"G. NEW NEW PANEL PANEL PANEL PANEL PANEL LBF HH4 HH5 LT HT XFMR 751KVA Sims Wilkerson Cart Engineering, Inc. 12124 High Tech Avenue - Suite. 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-5900 171 CERT. OF AUTH. NO. 6106 o GA Y.4. MXMRSGN.. P.E. 43167 o ai4.e J. CARII t RE 53269 oA W S. UV9NE, P. E. 77010 o MTF.4. KptA3L4\. PE. 65629 •SAMLF3. R.UE\.iV EK PE. 354M 14001 U (U LO N N_ ¢ O 0 J c LL 0 co �+ �• IV' c c I )W^ 0 > 0 F- U o C.) C) W W 0 m (1) 2 (n 0 LO LL E 0 W M W TO UTILITY TRANSFORMER, UT-1 (TO PANEL MDP-2) B ? N PANELBOARD MDP2 SUPPLY FEEDER (PANELBOARD CPH1 SUPPLY FEEDER) #3/0 AWG CU GROUNDING ELECTRODE CONDUCTOR AVAILABLE ELECTRICAL CONTINUOUS METAL WATER PIPE ELECTRODE IN DIRECT CONTACT WITH AT LEAST 10' OF EARTH MINA AWG CU GROUNDING ELECTRODE CONDUCTOR AVAILABLE 20' CONCRETE ENCASED ELECTRODES OF 1/2" DIA RODS OR 4 AWG CU NEW PANELBOARD MDP2 (PANEL CPH1) 4 —A 8 C r �2 NEUTRAL BUS GROUND BUS G N TO OTHER MDP2 (CPH1) LOADS AS INDICATED MIN. 2 AWG CU TO CLOSEST LIGHTNING GROUND TERMINAL AVAILABLE EXISTING LIGHTNING PROTECTION GROUND TERMINAL 3/0 AWG CU GIRD ELEC CNDTR G C B A TYPICAL OF (3) 3/4"X 10- — COPPERWELD GROUND ROD ELECTRODES SPACED 10' APART A B C G Z� NEW POWER GROUNDING DIAGRAM E602 j NOT TO SCALE 480/208 V TRANSFORMER T-CPL1 (T-CPL2) 3/0 AWG CU GIRD ELEC CNDTR (TYPICAL OR 3) 208 V PANEL CPL1 11 NEUTRALBUS 6 G-7 GND BUS G N GENERALNOTES 1. REFERENCE THE ONELINE DRAWING ON SHEET E601. 2. REFERENCE THE ELECTRICAL SPECIFICATIONS ON THE E800 DRAWINGS SERIES. 3. GROUNDING DIAGRAM SCHEMATIC IS FOR BOTH PANEL MDP2 AND PANEL CPH1 WITH CPH1 EQUIPMENT INDICATED WITH PARANTHESES WITH EXCEPTIONS NOTED.. TO OTHER CIRCUIT BREAKERS IN PANEL )---(D B C TO TYPICAL PANELBOARD LOADS GROUNDING DIAGRAM REFERENCE NOTES: O1 SUPPLY SIDE BONDING JUMPER. PROVIDE 310 AWG COPPER. O SWITCHBOARD OR PANELBOARD TYPICAL FEEDER OR BRANCH CIRCUIT BREAKER. O MAIN BONDING JUMPER. PROVIDE A MINIMUM 310 AWG COPPER OR EQUIVALENT BUS 4O SWITCHBOARD MDP2 OR PANELBOARD CPL1 MAIN CIRCUIT BREAKER. O MANUFACTURE CONNECTION BETWEEN EXTERNAL NEUTRAL BUS AND INTERNAL NEUTRAL POINT OF THREE PHASE WINDING, O SYSTEM BONDING JUMPER. PROVIDE #6 AWG COPPER. O SUPPLY SIDE BONDING JUMPER. PROVIDE #6 AWG COPPER. O GROUNDING ELECTRODE TAP CONDUCTOR. PROVIDE #3/0 AWG COPPER. THIS CONNECTION IS MADE ONLY FROM MDP2 TO CPL1, AND FROM MDP2 TO CPL2. THIS CONNECTION IS NOT MADE FROM CPH1 TO CPL2, NEITHER FROM CPHi TO CPL1. O DO NOT BOND NEUTRAL AND GROUND BUSES FOR PANEL CPH1. DO NOT PROVIDE GROUNDING ELECTRODE CONNECTIONS TO PANEL CPH1. Sims Wilkerson Cartie Engineering, Inc. 12124 High Tech Avenue - Suite. 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-5900 FL. CERT. OF AUTH. NO. 6106 o GARY A WILL:ERSON, PE. 43167 o K U 1. C.RT P.E. 53M9 o ADA S.UN1, P.E. 7010 oZH A. ISRIi1W1N, P.E, 6562 • SX�MEL R. ALEXA M PE. 554V 14001 9 w O LL w D U) VJ G (D �C) V Z CD cr. w O w Z 91 T U (u N •� J � ILL >, O ' >; � C � L � � O > O U o U U J Q J Cn +� (n 2 L0 00 o M � 04 C:) r C.0 w J EQUIPMENT FEEDER SCHEDULE DATE: COND 5 JOB NUMBER 14001 EQUIPMENT LOCATION VOLT$ PH NEUT MOTOR ADDITIONAL HEATER CR MISC TOT At. S(:kIRCE PNL DISCONNECT SVATCH STARTER :VOLTAGE WIRE NEUT GhID # CONDUIT NOTES DESCRIPTION Y (E-ARGEST"I MOTORS LIGHTINGLi1AD AMPS AMPS &ANELIGB G;& NAME SS2E FU8E SITE TYPE DROP PER SIRE N#RE OF SIZE OR H.P. FLA H R FLA KW AMPS SIZE AMPS $1ZE NEA4A PHASE RUNS N AA4PS AMPS VAV4-01 WAREHOUSE 205 AREA B 480 3 N �� 240 ;°. % HW4 40 `f29",G #8 ` #'10 1 31r VAV 3-42'. C FEN. COLOR AREA'S #80 .3 N " y,,, -- -"„ �,. 8 4 ; rl" _ T ., , € , HH4 16 12S°ta # 12 # 12 1 112" I VAV 4.03 GREEN COLOR AREA S 480", 3 N _. _ 6 0 /i�„2 �, �/i � HH4 15 143°,4 R12 #12 1 1(2" _ VAV 4-04 GREEN COLOR AREA % 480 3 N HH4 i5 095% P 12 # 12 1 1f2°: '�,"AV4"04,6.05,&4b',3Stls).... xJAfUEFa '27P 2 Y r.... _ s 1:{1 :� HH4 U:4d3a #12 #12 #72 : 1 1f2" ._._.-.,.., �ii" HH4 15 157% #12 #12 #12 1 112" VAV Fw01 N'11. HANDS CLINIC AREAA 2AT # Y „� 3.0'�, VAV "2 DENTAL&HANDSGLINICAREAA 277 1 Y -- ��-`:' 213 �l< HH4 15 1,05% =12 #t2 #12 _1 112 r�i #t2 1 112 VAV�43 DEN TAL&HAND$CLINICAREAA 480 3 N 50 HH4 15 0f5el% kit VAV&04 DEN"T,AL& HANDS CLINIC AREAA 277` 1 Y �. 7 :� -' � __V -._ ,% HH4 15 43°1<, #12 i #12 1 1i2 ', ' ¢BY4 15 012% #12 � :< #1'2 1 112 VAV&-06 DENTAL &HAN€JS-Ci INICAREA ,A 277 1 Y �_ _ _ _._ ( _ _l w- HH4 15 147% #1J #2 1 i12" VAV 7-01 VAV7.02 DENTAL &HAId CLINIC AREA A DENTAL& HANDS' CLINIC AREAA 277 "2r�' 1 1 Y Y ._. //i(�, HH4 HH4 15 15 t5 i 0.62% 012 # 12 #12 #12 1 f 1i2' 112" VAV7.03 DENTAL&HANDS CLINIC MEAA 277 1 t `-�•5 H144 15 107% #12 112 1 VAV7.04 DENTAL &HANDS INICAREA.A 277 A .Y ,: •1 _ HH4 &5 i Qir7"k #12 r #1� T 1t2" VAV,'-;35 OfNTAL&14AANDSCLINIC AREAA 277- '1 Y - i � _._ HH4 15 0.78% # 1 .. #12: 1 112" VAV f,4..1:,1 CLINIC AREAA 480 $ N i ,, :- vA', _ I ( HH4 15 i39% #' 6 #12 1 1i2" CLtN1C AREA AT7 1: Y 15 048% #12 #12,V8-04 9-03 CLINIC AREAA 480 3 N �I glA"1_02 CLINIICAREAA CLINIC AREAA 480 277 3 1 N V..:" ._...._ _ ; ' 3 , IHH4 HH4 .. _-....V&05 NH4 1& t5. 0,46% : 215°la #12 #1212 #12 #12 1 1 112".... td2"V&06 t1H4 115 0,57% #12 #I1'2 #12 1 112V CLINICARFAA 277 1 Y _I 1 8-07 VAVSU9= CLINIG AREA A CLINIC AR FAA 480 46Q 3 3 N - a HH5 15 e IAH5 t 15 < - 115 9 ,,,., I c _ ..-, - 47 ,� 5.0 -t 20 ". - - ; E;, H - I 50 �. _ 51? �' S`% EX LRR 20 _ I_ ° ., biHS 1b 029% 036% # 12 #12 412 #12 1 tf2" 112" 0.29410 #12 #12 1 112" VAVS49 CLINIC AREAA 480 3 N 1,1 J"k #12 #12 ! 112" VAV & 10 CLINIC P,IREA,A 480 3 -_ N r " 014°I" pi% #8 #12 912 # 1Q #12 '1 1 3t4" 112' (C) AHU-1 Condemm, PUtnpCPIAHU-1 AF#U-2 _ C¢rndAns Purrpi 4AHU-2 AHU-3 NEXT TO MAIN ELEC RM NEXT TO MAIN ELEC RM NEXT TO MAIN ELEC kT#4 :NEXTT(3'MAfN ELEC RH1 AREAB 148,E 120 480 '120 480 3 1 :3. 3 N Y N Y N 20.CTi 20 U0 .._. - 8.00 27, "' - 021% : C3'E'�h 063"k #8 #12 #1T k12 #14 872 #1"r! 1 5 1 3kP` 1t2" `(zt ley clindensale Pump CPfAHE, 3 AREA B- 120 1 Y ':` 5.0 CPL 1 20 t 99% # 12 # 1Z # t2 1 192^ AHU,4 AREA, B 480 9 N _- { HS 25 005% .. #10 #14 1 11T (c) 5.4 , fL1 20 1T H-45 20 -`-'-'F- - a (r # -.._ r„PL5 :2i1 H45 15 5.0 CPL2 20 HH5 L*4 5.4 _. aPL2 20 HH5 40 .4 �_ C,PL1 20 I .. - _ 1 25 DSmH-1 ! I15 USfpFl-2 :H-3 -- -- - -- -- :BiCH-2 500 I ;PI 1 20 0 , li ,rii 40 153% 102% #12 N12 012 912 #12 1 1 11T 112'. l4 CCnQanSa�PunpCPFAHU-4 - _ AHU-5 AREAB AREA 124 480 1 3 Y '.N .._, 7 75u I - - 2-Q0 _ - - - '� 15,E _. _ � .--_. _ 76 -. 7' I _ - _ 4 � 1 � -.. _ 0 `s � � " 050 i 1 i �... Lj ' 0,25 `� 1 ®__. _____._...,.., ..__- ,_,_...-.. ...,. 1830k 012 1 #12 #12 1 112,.. Condele,Puntp CP/AHU-5 nsa AREAS 120 T "Y 054"!0 #12 912 1 112, (C) AHU6 AREAA 486 B N..1 1 S3°b #42 #12 #12 1 VT Catcd#tlsa Purc4r.CPlAHU, AREA.A 120 i Y 0101/4 #12 #12 1 V2" (C) AREAA 4011. $ N 0.92% #12 #12 #12 1 112" Gnndensa PuY41CP✓AHU•7 AREAA 120 t Y 084% 214% #10 #12 #12 #10 012 1 ! V2` 112 1Ck AHU-8 Cvndensa4Pu GPtAHU•B AREAA AREAA 480 120 3 1 N Y 2iri7A 0;11% 91 #& 1 1-112" itH-1 AT AMU•9 480 3 N 200A 60A 017% 089% #9 #6 #fi #10 , 1 1 7-112". 4" :. DH Z DH 3 AT AHU-2. AT AHU-5 480 3 S. N N 090% #310 02 2 2" t>] CH..t CH PLANT OUTSIDE 486 3 N 0B6`;1. #3J0 #2 2 _ CH-2 CH PLANT OUTSIDE 4Qt7 3 N eC9$ 1101% # 10 #10 # 90 #t0 #10 1 1 12 112" (e) ICE'STORd TANK 4 r CKV-1P CH PLANT OUTSIDE CH PLANT OUTSIDE 120 480 4 3 Y N 1G9°tfl #10 : #10 1 1fT C.1 CHWP-2P CR I PLANT OUTSIDE 480 3 N CHWP-A$,.. GHWP-25 CHPLANT OUTSIDE CH PLANT OUTSIDE 480` 460 3 _,(., 3 N N E y EXLRR 29. 24 073% 0,80°h #12 #12 #12 #12 3 1 1f2" 1/2 (c) { 15 DSISC-1 30A tee% #10 #10 1 li2" Blower Cog Un1BCUA OFPiCE STOfMM 149 --- 208 3 N 20 MMSI I 491'4 012 #12 032 1 112" ExW,st afcF R-1 STuRM,WRTH` STORAGE149 120 1 Y t � EX LRR 20 MMS 0,61% #12 #12 #12 1 112" ExhauslFan EF-2 REST RM, SOUTH @ STORAGE 149 120 1 Y EXL1 20 MM5 2.39%. #12 #12 #12 1 4Y1" Oil ExhauslFanEF-3. HEALT14PEPT AREAA 120 1 Y � EXLG 20 MIMS 1„7 12 #12 #1$ 1 .. td2° 1b1 ExhaustPanEF-4 MEZZANINE AREA A 120 1 Y ', { 40, A 40 = ' a.Q 3. 20 2..... 2ci. i,. €_.._.-'.,,,,,,,, EX LT EXLRR CPL2 CPL2 CPL2 CPL1 CPL1 _MDP2 20 95 2i7 20 20. 20 24 20 MIMS 024A6 2,3`,}°1a. 0 42% 0,12% 012`A.......i9t2 092% 092% 420% N 12 #1Q # 12 912 012 #12 #12: # t? #9G # 12 # 12 #9"z #12 #12 #12 # 12 412 #12 #12 #12 #12 #12 #12 : t 1 t 1 1 1 1 1 112" 112" 112 I12" 1t2" 112" 1t2" 1f2". ExllausiFan EF-5 MOTORIZE,DOUTDOOR AIRUAMAPER Glycol kpmwgem ftf System Goieral Purpw,, Re0ePode GREEN COLOR AREA B: NEARBCU 1 AT CHILLER PUMPS AT CHILLER PUMPS 120 1210 i20 120 1 1. 1 1 Y Y Y Y Y Y Y Y.w_ BMSRecep# Receptac�atChatIerYwd Re(*pmrkatChillerYard SI9eLs 119atChtlerYar4 AT CHILLER PUMPS... INTEGT2AI-.'tViT-HCHILLER CHs1 INTEGRALNBTH:CHILLERtCH-2 ATCH1LL±rRYARD 120 120 120 2T7• 1. 1 1 1 (1) - PROVIDE DISC SW AT ALL PIECES OF EQUIPMENT, UNLESS OTHERWISE NOTED ON THIS SCHEDULE. (2) c B- STARTER. DISC & FUSE S'ZES SHOM FOR REFERENCE ONLY, kt AS RECOMMENDED BY EQUIPMENT MANUFACTURER. VERIFY REQUIREMENTS WITH APPROVED EQUIPMENT SHOP DRAWINGS Q3) - PROVIDE NEMA OUTDOOR RATED ENCLOS1)RES FOR ALL DISC SWS MOUNTED OUTDOORS (4) COORDINATE STARTER TYPE WITH EQUIPMENT PROVIDER (5) - E,C TO VERIFY THAT C S'S FOR MOTORS ARE SUFFICIENT TO ALLOWSTARTING Or MOTOR, IF REQUIRED FOR STARTING C B TO BE INCREASED TOAMAX OF 225% OF LARGEST MOTOR F L A t6} INCREASE FEEDER SIZES AS RE 2(JTRED TO MAINTAIN A MAXIMUM OF 7 5% VOLTAGE DROP BASED ON .ACTUAL FEEDER Lc'-1VCTHS:AS1NSTALLEO. l7) - TOTAL AMPS SHOWN DO NOT INCLUDE NOWCONCTDENTTALLOADS ABBRIMATIONS: N F = NON FUSED MCP = MOTOR CIRCUIT PROTECTOR C.8. C,L = THERMAL OVER LOAD ELEMENT MMS = MAN. MTR STARTER 20A SW. WITH O-L. AND PILOT 1- NEMA I ENCLOSURE MSS _k4OTOR STARTING 20A SW VATHOUT 01 3R NEMA 3R ENCLOSURE VFD- VARIABLEFREO DRIVE, UNIT', 4SS-INEMA4W.P SIARNLESSSTI nEENC:I CBMC -COMB DISC(MCP) AND MAG, MOTOR,STARTERIMMC) MMC = MAGNET IC MOTOR CONTROLLER W; 7.L (a) - CONNECT VIA LINE V%TAGE T$TAT. FURNISHED BY DIV 15 CONTRACTOR tb) - CONNECT VIA CONTROL DEWCES FURNISHED BY DIV 15 CON TRACTOR (e) - CONNECT VIA VFD FURNISHED BY DIV 1SSCONTRACTOR, (d) • CONNECT VIA STARTER FURNISHED BY DIV 15 CONTRACTOR, (el CONNECT VIA UNIT MTD DISC,Si"J FURNISHED BY DIV 15, (fl -CONNECT VIA STARTER FURNISHED W€THE=PMEHT (g) - INSTALL AND CONNECT CONTROLLERS& WTCHES FURNISHED WITH EQUIP (h) - CONNECT VIA STARTER IN MCC (FURNISHED BY DIV 16) It) CONNECT VIA HOOD CONTROL SYSTEM. (I) CONNECT VIAEXTERIGR ENCLOSED CIRCUIT BREAKER PANEL FEEDER SCHEDULE J0B NUMBER: 14003 OATS: 06127(15 FEEDER SERVING CIRCUIT SPEAKER FEEDER FEEDER CAPACITY VOLT DROP ,.% FEEDER AMP SIZE VOLTS PHASE. PARALLEL RUNS. PHASE WRE NEUTRAL WRE GROUND WIRE ISOLATED GROUND COPPERf ALUMINUM CONDUIT SIZE PANEL66ARDHH4' _.YCHILLER. 225 480 3 230 13" 1 #40 #40 #4 NIA CCPPER 3' PANELBOARD HH5 225 480 3 230 i 1 #4d0 #410 #4 NIA COPPER Y CH-1 500 480 "� 510 0.5E 2 #260... 9250 NIA NIA COPPER 3 CHILLER, CH-2 500 420, 3 510 062 2 #25q #250 NIA NIA COPPER 3' PANELBAORD MDP2 8(O 480 3 620 0,84 2 #350 #350 NIA NIA COPPER 3" 30WATRANSFORMER. T-CPLI 50 480 3 1 50 0,23 1 #8 NA #10 NIA COPPER 314" PANELBOARDCPLi 100 208 3 1 100 0,17 1 #3 #3 #6 NIA COPPER 1.114" PANELBOARDCPHI 225 1 480 3 1 230 1.02 1 #410 44E #6 NIA COPPER 2.112" 34kVATRANSFORMER, T-CPL2 50 48E 3 5Q il:ti 1 #B NIA. #10 N!A COPPER 3i4" PANELBCARDCPL2 100 208 3 1 100 0.1i 1 #3 #3 1 #6 NIA COPPER 1-114" Sims Wilkerson 0 Engineering, In 12124 High Tech Avenue - Suit 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-59( CERT. OF AUTH. NO. 6106 • GARY A WD-hbFSON, PP 43161 O RILE I. CA =R, P.E. 5329 o A Ml S UE , P.E. 77010 o ✓E>R A }gtRM N, P.E. 65619 •SAN LR. ALE\AN ER PE, 554R 14001 0', STATE OF ;1Q� A%4ORIQP. LL J U � o U °' W J C I O W .O M _> W O > J U oI W = J Q > LL �C) '^ VJ �'}/^1: VJ i l iIN OPTIONS REQUIRED PANEL: 4 # P+■ r-NEW ; w DATA ENCLOSURE yy VOLTS PH, RATED: { PHASE: 3 GFI • ROAMPSSECTIONS, • RFACE SHUNT TRIP:r 0 MFR SEE SPECS •* :r PROVIDE • a y. i a• DEPTH: TYPE SEE SPECS .h.r. AIC RATING RATED).; 35 6 (MINIMUM, SEE SPECIFICATIONS) u DESCRIPTION s._. • � • . r w �„> �i r :.:.• r:Yr ay �I II I� #iuu i r•aU.I " �r'� '� Yw r ' WWI 1 ... MINN IA•1 UlAlUl11111111••1�•1••IIIII on"NI f X y h 0, I - , i AMPS KVA 71 AMPS PHASE A AL CONN. LOAD 71 59 71 AMPS PHASE 8 NEC DEMAND PANEL NOTES: VOLTS L-N : 217 MAIN OPTIONS REQUIRED SWBRD : SWITCHBOARD MDP • EXISTING ENCLOSURE DATA VOLTS PH, :480 S. W, RATED: YES MCB : N/A AMPS NEMA : 1 PHASE: 3 GFI PROT, : MLO: 2000 AMPS SECTIONS :1 MOUNTING: SURFACE SHUNT TRIP: VVIDTHISECT.:36 MFR: SQUARE D EXISTING SWITCHBOARD TO REMAIN DEPTH: 36 TYPE: QED 2 AIC RATING (FULLY RATED): 100 kA NOT11 ES DESCRIPTION LOAD AMPS AMPS AMPS FUSE CKT, CKT, FUSEI AMPS AMPS AMPS LOAD DESCRIPTION NOTES CONN AMPS, POLES NUM. NUM. POLES AMPS CONN PANELHMB 0 �sy 3 1 m REFRIGERATION 0/1 .'r..T.r`. 0 `m c.s:r �r PANEL HH3 0 ,� 3 S—VA TCHEIOARDSE 4 0 AMPS KVA 0 : AMPS PHASE A ACTUAL CONN. LOAD: 0 0 0 ;AMPS PHASE B NEC DEMAND: 0 0 0 : AMPS PHASE C PANEL NOTES: VOLTS L-N : 277 MAIN OPTIONS REQUIRED SWERD : SWITCHBOARD SE -EXISTING ENCLOSURE DATA VOLTS PH.: 480 S.E. RATED: YES MCB : WA ,AMPS NEMA :1 PHASE: 3 GFI PROT, : MLO : 1600 AMPS SECTIONS: 3 MOUNTING: SURFACE SHUNT TRIP: WIIDTHISECT.:30 MFR : GE EXISTING SWITCHBOARD TO REMAIN DEPTH : 24 TYPE: AV -LINE Alfa RATING (FULLY RATED): 65 kA NOTES DESCRIPTION LOAD AMPS AMPS AMPS' FU 1 CKT CKT, FUSE AMPS AMPS AMPS LOAD DESCRIPTION NOTES CONN' AMPS POLES NUM, NUM. POLES AMPS COIN SPACE 0 3 3 0 SPACE q SPACE 3 3 D SPACE s w r 3 4 w acs q seas �..�� q SPACE 0 3 3 II SPACE q 0 PANEL HL 0 300 3 3 600 ti PANEL HE � s / 0 Mrin ai 7 8 =Az 20= 0 m®S a� SPACE 4 3 3 llK SPACE 0 10 1 0 lb y.IdL fi 0 .mew TRANSFORMER TR 3tIfJ 3 3 iflQ 0 ;: PANEL HH x» 11 12 -- -W 0 AMPS KVA 0 : AMPS PHASE A ACTUAL CONN, LOAD: 0 0 0 : AMPS PHASE B NEC DEMAND: 0 0 0 : AMPS PHASE C PANEL NOTES'. Sims Wilkerson Caj Engineering, Inc 12124 High Tech Avenue - Suite. 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-5900 CERT. OF AUTH NO.6106 0 oMY \ 0.kah RSO N, t L 41167 0 KYLE L l %R FER RE 534 9 •AD %ls LIMA]] PL. 77N. • En 4 6L KNIAN FE.6 629 •SA LLR U_ESAMV F.F. 55422 14001 N, W O LL �ALE'�9/////i 'COOe�'J'y0k3 5 ; � STATE OF 0 P: 2 /ONAI IE J Q U_ L) U o 0 w o J J C:LL W >, 0 >, +- -_• LLI O > O U o U U V 'V LLJ U = J Q J v) U) = cn W D U) U) N p O R MI REQUIRED°' and H EXISTING ENCLOSURE DATA VOLTS SECTIONS N40UNTING: SURFACE SHUNT TRIP: NIA WIDTWSECT, 20 MFR: GE RENOVATE EXISTING 4 PANEL DEPTH: TYPE: COB Sam F1011 NO m ,om w " t t�. .4 M1 =MMMMM E WI tt �WI .� MI' >r , aAM1 ���� 11111110111MIM ® !A!fi st 11 i... rAlWIWI®Mm� MWMMm"mIW1 M1���a'/�//�//�/�',' M1N � will 0 ; AMPS PHASE A 0 : AMPS PHASE, B 0 ;AMPS PHASE C AMPS KVA ACTUAL CONN. LOAD: 0 0 NEC DEMAND; 0 0 SEE THE ONELINE DIAGRAM FOR DEMOLITION REQUIREMENTS FOR THIS CIRCUIT, AND THE RENOVATED PANEL SCHEDULE THIS SHEET, tL NOTE: SEE THE ONELINE DIAGRAM FOR REQUIREMENTS ON ADDNG NEW BREAKERS TO THIS OBSOLESCENT PANEL. RAIN OPTIONS REQUIRED PANEL. HH (NH1 and HH2) - RENOVATED ENCLOSURE DATA S.E RATED: NIA MOB: NIA AMPS NEMA : 1 GPI PROT.: NIP, MILD : 800 AMPS SECTIONS: 2 SHUNT T IV NYA wfiLvnT 0 VOLTS L-N ' 277 VOLTS PH.: 480 PHASE: 3 MOUNTING: SURFACE MFR : GE TYPE: CCB f1L M11 III -WI NIMMMM MMI MM ,..... IN M1 Ml Mll M1 f f f _� mmm®mmm�°:x gym ® Ml .. �r� MM� . Dim M1 IMIN I IM1111 M1 ©- MWIffamm MM"M"=WAIM1M-�W WINIMMMM WIEwmMM WARM a AMPS KVA ACTUAL CONN, LOAD: 3<3 327 NEC DEMAND: 383 327' f �ABEL EXISTING GE TYPE TED BREAKER AS 4SPARV Y.r EXISTING w, HAS t .. i yy ,y N'EMOVE EXISTING GE fBREAKERS. 14 M IR'. GE HARDWARE t! f T > ! M SIDE. Sims Wilkerson C Engineering, Ir 12124 High Tech Avenue - Su 200 Orlando, Florida 3281' (407)380-0400 FAX (407)380-5- CERT OF AUTH. NO. 610 o GAM A VWI L ,R90N.1 L,. Y3167 O k 1 C Nidl It P I',. 53269 0 AMM S I F\ INF P L. 77016 *JL1-f MMIAXPF.. W29 • SAWTI 2 V I X.A>DEIy P.L.5M22 14001 CEN, ;WtiO �4.bklu a FLOR`�P?` sS/ONAI \\aG\�� J Q f— to N I J O M W +� , O co > LJ O E-- U o C U W 0 W .' U J w U) (n 2 C O LO 0 (V 0 O W (\ C'�) NT 1 _ !1 W ,TS L-N .120 ,TS PH, 208 6E : 3 • �- w •rl1 r• r - +� r RATED GFI Mpl 1 SHUNT TRIP: NIA PANEL: LRR -EXISTING MCB : 110 AMPS MLQ: NIA AMPS AIC RAT ING(FULILY RATED): 22 kA ENCLOSURE DATA NEMA,1 SECTIONS: 2 °d DTHISE^T.:20 DEPTH ; 5 � wx M M ♦ � .. � �. Recept- Jan Closet / 01,111,111,1111, D II I ��,y��,,��_': IM I ENEMMEER �':..=. ff i E EMMMEE Elm M MEMM6 • _011 I • I=FMMM «i"f f. .-. rA ,< � I I x. xi WMEEN i win . , : f M �� M[Mr - . iNo M elf f M - � i f In low ff -♦ xa � IRA :.} p I ism ._ mmm AMPS KVA ACTUAL CONN. LOAD 96 34 NEC DEMAND: 72 26 1 PROVIDE A NEW BREAKER WITH POLES INDICATED IN EXISTING SPACE(S) WITH AMPERAGE INDICATED, AND WITH AIC RATINGS AND TYPE TOMATCH EXISTING PANEL. IVOLTS L-N: 120 MAIN OPTIONS REQUIRED PANEL: CPLI -NEW ENCLOSURE DATA iyu LTS V # 4 f5FI RATED: x 100 x.rT, NIA r NIA AMPS SECTIONS: 1 MOUNTING SURFACE TRIP:: SHUNT NIA i PROVIDE '!TYPE: «♦ i kA (MINIMUM) 11 IIII I I IIIiIIIIIiiwIIIIIIIIi `DESCRIPTION M ! M Y '4 M. } b M: 11 II 41 r. DESCRIPTION �xM ' ri • rl` # y1 4N1 • Y F I : - •I�II�•II•, M i. MUT f • il. • . y _ i �, • x i ! i gti ry Y { WE I xa. av • MFM f• p.f ^rii �x +a UFO, MUM V HIM, AMPS KVA y AMPS PHASE0 ACTUAL CONN r I. 15 AMPS PHASEM NEC DEMAND: ; V 15:AMPSPHASEC EANEL NOTES: VOLTS L-N :120 14OLTS PH.: 208 PHASE: 3 MOUNTING: SURFACE MFR : MAIN OPTIONS REQUIRED S E. RATED.- N/A CFI PROT.: NIA SHUNT TRIP: NIA PANEL: (;PL2 • NEW MCB: 100 AMPS MLC : N)A AMPS AIC RATING (FULLY RATED): 10 kA (MINIMUM) ENCLOSURE DATA NEMA:1 SECTIONS :1 WIDTH/SECT. j 20 DEPTH: 6 Bravo= DESCRIPTION , I , mr I t FASO= f: 0... 0100MM3.111 PAW In . IIImo�!! KE •®� I p A FA x . P� SPACE ,.. •r SPACE tSPACE no AMPS KVA ACTUAL CONN, LOAD : 14 5 NEC DEMAND: 14 5 Sims Wilkerson Cartier Engineering, Inc. 12124 High Tech Avenue - Suite. 200 Orlando, Florida32817 (407)380-0400 FAX (407)380-5900 FL. CERT. OF AUTH NO. 6106 *eMZYAINiL RSO,C PE 43167 o KMI 7 CARiR IL C.F. 3_69 O Mkm S. UNTNL PE 77010 o EF A RMKM N 65629 6 • WCTL R. A E6 A\TIE$ PL. 55423 14001 �4 3 I p', STATE OF o 001111100 Q U (U U v' 0 N U J I O LL J C 0 W _ _a . 2 �+ f `I I � L LU I 0 > 0 F= � U U o U 0 LIJ .0 U � U Lu J Q J a-= U > 0� U) Cn 2 Cn O LL o N 0 p W o d- A 1 _ VJ W MAIN OPTIONS i PANEL: t "- NEW ENCLOSURE DATA VOLTS PH,: ;1 SECTIONS IMOUNTING SURFACE SHUNT TRIP: NfA i 1 PROVIDE E E • TYPE AIC RATING (FULLY D. win ARM RM11200 I' �M� _. M mmmm .1 ■ ®■MS M 9 MIMIMMENIM �� ® r MIM MIM E y AMPS KVA 1 ONN. LOAD ; 105 AMPS PHASE B NEC DEMAND: A 92 AMPS PHASE C i OPTIONS REQUIRED PANELNEW DATA r .1 S.E. RATED 'i iSECTIONS: iMOUNTfNG: SURFACE SHUNT TRIP: NIA E A' PROVIDE"PANELDEPTH: TYPE AIC RATING (FULLY r DE SCRIPTION DESCRIPTION 7W NOME mesa== ® • • 0 ®MI Ml=law Nam■ ■ ® ®■®�®■■■ Ah �I ' M. r ® �® i E ,. EMS ME BOMMS mm me MWIMM IM FJA M1 I MMMMIMM 1 0 =M ■ ® ■� - = FM■ M ■ 131 ; AMPS PHASE A 131 ; AMPS PHASE B 131 : AMPS PHASE C AMPS KVA ACTUAL CONN. LOAD: 131 109 NEC DEMAND: 131 109 VOLTS L-N: 277 MAIN OPTIONS REQUIRED PANEL: CPHI -NEW ENCLOSURE DATA i to S,E, RATED `E i MOUNTING: SURFACE, E 1 ! a i ` ! PROVIDE PANEL AIC RATING (FULLY ` El DESCRIPTION ME= EMMMI SPARE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE Sims Wilkerson Cartier Engineering, Inc. 12124 High Tech Avenue - Suite. 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-5900 FL. CERT. OF AUTH. NO, 6106 0 OARY X N71,K8RSOX P.E. 43167 O 1. CA M-R, P.P. 53269 O gpeVNS. U`ouv, PE. 77010 o IEFF A HIX , RE, 65629 ! SAM[lEi R e1LE,\ANDEP, P.E. 55122 14001 STATE OF %"A- s�)NAL F7 I J H I' V Q U M N \ w J J C u- O LU O f C L rl //1� L. J 1 0 > 0 � � U o U w o � U w = J Q J U > U) 4-: (n 2 (n O Lo LL o 0 w �� � � o ti w E! SECTION 260500 - BASIC ELECTRICAL REQUIREMENTS PART 1-GENERAL IA RELATED DOCUMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING CONTRACTUAL CONDITIONS AND OTHER DIVISION 1 SPECIFICATION SECTIONS APPLY TO THIS SECTION. 1.2 WORK INCLUDED A. THIS SECTION INCLUDES BASIC ELECTRICAL REQUIREMENTS SPECIFICALLY APPLICABLE TO DIVISION 26 SECTIONS. B. PROVIDE AND INSTALL ALL EQUIPMENT, LABOR, MATERIAL AND ACCESSORIES, AND MOUNTING HARDWARE FOR A COMPLETE AND OPERATING SYSTEM AS DESCRIBED WITHIN THESE DIVISION 26 SPECIFICATION SECTIONS. C. FURNISH, PERFORM, OR PROVIDE ALL LABOR INCLUDING PLANNING, PURCHASING, TRANSPORTING, STORING, INSTALLING, TESTING, COORDINATION, FIELD VERIFICATION, INSTALLATION SAFETY, SUPPLIES, AND MATERIALS NECESSARY FOR THE INSTALLATION OF COMPLETE ELECTRICAL SYSTEMS (AS DESCRIBED OR IMPLIED BY THESE SPECIFICATIONS AND THE APPLICABLE DRAWINGS) IN STRICT ACCORDANCE WITH SAFETY STANDARDS AND APPLICABLE CODES, WHICH MAY NOT BE REPEATED IN THESE SPECIFICATIONS, BUT ARE EXPECTED TO BE COMMON KNOWLEDGE OF QUALIFIED BIDDER. D. MAKE CONNECTIONS TO ALL ITEMS IN THE WORK WHICH REQUIRE ELECTRIC POWER. CONNECTIONS WILL INCLUDE WIRE, CONDUIT, CIRCUIT PROTECTION, DISCONNECTS, AND ACCESSORIES. SECURING OF ROUGHING -IN DRAWINGS AND CONNECTION INFORMATION FOR EQUIPMENT INVOLVED IS INCLUDED UNDER THIS DIVISION. SEE OTHER DIVISIONS FOR SPECIFICATIONS FOR ELECTRICALLY OPERATED EQUIPMENT. E. SECURE AND PAY FOR ALL PERMITS, FEES, LICENSES, AND INSPECTIONS REQUIRED TO PERFORM DIVISION 26 WORK. F. PROVIDE TEMPORARY ELECTRICAL SERVICE, POWER, AND LIGHTING FOR CONSTRUCTION. 1.3 WORK SEQUENCE A. INSTALL WORK IN STAGES OR PHASES TO ACCOMMODATE OWNER AND CONSTRUCTION MANAGER. 1.4 DESCRIPTION A. INSTALL WORK IN LOCATIONS SHOWN OR DESCRIBED IN THE CONTRACT DOCUMENTS, UNLESS PREVENTED BY PROJECT CONDITIONS. B. INSTALL ALL EQUIPMENT SO THAT ALL CODE AND MANUFACTURER RECOMMENDED WORKING AND SERVICING CLEARANCES ARE MAINTAINED, PROPERLY ARRANGE AND INSTALL ALL EQUIPMENT WITHIN DESIGNATED SPACES. IF A DEPARTURE FROM THE CONTRACT DOCUMENTS IS NECESSARY, SUBMIT TO THE ENGINEER FOR APPROVAL, DETAILED DRAWINGS OF THE PROPOSED CHANGES WITH WRITTEN REASONS FOR THE CHANGES. NO CHANGE SHALL BE IMPLEMENTED WITHOUT APPROVAL AS PERMITTED BY THE GENERAL CONDITIONS. 1.5 INVESTIGATION OF SITE A. INVESTIGATE THE SITE AND EXISTING CONDITIONS THOROUGHLY BEFORE BIDDING. B. DURING THE COURSE OF HIS SITE VISIT, THE ELECTRICAL BIDDER SHALL BECOME FAMILIAR WITH ALL ASPECTS OF THE PROPOSED WORK AND EXISTING FIELD CONDITIONS OF THE WORK. NO COMPENSATION OR REIMBURSEMENT FOR ADDITIONAL EXPENSES FOR FAILURE INVESTIGATE THE EXISTING FACILITIES WILL BE AUTHORIZED. THIS SHALL INCLUDE REROUTING AROUND EXISTING OBSTRUCTIONS, C. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. 1.6 CONTRACT DOCUMENTS SITE A. THE DRAWINGS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO INCLUDE EVERY DETAIL OF CONSTRUCTION, MATERIALS, METHODS, AND EQUIPMENT, THEY INDICATE THE RESULT TO BE ACHIEVED BY AN ASSEMBLAGE OF VARIOUS SYSTEMS. COORDINATE EQUIPMENT LOCATIONS WITH AND PLUMBING. LAYOUT EQUIPMENT BEFORE INSTALLATION SO THAT ALL TRADES MAY INSTALL EQUIPMENT IN SPACES AVAILABLE. COORDINATE INSTALLATION IN A NEAT AND WORKMANLIKE MANNER. 1.7 MATERIALS AND EQUIPMENT A. UNLESS OTHERWISE NOTED, ALL MATERIAL SHALL BE NEW AND U.L. LISTED OR LABELED. IN LIEU OF UL LISTING OR LABELING, A STATEMENT OR DATA DEMONSTRATING COMPLIANCE WITH CONTRACT DOCUMENTS FROM A NATIONALLY RECOGNIZED TESTING AGENCY SHALL BE SUBMITTED FOR APPROVAL. B. WHERE MULTIPLE ITEMS OF THE SAME EQUIPMENT OR MATERIALS ARE REQUIRED, THEY SHALL BE THE PRODUCT OF THE SAME MANUFACTURER. C. PRIOR TO PLACING EQUIPMENT ORDERS, VERIFY THE PHYSICAL SIZE OF SPECIFIED EQUIPMENT TO FIT SPACES ALLOTTED ON THE DRAWINGS AND WITH NEC WORKING CLEARANCES. D. INSPECT ALL ELECTRICAL EQUIPMENT AND MATERIALS PRIOR TO INSTALLATION. DAMAGED EQUIPMENT AND MATERIALS SHALL NOT BE INSTALLED OR PLACED IN SERVICE. REPLACE OR REPAIR AND TEST DAMAGED EQUIPMENT IN COMPLIANCE WITH INDUSTRY STANDARDS AT NO ADDITIONAL COST TO THE OWNER. 1.8 SUPERVISION OF THE WORK A. A QUALIFIED AND EXPERIENCED ELECTRICAL SUPERINTENDENT SHALL BE IN CHARGE OF THE WORK IN PROGRESS AT ALL TIMES B. PROVIDE FIELD SUPERINTENDENT WHO HAS HAD A MINIMUM OF FOUR (4) YEARS PREVIOUS SUCCESSFUL EXPERIENCE ON PROJECTS OF COMPARABLE SIZES AND COMPLEXITY. SUPERINTENDENT SHALL BE PRESENT AT ALL TIMES THAT WORK UNDER THIS DIVISION IS BEING INSTALLED OR AFFECTED 1.9 COORDINATION A. PROVIDE ALL REQUIRED COORDINATION AND SUPERVISION WHERE WORK CONNECTS TO OR IS AFFECTED BY WORK OF OTHERS, AND COMPLY WITH ALL REQUIREMENTS AFFECTING THIS DIVISION. WORK REQUIRED UNDER OTHER DIVISIONS, SPECIFICATIONS OR DRAWINGS TO BE PERFORMED BY THIS DIVISION SHALL BE COORDINATED WITH THE CONTRACTOR AND SUCH WORK PERFORMED AT NO ADDITIONAL COST TO THE OWNER INCLUDING BUT NOT LIMITED TO ELECTRICAL WORK REQUIRED FOR: 1. MECHANICAL DIVISION OF THE SPECIFICATIONS B. COORDINATE THE EXACT LOCATION OF WALL OR FLOOR PENETRATIONS WITH THE OWNER AND ENGINEER. C. THE CONTRACT DOCUMENTS DESCRIBE SPECIFIC SIZES OF SWITCHES, BREAKERS, FUSES, CONDUITS, CONDUCTORS, MOTOR STARTERS AND OTHER ITEMS OF WIRING EQUIPMENT, THESE SIZES ARE BASED ON SPECIFIC ITEMS OF POWER CONSUMING EQUIPMENT (HEATERS, LIGHTS, MOTORS FOR FANS, COMPRESSORS, PUMPS, ETC.). COORDINATE THE REQUIREMENTS OF EACH LOAD WITH EACH LOAD'S RESPECTIVE CIRCUITRY SHOWN AND WITH EACH LOAD'S REQUIREMENTS AS NOTED ON ITS NAMEPLATE DATA AND MANUFACTURER'S PUBLISHED ELECTRICAL CRITERIA. ADJUST CIRCUIT BREAKER, FUSE, CONDUIT, AND CONDUCTOR SIZES TO MEET THE ACTUAL REQUIREMENTS OF THE EQUIPMENT BEING PROVIDED AND INSTALLED AND CHANGE FROM SINGLE POINT TO MULTIPLE POINTS OF CONNECTION (OR VICE VERSA) TO MEET EQUIPMENT REQUIREMENTS. CHANGES SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. 1.10 DELIVERY, HANDLING, PROTECTION OF MATERIALS, AND STORAGE A. STORE ALL EQUIPMENT AND PRODUCTS IN CLEAN, DRY SPACES. PROTECT ALL EQUIPMENT FROM DIRT, FUMES, WATER, CHEMICALS, CONSTRUCTION DEBRIS AND PHYSICAL DAMAGE. ANY EQUIPMENT EXPOSED DIRECTLY TO MOISTURE WILL NOT BE ACCEPTABLE AND SHALL BE REPLACED. B. REPLACE DAMAGED PRODUCTS AND EQUIPMENT. REPAIR AND REPAINT MARRED AND DAMAGED FINISHES TO ORIGINAL FACTORY FINISH AS DIRECTED BY MANUFACTURER AND AS HEREIN SPECIFIED. 1.11 INSTALLATION A. ERECT EQUIPMENT TO MINIMIZE INTERFERENCE AND DELAYS WITH THE EXECUTION OF THE WORK. B. TAKE CARE IN ERECTION AND INSTALLATION OF EQUIPMENT AND MATERIALS TO AVOID MARRING FINISHES OR SURFACES. ANY DAMAGE SHALL BE REPAIRED OR REPLACED AS DETERMINED BY THE OWNER AT NO ADDITIONAL COST TO THE OWNER. C. EQUIPMENT REQUIRING ELECTRICAL SERVICE SHALL NOT BE ENERGIZED OR PLACED IN SERVICE UNTIL THE OWNER IS NOTIFIED AND IS PRESENT OR HAVE WAIVED THEIR RIGHT TO BE PRESENT. WHERE EQUIPMENT TO BE PLACED IN SERVICE INVOLVES SERVICE OR CONNECTION FROM ANOTHER CONTRACTOR, NOTIFY THE OWNER IN WRITING AS APPROPRIATE WHEN THE EQUIPMENT WILL BE READY. D. EQUIPMENT SUPPORTS SHALL BE SECURED AND SUPPORTED FROM STRUCTURAL MEMBERS UNLESS WRITTEN APPROVAL IS GRANTED BY THE OWNER. 1.12 AS -BUILT DOCUMENTS A. AS -BUILT DOCUMENTS: AS -BUILT DOCUMENTS INCLUDE DRAWINGS, SHOP DRAWINGS, SPECIFICATIONS, ADDENDA, CHANGE ORDERS, AND OTHER MODIFICATIONS PERMITTED BY THE GENERAL CONDITIONS, B. VERIFY ASPECTS OF REDLINED AS-BUILTS FOR ACCURACY, AS -BUILT DOCUMENTS SHALL SHOW ALL COMPONENTS OF INSTALLATION, 1.13 SYSTEMS WARRANTY A. WARRANTY SHALL BE BY THE CONTRACTOR TO THE OWNER AND SHALL COVER FOR A PERIOD OF ONE YEAR FROM THE DATE OF THE SUBSTANTIAL COMPLETION. B. WHERE ITEMS OF EQUIPMENT OR MATERIALS CARRY MANUFACTURER'S WARRANTY FOR ANY PERIOD IN EXCESS OF TWELVE (12) MONTHS, THEN THE MANUFACTURER'S WARRANTY SHALL APPLY FOR THAT PARTICULAR PIECE OF EQUIPMENT OR MATERIAL. 1.14 WASTE MATERIALS DISPOSAL A. INCLUDE IN BASE BID THE TRANSPORT AND DISPOSAL OR RECYCLING OF ALL WASTE MATERIALS GENERATED BY THIS PROJECT IN ACCORDANCE WITH ALL RULES, REGULATIONS AND GUIDELINES APPLICABLE, COMPLY FULLY WITH FLORIDA STATUTE 403.7186 REGARDING MERCURY CONTAINING DEVICES. MATERIALS SHALL BE TRANSPORTED AND DISPOSED OF IN ACCORDANCE WITH ALL DEP AND EPA GUIDELINES APPLICABLE AT TIME OF DISPOSAL. PROVIDE THE OWNER WITH WRITTEN CERTIFICATION OF APPROVED DISPOSAL. 1,15 PROHIBITION OF ASBESTOS AND PCB A. PRIOR TO THE FINAL REVIEW FIELD VISIT THE CONTRACTOR SHALL CERTIFY IN WRITING THAT THE EQUIPMENT AND MATERIALS INSTALLED IN THIS PROJECT UNDER THIS DIVISION 26 CONTAIN NO ASBESTOS OR PCB. PART 2-PRODUCTS (NOT USED) PART 3 - EXECUTION (NOT USED) END OF SECTION 260500 SECTION 260519 - LOW -VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1-GENERAL 1.1 RELATED DOCUMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. 1.2 SUMMARY A. THIS SECTION INCLUDES THE FOLLOWING: 1. BUILDING WIRES AND CABLES RATED 600 V AND LESS. 2. CONNECTORS, SPLICES, AND TERMINATIONS RATED 600 V AND LESS. B. RELATED SECTIONS INCLUDE THE FOLLOWING: 1. DIVISION 27 SECTION "COMMUNICATIONS HORIZONTAL CABLING" FOR CABLING USED FOR VOICE AND DATA CIRCUITS. 1.3 DEFINITIONS A. EPDM: ETHYLENE-PROPYLENE-DIENE TERPOLYMER RUBBER. B. NBR: ACRYLONITRILE-BUTADIENE RUBBER. 1.4 ACTION SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. 1.5 INFORMATIONAL SUBMITTALS A. QUALIFICATION DATA: FOR TESTING AGENCY B. FIELD QUALITY -CONTROL TEST REPORTS, 1.6 QUALITY ASSURANCE A. TESTING AGENCY QUALIFICATIONS: AN INDEPENDENT AGENCY, WITH THE EXPERIENCE AND CAPABILITY TO CONDUCT THE TESTING INDICATED, THAT IS A MEMBER COMPANY OF THE INTERNATIONAL ELECTRICAL TESTING ASSOCIATION OR IS A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL) AS DEFINED BY OSHA IN 29 CFR 1910.7, AND THAT IS ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, 1. TESTING AGENCY'S FIELD SUPERVISOR: PERSON CURRENTLY CERTIFIED BY THE INTERNATIONAL ELECTRICAL TESTING ASSOCIATION OR THE NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES TO SUPERVISE ON -SITE TESTING SPECIFIED IN PART 3. B. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE. C. COMPLY WITH NFPA 70. PART2-PRODUCTS 2.1 CONDUCTORS AND CABLES A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. ALCAN PRODUCTS CORPORATION; ALCAN CABLE DIVISION. 2. AMERICAN INSULATED WIRE CORP.; A LEVITON COMPANY, 3. GENERAL CABLE CORPORATION. 4. SENATOR WIRE & CABLE COMPANY. 5. SOUTHWIRE COMPANY. B. ALUMINUM AND COPPER CONDUCTORS: COMPLY WITH NEMA WC 70. C. CONDUCTOR INSULATION: COMPLY WITH NEMA WC 70 FOR TYPES THHN-THWN D. MULTICONDUCTOR CABLE: COMPLY WITH NEMA WC 70 METAL -CLAD CABLE, TYPE MC AND TYPE SO WITH GROUND WIRE. 2.2 CONNECTORS AND SPLICES A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. AFC CABLE SYSTEMS, INC. 2. HUBBELL POWER SYSTEMS, INC. 3. 0-Z/GEDNEY; EGS ELECTRICAL GROUP LLC. 4. 3M; ELECTRICAL PRODUCTS DIVISION. 5. TYCO ELECTRONICS CORP. B. DESCRIPTION: FACTORY -FABRICATED CONNECTORS AND SPLICES OF SIZE, AMPACITY RATING, MATERIAL, TYPE, AND CLASS FOR APPLICATION AND SERVICE INDICATED, PART 3-EXECUTION 3.1 CONDUCTOR MATERIAL APPLICATIONS A. FEEDERS COPPER FOR FEEDERS SMALLER THAN NO.4 AWG; COPPER OR ALUMINUM (IF ALLOWED) FOR FEEDERS NO.4 AWG AND LARGER. SOLID FOR NO. 10 AWG AND SMALLER; STRANDED FOR NO.8 AWG AND LARGER, B. BRANCH CIRCUITS: COPPER. SOLID FOR NO. 10 AWG AND SMALLER; STRANDED FOR NO.8 AWG AND LARGER. 3.2 CONDUCTOR INSULATION AND MULTICONDUCTOR CABLE APPLICATIONS AND WIRING METHODS A. SERVICE ENTRANCE: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY, B. EXPOSED FEEDERS: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY. C. FEEDERS CONCEALED IN CEILINGS, WALLS, PARTITIONS, AND CRAWLSPACES: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY. D. FEEDERS CONCEALED IN CONCRETE, BELOW SLABS -ON -GRADE, AND UNDERGROUND: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY. E. FEEDERS INSTALLED BELOW RAISED FLOORING: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY. F. EXPOSED BRANCH CIRCUITS, INCLUDING IN CRAWLSPACES: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY. G. BRANCH CIRCUITS CONCEALED IN CEILINGS, WALLS, AND PARTITIONS: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY NO METAL -CLAD CABLE, TYPE MC. H. BRANCH CIRCUITS CONCEALED IN CONCRETE, BELOW SLABS -ON -GRADE, AND UNDERGROUND: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY. I. BRANCH CIRCUITS INSTALLED BELOW RAISED FLOORING: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY AND METAL -CLAD CABLE, TYPE MC. J. CORD DROPS AND PORTABLE APPLIANCE CONNECTIONS: TYPE SO, HARD SERVICE CORD WITH STAINLESS -STEEL, WIRE -MESH, STRAIN RELIEF DEVICE AT TERMINATIONS TO SUIT APPLICATION. K. CLASS 1 CONTROL CIRCUITS: TYPE THHN-THWN, IN RACEWAY. L. CLASS 2 CONTROL CIRCUITS: TYPE THHN-THWN, IN RACEWAY, 3.3 INSTALLATION OF CONDUCTORS AND CABLES A. CONCEAL CABLES IN FINISHED WALLS, CEILINGS, AND FLOORS, UNLESS OTHERWISE INDICATED. B. USE MANUFACTURER -APPROVED PULLING COMPOUND OR LUBRICANT WHERE NECESSARY; COMPOUND USED MUST NOT DETERIORATE CONDUCTOR OR INSULATION. DO NOT EXCEED MANUFACTURER'S RECOMMENDED MAXIMUM PULLING TENSIONS AND SIDEWALL PRESSURE VALUES. C. USE PULLING MEANS, INCLUDING FISH TAPE, CABLE, ROPE, AND BASKET -WEAVE WIRE/CABLE GRIPS, THAT WILL NOT DAMAGE CABLES OR RACEWAY. D. INSTALL EXPOSED CABLES PARALLEL AND PERPENDICULAR TO SURFACES OF EXPOSED STRUCTURAL MEMBERS, AND FOLLOW SURFACE CONTOURS WHERE POSSIBLE. E. SUPPORT CABLES ACCORDING TO DIVISION 26 SECTION "HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS." F. IDENTIFY AND COLOR -CODE CONDUCTORS AND CABLES ACCORDING TO DIVISION 26 SECTION "IDENTIFICATION FOR ELECTRICAL SYSTEMS." 3.4 CONNECTIONS A. TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS ACCORDING TO MANUFACTURER'S PUBLISHED TORQUE -TIGHTENING VALUES. IF MANUFACTURER'S TORQUE VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A-486B. B. MAKE SPLICES AND TAPS THAT ARE COMPATIBLE WITH CONDUCTOR MATERIAL AND THAT POSSESS EQUIVALENT OR BETTER MECHANICAL STRENGTH AND INSULATION RATINGS THAN UNSPLICED CONDUCTORS. 1. USE OXIDE INHIBITOR IN EACH SPLICE AND TAP CONDUCTOR FOR ALUMINUM CONDUCTORS. C. WIRING AT OUTLETS: INSTALL CONDUCTOR AT EACH OUTLET, WITH AT LEAST 6 INCHES (150 MM OF SLACK. 3.5 SLEEVE AND SLEEVE -SEAL INSTALLATION FOR ELECTRICAL PENETRATIONS A. INSTALL SLEEVES AND SLEEVE SEALS AT PENETRATIONS OF EXTERIOR FLOOR AND WALL ASSEMBLIES. COMPLY WITH REQUIREMENTS IN DIVISION 26 SECTION "SLEEVES AND SLEEVE SEALS FOR ELECTRICAL RACEWAYS AND CABLING." 3.6 FIRESTOPPING A. APPLY FIRESTOPPING TO ELECTRICAL PENETRATIONS OF FIRE -RATED FLOOR AND WALL ASSEMBLIES TO RESTORE ORIGINAL FIRE -RESISTANCE RATING OF ASSEMBLY ACCORDING TO DIVISION 07 SECTION "PENETRATION RRESTOPPING" 3.7 FIELD QUALITY CONTROL A. TESTING AGENCY: ENGAGE A QUALIFIED TESTING AGENCY TO PERFORM TESTS AND INSPECTIONS AND PREPARE TEST REPORTS. B. PERFORM TESTS AND INSPECTIONS AND PREPARE TEST REPORTS. C. TESTS AND INSPECTIONS: 1. AFTER INSTALLING CONDUCTORS AND CABLES AND BEFORE ELECTRICAL CIRCUITRY HAS BEEN ENERGIZED, TEST SERVICE ENTRANCE AND FEEDER CONDUCTORS FOR COMPLIANCE WITH REQUIREMENTS. 2. PERFORM EACH VISUAL AND MECHANICAL INSPECTION AND ELECTRICAL TEST STATED IN NETA ACCEPTANCE TESTING SPECIFICATION. CERTIFY COMPLIANCE WITH TEST PARAMETERS, D. TEST REPORTS: PREPARE A WRITTEN REPORT TO RECORD THE FOLLOWING: 1. TEST PROCEDURES USED. 2. TEST RESULTS THAT COMPLY WITH REQUIREMENTS. 3. TEST RESULTS THAT DO NOT COMPLY WITH REQUIREMENTS AND CORRECTIVE ACTION TAKEN TO ACHIEVE COMPLIANCE WITH REQUIREMENTS, E. REMOVE AND REPLACE MALFUNCTIONING UNITS AND RETEST AS SPECIFIED ABOVE. END OF SECTION 260519 SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1-GENERAL 1.1 RELATED DOCUMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. 1.2 SUMMARY A. SECTION INCLUDES: GROUNDING SYSTEMS AND EQUIPMENT, B. SECTION INCLUDES GROUNDING SYSTEMS AND EQUIPMENT, PLUS THE FOLLOWING SPECIAL APPLICATIONS: 1. GROUND BONDING COMMON WITH LIGHTNING PROTECTION SYSTEM. 1.3 ACTION SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. 1.4 INFORMATIONAL SUBMITTALS A. INFORMATIONAL SUBMITTALS: PLANS SHOWING DIMENSIONED AS -BUILT LOCATIONS OF GROUNDING FEATURES SPECIFIED IN "FIELD QUALITY CONTROL" ARTICLE, INCLUDING THE FOLLOWING: 1. TEST WELLS. 2. GROUND RODS. 3. GROUND RINGS. 4. GROUNDING ARRANGEMENTS AND CONNECTIONS FOR SEPARATELY DERIVED SYSTEMS. 5. GROUNDING FOR SENSITIVE ELECTRONIC EQUIPMENT. B. QUALIFICATION DATA: FOR QUALIFIED TESTING AGENCY AND TESTING AGENCY'S FIELD SUPERVISOR. C. FIELD QUALITY -CONTROL REPORTS. 1.5 CLOSEOUT SUBMITTALS A. OPERATION AND MAINTENANCE DATA: FOR GROUNDING TO INCLUDE IN EMERGENCY, OPERATION, AND MAINTENANCE MANUALS. IN ADDITION TO ITEMS SPECIFIED IN DIVISION 01 SECTION "OPERATION AND MAINTENANCE DATA," INCLUDE THE FOLLOWING: 1. INSTRUCTIONS FOR PERIODIC TESTING AND INSPECTION OF GROUNDING FEATURES AT TEST WELLS GROUNDING CONNECTIONS FOR SEPARATELY DERIVED SYSTEMS BASED ON NETA MTS. a. TESTS SHALL DETERMINE IF GROUND -RESISTANCE OR IMPEDANCE VALUES REMAIN WITHIN SPECIFIED MAXIMUMS, AND INSTRUCTIONS SHALL RECOMMEND CORRECTIVE ACTION IF VALUES DO NOT. b. INCLUDE RECOMMENDED TESTING INTERVALS, 1.6 QUALITY ASSURANCE A. TESTING AGENCY QUALIFICATIONS: MEMBER COMPANY OF NETA OR AN NRTL. 1. TESTING AGENCY'S FIELD SUPERVISOR: CURRENTLY CERTIFIED BY NETA TO SUPERVISE ON -SITE TESTING. B. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. C. COMPLY WITH UL 467 FOR GROUNDING AND BONDING MATERIALS AND EQUIPMENT. PART 2-PRODUCTS 2.1 CONDUCTORS A. INSULATED CONDUCTORS: COPPER OR TINNED -COPPER WIRE OR CABLE INSULATED FOR 600 V UNLESS OTHERWISE REQUIRED BY APPLICABLE CODE OR AUTHORITIES HAVING JURISDICTION. B. BARE COPPER CONDUCTORS: 1. SOLID CONDUCTORS: ASTM B 3. 2. STRANDED CONDUCTORS: ASTM B 8. 3. TINNED CONDUCTORS: ASTM B 33. 4. BONDING CABLE: 28 KCMIL, 14 STRANDS OF NO. 17 AWG CONDUCTOR, 114 INCH (6 MM) IN DIAMETER. 5. BONDING CONDUCTOR: NO.4 OR NO.6 AWG, STRANDED CONDUCTOR. 6. BONDING JUMPER: COPPER TAPE, BRAIDED CONDUCTORS TERMINATED WITH COPPER FERRULES; 1.5/8INCHES (41 MM) WIDE AND 1/16INCH (1.6 MM) THICK. 7. TINNED BONDING JUMPER: TINNED -COPPER TAPE, BRAIDED CONDUCTORS TERMINATED WITH COPPER FERRULES; 1-518 INCHES (41 MM) WIDE AND 1116 INCH (1.6 MM) THICK. C. GROUNDING BUS: PREDRILLED RECTANGULAR BARS OF ANNEALED COPPER,1/4 BY 4 INCHES (6.3 BY 100 MM) IN CROSS SECTION, WITH 9132-INCH (7.14-MM) HOLES SPACED 1-1/8 INCHES (28 MM) APART. STAND-OFF INSULATORS FOR MOUNTING SHALL COMPLY WITH UL 891 FOR USE IN SWITCHBOARDS, 600 V, LEXAN OR PVC, IMPULSE TESTED AT 5000 V. 2.2 CONNECTORS A. LISTED AND LABELED BY AN NRTL ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION FOR APPLICATIONS IN WHICH USED AND FOR SPECIFIC TYPES, SIZES, AND COMBINATIONS OF CONDUCTORS AND OTHER ITEMS CONNECTED. B. BOLTED CONNECTORS FOR CONDUCTORS AND PIPES: COPPER OR COPPER ALLOY, PRESSURE TYPE WITH AT LEAST TWO BOLTS. 1. PIPE CONNECTORS: CLAMP TYPE, SIZED FOR PIPE. C. WELDED CONNECTORS: EXOTHERMIC -WELDING KITS OF TYPES RECOMMENDED BY KIT MANUFACTURER FOR MATERIALS BEING JOINED AND INSTALLATION CONDITIONS. D. BUS -BAR CONNECTORS: MECHANICAL TYPE, CAST SILICON BRONZE, SOLDERLESS COMPRESSION OR EXOTHERMIC -TYPE WIRE TERMINALS, AND LONG -BARREL, TWO -BOLT CONNECTION TO GROUND BUS BAR. 2.3 GROUNDING ELECTRODES A. GROUND RODS: COPPER -CLAD STEEL, SECTIONAL TYPE; 3/4 INCH BY 10 FEET (19 MM BY 3 M) IN DIAMETER. PART 3-EXECUTION 3.1 APPLICATIONS A. CONDUCTORS: INSTALL SOLID CONDUCTOR FOR NO.8 AWG AND SMALLER, AND STRANDED CONDUCTORS FOR NO.6 AWG AND LARGER UNLESS OTHERWISE INDICATED. B. UNDERGROUND GROUNDING CONDUCTORS: INSTALL BARE COPPER CONDUCTOR, NO.2/0 AWG MINIMUM. 1. BURY AT LEAST 24 INCHES (600 MM) BELOW GRADE. C. GROUNDING BUS: INSTALL IN ROOMS HOUSING ELECTRICAL AND TELEPHONE EQUIPMENT ROOMS, IN ROOMS HOUSING SERVICE EQUIPMENT, AND ELSEWHERE AS INDICATED. 1. INSTALL BUS ON INSULATED SPACERS 21NCHES (50 MM) MINIMUM FROM WALL, 6 INCHES (150 MM) ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED, 2. D. CONDUCTOR TERMINATIONS AND CONNECTIONS: 1. PIPE AND EQUIPMENT GROUNDING CONDUCTOR TERMINATIONS: BOLTED CONNECTORS. 2. UNDERGROUND CONNECTIONS: WELDED CONNECTORS EXCEPT AT TEST WELLS AND AS OTHERWISE INDICATED. 3. CONNECTIONS TO GROUND RODS ATTEST WELLS: BOLTED CONNECTORS. 3.2 EQUIPMENT GROUNDING A. INSTALL INSULATED EQUIPMENT GROUNDING CONDUCTORS WITH ALL FEEDERS AND BRANCH CIRCUITS. B. INSTALL INSULATED EQUIPMENT GROUNDING CONDUCTORS WITH THE FOLLOWING ITEMS, IN ADDITION TO THOSE REQUIRED BY NFPA 70: 1. FEEDERS AND BRANCH CIRCUITS, 2. LIGHTING CIRCUITS. 3. RECEPTACLE CIRCUITS, 4. SINGLE-PHASE MOTOR AND APPLIANCE BRANCH CIRCUITS, 5. THREE-PHASE MOTOR AND APPLIANCE BRANCH CIRCUITS. 6. FLEXIBLE RACEWAY RUNS. 7. ARMORED AND METAL -CLAD CABLE RUNS, 8. COMPUTER AND RACK -MOUNTED ELECTRONIC EQUIPMENT CIRCUITS: INSTALL INSULATED EQUIPMENT GROUNDING CONDUCTOR IN BRANCH -CIRCUIT RUNS FROM EQUIPMENT -AREA POWER PANELS. C. AIR -DUCT EQUIPMENT CIRCUITS: INSTALL INSULATED EQUIPMENT GROUNDING CO NDUCTOR DUCT -MOUNTED ELECTRICAL DEVICES OP ERATING AT 120 V AND MORE, INCLUDING AIR CLEANERS, HEATERS, DAMPERS, HUMIDIFIERS, AND OTHER DUCT ELECTRICAL EQUIPMENT. BOND CONDUCTOR TO EACH UNIT AND TO AIR DUCT AND CONNECTED METALLIC PIPING. D. SIGNAL AND COMMUNICATION EQUIPMENT: IN ADDITION TO GROUNDING AND BONDING REQUIRED BY NFPA 70, PROVIDE A SEPARATE GROUNDING SYSTEM COMPLYING WITH REQUIREMENTS IN TIA/ATIS J-STD-607-A. 1. FOR TELEPHONE, ALARM, VOICE AND DATA, AND OTHER COMMUNICATION EQUIPMENT, PROVIDE INSULATED GROUNDING CONDUCTOR IN RACEWAY FROM GROUNDING ELECTRODE SYSTEM TO GROUND BUS IN EACH TELECOMMUNICATIONS CLOSET AS INDICATED, BOND CLOSET EQUIPMENT TO CLOSET GROUND BUS WITH MININMUM 4 AWG INSULATED GROUNDING CONDUCTOR. 2. SERVICE AND CENTRAL EQUIPMENT LOCATIONS AND WIRING CLOSETS: TERMINATE GROUNDING CONDUCTOR ON A 1/4-BY-4-BY-12-INCH (6.3-BY-100-BY-300-MM) GROUNDING BUS. 3. TERMINAL CABINETS: TERMINATE GROUNDING CONDUCTOR ON CABINET GROUNDING TERMINAL. 3.3 INSTALLATION A. GROUNDING CONDUCTORS: ROUTE ALONG SHORTEST AND STRAIGHTEST PATHS POSSIBLE UNLESS OTHERWISE INDICATED OR REQUIRED BY CODE. AVOID OBSTRUCTING ACCESS OR PLACING CONDUCTORS WHERE THEY MAY BE SUBJECTED TO STRAIN, IMPACT, OR DAMAGE. B. GROUND BONDING COMMON WITH LIGHTNING PROTECTION SYSTEM: COMPLY WITH NFPA 780 AND UL 96 WHEN INTERCONNECTING WITH LIGHTNING PROTECTION SYSTEM. BOND ELECTRICAL POWER SYSTEM GROUND DIRECTLY TO LIGHTNING PROTECTION SYSTEM GROUNDING CONDUCTOR AT CLOSEST POINT TO ELECTRICAL SERVICE GROUNDING ELECTRODE. USE BONDING CONDUCTOR SIZED SAME AS SYSTEM GROUNDING ELECTRODE CONDUCTOR, AND INSTALL IN CONDUIT. C. GROUND RODS: DRIVE RODS UNTIL TOPS ARE 2 INCHES (50 MM) BELOW FINISHED FLOOR OR FINAL GRADE UNLESS OTHERWISE INDICATED. 1. INTERCONNECT GROUND RODS WITH GROUNDING ELECTRODE CONDUCTOR BELOW GRADE AND AS OTHERWISE INDICATED. MAKE CONNECTIONS WITHOUT EXPOSING STEEL OR DAMAGING COATING IF ANY, 2. FOR GROUNDING ELECTRODE SYSTEM, INSTALL AT LEAST THREE RODS SPACED AT LEAST ONE -ROD LENGTH FROM EACH OTHER AND LOCATED AT LEAST THE SAME DISTANCE FROM OTHER GROUNDING ELECTRODES, AND CONNECT TO THE SERVICE GROUNDING ELECTRODE CONDUCTOR, D. TEST WELLS: GROUND ROD DRIVEN THROUGH DRILLED HOLE IN BOTTOM OF HANDHOLE. HANDHOLES ARE SPECIFIED IN DIVISION 26 SECTION "UNDERGROUND DUCTS AND RACEWAYS FOR ELECTRICAL SYSTEMS," AND SHALL BE AT LEAST 12 INCHES (300 MM) DEEP, WITH COVER. 1. TEST WELLS: INSTALL AT LEAST ONE TEST WELL FOR EACH SERVICE UNLESS OTHERWISE INDICATED. INSTALL AT THE GROUND ROD ELECTRICALLY CLOSEST TO SERVICE ENTRANCE. SET TOP OF TEST WELL FLUSH WITH FINISHED GRADE OR FLOOR. E. BONDING STRAPS AND JUMPERS: INSTALL IN LOCATIONS ACCESSIBLE FOR INSPECTION AND MAINTENANCE EXCEPT WHERE ROUTED THROUGH SHORT LENGTHS OF CONDUIT. 1. BONDING TO STRUCTURE: BOND STRAPS DIRECTLY TO BASIC STRUCTURE, TAKING CARE NOT TO PENETRATE ANY ADJACENT PARTS. 2. BONDING TO EQUIPMENT MOUNTED ON VIBRATION ISOLATION HANGERS AND SUPPORTS: INSTALL BONDING SO VIBRATION IS NOT TRANSMITTED TO RIGIDLY MOUNTED EQUIPMENT. 3. USE EXOTHERMIC -WELDED CONNECTORS FOR OUTDOOR LOCATIONS; IF A DISCONNECT -TYPE CONNECTION IS REQUIRED, USE A BOLTED CLAMP. Sims Wilkerson Cartil Engineering, Inc. 12124 High Tech Avenue - Suite. 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-5900 FL. CERT. OF AUTH. NO. 6106 o GARY A. %7=RS0N, P.E. J3167 o KYLE J. CN MII P.E. 53269 OT ,W S. LEbA'E. F.E. TIDE" o JE:W A R"REhM1I.AN, P E, 65629 NSA 11 R.AERXANDER,P.E. 55422 14001 111. At �0, STATEOp f� Fs _4 0R 10 P`-"+vim //'//j/ 91 0NIA! I l I \`\�� ; � s U � u J U U LLj � ca Lo J 4-0 W W •5) 0 N J LL Z N4-0 "C" o -� • W 0 > 0 F_ U LL. U • 0 C) U a� U U L1� J Q J ^�^ IvJL w V/ T_ v) o_L0 LL N o p w o v V'^J co VJ - = W SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS CONTINUED F. GROUNDING AND BONDING FOR PIPING: 1. METAL WATER SERVICE PIPE: INSTALL INSULATED COPPER GROUNDING CONDUCTORS, IN CONDUIT, FROM BUILDING'S MAIN SERVICE EQUIPMENT, OR GROUNDING BUS, TO MAIN METAL WATER SERVICE ENTRANCES TO BUILDING. CONNECT GROUNDING CONDUCTORS TO MAIN METAL WATER SERVICE PIPES; USE A BOLTED CLAMP CONNECTOR OR BOLT A LUG -TYPE CONNECTOR TO A PIPE FLANGE BY USING ONE OF THE LUG BOLTS OF THE FLANGE. WHERE A DIELECTRIC MAIN WATER FITTING IS INSTALLED, CONNECT GROUNDING CONDUCTOR ON STREET SIDE OF FITTING. BOND METAL GROUNDING CONDUCTOR CONDUIT OR SLEEVE TO CONDUCTOR AT EACH END. 2. WATER METER PIPING: USE BRAIDED -TYPE BONDING JUMPERS TO ELECTRICALLY BYPASS WATER METERS. CONNECT TO PIPE WITH A BOLTED CONNECTOR. 3. BOND EACH ABOVEGROUND PORTION OF GAS PIPING SYSTEM DOWNSTREAM FROM EQUIPMENT SHUTOFF VALVE. G. BONDING INTERIOR METAL DUCTS: BOND METAL AIR DUCTS TO EQUIPMENT GROUNDING CONDUCTORS OF ASSOCIATED FANS, BLOWERS, ELECTRIC HEATERS, AND AIR CLEANERS. INSTALL BONDING JUMPER TO BOND ACROSS FLEXIBLE DUCT CONNECTIONS TO ACHIEVE CONTINUITY. H. GROUND RING: INSTALL AGROUND CONDUCTOR, ELECTRICALLY CONNECTED TO EACH BUILDING STRUCTURE GROUND ROD AND EXTEND AROUND THE PERIMETER OF THE BUILDING. 1. INSTALL TINNED -COPPER CONDUCTOR NOT LESS THAN 210 AWG FOR GROUND RING. 2. BURY GROUND RING NOT LESS THAN 24 INCHES FROM BUILDING FOUNDATION. 1. LIFER GROUND (CONCRETE -ENCASED GROUNDING ELECTRODE): FABRICATE ACCORDING TO NFPA 70; USE A MINIMUM OF 20 FEET (6 M) OF BARE COPPER CONDUCTOR NOT SMALLER THAN NO.4 AWG. 1. IF CONCRETE FOUNDATION IS LESS THAN 20 FEET (6 M) LONG, COIL EXCESS CONDUCTOR WITHIN BASE OF FOUNDATION. 2. BOND GROUNDING CONDUCTOR TO REINFORCING STEEL IN AT LEAST FOUR LOCATIONS AND TO ANCHOR BOLTS. EXTEND GROUNDING CONDUCTOR BELOW GRADE AND CONNECT TO BUILDING'S GROUNDING GRID OR TO GROUNDING ELECTRODE EXTERNAL TO CONCRETE. 3.4 LABELING A. COMPLY WITH REQUIREMENTS IN DIVISION 26 SECTION "IDENTIFICATION FOR ELECTRICAL SYSTEMS" ARTICLE FOR INSTRUCTION SIGNS. THE LABEL OR ITS TEXT SHALL BE GREEN. B. INSTALL LABELS AT THE TELECOMMUNICATIONS BONDING CONDUCTOR AND GROUNDING EQUALIZER AND AT THE GROUNDING ELECTRODE CONDUCTOR Jig 40:1011�b9Ad LABEL TEXT: "IF THIS CONNECTOR OR CABLE IS LOOSE OR IF IT MUST BE REMOVED FOR ANY REASON, NOTIFY THE FACILITY MANAGER." 3.5 FIELD QUALITY CONTROL A. TESTING AGENCY: ENGAGE A QUALIFIED TESTING AGENCY TO PERFORM TESTS AND INSPECTIONS. B. MANUFACTURER'S FIELD SERVICE: ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO INSPECT, TEST, AND ADJUST COMPONENTS, ASSEMBLIES, AND EQUIPMENT INSTALLATIONS, INCLUDING CONNECTIONS. C. PERFORM TESTS AND INSPECTIONS. 1. MANUFACTURER'S FIELD SERVICE: ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO INSPECT COMPONENTS, ASSEMBLIES, AND EQUIPMENT INSTALLATIONS, INCLUDING CONNECTIONS, AND TO ASSIST IN TESTING, D. TESTS AND INSPECTIONS: 1. AFTER INSTALLING GROUNDING SYSTEM BUT BEFORE PERMANENT ELECTRICAL CIRCUITS HAVE BEEN ENERGIZED, TEST FOR COMPLIANCE WITH REQUIREMENTS. 2. INSPECT PHYSICAL AND MECHANICAL CONDITION. VERIFY TIGHTNESS OF ACCESSIBLE, BOLTED, ELECTRICAL CONNECTIONS WITH A CALIBRATED TORQUE WRENCH ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. TEST COMPLETED GROUNDING SYSTEM AT EACH LOCATION WHERE A MAXIMUM GROUND -RESISTANCE LEVEL IS SPECIFIED, AT SERVICE DISCONNECT ENCLOSURE GROUNDING TERMINAL, AT GROUND TEST WELLS, AND AT INDIVIDUAL GROUND RODS. MAKE TESTS AT GROUND RODS BEFORE ANY CONDUCTORS ARE CONNECTED. a. MEASURE GROUND RESISTANCE NO FEWER THAN TWO FULL DAYS AFTER LAST TRACE OF PRECIPITATION AND WITHOUT SOIL BEING MOISTENED BY ANY MEANS OTHER THAN NATURAL DRAINAGE OR SEEPAGE AND WITHOUT CHEMICAL TREATMENT OR OTHER ARTIFICIAL MEANS OF REDUCING NATURAL GROUND RESISTANCE. b. PERFORM TESTS BY FALL -OF -POTENTIAL METHOD ACCORDING TO IEEE 81. 4. PREPARE DIMENSIONED DRAWINGS LOCATING EACH TEST WELL, GROUND ROD AND GROUND -ROD ASSEMBLY, AND OTHER GROUNDING ELECTRODES. IDENTIFY EACH BY LETTER IN ALPHABETICAL ORDER, AND KEY TO THE RECORD OF TESTS AND OBSERVATIONS. INCLUDE THE NUMBER OF RODS DRIVEN AND THEIR DEPTH AT EACH LOCATION, AND INCLUDE OBSERVATIONS OF WEATHER AND OTHER PHENOMENA THAT MAY AFFECT TEST RESULTS. DESCRIBE MEASURES TAKEN TO IMPROVE TEST RESULTS, E. GROUNDING SYSTEM WILL BE CONSIDERED DEFECTIVE IF IT DOES NOT PASS TESTS AND INSPECTIONS. F. PREPARE TEST AND INSPECTION REPORTS, G. REPORT MEASURED GROUND RESISTANCES THAT EXCEED THE FOLLOWING VALUES: 1. POWER AND LIGHTING EQUIPMENT OR SYSTEM WITH CAPACITY OF 500 KVA AND LESS: 10 OHMS. H. EXCESSIVE GROUND RESISTANCE: IF RESISTANCE TO GROUND EXCEEDS SPECIFIED VALUES, NOTIFY ARCHITECT PROMPTLY AND INCLUDE RECOMMENDATIONS TO REDUCE GROUND RESISTANCE. END OF SECTION 260526 SECTION 260529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1-GENERAL 1.1 RELATED DOCUMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. 1.2 SUMMARY A. THIS SECTION INCLUDES THE FOLLOWING: 1. HANGERS AND SUPPORTS FOR ELECTRICAL EQUIPMENT AND SYSTEMS. 2. CONSTRUCTION REQUIREMENTS FOR CONCRETE BASES. 1.3 DEFINITIONS A. EMT: ELECTRICAL METALLIC TUBING. B. IMC: INTERMEDIATE METAL CONDUIT. C. RMC: RIGID METAL CONDUIT. SECTION 260529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS CONTINUED 2.2 FABRICATED METAL EQUIPMENT SUPPORT ASSEMBLIES A. DESCRIPTION: WELDED OR BOLTED, STRUCTURAL -STEEL SHAPES, SHOP OR FIELD FABRICATED TO FIT DIMENSIONS OF SUPPORTED EQUIPMENT. B. MATERIALS: COMPLY WITH REQUIREMENTS IN DIVISION 05 SECTION "METAL FABRICATIONS" FOR STEEL SHAPES AND PLATES. PART 3-EXECUTION 3.1 APPLICATION A. COMPLY WITH NECA 1 AND NECA 101 FOR APPLICATION OF HANGERS AND SUPPORTS FOR ELECTRICAL EQUIPMENT AND SYSTEMS EXCEPT IF REQUIREMENTS IN THIS SECTION ARE STRICTER. B. MAXIMUM SUPPORT SPACING AND MINIMUM HANGER ROD SIZE FOR RACEWAY: SPACE SUPPORTS FOR EMT, IMC, AND RMC AS REQUIRED BY NFPA 70. MINIMUM ROD SIZE SHALL BE 114INCH (6 MM) IN DIAMETER. C. MULTIPLE RACEWAYS OR CABLES: INSTALL TRAPEZE -TYPE SUPPORTS FABRICATED WITH STEEL SLOTTED OR OTHER SUPPORT SYSTEM, SIZED SO CAPACITY CAN BE INCREASED BY AT LEAST 25 PERCENT IN FUTURE WITHOUT EXCEEDING SPECIFIED DESIGN LOAD LIMITS. 1. SECURE RACEWAYS AND CABLES TO THESE SUPPORTS WITH TWO -BOLT CONDUIT CLAMPS. D. SPRING -STEEL CLAMPS DESIGNED FOR SUPPORTING SINGLE CONDUITS WITHOUT BOLTS MAY BE USED FOR 1-1/2-INCH (38-MM) AND SMALLER RACEWAYS SERVING BRANCH CIRCUITS AND COMMUNICATION SYSTEMS ABOVE SUSPENDED CEILINGS AND FOR FASTENING RACEWAYS TO TRAPEZE SUPPORTS. 3.2 SUPPORT INSTALLATION A. COMPLY WITH NECA 1 AND NECA 101 FOR INSTALLATION REQUIREMENTS EXCEPT AS SPECIFIED IN THIS ARTICLE. B. RACEWAY SUPPORT METHODS; IN ADDITION TO METHODS DESCRIBED IN NECA 1, EMT, IMC, AND RMC MAY BE SUPPORTED BY OPENINGS THROUGH STRUCTURE MEMBERS, AS PERMITTED IN NFPA 70. C. STRENGTH OF SUPPORT ASSEMBLIES: WHERE NOT INDICATED, SELECT SIZES OF COMPONENTS SO STRENGTH WILL BE ADEQUATE TO CARRY PRESENT AND FUTURE STATIC LOADS WITHIN SPECIFIED LOADING LIMITS, MINIMUM STATIC DESIGN LOAD USED FOR STRENGTH DETERMINATION SHALL BE WEIGHT OF SUPPORTED COMPONENTS PLUS 200 LB (90 KG). D. MOUNTING AND ANCHORAGE OF SURFACE -MOUNTED EQUIPMENT AND COMPONENTS: ANCHOR AND FASTEN ELECTRICAL ITEMS AND THEIR SUPPORTS TO BUILDING STRUCTURAL ELEMENTS BY THE FOLLOWING METHODS UNLESS OTHERWISE INDICATED BY CODE: 1. TO WOOD: FASTEN WITH LAG SCREWS OR THROUGH BOLTS. 2. TO NEW CONCRETE: BOLT TO CONCRETE INSERTS. 3. TO MASONRY: APPROVED TOGGLE -TYPE BOLTS ON HOLLOW MASONRY UNITS AND EXPANSION ANCHOR FASTENERS ON SOLID MASONRY UNITS. 4. INSTEAD OF EXPANSION ANCHORS, POWDER -ACTUATED DRIVEN THREADED STUDS PROVIDED WITH LOCK WASHERS AND NUTS MAY BE USED IN EXISTING STANDARD -WEIGHT CONCRETE 41NCHES (100 MM) THICK OR GREATER. DO NOT USE FOR ANCHORAGE TO LIGHTWEIGHT -AGGREGATE CONCRETE OR FOR SLABS LESS THAN 4 INCHES (100 MM) THICK. 5. TO STEEL: WELDED THREADED STUDS COMPLYING WITH AWS D1.1/DlAM, WITH LOCK WASHERS AND NUTS. 6. TO LIGHT STEEL: SHEET METAL SCREWS. 7. ITEMS MOUNTED ON HOLLOW WALLS AND NONSTRUCTURAL BUILDING SURFACES: MOUNT CABINETS, PANELBOARDS, DISCONNECT SWITCHES, CONTROL ENCLOSURES, PULL AND JUNCTION BOXES, TRANSFORMERS, AND OTHER DEVICES ON SLOTTED -CHANNEL RACKS ATTACHED TO SUBSTRATE. E. DRILL HOLES FOR EXPANSION ANCHORS IN CONCRETE AT LOCATIONS AND TO DEPTHS THAT AVOID REINFORCING BARS. 3.3 INSTALLATION OF FABRICATED METAL SUPPORTS A. COMPLY WITH INSTALLATION REQUIREMENTS IN DIVISION 05 SECTION "METAL FABRICATIONS" FOR SITE -FABRICATED METAL SUPPORTS. B. CUT, FIT, AND PLACE MISCELLANEOUS METAL SUPPORTS ACCURATELY IN LOCATION, ALIGNMENT, AND ELEVATION TO SUPPORTAND ANCHOR ELECTRICAL MATERIALS AND EQUIPMENT. C. FIELD WELDING: COMPLY WITH AWS D1.1/D1.1 M. 3.4 CONCRETE BASES A. CONSTRUCT CONCRETE BASES OF DIMENSIONS INDICATED BUT NOT LESS THAN 41NCHES (100 MM) LARGER IN BOTH DIRECTIONS THAN SUPPORTED UNIT, AND SO ANCHORS WILL BE A MINIMUM OF 10 BOLT DIAMETERS FROM EDGE OF THE BASE, B. USE 3000-PSI (20.7-MPA), 28-DAY COMPRESSIVE -STRENGTH CONCRETE. CONCRETE MATERIALS, REINFORCEMENT, AND PLACEMENT REQUIREMENTS ARE SPECIFIED IN DIVISION 03 SECTION "CAST -IN -PLACE CONCRETE." C. ANCHOR EQUIPMENT TO CONCRETE BASE. 1. PLACE AND SECURE ANCHORAGE DEVICES. USE SUPPORTED EQUIPMENT MANUFACTURER'S SETTING DRAWINGS, TEMPLATES, DIAGRAMS, INSTRUCTIONS, AND DIRECTIONS FURNISHED WITH ITEMS TO BE EMBEDDED. 2. INSTALL ANCHOR BOLTS TO ELEVATIONS REQUIRED FOR PROPER ATTACHMENT TO SUPPORTED EQUIPMENT. 3. INSTALL ANCHOR BOLTS ACCORDING TO ANCHOR -BOLT MANUFACTURER'S WRITTEN INSTRUCTIONS. 3.5 PAINTING A. TOUCHUP: CLEAN FIELD WELDS AND ABRADED AREAS OF SHOP PAINT. PAINT EXPOSED AREAS IMMEDIATELY AFTER ERECTING HANGERS AND SUPPORTS. USE SAME MATERIALS AS USED FOR SHOP PAINTING, COMPLY WITH SSPC-PA 1 REQUIREMENTS FOR TOUCHING UP FIELD -PAINTED SURFACES. 1. APPLY PAINT BY BRUSH OR SPRAY TO PROVIDE MINIMUM DRY FILM THICKNESS OF 2.0 MILS (0.05 MM). B. TOUCHUP: COMPLY WITH REQUIREMENTS IN DIVISION 09 PAINTING SECTIONS FOR CLEANING AND TOUCHUP PAINTING OF FIELD WELDS, BOLTED CONNECTIONS, AND ABRADED AREAS OF SHOP PAINT ON MISCELLANEOUS METAL. C. GALVANIZED SURFACES: CLEAN WELDS, BOLTED CONNECTIONS, AND ABRADED AREAS AND APPLY GALVANIZING -REPAIR PAINT TO COMPLY WITH ASTM A 780. END OF SECTION 260529 SECTION 260533 - RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. 1.4 PERFORMANCE REQUIREMENTS A. DELEGATED DESIGN: DESIGN SUPPORTS FOR MULTIPLE RACEWAYS, INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS BY A QUALIFIED 1.2 SUMMARY PROFESSIONAL ENGINEER, USING PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED. A. SECTION INCLUDES: B. DESIGN SUPPORTS FOR MULTIPLE RACEWAYS CAPABLE OF SUPPORTING COMBINED WEIGHT OF SUPPORTED SYSTEMS AND ITS CONTENTS. 1. METAL CONDUITS, TUBING, AND FITTINGS, C. DESIGN EQUIPMENT SUPPORTS CAPABLE OF SUPPORTING COMBINED OPERATING WEIGHT OF SUPPORTED EQUIPMENT AND CONNECTED SYSTEMS AND 2. NONMETAL CONDUITS, TUBING, AND FITTINGS. COMPONENTS, 3. METAL WIREWAYS AND AUXILIARY GUTTERS. D. RATED STRENGTH: ADEQUATE IN TENSION, SHEAR, AND PULLOUT FORCE TO RESIST MAXIMUM LOADS CALCULATED OR IMPOSED FOR THIS PROJECT, 4. NONMETAL WIREWAYS AND AUXILIARY GUTTERS. WITH A MINIMUM STRUCTURAL SAFETY FACTOR OF FIVE TIMES THE APPLIED FORCE. 5. SURFACE RACEWAYS. 6. BOXES AND ENCLOSURES 1.5 ACTION SUBMITTALS A. PRODUCT DATA: FOR THE FOLLOWING: 1.3 DEFINITIONS 1. STEEL SLOTTED SUPPORT SYSTEMS, A. GRC: GALVANIZED RIGID STEEL CONDUIT. 2. NONMETALLIC SLOTTED SUPPORT SYSTEMS. B. IMC: INTERMEDIATE METAL CONDUIT. 1.6 QUALITY ASSURANCE A. COMPLY WITH NFPA 70. 1.7 COORDINATION A. COORDINATE SIZE AND LOCATION OF CONCRETE BASES. CAST ANCHOR -BOLT INSERTS INTO BASES, CONCRETE, REINFORCEMENT, AND FORMWORK REQUIREMENTS ARE SPECIFIED IN DIVISION 03. PART2-PRODUCTS 2.1 SUPPORT,ANCHORAGE, AND ATTACHMENT COMPONENTS A. STEEL SLOTTED SUPPORT SYSTEMS: COMPLY WITH MFMA-4, FACTORY -FABRICATED COMPONENTS FOR FIELD ASSEMBLY. 1. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: a. ALLIED TUBE & CONDUIT. b. COOPER B-LINE, INC.; A DIVISION OF COOPER INDUSTRIES. C. ERICO INTERNATIONAL CORPORATION. d. GS METALS CORP. e. THOMAS & BETTS CORPORATION. f. UNISTRUT; TYCO INTERNATIONAL, LTD. 9. WESANCO, INC. 2. PAINTED COATINGS: MANUFACTURER'S STANDARD PAINTED COATING APPLIED ACC ORDING TO MFMA-4. 3. CHANNEL DIMENSIONS: SELECTED FOR APPLICABLE LOAD CRITERIA. B. RACEWAY AND CABLE SUPPORTS: AS DESCRIBED IN NECA 1 AND NECA 101. C. CONDUIT AND CABLE SUPPORT DEVICES: STEEL AND MALLEABLE -IRON HANGERS, CLAMPS, AND ASSOCIATED FITTINGS, DESIGNED FOR TYPES AND SIZES OF RACEWAY OR CABLE TO BE SUPPORTED. D. SUPPORT FOR CONDUCTORS IN VERTICAL CONDUIT: FACTORY -FABRICATED ASSEMBLY CONSISTING OF THREADED BODY AND INSULATING WEDGING PLUG OR PLUGS FOR NON -ARMORED ELECTRICAL CONDUCTORS OR CABLES IN RISER CONDUITS. PLUGS SHALL HAVE NUMBER, SIZE, AND SHAPE OF CONDUCTOR GRIPPING PIECES AS REQUIRED TO SUIT INDIVIDUAL CONDUCTORS OR CABLES SUPPORTED. BODY SHALL BE MALLEABLE IRON. E. STRUCTURAL STEEL FOR FABRICATED SUPPORTS AND RESTRAINTS: ASTM A 36/A 36M, STEEL PLATES, SHAPES, AND BARS; BLACK AND GALVANIZED. F. MOUNTING, ANCHORING, AND ATTACHMENT COMPONENTS: ITEMS FOR FASTENING ELECTRICAL ITEMS OR THEIR SUPPORTS TO BUILDING SURFACES INCLUDE THE FOLLOWING: 1. POWDER -ACTUATED FASTENERS: THREADED -STEEL STUD, FOR USE IN HARDENED PORTLAND CEMENT CONCRETE, STEEL, OR WOOD, WITH TENSION, SHEAR, AND PULLOUT CAPACITIES APPROPRIATE FOR SUPPORTED LOADS AND BUILDING MATERIALS WHERE USED. a. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1) HILTI INC. 2) ITW RAMSET/RED HEAD; A DIVISION OF ILLINOIS TOOL WORKS, INC. 3) MKT FASTENING,LLC. 4) SIMPSON STRONG -TIE CO., INC.; MASTERSET FASTENING SYSTEMS UNIT, Z MECHANICAL -EXPANSION ANCHORS: INSERT -WEDGE -TYPE, ZINC -COATED STEEL, FOR USE IN HARDENED PORTLAND CEMENT CONCRETE WITH TENSION, SHEAR, AND PULLOUT CAPACITIES APPROPRIATE FOR SUPPORTED LOADS AND BUILDING MATERIALS IN WHICH USED. a. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1) COOPER B-LINE, INC.; A DIVISION OF COOPER INDUSTRIES, 2) EMPIRE TOOL AND MANUFACTURING CO., INC. 3) HILTI INC. 4) ITW RAMSET/RED HEAD; A DIVISION OF ILLINOIS TOOL WORKS, INC. 5) MKT FASTENING, LLC. 3. CONCRETE INSERTS: STEEL OR MALLEABLE -IRON, SLOTTED SUPPORT SYSTEM UNITS SIMILAR TO MSS TYPE 18; COMPLYING WITH MFMA-4 OR MSS SP-58. 4. CLAMPS FOR ATTACHMENT TO STEEL STRUCTURAL ELEMENTS: MSS SP-58, TYPE SUITABLE FOR ATTACHED STRUCTURAL ELEMENT. 5. THROUGH BOLTS: STRUCTURAL TYPE, HEX HEAD, AND HIGH STRENGTH. COMPLY WITH ASTM A 325. 6. TOGGLE BOLTS: ALL -STEEL SPRINGHEAD TYPE. 7. HANGER RODS: THREADED STEEL. 1.4 ACTION SUBMITTALS A. PRODUCT DATA: FOR SURFACE RACEWAYS, WIREWAYS AND FITTINGS, HINGED -COVER ENCLOSURES. 1.5 INFORMATIONAL SUBMITTALS A. SOURCE QUALITY -CONTROL REPORTS. PART2-PRODUCTS 2.1 METAL CONDUITS, TUBING, AND FITTINGS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. AFC CABLE SYSTEMS, INC. 2. ALLIED TUBE & CONDUIT; A TYCO INTERNATIONAL LTD. CO. 3. ANAMET ELECTRICAL, INC. 4. ELECTRI-FLEX COMPANY. 5. 0-ZIGEDNEY; A BRAND OF EGS ELECTRICAL GROUP. 6. PICOMA INDUSTRIES, A SUBSIDIARY OF MUELLER WATER PRODUCTS, INC. 7. REPUBLIC CONDUIT. 8. ROBROY INDUSTRIES. 9. SOUTHWIRE COMPANY. 10. THOMAS & BETTS CORPORATION. 11. WESTERN TUBE AND CONDUIT CORPORATION. 12. WHEATLAND TUBE COMPANY A DIVISION OF JOHN MANEELY COMPANY. B. LISTING AND LABELING: METAL CONDUITS, TUBING, AND FITTINGS SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70, BY QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. C. GRC: COMPLY WITH ANSI C80.1 AND UL 6. D. IMC: COMPLY WITH ANSI C80.6 AND UL 1242. E. PVC -COATED STEEL CONDUIT: PVC -COATED RIGID STEEL CONDUIT OR IMC. 1. COMPLY WITH NEMA RN 1. 2. COATING THICKNESS: 0.040 INCH (1 MM), MINIMUM. F. EMT: COMPLY WITH ANSI C80.3 AND UL 797. G. FMC: COMPLY WITH UL 1; ZINC -COATED STEEL FLEXIBLE STEEL CONDUIT H. LFMC WITH PVC JACKET AND COMPLYING WITH UL 360. FITTINGS FOR METAL CONDUIT: COMPLY WITH NEMA FB 1 AND UL 514B. I. TT GS 0 COM Y 1. FITTINGS FOR EMT: a. MATERIAL: STEEL OR DIE CAST ET SCREW OR COMPRESSION. b TYPE: S 2. EXPANSION FITTINGS: PVC OR STEEL TO MATCH CONDUIT TYPE, COMPLYING WITH UL 651, RATED FOR ENVIRONMENTAL CONDITIONS WHERE INSTALLED, AND INCLUDING FLEXIBLE EXTERNAL BONDING JUMPER. 3. COATING FOR FITTINGS FOR PVC -COATED CONDUIT: MINIMUM THICKNESS OF 0.040INCH (1 MM), WITH OVERLAPPING SLEEVES PROTECTING THREADED JOINTS. J. JOINT COMPOUND FOR IMC OR GRC: APPROVED, AS DEFINED IN NFPA 70, BY AUTHORITIES HAVING JURISDICTION FOR USE IN CONDUIT ASSEMBLIES, AND COMPOUNDED FOR USE TO LUBRICATE AND PROTECT THREADED CONDUIT JOINTS FROM CORROSION AND TO ENHANCE THEIR CONDUCTIVITY. SECTION 260533 - RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS CONTINUED 2.2 NONMETALLIC CONDUITS, TUBING, AND FITTINGS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. AFC CABLE SYSTEMS, INC. 2. ANAMET ELECTRICAL, INC. 3. ARNCO CORPORATION. 4. CANTEX INC. 5. CERTAINTEED CORP. 6. CONDUX INTERNATIONAL, INC. 7. ELECTRI-FLEX COMPANY. 8. KRALOY. 9. LAMSON & SESSIONS; CARLON ELECTRICAL PRODUCTS. 10. NIEDAX-KLEINHUIS USA, INC. 11. RACO; A HUBBELL COMPANY. 12, THOMAS & BETTS CORPORATION. B. LISTING AND LABELING: NONMETALLIC CONDUITS, TUBING, AND FITTINGS SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. C. ENT: COMPLY WITH NEMA TC 13 AND UL 1653, D. RNC: TYPE EPC-40-PVC, COMPLYING WITH NEMA TC 2 AND UL 651 UNLESS OTHERWISE INDICATED. E. LFNC: COMPLY WITH UL 1660. F. RIGID HOPE: COMPLY WITH UL 651A. G. CONTINUOUS HDPE: COMPLY WITH UL 651 B. H. COILABLE HDPE: PREASSEMBLED WITH CONDUCTORS OR CABLES, AND COMPLYING WITH ASTM D 3485. I. RTRC: COMPLY WITH UL 1684A AND NEMA TC 14. J. FITTINGS FOR ENT AND RNC: COMPLY WITH NEMA TC 3; MATCH TO CONDUIT OR TUBING TYPE AND MATERIAL. K. FITTINGS FOR LFNC: COMPLY WITH UL 514B. 2.3 METAL WIREWAYS AND AUXILIARY GUTTERS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. COOPER B-LINE, INC. 2. HOFFMAN; A PENTAIR COMPANY. 3. MONO -SYSTEMS, INC. 4. SQUARE D; A BRAND OF SCHNEIDER ELECTRIC. B. DESCRIPTION: SHEET METAL, COMPLYING WITH UL 870 AND NEMA 250, TYPE 1 FOR INTERIOR APPLICATIONS AND TYPE 3R FOR EXTERIOR APPLICATIONS UNLESS OTHERWISE INDICATED, AND SIZED ACCORDING TO NFPA 70. IN NFPA 70 BY A QUALIFIED AGENCY, AND MARKED FOR 1. METAL WIREWAYS INSTALLED OUTDOORS SHALL BE LISTED AND LABELED AS DEFINEDQ ED TESTING INTENDED LOCATION AND APPLICATION. C. FITTINGS AND ACCESSORIES: INCLUDE COVERS, COUPLINGS, OFFSETS, ELBOWS, EXPANSION JOINTS, ADAPTERS, HOLD-DOWN STRAPS, END CAPS, AND OTHER FITTINGS TO MATCH AND MATE WITH WIREWAYS AS REQUIRED FOR COMPLETE SYSTEM. D. WIREWAY COVERS: HINGED AND GASKETED TYPE UNLESS OTHERWISE INDICATED, E. FINISH: MANUFACTURER'S STANDARD ENAMEL FINISH. 2.4 NONMETALLIC WIREWAYS AND AUXILIARY GUTTERS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. ALLIED MOULDED PRODUCTS, INC. 2. HOFFMAN; A PENTAIR COMPANY. 3. LAMSON & SESSIONS; CARLON ELECTRICAL PRODUCTS. 4. NIEDAX-KLEINHUIS USA, INC. B. LISTING AND LABELING: NONMETALLIC WIREWAYS AND AUXILIARY GUTTERS SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. C. DESCRIPTION: FIBERGLASS POLYESTER, EXTRUDED AND FABRICATED TO REQUIRED SIZE AND SHAPE, WITHOUT HOLES OR KNOCKOUTS, COVER SHALL BE GASKETED WITH OIL -RESISTANT GASKET MATERIAL AND FASTENED WITH CAPTIVE SCREWS TREATED FOR CORROSION RESISTANCE, CONNECTIONS SHALL BE FLANGED AND HAVE STAINLESS -STEEL SCREWS AND OIL -RESISTANT GASKETS, D. DESCRIPTION: PVC, EXTRUDED AND FABRICATED TO REQUIRED SIZE AND SHAPE, AND HAVING SNAP -ON COVER, MECHANICALLY COUPLED CONNECTIONS, AND PLASTIC FASTENERS. E. FITTINGS AND ACCESSORIES: COUPLINGS, OFFSETS, ELBOWS, EXPANSION JOINTS, ADAPTERS, HOLD-DOWN STRAPS, END CAPS, AND OTHER FITTINGS SHALL MATCH AND MATE WITH WIREWAYS AS REQUIRED FOR COMPLETE SYSTEM, 2.5 BOXES, ENCLOSURES, AND CABINETS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. ADALET. 2. COOPER TECHNOLOGIES COMPANY; COOPER CROUSE-HINDS, 3. EGS/APPLETON ELECTRIC. 4. ERICKSON ELECTRICAL EQUIPMENT COMPANY. 5. FSR INC. 6. HOFFMAN; A PENTAIR COMPANY. 7. HUBBELL INCORPORATED; KILLARK DIVISION. 8. KRALOY. 9. MILBANK MANUFACTURING CO. 10. MONO -SYSTEMS, INC. 11. 0-Z/GEDNEY; A BRAND OF EGS ELECTRICAL GROUP. 12. RACO; A HUBBELL COMPANY. 13. ROBROY INDUSTRIES. 14. SPRING CITY ELECTRICAL MANUFACTURING COMPANY, 15. STAHLIN NON-METALLIC ENCLOSURES; A DIVISION OF ROBROY INDUSTRIES. 16. THOMAS & BETTS CORPORATION. 17. WIREMOLD/LEGRAND. B. GENERAL REQUIREMENTS FOR BOXES AND ENCLOSURES: BOXES AND ENCLOSURES INSTALLED IN WET LOCATIONS SHALL BE LISTED FOR USE IN WET LOCATIONS. C. SHEET METAL OUTLET AND DEVICE BOXES: COMPLY WITH NEMA OS 1 AND UL 514A. D. CAST -METAL OUTLET AND DEVICE BOXES: COMPLY WITH NEMA FB 1, ALUMINUM, TYPE FD, WITH GASKETED COVER. E. NONMETALLIC OUTLET AND DEVICE BOXES: COMPLY WITH NEMA OS 2 AND UL 514C. F. LUMINAIRE OUTLET BOXES: NONADJUSTABLE, DESIGNED FOR ATTACHMENT OF LUMINAIRE WEIGHING 50 LB (23 KG). OUTLET BOXES DESIGNED FOR ATTACHMENT OF LUMINAIRES WEIGHING MORE THAN 50 LB (23 KG) SHALL BE LISTED AND MARKED FOR THE MAXIMUM ALLOWABLE WEIGHT. G. SMALL SHEET METAL PULL AND JUNCTION BOXES: NEMA OS 1. H. CAST -METAL ACCESS, PULL, AND JUNCTION BOXES: COMPLY WITH NEMA FB 1 AND UL 1773, CAST ALUMINUM WITH GASKETED COVER. I. BOX EXTENSIONS USED TO ACCOMMODATE NEW BUILDING FINISHES SHALL BE OF SAME MATERIAL AS RECESSED BOX, J. DEVICE BOX DIMENSIONS: 41NCHES SQUARE BY 2-1/8 INCHES DEEP (100 MM SQUARE BY 60 MM DEEP). K. GANGABLE BOXES ARE ALLOWED. PART 3 - EXECUTION 3.1 RACEWAY APPLICATION A. OUTDOORS: APPLY RACEWAY PRODUCTS AS SPECIFIED BELOW UNLESS OTHERWISE INDICATED: 1. EXPOSED CONDUIT: GRC OR RNC, TYPE EPC-80-PVC. 2. CONCEALED CONDUIT, ABOVEGROUND: GRC OR RNC, TYPE EPC-40-PVC. 3. UNDERGROUND CONDUIT: RNC, TYPE EPC-80-PVC, DIRECT BURIED, 4. CONNECTION TO VIBRATING EQUIPMENT (INCLUDING TRANSFORMERS AND HYDRAULIC, PNEUMATIC, ELECTRIC SOLENOID, OR MOTOR -DRIVEN EQUIPMENT): LFMC 5. BOXES AND ENCLOSURES, ABOVEGROUND: NEMA 250, TYPE 3R. B. INDOORS: APPLY RACEWAY PRODUCTS AS SPECIFIED BELOW UNLESS OTHERWISE INDICATED: 1. EXPOSED, NOT SUBJECT TO PHYSICAL DAMAGE: EMT OR RNC. 2. EXPOSED, NOT SUBJECT TO SEVERE PHYSICAL DAMAGE: EMT OR RNC IDENTIFIED FOR SUCH USE. 3. EXPOSED AND SUBJECT TO SEVERE PHYSICAL DAMAGE: GRC. RACEWAY LOCATIONS INCLUDE THE FOLLOWING; a. LOADING DOCK. b. CORRIDORS USED FOR TRAFFIC OF MECHANIZED CARTS, FORKLIFTS, AND PALLET -HANDLING UNITS. G. MECHANICAL ROOMS. 4. CONCEALED IN CEILINGS AND INTERIOR WALLS AND PARTITIONS: EMT OR RNC, TYPE EPC-40-PVC. 5. CONNECTION TO VIBRATING EQUIPMENT (INCLUDING TRANSFORMERS AND HYDRAULIC, PNEUMATIC, ELECTRIC SOLENOID, OR MOTOR -DRIVEN EQUIPMENT): FMC, EXCEPT USE LFMC IN DAMP OR WET LOCATIONS. 6. DAMP OR WET LOCATIONS: GRC. 7. BOXES AND ENCLOSURES: NEMA 250, TYPE 1, EXCEPT USE NEMA 250, TYPE 4 STAINLESS STEEL IN KITCHENS AND DAMP OR WET LOCATIONS. C. MINIMUM RACEWAY SIZE: 314-INCH (21-MM) TRADE SIZE. D. RACEWAY FITTINGS: COMPATIBLE WITH RACEWAYS AND SUITABLE FOR USE AND LOCATION. 1. RIGID AND INTERMEDIATE STEEL CONDUIT: USE THREADED RIGID STEEL CONDUIT FITTINGS UNLESS OTHERWISE INDICATED. COMPLY WITH NEMA FB 2,10. 2. PVC EXTERNALLY COATED, RIGID STEEL CONDUITS: USE ONLY FITTINGS LISTED FOR USE WITH THIS TYPE OF CONDUIT, PATCH AND SEAL ALL JOINTS, NICKS, AND SCRAPES IN PVC COATING AFTER INSTALLING CONDUITS AND FITTINGS. USE SEALANT RECOMMENDED BY FITTING MANUFACTURER AND APPLY IN THICKNESS AND NUMBER OF COATS RECOMMENDED BY MANUFACTURER. 3. EMT: USE SETSCREW OR COMPRESSION, FITTINGS. COMPLY WITH NEMA FB 2.10. 4. FLEXIBLE CONDUIT: USE ONLY FITTINGS LISTED FOR USE WITH FLEXIBLE CONDUIT. COMPLY WITH NEMA FB 2.20. E. DO NOT INSTALL ALUMINUM CONDUITS, BOXES, OR FITTINGS IN CONTACT WITH CONCRETE OR EARTH. F. INSTALL SURFACE RACEWAYS ONLY WHERE INDICATED ON DRAWINGS, G. DO NOT INSTALL NONMETALLIC CONDUIT WHERE AMBIENT TEMPERATURE EXCEEDS 120 DEG F (49 DEG C). 3.2 INSTALLATION A. COMPLY WITH NECA 1 AND NECA 101 FOR INSTALLATION REQUIREMENTS EXCEPT WHERE REQUIREMENTS ON DRAWINGS OR IN THIS ARTICLE ARE STRICTER. COMPLY WITH NECA 102 FOR ALUMINUM CONDUITS. COMPLY WITH NFPA 70 LIMITATIONS FOR TYPES OF RACEWAYS ALLOWED IN SPECIFIC OCCUPANCIES AND NUMBER OF FLOORS. B. KEEP RACEWAYS AT LEAST 6 INCHES (150 MM) AWAY FROM PARALLEL RUNS OF FLUES AND STEAM OR HOT-WATER PIPES. INSTALL HORIZONTAL RACEWAY RUNS ABOVE WATER AND STEAM PIPING. C. COMPLETE RACEWAY INSTALLATION BEFORE STARTING CONDUCTOR INSTALLATION, D. COMPLY WITH REQUIREMENTS IN DIVISION 26 SECTION "HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS" FOR HANGERS AND SUPPORTS. E. STUB -UPS 0 ARRANG ES CURVED PORTIONS OF BENDS ARE NOT VISIBLE ABOVE FINISHED SLAB. F. INSTALL NO MORE THAN THE EQUIVALENT OF THREE 90-DEGREE BENDS IN ANY CONDUIT RUN EXCEPT FOR CONTROL WIRING CONDUITS, FOR WHICH FEWER BENDS ARE ALLOWED. SUPPORT WITHIN 12 INCHES (300 MM) OF CHANGES IN DIRECTION. G. CONCEAL CONDUIT AND EMT WITHIN FINISHED WALLS, CEILINGS, AND FLOORS UNLESS OTHERWISE INDICATED, INSTALL CONDUITS PARALLEL OR PERPENDICULAR TO BUILDING LINES. H. A. SUPPORT CONDUIT WITHIN 12 INCHES (300 MM) OF ENCLOSURES TO WHICH ATTACHED. I. RACEWAYS EMBEDDED IN SLABS: 1. DO NOT RUN RACEWAYS IN SLAB, Sims Wilkerson Cartier Engineering, Inc. 12124 High Tech Avenue - Suite. 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-5900 FL. CERT, OF AUTH. NO. 6106 o GaY A. W=RSON, RE, 43167 a 3-RLE J. C.4 =R, RE 53269 O M,MS. UV E, P.E. 77010 o MF A. F:IR LAN. RE. 65629 • SMJ Tl. R, ALE.\ANDER, P.E. 55422 14001 ���'\Vg. ALE//// N4 2 1 0'�, , ' STATE OF ; to �iO�E` 70NAt 0/J1111111\O > J L.i�. C v CIOL1J t+ .0 L Irl- LJ L_ 0) O O (N \ `^ VJ O LL -J o z .� o +; \ ® w s ® > O F_ U C o C LL_ C LL U U W J LL J Q J CL \ Q/ �C'l- ^ �`i/-)� T/ /�-/-fir O_� LL04 o Uj M N D CD vA, U) L SECTION 260533- RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS CONTINUED J. STUB -UPS TO ABOVE RECESSED CEILINGS: 1. USE EMT, IMC, OR RMC FOR RACEWAYS. 2. USE A CONDUIT BUSHING OR INSULATED FITTING TO TERMINATE STUB -UPS NOT TERMINATED IN HUBS OR IN AN ENCLOSURE. K. THREADED CONDUIT JOINTS, EXPOSED TO WET, DAMP, CORROSIVE, OR OUTDOOR CONDITIONS: APPLY LISTED COMPOUND TO THREADS OF RACEWAY AND FITTINGS BEFORE MAKING UP JOINTS. FOLLOW COMPOUND MANUFACTURER'S WRITTEN INSTRUCTIONS. L. COAT FIELD -CUT THREADS ON PVC -COATED RACEWAY WITH A CORROSION -PREVENTING CONDUCTIVE COMPOUND PRIOR TO ASSEMBLY. M. RACEWAY TERMINATIONS AT LOCATIONS SUBJECT TO MOISTURE OR VIBRATION: USE INSULATING BUSHINGS TO PROTECT CONDUCTORS INCLUDING CONDUCTORS SMALLER THAN NO.4 AWG. N. TERMINATE THREADED CONDUITS INTO THREADED HUBS OR WITH LOCKNUTS ON INSIDE AND OUTSIDE OF BOXES. INSTALL BUSHINGS ON CONDUITS UP TO 1-1/4-INCH (35MM) TRADE SIZE AND INSULATED THROAT METAL BUSHINGS ON 1-1/2-INCH (41-MM) TRADE SIZE AND LARGER CONDUITS TERMINATED WITH LOCKNUTS. INSTALL INSULATED THROAT METAL GROUNDING BUSHINGS ON SERVICE CONDUITS. 0. INSTALL RACEWAYS SQUARE TO THE ENCLOSURE AND TERMINATE AT ENCLOSURES WITH LOCKNUTS. INSTALL LOCKNUTS HAND TIGHT PLUS 1/4 TURN MORE. P. DO NOT RELY ON LOCKNUTS TO PENETRATE NONCONDUCTIVE COATINGS ON ENCLOSURES. REMOVE COATINGS IN THE LOCKNUT AREA PRIOR TO ASSEMBLING CONDUIT TO ENCLOSURE TO ASSURE A CONTINUOUS GROUND PATH. Q. CUT CONDUIT PERPENDICULAR TO THE LENGTH. FOR CONDUITS2-INCH (53-MM) TRADE SIZE AND LARGER, USE ROLL CUTTER OR A GUIDE TO MAKE CUT STRAIGHT AND PERPENDICULAR TO THE LENGTH, R. INSTALL PULL WIRES IN EMPTY RACEWAYS. USE POLYPROPYLENE OR MONOFILAMENT PLASTIC LINE WITH NOT LESS THAN 200-LB (90-KG) TENSILE STRENGTH. LEAVE AT LEAST 12 INCHES (300 MM) OF SLACK AT EACH END OF PULL WIRE, CAP UNDERGROUND RACEWAYS DESIGNATED AS SPARE ABOVE GRADE ALONGSIDE RACEWAYS IN USE. S. INSTALL RACEWAY SEALING FITTINGS AT ACCESSIBLE LOCATIONS ACCORDING TO NFPA 70 AND FILL THEM WITH LISTED SEALING COMPOUND. FOR CONCEALED RACEWAYS, INSTALL EACH FITTING IN A FLUSH STEEL BOX WITH A BLANK COVER PLATE HAVING A FINISH SIMILAR TO THAT OF ADJACENT PLATES OR SURFACES. INSTALL RACEWAY SEALING FITTINGS ACCORDING TO NFPA 70. T. INSTALL DEVICES TO SEAL RACEWAY INTERIORS AT ACCESSIBLE LOCATIONS, LOCATE SEALS SO NO FITTINGS OR BOXES ARE BETWEEN THE SEAL AND THE FOLLOWING CHANGES OF ENVIRONMENTS. SEAL THE INTERIOR OF ALL RACEWAYS AT THE FOLLOWING POINTS: 1. WHERE CONDUITS PASS FROM WARM TO COLD LOCATIONS, SUCH AS BOUNDARIES OF REFRIGERATED SPACES. 2. WHERE AN UNDERGROUND SERVICE RACEWAY ENTERS A BUILDING OR STRUCTURE. 3. WHERE OTHERWISE REQUIRED BY NFPA 70. U. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SOLVENT WELDING RNC AND FITTINGS. V. FLEXIBLE CONDUIT CONNECTIONS: COMPLY WITH NEMA RV 3. USE A MAXIMUM OF 72 INCHES (1830 MM) OF FLEXIBLE CONDUIT FOR RECESSED AND SEMIRECESSED LUMINAIRES, EQUIPMENT SUBJECT TO VIBRATION, NOISE TRANSMISSION, OR MOVEMENT; AND FOR TRANSFORMERS AND MOTORS. 1. USE LFMC IN DAMP OR WET LOCATIONS SUBJECT TO SEVERE PHYSICAL DAMAGE. 2. USE LFMC OR LFNC IN DAMP OR WET LOCATIONS NOT SUBJECT TO SEVERE PHYSICAL DAMAGE. W. MOUNT BOXES AT HEIGHTS INDICATED ON DRAWINGS. IF MOUNTING HEIGHTS OF BOXES ARE NOT INDIVIDUALLY INDICATED, GIVE PRIORITY TO ADA REQUIREMENTS. INSTALL BOXES WITH HEIGHT MEASURED TO BOTTOM OF BOX UNLESS OTHERWISE INDICATED. X. HORIZONTALLY SEPARATE BOXES MOUNTED ON OPPOSITE SIDES OF WALLS SO THEY ARE NOT IN THE SAME VERTICAL CHANNEL. Y. LOCATE BOXES SO THAT COVER OR PLATE WILL NOT SPAN DIFFERENT BUILDING FINISHES. Z. SUPPORT BOXES OF THREE GANGS OR MORE FROM MORE THAN ONE SIDE BY SPANNING TWO FRAMING MEMBERS OR MOUNTING ON BRACKETS SPECIFICALLY DESIGNED FOR THE PURPOSE. AA. FASTEN JUNCTION AND PULL BOXES TO OR SUPPORT FROM BUILDING STRUCTURE. DO NOT SUPPORT BOXES BY CONDUITS. 3.3 INSTALLATION OF UNDERGROUND CONDUIT A. DIRECT -BURIED CONDUIT: 1. EXCAVATE TRENCH BOTTOM TO PROVIDE FIRM AND UNIFORM SUPPORT FOR CONDUIT. PREPARE TRENCH BOTTOM AS SPECIFIED IN DIVISION 31 SECTION "EARTH MOVING" FOR PIPE LESS THAN 6 INCHES (150 MM) IN NOMINAL DIAMETER. 2. INSTALL BACKFILL AS SPECIFIED IN DIVISION 31 SECTION "EARTH MOVING." 3. AFTER INSTALLING CONDUIT, BACKFILL AND COMPACT. START ATTIE-IN POINT, AND WORK TOWARD END OF CONDUIT RUN, LEAVING CONDUIT AT END OF RUN FREE TO MOVE WITH EXPANSION AND CONTRACTION AS TEMPERATURE CHANGES DURING THIS PROCESS. FIRMLY HAND TAMP BACKFILL AROUND CONDUIT TO PROVIDE MAXIMUM SUPPORTING STRENGTH. AFTER PLACING CONTROLLED BACKFILL TO WITHIN 12 INCHES (300 MM) OF FINISHED GRADE, MAKE FINAL CONDUIT CONNECTION AT END OF RUN AND COMPLETE BACKFILLING WITH NORMAL COMPACTION AS SPECIFIED IN DIVISION 31 SECTION "EARTH MOVING." 4. INSTALL MANUFACTURED DUCT ELBOWS FOR STUB -UPS AT POLES AND EQUIPMENT AND AT BUILDING ENTRANCES THROUGH FLOOR UNLESS OTHERWISE INDICATED. ENCASE ELBOWS FOR STUB -UP DUCTS THROUGHOUT LENGTH OF ELBOW, 5. INSTALL MANUFACTURED RIGID STEEL CONDUIT ELBOWS FOR STUB -UPS AT POLES AND EQUIPMENTAND AT BUILDING ENTRANCES THROUGH FLOOR. a. COUPLE STEEL CONDUITS TO DUCTS WITH ADAPTERS DESIGNED FOR THIS PURPOSE, AND ENCASE COUPLING WITH 3INCHES (75 MM) OF CONCRETE FOR A MINIMUM OF 12 INCHES (300 MM) ON EACH SIDE OF THE COUPLING. b. FOR STUB -UPS AT EQUIPMENT MOUNTED ON OUTDOOR CONCRETE BASES AND WHERE CONDUITS PENETRATE BUILDING FOUNDATIONS, EXTEND STEEL CONDUIT HORIZONTALLY A MINIMUM OF 60 INCHES (1500 MM) FROM EDGE OF FOUNDATION OR EQUIPMENT BASE. INSTALL INSULATED GROUNDING BUSHINGS ON TERMINATIONS AT EQUIPMENT. 6. WARNING PLANKS: BURY WARNING PLANKS APPROXIMATELY 12 INCHES (300 MM) ABOVE DIRECT -BURIED CONDUITS BUT MINIMUM OF 6INCHES (150 MM) BELOW GRADE. ALIGN PLANKS ALONG CENTERLINE OF CONDUIT. 7. UNDERGROUND WARNING TAPE: COMPLY WITH REQUIREMENTS IN DIVISION 26 SECTION "IDENTIFICATION FOR ELECTRICAL SYSTEMS." 3.4 SLEEVE AND SLEEVE -SEAL INSTALLATION FOR ELECTRICAL PENETRATIONS A. INSTALL SLEEVES AND SLEEVE SEALS AT PENETRATIONS OF EXTERIOR FLOOR AND WALL ASSEMBLIES. COMPLY WITH REQUIREMENTS IN DIVISION 26 SECTION "SLEEVES AND SLEEVE SEALS FOR ELECTRICAL RACEWAYS AND CABLING." 3.5 FIRESTOPPING A. INSTALL FIRESTOPPING AT PENETRATIONS OF FIRE -RATED FLOOR AND WALL ASSEMBLIES. COMPLY WITH REQUIREMENTS IN DIVISION 07 SECTION "PENETRATION FIRESTOPPING." 3.6 PROTECTION A. PROTECT COATINGS AND FINISHES FROM DAMAGE AND DETERIORATION. 1. REPAIR DAMAGE TO GALVANIZED FINISHES WITH ZINC -RICH PAINT RECOMMENDED BY MANUFACTURER. 2. REPAIR DAMAGE TO PVC COATINGS OR PAINT FINISHES WITH MATCHING TOUCHUP COATING RECOMMENDED BY MANUFACTURER. END OF SECTION 260533 SECTION 260544 - SLEEVES AND SLEEVE SEALS FOR ELECTRICAL RACEWAYS AND CABLING I7:1:aiQeT��Iq:L11 1.1 RELATED DOCUMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO THIS SECTION, 1.2 SUMMARY A. SECTION INCLUDES: 1. SLEEVES FOR RACEWAY AND CABLE PENETRATION OF NON -FIRE -RATED CONSTRUCTION WALLS AND FLOORS. 2. SLEEVE -SEAL SYSTEMS. 3. SLEEVE -SEAL FITTINGS. 4. GROUT. 5. SILICONE SEALANTS. B. RELATED REQUIREMENTS: 1. DIVISION 07 SECTION "PENETRATION FIRESTOPPING" FOR PENETRATION FIRESTOPPING INSTALLED IN FIRE -RESISTANCE -RATED WALLS, HORIZONTAL ASSEMBLIES, AND SMOKE BARRIERS, WITH AND WITHOUT PENETRATING ITEMS. 1.3 ACTION SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT. B. LEED SUBMITTALS: 1. PRODUCT DATA FOR CREDIT EQ 4.1: FOR SEALANTS, DOCUMENTATION INCLUDING PRINTED STATEMENT OF VOC CONTENT. 2. LABORATORY TEST REPORTS FOR CREDIT EQ 4: FOR SEALANTS, DOCUMENTATION INDICATING THAT PRODUCTS COMPLY WITH THE TESTING AND PRODUCT REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF HEALTH SERVICES"'STANDARD PRACTICE FOR THE TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL CHAMBERS." PART2-PRODUCTS 2.1 SLEEVES A. WALL SLEEVES: 1, STEEL PIPE SLEEVES: ASTM A 53/A 53M, TYPE E, GRADE B, SCHEDULE 40, ZINC COATED, PLAIN ENDS. 2. CAST-IRON PIPE SLEEVES: CAST OR FABRICATED "WALL PIPE," EQUIVALENT TO DUCTILE -IRON PRESSURE PIPE, WITH PLAIN ENDS AND INTEGRAL WATERSTOP UNLESS OTHERWISE INDICATED, B. SLEEVES FOR CONDUITS PENETRATING NON -FIRE -RATED GYPSUM BOARD ASSEMBLIES: GALVANIZED -STEEL SHEET; 0.0239-INCH (0.6-MM) MINIMUM THICKNESS; ROUND TUBE CLOSED WITH WELDED LONGITUDINAL JOINT, WITH TABS FOR SCREW -FASTENING THE SLEEVE TO THE BOARD. C. PVC -PIPE SLEEVES: ASTM D 1785, SCHEDULE 40. D. MOLDED -PVC SLEEVES: WITH NAILING FLANGE FOR ATTACHING TO WOODEN FORMS. E. MOLDED -PE OR -PP SLEEVES: REMOVABLE, TAPERED -CUP SHAPED, AND SMOOTH OUTER SURFACE WITH NAILING FLANGE FOR ATTACHING TO WOODEN FORMS. F. SLEEVES FOR RECTANGULAR OPENINGS: 1. MATERIAL: GALVANIZED SHEET STEEL. 2. MINIMUM METAL THICKNESS: a. FOR SLEEVE CROSS-SECTION RECTANGLE PERIMETER LESS THAN 50 INCHES (1270 MM) AND WITH NO SIDE LARGER THAN 16 INCHES (400 MM), THICKNESS SHALL BE 0.052 INCH (1.3 MM). b. FOR SLEEVE CROSS-SECTION RECTANGLE PERIMETER 50 INCHES (1270 MM) OR MORE AND ONE OR MORE SIDES LARGER THAN 16INCHES (400 MM), THICKNESS SHALL BE 0.138 INCH (3.5 MM). 2.2 SLEEVE -SEAL SYSTEMS A. DESCRIPTION: MODULAR SEALING DEVICE, DESIGNED FOR FIELD ASSEMBLY, TO FILL ANNULAR SPACE BETWEEN SLEEVE AND RACEWAY OR CABLE. 1. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: a. ADVANCE PRODUCTS & SYSTEMS, INC. b. CALPICO, INC. C. METRAFLEX COMPANY (THE). d. PIPELINE SEAL AND INSULATOR, INC. e. PROCO PRODUCTS, INC. 2. SEALING ELEMENTS: EPDM RUBBER INTERLOCKING LINKS SHAPED TO FIT SURFACE OF PIPE. INCLUDE TYPE AND NUMBER REQUIRED FOR PIPE MATERIAL AND SIZE OF PIPE. 3. PRESSURE PLATES: CARBON STEEL. 4. CONNECTING BOLTS AND NUTS: CARBON STEEL, WITH CORROSION -RESISTANT COATING, OF LENGTH REQUIRED TO SECURE PRESSURE PLATES TO SEALING ELEMENTS. SECTION 260544 - SLEEVES AND SLEEVE SEALS FOR ELECTRICAL RACEWAYS AND CABLING CONTINUED 2.3 SLEEVE -SEAL FITTINGS A. DESCRIPTION: MANUFACTURED PLASTIC, SLEEVE -TYPE, WATERSTOP ASSEMBLY MADE FOR EMBEDDING IN CONCRETE SLAB OR WALL, UNIT SHALL HAVE PLASTIC OR RUBBER WATERSTOP COLLAR WITH CENTER OPENING TO MATCH PIPING OD. 1. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: a. PRESEALED SYSTEMS. 2.4 GROUT A. DESCRIPTION: NONSHRINK; RECOMMENDED FOR INTERIOR AND EXTERIOR SEALING OPENINGS IN NON -FIRE -RATED WALLS OR FLOORS. B. STANDARD: ASTM C 1107/C 1107M, GRADE B, POST -HARDENING AND VOLUME -ADJUSTING, DRY, HYDRAULIC -CEMENT GROUT. C. DESIGN MIX: 5000-PSI (34.5-MPA), 28-DAY COMPRESSIVE STRENGTH. D. PACKAGING: PREMIXED AND FACTORY PACKAGED. 2.5 SILICONE SEALANTS A. SILICONE SEALANTS: SINGLE -COMPONENT, SILICONE -BASED, NEUTRAL -CURING ELASTOMERIC SEALANTS OF GRADE INDICATED BELOW. 1. GRADE: POURABLE (SELF -LEVELING) FORMULATION FOR OPENINGS IN FLOORS AND OTHER HORIZONTAL SURFACES THAT ARE NOT FIRE RATED. B. SILICONE FOAMS: MULTICOMPONENT, SILICONE -BASED LIQUID ELASTOMERS THAT, WHEN MIXED, EXPAND AND CURE IN PLACE TO PRODUCE A FLEXIBLE, NONSHRINKING FOAM. PART 3 - EXECUTION 3.1 SLEEVE INSTALLATION FOR NON -FIRE -RATED ELECTRICAL PENETRATIONS A. COMPLY WITH NECA 1. B. COMPLY WITH NEMA VE 2 FOR CABLE TRAY AND CABLE PENETRATIONS. C. SLEEVES FOR CONDUITS PENETRATING ABOVE -GRADE NON -FIRE -RATED CONCRETE AND MASONRY -UNIT FLOORS AND WALLS: 1. INTERIOR PENETRATIONS OF NON -FIRE -RATED WALLS AND FLOORS: a. SEAL ANNULAR SPACE BETWEEN SLEEVE AND RACEWAY OR CABLE, USING JOINT SEALANT APPROPRIATE FOR SIZE, DEPTH, AND LOCATION OF JOINT. COMPLY WITH REQUIREMENTS IN DIVISION 07 SECTION "JOINT SEALANTS." b. SEAL SPACE OUTSIDE OF SLEEVES WITH MORTAR OR GROUT. PACK SEALING MATERIAL SOLIDLY BETWEEN SLEEVE AND WALL SO NO VOIDS REMAIN, TOOL EXPOSED SURFACES SMOOTH; PROTECT MATERIAL WHILE CURING. 2. USE PIPE SLEEVES UNLESS PENETRATION ARRANGEMENT REQUIRES RECTANGULAR SLEEVED OPENING. 3. SIZE PIPE SLEEVES TO PROVIDE 114-INCH (6.4-MM) ANNULAR CLEAR SPACE BETWEEN SLEEVE AND RACEWAY OR CABLE UNLESS SLEEVE SEAL IS TO BE INSTALLED. 4. INSTALL SLEEVES FOR WALL PENETRATIONS UNLESS CORE -DRILLED HOLES OR FORMED OPENINGS ARE USED. INSTALL SLEEVES DURING ERECTION OF WALLS, CUT SLEEVES TO LENGTH FOR MOUNTING FLUSH WITH BOTH SURFACES OF WALLS. DEBURR AFTER CUTTING. 5. INSTALL SLEEVES FOR FLOOR PENETRATIONS. EXTEND SLEEVES INSTALLED IN FLOORS 2 INCHES (50 MM) ABOVE FINISHED FLOOR LEVEL. INSTALL SLEEVES DURING ERECTION OF FLOORS. D. SLEEVES FOR CONDUITS PENETRATING NON -FIRE -RATED GYPSUM BOARD ASSEMBLIES: 1. USE CIRCULAR METAL SLEEVES UNLESS PENETRATION ARRANGEMENT REQUIRES RECTANGULAR SLEEVED OPENING. 2. SEAL SPACE OUTSIDE OF SLEEVES WITH APPROVED JOINT COMPOUND FOR GYPSUM BOARD ASSEMBLIES. E. ROOF -PENETRATION SLEEVES: SEAL PENETRATION OF INDIVIDUAL RACEWAYS AND CABLES WITH FLEXIBLE BOOT -TYPE FLASHING UNITS APPLIED IN COORDINATION WITH ROOFING WORK. F. ABOVEGROUND, EXTERIOR -WALL PENETRATIONS: SEAL PENETRATIONS USING STEEL PIPE SLEEVES AND MECHANICAL SLEEVE SEALS, SELECT SLEEVE SIZE TO ALLOW FOR 1-INCH (25-MM) ANNULAR CLEAR SPACE BETWEEN PIPE AND SLEEVE FOR INSTALLING MECHANICAL SLEEVE SEALS. G. UNDERGROUND, EXTERIOR -WALL AND FLOOR PENETRATIONS: INSTALL CAST-IRON PIPE SLEEVES. SIZE SLEEVES TO ALLOW FOR 1-INCH (25-MM) ANNULAR CLEAR SPACE BETWEEN RACEWAY OR CABLE AND SLEEVE FOR INSTALLING SLEEVE -SEAL SYSTEM. 3.2 SLEEVE -SEAL -SYSTEM INSTALLATION A. INSTALL SLEEVE -SEAL SYSTEMS IN SLEEVES IN EXTERIOR CONCRETE WALLS AND SLABS -ON -GRADE AT RACEWAY ENTRIES INTO BUILDING. B. INSTALL TYPE AND NUMBER OF SEALING ELEMENTS RECOMMENDED BY MANUFACTURER FOR RACEWAY OR CABLE MATERIAL AND SIZE. POSITION RACEWAY OR CABLE IN CENTER OF SLEEVE. ASSEMBLE MECHANICAL SLEEVE SEALS AND INSTALL IN ANNULAR SPACE BETWEEN RACEWAY OR CABLE AND SLEEVE. TIGHTEN BOLTS AGAINST PRESSURE PLATES THAT CAUSE SEALING ELEMENTS TO EXPAND AND MAKE WATERTIGHT SEAL. 3.3 SLEEVE -SEAL -FITTING INSTALLATION A. INSTALL SLEEVE -SEAL FITTINGS IN NEW WALLS AND SLABS AS THEY ARE CONSTRUCTED. B. ASSEMBLE FITTING COMPONENTS OF LENGTH TO BE FLUSH WITH BOTH SURFACES OF CONCRETE SLABS AND WALLS. POSITION WATERSTOP FLANGE TO BE CENTERED IN CONCRETE SLAB OR WALL. C. SECURE NAILING FLANGES TO CONCRETE FORMS. D. USING GROUT, SEAL THE SPACE AROUND OUTSIDE OF SLEEVE -SEAL FITTINGS. END OF SECTION 260544 SECTION 260553- IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1-GENERAL 1.1 SUMMARY A. SECTION INCLUDES: 1. IDENTIFICATION FOR RACEWAYS, 2. EQUIPMENT IDENTIFICATION LABELS. 3. MISCELLANEOUS IDENTIFICATION PRODUCTS. 1.2 QUALITY ASSURANCE A. COMPLY WITH ANSI A13.1, B. COMPLY WITH NFPA 70. C. COMPLY WITH 29 CFR 1910,144 AND 29 CFR 1910.145. PART2-PRODUCTS 2.1 POWER RACEWAY IDENTIFICATION MATERIALS A. COMPLY WITH NFPA 70 FOR MINIMUM SIZE OF LETTERS FOR LEGEND AND FOR MINIMUM LENGTH OF COLOR FIELD FOR EACH RACEWAY SIZE. B. COLORS FOR RACEWAYS CARRYING CIRCUITS AT 600 V OR LESS: 1. BLACK LETTERS ON AN ORANGE FIELD. 2. LEGEND: INDICATE VOLTAGE C. SNAP -AROUND LABELS FOR RACEWAYS CARRYING CIRCUITS AT 600 V OR LESS: SLIT, PRETENSIONED, FLEXIBLE, PREPRINTED, COLOR -CODED ACRYLIC SLEEVE, WITH DIAMETER SIZED TO SUIT DIAMETER OF RACEWAY OR CABLE IT IDENTIFIES AND TO STAY IN PLACE BY GRIPPING ACTION. D. WRITE -ON TAGS: POLYESTER TAG, 0.010 INCH (0.25 MM) THICK, WITH CORROSION -RESISTANT GROMMET AND CABLE TIE FOR ATTACHMENT TO CONDUCTOR OR CABLE. 1. MARKER FOR TAGS: PERMANENT, WATERPROOF, BLACK INK MARKER RECOMMENDED BY TAG MANUFACTURER. 2.2 EQUIPMENT IDENTIFICATION LABELS A. STENCILED LEGEND: IN NONFADING, WATERPROOF, BLACK INK OR PAINT. MINIMUM LETTER HEIGHT SHALL BE 1 INCH (25 MM). 2.3 MISCELLANEOUS IDENTIFICATION PRODUCTS A. PAINT: COMPLY WITH REQUIREMENTS IN DIVISION 09 PAINTING SECTIONS FOR PAINT MATERIALS AND APPLICATION REQUIREMENTS. SELECT PAINT SYSTEM APPLICABLE FOR SURFACE MATERIAL AND LOCATION (EXTERIOR OR INTERIOR). B. FASTENERS FOR LABELS AND SIGNS: SELF -TAPPING, STAINLESS -STEEL SCREWS OR STAINLESS -STEEL MACHINE SCREWS WITH NUTS AND FLAT AND LOCK WASHERS. PART 3-EXECUTION 3.1 INSTALLATION A. LOCATION: INSTALL IDENTIFICATION MATERIALS AND DEVICES AT LOCATIONS FOR MOST CONVENIENT VIEWING WITHOUT INTERFERENCE WITH OPERATION AND MAINTENANCE OF EQUIPMENT. B. APPLY IDENTIFICATION DEVICES TO SURFACES THAT REQUIRE FINISH AFTER COMPLETING FINISH WORK. C. ATTACH SIGNS AND PLASTIC LABELS THAT ARE NOT SELF-ADHESIVE TYPE WITH MECHANICAL FASTENERS APPROPRIATE TO THE LOCATION AND SUBSTRATE: D. PAINTED IDENTIFICATION: COMPLY WITH REQUIREMENTS IN DIVISION 09 PAINTING SECTIONS FOR SURFACE PREPARATION AND PAINT APPLICATION. 3.2 IDENTIFICATION SCHEDULE A. ACCESSIBLE RACEWAYS AND CABLES WITHIN BUILDINGS: IDENTIFY THE COVERS OF EACH JUNCTION AND PULL BOX OF THE POWER SYSTEMS WITH THE WIRING SYSTEM LEGEND AND SYSTEM VOLTAGE. B. POWER -CIRCUIT CONDUCTOR IDENTIFICATION, 600 V OR LESS: FOR CONDUCTORS INJUNCTION BOXES, AND HANDHOLES, USE COLOR -CODING CONDUCTORS TO IDENTIFY THE PHASE. 1. COLOR -CODING FOR PHASE AND VOLTAGE LEVEL IDENTIFICATION, 600 V OR LESS: USE COLORS LISTED BELOW FOR UNGROUNDED SERVICE FEEDER, SUB -FEEDERS AND BRANCH -CIRCUIT CONDUCTORS. a. COLOR SHALL BE FACTORY APPLIED OR FIELD APPLIED FOR SIZES LARGER THAN NO, 8 AWG, IF AUTHORITIES HAVING JURISDICTION PERMIT. b. COLORS FOR 208/120-V CIRCUITS: 1) PHASE A: BLACK. 2) PHASE B: RED. 3) PHASE C: BLUE. C. COLORS FOR 480/277-V CIRCUITS: 1) PHASE A: BROWN. 2) PHASE B: ORANGE. 3) PHASE C: YELLOW. C. EQUIPMENT IDENTIFICATION LABELS: ON EACH UNIT OF EQUIPMENT, INSTALL UNIQUE DESIGNATION LABEL THAT IS CONSISTENT WITH WIRING DIAGRAMS, SCHEDULES, AND THE OPERATION AND MAINTENANCE MANUAL, APPLY LABELS TO DISCONNECT SWITCHES AND PROTECTION EQUIPMENT, CENTRAL OR MASTER UNITS, CONTROL PANELS, AND TERMINAL CABINETS OF EACH SYSTEM. SYSTEMS INCLUDE POWER, LIGHTING, CONTROL, COMMUNICATION, SIGNAL, MONITORING, AND ALARM SYSTEMS UNLESS EQUIPMENT IS PROVIDED WITH ITS OWN IDENTIFICATION. 1. LABELING INSTRUCTIONS: a. INDOOR EQUIPMENT: ENGRAVED, LAMINATED ACRYLIC OR MELAMINE LABEL, UNLESS OTHERWISE INDICATED, PROVIDE A SINGLE LINE OF TEXT WITH 1/2-INCH- (13-MM-) HIGH LETTERS ON 1-1/2-INCH- (38-MM-) HIGH LABEL; WHERE TWO LINES OF TEXT ARE REQUIRED, USE LABELS 2 INCHES (50 MM) HIGH. b. OUTDOOR EQUIPMENT: ENGRAVED, LAMINATED ACRYLIC OR MELAMINE LABEL C. ELEVATED COMPONENTS; INCREASE SIZES OF LABELS AND LETTERS TO THOSE APPROPRIATE FOR VIEWING FROM THE FLOOR. d. UNLESS PROVIDED WITH SELF-ADHESIVE MEANS OF ATTACHMENT, FASTEN LABELS WITH APPROPRIATE MECHANICAL FASTENERS THAT DO NOT CHANGE THE NEMA OR NRTL RATING OF THE ENCLOSURE. END OF SECTION 260553 SECTION 262413-SWITCHBOARDS PART 1-GENERAL 1.1 RELATED DOCUMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. 1.2 SUMMARY A. SECTION INCLUDES: 1. SERVICE AND DISTRIBUTION SWITCHBOARDS RATED 600 V AND LESS. 2. SURGE PROTECTION DEVICES. 3. DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES. 4. INSTRUMENTATION. 5. CONTROL POWER. 6. ACCESSORY COMPONENTS AND FEATURES. 7. IDENTIFICATION. 1.3 SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF SWITCHBOARD, OVERCURRENT PROTECTIVE DEVICE, SURGE PROTECTION DEVICE, GROUND -FAULT PROTECTOR, ACCESSORY, AND COMPONENT INDICATED. INCLUDE DIMENSIONS AND MANUFACTURERS' TECHNICAL DATA ON FEATURES, PERFORMANCE, ELECTRICAL CHARACTERISTICS, RATINGS, ACCESSORIES, AND FINISHES. B. SHOP DRAWINGS: FOR EACH SWITCHBOARD AND RELATED EQUIPMENT. 1. INCLUDE DIMENSIONED PLANS, ELEVATIONS, SECTIONS, AND DETAILS, INCLUDING REQUIRED CLEARANCES AND SERVICE SPACE AROUND EQUIPMENT. SHOW TABULATIONS OF INSTALLED DEVICES, EQUIPMENT FEATURES, AND RATINGS. 2. DETAIL ENCLOSURE TYPES FOR TYPES OTHER THAN NEMA 250, TYPE 1, 3. DETAIL BUS CONFIGURATION, CURRENT, AND VOLTAGE RATINGS. 4. DETAILED SHORT-CIRCUIT CURRENT RATING OF SWITCHBOARDS AND OVERCURRENT PROTECTIVE DEVICES. 5. DETAIL FEATURES, CHARACTERISTICS, RATINGS, AND FACTORY SETTINGS OF INDIVIDUAL OVERCURRENT PROTECTIVE DEVICES AND AUXILIARY COMPONENTS. 6. INCLUDE TIME -CURRENT COORDINATION CURVES FOR EACH TYPE AND RATING OF OVERCURRENT PROTECTIVE DEVICE INCLUDED IN SWITCHBOARDS. SUBMIT ON TRANSLUCENT LOG -LOG GRAFT PAPER; INCLUDE SELECTABLE RANGES FOR EACH TYPE OF OVERCURRENT PROTECTIVE DEVICE. 7. INCLUDE SCHEMATIC AND WIRING DIAGRAMS FOR POWER, SIGNAL, AND CONTROL WIRING. C. QUALIFICATION DATA: FOR QUALIFIED INSTALLER. D. FIELD QUALITY -CONTROL REPORTS: 1. TEST PROCEDURES USED. 2. TEST RESULTS THAT COMPLY WITH REQUIREMENTS. 3. RESULTS OF FAILED TESTS AND CORRECTIVE ACTION TAKEN TO ACHIEVE TEST RESULTS THAT COMPLY WITH REQUIREMENTS. E. OPERATION AND MAINTENANCE DATA: FOR SWITCHBOARDS AND COMPONENTS TO INCLUDE IN EMERGENCY, OPERATION, AND MAINTENANCE MANUALS. IN ADDITION TO ITEMS SPECIFIED IN DIVISION 01 SECTION "OPERATION AND MAINTENANCE DATA," INCLUDE THE FOLLOWING: 1. ROUTINE MAINTENANCE REQUIREMENTS FOR SWITCHBOARDS AND ALL INSTALLED COMPONENTS. 2. MANUFACTURER'S WRITTEN INSTRUCTIONS FOR TESTING AND ADJUSTING OVERCURRENT PROTECTIVE DEVICES. 3. TIME -CURRENT COORDINATION CURVES FOR EACH TYPE AND RATING OF OVERCURRENT PROTECTIVE DEVICE INCLUDED IN SWITCHBOARDS. SUBMIT ON TRANSLUCENT LOG -LOG GRAFT PAPER; INCLUDE SELECTABLE RANGES FOR EACH TYPE OF OVERCURRENT PROTECTIVE DEVICE. 1.4 QUALITY ASSURANCE A. INSTALLER QUALIFICATIONS: AN EMPLOYER OF WORKERS QUALIFIED AS DEFINED IN NEMA PB 2.1 AND TRAINED IN ELECTRICAL SAFETY AS REQUIRED BY NFPA 70E, B. TESTING AGENCY QUALIFICATIONS: MEMBER COMPANY OF NETA OR AN NRTL. 1. TESTING AGENCY'S FIELD SUPERVISOR: CURRENTLY CERTIFIED BY NETA TO SUPERVISE ON -SITE TESTING. C. SOURCE LIMITATIONS: OBTAIN SWITCHBOARDS, OVERCURRENT PROTECTIVE DEVICES, COMPONENTS, AND ACCESSORIES FROM SINGLE SOURCE FROM SINGLE MANUFACTURER. D. PRODUCT SELECTION FOR RESTRICTED SPACE: DRAWINGS INDICATE MAXIMUM DIMENSIONS FOR SWITCHBOARDS INCLUDING CLEARANCES BETWEEN SWITCHBOARDS AND ADJACENT SURFACES AND OTHER ITEMS. COMPLY WITH INDICATED MAXIMUM DIMENSIONS. E. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. F. COMPLY WITH NEMA PB 2. G. COMPLY WITH NFPA 70. H. COMPLY WITH UL 891. 1.5 DELIVERY, STORAGE, AND HANDLING A. DELIVER SWITCHBOARDS IN SECTIONS OR LENGTHS THAT CAN BE MOVED PAST OBSTRUCTIONS IN DELIVERY PATH. B. REMOVE LOOSE PACKING AND FLAMMABLE MATERIALS FROM INSIDE SWITCHBOARDS AND INSTALL TEMPORARY ELECTRIC HEATING (250 W PER SECTION) TO PREVENT CONDENSATION. C. HANDLE AND PREPARE SWITCHBOARDS FOR INSTALLATION ACCORDING TO NEMA PB 2.1. 1.6 PROJECT CONDITIONS A. INSTALLATION PATHWAY: PREPARE PATHWAYS FOR MOVING SWITCHBOARDS INTO PLACE. B. ENVIRONMENTAL LIMITATIONS: 1. DO NOT DELIVER OR INSTALL SWITCHBOARDS UNTIL SPACES ARE ENCLOSED AND WEATHERTIGHT, WET WORK IN SPACES IS COMPLETE AND DRY, WORK ABOVE SWITCHBOARDS IS COMPLETE, AND TEMPORARY HVAC SYSTEM IS OPERATING AND MAINTAINING AMBIENT TEMPERATURE AND HUMIDITY CONDITIONS AT OCCUPANCY LEVELS DURING THE REMAINDER OF THE CONSTRUCTION PERIOD. 2. RATE EQUIPMENT FOR CONTINUOUS OPERATION UNDER THE FOLLOWING CONDITIONS UNLESS OTHERWISE INDICATED: a. AMBIENT TEMPERATURE: NOT EXCEEDING 104 DEG F (40 DEG C). b. ALTITUDE: NOT EXCEEDING 6600 FEET (2000 M). C. SERVICE CONDITIONS: NEMA PB 2, USUAL SERVICE CONDITIONS, AS FOLLOWS: 1. AMBIENT TEMPERATURES WITHIN LIMITS SPECIFIED. 2. ALTITUDE NOT EXCEEDING 6600 FEET (2000 M). D. INTERRUPTION OF EXISTING ELECTRIC SERVICE: DO NOT INTERRUPT ELECTRIC SERVICE TO FACILITIES OCCUPIED BY OWNER OR OTHERS UNLESS PERMITTED UNDER THE FOLLOWING CONDITIONS AND THEN ONLY AFTER ARRANGING TO PROVIDE TEMPORARY ELECTRIC SERVICE ACCORDING TO REQUIREMENTS INDICATED: 1. NOTIFY OWNER NO FEWER THAN SEVEN DAYS IN ADVANCE OF PROPOSED INTERRUPTION OF ELECTRIC SERVICE, 2. INDICATE METHOD OF PROVIDING TEMPORARY ELECTRIC SERVICE. 3. DO NOT PROCEED WITH INTERRUPTION OF ELECTRIC SERVICE WITHOUT OWNER'S WRITTEN PERMISSION. 4. COMPLY WITH NFPA 70E. 1.7 COORDINATION A. COORDINATE LAYOUT AND INSTALLATION OF SWITCHBOARDS AND COMPONENTS WITH OTHER CONSTRUCTION THAT PENETRATES WALLS OR IS SUPPORTED BY THEM, INCLUDING ELECTRICAL AND OTHER TYPES OF EQUIPMENT, RACEWAYS, PIPING, ENCUMBRANCES TO WORKSPACE CLEARANCE REQUIREMENTS, AND ADJACENT SURFACES. MAINTAIN REQUIRED WORKSPACE CLEARANCES AND REQUIRED CLEARANCES FOR EQUIPMENT ACCESS DOORS AND PANELS. B. COORDINATE SIZES AND LOCATIONS OF CONCRETE BASES WITH ACTUAL EQUIPMENT PROVIDED. CAST ANCHOR -BOLT INSERTS INTO BASES. CONCRETE, REINFORCEMENT, AND FORMWORK REQUIREMENTS ARE SPECIFIED IN DIVISION 03. 1.8 WARRANTY A. SPECIAL WARRANTY: MANUFACTURER'S STANDARD FORM IN WHICH MANUFACTURER AGREES TO REPAIR OR REPLACE SURGE PROTECTION DEVICES THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN SPECIFIED WARRANTY PERIOD, 1. WARRANTY PERIOD: FIVE YEARS FROM DATE OF SUBSTANTIAL COMPLETION. 1.9 EXTRA MATERIALS A. FURNISH EXTRA MATERIALS THAT MATCH PRODUCTS INSTALLED AND THAT ARE PACKAGED WITH PROTECTIVE COVERING FOR STORAGE AND IDENTIFIED WITH LABELS DESCRIBING CONTENTS. 1. CONTROL -POWER FUSES: EQUAL TO 10 PERCENT OF QUANTITY INSTALLED FOR EACH SIZE AND TYPE, BUT NO FEWER THAN TWO OF EACH SIZE AND TYPE. 2. INDICATING LIGHTS: EQUAL TO 10 PERCENT OF QUANTITY INSTALLED FOR EACH SIZE AND TYPE, BUT NO FEWER THAN ONE OF EACH SIZE AND TYPE. PART2-PRODUCTS 2.1 MANUFACTURED UNITS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1 EATON ELECTRICAL INC.' CUTLER -HAMMER BUSINESS UNIT. 2. GENERAL ELECTRIC COMPANY; GE CONSUMER & INDUSTRIAL - ELECTRICAL DISTRIBUTION. 3. SIEMENS ENERGY & AUTOMATION, INC. 4. SQUARE D; A BRAND OF SCHNEIDER ELECTRIC. B. FR0 NT-CONNECTED FRONT -ACCESSIBLE SWITCHBOARDS: 1. MAIN DEVICES: FIXED, INDIVIDUALLY MOUNTED. 2. BRANCH DEVICES: PANEL MOUNTED. 3. SECTIONS FRONT AND REAR ALIGNED. C. NOMINAL SYSTEM VOLTAGE: 480YI277 V. D. MAIN -BUS CONTINUOUS: 1600A. E. INDOOR ENCLOSURES: STEEL, NEMA 250, TYPE 1. F. ENCLOSURE FINISH FOR INDOOR UNITS: FACTORY -APPLIED FINISH IN MANUFACTURER'S STANDARD GRAY FINISH OVER A RUST -INHIBITING PRIMER ON TREATED METAL SURFACE. G. BARRIERS: BETWEEN ADJACENT SWITCHBOARD SECTIONS. H. INSULATION AND ISOLATION FOR MAIN BUS OF MAIN SECTION AND MAIN AND VERTICAL BUSES OF FEEDER SECTIONS. I. CUBICAL SPACE HEATERS: FACTORY -INSTALLED ELECTRIC SPACE HEATERS OF SUFFICIENT WATTAGE IN EACH VERTICAL SECTION TO MAINTAIN ENCLOSURE TEMPERATURE ABOVE EXPECTED DEW POINT. 1. SPACE -HEATER CONTROL: THERMOSTATS TO MAINTAIN TEMPERATURE OF EACH SECTION ABOVE EXPECTED DEW POINT. 2. SPACE -HEATER POWER SOURCE: TRANSFORMER, FACTORY INSTALLED IN SWITCHBOARD J. CUSTOMER METERING COMPARTMENT: A SEPARATE CUSTOMER METERING COMPARTMENT AND SECTION WITH FRONT HINGED DOOR, FOR INDICATED METERING, AND CURRENT TRANSFORMERS FOR EACH METER. CURRENT TRANSFORMER SECONDARY WIRING SHALL BE TERMINATED ON SHORTING -TYPE TERMINAL BLOCKS. K. BUS TRANSITION AND INCOMING PULL SECTIONS: MATCHED AND ALIGNED WITH BASIC SWITCHBOARD. L. HINGED FRONT PANELS: ALLOW ACCESS TO CIRCUIT BREAKER, METERING, ACCESSORY, AND BLANK COMPARTMENTS, M. PULL BOX ON TOP OF SWITCHBOARD: 1. ADEQUATE VENTILATION TO MAINTAIN TEMPERATURE IN PULL BOX WITHIN SAME LIMITS AS SWITCHBOARD, 2. SET BACK FROM FRONT TO CLEAR CIRCUIT -BREAKER REMOVAL MECHANISM. 3. REMOVABLE COVERS SHALL FORM TOP, FRONT, AND SIDES. TOP COVERS AT REAR SHALL BE EASILY REMOVABLE FOR DRILLING AND CUTTING. 4. BOTTOM SHALL BE INSULATING, FIRE -RESISTIVE MATERIAL WITH SEPARATE HOLES FOR CABLE DROPS INTO SWITCHBOARD. 5. CABLE SUPPORTS SHALL BE ARRANGED TO FACILITATE CABLING AND ADEQUATE TO SUPPORT CABLES INDICATED, INCLUDING THOSE FOR FUTURE INSTALLATION. Sims Wilkerson Carte Engineering, Inc. 12124 High Tech Avenue - Suite. 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-5900 FL. CERT. OF AUTH. NO. 6106 oGA YA. W6,R RSOT, PE. 43167 06TUA Ce =P, P,E. 53269 o AI S. LEVME. P.E. 77010 C .IEPF A. IGR\4 ,PE. 656N 0 SA =L R ALE\A\R ER P£. 55 M 14001 *; NO , % STATE OF ;'� /////A71111111 S'oNAt e�G\��� \\\\\\ I In 0 s s U_ F_ U Cn L1J cU "F'•' (n _0 UU 1 1 1 0) I- O A 0 LL O z •O .� O � L � V Q O �% Q C)U o U Lz •U U - U U U =3 w J Q J ^w LL vJ v! 2 w O LO L= o W C)M m Iq CID rvr^J VJ SECTION 262413 - SWITCHBOARDS CONTINUED N. BUSES AND CONNECTIONS: THREE PHASE, FOUR WIRE UNLESS OTHERWISE INDICATED. 1. PHASE -AND NEUTRAL -BUS MATERIAL: HARD -DRAWN COPPER OF 98 PERCENT CONDUCTIVITY, SILVER-PLATED, WITH TIN-PLATED ALUMINUM OR COPPER FEEDER CIRCUIT -BREAKER LINE CONNECTIONS. 2. GROUND BUS: 1/4-BY-2-INCH- (6-BY-50-MM-) HARD -DRAWN COPPER OF 98 PERCENT CONDUCTIVITY, EQUIPPED WITH MECHANICAL CONNECTORS FOR FEEDER AND BRANCH -CIRCUIT GROUND CONDUCTORS. 3. MAIN PHASE BUSES AND EQUIPMENT GROUND BUSES: UNIFORM CAPACITY FOR ENTIRE LENGTH OF SWITCHBOARD'S MAIN AND DISTRIBUTION SECTIONS. PROVIDE FOR FUTURE EXTENSIONS FROM BOTH ENDS. 4. NEUTRAL BUSES: 100 PERCENT OF THE AMPACITY OF PHASE BUSES UNLESS OTHERWISE INDICATED, EQUIPPED WITH MECHANICAL CONNECTORS FOR OUTGOING CIRCUIT NEUTRAL CABLES, 0. FUTURE DEVICES: EQUIP COMPARTMENTS WITH MOUNTING BRACKETS, SUPPORTS, BUS CONNECTIONS, AND APPURTENANCES AT FULL RATING OF CIRCUIT -BREAKER COMPARTMENT. P. FUNGUS PROOFING: PERMANENT FUNGICIDAL TREATMENT FOR OVERCURRENT PROTECTIVE DEVICES AND OTHER COMPONENTS INCLUDING INSTRUMENTS AND INSTRUMENT TRANSFORMERS. 2.2 SURGE PROTECTION DEVICES A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. EATON ELECTRICAL INC.; CUTLER -HAMMER BUSINESS UNIT. 2. GENERAL ELECTRIC COMPANY; GE CONSUMER & INDUSTRIAL - ELECTRICAL DISTRIBUTION. 3. SIEMENS ENERGY& AUTOMATION, INC. 4. SQUARE D; A BRAND OF SCHNEIDER ELECTRIC, B. SURGE PROTECTION DEVICE DESCRIPTION: IEEE C62.41-COMPLIANT, INTEGRALLY MOUNTED, OR FIELD -MOUNTED, SOLID-STATE, PARALLEL -CONNECTED, MODULAR (WITH FIELD -REPLACEABLE MODULES) TYPE, WITH SINE -WAVE TRACKING SUPPRESSION AND FILTERING MODULES, UL 1449, SECOND EDITION, SHORT-CIRCUIT CURRENT RATING MATCHING OR EXCEEDING THE SWITCHBOARD SHORT-CIRCUIT RATING, AND WITH THE FOLLOWING FEATURES AND ACCESSORIES: 1. FABRICATION USING BOLTED COMPRESSION LUGS FOR INTERNAL WIRING. 2. REDUNDANT SUPPRESSION CIRCUITS. 3. REDUNDANT REPLACEABLE MODULES. 4. ARRANGEMENT WITH WIRE CONNECTIONS TO PHASE BUSES, NEUTRAL BUS, AND GROUND BUS. 5. LED INDICATOR LIGHTS FOR POWER AND PROTECTION STATUS. 6. AUDIBLE ALARM, WITH SILENCING SWITCH, TO INDICATE WHEN PROTECTION HAS FAILED. 7. FORM-C CONTACTS RATED AT 5 A AND 250-V AC, ONE NORMALLY OPEN AND ONE NORMALLY CLOSED, FOR REMOTE MONITORING OF SYSTEM OPERATION. CONTACTS SHALL REVERSE POSITION ON FAILURE OF ANY SURGE DIVERSION MODULE OR ON OPENING OF ANY CURRENT -LIMITING DEVICE. COORDINATE WITH BUILDING POWER MONITORING AND CONTROL SYSTEM. 8. FOUR -DIGIT, TRANSIENT -EVENT COUNTER SET TO TOTALIZE TRANSIENT SURGES. C. PEAK SINGLE -IMPULSE SURGE CURRENT RATING: 120 KA PER MODE/240 KA PER PHASE. D. WITHSTAND CAPABILITIES: 12,000IEEE C62.41, CATEGORY C3 (10 KA), 8-BY-20-MIC,SEC. SURGES WITH LESS THAN 5 PERCENT CHANGE IN CLAMPING VOLTAGE. E. PROTECTION MODES AND UL 1449 SVR FOR GROUNDED WYE CIRCUITS WITH 4BOY/277 V, THREE-PHASE, FOUR -WIRE CIRCUITS SHALL BE AS FOLLOWS: 1. LINE TO NEUTRAL: 800 V FOR 480Y/277. 2. LINE TO GROUND: 800 V FOR 480Y/277. 3. NEUTRAL TO GROUND: 800 V FOR 480Y1277. 2.3 DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES A. MOLDED -CASE CIRCUIT BREAKER (MCCB): COMPLY WITH UL 489, WITH INTERRUPTING CAPACITY TO MEET AVAILABLE FAULT CURRENTS. 1. THERMAL -MAGNETIC CIRCUIT BREAKERS: INVERSE TIME -CURRENT ELEMENT FOR LOW-LEVEL OVERLOADS, AND INSTANTANEOUS MAGNETIC TRIP ELEMENT FOR SHORT CIRCUITS, ADJUSTABLE MAGNETIC TRIP SETTING FOR CIRCUIT -BREAKER FRAME SIZES 250 AAND LARGER. 2. ADJUSTABLE INSTANTANEOUS -TRIP CIRCUIT BREAKERS: MAGNETIC TRIP ELEMENT WITH FRONT -MOUNTED, FIELD -ADJUSTABLE TRIP SETTING. 3. ELECTRONIC TRIP CIRCUIT BREAKERS WITH RIMS SENSING; FIELD -REPLACEABLE RATING PLUG OR FIELD-REPLICABLE ELECTRONIC TRIP; AND THE FOLLOWING FIELD -ADJUSTABLE SETTINGS: a. INSTANTANEOUS TRIP. b. LONG -AND SHORT -TIME PICKUP LEVELS. C. LONG- AND SHORT -TIME TIME ADJUSTMENTS. d. GROUND -FAULT PICKUP LEVEL, TIME DELAY, AND 12T RESPONSE. 4. GFCI CIRCUIT BREAKERS: SINGLE -AND TWO -POLE CONFIGURATIONS WITH CLASS A GROUND -FAULT PROTECTION (6-MA TRIP). 5. MOLDED -CASE CIRCUIT -BREAKER (MCCB) FEATURES AND ACCESSORIES: a. STANDARD FRAME SIZES, TRIP RATINGS, AND NUMBER OF POLES. b. LUGS: MECHANICAL STYLE, SUITABLE FOR NUMBER, SIZE, TRIP RATINGS, AND CONDUCTOR MATERIAL. C. APPLICATION LISTING: APPROPRIATE FOR APPLICATION; TYPE SWD FOR SWITCHING FLUORESCENT LIGHTING LOADS; TYPE HID FOR FEEDING FLUORESCENTAND HIGH -INTENSITY DISCHARGE (HID) LIGHTING CIRCUITS. d. GROUND -FAULT PROTECTION: INTEGRALLY MOUNTED RELAY AND TRIP UNIT WITH ADJUSTABLE PICKUP AND TIME -DELAY SETTINGS, PUSH -TO -TEST FEATURE, AND GROUND -FAULT INDICATOR. e. SHUNT TRIP: 120-V TRIP COIL ENERGIZED FROM SEPARATE CIRCUIT, SET TO TRIP AT 155] [75] PERCENT OF RATED VOLTAGE. f. UNDERVOLTAGE TRIP: SET TO OPERATE AT 35 TO 75 PERCENT OF RATED VOLTAGE WITHOUT INTENTIONAL TIME DELAY. 2.4 INSTRUMENTATION A. INSTRUMENT TRANSFORMERS: IEEE C57,13, NEMA El 21.1, AND THE FOLLOWING: 1. CURRENT TRANSFORMERS: IEEE C57.13; 5 A, 60 HZ, SECONDARY; BAR OR WINDOW TYPE; SINGLE SECONDARY WINDING AND SECONDARY SHORTING DEVICE. BURDEN AND ACCURACY SHALL BE CONSISTENT WITH CONNECTED METERING AND RELAY DEVICES. 2. CONTROL -POWER TRANSFORMERS: DRY TYPE, MOUNTED IN SEPARATE COMPARTMENTS FOR UNITS LARGER THAN 3 KVA. B. MULTIFUNCTION DIGITAL -METERING MONITOR: MICROPROCESSOR -BASED UNIT SUITABLE FOR THREE- OR FOUR -WIRE SYSTEMS AND WITH THE FOLLOWING FEATURES: 1. SWITCH -SELECTABLE DIGITAL DISPLAY OF THE FOLLOWING VALUES WITH MAXIMUM ACCURACY TOLERANCES AS INDICATED: a. PHASE CURRENTS, EACH PHASE: PLUS OR MINUS 1 PERCENT. b. PHASE -TO -PHASE VOLTAGES, THREE PHASE: PLUS OR MINUS 1 PERCENT. C. PHASE -TO -NEUTRAL VOLTAGES, THREE PHASE: PLUS OR MINUS 1 PERCENT. d. MEGAWATTS: PLUS OR MINUS 2 PERCENT. e. MEGAVARS: PLUS OR MINUS 2 PERCENT. f. POWER FACTOR: PLUS OR MINUS 2 PERCENT. g. FREQUENCY: PLUS OR MINUS 0.5 PERCENT. h. ACCUMULATED ENERGY, MEGAWATT HOURS: PLUS OR MINUS 2 PERCENT; ACCUMULATED VALUES UNAFFECTED BY POWER OUTAGES UP TO 72 HOURS. i MEGAWATT DEMAND: PLUS OR MINUS 2 PERCENT; DEMAND INTERVAL PROGRAMMABLE FROM FIVE TO 60 MINUTES. j. CONTACT DEVICES TO OPERATE REMOTE IMPULSE -TOTALIZING DEMAND METER. 2. MOUNTING: DISPLAY AND CONTROL UNIT FLUSH OR SEMIFLUSH MOUNTED IN INSTRUMENT COMPARTMENT DOOR. A. FEEDER AMMETERS: 2-1/2-INCH (64-MM) MINIMUM SIZE WITH 90- OR 120-DEGREE SCALE. METER AND TRANSFER DEVICE WITH OFF POSITION, LOCATED ON OVERCURRENT DEVICE DOOR FOR INDICATED FEEDER CIRCUITS ONLY. B. WATT-HOUR METERS AND WATTMETERS: 1. COMPLY WITH ANSI C12.1. 2. THREE-PHASE INDUCTION TYPE WITH TWO STATORS, EACH WITH CURRENT AND POTENTIAL COIL, RATED 5 A, 120 V, 60 HZ. 3. SUITABLE FOR CONNECTION TO THREE- AND FOUR -WIRE CIRCUITS. 4. POTENTIAL INDICATING LAMPS. 5. ADJUSTMENTS FOR LIGHT AND FULL LOAD, PHASE BALANCE, AND POWER FACTOR, 6. FOUR -DIAL CLOCK REGISTER. 7. INTEGRAL DEMAND INDICATOR, 8. CONTACT DEVICES TO OPERATE REMOTE IMPULSE -TOTALIZING DEMAND METER. 9. RATCHETS TO PREVENT REVERSE ROTATION. 10. REMOVABLE METER WITH DRAWOUT TEST PLUG. 11. SEMIFLUSH MOUNTED CASE WITH MATCHING COVER. 12. APPROPRIATE MULTIPLIER TAG. E. IMPULSE -TOTALIZING DEMAND METER: 1. COMPLY WITH ANSI C12.1. 2. SUITABLE FOR USE WITH SWITCHBOARD WATT-HOUR METER, INCLUDING TWO -CIRCUIT TOTALIZING RELAY. 3. CYCLOMETER. 4. FOUR -DIAL, TOTALIZING KILOWATT-HOUR REGISTER. 5. POSITIVE CHART DRIVE MECHANISM. 6. CAPILLARY PEN HOLDING A MINIMUM OF ONE MONTH'S INK SUPPLY. 7. ROLL CHART WITH MINIMUM 31-DAY CAPACITY; APPROPRIATE MULTIPLIER TAG. 8. CAPABLE OF INDICATING AND RECORDING 15-MINUTE INTEGRATED DEMAND OF TOTALIZED SYSTEM. 2.5 CONTROL POWER A. CONTROL CIRCUITS: 120-VAC, SUPPLIED THROUGH SECONDARY DISCONNECTING DEVICES FROM CONTROL -POWER TRANSFORMER. B. CONTROL CIRCUITS: 120-V AC, SUPPLIED FROM REMOTE BRANCH CIRCUIT. C. CONTROL CIRCUITS: 24-V DC. D. CONTROL -POWER FUSES: PRIMARY AND SECONDARY FUSES FOR CURRENT -LIMITING AND OVERLOAD PROTECTION OF TRANSFORMER AND FUSES FOR PROTECTION OF CONTROL CIRCUITS. E. CONTROL WIRING: FACTORY INSTALLED, WITH BUNDLING, LACING, AND PROTECTION INCLUDED. PROVIDE FLEXIBLE CONDUCTORS FOR NO.8 AWG AND SMALLER, FOR CONDUCTORS ACROSS HINGES, AND FOR CONDUCTORS FOR INTERCONNECTIONS BETWEEN SHIPPING UNITS. 2.6 ACCESSORY COMPONENTS AND FEATURES A. ACCESSORY SET: INCLUDE TOOLS AND MISCELLANEOUS ITEMS REQUIRED FOR OVERCURRENT PROTECTIVE DEVICE TEST, INSPECTION, MAINTENANCE, AND OPERATION. B. PORTABLE TEST SET: FOR TESTING FUNCTIONS OF SOLID-STATE TRIP DEVICES WITHOUT REMOVING FROM SWITCHBOARD. INCLUDE RELAY AND METER TEST PLUGS SUITABLE FOR TESTING SWITCHBOARD METERS AND SWITCHBOARD CLASS RELAYS, C. SPARE -FUSE CABINET: SUITABLY IDENTIFIED, WALL -MOUNTED, LOCKABLE, COMPA RTMENTED STEEL BOX OR CABINET. ARRANGE FOR WALL MOUNTING. 2.7 IDENTIFICATION A. SERVICE EQUIPMENT LABEL: NRTL LABELED FOR USE AS SERVICE EQUIPMENT FOR SWITCHBOARDS WITH ONE OR MORE SERVICE DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES. PART 3-EXECUTION 3.1 EXAMINATION A. RECEIVE, INSPECT, HANDLE, AND STORE SWITCHBOARDS ACCORDING TO NEMA PB 2.1. B. EXAMINE SWITCHBOARDS BEFORE INSTALLATION. REJECT SWITCHBOARDS THAT ARE MOISTURE DAMAGED OR PHYSICALLY DAMAGED. C. EXAMINE ELEMENTS AND SURFACES TO RECEIVE SWITCHBOARDS FOR COMPLIANCE WITH INSTALLATION TOLERANCES AND OTHER CONDITIONS AFFECTING PERFORMANCE OF THE WORK. D. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. SECTION 262413 - SWITCHBOARDS CONTINUED 3.2 INSTALLATION A. INSTALL SWITCHBOARDS AND ACCESSORIES ACCORDING TO NEMA PB 2.1. B. EQUIPMENT MOUNTING: INSTALL SWITCHBOARDS ON CONCRETE BASE, 4-INCH (100-MM) NOMINAL THICKNESS. COMPLY WITH REQUIREMENTS FOR CONCRETE BASE SPECIFIED IN DIVISION 03 SECTION "MISCELLANEOUS CAST -IN -PLACE CONCRETE." 1. INSTALL DOWEL RODS TO CONNECT CONCRETE BASE TO CONCRETE FLOOR. UNLESS OTHERWISE INDICATED, INSTALL DOWEL RODS ON 18-INCH (450-MM) CENTERS AROUND THE FULL PERIMETER OF CONCRETE BASE, 2. FOR SUPPORTED EQUIPMENT, INSTALL EPDXY -COATED ANCHOR BOLTS THAT EXTEND THROUGH CONCRETE BASE AND ANCHOR INTO STRUCTURAL CONCRETE FLOOR. 3. PLACE AND SECURE ANCHORAGE DEVICES, USE SETTING DRAWINGS, TEMPLATES, DIAGRAMS, INSTRUCTIONS, AND DIRECTIONS FURNISHED WITH ITEMS TO BE EMBEDDED. 4. INSTALL ANCHOR BOLTS TO ELEVATIONS REQUIRED FOR PROPER ATTACHMENTTO SWITCHBOARDS. C. TEMPORARY LIFTING PROVISIONS: REMOVE TEMPORARY LIFTING EYES, CHANNELS, AND BRACKETS AND TEMPORARY BLOCKING OF MOVING PARTS FROM SWITCHBOARD UNITS AND COMPONENTS. D. OPERATING INSTRUCTIONS: FRAME AND MOUNT THE PRINTED BASIC OPERATING INSTRUCTIONS FOR SWITCHBOARDS, INCLUDING EMERGENCY PROCEDURES. FABRICATE FRAME OF FINISHED WOOD OR METAL AND COVER INSTRUCTIONS WITH CLEAR ACRYLIC PLASTIC. MOUNT ON FRONT OF SWITCHBOARDS. E. INSTALL FILLER PLATES IN UNUSED SPACES OF PANEL -MOUNTED SECTIONS. F. INSTALL OVERCURRENT PROTECTIVE DEVICES, SURGE PROTECTION DEVICES, AND INSTRUMENTATION. 1. SET FIELD -ADJUSTABLE CIRCUIT -BREAKER TRIP RANGES WITH A REASONABLE ATTEMPT TO PROVIDE DEVICE OVERCURRENT COORDINATION. G. INSTALL SPARE -FUSE CABINET. H. COMPLY WITH NECA 1. 3.3 CONNECTIONS A. COMPLY WITH REQUIREMENTS FOR TERMINATING FEEDER BUS SPECIFIED IN DIVISION 26 SECTION "ENCLOSED BUS ASSEMBLIES." DRAWINGS INDICATE GENERAL ARRANGEMENT OF BUS, FITTINGS, AND SPECIALTIES. 3.4 IDENTIFICATION A. IDENTIFY FIELD -INSTALLED CONDUCTORS, INTERCONNECTING WIRING, AND COMPONENTS; PROVIDE WARNING SIGNS COMPLYING WITH REQUIREMENTS FOR IDENTIFICATION SPECIFIED IN DIVISION 26 SECTION "IDENTIFICATION FOR ELECTRICAL SYSTEMS." B. SWITCHBOARD NAMEPLATES: LABEL EACH SWITCHBOARD COMPARTMENT WITH A NAMEPLATE COMPLYING WITH REQUIREMENTS FOR IDENTIFICATION SPECIFIED IN DIVISION 26 SECTION "IDENTIFICATION FOR ELECTRICAL SYSTEMS." C. DEVICE NAMEPLATES: LABEL EACH DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICE AND EACH METER AND CONTROL DEVICE MOUNTED IN COMPARTMENT DOORS WITH A NAMEPLATE COMPLYING WITH REQUIREMENTS FOR IDENTIFICATION SPECIFIED IN DIVISION 26 SECTION "IDENTIFICATION FOR ELECTRICAL SYSTEMS." 3.5 FIELD QUALITY CONTROL A. PERFORM TESTS AND INSPECTIONS. 1. MANUFACTURER'S FIELD SERVICE: ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO INSPECT COMPONENTS, ASSEMBLIES, AND EQUIPMENT INSTALLATIONS, INCLUDING CONNECTIONS, AND TO ASSIST IN TESTING. B. ACCEPTANCE TESTING PREPARATION: 1. TEST INSULATION RESISTAN COMPONENT, CONNECTING SUPPLY FEEDER AND CONTROL CIRCUIT. SRESISTANCE FOR EACH SWITCHBOARD BUS, CO 0 , 2. TEST CONTINUITY OF EACH CIRCUIT, C. TESTS AND INSPECTIONS: 1. PERFORM EACH VISUAL AND MECHANICAL INSPECTION AND ELECTRICAL TEST STATED IN NETA ACCEPTANCE TESTING SPECIFICATION. CERTIFY COMPLIANCE WITH TEST PARAMETERS. 2. CORRECT MALFUNCTIONING UNITS ON -SITE, WHERE POSSIBLE, AND RETEST TO DEMONSTRATE COMPLIANCE; OTHERWISE, REPLACE WITH NEW UNITS AND RETEST. 3. PERFORM THE FOLLOWING INFRARED SCAN TESTS AND INSPECTIONS AND PREPARE REPORTS: a. INITIAL INFRARED SCANNING: AFTER SUBSTANTIAL COMPLETION, BUT NOT MORE THAN 60 DAYS AFTER FINAL ACCEPTANCE, PERFORM AN INFRARED SCAN OF EACH SWITCHBOARD. REMOVE FRONT PANELS SO JOINTS AND CONNECTIONS ARE ACCESSIBLE TO PORTABLE SCANNER. b. FOLLOW-UP INFRARED SCANNING: PERFORM AN ADDITIONAL FOLLOW-UP INFRARED SCAN OF EACH SWITCHBOARD 11 MONTHS AFTER DATE OF SUBSTANTIAL COMPLETION, C. INSTRUMENTS AND EQUIPMENT: 1) USE AN INFRARED SCANNING DEVICE DESIGNED TO MEASURE TEMPERATURE OR TO DETECT SIGNIFICANT DEVIATIONS FROM NORMAL VALUES. PROVIDE CALIBRATION RECORD FOR DEVICE. 4. TEST AND ADJUST CONTROLS, REMOTE MONITORING, AND SAFETIES. REPLACE DAMAGED AND MALFUNCTIONING CONTROLS AND EQUIPMENT. D. SWITCHBOARD WILL BE CONSIDERED DEFECTIVE IF IT DOES NOT PASS TESTS AND INSPECTIONS. E. PREPARE TEST AND INSPECTION REPORTS, INCLUDING A CERTIFIED REPORT THAT IDENTIFIES SWITCHBOARDS INCLUDED AND THAT DESCRIBES SCANNING RESULTS. INCLUDE NOTATION OF DEFICIENCIES DETECTED, REMEDIAL ACTION TAKEN, AND OBSERVATIONS AFTER REMEDIAL ACTION. 3.6 ADJUSTING A. ADJUST MOVING PARTS AND OPERABLE COMPONENTS TO FUNCTION SMOOTHLY, AND LUBRICATE AS RECOMMENDED BY MANUFACTURER, B. SET FIELD -ADJUSTABLE CIRCUIT -BREAKER TRIP RANGES WITH A REASONABLE ATTEMPT TO PROVIDE DEVICE OVERCURRENT COORDINATION. 3.7 PROTECTION A. TEMPORARY HEATING: APPLY TEMPORARY HEAT, TO MAINTAIN TEMPERATURE ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS, UNTIL SWITCHBOARD IS READY TO BE ENERGIZED AND PLACED INTO SERVICE. 3.8 DEMONSTRATION A. TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN SWITCHBOARDS, OVERCURRENT PROTECTIVE DEVICES, INSTRUMENTATION, AND ACCESSORIES, AND TO USE AND REPROGRAM MICROPROCESSOR -BASED TRIP, MONITORING, AND COMMUNICATION UNITS. END OF SECTION 262413 SECTION 262416-PANELBOARDS PART 1-GENERAL 1.1 SUMMARY A. SECTION INCLUDES DISTRIBUTION PANELBOARDS AND BRANCH -CIRCUIT PANELBOARDS. 1.2 SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. B. SHOP DRAWINGS: FOR EACH PANELBOARD AND RELATED EQUIPMENT. 1. INCLUDE DIMENSIONED PLANS, ELEVATIONS, SECTIONS, AND DETAILS. SHOW TABULATIONS OF INSTALLED DEVICES, EQUIPMENT FEATURES, AND RATINGS. 2. DETAIL ENCLOSURE TYPES AND DETAILS FOR TYPES OTHER THAN NEMA 250, TYPE 1. 3. DETAIL BUS CONFIGURATION, CURRENT, AND VOLTAGE RATINGS. 4. SHORT-CIRCUIT CURRENT RATING OF PANELBOARDS AND OVERCURRENT PROTECTIVE DEVICES. 1.3 QUALITY ASSURANCE A. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. B. COMPLY WITH NEMA PB 1. C. COMPLY WITH NFPA 70. 1.4 WARRANTY A. WARRANTY PERIOD: MINIMUM FIVE YEARS FROM DATE OF SUBSTANTIAL COMPLETION. PART2-PRODUCTS 2.1 GENERAL REQUIREMENTS FOR PANELBOARDS A. ENCLOSURES; SURFACE -MOUNTED CABINETS. 1. RATED FOR ENVIRONMENTAL CONDITIONS AT INSTALLED LOCATION. a. OUTDOOR LOCATIONS: NEMA 250, TYPE 3R. 2. HINGED FRONT COVER: ENTIRE FRONT TRIM HINGED TO BOX AND WITH STANDARD DOOR WITHIN HINGED TRIM COVER. 3. DIRECTORY CARD: INSIDE PANELBOARD DOOR, MOUNTED IN TRANSPARENT CARD HOLDER. B. INCOMING MAINS LOCATION: TOP AND BOTTOM. C. PHASE, NEUTRAL, AND GROUND BUSES: HARD -DRAWN COPPER, 98 PERCENT CONDUCTIVITY. D. CONDUCTOR CONNECTORS: SUITABLE FOR USE WITH CONDUCTOR MATERIAL AND SIZES. 1. MATERIAL: HARD -DRAWN COPPER, 98 PERCENT CONDUCTIVITY. 2. MAIN AND NEUTRAL LUGS: MECHANICAL TYPE. 3. GROUND LUGS AND BUS CONFIGURED TERMINATORS: COMPRESSION TYPE. E. SERVICE EQUIPMENT LABEL: NRTL LABELED FOR USE AS SERVICE EQUIPMENT FOR PANELBOARDS WITH ONE OR MORE MAIN SERVICE DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES. F. FUTURE DEVICES: MOUNTING BRACKETS, BUS CONNECTIONS, FILLER PLATES, AND NECESSARY APPURTENANCES REQUIRED FOR FUTURE INSTALLATION OF DEVICES. G. PANELBOARD SHORT-CIRCUIT CURRENT RATING: FULLY RATED TO INTERRUPT SYMMETRICAL SHORT-CIRCUIT CURRENT AVAILABLE AT TERMINALS. 2.2 DISTRIBUTION PANELBOARDS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS: 1. EATON ELECTRICAL INC.; CUTLER -HAMMER BUSINESS UNIT. 2. GENERAL ELECTRIC COMPANY; GE CONSUMER & INDUSTRIAL - ELECTRICAL DISTRIBUTION. 3. SIEMENS ENERGY & AUTOMATION, INC. 4. SQUARE D; A BRAND OF SCHNEIDER ELECTRIC. B. PANELBOARDS: NEMA PB 1, POWER AND FEEDER DISTRIBUTION TYPE. C. DOORS: SECURED WITH VAULT -TYPE LATCH WITH TUMBLER LOCK; KEYED ALIKE. D. MAINS: CIRCUIT BREAKER. E. BRANCH OVERCURRENT PROTECTIVE DEVICES: FOR CIRCUIT -BREAKER FRAME SIZES 125 AAND SMALLER: BOLT -ON CIRCUIT BREAKERS. F. BRANCH OVERCURRENT PROTECTIVE DEVICES: FOR CIRCUIT -BREAKER FRAME SIZES LARGER THAN 125 A: BOLT -ON CIRCUIT BREAKERS; PLUG-IN CIRCUIT BREAKERS WHERE INDIVIDUAL POSITIVE -LOCKING DEVICE REQUIRES MECHANICAL RELEASE FOR REMOVAL, 2.3 BRANCH -CIRCUIT PANELBOARDS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. EATON ELECTRICAL INC.; CUTLER -HAMMER BUSINESS UNIT. 2. GENERAL ELECTRIC COMPANY; GE CONSUMER & INDUSTRIAL - ELECTRICAL DISTRIBUTION. 3. SIEMENS ENERGY & AUTOMATION, INC. 4. SQUARE D; A BRAND OF SCHNEIDER ELECTRIC. B. PANELBOARDS: NEMA PB 1, BRANCH -CIRCUIT TYPE. C. MAINS: CIRCUIT BREAKER OR LUGS ONLY. D. BRANCH OVERCURRENT PROTECTIVE DEVICES: BOLT -ON CIRCUIT BREAKERS, REPLACEABLE WITHOUT DISTURBING ADJACENT UNITS. E. DOORS: CONCEALED HINGES; SECURED WITH FLUSH LATCH WITH TUMBLER LOCK; KEYED ALIKE. SECTION 262416 - PANELBOARDS CONTINUED 2.4 DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING' 1. EATON ELECTRICAL INC.; CUTLER -HAMMER BUSINESS UNIT. 2. GENERAL ELECTRIC COMPANY; GE CONSUMER & INDUSTRIAL - ELECTRICAL DISTRIBUTION. 3. SIEMENS ENERGY & AUTOMATION, INC. 4. SQUARE D; A BRAND OF SCHNEIDER ELECTRIC. B. MOLDED -CASE CIRCUIT BREAKER (MCCB): COMPLY WITH UL 489, WITH INTERRUPTING CAPACITY TO MEET AVAILABLE FAULT CURRENTS. 1. THERMAL -MAGNETIC CIRCUIT BREAKERS: INVERSE TIME -CURRENT ELEMENT FOR LOW-LEVEL OVERLOADS, AND INSTANTANEOUS MAGNETIC TRIP ELEMENT FOR SHORT CIRCUITS. ADJUSTABLE MAGNETIC TRIP SETTING FOR CIRCUIT -BREAKER FRAME SIZES 250 A AND LARGER. 2. ADJUSTABLE INSTANTANEOUS -TRIP CIRCUIT BREAKERS: MAGNETIC TRIP ELEMENT WITH FRONT -MOUNTED, FIELD -ADJUSTABLE TRIP SETTING. 3. GFCI CIRCUIT BREAKERS: SINGLE- AND TWO -POLE CONFIGURATIONS WITH CLASS A GROUND -FAULT PROTECTION (6-MA TRIP). 4. MOLDED -CASE CIRCUIT -BREAKER (MCCB) FEATURES AND ACCESSORIES: a. STANDARD FRAME SIZES, TRIP RATINGS, AND NUMBER OF POLES. b. LUGS: MECHANICAL STYLE, SUITABLE FOR NUMBER, SIZE, TRIP RATINGS, AND CONDUCTOR MATERIALS. C. APPLICATION LISTING: APPROPRIATE FOR APPLICATION; TYPE SWD FOR SWITCHING FLUORESCENT LIGHTING LOADS; TYPE HID FOR FEEDING FLUORESCENT AND HIGH -INTENSITY DISCHARGE (HID) LIGHTING CIRCUITS. d. SHUNT TRIP: 24-V TRIP COIL ENERGIZED FROM SEPARATE CIRCUIT, SET TO TRIP AT 75 PERCENT OF RATED VOLTAGE. B. HANDLE PADLOCKING DEVICE: FIXED ATTACHMENT, FOR LOCKING CIRCUIT -BREAKER HANDLE IN ON OR OFF POSITION. f. HANDLE CLAMP: LOOSE ATTACHMENT, FOR HOLDING CIRCUIT -BREAKER HANDLE IN ON POSITION. 011:0011"16111 )II161 3.1 INSTALLATION A. RECEIVE, INSPECT, HANDLE, STORE AND INSTALL PANELBOARDS AND ACCESSORIES ACCORDING TO NEMA PB 1.1. B. MOUNT TOP OF TRIM 72 INCHES ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED. C. MOUNT PANELBOARD CABINET PLUMB AND RIGID WITHOUT DISTORTION OF BOX. MOUNT RECESSED PANELBOARDS WITH FRONTS UNIFORMLY FLUSH WITH WALL FINISH AND MATING WITH BACK BOX. D. INSTALL OVERCURRENT PROTECTIVE DEVICES AND CONTROLLERS NOT ALREADY FACTORY INSTALLED. 1. SET FIELD -ADJUSTABLE, CIRCUIT -BREAKER TRIP RANGES WITH A REASONABLE ATTEMPT TO PROVIDE DEVICE OVERCURRENT COORDINATION, E. INSTALL FILLER PLATES IN UNUSED SPACES. F. ARRANGE CONDUCTORS IN GUTTERS INTO GROUPS AND BUNDLE AND WRAP WITH WIRE TIES. G. COMPLY WITH NECA 1. 3.2 IDENTIFICATION A. IDENTIFY FIELD -INSTALLED CONDUCTORS, INTERCONNECTING WIRING, AND COMPONENTS; PROVIDE WARNING SIGNS COMPLYING WITH DIVISION 26 SECTION "IDENTIFICATION FOR ELECTRICAL SYSTEMS." B. CREATE A DIRECTORY TO INDICATE INSTALLED CIRCUIT LOADS AND INCORPORATING OWNER'S FINAL ROOM DESIGNATIONS, OBTAIN APPROVAL BEFORE INSTALLING. USE A COMPUTER OR TYPEWRITER TO CREATE DIRECTORY; HANDWRITTEN DIRECTORIES ARE NOT ACCEPTABLE, C. PANELBOARD NAMEPLATES: LABEL EACH PANELBOARD WITH A NAMEPLATE COMPLYING WITH REQUIREMENTS FOR IDENTIFICATION SPECIFIED IN DIVISION 26 SECTION "IDENTIFICATION FOR ELECTRICAL SYSTEMS." D. DEVICE NAMEPLATES: LABEL EACH BRANCH CIRCUIT DEVICE IN DISTRIBUTION PANELBOARDS WITH A NAMEPLATE COMPLYING WITH REQUIREMENTS FOR IDENTIFICATION SPECIFIED IN DIVISION 26 SECTION "IDENTIFICATION FOR ELECTRICAL SYSTEMS." 3.3 FIELD QUALITY CONTROL A. PERFORM TESTS AND INSPECTIONS. B. ACCEPTANCE TESTING PREPARATION: 1. TEST INSULATION RESISTANCE FOR EACH PANELBOARD BUS, COMPONENT, CONNECTING SUPPLY, FEEDER, AND CONTROL CIRCUIT. 2. TEST CONTINUITY OF EACH CIRCUIT. C. TESTS AND INSPECTIONS: 1. PERFORM EACH VISUAL AND MECHANICAL INSPECTION AND ELECTRICAL TEST STATED IN NETA ACCEPTANCE TESTING SPECIFICATION. CERTIFY COMPLIANCE WITH TEST PARAMETERS. 2. CORRECT MALFUNCTIONING UNITS ON -SITE, WHERE POSSIBLE, AND RETEST TO DEMONSTRATE COMPLIANCE; OTHERWISE, REPLACE WITH NEW UNITS AND RETEST. D. PANELBOARDS WILL BE CONSIDERED DEFECTIVE IF THEY DO NOT PASS TESTS AND INSPECTIONS. E. PREPARE TEST AND INSPECTION REPORTS, INCLUDING A CERTIFIED REPORT THAT IDENTIFIES PANELBOARDS INCLUDED AND THAT DESCRIBES SCANNING RESULTS. INCLUDE NOTATION OF DEFICIENCIES DETECTED, REMEDIAL ACTION TAKEN, AND OBSERVATIONS AFTER REMEDIAL ACTION. END OF SECTION 262416 SECTION 262726 - WIRING DEVICES PART 1-GENERAL 1.1 SECTION REQUIREMENTS A. SUBMITTALS: PRODUCT DATA. PART2-PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. B. COMPLY WITH NFPA 70. 2.2 COMMERCIAL -GRADE DEVICES A. DEVICE COLOR: 1. WIRING DEVICES CONNECTED TO NORMAL POWER SYSTEM: IVORY UNLESS OTHERWISE INDICATED OR REQUIRED BY NFPA 70 OR DEVICE LISTING. B. CONVENIENCE RECEPTACLES: NEMA WD 1, NEMA WD 6, CONFIGURATION 5-20R, AND UL 498. 1. PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE ONE OF THE FOLLOWING: a. COOPER; 5351 (SINGLE), CR5362 (DUPLEX). b. HUBBELL; HBL5351 (SINGLE), HBL5352 (DUPLEX). C. LEVITON; 5891 (SINGLE), 5352 (DUPLEX). d. PASS & SEYMOUR; 5361 (SINGLE), 5362 (DUPLEX). C. DUPLEX GFCI CONVENIENCE RECEPTACLES: 125 V, 20 A, STRAIGHT BLADE, NON -FEED -THROUGH TYPE. NEMA WD 1, NEMA WD 6, UL 498, AND UL 943, CLASS A, AND INCLUDE INDICATOR LIGHT THAT IS LIGHTED WHEN DEVICE IS TRIPPED. 1. PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS FROM ONE OF THE FOLLOWING: a. COOPER b. HUBBELL C. PASS & SEYMOUR d. LEVITON D. 'TOGGLE SWITCHES: NEMA WD 1 AND UL 20. SINGLE -POLE, 120/277 V, 20 A. 1. PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCT FOR THE POLES INDICATED FROM ONE OF THE FOLLOWING: a. COOPER b. HUBBELL C. LEVITON d. PASS & SEYMOUR E. MOMENTARY CONTACT TOGGLE SWITCHES: NEMA WD 1 AND UL 20. SINGLE -POLE, DOUBLE -THROW, MOMENTARY CONTACT, CENTER -OFF SWITCHES, 120/277 V, 20 A; FOR USE WITH MECHANICALLY HELD LIGHTING CONTACTORS. 1. PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS FROM ONE OF THE FOLLOWING: a. COOPER. b. HUBBELL. C. PASS& SEYMOUR d. LEVITON F. PILOT -LIGHT SWITCHES, 20 A: SINGLE POLE, WITH NEON -LIGHTED HANDLE, ILLUMINATED WHEN SWITCH IS "OFF" 1. PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE ONE OF THE FOLLOWING: a. COOPER; AH1221 PL FOR 120 AND 277 V. b. HUBBELL; HBL1201PL FOR 120 AND 277 V. C. LEVITON; 1221-LH1. d. PASS & SEYMOUR; PS20ACIRPL FOR 120 V, PS20AGI RPL7 FOR 277 V. 2.3 WALL PLATES A. WALL PLATES, FINISHED AREAS: SMOOTH, HIGH -IMPACT THERMOPLASTIC FASTENED WITH METAL SCREWS HAVING HEADS MATCHING PLATE COLOR. B. WALL PLATES, UNFINISHED AREAS: GALVANIZED STEEL WITH METAL SCREWS. C. WALL PLATES, DAMP LOCATIONS: THERMOPLASTIC WITH SPRING -LOADED LIFT COVER, AND LISTED AND LABELED FOR USE IN WET LOCATIONS. PART 3 - EXECUTION 3.1 INSTALLATION A. COMPLY WITH NECA 1, INCLUDING THE MOUNTING HEIGHTS LISTED IN THAT STANDARD, UNLESS OTHERWISE NOTED. EXTRA -DEEP PLATES. REPAIR WALL FINISHES AND REMOUNT OUTLET BOXES WHEN STANDARD DEVICE PLATES DO NOT FIT B. DO NOT USE OVERSIZED OR FLUSH OR DO NOT COVER ROUGH WALL OPENING. C. SELECT DEVICE COLORS AND WALL PLATES AS FOLLOWS: 1. FOR PLASTIC COVERS, MATCH DEVICE COLOR. D. MOUNT DEVICES FLUSH, WITH LONG DIMENSION VERTICAL, AND GROUNDING TERMINAL OF RECEPTACLES ON TOP UNLESS OTHERWISE INDICATED. GROUP ADJACENT DEVICES UNDER SINGLE, MULTIGANG WALL PLATES. IgN1I61961xH111 NIN-1'XF'T] Sims Wilkerson Cartier Engineering, Inc. 12124 High Teah Avenue - Suite, 200 Orlando, Florida 32817 (407)380-0400 FAX (407)380-5900 FL. CERT. OF AUTH. NO. 6106 O GAY A. IW,IQ&90N, PE. 63167 O K. LE J. CAR [Mi PE. 53269 • AD f S. LEAINR, P.E. 77010 • JEFF.A. R1R U: N, P.E. 65629 • SA RTL R. AI ANDER, P.E. 5542 14001 \%L R.IAL�c//��i %C S� 931 SAD'• STATE OF %4L,� ��FS•ZORION 'N�°��� QNL 11A1 l I11 ii ' J L L.L U v ED � LID J _ Ir- O LiJ O IN 1 U) 0 LL J CY) z O 1 Q ® > p I- U U C:U � �j as L.L CU � U W W JQ ALL/. w ��(1/�- VJ �'4-/^-; ''+/^;+ VJ Z VJ O_� L C-)� W M O IT � W SECTION 262200 - LOW -VOLTAGE TRANSFORMERS PART 1-GENERAL 1.1 RELATED DOCUMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. 1.2 SUMMARY A. THIS SECTION INCLUDES THE FOLLOWING TYPES OF DRY -TYPE TRANSFORMERS RATED 600 V AND LESS, WITH CAPACITIES UP TO 1000 KVA: 1. DISTRIBUTION TRANSFORMERS. 1.3 ACTION SUBMITTALS A. PRODUCT DATA: INCLUDE RATED NAMEPLATE DATA, CAPACITIES, WEIGHTS, DIMENSIONS, MINIMUM CLEARANCES, INSTALLED DEVICES AND FEATURES, AND PERFORMANCE FOR EACH TYPE AND SIZE OF TRANSFORMER INDICATED, B. SHOP DRAWINGS: DETAIL EQUIPMENT ASSEMBLIES AND INDICATE DIMENSIONS, WEIGHTS, LOADS, REQUIRED CLEARANCES, METHOD OF FIELD ASSEMBLY, COMPONENTS, AND LOCATION AND SIZE OF EACH FIELD CONNECTION. 1. WIRING DIAGRAMS: POWER, SIGNAL, AND CONTROL WIRING. 1.4 INFORMATIONAL SUBMITTALS A. QUALIFICATION DATA: FOR TESTING AGENCY, B. SOURCE QUALITY -CONTROL TEST REPORTS. C. FIELD QUALITY -CONTROL TEST REPORTS. 1.5 CLOSEOUT SUBMITTALS A. OPERATION AND MAINTENANCE DATA: FOR TRANSFORMERS TO INCLUDE IN EMERGENCY, OPERATION, AND MAINTENANCE MANUALS. 1.6 QUALITY ASSURANCE A. TESTING AGENCY QUALIFICATIONS: AN INDEPENDENT AGENCY, WITH THE EXPERIENCE AND CAPABILITY TO CONDUCT THE TESTING INDICATED, THAT IS A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL) AS DEFINED BY OSHA IN 29 CFR 1910.7. B. SOURCE LIMITATIONS: OBTAIN EACH TRANSFORMER TYPE THROUGH ONE SOURCE FROM A SINGLE MANUFACTURER. C. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE. D. COMPLY WITH IEEE C57.12.91, "TEST CODE FOR DRY -TYPE DISTRIBUTION AND POWER TRANSFORMERS." 1.7 DELIVERY, STORAGE, AND HANDLING A. TEMPORARY HEATING: APPLY TEMPORARY HEAT ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS WITHIN THE ENCLOSURE OF EACH VENTILATED -TYPE UNIT, THROUGHOUT PERIODS DURING WHICH EQUIPMENT IS NOT ENERGIZED AND WHEN TRANSFORMER IS NOT IN A SPACE THAT IS CONTINUOUSLY UNDER NORMAL CONTROL OF TEMPERATURE AND HUMIDITY. 1.8 COORDINATION A. COORDINATE SIZE AND LOCATION OF CONCRETE BASES WITH ACTUAL TRANSFORMER PROVIDED. CAST ANCHOR -BOLT INSERTS INTO BASES. CONCRETE, REINFORCEMENT, AND FORMWORK REQUIREMENTS ARE SPECIFIED IN DIVISION 03. B. COORDINATE INSTALLATION OF WALL -MOUNTING AND STRUCTURE -HANGING SUPPORTS WITH ACTUAL TRANSFORMER PROVIDED. PART2-PRODUCTS 2.1 MANUFACTURERS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. EATON ELECTRICAL INC.; CUTLER -HAMMER PRODUCTS. 2. GENERAL ELECTRIC COMPANY. 3. SIEMENS ENERGY & AUTOMATION, INC. 4. SQUARE D; SCHNEIDER ELECTRIC, 2.2 GENERAL TRANSFORMER REQUIREMENTS A. DESCRIPTION: FACTORY -ASSEMBLED AND -TESTED, AIR-COOLED UNITS FOR 60-HZ SERVICE. B. CORES: GRAIN -ORIENTED, NON -AGING SILICON STEEL. C. COILS: CONTINUOUS WINDINGS WITHOUT SPLICES EXCEPT FOR TAPS. 1. INTERNAL COIL CONNECTIONS: BRAZED OR PRESSURE TYPE. 2. COIL MATERIAL: COPPER. 2.3 DISTRIBUTION TRANSFORMERS A. COMPLY WITH NEMA ST 20, AND LISTAND LABEL AS COMPLYING WITH UL 1561. B. CORES: ONE LEG PER PHASE. C. ENCLOSURE: VENTILATED, NEMA 250, TYPE 2. 1. CORE AND COIL SHALL BE ENCAPSULATED WITHIN RESIN COMPOUND, SEALING OUT MOISTURE AND AIR. D. TRANSFORMER ENCLOSURE FINISH: COMPLY WITH NEMA 250. 1. FINISH COLOR: GRAY, E. TAPS FOR TRANSFORMERS SMALLER THAN 3 KVA: NONE. F. TAPS FOR TRANSFORMERS 7.5 TO 24 KVA: ONE 5 PERCENT TAP ABOVE AND ONE 5 PERCENT TAP BELOW NORMAL FULL CAPACITY. G. TAPS FOR TRANSFORMERS 25 KVA AND LARGER: TWO 2.5 PERCENT TAPS ABOVE AND TWO 2.5 PERCENT TAPS BELOW NORMAL FULL CAPACITY. H. INSULATION CLASS: 220 DEG C, UL-COMPONENT-RECOGNIZED INSULATION SYSTEM WITH A MAXIMUM OF 150 DEG C RISE ABOVE 40 DEG C AMBIENT TEMPERATURE. I. ENERGY EFFICIENCY FOR TRANSFORMERS RATED 15 KVA AND LARGER: 1. COMPLYING WITH NEMA TP 1, CLASS 1 EFFICIENCY LEVELS. 2. TESTED ACCORDING TO NEMA TP 2. J. LOW -SOUND -LEVEL REQUIREMENTS: MINIMUM OF 3 DBA LESS THAN NEMA ST 20 STANDARD SOUND LEVELS WHEN FACTORY TESTED ACCORDING TO IEEE C57.12.91. 2.4 IDENTIFICATION DEVICES A. NAMEPLATES: ENGRAVED, LAMINATED -PLASTIC OR METAL NAMEPLATE FOR EACH DISTRIBUTION TRANSFORMER, MOUNTED WITH CORROSION -RESISTANT SCREWS. NAMEPLATES AND LABEL PRODUCTS ARE SPECIFIED IN DIVISION 26 SECTION "IDENTIFICATION FOR ELECTRICAL SYSTEMS." 2.5 SOURCE QUALITY CONTROL A. TEST AND INSPECT TRANSFORMERS ACCORDING TO IEEE C57.12.91. B. FACTORY SOUND -LEVEL TESTS: CONDUCT SOUND -LEVEL TESTS ON EQUIPMENT FOR THIS PROJECT. PART 3 - EXECUTION 3.1 EXAMINATION A. EXAMINE CONDITIONS FOR COMPLIANCE WITH ENCLOSURE- AND AMBIENT -TEMPERATURE REQUIREMENTS FOR EACH TRANSFORMER. B. VERIFY THAT FIELD MEASUREMENTS ARE AS NEEDED TO MAINTAIN WORKING CLEARANCES REQUIRED BY NFPA 70 AND MANUFACTURER'S WRITTEN INSTRUCTIONS. C. EXAMINE WALLS, FLOORS, ROOFS, AND CONCRETE BASES FOR SUITABLE MOUNTING CONDITIONS WHERE TRANSFORMERS WILL BE INSTALLED. D. VERIFY THAT GROUND CONNECTIONS ARE IN PLACE AND REQUIREMENTS IN DIVISION 26 SECTION "GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS" HAVE BEEN MET. MAXIMUM GROUND RESISTANCE SHALL BE 5 OHMS AT LOCATION OF TRANSFORMER. E. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED, 3.2 INSTALLATION A. CONSTRUCT CONCRETE BASES AND ANCHOR FLOOR -MOUNTING TRANSFORMERS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS AND REQUIREMENTS IN DIVISION 26 SECTION "HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS." 3.3 CONNECTIONS A. GROUND EQUIPMENT ACCORDING TO DIVISION 26 SECTION "GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS." B. CONNECT WIRING ACCORDING TO DIVISION 26 SECTION "LOW -VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES." 3.4 FIELD QUALITY CONTROL A. TESTING AGENCY: ENGAGE A QUALIFIED TESTING AGENCY TO PERFORM TESTS AND INSPECTIONS AND PREPARE TEST REPORTS. B. MANUFACTURER'S FIELD SERVICE: ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO INSPECT, TEST, AND ADJUST COMPONENTS, ASSEMBLIES, AND EQUIPMENT INSTALLATIONS, INCLUDING CONNECTIONS. REPORT RESULTS IN WRITING. C. PERFORM TESTS AND INSPECTIONS AND PREPARE TEST REPORTS. 1. MANUFACTURER'S FIELD SERVICE: ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO INSPECT COMPONENTS, ASSEMBLIES, AND EQUIPMENT INSTALLATIONS, INCLUDING CONNECTIONS, AND TO ASSIST IN TESTING. D. TESTS AND INSPECTIONS: 1. PERFORM EACH VISUAL AND MECHANICAL INSPECTION AND ELECTRICAL TEST STATED IN NETA ACCEPTANCE TESTING SPECIFICATION. CERTIFY COMPLIANCE WITH TEST PARAMETERS. E. REMOVE AND REPLACE UNITS THAT DO NOT PASS TESTS OR INSPECTIONS AND RETEST AS SPECIFIED ABOVE. F. TEST LABELING: ON COMPLETION OF SATISFACTORY TESTING OF EACH UNIT, ATTACH A DATED AND SIGNED "SATISFACTORY TEST" LABEL TO TESTED COMPONENT, 3.5 ADJUSTING A. RECORD TRANSFORMER SECONDARY VOLTAGE AT EACH UNIT FOR AT LEAST 48 HOURS OF TYPICAL OCCUPANCY PERIOD, ADJUST TRANSFORMER TAPS TO PROVIDE OPTIMUM VOLTAGE CONDITIONS AT SECONDARY TERMINALS. OPTIMUM IS DEFINED AS NOT EXCEEDING NAMEPLATE VOLTAGE PLUS 10 PERCENT AND NOT BEING LOWER THAN NAMEPLATE VOLTAGE MINUS 3 PERCENT AT MAXIMUM LOAD CONDITIONS. SUBMIT RECORDING AND TAP SETTINGS AS TEST RESULTS. B. OUTPUT SETTINGS REPORT: PREPARE A WRITTEN REPORT RECORDING OUTPUT VOLTAGES AND TAP SETTINGS. 3.6 CLEANING A. VACUUM DIRT AND DEBRIS; DO NOT USE COMPRESSED AIR TO ASSIST IN CLEANING. END OF SECTION 262200 SECTION 262813 - FUSES SECTION 264313 - SURGE PROTECTION DEVICES PART 1-GENERAL PART 1-GENERAL 1.1 SECTION REQUIREMENTS 1A SECTION REQUIREMENTS 1. SUBMITTALS: A. SUBMITTALS: PRODUCT DATA. A. B. COMPLY WITH IEEE C62.41.2 AND TEST DEVICES ACCORDING TO IEEE C62.45. 1. PRODUCT DATA. 2. MAINTENANCE MATERIAL SUBMITTALS: QUANTITY EQUAL TO TEN PERCENT OF EACH FUSE TYPE AND SIZE, BUT NO FEWER THAN ONE OF EACH TYPE AND C. COMPLY WITH UL 1449. SIZE. D. CONNECT INTEGRALLY MOUNTED SURGE PROTECTION DEVICES ACCORDING TO DIVISION 26 SECTION "SWITCHBOARDS." PART 2-PRODUCTS PART2-PRODUCTS 2.1 PERFORMANCE REQURRMENTS 2.1 PERFORMANCE REQUIREMENTS Sims Wilkerson Cart'. A. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED A. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED 7 FOR INTENDED LOCATION AND APPLICATION. FOR INTENDED LOCATION AND APPLICATION. Engineering, Inc, B. COMPLY WITH NEMA FU 1 FOR CARTRIDGE FUSES. 2.2 SERVICE ENTRANCE SUPPRESSORS 12124 High Tech Avenue- Suite. 2.2 CARTRIDGE FUSES A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 200 Orlando, Florida 32817 A. CHARACTERISTICS: NEMA FU 1, NONRENEWABLE CARTRIDGE FUSES WITH VOLTAGE RATINGS CONSISTENT WITH CIRCUIT VOLTAGES. 1. ADVANCED PROTECTION TECHNOLOGIES INC. (APT). (407) CERT. FAX H. NO. 6106 0 FL 2. ATLANTIC SCIENTIFIC. CEG, . OF AUTH. NO. 6106 2.3 SPARE -FUSE CABINET 3. CURRENT TECHNOLOGY INC.; DANAHER POWER SOLUTIONS. oGARv a. WEhERsP E. 53269 6) o AYLE 1. CARTIER P.E. 53269 A. CABINET: GRAY, BAKED -ENAMEL FINISH; WALL -MOUNTED, STEEL UNIT WITH FULL-LENGTH, RECESSED PIANO -HINGED DOOR AND KEY -CODED CAM LOCK 4. LEA INTERNATIONAL. aS4 LREV AMF,ID O IEFF A. F�tMMN, P.E. 65629 AND PULL. 5. SURGE SUPPRESSION INCORPORATED awnh n..n001 aa.r..u+ 1. SIZE: ADEQUATE FOR STORAGE OF SPARE FUSES SPECIFIED WITH 15 PERCENT SPARE CAPACITY MINIMUM. B. SURGE PROTECTIVE DEVICES: FIELD -MOUNTED, COMPLYING WITH UL 1449 TYPE 1. 14001 1. COMPLY WITH IEEE C62.41 CATEGORY C, 200-KA SHORT-CIRCUIT CURRENT RATING. PART 3 -EXECUTION 2. MODULAR TYPE WITH THE FOLLOWING FEATURES AND ACCESSORIES: a. LED INDICATOR LIGHTS FOR POWER AND PROTECTION STATUS. 1 FUSE APPLICATIONS C. PEAK SINGLE -IMPULSE SURGE CURRENT RATING: 120 KA PER MODE/240 KA PER PHASE. 3. 3. MOTOR BRANCH CIRCUITS: CLASS RK1, TIME DELAY OR AS REQUIRED BY MANUFACTURER. D. PROTECTION MODES AND UL 1449 VPK FOR GROUNDED WYE CIRCUITS WITH 480Y/277 V, THREE-PHASE, FOUR -WIRE CIRCUITS SHALL BE AS FOLLOWS: A.B. OTHER BRANCH CIRCUITS: CLASS RK1, TIME DELAY. 1. LINE TO NEUTRAL: BOO V. C. CONTROL CIRCUITS: CLASS CC, FAST ACTING. 2. LINE TO GROUND: 800 V. 3. NEUTRAL TO GROUND: 800 V. 3.2 INSTALLATION 4. LINE TO LINE: 1200 V. A. INSTALL FUSES SO RATING INFORMATION IS READABLE WITHOUT REMOVING FUSE, B. INSTALL LABELS INDICATING FUSE REPLACEMENT INFORMATION ON INSIDE DOOR OF EACH FUSED SWITCH AND ADJACENT TO EACH FUSE BLOCK AND 2.3 PANELBOARD SUPPRESSORS HOLDER. A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: Q�j VAC E N F tiQ/i i 1. ADVANCED PROTECTION TECHNOLOGIES INC. (APT). C. INSTALL SPARE -FUSE CABINET(S); �% p, 2. ATLANTIC SCIENTIFIC. _ 't /_ END OF SECTION 262813 3. CURRENT TECHNOLOGY INC.; DANAHER POWER SOLUTIONS. - p i * 4. LEA INTERNATIONAL. ?Q`, ST 5. SURGE SUPPRESSION INCORPORATED 5� * c �/ F 40R1D?;•'��' SECTION 282816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS B. SURGE PROTECTIVE DEVICES FIELD -MOUNTED, COMPLYING WITH UL 1449 TYPE 1. // S C�, N� CATEGORY1. COMPLY WITH IEEE C62.41 2. NON -MO ULAR TYPE WITH THEFOLLRATING. OWING FEATURES AND ACCESSORIES /�jO/yp i f��\X�\� 1 PART 1-GENERAL a. LED INDICATOR LIGHTS FOR POWER AND PROTECTION STATUS. 1.1 SECTION REQUIREMENTS C. PEAK SINGLE -IMPULSE SURGE CURRENT RATING: 80 KA PER MODE/160 KA PER PHASE. A. SUBMITTALS: PRODUCT DATA. D. PROTECTION MODES AND UL 1449 SUPPRESSED VOLTAGE RATING FOR GROUNDED WYE CIRCUITS WITH 4BOY/277 V, THREE-PHASE, FOUR -WIRE CIRCUITS SHALL BE AS FOLLOWS: PART 2 -PRODUCTS 1. LINE TO NEUTRAL: 800 V. 2. LINE TO GROUND: 800 V. 2.1 PERFORMANCE REQUIREMNTS 3. NEUTRAL TO GROUND: 800 V. A. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED 4. LINE TO LINE: 1200 V. FOR INTENDED LOCATION AND APPLICATION. E. PROTECTION MODES AND UL 1449 SUPPRESSED VOLTAGE RATING FOR 20BY/120-V, THREE-PHASE, FOUR -WIRE CIRCUITS SHALL BE AS FOLLOWS: 1. LINE TO NEUTRAL: 400 V. 2.2 FUSIBLE AND NONFUSIBLE SWITCHES 2. LINE TO GROUND: 400 V. A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCT BY ONE OF THE FOLLOWING: 3. NEUTRAL TO GROUND: 400 V. 1. EATON ELECTRICAL INC.; CUTLER -HAMMER BUSINESS UNIT. 4. LINE TO LINE: 800 V. 2. GENERAL ELECTRIC COMPANY; GE CONSUMER & INDUSTRIAL - ELECTRICAL DISTRIBUTION. 3. SIEMENS ENERGY &AUTOMATION, INC. 2.4 ENCLOSURES 4. SQUARE D; A BRAND OF SCHNEIDER ELECTRIC A. INDOOR ENCLOSURES: NEMA 250, TYPE 1. B. FUSIBLE SWITCHES, 600 A AND SMALLER: UL 98 AND NEMA KS 1, TYPE HD, THAT ACCOMMODATE SPECIFIED FUSES, AND WITH LOCKABLE HANDLE INTERLOCKED WITH COVER IN CLOSED POSITION. PART 3 - EXECUTION L C. NONFUSIBLE SWITCHES, 800 AAND SMALLER: UL 98 AND NEMA KS 1, TYPE HD, WITH LOCKABLE HANDLE INTERLOCKED WITH COVER INCLOSED POSITION. 3.1 INSTALLATION 2.3 MOLDED -CASE CIRCUIT BREAKERS A. DO NOT ENERGIZE OR CONNECT SERVICE ENTRANCE EQUIPMENT AND PANELBOARDS TO THEIR SOURCES UNTIL SURGE SUPPRESSION DEVICES ARE A. DESCRIPTION: COMPLY WITH UL 489, NEMA AB 1, AND NEMA AB 3, WITH INTERRUPTING CAPACITY TO MEET AVAILABLE FAULT CURRENTS. INSTALLED AND CONNECTED. 1. THERMAL -MAGNETIC CIRCUIT BREAKERS: ADJUSTABLE MAGNETIC TRIP SETTING FOR CIRCUIT -BREAKER FRAME SIZES 250 AAND LARGER. v END OF SECTION 264313 � ~ 2.4 ENCLOSURES A. NEMA AS 1, NEMA KS 1, NEMA 250, AND UL 50, TO COMPLY WITH ENVIRONMENTAL CONDITIONS AT INSTALLED LOCATION. 1. OUTDOOR LOCATIONS: NEMA 250, TYPE 3R. PART 3 - EXECUTION 3.1 INSTALLATION A. INSTALL INDIVIDUAL WALL -MOUNTED SWITCHES AND CIRCUIT BREAKERS WITH TOPS AT UNIFORM HEIGHT UNLESS OTHERWISE INDICATED. B. INSTALL FUSES IN FUSIBLE DEVICES. C. COMPLY WITH NECA 1. 3.2 FIELD QUALITY CONTROL A. PERFORM THE FOLLOWING FIELD TESTS AND INSPECTIONS AND PREPARE TEST REPORTS: 1. PERFORM EACH VISUAL AND MECHANICAL INSPECTION AND ELECTRICAL TEST STATED IN NETA ACCEPTANCE TESTING SPECIFICATION. CERTIFY COMPLIANCE WITH TEST PARAMETERS, END OF SECTION 262810 U I.L U � � u1 -F+ Irl- W i •0) O N C1) J C ' ¢ U C: U LL U U w w J Q J L.L U) v) Z U) OL0_ LL o 0 W 22 `� L0 0 'D U.VJ L '