Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LETTER OF CANCELLATION
CONSTRUCTION CORPORATION CGCOf 30 CONSTRUCTION We do more than building we're buildir Internet: St I August 20, 2019 Mr. William Durden Chief Plans Examiner St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, Florida 34gR? RE: Foundation Permit 1906-0042 Pursuit Boats Plant Expansion Dear Mr. Durden:, Please accept this request to cancel the current Foundi to the main building permit 1907-0579 currently under Should you have any questions regarding this matter rjjLo DWZV7 Sincerely, Douglas Davis President Richard K. Davis Construction Corp. CGC013084 O/U, rkdavis.com kwNron BY Permit # 1906-0042 and apply its approval feel free to contact me. REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY EOCC FILE COPY July 16., 20 1'9 Mr. Gary Stepalavich,.MCP/CFM Building Cade Administrator 2300 Virginiavenu Avenue: - e, Ft. Pierce,, Florida 3498.25,652 ,RE: Pursuit Boats Now #aefifty Plumbing. Fixture �-C .g . . , r Calculation Oft Re Archifect., 9 s. r rp fe q t; N. o., 2'0 181. 4 Dear Mt. 8tegalavidhl As per Florida Plumbing Code; Section 403; 1. f, redistribution of the sexes for the calculation of I women to 80%. men Arid 206/o women, based on Manufact,uringPlant. Letter a, Pursuit Boats; is requesting a fixtures -from 50% men and. 50% data from our existing, Boat. The existing Boat Manufacturing Plant has an,em, lo eou*eo lec04'00, .�M/o-rnen-and.20`%`��I Yq. count _ people,. 3 1 women. This has been. the norm, for our,?l4ht for ver'theipAgtyear§ of operating this Facility. For this reason our employee GO people ype count.:of 4 will, bothe-,same for the New. Facility, 32.0 Men/809/6 and, 80'-women/2 . - 0 As-per,the plumbing -.fixture: calculation shown: on,; load, for, ft. tiew.'fadfity is calculated At 1818 pers( design. of the New,Eacility; we `have only reduced:l from 10 to 7., while the'Meii's has actual been; ins Occupant"Loadj, basedonthaPlumbing"Fixture Co and 70,0 woffien,, 1900 Persons total, with the redisi increase iwt.he total occupant load as calculated by I hope this letter has helped to.justify our rec Plumbing Code,. Section 403.1.1, Exceptibiri. Please feel.freeto contact me if you have any q Sincerely; ncerdly, 'Bruce Thompson Prdsident 1, AMOUR Boats. et AL I 1,,..,see attach copy, the -total. occuDa.nt, 9.09 men and.,9.09 'w6m6h.. Per lumbing I WC & W_ QmOW required plumb '" t p ased .from. 101012 11260 n t, Schedule; w' !ution of th e �tgv a a an aukeXly'll -tv COv 600 redistributio44x%'cs pefte. Florida kS�i l� J Planning & Development Services Department • Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Pursuit Boats Manufacturing Facility Project Address: 3901 St. Lucie Blvd. Ft. Pierce, FL 349I 7 I Permit #: Occupancy Type: F-1 Construction Type: I I B Sprinklered INSTRUCTIONS FOR USE: O This certification must be completed, signed, and sealed b r the design professional of record. • Submit (2) copies for residential, (3) copies for commercia with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete a 1. DESIGN CODE: Florida Building Code Sixth Editior 2. Structure Designed as (check one): X Enclosed 3. Risk Category: I X II _III IV 1 4. Design Wind Velocity 160 mph_X ASD 5. Mean Roof Height 30 ft Roof Pitci I that apply) with 2017 Supplements using ASCE 7-10 _Partially Enclosed _Open )osure Category: B X C D RFD End Zone Width: 15 ft 1/2 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +16 / -39 Zone 2: +16 / -65 Zone 3: +16 / -98 Zone 4: +39 / -42 Zone 5: +39 / -52 Garage: N/A 7. Design Loads: Floor: N/A PSF Roof/Dead: 2 1 PSF Roof/Live: 20 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSIF Fence: N/A PSF Railings: N/A PSF i. 8. Were Shear Walls Considered For Structure? Yes � Not Applicable Explain Why Not: PRE-ENGINEERED METAL BUILDING WITH DIAGONAL WIND BRACING. 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: a. 10. Design Soil Bearing Pressure: 2,500 PSF Soil Test DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attac i comply with the applicable structural portions of the building e County. I also certify that structural elements depicted on thes forces s ecified: 11181110980 Michael Lue It TH °41 O/V PN fiPrint Name - °��•• Signature, D�1, jSaIN9• ©I*40 ngineering, Ir OF Aqlny Name & Ai Revised 12/07/2,08fj • Q' • ♦.0* S/0NA1.'4'k%1k e���1111104, arts Submitte �1-�IAN� ed plans5cifi tietfiidesigned to des currenanc St. Lucie plans provide adequate reJ'�tance to the design Cert #*%%§ Auth. FL Certification#: PE 475201 SI# 1061 - COA # 8662 c., 2030 37th Ave., Vero Beach, FL 32960 dress • Building Permit # Planning & Development Services Department Building & Regulations Division Product Review Affidavit Owners Name RECEIVED JUL 2 5 2019 ST. Lucie County, Permitting Applicant: rl Product - Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment Windows +39/-42 +65/-65 YKK YHS 50 FI FL-14218-R10 IR 5/16" self drilling screws, 3/4" edge, 3 threads penetration past metal structure Mullions Fixed Glass Block Glass Skylights Sliding Glass Doors Swing Type Doors +35/-44 +65/-65 Fleming -Barron Windstorm FL-14237.1 IR 5/16" tapcons, 4 @ jambs, 3 @ head, 3" edge, 1-3/4" min. embedment French Doors _Garage-Doors ---+39/-42 +50A50 /H-Door Corp. 226 FL-742-R9 N/A 3-1/2" x 3-1/2" eguide attached with 1/2" #5 bolts @ 12" o/c Hurricane Protection Roof Ventilation +33/-40 +150/-150 Greenheck Fan EHH-601 D FL-17-0919.05 N/A 1/4" tapcons @ 6" o/c on perimeter angle, 1.5" edge, 1.75" min. embedment Roofing Material +12/42 052.5/-52.5 American Bldgs Co. Standing Seam 360 FL4813.2 N/A No. 12-14 x 1-1/4" self tapping screws w/ 5/8" steel washer & sealing washers --I ® :H Revised 07/22/2014 .M.0 I have reviewe lithe abov I , Qr cladding and I have approved th ' use cture. These products provid Fr •° the wind loads a1r"forces spexqQat code provisions. °.•• °'••°� DOM & Asso tes'�A i ts, P.A. � ° • :� J. D8 ° •' Name: �, .�,. Signature: RHO db 85thony J. Dong3o� A Design Prof: Cert. No. Ar200104SC Date: 0 l ®' 0C RR9e i2456 ; 4 Florida Building:,Code, `Sixth Edition (2),17) -Energy Conservation + EnergyGauge Summit@ Fla/Corti-2017, Effective Date: -Dec 31, 2017 IECC, 2015 - Total Building Perforrrlarice Compliance, Option i. ECEIVED Che,-.k List JUL 2 5 2019 ST., Lucie County, Permitting Applications for compliance with the Florida Building Code, Energy Conservation shall include: MThis Checklist The full compliance report generated by the soft) vare that contains the project summary, compliance summary, certifications a d detailed component compliance reports. The compliance report must include the full input report generated by the software as contigous part of the compliance report. Boxes appropriately checked in the Mandatory ection of the complaince report. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliai Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2[ 7/23/2019 REVIEWED FOR CODE COMPLIANCE RT. LUCIE COUNTY BOCC it Software. Effective Date: Dec 31, 2017 15 - Total Building Performance Compliance Option Page 1 of 26 EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 20151- Total Building Performance Compliance Option 7/23/2019 Page 2 of 26 I Compliancl Summary Component I Design Criteria Result Gross Energy Cost (in $) 18,437.0 19,145.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING No Entry HVAC SYSTEM PASSES PLANT No Entry WATER HEATING SYSTEMS PASSES PIPING SYSTEMS No Entry Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report I I EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 L Total Building Performance Compliance Option 7/23/2019 Page 3 of 26 r CERTIFI I hereby certify that the plans and specifications covered by th`s calculation are in compliance with the Florida Energy Code Prepared By: (�� 3�&U6L6 E-Calcs [us, Inc. Building Official: • Date: July 23, 2019 Date: I certify that this building is in compliance with the FLorida Ene gy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Reg No: Plumbing Designer: Reg No: (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. EnergyGauge Summit® FlalCom-2017. TAM 2017-1.0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 -Total Building Performance Compliance Option 7/23/2019 1 Page 4 of 26 r Project: Pursuit Title: Pursuit Boat Factory Type: Manufacturing Facility (WEA File: FL ST LUCIE ( Total ELECTRICITY(MBtulkWh/$) AREA LIGHTS MISC EQUIPMT PUMPS & MISC SPACE COOL SPACE HEAT VENT FANS Building End Uses I 1)Proposed Credits Applied: None Passing Criteria =19145 Design (including any credits) = 18437 Passing requires Proposed Building cost to be at most 85% of Baseline cost. This Proposed Building is at 81.9% 1,165.30 $18,437 1,165.30 341432 $18,437 88.20 25845 $1,396 182.20 53373 $2,882 0.40 127 $7 589.40 172681 $9,325 138.80 40668 $2,196 166.30 48738 $2, 632 2) Baseline 1,418.30 $22,524 1,418.30 415566 $22,524 257.30 75390 $4,086 182.20 53373 $2,893 0.50 134 $7 622.20 182311 $9,881 29.00 8506 $461 327.10 95852 $5,195 PASSES EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 1 Page 5 of 26 7/23/2019 i External Lighting Compliance .I Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None Project: Pursuit Title: Pursuit Boat Factory Type: Manufacturing Facility (WEA File: FL ST_LUCIE_CO_INTL.tm3) Lighting Controls Compliance Acronym Ashrae Description Area ID (sq.ft) Design Min CP CP Compliance Zone 1 Zone 1 Zone 1 Zone 1 Zone 5 Zone 6 17 Office - Enclosed 3,263 17 Office - Enclosed 352 17 Office - Enclosed 3,193 17 Office - Enclosed 1,512 17 Office - Enclosed 780 31,001 Workshop 9,130 7 2 1 1 7 2 7 1 2 1 8 4 PASSES PASSES PASSES PASSES PASSES PASSES PASSES I I EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 -Total Building Performance Compliance Option Page 6 of 26 Project: Pursuit Title: Pursuit Boat Factory Type: Manufacturing Facility (WEA File: FL_ST_LUCIE_CO_INTL.tm3) System Report Compliance Zone 1 2 ea. 5 ton Split AC Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 2 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air 60000 17.00 13.00 12.90 PASSES Cooled Split System < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 24566 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1800 0.80 0.82 PASSES System -Supply Constant Volume Zone 2 1 ea. 2 ton Split AC Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity I Design Eff Design IPLV Comp- IEff Criteria IPLV Criteria liance Cooling System Air Conditioners Air 24000 17.00 13.00 12.90 PASSES Cooled Split System < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 9826 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 800 0.80 0.82 PASSES System -Supply Constant Volume Zone 3 1 ea. 10 Ton Split AC Condensing Units No. of Units 1 Component Category Capacity Design Eff Design IPLV Comp- �ff Criteria IPLV Criteria I liance Cooling System Condensing Units Air 120000 12.70 10.50 12.20 11.80 PASSES Cooled Heating System Electric Furnace 85027 �.00 1.00 PASSES Air Handling Air Handler (Supply) - 3575 0.60 0.82 PASSES System -Supply Constant Volume Zone 4 1 ea. 6 Ton Split AC I Condensing Units No. of Units I 1 Component Category Capacity Desilgn Eff Design IPLV Comp- Eff Criteria IPLV Criteria I liance EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant So Iftware. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 I Page 7 of 26 Cooling System Condensing Units Air 72000 12.00 10.50 11.80 11.80 PASSES Cooled Heating System Electric Furnace 51000 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 2400 0.80 0.82 PASSES System -Supply Constant Volume Zone 5 2 ea. 5 ton Split AC Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 2 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air 60000 17.00 13.00 12.90 PASSES Cooled Split System < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 24566 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1800 0.80 0.82 PASSES System -Supply Constant Volume Zone 6 2 ea. 10 Ton Split AC Condensing Units No. of Units 2 Component Category Capacity Design Eff Design IPLV Comp- �ff Criteria IPLV Criteria liance Cooling System Condensing Units Air 120000 12.70 10.50 12.20 11.80 PASSES Cooled Heating System Electric Furnace 85027 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 3575 0.60 0.82 PASSES System -Supply Constant Volume PASSES I Plant Complialnce Description Installed Size Design Min DlIpsign Min Category Comp No Eff Eff IPLV IPLV liance I i � None mfl II EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Soft�h�are. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 i Page 8 of 26 I i Project: Pursuit Title: Pursuit Boat Factory Type: Manufacturing Facility (WEA File: FL ST LUCIE CO INTL.tm3) Water Heater Compliance Description Type Category Design Min Design Eff Eff Loss Max Comp Loss liance Water Heater 1 Gas Storage water heater <= 75000 Btu/h; 0.79 0.55 >= 20 Gal PASSES IPASSES Piping System Compliance i, Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compl- [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] lance [F] SF.F] None EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Sc Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Effective Date: Dec 31, 2017 Building Performance Compliance Option 7/23/2019 1 Page 9 of 26 i Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department of Energy and Pacific Northwest National Laboratory. Adopted with permission Topic Section Component Description Yes N/A Exempt 11 1. To be checked by Do" igner or Engineer Insulation C303.2 Envelope Below-g�ade wall insulation installed per manufacturer's instructions. Insulation C303.2 Envelope Slab edge insulation installed per manufacturer's Insulation C303.2 Envelope instructions. Above -grade wall insulation installed per EZ ❑ manufacturer's instructions. Insulation C402.3 Envelope High-alb�do roofs satisfy one of the following: 3-year-aged solar reflectance >= 0.55 and thermal emittance — 0.75 or 3-year-aged solar Fenestration C402.4.4 Envelope reflectance in U-factor of opaqueaque doors associated with the ❑ ❑ building thermal envelope meets requirements. SYSTEM —SPECIFIC C403.2.12.1 Mechanical HVAC fanl systems at design conditions do not exceed al�owable fan system motor nameplate hp or fan sys bhp. SYSTEM —SPECIFIC C403.2.12.2 Mechanical HVAC fan not oversized beyond allowable ❑ ❑ lmomotors limits. SYSTEM —SPECIFIC C403.2.3(8) Table Mechanical Heat Reje?tion Equipment: Minimum Efficiency Requirement meet those listed in Table HVAC C403.2.7 Mechanical C403.2.3(8) Exhaust aiIr energy recovery on systems meeting Table C403.2.7(1) and C403.2.7(2). SYSTEM —SPECIFIC C403.3 Mechanical Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high -limit shut-off, integrated economizer control, and provide a means to r lieve excess outside air during SYSTEM —SPECIFIC C403.3.2 Mechanical operation. I❑ Economizer operation will not increase heating ❑ energy useiduring normal operation. SYSTEM —SPECIFIC C403.3.4, Mechanical Water economizers provided where required, C403.3.4.1, meet the requirements for design capacity, C403.3.4.2, maximum pressure drop and integrated C403.3.1 SYSTEM —SPECIFIC C403.4.2.1 Mechanical economier,control. Three -pipe hydronic systems using a common ❑ ❑ return for hot and chilled water are not used. SYSTEM_ SPECIFIC C403.4.2.3.1 Mechanical Hydronic heat pump systems connected to a common water loop meet heat rejection and heat addition reqcuit'c SYSTEM SPECIFIC C403.4.3.4 Mechanical t. 'cooling Open -circuit (cooling towers having water cooled ❑ ❑ chiller systems and multiple or vairable speed condenser pumps, are designed so that tower cells can run lin parallel with larger of flow crtieria. SYSTEM —SPECIFIC C404.2 Mechanical Service water heating equipment meets efficiency ❑ ❑ requirementsi Wattage C405.3 Interior Lighting f Exit signs do hot exceed 5 watts per face. 2. To be checked by -Plan Reviewer Plan Review C103.2 Envelope Plans and/or specifications provide all information with which ccrIrpliance can be determined for the building envelope and document where exceptions to the standard are claimed. II EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant So fare. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 1. Page 10 of 26 Plan Review C103.2 Plan Review C103.2 Plan Review C103.2 Plan Review C103.2 e Insulation Insulation HVAC Insulation Air Leakage SYSTEM —SPECIFIC HVAC HVAC C402.2.5 C402.2.6 C402.2.6 C402.2.6 C402.5.7 C403.2.12.3 C403.2.13 C403.2.4.2 y SYSTEM —SPECIFIC C403.2.4.4 SYSTEM —SPECIFIC C403.2.4.7 SYSTEM —SPECIFIC C403.2.5 HVAC C403.2.6.1 SYSTEM —SPECIFIC C403.4.1.1 SYSTEM —SPECIFIC C403.4.1.3 SYSTEM —SPECIFIC C403.4.2 Mechanical Plans, 'specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per accapt Ible engineering st Mechanical Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized peer manufact Interior Lighting Plans, specifications, and/or calculations provide all infor i ation with which compliance can be determined for the interior lighting and electrical systems land equipment and document where exceptions to the standard are claimed. Information provided shoul Exterior Lighting Plans, specifications, and/or calculations provide all informlation with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided shoul Envelope Slab edge insulation depth/length. Slab insulation extendingl away from building is covered by pavement or >= 10 inches of soil. Project Radiant heating systems panels insulated to >=R-3.5 o face opposite space being heated. Mechanical Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. Envelope Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Envelope Vestibules are installed on all building entrances. Doors have self -closing devices. Mechanical Fans have 'efficiency grade (FEG) >= 67. The total efficiency of the fan at the design point of operation <I 15% of maximum total efficiency of the fan. Mechanical Unenclosed spaces that are heated use only radiant heat. Mechanical Each zone 'equipped with setback controls using automatic time clock or programmable control system. Mechanical Zone isolation devices and controls installed where applicable. Mechanical Fault detection and diagnostics installed with air-cooled unitary DX units having economizers. Mechanical Hot water boilers supplying heat via one- or two -pipe systems include outdoor setback control. ltrol Mechanical Demand con ventilation provided for spaces >500 ft2 and'>25 peoplel1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow>3,000 cfm. Mechanical Hydronic andlmultizone HVAC system controls areVAV fans driven by mechanical or electrical variable speed drive per Table C403.4.1.1. Mechanical Reset static pressure setpoint for DDC controlled VAV boxes rel orting to central controller based on the zones regsuiring the most pressure. Mechanical Temperature reset by representative building loads in pumping systems for chiller and boiler systems>500�000 Btu/h. 0 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Souare. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 I Page 11 of 26 7/23/2019 SYSTEM —SPECIFIC . C403.4.2.3.2.1 Mechanical Closed-circuit cooling tower within heat pump loop 0 ❑ EJ have ether automatic bypass valve or lower leakage positive closure dampers. Open -circuit tower within heat pump loop have automatic valve to bypass all heat pump water flow around the tower. Open- or cl SYSTEM —SPECIFIC C403.4.2.4 Mechanical Hydronic systems greater than 500,000 Btu/h designed for variable fluid flow. SYSTEM —SPECIFIC C403.4.2.5 Mechanical System turndown requirement met through multiple single -input boilers, one or more modulating boilers, or a combination of single -input and modulating boilers. Boiler input between 1.0 MBtu/h and 5 MBtu/h has 3:1 turndown ratio, boiler input between 5.0 SYSTEM —SPECIFIC C403.4.2.6 Mechanical Chilledmultiple dithave El 1:1 M chilltomatialy through the Gapabilto replants duce flow a chiller plant when a chiller is shut down. Boiler plants with multiple boilers have the capability to reduce flow automatically through the boiler pliant SYSTEM —SPECIFIC C403.4.3, Mechanical Fan systems with motors —7.5 hp associated El El EJ C403.4.3.2 with heatl rejection equipment to have capability to operate It 2/3 of full -speed and auto speed controls to control the leaving fluid temperature or condensing temp/pressure of heat rejection device. SYSTEM_ SPECIFIC C403.4.4.5 Mechanical Multiple zone HVAC systems have supply air temperature reset controls. SYSTEM —SPECIFIC C403.4.4.6 Mechanical Multiple z ne VAV systems with DDC of individual 7s ❑ 0 zone bo have static pressure setpoint reset controls. SYSTEM_ SPECIFIC C404.2.1 Mechanical Gas -fired water -heating equipment installed in new buildi� gs: where a singular piece of water -hewing equipment = 1,000 kBtu/h serves the entire building, thermal efficiency — 90 Et. Where m0iple pieces of water -heating equipment Iserve the building wi SYSTEM —SPECIFIC C404.4 Mechanical All piping insulated in accordance with section details and Table C403.2.10. SYSTEM —SPECIFIC C404.5, C404.5.1, Mechanical Heated wa er supply piping conforms to pipe C404.5.2 length and volume requirements. Refer to section details. SYSTEM —SPECIFIC C404.6.3 Mechanical Pumps that�circulate water between a heater and storage tan have controls that limit operation from startup to <= 5 minutes after end of heating cycle. SYSTEM —SPECIFIC C404.7 Mechanical Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this s},stem have controls that start the pump upon receiving Wattage C405.5.1 Exterior Lighting Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed wafts are less than or equal to allowed watts. Plan Review C405.6 Project Group R-2 dwelling units have separate electrical El ❑ El meters. Plan Review C406 Project Plans, specifilI tions, and/or calculations provide ❑ ❑ all information with which compliance can be determined for the additional energy efficiency package options. SYSTEM —SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have ❑ El M means to balance and have pressure test connections. J SYSTEM —SPECIFIC C408.2.2.2 Mechanical HVAC hydromc heating and cooling coils have means to balance and have pressure test connections. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option . Page 12 of 26 I I 3. To be checked�by.11nspector Insulation C303.1 Envelope Roof inIsulation installed per manufacturers€TMs instructions. Blown or poured loose -fill insulation is installed only where the roof slope is <=3 in 12. Insulation C303.1 Envelope Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Fenestration C303.1.3 Envelope Fenestration products rated in accordance with NFRC. Fenestration C303.1.3 Envelope Fenestration products are certified as to perform aIlabels or certificates provided. Insulation C303.2, C402.2.4 Envelope lnce Floor insulation installed per manufacturer's El 1:1 ❑ instructions. Cavity or structural slab insulation installed in permanent contact with underside of decking 6r structural slabs. Insulation C303.2.1 Envelope Exterior nsulation protected against damage, sunlight,�moisture, wind, landscaping and equipment maintenance activities. Insulation C303.2.1 Envelope Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Insulation C402.1.3 Envelope Non -swinging opaque doors have R-4.75 insulation Insulation C402.2.2 Envelope Skylight cLbs are insulated to the level of roofs with insulation above deck or R-5. Insulation C402.2.2 Envelope Insulation )intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Air Leakage C402.5 Envelope Building envelope contains a continuous air barrier that has been tested and deemed to limit air leakage — 0.40 cfm/ft2. Air Leakage C402.5.1 Envelope The building envelope contains a continuous air barrier tha� is sealed in an approved manner and either constructed or tested in an approved manner. Air barrier penetrations are sealed in an approved manner. Air Leakage C402.5.1.1 Envelope All sources lof air leakage in the building thermal envelope arle sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor -perm able wrapping material to minimize air leakage. Air Leakage C402.5.1.2.1 Envelope The building envelope contains a continuous air barrier that is sealed in an approved manner and material permeability <= 0.004 cfm/ft2. Air barrier penetrations are sealed in an approved manner. Air Leakage C402.5.1.2.2 Envelope The building) envelope contains a continuous airEl El ❑ barrier that i� sealed in an approved manner and average assembly air leakage <= 0.04 cfm/ft2. Air barrier penetrations are sealed in an approved Air Leakage C402.5.2, C402.5.4 Envelope manner. Factory-built(fenestration and doors are labeled as meeting air leakage requirements. Air Leakage C402.5.3 Envelope Where open combustion air ducts provide combustion air to open combustion fuel burning appliances, tiie appliances and combustion air opening are located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope Air Leakage C402.5.5, Envelope Stair and elevator shaft vents have motorizedEl El ❑ C403.2.4.3 dampers that )automatically close. Air Leakage C402.5.5, Envelope Outdoor air and exhaust systems have motorized C403.2.4.3 dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Air Leakage C402.5.6 Envelope Weatherseals installed on all loading dock cargo El 1:1 El doors. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 I Page 13 of 26 r t, Air Leakage C402.5.8 Envelope Recessed luminaires in thermal envelope to limit ❑ infiltration and be IC rated and labeled. Seal betwee', interior finish and luminaire housing. HVAC C403.2.1 Mechanical HVAC systems and equipment design loads calculated in accordance with ANSI/ASHRAE/ACCA Standard 183 or by an approved equivalent computational procedure SYSTEM —SPECIFIC C403.2.10 Mechanical HVAC piping insulation thickness. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. HVAC C403.2.3 Mechanical HVAC e6ipment efficiency verified. SYSTEM —SPECIFIC C403.2.3 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. labeled for replacement only as per Footnote b to Table C4103.2.3(3). SYSTEM —SPECIFIC C403.2.4.1 Mechanical Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. SYSTEM —SPECIFIC C403.2.4.1.1 Mechanical Heat purr1p controls prevent supplemental electric ❑ ❑ resistance heat from coming on when not needed. HVAC C403.2.4.1.2 Mechanical Thermostatic controls have a 5 A°F deadband. El 1:1 El HVAC C403.2.4.1.2 Mechanical Thermostatic controls have a 5 A°F deadband. HVAC C403.2.4.1.3 Mechanical Temperat lire controls have setpoint overlap restrictions. HVAC C403.2.4.2.1, Mechanical Automatic Controls: Setback to 55°F (heat) and C403.2.4.2.2 85°F (coolit; 7-day clock, 2-hour occupant override, 10-hour backup SYSTEM —SPECIFIC C403.2.4.2.3 Mechanical Systems include optimum start controls. El HVAC C403.2.4.5, Mechanical Snow/ice melting system sensors for future ❑ El C403.2.4.6 connection to controls. Freeze protection systems have automatic controls installed. HVAC C403.2.6.2 Mechanical Enclosed p�rking garage ventilation has automatic contaminant detection and capacity to stage or mgdulate fans to 50% or less of design capacity. HVAC C403.2.9 Mechanical HVAC ducts) and plenums insulated. Where ducts or plenums �re installed in or under a slab, verification rpay need to occur during Foundation Inspection. SYSTEM —SPECIFIC C403.2.9.1.3 Mechanical Ductwork operating >3 in. water column requires 1:1 El air leakage testing. SYSTEM SPECIFIC C403.4.1.2 Mechanical VAV fans have static pressure sensors located so controller setpoint —1.2 w.c.. SYSTEM —SPECIFIC C403.4.2.2 Mechanical Two -pipe hydronic systems using a common distribution s�stem have controls to allow a deadband >!15°F, allow operation in one mode for at least 4 hrs before changeover, and have rest controls to limit heating and cooling supply temperature 1I < 30 *F. SYSTEM —SPECIFIC C403.4.2.3.3 Mechanical Two -position automatic valve interlocked to shut off water flowlwhen hydronic heat pump with pumping system >10 hp is off. SYSTEM —SPECIFIC C403.4.4.5, Mechanical Zone controlslcan limit simultaneous heating and C403.4.4.5.1-4 cooling and sequence heating and cooling to each zone. SYSTEM —SPECIFIC C403.4.5 Mechanical Condenser heat recovery system that can heat water to 850F or provide 60% of peak heat rejection is installed for preheating of service hot water. I SYSTEM —SPECIFIC C403.4.6 Mechanical Hot gas bypass limited to: < 240 kBtu/h 150% capacity, >240 kBtu/h - 25% capacity SYSTEM —SPECIFIC C404.3 Mechanical Heat traps installed on non -circulating storage water tanks. I I EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 Page 14 of 26 I SYSTEM —SPECIFIC C404.3 Mechanical Heat traps installed on supply and discharge U u U piping of non -circulating systems. SYSTEM —SPECIFIC C404.3 Mechanical Heat traps installed on supply and discharge piping of non -circulating systems. SYSTEM —SPECIFIC C404.6.1 Mechanical Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank. System return pipe is a delicated return pipe or a cold water supply SYSTEM_ SPECIFIC C404.6.1, C404.6.2 pipe. Mechanical Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace. SYSTEM_ SPECIFIC C404.9.1 Mechanical Pool heaters are equipped with on/off switch and no continuously burning pilot light. SYSTEM —SPECIFIC C404.9.2 Mechanical Time swatches are installed on all pool heaters and pumps. SYSTEM_SPECIFIC C404.9.2 Mechanical Time swiltches are installed on all pool heaters ❑ EI and pumps. SYSTEM —SPECIFIC C404.9.3 Mechanical Vapor retlardant pool covers are provided for ❑ heated pools and permanently installed spas. Controls C405.2:1 Interior Lighting Lighting controls installed to uniformly reduce the lighting load by at least 50%. Controls C405.2.1 Interior Lighting Occupancy sensors installed in required spaces. Controls C405.2.1, Interior Lighting Independent lighting controls installed per C405.2.2.3 approved lighting plans and all manual controls readily accessible and visible to occupants. Controls C405.2.2.1 Interior Lighting Automaticicontrols to shut off all building lighting El installed irk all buildings. Controls C405.2.3 Interior Lighting Daylight zones provided with individual controls 1:1 El that contro the lights independent of general area lighting. Controls C405.2.3, Interior Lighting Primary silelighted areas are equipped with 1:1 El ❑ C405.2.3.1, required lighting controls. C405.2.3.2 Controls C405.2.3, Interior Lighting Enclosed spaces with daylight area under C405.2.3.1, skylights a d rooftop monitors are equipped with C405.2.3.3 required I J;ng controls. Controls C405.2.4 Interior Lighting Separate lighting control devices for specific uses El El D installed peg approved lighting plans. Wattage C405.2.4 Interior Lighting Additional interior lighting power allowed for special functions per the approved lighting plans and is auto atically controlled and separated from genera lighting. Controls C405.2.5 Exterior Lighting Automatic lighting controls for exterior lighting installed. Controls will be daylight controlled, set based on 4iness operation time -of -day, or reduce conn cted lighting > 30%. Wattage C405.4.1 Interior Lighting Interior insta ed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Mandatory Additional Eff C406.4 Project Enhanced digital lighting controls efficiency package: Interior lighting has following enhanced lighting controls in accordance with Section C405.2.2: Luminaires capable of continuous dimming and being addressed individually, <= 8 luminaires controlled in l Mandatory Additional Eff C406.6 Project Dedicate outdoor air system efficiency package: Buildings withlhydronic and/or multiple -zone HVAC systems are equipped with an independent ventilation system designed to provide >_ 100-percent outdoor air to each individual occupied space, as specified by 7/23/2019 I I I EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option Page 15 of 26 I I 7/23/2019 i Mandatory Additional Eff C406.7, C406.7.1 " Project Enhanced Service Water Heat System efficiency package''One of the following SWH system enhancements must satisfy 60 percent of hot water requirements, or 100 percent if the building otherwise complies with heat recovery per Section C403.4.b: Waste heat re HVAC C408.2.2.1 Mechanical Air outlets and zone terminal devices have means for air bal lancing. HVAC C408.2.2.1 Mechanical Air outlets and zone terminal devices have means for air balancing. Testing C408.2.3.2 Mechanical HVAC cointrol systems have been tested to ensure proper operation, calibration and adjustor Int of controls. 4. To be checked by Inspector at Project Completion and Prior to Issuance of Certificate of Occupancy Post Construction C303.3, C408.2.5.2 Interior Lighting Furnished O&M instructions for systems and _ equipment to the building owner or designated representative. Post Construction C303.3, C408.2.5.3 Mechanical Fumishec O&M manuals for HVAC systems within 90 days of system acceptance. Fenestration C402.4.2.2 Envelope Skylights in office, storage, automotive service, manufactdring, non -refrigerated warehouse, retail store, andldistribution/sorting area have a measured haze value > 90 percent unless designed to exclude direct sunlight. Post Construction C408.2.1 Mechanical Commissioning plan developed by registered design professional or approved agency. Post Construction C408.2.3.1 Mechanical HVAC equipment has been tested to ensure proper opelration. Post Construction C408.2.3.3 Mechanical Economize) s have been tested to ensure proper ❑ ❑ ❑ operation. Post Construction C408.2.4 Mechanical Preliminary commissioning report completed and certified by egistered design professional or i approved agency. Post Construction C408.2.5.1 Mechanical Furnished �VAC as -built drawings submitted within 90 days of system acceptance. Post Construction C408.2.5.1 Interior Lighting Furnished as -built drawings for electric power systems within 90 days of system acceptance. Post Construction C408.2.5.3 Mechanical An air and/o hydronic system balancing report is provided for HVAC systems. Post Construction C408.2.5.4 Mechanical Final commi sioning report due to building owner within 90 da I s of receipt of certificate of Post Construction C408.3 Interior Lighting occupancy. Lighting systems have been tested to ensure ❑ proper calibration, adjustment, programming, and operation. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant SofWIare. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Toial Building Performance Compliance Option Page 16 of 26 I Input Datal Report Proiect Information Project Name: Pursuit Project Titlel Pursuit Boat Factory Address: 3901 St Lucie Blvd State: FL Zip: 34946 • Owner: Building Type: Manufacturing Facility Budding Classification: New Finished building No.of Stories: 1 GroSsArea (SF): 18,230 Bldg. Rotation: None Zones No Acronym Description Type I Area lsfl Multi Total Area lsfl 1 Zone 1 Offices CONDITIONED 3263.0 1 3263.0 2 Zone 2 Warming Pantry CONDITIONED 352.0 1 352.0 3 Zone 3 Break Rm East CONDITIONED 3193.0 1 3193.0 4 Zone 4 Break Rm West CONDITIONED 1512.0 1 1512.0 5 Zone 5 Electrical Rooms CONDITIONED 780.0 1 780.0 6 Zone 6 Upholstery and Electrical CONDITIONED 9130.0 1 9130.0 r l EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 I Page 17 of 26 No Acronym Description Type Depth Width Height Mult Total Total Ift] IN IN Area Vol]cf] IsfJ In Zone: Zone 1 1 Zone 1 Offices Office -Enclosed 65.26 50.00 25.00 1 3263.0 81575.0 In Zone: Zone 2 - 1 Zone 1 Warming Pantry Office - Enclosed 17.60 20.00 25.00 1 352.0 8800.0 ❑ In Zone: Zone 3 - 1 Zone I Break Rm East Office - Enclosed 63.86 50.00 25.00 I 3193.0 79825.0 ❑ In Zone: Zone 4 1 Zone 1 Break Rm West Office - Enclosed 21.00 72.00 25.00 1 1512.0 37800.0 In Zone: Zone 5 1 Zone 5 Electrical Rooms Office - Enclosed 30.00 26.00 25.00 1 780.0 19500.0 In Zone: Zone 6 1 Zone 6 Upholstery and Workshop 91.30 100.00 25.00 1 9130.0 228250.0 Electrical EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 II Page 18 of 26 I Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: Zone 1 In Space: Zone 1 _ 1 LED Exit Sign 3 4 12 Security (continuous) I ❑ 2 LED General Lighting 25 43 1068 Manual On/Off 7 ❑ In Zone: Zone 2 In Space: Zone 1 1 LED Exit Sign 1 4 4 Security (continuous) 1 ❑ 2 LED General Lighting 4 40 161 Manual On/Off 1 ❑ In Zone: Zone 3 In Space: Zone 1 1 LED Exit Sign e 2 4 8 Security (continuous) 1 ❑ 2 LED General Lighting 5 40 202 Manual On/Off 3 ❑ 3 LED General Lighting 4 43 171 Manual On/Off 4 ❑ In Zone: Zone 4 In Space: Zone 1 1 LED Exit Sign 3 4 12 Security (continuous) 1 ❑ 2 LED General Lighting 25 43 1068 Manual On/Off 7 ❑ In Zone: Zone 5 In Space: Zone 5 1 LED Exit Sign 2 4 8 Security (continuous) 1 ❑ 2 LED General Lighting 4 43 171 Manual On/Off 2 ❑ In Zone: Zone 6 In Space: Zone 6 1 LED Exit Sign 3 3 9 Security (continuous) 1 ❑ 2 LED General Lighting 80 70 5600 Manual On/Off 8 ❑ I I EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Softwlare. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 I Page 19 of 26 I I Walls (Walls will be rotated clockwise by building rotation value) No Description Type Width H (Effec) Multi Area Orient Cond- Heat Dens. R-Value [ft] [ft] plier [sf] ation uctance Capacity [lb/cf] [h.sEFBtu] [Btu/h.sf.Fl [Btu/sf.F] In Zone: Zone 1 1 PrOZolWal 0.5 Ply/35/8" Mtl 32.00 25.00 1 800.0 West 0.0444 1.009 8.59 22.5 ❑ std@24"oc/R19/0.5" Gyp In Zone: Zone 4 I PrOZolWal 0.5 Ply/35/8" Mtl 32.00 25.00 1 800.0 West 0.0444 1.009 8.59 22.5 ❑ std@24"oe/R19/0.5" Gyp In Zone: Zone 5 1 PrOZolWal 0.5 Ply/35/8" Mtl 26.00 25.00 1 650.0 West 0.0444 1.009 8.59 22.5 ❑ std@24"oc/RI9/0.5" Gyp In Zone: Zone 6 1 PrOZolWal 0.5 Ply/35/8" Mtl 100.00 25.00 2500.0 West 0.0444 1.009 8.59 22.5 ❑ std@24"oc/RI9/0.5" Gyp II Windows (Windows will be rotated clockwise by building rotation value) No Description Orientation Shaded U SHGIC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F] I IN IN plier [sq In Zone: Zone 1 In Wall: West Wall 1 PrOZol%lWil West No 0.5000 0.25 0.76 2.70 2.70 2 14.6 ❑ In Zone: Zone 4 In Wall: West Wall 1 PrOZo l Wa1 Wll West No 0.5000 0.25 0.76 21.00 2.70 2 113.4 ❑ EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1,0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Tot lal Building Performance Compliance Option 7/23/2019 I Page 20 of 26 No Description Type In Zone: Zone 1 In Wall: West Wall - 1 PrOZolWa4Drl Solid core flush (2.25) In Zone: Zone 4 In Wall: West Wall 1 PrOZolWa4Drl Solid core flush (2.25) In Zone: Zone 5 In Wall: West Wall I Pr0ZolWa4Dr1 Solid core flush (2.25) i In Zone: Zone 6 In Wall: West Wall 1 PrOZolWa4Drl Solid core flush (2.25) 2 PrOZo6WalDr2 Solid core flush (2.25) Shade? Width H (Effec) Multi Area Cond. Dens. Ht Cap. R IN [ft] plier [sf] [Btu/h.sf.F] [Ib/cf] [Btu/sf. [h.sf.F/ No 3.00 8.00 1 24.0 0.3504 0.00 0.00 2.85 No 3.00 8.0 , 2 24.0 0.3504 0.00 0.00 2.85 No 3.00 8.00 1 24.0 0.3504 0.00 0.00 2.85 No 3.00 8.00 2 24.0 0.3504 0.00 0.00 2.85 No 12.00 12.00 2 144.0 0.3504 0.00 0.00 2.85 No Description Type Width IN H (Effec) [ft] Multi Area pl ier [sf] Tilt [deg] Cond. [Btu/h.SE F1 Heat Cap Dens. R-Value [Btu/sf. F] [lb/cf] [h.sf.FBtu In Zone: Zone 1 1 PrOZoIRf2 Mtl Bldg Roof/R-30 50.00 65.26 1 3263.0 0.00 0.0330 30.3 Batt In Zone: Zone 2 1 PrOZOIRf2 Mt1Bldg Roof/R-30 20.00 17.60 1 352.0 0.00 0.0330 30.3 Batt In Zone: Zone 3 1 PrOZoIRf2 MdBldgRoof/R-30 50.00 63.86 1 3193.0 0.00 0.0330 30.3 Batt In Zone: Zone 4 I PrOZOIRf2 Mtl Bldg Roof/R-30 72.00 21.00 1 �I 1512.0 0.00 0.0330 30.3 Batt In Zone: Zone 5 1 Pr0ZolRf2 Md Bldg Roof/R-30 26.00 30.00 2 780.0 0.00 0.0330 30.3 Batt In Zone: Zone 6 1 PrOZOIRf2 Mtl Bldg Roof/R-30 100.00 91.30 1 9130.0 0.00 0.0330 30.3 Batt I EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Toial Building Performance Compliance Option 7/23/2019 I Page 21 of 26 Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multi- Area Total Area [Btu/hr sf F] [ft] [ft] plier [Sfl [Sfl In Zone: In Roof: Floors No Description Type Width H (Effe) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/h.sf.F [Btu/sf. F] [lb/cf] [h.sf.F/Btu In Zone: Zone 1 I PrOZo1F12 1 ft. soil, concrete 50.00 65.26 1 3263.0 0.2681 34.00 113.33 3.73 floor, carpet and rubber pad In Zone: Zone 2 1 Pr0Zo1F12 I ft. soil, concrete 20.00 17.60 1 352.0 0.2681 34.00 113.33 3.73 floor, carpet and rubber pad In Zone: Zone 3 I PrOZo1F12 1 ft. soil, concrete 50.00 63.86 I 3193.0 0.2681 34.00 113.33 3.73 floor, carpet and rubber pad In Zone: Zone 4 1 PrOZolF12 1 ft. soil, concrete 72.00 21.00 1 1512.0 0.2681 34.00 113.33 3.73 floor, carpet and rubber pad In Zone: Zone 5 1 PrOZo1F12 1 ft. soil, concrete 26.00 30.00 1 780.0 0.2681 34.00 113.33 3.73 floor, carpet and rubber pad In Zone: Zone 6 1 Pr0Zo1F12 1 ft. soil, concrete 100.00 91.30 1 9130.0 0.2681 34.00 113.33 3.73 floor, carpet and rubber pad I I EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant SoftvNare. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Toial Building Performance Compliance Option 7/23/2019 Page 22 of 26 I Systems Zone 1 2 ea. 5 ton Split AC Constant Volume Air Cooled No. Of Units Split System < 65000 Btu/hr 2 I j Component Category Capacity Efficiency IPLV 1 Cooling System 60000.00 17.00 12.90 ❑ 1 2 Heating System 24566.00 1.00 ❑ I 3 Air Handling System -Supply 1800.00 0.80 ❑ Zone 2 1 ea. 2 ton Split AC Constant Volume Air Cooled No. Of Units Split System < 65000 Btu/hr 1 Category Opacity Efficiency IPLV IComponent 1 Cooling System 24000.00 17.00 12.90 ❑ 2 Heating System �800.826.00 1.00 El3 Air Handling System -Supply 00 0.80 ❑ Zone 3 1 ea. 10 Ton Split AC Condensing Units No. Of Units ' 1 Component Category Ca acity Efficiency IPLV j 1 Cooling System 1 0000.00 12.70 12.20 ❑ 2 Heating System 8 027.00 1.00 ❑ l3 Air Handling System -Supply 3I575.00 0.60 ❑ Zone 4 1 ea. 6 Ton Split AC Condensing Units No. Of Units ' 1 Component Category Capacity Efficiency IPLV 1 Cooling System 72000.00 12.00 11.80 ❑ 2 Heating System 51600.00 1.00 ❑ 3 Air Handling System -Supply 2�00.00 0.80 ❑ I� Zone 5 2 ea. 5 ton Split AC Constant Volume Air Cooled No. Of Units Split System < 65000 Btu/hr 2 Component Category Cap city Efficiency IPLV 1 Cooling System 600100.00 17.00 12.90 ❑ 2 Heating System 245I66.00 1.00 El 3 Air Handling System -Supply 1800.00 0.80 ❑ , Zone 6 2 ea. 10 Ton Split AC Condensing Units No. Of Units 2 Component Category Capacity Efficiency IPLV 1 Cooling System 120060.00 12.70 12.20 ❑ 2 Heating System 8502117.00 1.00 ❑ 3 Air Handling System -Supply 3575.00 0.60 ❑ j I II EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Softwl re. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 Page 23 of 26 II Plant Equipment Category Sizll Inst.NoEff. IPLV Water Heaters I W-Heater Description I Capacity Cap.Unit I/P Rt. Efficiency Loss 1 Gas Storage water heater 65 [Gal] 5 [Btu/h] 0.7900 [Ef/Et] [Btu/hi ❑ Ext-Lighting Description Category No. of Watts per LumitI- Lumin- aired aire Area/Len/No [sUft/No] Control Type Wattage [W] El Piping II No Type Operating Ins'Iulation Temp Conductivity [F] [ Btuiin/h.sf.F] Nomonal pipe Diameter [in] Insulation Thickness [in] Is Runout? I I I EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Softwlre. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 Page 24 of 26 I I Fenestratio I Used Glasll Name Glass Type No. of Conductance SHGC VLT Panes [Btu/h.st:F] ApLbWndl5 User Defined 1 0.500 0.2500 0.7600 Materials t lI sed Mat No Acronym Description Only I RValue Thick Cond- Density Sp. Heat R-Value [h.s£F/Btu] [ft] uctivity [lb/cf] [Btu/1b.F] Used I [Btu/h.ft.F 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 211 Mat1211 POLYSTYRENE,EXP.,1/2IN No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ 23 Mat][23 6 in. Insulation No 0.0000 0.5000 0.0250 5.70 0.2000 ❑ 279 Mat1279 Solid core flush (2.25") Yes 2.8537 ❑ 94 Mat194 BUILT-UP ROOFING, 3/81N No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 1003 ApLbMat1003 R-30 Generic Insulation Yes 30.0000 ❑ EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Softw6re, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - TotIpl Building Performance Compliance Option 7/23/2019 1 Page 25 of 26 Constructs (Used Simple Massless Conductance Heat Cap Density RValue No Name Construct Const eyet [Btu/h.sf.F] [Btu/sfF] [lb/cf] [h.sf.F/Btu] 1017 0.5 Ply/35/8" Mt] No NII 0.04 1.01 8.59 22.5 ❑ std@24"oc/R19/0.5" Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 211 POLYSTYRENE,EXR,1/2IN, 0.0417 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ Simple MasslesI Conductance Heat Cap Density RValue No Name Construct cons tru t [Btu/h.sf.F] [Btu/sfF] [lb/ct] [h.sf.F/Btu] 1056 Mtl Bldg Roof/R-30 Batt No Yes I 0.03 30.3 ❑ Layer Material Material Thickness Framing No. Vt] Factor 1 94 BUILT-UP ROOFING, 3MIN 0.0313 0.000 ❑ 2 1003 R-30 Generic Insulation 0.6548 0.000 ❑ Simple Massless Conductance Heat Cap Density RValue No Name Construct Construe [Btu/h.sf.F] [Btu/sfF] [lb/cf[ [h.sf.FBtu] 1057 1 ft. soil, concrete floor, carpet and No No I 0.27 34.00 113.33 3.7 ❑ rubber pad Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ Simple Massless I Conductance Heat Cap Density RValue No Name Construct Construct [Btu/h.sf.Fl [Btu/sf.F] [lb/cf[ [h.sf.FBtul 1058 Solid core flush (2.25) No Yes I 0.35 2.9 ❑ Layer Material i Material Thickness Framing No. li [ft] Factor 1 279 Solid core flush (2.25") I 0.000 ❑ I EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/23/2019 Page 26 of 26 I Right -Suite® Universal 2019 Load Summary Job: Pursuit Boat Factory E-Calcs B(ll�Cilll Date: Jul 23, 2019 g By: E-Calcs Plus, Inc. Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecaicsplus.com License: HERS Rater ID 0757810 For: Pursuit Boat Factory, Cardinal Engineering 3901 St Lucie Blvd, Fort Pierce, FL 34946 1. DESIGN CONDITIONS at Aug 1900 LDT Peak load at Aug 1900 LDT Inside: 75 °F Outside: 87 °F TD: 12 °F RH: 63 % MoistDiff: 59.4 grAb Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 4907 - 3. TRANSMISSION GAINS Sensible 88253 - Walls: 32797 - - Glass: 828 - - Doors: 8145 - - Partitions: 0 - - Floors: 0 - - Ceilings: 46483 - - 4. INTERNAL HEAT GAIN Sensible Latent 267488 22090 Occupants: 21185 22090 - - Lights: 122788 - - - Motors: 0 - - - Appliances: 123514 0 - - 5. INFILTRATION: Outside air cfm: 1175 15843 47399 6. SUBTOTAL: Space load Sensible Latent 376491 69489 Envelope 376491 69489 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLY DUCT 55750 S. SUBTOTAL: Space load + supply duct 432241 - Actual cfm: 21800 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 1094 14742 44105 10. RETURN AIR LOAD: Lighting + plenum (net) 0 - 11. RETURN DUCT 37816 12. TOTAL LOADS ON EQUIPMENT 489702 139387 13. DESIGN CONDITIONS °F °F Mult: 1.0 °F Inside: 70 Outside: 43 TAD: 27 14. TRANSMISSION LOSSES 90565 Walls: 42597 - Glass: 1823 - Doors: 8602 - Partitions: 0 - Floors: 7519 - Ceilings: 30025 15. INFILTRATION: Outside air cfm: 12915 86472 16. SUBTOTAL: Space load I 177037 Envelope 177037 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT: 47655 18. VENTILATION: Make-up air cfm: 1094 32451 19. HUMIDIFICATION I 48503 Piping 0 20. RETURN DUCT 11436 21. TOTAL HEATING LOAD ON EQUIPMENT 317081 Wrightsoft- 2019-Jul-23 08:13:08 -^ • - .M- Right -Suite® Universal 2019 19.0.09 RSU25198 Page 1 tory\Pursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E Right -Suite® Universal 2019 Load Summary Job: Pursuit Boat Factory E-Caics AHU 1 and 2 Date: Jul 23, sops By: E-Calcs Plus, Inc. Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecaicsplus.com License: HERS Rater ID 0757810 For: Pursuit Boat Factory, Cardinal E 3901 St Lucie Blvd, Fort Pierce, 1. DESIGN CONDITIONS at Aug 1900 LDT Peak load at Aug 1900 LDT Inside: 75 T Outside: 87 °F TD: 12 °F RK 63 % MoistDiff: 59.4 gr/lb Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 785 - 3. TRANSMISSION GAINS Sensible 15298 - Walls: 6523 - - Glass: 132 - - Doors: 322 - - Partitions: 0 - - Floors: 0 - - Ceilings: 8320 - - 4. INTERNAL HEAT GAIN Sensible Latent 36614 6798 Occupants: 3875 6798 - - Lights: 32739 - - - Motors: 0 - - - Appliances: 0 0 - - 5. INFILTRATION: Outside air cfm: 78 1056 3160 6. SUBTOTAL: Space load Sensible Latent 53753 9957 Envelope 53753 9957 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLY DUCT 8983 - 8. SUBTOTAL: Space load + supply duct 62736 - Actual cfm: 3625 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 196 2639 7894 10. RETURN AIR LOAD: Lighting + plenum (net) 0 - 11. RETURN DUCT 5945 - 12. TOTAL LOADS ON EQUIPMENT 72032 21781 HEATING LOAD 13. DESIGN CONDITIONS It 1.0 Inside: 70 T Outside: 43 °F T 27 °F 14. TRANSMISSION LOSSES 17178 Walls: 10153 - Glass: 292 - Doors: 340 - Partitions: 0 - Floors: 1020 - Ceilings: 5374 - 15. INFILTRATION: Outside air cfm: 10372 16. SUBTOTAL: Space load 1350 27551 Envelope 27551 - Less external 0 i - Less transfer 0 - Redistribution 0 17. SUPPLY DUCT: 7590 18. VENTILATION: Make-up air cfm: 196 5808 19. HUMIDIFICATION 6599 Piping 0 20. RETURN DUCT I 1821 21. TOTAL HEATING LOAD ON EQUIPMENT I 49369 wrigNtsott- I 2019-Jul-23 08:13:08 -- —.�--+ Right -Suite@ Universal 2019 19.0.09 RSU25198 Paget tory\Pursuit Boat Factory Reduced 7.23.2019.rup Cale = MN5 Front Door faces: E i Right -Suite® Universal 2019 Load Summary E-Calcs AHU.4 Plus,, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: edc@ecalcsplus.com For: Pursuit Boat Factory, Cardinal E 3901 St Lucie Blvd, Fort Pierce, 1. DESIGN CONDITIONS at Aug 1900 LDT Inside: 75 OF Outside: 87 OF RH: 63 % MoistDiff. 59.4 gr/lb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls: 0 Glass: 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 898 4. INTERNAL HEAT GAIN Sensible Occupants: 418 Lights: 3532 Motors: 0 Appliances: 10918 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Space load Sensible Envelope 15766 Less external 0 Redistribution 0 7. SUPPLY DUCT 8. SUBTOTAL: Space load + supply duct Actual cfm: 600 at supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURN AIR LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT 13. DESIGN CONDITIONS Inside: 70 OF Outside: 43 OF 14. TRANSMISSION LOSSES Walls: 0 Glass: 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 580 15. INFILTRATION: Outside air cfm: 16. SUBTOTAL: Space load Envelope 580 'Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT: 18. VENTILATION: Make-up air cfm: 19. HUMIDIFICATION Piping 20. RETURN DUCT 21. TOTAL HEATING LOAD ON EQUIPMENT w-rightsof - *.�.ny-s—. Right-Suite®Universal 2019 19.0.09 RSU25198 tory�Pursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E Job: Pursuit Boat Factory Date: Jul 23, 2019 By: E-Calcs Plus, Inc. License: HERS Rater ID 0757810 Peak load at Aug 1900 LDT TD: 12 OF Mult: 1.0 Ins.wb Sensible 0 898 Latent 733 0 0 Latent 733 ��, 20 21 0 21 14868 0 15766 2346 18112 285 0 1057 19659 1:0 27 OF 580 0 580 1826 627 256 0 287 3575 63 OF Latent 733 0 733 852 2661 2019-Jul-23 08:13:08 Page 3 Right -Suite® Universal 2019 9(z� E-Calcs AHU 5 Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcspl For: Pursuit Boat Factory, Cardinal E 3901 St Lucie Blvd, Fort Pierce, 1. DESIGN CONDITIONS at Aug 1900 LDT Inside: 75 °F Outside: 87 °F RK 63 % MoistDiff: 59.4 gr/lb 2. SOLAR RADIATION THROUGH GLASS S umm7 try Job: Pursuit Boat Factory Date: Jul 23, 2019 By: E-Calcs Plus, Inc. geenng 34946 3. TRANSMISSION GAINS Sensible Walls: 1479 Glass: 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 8142 4. INTERNAL HEAT GAIN Sensible Occupants: 3792 Lights: 32037 Motors: 0 Appliances: 27296 5: INFILTRATION: Outside air cfm: 6. SUBTOTAL: Space load Sensible Envelope 72745 Less external 0 Redistribution 0 7. SUPPLY DUCT 8. SUBTOTAL: Space load + supply duct Actual cfm: 3575 at supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURN AIR LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT 13. DESIGN CONDITIONS Inside: 70 °F Outside: 43 °F 14. TRANSMISSION LOSSES Walls: 3256 Glass: 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 5259 15. INFILTRATION: Outside air cfm: 16. SUBTOTAL: Space load Envelope 8514 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT: 18. VENTILATION: Make-up air cfm: 19. HUMIDIFICATION Piping 20. RETURN DUCT 21. TOTAL HEATING LOAD ON EQUIPMENT License: HERS Rater ID 0757810 Peak load at Aug 1900 LDT TD: 12 °F Mult: 1.0 Ins.wb 63 °F Sensible Latent 0 - 9620 - Latent 63125 6652 6652 - - 0 - - 0 0 0 Latent 72745 6652 6652 - - 0 - - 9007 - 81752 - 20 - - 192 2582 7725 0 - 6790 - 92052 18686 ult: 0 192 1.0 27 °F 8514 0, 8514 7139 5684 2318 0 1918 25573 wriyhott' 2019-Jul-23 08 :13:08 Right -Suite® Universal 2019 19.0.09 RSU25198 II Page tory\Pursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E Right -Suite® Universal 2019 E-Calcs AHU 6 Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcspli For: Pursuit Boat Factory, Cardinal E 3901 St Lucie Blvd, Fort Pierce, S urnmary Job: Pursuit Boat Factory Date: Jul 23, 2019 By: E-Calcs Plus, Inc. License: HERS Rater ID 0757810 1. DESIGN CONDITIONS at Aug 1900 LDT Peak load at Aug 1900 LDT Inside: 75 °F Outside: 87 °F TD: 12 °F RH: 63 % MoistDiff: 59.4 gr/Ib Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 4122 - 3. TRANSMISSION GAINS Sensible 11422 - Walls: 6226 - - Glass: 695 - - Doors: 644 - - Partitions: 0 - - Floors: 0 - - Ceilings: 3855 - - 4. INTERNAL HEAT GAIN Sensible Latent 10503 1008 Occupants: 1795 1008 - - Lights: 1884 - - - Motors: 0 - - - Appliances: 6824 0 - - 5. INFILTRATION: Outside air cfm: 510 6871 20557 6. SUBTOTAL: Space load Sensible Latent 32919 21565 Envelope 32919 21565 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLY DUCT 5454 - 8. SUBTOTAL: Space load + supply duct 38373 - Actual cfm: 2400 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 91 1223 3658 10. RETURN AIR LOAD: Lighting + plenum (net) 0 - 11. RETURN DUCT 2846 - 12. TOTAL LOADS ON EQUIPMENT 42877 27711 'HEATING LOAD 13. DESIGN CONDITIONS ult: 1.0 Inside: 70 °F Outside: 43 °F T 27 °F 14. TRANSMISSION LOSSES 11569 Walls: 4574 - Glass: 1531 - Doors: 680 - Partitions: 0 - Floors: 2294 - Ceilings: 2490 - 15. INFILTRATION: Outside air cfm: 973 28876 16. SUBTOTAL: Space load 40445 Envelope 40445 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT: 5341 18. VENTILATION: Make-up air cfm: 91 2691 19. HUMIDIFICATION 12875 Piping 0 20. RETURN DUCT 898 21. TOTAL HEATING LOAD ON EQUIPMENT 62249 -1+1- wrighlsof - I 2019-Jul-23 08:13:08 •-•- • •* �r�-. Right -Suite® Universal 2019 19.0.09 RSU25198 Page toryNPursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E Right -Suite® Universal 2019 E-Calcs AHU 7 '1,► Plus., Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric Surnmary Job: Pursuit Boat Factory Date: Jul 23, 2019 By: E-Calcs Plus, Inc. b: www.ecaicsplus.com License: HERS Rater ID 0757810 For: Pursuit Boat Factory, Cardinal Engineering 3901 St Lucie Blvd, Fort Pierce, FL, 34946 1. DESIGN CONDITIONS at Aug 1900 LDT Peak load at Aug 1800 LDT Inside: 75 °F Outside: 87 °F TD: 12 °F RH: 63 % MoistDiff: 59.4 gr/lb Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 0 - 3. TRANSMISSION GAINS Sensible 4505 - Walls: 3188 - - Glass: 0 - - Doors: 322 - - Partitions: 0 - - Floors: 0 - - Ceilings: 994 - - 4. INTERNAL HEAT GAIN Sensible Latent 38033 0 Occupants: 0 0 - - Lights: 3913 - - - Motors: 0 - - - Appliances: 34120 0 - - 5. INFILTRATION: Outside air cfm: 92 1241 3712 6. SUBTOTAL: Space load Sensible Latent 43778 3712 Envelope 43778 3712 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLY DUCT 2441 S. SUBTOTAL: Space load + supply duct 46219 - Actual cfm: 1800 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 23 315 944 10. RETURN AIR LOAD: Lighting + plenum (net) 0 - 11. RETURN DUCT 1776 - 12. TOTAL LOADS ON EQUIPMENT 48835 5773 13. DESIGN CONDITIONS fault: 1.0 Inside: 70 °F Outside: 43 °F TD: 27 °F 14. TRANSMISSION LOSSES 6726 Walls: 5329 - Glass: 0 - Doors: 340 - Partitions: 0 - Floors: 414 - Ceilings: 642 - 15. INFILTRATION: Outside air cfm: I 176 5214 16. SUBTOTAL: Space load 11940 Envelope 11940 - Less external 0 - Less transfer 0 I - Redistribution 0 17. SUPPLY DUCT: i 2104 18. VENTILATION: Make-up air cfm: 23 694 19. HUMIDIFICATION 2410 Piping 0 20. RETURN DUCT 548 21. TOTAL HEATING LOAD ON EQUIPMENT 17696 -Pi1- wrightsoft- I 2019-Jul-23 08:13:08 «,• - «,» , Right -Suite® Universal 2019 19.0.09 RSU25198 Page tory\Pursuit Boat FactoryReduced 7.23.2019.rup Calc = MN5 Front Door faces: E Right -Suite® Universal 2019 E-Calcs AHU 8 Cf�zn_Plus., Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: e6c@ecalcspli For: Pursuit Boat Factory, Cardinal E 3901 St Lucie Blvd, Fort Pierce, 1. DESIGN CONDITIONS at Aug 1900 LDT Inside: 75 °F Outside: 87 T RK 63 % MoistDiff. 59.4 gr/lb 2. SOLAR RADIATION THROUGH GLASS Summary Job: Pursuit Boat Factory Date: Jul 23, 2019' By: E-Calcs Plus, Inc. www.ecalcsplus.com License: HERS Rater ID 0757810 neering 34946 3. TRANSMISSION GAINS Sensible Walls: 1881 Glass: 0 Doors: 1795 Partitions: 0 Floors: 0 Ceilings: 994 4. INTERNAL HEAT GAIN Sensible Occupants: 463 Lights: 3913 Motors: 0 Appliances: 34120 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Space load Sensible Envelope 44407 Less external 0 Redistribution 0 7. SUPPLY DUCT S. SUBTOTAL: Space load + supply duct Actual cfm: 1800 at supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURN AIR LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT Peak load at Aug 1800 LDT TD: 12 °F Mult: 1.0 Ins.wb Sensible 0 4670 Latent 812 0 92 Latent 4524 I 20 23 38496 1241 44407 2445 46852 315 0 1801 49500 13. DESIGN CONDITIONS MUlt: 1.0 Inside: 70 T Outside: 43 °F TD: 27 °F 14. TRANSMISSION LOSSES 5404 Walls: 2452 - Glass: 0 - Doors: 1895 - Partitions: 0 - Floors: 414 - Ceilings: 642 - 15. INFILTRATION: Outside air cfm: 176 5214 16. SUBTOTAL: Space load 10618 Envelope 10618 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT: 2098 18. VENTILATION: Make-up air cfm: I 23 694 19. HUMIDIFICATION 2410 Piping j 0 20. RETURN DUCT I 552 21. TOTAL HEATING LOAD ON EQUIPMENT f 16372 63 T Latent 812 3712 4524 944 6594 Wf i9ht2so t- I 2019-Jul-23 08:13:08 - �- � Right -Suite® Universal 2019 19.0.09 RSU25198 Page 7 ...tory\Pursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E I Right -Suite® Universal 2019 E-Calcs AHU 9 and 10 Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: edc@ecalcspli Summary Job: Pursuit Boat Factory Date: Jul 23, 2019 By: E-Calcs Plus, Inc. www.eca[csplus.com License: HERS Rater ID 0757810 For: Pursuit Boat Factory, Cardinal Engineering 3901 St Lucie Blvd, Fort Pierce, FL1 34946 1. DESIGN CONDITIONS at Aug 1900 LDT Inside: 75 °F Outside: 87 T RH: 63 % MoistDiff. 59.4 gr/lb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls: 13500 Glass: 0 Doors: 5062 Partitions: 0 Floors: 0 Ceilings: 23280 4. INTERNAL HEAT GAIN Sensible Occupants: 10842 Lights: 44770 Motors: 0 Appliances: 10236 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Space load Sensible Envelope 113123 Less external 0 Redistribution 0 7. SUPPLY DUCT 8. SUBTOTAL: Space load + supply duct Actual cfm: 8000 at supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURN AIR LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT 13. DESIGN CONDITIONS Inside: 70 °F Outside: 43 T 14. TRANSMISSION LOSSES Walls: 16833 Glass: 0 Doors: 5346 Partitions: 0 Floors: 3377 Ceilings: 15037 15. INFILTRATION: Outside air cfm: 16. SUBTOTAL: Space load Envelope 77390 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT: 18. VENTILATION: Make-up air cfm: 19. HUMIDIFICATION Piping 20. RETURN DUCT 21. TOTAL HEATING LOAD ON EQUIPMENT Peak load at Aug 1900 LDT TD: 12 T Mult: 1.0 Ins.wb Sensible 0 41841 Latent 65848 6087 - 0 403 Latent 22345 0 20 548 1240 5434 113123 25074 138197 7383 0 17601 164748 1.0 27 T 40593 36797 77390 21558 16252 21636 0 5411 142247 63 °F Latent 6087 16258 22345 22089 56182 WrigiltSOft- 2019-Jul-23 08:13:08 P-•-• ��. Rig ht-Suite@Universal201919.0.09RSU25198 Page torylPursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E Right -Suite® -Universal 2019 Short Form Date: Jul23,20°atFact°ry -�aICS Date: J23, 2019 PIUSy Inc. s Building By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd. Suite B. Estero. FL 33928 Phone: 239.810.6106 Email: ericn° ecalcsDlus.com Web: www.ecalcsDIus.com License: HERS Rater ID 0757810 For: Pursuit Boat Factory, Cardinal Eng neerinl 3901 St Lucie Blvd, Fort Pierce, FL134946 Htg Clg I Htg Clg - Outside db (OF) 43 87 Inside db (OF) 70 75 Outside RH (%) 63 Inside RH (%) 50 Outside wb (°F) - 77 In wb (OF) - 63 Daily range (OF) - 15 Design TD (OF) 27 12 I. Moisture dill. (gr/Ib) - 59 Heating Equipment Cooling Equipment Make n/a Make ' Model n/a Model I Type n/a Type Efficiency n/a CqP / EER / SEER Heating Input 0 MBtuh Sehsible Cooling Heating Output 0 MBtuh La ent Cooling Humidifier 0 gpd To al Cooling Leaving Air Temp 0 OF Leaving Air Temp Actual Heating Fan 0 cfm Act al Cooling Fan Equipment Location Building System Type n/a Fan Motor Heat Type n/a Fan &-Motor Combined Efficiency 0 % Static Pressure Across Fan 0 in H2O n/a n/a n/a 0 0 MBtuh 0 MBtuh 0 MBtuh 0 OF 0 cfm NAME Area ft2 I Heat Loss Sensible I Gain Latent Gain Htg cfm I Clg cfm I Time AHU 1 and 2 3263 49369 72032 21781 0 3625 Aug 1900 LDT AHU 4 352 3575 19659 2661 0 600 Aug 1900 LDT AHU 5 3193 25573 92052 18686 0 3575 Aug 1900 LDT AHU 6 1512 62249 42877 27711 0 2400 Aug 1900 LDT AHU 7 390 17696 48835 5773 1800 1800 Aug 1900 LDT AHU 8 390 16372 49500 6594 1800 1800 Aug 1900 LDT AHU 9 and 10 9130 142247 164748 56182 0 8000 Aug 1900 LDT Building 18230 317081 1 489702 1 139387 1 36001 218001 Aug 1900 LDT , Job: PursultB°atPact°ty Right -Suite® Universal 2019 Short Form ICS Date: Jul 23, 2019 �-Ca Plus, lc. AHU land 2 By: E-talcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: edc@ecalcsplus.com Vyeb: www.ecaicsplus.com License: HERS Rater ID 0757810 For: Pursuit Boat Factory, Cardinal Eng`neenng 3901 St Lucie Blvd, Fort Pierce, FLI 34946 Htg Clg Outside db (°F) 43 87 Outside RH (%) - 63 Outside wb (°F) - 77 Daily range (°F) - 15 Moisture diff. (gr/lb) - 59 Heating Equipment Make Trane Model AFUE 100 Type Elec strip Efficiency 100 EFF Heating Input 14Z kW Heating Output 49.4 MBtuh Humidifier 17.5 gpd Leaving Air Temp 70.0 °F Actual Heating Fan 0 cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Htg Clg Inside db (°F) 70 '75 Inside RH (%) - 50 Inside wb -63 D6sign TD (°F) 27 112 Cooling Equipment Mike Trane (2 ea. 5 ton Split AC) Model 4TTA7060 Type Split AC COP / EER / SEER 12.8 Sensible Cooling 71.3 MBtuh Latent Cooling 30.6 MBtuh Total Cooling 101.9 MBtuh Leaving Air Temp 55.0 °F Actual Cooling Fan 3625 cfm AHU 1 and 2 PROPCV BLOWTHRU 80.0 % 0.5 in H2O NAME Area I Heat Sensible I I Latent I Htg Clg I Time ftz Loss Gain Gain cfm cfm Offices I 3263 I 49369 I 72032 I I 21781 I O I 36251 Aug 1900 LDT AHU 1 and 2 3263 49369 72032 I[ 21781 0 36251 Aug 1900 LDT wrightsoft" I 2019-Jul-23 08:13:08 ...�.r, _ Right -Suite@ Universal 2019 19.0.09 RSU25198 Page 2 torylPursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E I Right -Suite® Universal 2019 Short Form Job: Ju 23,20oatFactory E—CaICS Date: Jul 23, 2019 PE- Ink."'s AHU 4 By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: edc@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 Project• • For: Pursuit Boat Factory, Cardinal Engineering I 3901 St Lucie Blvd, Fort Pierce, FL 34946 Htg Clg Outside db (°F) 43 87 Outside RH N - 63 Outside wb (°F) - 77 Daily range (°F) - 15 Moisture diff. (gr/lb) - 59 Heating Equipment Make Trane Model Type Elec strip Efficiency 100 EFF Heating Input 2.9 kW Heating Output 9.9 MBtuh Humidifier 0.7 gpd Leaving Air Temp 70.0 °F Actual Heating Fan 0 cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Htg Clg Inside db CF) 70 75 Inside RH N - 50 l9side wb (°F) - 63 Design TD (°F) 27 12 Cooling Equipment Make Trane Model 4TTR7024A1 Tye Split AC COP / EER / SEER 17.0 Sensible Cooling 17.8 MBtuh Latent Cooling 7.6 MBtuh Toial Cooling 25.4 MBtuh Leaving Air Temp 55.0 °F Actual Cooling Fan 600 cfm AHU 4 PROPCV BLOWTHRU 80.0 % 0.5 in H2O NAME I Area Heat I Sensible I I Latent I Htg Clg Time ft2 Loss Gain Gain cfm cfm Pantry I 352 I 3575 I 19659 I I 2661 I 01 6001 Aug 1900 LDT AHU 4 352 3575 i 19659 I� 2661 1 01 6001 Aug 1900 LDT Wri htsofta ,. a. 9 ...�.-. Right -Suite® Universal 2019 19.0.09 RSU25198 tory'Pursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E 2019-Jul-23 08:13:08 Page 3 Right -Suite® Universal 2019 Short Form Job: Ju 23,'20oatFactory CS Date: Jul 2019 plus; Ins AHU 5 I By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: edc@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Pursuit Boat Factory, Cardinal Engineerinc 3901 St Lucie Blvd, Fort Pierce, FLl 34946 Htg Clg Outside db (IF) 43 87 Outside RH N - 63 Outside wb (IF) - 77 Daily range (IF) - 15 Moisture diff. (gr/lb) - 59 Heating Equipment Make Trane Model AFUE 100 Type Elec strip Efficiency 100 EFF Heating Input 10.0 kW Heating Output 34.1 MBtuh Humidifier 6.1 gpd Leaving Air Temp 70.0 IF Actual Heating Fan 0 cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Htg Clg Inside db (IF) 70 75 Inside RH N - 50 Inside wb (IF) - 63 D sign TD (IF) 27 12 Cooling Equipment Make Trane Model TTA12044 Type Split AC CQP / EER / SEER 12.2 Se sible Cooling 90.0 MBtuh La ent Cooling 30.0 MBtuh Toial Cooling 120.0 MBtuh Leaving Air Temp 55.0 IF Actual Cooling Fan 3575 cfm AHU 5 PROPCV BLOWTHRU 80.0 % 0.5 in H2O NAME Area ftz Heat Loss I Sensible I Gain I Latent Gain I Htg cfm Clg cfm I Time Break Rm E 1386 8184 58167 8111 0 2279 Aug 1900 LDT Cor 1 333 3107 6218 1949 0 236 Aug 1900 LDT Men BA 814 7595 15200 4764 0 578 Aug 1900 LDT Storage 1 132 779 2342 772 0 89 Aug 1900 LDT Women BA 528 5906 10125 3090 0 387 Aug 1900 LDT AHU 5 3193 25573 92052 18686 0 3575 Aug 1900 LDT -�- nrightsof[- ..-,. q ., Right -Suite@ Universal 2019 19.0.09 RSU25198 tory\Pursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E 2019-Jul-23 08:13:08 Page 4 r Ri ht-Suite® Universal.2O19 Short Form Job: Pursuit Boat Factory CaICS � Date: Jul 23, 2019 lu �— PE— cs AHU 6 By: E-Calcs Plus, Inc. c. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: edc@ecalcsplus.com Web: www.eralcsplus.com License: HERS Rater ID 0757810 For: Pursuit Boat Factory, Cardinal Engineerinc 3901 St Lucie Blvd, Fort Pierce, FL 34946 Htg Clg Outside db (°F) 43 87 Outside RH N - 63 Outside wb (°F) - 77 Daily range (°F) - 15 Moisture diff. (grAb) - 59 Heating Equipment Make Trane Model AFUE 100 Type Elec strip Efficiency 100 EFF Heating Input 15.0 kW Heating Output 51.2 MBtuh Humidifier 34.0 gpd Leaving Air Temp 70.0 °F Actual Heating Fan 0 Cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Htg Clg Inside db (°F) 70 75 Inside RH (%) - 50 Inside wb (°F) - 63 Design TD (°F) 27 12 Cooling Equipment '/EER/SEER -ible Cooling nt Cooling I Cooling ,ing Air Temp al Cooling Fan AHU 6 PROPCV BLOWTHRU 80.0 % 0.5 in H2O Trane TTA073F4 Split AC 15.0 42.9 MBtuh 18.4 MBtuh 61.3 MBtuh 55.0 °F 2400 cfm NAME Area I Heat Sensible I I Latent I Htg I Clg Time ftz Loss Gain Gain Cfm cfm Break Rm W I 1512 I 62249 I 42877 I I 27711 I 01 24001 Aug 1900 LDT AHU 6 1512 62249 42877 I 1 27711 1 01 24001 Aug 1900 LDT I WrightsoW 2019-Jul-2308:13:08 . ..,., ....-.�,r� . Rig ht-Suite® Universal 2019 19.0.09 RSU25198 Page s tory\Pursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E T � Ri ht-Suite® Universal 2OIi19 Short Form Job: Pursuit Boat Factory E-Calcs Date: Jul 23, 2019 Plus, Inc. AHU 7 By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecaicsplus.com License: HERS Rater ID 0757810 For: Pursuit Boat Factory, Cardinal Engineerinc 3901 St Lucie Blvd, Fort Pierce, FL134946 Htg Clg Outside db (°F) 43 87 Outside RH N - 63 Outside wb (°F) - 77 Daily range (°F) - 15 Moisture diff. (gr/lb) - 59 Heating Equipment Make Model Type Efficiency Heating Input Heating Output Humidifier Leaving Air Temp Actual Heating Fan n/a n/a n/a n/a 0 MBtuh 0 MBtuh 6.4 gpd 70.0 °F 1800 cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Htg Clg Inlside db (°F) 70 75 Inside RH N - 50 Inside wb (°F) - 63 Design TD (°F) 27 12 Cooling Equipment Make Trane Model 4TTA7060A3 Type Split AC COP / EER / SEER 17.0 Sensible Cooling 45.6 MBtuh Latent Cooling 11.4 MBtuh Total Cooling 57.0 MBtuh Leaving Air Temp 55.0 °F Actual Cooling Fan 1800 cfm AHU 7 PROPCV BLOWTHRU 80.0 I % 0.5 in H2O NAME I Area I Heat I Sensible I Latent Htg I Clg I Time ftz Loss Gain Gain cfm cfm Elec Rm A I 390 I 17696 I 48835 Ij 5773 I 18001 18001 Aug 1900 LDT AHU 7 390 17696 48835 I� 5773 1 18001 18001 Aug 1900 LDT -�- wriigMtsof[- .�.-. q Right -Suite® Universal 2019 19.0.09 RSU25198 tory'Pursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E I ' i 2019-Jul-23 08:13:08 Page 6 Right -Suite® Universal 2O19.Short Form Job: Pursuit Boat Factory E-Calcs Date: Jul 23, 2019 Plus, Inc. AHU 8 By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: edc@ecalcsplus.com Web: www.ecaicsplus.com License: HERS Rater ID 0757810 For: Pursuit Boat Factory, Cardinal Engineering 3901 St Lucie Blvd, Fort Pierce, FL 34946 Htg Clg I Htg Clg Outside db ff) 43 87 Inside db (°F) 70 75 Outside RH (%) - 63 Inside RH (%) - 50 Outside wb (°F) - 77 Inside wb (°F) - 63 Daily range (°F) - 15 Design TD (°F) 27 12 Moisture dill. (gr/lb) - 59 Heating Equipment Cooling Equipment Make n/a ake Trane Model n/a Model 4TTA7060A3 Type n/a Type Split AC Efficiency n/a COP / EER / SEER 17.0 Heating Input 0 MBtuh Sensible Cooling 42.8 MBtuh Heating Output 0 MBtuh Latent Cooling 14.3 MBtuh Humidifier 6.4 gpd Total Cooling 57.0 MBtuh Leaving Air Temp 70.0 °F Leaving Air Temp 55.0 °F Actual Heating Fan 1800 cfm Actual Cooling Fan 1800 cfm Equipment Location AHU 8 System Type PROPCV Fan Motor Heat Type BLOWTHRLI Fan & Motor Combined Efficiency 80.0 % Static Pressure Across Fan 0.5 in H2O NAME Area Heat I Sensible I Latent I Htg Clg Time ft2 Loss Gain Gain cfm cfm Elec Rm B I 390 I 16372 I 49500 I I 6594 I 18001 18001 Aug 1900 LDT AHU 8 390 16372 49500 I 6594 1 1800 i 18001 Aug 1900 LDT V1/I'i9I7t5OfC' 2019-Jul-23 08:13:08 ,.. , ...�,« Right -Suite® Universal 2019 19.0.09 RSU25198 � i Page 7 tory\Pursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E 1 A Ri ght-Suite® Universal 2019 Short Form Job: Date: Ju 23,20oatFactory r—001C5 Jul 2019 plus; Inc. Plus., 9 and 10 By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: edc@ecalcsplus.com YNeb: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Pursuit Boat Factory, Cardinal Engineerinc 3901 St Lucie Blvd, Fort Pierce, FL 34946 Htg Clg Outside db (°F) 43 87 Outside RH (%) - 63 Outside wb (°F) - 77 Daily range (°F) - 15 Moisture diff. (gr/Ib) - 59 Heating Equipment Make Trane Model Type Elec strip Efficiency 100 EFF Heating Input 50.0 kW Heating Output 170.6 MBtuh Humidifier 57.2 gpd Leaving Air Temp 70.0 °F Actual Heating Fan 0 cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Htg Clg Inside db CF) 70 75 Inside RH (%) - 50 In, side wb ff) - 63 Design TD ff) 27 12 Cooling Equipment Make Trane (2 ea. 10 Ton Split) Model TTA12044 Type Split AC COP / EER / SEER 12.2 Sensible Cooling 164.7 MBtuh Latent Cooling 70.6 MBtuh Total Cooling 235.4 MBtuh Leaving Air Temp 55.0 °F Actual Cooling Fan 8000 cfm AHU 9 and 10 PROPCV BLOWTHRU 80.0 % 0.5 in H2O NAME Area I Heat I Sensible I I Latent I Htg I Clg I Time ftZ Loss Gain Gain cfm cfm Upholstery Shop I 9130 I 142247 I 164748 I I 56182 I 01 8000I Aug 1900 LDT AHU 9 and 10 9130 142247 164748 I ! 56182 1 01 8000 1 Aug 1900 LDT W�gr11�01r' Ri ht-Suite® Universal 2019 19.0.09 RSU25198 ...torylPursuit Boat Factory Reduced 7.23.2019.rup Calc = MN5 Front Door faces: E 2019-Jul-23 08:13:08 Page 8