St Lucie February 14, 2018 Kenny Wortz Kenny.Wortz@nucor.com RECEIVED JUL2019 S-r. Lucie County, Permitting Subject: Third Party Inspection for Products Inspected Under Florida Quality Assurance Expiration: February 14, 2021 Order Number: 12179840 I This letter is to confirm that America Buildings Company., has an agreement with UL LLC to conduct audits at your plant to verify Florida Quality Assurance requirements at the following location(s): S FL Product Approval Number Manufacturer/Product Name Location FL-704, FL705, FL4813, FL6961, and FL7709 AMERICAN BUILDINGS CO 1150 STATE DOCKS RD EUFAULA AL 36072 Quality Control System and Products to be inspected for compliance with manufacturer's quality documentation, and Florida Product Approval Reports. A minimum of (2) inspections per year Will be conducted. Please call us if you have any questions. Sincerely, UL LLC Kanchi Agrawala-Dokania Project Handler 1 1285 Old Walt Whitman Road Melville, NY 11747 Phone — 631-546-2458 Kanchi.Agrawala-Dokania@ul.com **Department of Community Affairs inspection agreement. UL,Intematlorwl, LLC.: 333 Pfinbsten 00a-d' Nai[hbraok, IL 606.6�2095 USA T. 847.272,88o0 /F: 847.272.8129 / W: ULcom REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNT( BOCC will be immediately notified upon termination of the FILE COPS' i ,f TGKX.93 - Roof Deck Constructions Page 1 of 6 u� ONLINE CERTIFICATIONS CIRECTORY Construction No. 93 TGKX.93 Roof Deck Constructions Page Bottom Design/System/Construction/Assembly Usage Disclaimer • Authorities Having Jurisdiction should b I consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products pare developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are Clonsidered Certified. Roof Deck Constructions Construction No. 93 July 14, 2017 Uplift — Class 90 Fire Not Investigated LL �N 2. I" http://database.ul.com/cgi-binIXYV/templateALISEXT/1 FRAME/showpage.html?name=T... 8/29/2017 TGKX.93 - Roof Deck 2a http://database.ul.com/egi-bin/XYV Page 2 of 6 SEXT/ 1 FRAME/showpage.html?name=T... 8/29/2017 I TQ KX.93 - Roof Deck Constructions tionsJ. Page 3 of 6 00 VA& si Z .. ........... -..- V. 1. Metal Roof Deck Panels* — No. 24 MSG min gauge coated steel. Panels continuous over two or more spans. Panels adjacent ce" �o be joined at side ribs by snapping a( 't interlocking sides together. Mechanical seaming operation optional for "Standing Seam H" panel and required fo'r "Standing Seam 360" panel. End laps to occur over purlins with panels overlapped 6 in. with laps centered over' urlin upper flange. A line of sealant may be used at panel end laps and side joints. r AMERICAN BUILDINGS CO (View Classification) — "Standing Seam III' or "Standing Seam 360" KIRBY BUILDING SYSTEMS MISSISSIPPI LLC (View Classification) — Shur-Lok Snap or Shur-Lok 360 KIRBY BUILDING SYSTEMS INC (View Classification) — "Standing Seam 360" 1 http://database.ul.com/egi-bin/XYV/tempidte/LISEXT/IFRAME/showpage.html?name=T... 8/29/2017 TGKX.93 - Roof Deck Constructions Page 4 of 6 1A. Building Units* — (Optional) Translucent, glass fiber reinforced plastic panels with metal rib sides. Plastic thickness nominal 1/16 in. formed to basic configuration of metal panels. A lower skin is attached to the upper skin using an adhesive. A foamed plastic is located between the skins. Panels continuous over two or more spans. AMERICAN BUILDINGS CO View Classification — "Standing Seam II Skylight or Standing Seam 360 Skylight F & F INDUSTRIES (View Classiflcation) — "SKY-BRITE" KIRBY BUILDING SYSTEMS MISSISSIPPI LLC (View Classification) — Rooflite Snap Skylight or Rooflite 360 Skylight KIRBY BUILDING SYSTEMS INC (View Classification) — "Standing Seam 360 Skylight" 1B. Building Units* (Integratl d Prismatic Skylight) — (Optional) — Prefabricated assemblies of formed polycarbonate lens and perforated 24 MSG Classified Metal Roof Deck Panel (Item 1). Panel continuous over two or more spans. AMERICAN BUILDINGS CO (View Classification) — "Standing Seam II Integrated Prismatic Skylight" or "Standing Seam 360 Integrated Prismatic Skylighq" KIRBY BUILDING SYSTEMS INC (View Classification) — "Standing Seam 360 (SS360) Skylight" 2. Roof Deck Fasteners* — (Panel Clips) — No. 22 MSG min gauge coated steel. Min width 3 in., max height 3 in. To be used when no spacer block (Item 413) is used or when no compressible blanket insulation (Item 4C) is used. AMERICAN BUILDINGS CO (View Classification) — "Standing Seam II Panel Clip or Standing Seam 360 Panel Clips." KIRBY BUILDING SYSTEMS MISSISSIPPI LLC (View Classification) — Shur-Lok Snap Panel Clips or Shur-Lok 360 Panel Clips KIRBY BUILDING SYSTEMS INC (View Classification) — "Standing Seam 360 Panel Clips" 2A. Roof Deck Fasteners* — (Panel Clips) — Alternate — Same as Item 2 with max height to be 4 in. To be used with spacer block — (Item 4B). or when [IIner panel (Item 8) is used. AMERICAN BUILDINGS CO (View Classification) — "Standing Seam Expansion and Contraction Clip" or "Standing Seam II Panel Clip" or "Standing Seam 360 Panel Clip" • CBC STEEL BUILDINGS (View Classification) — SS-24 Panel Clips or MS-24 Panel Clips KIRBY BUILDING SYSTEMS MISSII SIPPI LLC (View Classification) — "Shur-Lok Snap Panel Clips"or "Shur-Lok 360 Panel Clips" KIRBY BUILDING SYSTEMS INC (View Classification) — "Standing Seam 360 Panel Clips" 2a. Roof Deck Fasteners* — (Not shown) — Two piece clip. Upper tab aluminized or galvanized steel 0.033 In. thick. Base No. 12 MSG Coated steel. Min. height 3-3/16 in. (nom) when no spacer block is used (Item 4B). Max height 4-3/16 in. (nom) when spacer block (Item 4B)'or when liner panel (Item 8) is used. AMERICAN BUILDINGS CO (View Classification) — "Standing Seam 360 Clips" KIRBY BUILDING SYSTEMS MISSISSIPPI LLC (View Classification) — "Shur-Lok 360 Panel Clips" 2B. Panel Clip Bearing Plate — Used with rigid insulation. Located under the Roof Deck Fasteners (Item 2, 2a or 2A), over rigid insulation (Item 4A); 5-1/2 in. Isquare, fabricated from 0.043 in. thick min coated steel. 3. Fasteners — (Screws) — Fasteners, uIsed to attach panel clips (Item 2, 2a or 2A) to purlins when using compressible blanket insulation to be No. 12-14 by 1-1%4 in. min. self -drilling, self -tapping, hex -head, plated steel screws. Length to be http://database.ul.com/cgi-binIXYVItempt',�telLISEXT/1 FRAMElshowpage.html?name=T... 8/29/2017 TGKX.93 - Roof Deck Constru itions I I I Page 5 of 6 1-1/4 in. min. for insulation up to 3 in. and 1-1/2 in. min. for insulation over 3 in. thick or when using thermal spacers (Item 413). Two fasteners per'clip inserted into preformed holes to be used. Fasteners used to attach the panel clips (Item 2, 2a or 2A) to the purlins when using rigid insulation (Item 4A) to be same type. Length to vary with thickness of rigid insulation with min penetration to be 3/4 in. Two fasteners per clip to be used inserted into guide holes. Fasteners used to attach panel clips (Item 2, 2a or 2A) to purlins when using liner panel (Item 8) to be No. 12-14 self - drilling, self -tapping, hex -head plated steel screws. Min length to be equal to combined thickness of liner panel depth and foamed plastic thickness plus 5/4 in. Two fasteners per clip to be used inserted into guide holes. Fasteners used to attach liner Ranel to purlins to be No. 12-14 by 1 in. min. long self -drilling, self -tapping, hex -head, plated steel screws with a separate 1/2 in. OD steel washer and a neoprene sealing washer. Spacing to be 12 in. OC. Fasteners used at liner panel side laps to be No. 14 by 3/4 in. min. long, Type A plated steel screws with a separate 9/16 in. OD steel washer and a bonded neoprene sealing washer. Spacing to be 24 in. OC. Spacing at end laps to be in a 3I-4-4-4-3 in, pattern driven through optional upper strap into lower plate (Item 6). Pattern to be 2-3/4-2-1/4-2-7/8-2-1/4-2-7/8-2-1/4-2-3/4 when optional end lap strap not used. For panel clips and end lap connections: As an alternate fastener, No. 1/4-14 by 1 in. min. Type A plated steel screws with a separate 9/16 in. OD steel washer and a bonded neoprene sealing washer may be used. Pilot holes to be 3/16 in. diam. I Or: No. 14-14 by 1 in, min. Type AB self -drilling, self -tapping, hex -head, plated steel screws with a separate 1/2 in. OD formed steel washer and a separate neoprene sealing washer may be used. Spacing to be same for all types. 3A. Fasteners used to attach the liner panels (Item 8A) to the purlins to be No. 12-14 by 1 in. min. long self -drilling, self - tapping, hex head plated steel screws. (Liner panel to joists use No. 12-24 by 7/8 in, min. long self -drilling, self -tapping, hex head plated steel screws). Spacing of fasteners to purlins or joists to be 12 in. O.C. at intermediate supports. Fasteners spaced at 6 in. OC. at liner panel end laps. Fasteners used at liner panel side laps to be No. 12-14 by 7/8 in. min. long hex head plated steel stitch screws. Spacing of liner panel side lap fasteners to be max 30 in, when liner panel supports are 5 ft-0 in. OC. and max 36 in. OC for 6 ft -6 in. OC or 6 ft -0 in. OC support spacing. 4. Insulation — (Optional) — Any compressible blanket insulation 8 in. max thickness before compression. 4A. Foamed Plastic* — (Rigid Insulation)(Optional) — Max thickness 8 in. supplied in 4 ft widths. 4B. Spacer Block — (Optional) I Used with compressible insulation (Item 4) only — 3 in. by 24 in. by 1 In. thick polystyrene foam. 4C. Insulation — Used when liner, panel (Item 8) is used. Any compressible blanket insulation 1 in. max. thickness before compression. Located between metal roof deck panel (Item 1) and foamed plastic (Item 4A). 4D. Insulation* — (Optional) - R gid Type (Foamed Plastic) — Supplied in 4 ft wide sheets; min thickness 1/2 in., max thickness 8 in. THE DOW CHEMICAL CO (View Classification) — Types Thermax Sheathing, Thermax Light Duty Insulation, Thermax Heavy Duty Insulation, Thermax Metal Building Board, Thermax White Finish Insulation, Thermax ci Exterior Insulation, Thermax XARMOR, Thermax IH Insulation, Type Thermax Plus Liner Panel and Thermax Heavy Duty Plus (HDP) 5. Purlin — No. 16 MSG min gauge steel (50,000 psi min yield strength) or Type H or J open web joists. Spacing to be max. 60-3/16 in. 5A. Purlins — When liner Panel (Item 8A) used No. 16 MSG minimum gauge steel (50,000 psi minimum yield strength) or hot rolled shapes or open web joists. Spacing - For No. 16 minimum gauge steel. For all classes - 60 in. maximum Spacing - For open web joists or hol rolled shapes. For Class 90- 78 in, maximum (1.5B Deck) 72 in. maximum (1.5F Deck). 6. End Lap Strap (Optional) and Plate — (Not shown) — Lower plate used at the end lap to be 12-1/2 in. long and approximately the full panel width, fabricated from 0.051 in. thick coated steel. Upper strap to be 1-1/2 in. long and approximately the full panel width. Optional upper strap fabricated from 0.122 in. thick aluminum and to have eight guide holes for screw fasteners. Both piece $ formed to the general profile of the panels with lower plate to have three guide holes. 7. Insulation Trim — (Not shown) —' Used at skylight location, (see Item 1A) to consist of a lower angle having a 1-9/16 in. wide horizontal leg and a 1 in. leg slanted to a 50 degree angle. Fabricated from 0.050 in. thick coated steel. Upper angle to have a 1-1/8 in. horizontal leg and a 9/16 in. thick leg slanted to a 50 degree angle. Fabricated from 0.026 in. thick coated steel. 8. Liner Panel — (Optional) — No. 26 MSG min thickness coated steel depth 3/4 in., pitch 6 in., or 1-3/16 in, depth with major ribs located 12 in. O/C. and 3/32 in, deep minor ribs located 3-1/2 in. O/C. in the flat section of panel, width 36 in. Sides overlapped one corrugation. End, lap width min. 2 in., located over purlins. 8A. Liner Panel — 1.5B Deck (Panels 136 in, wide and 1-1/2 in, deep with 3-1/2 in. wide crests spaced 6 in. O.C) or 1.SF Deck (Panels 36 in, wide and 1-1/2 in. ldeep with 4-1/4 in. wide crests spaced 6 in. O.C) Panels fabricated from No. 22 MSG thick steel having a yield strengtl) of 33,000 psi minimum. 8B. Liner Panel — Min thickness No. 22 MSG coated steel (33,000 PSI min yield strength). Min depth 1-1/2, max pitch 6 in. fabricated to various profiles. Fastened to supports (Item 9) with fastener type and spacing per liner panel manufacturer's instructions for uplift loading. 9. Supports (Not Shown) — Used to support liner panels (Item 8B), to be cold formed or hot rolled sections. Gauge, yield strength and spacing to be per liner panel manufacturer's specifications for uplift loading. Refer to General Information, Roof Deck Constructions, (Roofing Materials and Systems Directory) for Items not evaluated. http://database.ul.com/egi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=T... 8/29/2017 TGKX.93 - Roof Deck Page 6 of 6 * Indicates such products shall Last Updated on 2017-07-14 Ouestions? The appearance of a company's name or under UUs Follow -Up Service. Only those Service. Always look for the Mark on the the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Terms of Use Page Too ©2017ULLLC ict in this database does not in itself assure that products so identified have been manufactured ucts bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulationlof the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to Ithe extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2017 UL LLC". http://database.ul.com/cgi-bin/XI'V/template/LISEXT/l FRAME/showpage.html?name=T.. 8/29/2017