Loading...
HomeMy WebLinkAboutGENERATORRECEIVE 5—] GENERAC 1; 20 1 c r /22 - duct G—�ianCy, Permitting GUd�RDIANtlO SERIES /2 2 k V4 SCNEL Residential Standby Generators BY Air -Cooled Gas Engine ftucleftidv INCLUDES: Standby Power Rating ® True PowerT" Electrical Technology Models G 07036-0, G007037-0 (Aluminum - Bisque) -16 kW 60 Hz © Two Line LCD Multilingual Digital EvolutionT" Controller (English/Spanish/ Model G007035-0 (Aluminum - Bisque) -16 kW 60 Hz French/Portuguese) Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G( 07043-1, G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz ® Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. _ter-{ rr See Page 4 for Details. 4) Electronic Governor 0 System Status & Maintenance Interval LED Indicators - 0 Sound Attenuated Enclosure _ - ® Flexible Fuel Line Connector ® Direct -To -Dirt Composite Mounting Pad ® Natural Gas or LP Gas Operation lus QU 6 5 Year Limited Warranty Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified In • Capability to be installed within 18" (457 mm) on the USA only. of a building* *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE ENGINE DESIGN a RIGOROUS TESTING are at the heart of Generac's O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible. Generac's G-Force engine This state-of-the-art power maximizing regulation system is standard on lineup offers added peace of mind and reliability for when you need it the most. The all Generac models. it provides optimized FAST RESPONSE to changing G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by extended run times in high temperatures and extreme operating conditions. electronically torque -matching the surge loads to the engine. Digital voltage regulation at _0 O TRUE POWER— ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer form produce less than 5% Total Harmonic Distortion for utility quality power. This allows network provides parts and service know-how for the entire unit, from the confident operation of sensitive electronic equipment and micro -chip based appliances, engine to the smallest electronic component. such as variable speed HVAC systems. O TEST CRITERIA: OI GENERAC TRANSFER SWITCHES: Long life and reliability are V PROTOTYPE TESTED d NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer d SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY systems and controls for total system compatibility. GENERAC LL PROMISE •BuglN M, USA using domain. and"o "gn pail. GleiNERAC' 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls . Rigid construction and added'durabijity providd%ng engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all,vifal:6'earings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) , • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution'"" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication In any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System • 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. ® Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. 16/20/22 kW Genermor Model Rated Maximum Continuous Power Capacity (NG) -• - Rated Maximum Continuous Load Current- 240 Volts (LP/NG) Total Harmpnic Dtstarhon - • ' _ Main Line Circuit Breaker Phase Number of Rotor Pales Rated A FC erFC gpenCy` - .' ;- - •�' ' � `� ' " Power Factor Battery Aegwrement (not Included)' ' -- ' Unit Weight (lb/kg) 'Dimensions (Lk�WzHj iNmrn � _ _ - _• __�� __ __ Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load** 3ound�output m dB(A) at 23 It (7 m) with generator in Ouiet Testt Iew speed rizercise'mode" Exercise duration specifications G007035-0, G007036-0, G007038-0, 0007039.0 G007042.1, 6007043-1 G007037-0 (16 kW) (20 ItW) (22 kW) 16,000.Wa0s:1 .; 20,000 Watts •• . 22,000 16,000 Watts` 18,000 Watts* 19,500 66.6/66.6 83.3f/5 91.6/881.3 Less thzn b' Less than 59S _ Less than 5%: -. -._.�__._.___--. 70 Amp 100 Amp _ .: 100 Amp 60 Hz' y 60"Hz • 60Hz 1.0 1.0 1.0 �';c�12,Volts Group26R 540,CCA Minimum ar.Gratip 35AGM 650 CCAMmimum 406/186 448/203 466/211 ] 48 x 25 z29/1218 z 638 x 732 - 66 58 5 min 5 min 5 min Engine Type of Engine Nbmbel a(Cyhn_ders � • . - Displacement _ Cybnde� Block _ _.___ ._ __ _. __.---•— - - - - _ Valve Arrangement :IgnitionSy"stem Governor System •ComPresstan Ratto� . ' ,�• ::' • _ -• '�• Stater OifCapacitylncludingFilter : Operating rpm rue{ Cepsumptibn• ' Natuial Gas;"' ft_'/hr (rna/hr),, .� ,•` - • - Ligriid Propane: =: ft3/hr (gal/tir) [Vfir]' 1/2. Load:" Note: Fuel pipe must be sfzed far full load. Required fuel -pressure to generator fuel inlet at all load ranges -3, Controls 2-Line Plain Text Multilingual LC_D_ Display _ Manual Ready to Ru Maintenance Messages Engine�RbnHou�s lndtdatioh __ _ _— 5� t�•�- _�_ Programmable start delay between 2-1500 seconds UUhlyVoltage Loss/Retdrn io Ufffify Adlustahle (Brownout Settliigf ;w; �^ Future Set Capable Exerciser/Exercise Set Error Warning y-- lAlarmMairiten�ceLogsr:_ Engine StartSequence _ .------..._..--------- Smart Battery Charger ['ChargertFault/Mlssing AG. dming Low Battery/Battery Problem Protection and Battery Cond;hon Indfoation utamalfc.Vol(age Regulation with Over and Under Voltage Protection Under-Frequency/Overload/Stepper Overcurrenl Protection Safety Fuseii/Fuse problem Protectidn` = »,__..__ Automatic Low Oil Pressure/High Oil Temperature ed Shutdown_ { OvercranWQye�spe(@ 72 Hz)/rpm Sen_se Loss_ S_huldoi_vn ' __. _ High Engine Temperature Shutdown lniernal FaulVlncorrecfWiring Protecbori Common External Fault Capability `Fieltl,Upgradable Firmware - `" _ GENERAL G-Force 1000 Series 2. . 999 cc 999 cc 999 cc •`=`-•;;�Aluminum�w/•CastlronSleeve_-_-_- •- - _ --__ _ Overhead Valve — T Overhead Valve - ~ Overhead Valve So[ttl-stat_e_Q9 gn_e_b.....^ _ Sol ds(zteW'Magnef0 , _ -Solid-sta(e.w/ Magneto -Electronic Electronic Electronic 9:5:1 12 Vdc 12 Vdc 12 Vdc Apprpz 1 9 qUi 8 L _ _ _APProx�1 3,600 3,600 3,600 (5.78) ` - ' . : 226 (6.46) — :.,: 301 (8.52) ' 327 (9.26) , 91.6 (2.52119.53], '86 (2.37) [8.99] • 92 (2.53) [9.57] (7-13 mm mercury) for natural gas,10-121 water column (19-22 mm mercury) r ma/hrx 37.26 ING) Simple user interface for ease of operation. _ Automatic Sladon Ulilityailure7 day exerciser: Start with starter control, unit stays on. If utility fails, transfer to load takes place. __ _Stops unit Power is,removed:_Conti and charger still operate.71 _ Standard _ _ Standaid Standard (programmable by dealer only) WWI W1 90216 V Standard 50 Events Each Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). ;, Y Startercanore engage�unhl 5 sec after engine.has slapped_ standard_ 17 Standard Standard- . Standard ...._Standard j Standard _ Standard Standard Standard Standard Standard —Sound levels are taken from the front of the generator. Sound levels taken from olhersides of the generator maybe higher depending on installation parameters. Rating definitions -Standby; Applicable forsupplying emergency power forlhe duration of the utility power outage. No overload capability is available for this rating. (All ratings In accordance with SS5514, IS03046 and OIN6271). ' Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine powerand condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304 6 meters) above sea level; and also vial decrease about 1 percent for each 6 "C (10 *F) above 16 °C (60 °F). 16/20/22 kW switch options Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100 equipment rated, bath inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. s Main contacts are silver plated or silver alloy t0 resist welding and sticking. • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width Hi H2 W1 W2 Depth in 26.75 30.1 10,5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 2/0-#14 Service Rated Swart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAG),loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, bath inductive and resis- tive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240, is Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 1 26.75 30.1 10.5 13.5 6.91 mm 1 679.4 764.3 266.7 343.0 175.4 Model G007036-0 (16kW) " 2 i Current Rating (Amps) 100 �Volfage Aabn (VAC)' �-�- - 120/24C'iH = f Utility Voltage Monitor (Fixed)* -Pick-up 80% -Dropout 65% 1Reiii(n t0 Utiliy, , ___ E , apprax ,15 sec , r Exercises bi-weekly for 5 minutes*t Standard Total Circuits Available 24 Tande`mBrreeakerCaWabitilies';- _ _ Circuit Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly L13m1i Model G007037-0 (16 kW)/GO07039-0 (20 kW)/ G007043-0 (22 kW) No: of P01es :. . _ . 2 rri. Current Rating (Amps) 200 Utility Voltage Monitor (Fixed)* -Pick-up 80% -Dropout 65% ;Aetum to ulllttg =. _ + fw . `j?PProx 13 si s: ' ' - Exercises hi -weekly for 5 minutes* Standard _ Enclosure Type NEMA/UL3R tCiicbit Breaker ProleEteB Lug Range 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly wl DEPTH 12 Model #. Product Description The Wi-Fi enabled LP fuel leve itoring the LP tank's fuel level 1 G007005 0 Wi Fi LP Fuel Level Monitor unexpected power failure. Stat is in need of a refill. Generac's Mobile Link allows G006463-4 Mobile Link'" cess to an Internet connection text message when a change I B005819-0 26R Wet Cell Battery ` Every standby generator rE cell battery for use with all GE11 ERAC available accessoeaes monitor provides constant monitoring of the connected LP fuel tank. Mon-'' an important step in making sure your generator is ready to run during an s alerts are available through a free application to notify when your LP tank: ou to check the status of your generator from anywhere that you have ac-; from a PC or with any smart device. You will even be notified via e-mail or: 1 the generator's status occurs. Available in the U,S, only. G007101-0 'Battery Pad Warmer The pad warmer rests undert e b (Not necessary for use with AS G007102-0 : Oil Warmer warmer slips directly over the OOill G005621-D Auxiliary Transfer Switch ;The auxiliary transfer switch cant Contact Kit you may not need. Not compati l ` Fascia Base Wrap Kit ;The fascia base wrap snaps togel G007027-0 - Bisque : (Standard on 22 kW) sleek, contoured appearance as holes located in the base. If the generator enclosure is scra G005703-0.- Bisque Paint Kit Ature corrosion. The paint kit incl enclosure. 6006485-0 Scheduled Maintenance Kit Generac's scheduled maintenancE maintenance on a Generac autom G006873-0 Smart Management Module Smart Management Modules are I : (50 Amps) power management capabilities. It power management system. LEFrSIOE VIEW Dimensions shown are approximate. Refer to Installation manual for exact dimensions. 00 NOT USE tste— [ae.a W —,=7 - (485 FRONT VIEW a battery to start the system, Generac offers the recommended 26R wet Sled standby product (excluding PowerPact®). attery. Recommended for use if the temperature regularly falls below 0°F. -style batteries). oil filter. Recommended for use if the temperature regularly falls below A kit allows the transfer switch to lock out a single large electrical load with 50 amp pre -wired switches. er around the bottom of the new air cooled generators. This offers a II as offering protection from rodents and insects by covering the lifting, or damaged, it is important to touch-up the paint to protect from the necessary paint to properly maintain or touch-up a generator its provide all the hardware necessary to perform complete routine tic standby generator. sed in conjunction with the Automatic Transfer Switch to increase its )rovides additional power managementflexibility notfound in any other dimensions & -UPCs DIMENSIONS FOR INSTALLATION PURPOSES. Model UPC 0007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378• G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 0007043-0 696471070439 II G EAV eE RM�f a ' Generac Power Systems, Inc. - S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com —� ©2017 Generac Power Systems, Inc. All rights reserved. All Ispecifications are subject to change without notice. Part No. 100000001 94-F 5/3/17 I I DESCRIPTION 6'Rorec's Smart Power Management System Is designed to optimize the performance Smart Management Modules (SMM). unlike other toad management systems that de aware and operate autonomously, Frequency is the true measure of generator engine performance and does not need generator fuel type. The modules monitor the frequency (Hz) of the power being pros, threshold, the module tvlil automatically folloW a power management eive ribei to rod, ensl The modules can be set to a toad priority between 1-8 or be set in a lock out only mod@ reducing the necessary size of the generator for a more cost effective solution. 3MM SPECIFICATIONS coil GEICQ ACCESSORIES Model Go0687/3=o C@a!s USTO Of a standby generator. The system can consist of up to 8 Indtvldual end on another control device, the SMM modules am acivatly saft- factor In increased amblent temperatures, elevation changes or d by Cenerac's standby generators and It it falls below a certain that fhe generator is not overloaded. loads that Just simply do not treed to run in an outage, therefore ?ply Sourer ......... ............- ..................................................................................I V0148s............ ..............................................................................................- ............. ... .,..... . 240 VAC (tam LureColt vdaae.................... ............................... _ . Poles......... ResisllveAmps 6.5 LLookedRokrrAmps...............................................................................................................................................................-.._... ................................. ...........................au ked ...................................................................................................................' .................................................... 40 fnclosmeAaeng..................._......................................,............,................._.......... ........................t................................................................ ,,........24D�240V .. Yes ............... ................................ ...................................... .....NEMA SR ML VERA � Site Selection tD Description A Top ofgenmator B F'o t32ndolearanee ear clearance D Windows and openings 1= Existing wall Removable fence G ff0Varhe4dclearance and Preparation Or ii (1.52 m) O 5 ft (1.62 m) f n3 3 it (q.91 m) nBF i i i i AN-grfre 24. Minimum oleardistances cannot inclu, 98 in (4r 7 c rt) 7r3u7imGrTt clemnoe pe dfalate otherwise. No operable windows, cbors, oropenin the generator. One -hour fire rated walls allow closer pl Removable fence panels forservirbV c� V (z,s2 m) rllnimWn distance from any DO NOT instaa under r-rooden decks or, Cl"raftoes Comments shrubs, bushes, ortmes. IF8A"e.=6ng, labeling, and Ifeung,-uniess state orlgoil codes in the wall are PUMIfted within 6 P, (1.62 in) from any point of Merit of the generator set, Confirm before inswation, MS placed less than 3 fi (0,91 m) In front of the generator. 1101W , overhang, or projections from the wall. cturas unlM this distance is maintalned. Installation GuldelinAir-Cooled Genermors 11 I WOMor 01101csure would nit pose any ignition nearby combustibles or structures, with or with, sereice personnel response. � i31 :cif G] j� f0i new sa, , rt, WIE tW CW s0am""V Sri; 7 J30 Mp. Mk e r-oM ss F};are 2.2. Soutfrwest Research &,6fifr'te Mg Based on this testing and the requirements of N PA 37 Sec 4.1A the guidelines for Installation of the generators listed above are changed to 16 in (457 mm) fr; rn the back side of the generator to a statrOnary wa!l or building (C)- For adequate maintenance and air - ,low clearance, the area above the generator should be at least 5 ;t (1,52 m) with a Minimum of 3 tf (0.91 m) at the front and ends Of the enclosure. This Includes trees, shrubs, and bushes. Vegetation not In compliance with These clearance parameter could obstruct air flow. In addition, exhaust fumes from the generator could inhibit plant within the owner's e; `.='f S- and the instalation drawing manual for details. Automatic stare up. Disconnect utiif, power and render unit inoperable before working on unit. Failure to do so will result in death or serious injury, Asphyxia=ion. Running engines produce carbon monoxide, a colorless, odorl..ss poisonous gas. Carbon monoxide '° , Site SelWbn and Propwation to 19fte Preparation Lire ° locate the mounting area as close as possible t the transfer switch and fuel supply. Leave adequate room arourid the area for service access (check local code), and place high enocrgi, to keep rising water from reaching the generator. ° Ghoose an open space that wilt provide adequate and unobstructed ainjow, ° Place the unit so air vents won't become clogged with leaves, grass, snow, or debris. Verify that exhaust fumes will not enter any building through eaves, windows, ventilation fans, or other air intakes (see ° Select the type of base, such as —but not limited toso", gravel, or concrete, as desired or as required by local laws or codes. Verify your local requirements before selecting. ftfa4&0r1a1 Snffiolent for Level tnstaiiation ° Prepare a rectangular area approximately 51n (127 mm) deep (A) and approximately S In (152 mm) longer and wider (B) than the footprint of the generator. Verify that the surface where the generator will be mounted is oompacted, leveled, and will not erode Over time. A concrete pad can be poured if desired or required. Figure X3 Compacted Sol! or Gravel Pad avoided, wiH result in death or serious NQTS: If a concrete pad is required, follow all applicable (gg01g3, federal, state, or local codes. l I NOTE: If the generator Is not set to OFF, .h can crank and stars as soon as the battery cables are connected. if the WIRY power supply is not turned off, sparking can occur at the battery posts and cause an explosion. installation Guidelines For6D HzAir Cooled Generators 13